ML20054G252

From kanterella
Jump to navigation Jump to search
Forwards IE Insp Repts 50-498/82-04 & 50-499/82-04 on 820301-31.No Noncompliance Noted
ML20054G252
Person / Time
Site: South Texas  STP Nuclear Operating Company icon.png
Issue date: 06/08/1982
From: Madsen G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: Oprea G
HOUSTON LIGHTING & POWER CO.
Shared Package
ML20054G253 List:
References
NUDOCS 8206210318
Download: ML20054G252 (2)


See also: IR 05000498/1982004

Text

. . .

.. 4 ;_

.,.

Dockets: 50-498/82-04.

-50-499/82-04

x_

Houston Lighting and Power Company

ATTN: G. W. Oprea, Jr.

Executive Vice President-

P. O. Box 1700 '

Houston, Texas 77001

Gentlemen:

'

This refers to the inspection conducted by Mr.'W.' M. Hill and other members of

our staff during March 1982, of activities authorized by NRC' Construction

Permits CPPR-128 and 129 for the South: Texas' Project,' Units 1 and 2, and to

the discussion of our findings.with members of your staff at the conclusion

-of the inspection.

Areas examined during the inspection and our findings are discussed in'the

enclosed inspection report. Within these areas, the inspection consisted of

selective examination of procedures and representative records, interviews

with personnel, and observations-by the inspectors.

Within the scope of this inspection, no violations or deviations were

identified.

Two new unresolved items are identified in Details Section A, paragraphs 4

and 12 of this_ report.

In accordance with 10 CFR 2.790(a), a copy of this letter and the enclosures

will be placed in the 3RC Public Document Room unless you notify this office,

by telephone, within 10 days of the date of this letter and submit written

application to withhold information contained therein within 30 days of the

date of this letter. Such application must be consistent with the

requirements of 2.790(b)(1).

RRI RPS-B RP31 DRRP&f IS D V

WHill/dsm WCrossman GMadsen JGagla/ rdo E inson K frit 3ollins

5/4 /82 5/@/82 5/g\/82 5/1f/E 5/ 82 5 /82 / l /82

-

g

8206210318 820608

PDR ADOCK 05000498

G PDR , J

-- - . _ . .__

-

.

e

Houston Lighting and Power Z [.j$ JUN 1962

Company

Should you have any questions concerning this inspection, we will be pleased

to discuss them with you.

Sincerely,

roriginal Signed by:

0, C. M ADSEN

G. L. Madsen, Chief

Reactor Project Branch 1

Enclosure:

Appendix - NRC Inspection Report 50-498/82-04

50-499/82-04

bcc to DMB (IE01) bcc distrib. by RIV:

BC W. Hill

PM W. Hubacek

AE0D J. Boardman

ELD D. Tomlinson

IE FILE W. Schum

IE/RPRIB L. Martin

NRR/DHFS C. Oberg

NRR/0LB D. Breaux

RAD ASMT BR J. Roberds

RESEARCH W. Crossman

PDR:HQ D. Hunnicutt

LPDR C. Hale

NSIC TPB

NTIS RPB2

INF0 SYSTEMS

J. Collins

RIV FILE

TEXAS DEPT. OF HEALTH RESOURCES

C. Wisner

_,