y August 3, 1990 Docket-No. 50-499 ~

DISTRIBUTION i 1 Mr. Donald P. Hall Docket File;; E. Peyton-Group Vice-President, Nuclear NRC PDR G. Dick i Houston Lighting & Power Company Local PDR OGC 5 'P. O. Box 1700 D. Crutchfield E. Jordan -ft Houston, Texas 77251 B. Boger ACRS (10)

PDIV-2 R/F L. Marsh

Dear Mr. Hall:

PDIV-2 Plant File J. Wiebe '

i

SUBJECT:

PUMP AND VALVE INSERVICE TEST (IST) PLAN, REVISION 2, SOUTH I TEXAS PROJECT, UNIT 2 (TAC NO. 76174)

By letter dated January 22, 1990 (ST-HL-AE-3345) Houston Lighting and Power '

Company (HL&P) submitted the subject plan. In the lotter, HL&P stated that i the plan was the same as the Unit 1 IST plan with the exception of the stroke time criteria, which though absent for the Unit 1 plan were included in Revision 2 to the Unit 2 IST plan.

The staff reviuwed the Unit 1 IST plan and found the relief requests accept-able. The results of the review were reported in Supplement No. 5 (SSER 5) to the Safety Evaluation Report related to the operation of South Texas Project, Units 1 and 2 NUREG-0781. Similarly, the staff acceptance of the relief. l requests in the Unit 2 IST plan, subject to timely resolution of the stroke time i criteria..is reported in SSER 6 to NUREG-0781. HL&P has addressed this issue in l the subject plan. While the staff finds this acceptable, the stroke tir.e criteria need not be documented in the plan itself, if it is included elsewhere in proce- 1 dures. With this approach, changes in stroke time criteria would not require i revisions to the IST plan. Our program review is complete. However, the program.

j

- 3

, and implementation documentation should remain available onsite in the envent that

.an implementation inspection is conducted. Any revisions to the IST plans should be provided to the NRC.

Sincerely,

)

OriginalSignedByi i George F; Dick, Jr. , Project Manager Project Directorate IV-2 Division of Reactor Projects - III, IV, V and Special-Projects Office of Nuclear Reactor Regulation cc: See next page

{ d *See previous sheet for concurrence  ;

0FC  : PDIV-2/LA*  : PDIV-2/PM* : NRR:MEB*  : PDIV-2/

.............................. ......................:......... f  :...............:... ........

NAME : EPeyton  : GDick:ye  : LMarsh  : CGrime  :  :

3 ..... ..............--............................--........................----...............

f DATE : 7/25/90  : 7/25/90  : 8/2/90  :

8/g/90 OFFICIAL RECORD COPY Document Name: PUMP & VALVE INSERVICE TEST

} 4 ; ll r

QP""9963090211 DR ADOCK 0500 900803 9

- .- . 'o eL .?

$ Mr/ Donald P. Hall -

cc:

Senior Resident Inspector Jack R. Newman, Esq.

U.S. Nuclear Regulatory Commission Newman & Holtzinger, P.C.

P. O. Box 910 1615 L Street, N.W.

Bay City, Texas 77414 Washington, D.C. 20036 Mr. J. C. Lanier Licensing Representative i Director.of Generation Houston Lighting and Power Company City of Austin Electric Utility Suite 610 721 Barton Springs Road Three Metro Center Austin, Texas 78704 Bethesda, Maryland 20814 Mr. R. J. Costello Bureau,of Radiation Control Mr. M. - T. Hardt- State of Texas City Public Service Board 1101 West 49th Street P. O. Box 1771 Austin, Texas 78756 San Antonio, Texas -78296 '

Rufus S. Scott Mr. R. P. Verret Associate General Counsel Mr. D. E. Ward Houston Lighting & Power Company L Central' Power and Light Company P. O. Box 61867 l' P. O. Box 2121- Houston, Texas 77208 Corpus Christi, Texas 78403 INPO Reccrds Center 110, Circle 75 Parkway.

Atlanta, Georgia 30339-3064 Regional Administrator, Region IV U.S. Nuclear Regulatory Commission 611 Ryan Plaza Drive, Sufte 1000 l

Arlington, Texas 76011

,Mr. Joseph M. Hendrie 50 Be11 port' Lane i, Be11 port, New York 11713 I

Judge, Matagorda County Matagorda County Courthouse l

o 1700 Seventh Street Bay City, Texas 77414 l

Mr. M..A. McBurnett L . Manager, Operations Support Licensing l Houston Lighting & Power Company h P. O. Box 289 Wad: worth, Texas 77483 l

.