Responds to Re Request for Relief from ASME Code, Section Xi,Requirement to Perform VT-1 Visual Exam on Accessible Surfaces of RPV Flange Inserts (Bushings). Safety Evaluation Encl
ML20195J673
Person / Time
Site: South Texas  STP Nuclear Operating Company icon.png
Issue date: 06/17/1999
From: Gramm R
NRC (Affiliation Not Assigned)
To: Cottle W
HOUSTON LIGHTING & POWER CO.
Shared Package
ML20195J680 List:
References
TAC-MA5462, TAC-MA5463, NUDOCS 9906210080
Download: ML20195J673 (2)


Text

-

e June 17, 1999 i

Mr. William T. Cottle President and Chief Executive Officer STP Nuclear Operating Company South Texas Project Electric Generating Station P. O. Box 289 Wadsworth,TX 77483 i

SUBJECT:

SOUTH TEXAS PROJECT, UNITS 1 AND 2 -INSERVICE INSPECTION i

PROGRAM, REllEF REQUEST RR-ENG-2-5 (TAC NOS. MA5462 AND MA5463)

Dear Mr. Cottle:

By letter dated May 17,1999, STP Nuclear Operating Company (STPNOC) submitted the -

4 subject request for relief from the American Society of Mechanical Engineers Boiler and Pressure Vessel Code,Section XI, requirement to perform a VT-1 visual examination on the j

accessible surfaces of the reactor pressure vessel flange inserts (buchings). As an alternative to the visud examination, STPNOC proposed to perform a straight beam ultrasonic examination from the top surface of each insert (36 per unit).

The Nuclear Regulatory Commission (NRC) staff has reviewed the request and finds that STPNOC's proposed alternative provides an acceptable level of quality and safety, and is therefore authorized pursuant to 10 CFR 50.55a(a)l t)(i) for the second inservice inspection interval.- The staff's safety evaluation is enclosed.

Sincerely, QUGINAL SIGED BY Robert A. Gramm, Chief, Section 1 Project Directorate IV & Decommissioning y

b k ado!k 050N 498 Division of Licensing Project Management j

p PDR Office of Nuclear Reactor Regulation i

Docket Nos. 50-498 and 50-499

Enclosure:

As stated ll cc w/ encl: See next page FilF CFRTH1 P.0PY DISTRIBUTION:

OB$liketMMiId PDIV-1 Reading PUBLIC Rwelmele#GBieel+

SRichards OGC GHill (4)

DLange ACRS KBrockman, RIV

{gef y (SE only)(EGN-)

ge g t

DOCUMENT NAME: G:\\PDIV-1\\SouthTexas\\ RELA 5462.wpd To recewe a copy of the document. Indicate m the box C-Copy w/o attachment /encbsure E-Copy with attachmenvenebsure N - No copy OFFICE PDIV-1/PM, E

PDIV-D/LA' E EMCB/SC OGCn PDIV-1/SC TAlexiobk CJamerson hESullivan h1 lWh RGramh NAME DATE

[ / N/99

[ /,27 /99 0

1

/

/99 h

(n / M /99 OFFICIALVRECORD COPY

p t

i i

t South Texas, Units 1 & 2 cc:

Mr. Cornelius F. O'Keefe Mr. J. J. Sheppard, Vice President Senior Recident inspector Engineering & Technical Services U.S. Nuclear Regulatory Commission STP Nuclear Operating Company P. O. Box 910 P. O. Box 289 Bay City, TX 77414 Wadsworth,TX 77483 A. Ramirez/C. M. Canady S. M. Head, Supervisor, Licensing Cityof Austin Quality & Licensing Department Electric Utility Department STP Nuclear Operating Company 721 Barton Springs Road P. O. Box 289 Austin,TX 78704 Wadsworth, TX 77483 Mr. M. T. Hardt Office of the Governor Mr. W. C. Gunst ATTN: John Howard, Director City Public Service Board Environmental and Natural P. O. Box 1771 Resources Policy San Antonio, TX 78296 P. O. Box 12428 Austin, TX 78711 Mr. G. E. Vaughn/C. A. Johnson Central Power and Light Company Jon C. Wood P. O. Box 289 Matthews & Branscomb MailCode: N5012 One Alamo Center Wadsworth, TX 74483 106 S. St. Mary's Street, Suite 700 San Antonio, TX 78205-3692 INPO Records Center Arthur C. Tate, Director 700 Galleria Parkway Division of Compliance & Inspection Atlanta, GA 30339-3064 Bureau of Radiation Control l

Texas Department of Health Regional Administrator. Region IV 1100 West 49th Street U.S. Nuclear Regulatory Commission Austin,TX 78756 611 Ryan Plaza Drive, Suite 400 Arlington, TX 76011 Jim.Calloway Public L tility Commission of Texas D. G. Tees /R. L. Balcom Electric Industry Analysis i

Houston Lighting & Power Co.

P. O. Box 13326 P. O. Box 1700 Austin TX 78711-3326 Houston,TX 77251 Judge, Matagorda County -

Matagorda County Courthouse 1700 Seventh Street Bay City, TX 77414 Jack R. Newman, Esq.

Morgan, Lewis & Bocklus 1800 M Street, N.W.

Washington, DC 20036-5869 May 1999