Forwards Feedwater Nozzle Insp Rept for Refueling Outage RF86A,Spring 1986 & Rev 3 to NDE & I Instruction Qci 6-4, Ultrasonic Exam BWR Nozzle Inner Radius
ML20215B714
Person / Time
Site: Columbia Energy Northwest icon.png
Issue date: 12/04/1986
From: Sorensen G
WASHINGTON PUBLIC POWER SUPPLY SYSTEM
To: Martin J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
Shared Package
ML20215B717 List:
References
GO2-86-1054, NUDOCS 8612120292
Download: ML20215B714 (1)


Text

-

f.6 Washington Public Power Supply System P.O. Box 968 3000 GeorgeWashington Way Richland, Washington 99352 (509)372-5000 December 4, 1986 G02-86-1054 s Docket No. 50-397 Mr. J. B. Martin, Regional Administrator U.S. Nuclear Regulatory Commission Region V 1450 Maria Lane, Suite 210 Walnut Creek, CA 94596 1

Dear Mr. Martin:

Subject:

NUCLEAR PLANT NO. 2 WNP-2 FEEDWATER N0ZZLE INSPECTION REPORT SUBMITTAL

Reference:

NUREG-0619 "BWR Feedwater Nozzle and Control Rod Drive Line Nozzle Cracking" Attached is the Supply System's report on the WNP-2 Feedwater Nozzle examinations performed during the Spring 1986 refueling outage. This report is submitted to comply with the reporting requirements of ,

NUREG-0619, Section 4.4.3, " Reports" (reference).

If the Staff has any questions on this subject, please contact Mr. P. L.

Powell, Manager, WNP-2 Licensing.

Very truly yours, b

G. C. Sorensen, Manager Regulatory Programs DPR/ tmh Attachment cc: EG Adensam - NRC z; J0 Bradfute - NRC 32 JM Taylor - NRC = g x ,

NRC Site Inspector m r7 m m

5 b $b o<

$ $21ggg g $ $$ ;7 G

1 DD/ ,