05000254/LER-1994-015, Forwards LER 94-015-00:on 941002,single Loop Operation in Unanalyzed Condition Occurred

From kanterella
Jump to navigation Jump to search
Forwards LER 94-015-00:on 941002,single Loop Operation in Unanalyzed Condition Occurred
ML20076M664
Person / Time
Site: Quad Cities Constellation icon.png
Issue date: 11/01/1994
From: Kraft E
COMMONWEALTH EDISON CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20076M666 List:
References
STM-94-005, STM-94-5, NUDOCS 9411080203
Download: ML20076M664 (2)


LER-2094-015, Forwards LER 94-015-00:on 941002,single Loop Operation in Unanalyzed Condition Occurred
Event date:
Report date:
2542094015R00 - NRC Website

text

s C:mm:nwsalth Edis:n J/ cD Ouad Cities Nuclear Power Station

?

m";' 22710 206 Avenue North Cordova. Ilknots 61242-9740

  • Telephone 309/654 2241 stb 94-005 November 1, 1994 U.S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555

Reference:

Quad Cities Nuclear Power Station Docket Number 50-254, DPR-29, Unit One Enclosed is Licensee Event Report (LER)94-015, Revision 00, for Quad Cities Nuclear Power Plant Station.

This report is submitted in accordance with the requirements of the Code of Federal Regulations, Title 10, Part 50.73(a)(2)(ii)(A). The Licensee shall report any event or condition that resulted in the condition of the nuclear power plant, including its principal safety barriers, being seriously degraded, or that resulted in the nuclear power plant being in an unanalyzed condition that significantly compromised plant safety.

The following commitments are being made by this letter:

- Procedures associated with SLO will be revised to incorporate a minimum core flow limit as recommended by GE SIL 517. Additionally, the adequacy of tha current frequency for monitoring loop temperatures during SLO, .,nich is once per shift, will be evaluated.

- The Training Department will review the Technical Specification amendment package for SLO (Unit 1/2 - amendment 147/143) to determine the additional training for the licensed operators. The training will include the details of this event.

- The Regulatory Assurance Department will review QCAP 2300-13,

" Processing Operating License Amendments," to verify that sufficient procedural guidance exists for providing the appropriate operating license amendment information to the cognizant station departments. In addition, Technical Specification amendments from the past three years will be reviewed to determine if any procedural or training concerns exist.

- Regulatory Assurance personnel will be trained on QCAP 2300-8, " Station Operating Experience Review and Response," to ensure all Operating Experience information is sent to the Training Department for evaluation. In addition, Service Information Letters from the past three years pertaining to systems considered 'Important to Safety' will be reviewed for inclusion into the Training Program.

- All Operating Department shift personnel will be trained on QCAP 200-11,

" Heightened Level of Awareness Program." This training will emphasize when HLA briefings are required, and the prominent items that these briefings should address.

smGROO594.SW 0 801 ' = 9411080203 941101 ADOCK 05000254 -

PDR S PDR / g

9 STM-94-005 11/01/94, Pa'ge 2 For Operating Department shift personnel, the expectations for panel monitoring for the purpose of identifying abnormal indications will be clarified.

If there are any questions or comments concerning this letter, please refer them to Nick Chrissotimos, Regulatory Assurance Administrator at 309-654-2241, ext. 3100.

Respectfully.

COMMONWEALTH EDISON QUAD CITIES NUCLEAR POWER STATION

b. b. dY d1 p E. S. Kraft, Jr.

Site Vice President and Acting Station Manager ESK/TB/plm Enclosure cc: J. Schrage C. Miller INP0 Records Center NRC Region III snicas