ML20148H120

From kanterella
Jump to navigation Jump to search

Forwards Supplemental SER Re 970523 Request for Deviations from Reg Guide 1.97 Recommendations for Containment Isolation Valve Position Monitoring Instrumentation at Plant,Unit 3.Proposed Deviations Acceptable
ML20148H120
Person / Time
Site: Waterford Entergy icon.png
Issue date: 06/05/1997
From: Chandu Patel
NRC (Affiliation Not Assigned)
To: Dugger C
ENTERGY OPERATIONS, INC.
Shared Package
ML20148H124 List:
References
RTR-REGGD-01.097, RTR-REGGD-1.097 TAC-M98793, NUDOCS 9706090240
Download: ML20148H120 (3)


Text

, June 50 1997

.- l Mr. Charles M. Dugger Vice President Operations Entergy Operations, Inc.

P. O. Box B Killona, LA 70066

SUBJECT:

EMERGENCY RESPONSE CAPABILITY - CONFORMANCE TO REGULATORY GUIDE 1.97, REVISION 3 (TAC N0. M98793) 1

Dear Mr. Dugger:

l By letter dated May 23, 1997, as supplemented by letter dated May 30, 1997, Entergy Operations, Inc. requested deviations from the Regulatory Guide I.97 i recommendations for containment isolation valve position monitoring instrumentation at the Waterford Steam Electric Station, Unit 3.

The Nuclear Regulatory Commission staff has reviewed the proposed deviations and concluded that they are acceptable. Enclosure 1 is our Supplemental i Safety Evaluation Report.

Sir.cerely, j ORIGINAL SIGNED BY J. Hall for .

Chandu P. Patel, Project Manager i Project Directorate IV-1 i Division of Reactor Projects III/IV Office of Nuclear Reactor Regulation l

Docket No. 50-382 l

Enclosure:

Supplemental Safety Evaluation Report cc w/ encl: See next page DISTRIBUTION:

Docket: File PUBLIC PD4-1 r/f C. Patel ~ W. Beckner C. Hawes J. Roe T. Gwynn, RIV E. Adensam (EGA1)

,l ACRS B. Marcus J. Wermiel A Document Name: WAT98793.LTR j OFC PM/PD4-1_ ,o LA/PD4-1 HICB r"

[

NAME CPatel CHawes Of M JWehl i DATE [/(/97 [2/6/97 h/[/97 COPY /h/N0 YES/N0 [YESJNO U OFFICIAL RECORD COP F 000021 h fdh $

9706090240 970605 PDR ADOCK 05000382 l P PDR

{

I c** "*%s4 p UNITED STATES s* }

2 NUCLEAR RE'IULATORY COMMISSION WASHINGTON, D.C. 206d50001 3

o l

%f*****/ June 5, 1997 1

l l

Mr. Charles M. Dugger Vice President Operations Entergy Operations, Inc.  :

P. O. Box B  !

L Killona, LA 70066 I l

SUBJECT:

EMERGENCY RESPONSE CAPABILITY - CONFORMANCE TO REGULATGRY l l GUIDE 1.97, REVISION 3 (TAC NO. M98793) l

Dear Mr. Dugger:

l By letter dated May 23, 1997, as supplemented by letter dated May 30, 1997, ,

Entergy Operations, Inc. requested deviations from the Regulatory Guide 1.97 l recommendations for containment isolation valve position monitoring instrumentation at the Waterford Steam Electric Station, Unit 3.

l The Nuclear Regulatory Commission staff has reviewed the proposed deviations  !

and concluded that they are acceptable. Enclosure 1 is our Supplemental l Safety Evaluation Report.  ;

Sincerely, l Chandu P. Patel, Project Manager Project Directorate IV-1 Division of Reactor Projects III/IV ,

Office of Nuclear Reactor Regulation Docket No. 50-382

Enclosure:

Supplemental Safety Evaluation Report cc w/ encl: See next page

\

  • Mr.. Charles M. Dugger )

i Entergy Operations, Inc. Waterford 3 i cc: ,

)

Administrator Regional Administrator, Region IV Louisiana Radiation Protection Division U.S. Nuclear Regulatory Commission l Post Office Box 82135 611 Ryan Plaza Drive, Suite 1000 l Baton Rouge, LA 70884-2135 Arlington, TX 76011 l Vice President, Operations- Resident Inspector /Waterford NPS Support Post Office Box 822 Entergy Operations, Inc. Killona, LA 70066 P. O. Box 31995

- Jackson, MS 39286 Parish President Council St. Charles Parish Director P. O. Box 302 Nuclear Safety & Regulatory Affairs Hahnville, LA 70057 Entergy Operations, Inc.

P. O. Box B Executive Vice-President Killona, LA 70066. and Chief Operating Officer Entergy Operations, Inc.

Wise, Carter, Child & Caraway P. O. Box 31995 P. 0.' Box 651 Jackson, MS 39286-1995 Jackson, MS 39205

- Chairman General Manager Plant Operations Louisiana Public Service Commission Entergy Operations, Inc. One American Place, Suite 1630 P. O. Box B Baton Rouge, LA 70825-1697 Killona, LA 70066 i

l Licensing Manager i Entergy Operations, Inc.

P. O. Box B Killona, LA 70066 Winston & Strawn-1400 L Street, N.W.

Washington, DC 20005-3502 i i

I i

i 4

J . +