IR 05000302/1984023

From kanterella
Jump to navigation Jump to search
Safeguards Insp Rept 50-302/84-23 on 840812-16.Violations Noted:Failure to Implement & Fully Maintain Provisions of Approved Physical Security Plan Re Protection of Vital Equipment.Details Withheld (Ref 10CFR73.21)
ML20128Q389
Person / Time
Site: Crystal River Duke energy icon.png
Issue date: 01/02/1985
From: Mcguire D, Moore D
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
Shared Package
ML20128Q383 List:
References
50-302-84-23, EA-84-104, NUDOCS 8507260672
Download: ML20128Q389 (1)


Text

-

,

SAFEGllAPJSAFORMATION

--

=...

..g#o NUCLEAR REGULATORY COMMISSION [ o REGION ll 5 $ 101 M ARIETTA STREET, *

o, 8 ATLANTA, GEORGIA 30303

. . . . * *#

JAN 01985 Report No. 50-302/84-23 Licensee: Florida Power Corporation P. O. Box 14042 St. Petersburg, FL 33733 Docket No. 50-302 License No. DPR-72 l l

Facility Name: Crystal River 3 Intpection Date: August 12-16, 1984

.- Inspect $9t ,C lln)fS D..E N oore, P 'ical Security Inspector Dhts Signed i Approved'by: D V /2

-

, D. R. McGuire, Chief, Physical Security Section Dat4 S'igned Nuclear Materials Safety and Safeguards Branch

,

Division of Radiation Safety and Safeguards SUMMARY Scope: . This ' routine unannounced inspection entailed 32 inspector-hours on site .(6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> on .>backshift) inspecting: security organization personnel / response; testing and maintenance; physical barriers-vital areas; security system power supply; access control personnel / packages / vehicles; detection aids-vital areas; and independent inspection effort. Additionally, 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> were devoted to allegation followup concerning another NRC licensed facilit Results: Two violations of regulatory requirements were identified:

Failure to implement and fully maintain provisions of the approved physical security plan concerning the protection of vital equipmen Inadequate vital area physical barrie o -

%

"