AECM-84-0173, Forwards Application for Amend to License NPF-13,changing Tech Specs Re Automatic Depressurization Sys Valve Operability Requirements to Achieve Consistency Between Tech Specs & Design & Accident Analyses

From kanterella
Revision as of 13:37, 25 September 2022 by StriderTol (talk | contribs) (StriderTol Bot insert)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Forwards Application for Amend to License NPF-13,changing Tech Specs Re Automatic Depressurization Sys Valve Operability Requirements to Achieve Consistency Between Tech Specs & Design & Accident Analyses
ML20087J780
Person / Time
Site: Grand Gulf Entergy icon.png
Issue date: 03/20/1984
From: Mcgaughy J
MISSISSIPPI POWER & LIGHT CO.
To: Harold Denton
Office of Nuclear Reactor Regulation
Shared Package
ML20087J781 List:
References
AECM-84-0173, AECM-84-173, NUDOCS 8403230084
Download: ML20087J780 (2)


Text

<

MISSISSIPPI POWER & LIGHT COMPANY Helping Build Mississippi P. O. B OX 1640. J AC K S O N, MIS SIS SIP PI 3 9 2 05 March 20, 1984

"* Lv 7278.U"' #

U.S. Nuclear Regulatory Commission Office of Nuclear Reactor Regulation Washington, D.C. 20555 Attention: Mr. Harold R. Denton, Director

Dear Mr. Denton:

SUBJECT:

Grand Gulf Nuclear Station Unit 1 Docket No. 50-416 License No. NPF-13 File 0260/0840/L-860.0 Proposed Amendment to the Operating License (PCOL-84/02)

AECM-84/0173 In accordance with the provisions of 10 CFR 50.59 and 10 CFR 50.90, Mississippi Power & Light (MP&L) requests an amendment to License NPF-13, for Grand Gulf Nuclear Station (GGNS) Unit 1.

In accordance with provisions of 10 CFR 50.30, threa (3) signed originals and forty (40) copies of the requested amendment are enclosed.

The attachment provides the complete technical justification and discussion to support the requested amendment. This amendment has been reviewed and accepted Dy the Plant Safety Review Committee (PSRC) and the Safety Review Committee (SRC).

In accordance with the requirements of 10 CFR 170.22, we have determined that the proposed amendment includes one safety issue, Item 1, and one issue that is considered to be administrative in nature, Item

2. Based on the guidance provided by the Project Manager (NRC), we have determined that the total fee is $5,200. As discussed with Mr. L. L.

Kintner of your staff on March 20, 1984, a remittance of $5,200 will be provided to your office within one week of the date of this letter.

Y urs traly,

& A JPM:lm Attachments: GGNS PLOL-84/02 cc: (See Next Page) 8403230084 840320 l p DR ADOCK 05000416 PDR y g

(

DM1 l Member Middle South Utilities System

AECM-84/0173 MIC'I!CCIPPI POWER Q LICHT COMPANY Page 2 cc: Mr. J. B. Richard (w/o)

Mr. R. B. McGehee (w/o)

Mr. T. B. Conner (w/o)

Mr. G. B. Taylor (w/o) i Mr. Richard C. DeYoung, Director (w/a)

Office of Inspection & Enforcement U.S. Nuclear Regulatory Commission

, Washington, D.C. 20555 Mr. J. P. O'Reilly, Regional Administrator (w/a)

U.S. Nuclear Regulatory Commission Region II 101 Marietta St., N.W., Suite 2900 Atlanta, Georgia 30303 Dr. Alton B. Cobb (w/a)

State Health Officer State Board of Health Box 1700 Jackson, Mississippi 39205 f