Forwards Insp Rept 50-312/85-26 on 850826-30.No Significant Deficiencies or Violations Identified.Potential Inconsistencies in Emergency Plan & Implementing Procedures Re Protective Action Recommendations Noted
ML20198C298
Person / Time
Site: Rancho Seco
Issue date: 10/23/1985
From: Wenslawski F
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
To: Reinaldo Rodriguez
SACRAMENTO MUNICIPAL UTILITY DISTRICT
Shared Package
ML20198C304 List:
References
NUDOCS 8511120043
Download: ML20198C298 (2)


See also: IR 05000312/1985026

Text

_

[. .. -

gg

OCT 231985

Docket No. 50-312

Sacramento Municipal Utility District

7. P. O. Box 15830

Sacramento, California 95813

Attention: Mr. R. J. Rodriguez

Assistant General Manager, Nuclear

Gentlemen:

Subject: hTC Inspection

This refers to the inspection conducted by Mr. K. M. Prendergast, Team Leader,

and others of this office on August 26-30, 1985, of activities authorized by

NRC License No. DPR-54, and to the discussion of our findings held by

Mr. Prendergast with Mr. R. J. Rodriguez and other members of your staf f at

the conclusion of the inspection.

Areas examined during this inspection are described in the enclosed inspection

report. Within these areas, the inspection consisted of selective

examinations of procedures and representative records, i'.terviews with

personnel, and observations by the inspectors.

No significant deficiencies or violations of h3C requirements were identified

within the scope of this inspection. However, during this inspection we

became aware of potential inconsistencies in the Emergency Plan and the

associated implementing procedure regarding protective action recommendations

(PARS). You should review this area to assure that the responsibilities for

making timely and appropriate PARS are unambiguously defined. In addition,

the results of this inspection indicated that the Emerger.cy Plan and

implementing procedures are still not reflective of the ct rrent training

program which is newly implemented. We would urge an upgrade to the Emergency

Plan and implementing procedures as expeditiously as possible .o insure

program consistency.

In accordance with 10 CFR 2.790(a), a copy of this letter and the enclosure

will be placed in the NRC Public Doct. ment Room.

I

\

8511120043 851023 -

PDR ADOCK 05000312

G PDR h

L__

'

.

.

Sacramento Municipal Utility District -2-

Should you have any questions concerning this inspection, we will be glad to

discuss them with you.

Sincerely,

Original signad W

F. A. Wembwski

F. A. Wenslawski, Chief

Emergency Preparedness and

Radiological Protection Branch

Enclosure:

Inspection Report

No. 50-312/85-26

cc:

L. G. Schwieger, SMUD

P. Oubre' , SMLU)

State of CA

FEMA, Region IX

bec:

RSB/ Document Control Desk (RIDS)

Mr. J. Martin

Mr. B. Faulkenberry

G. Cook

Resident Inspector

R. Dodds

D. Matthews, EPB:IE

RV gd

KPrenderga M

M

RFish

A'

FWenslawski

10/ 22./85 \OlL2go/g/85 10/p.3/85