Forwards Amend 105 to License DPR-54 & Safety Evaluation. Amend Clarifies Operational Mode of Applicability of Tech Spec 3.4 & Definition of Auxiliary Feedwater Train & Revises Frequency for Verifying Auxiliary Feedwater Sys Flow Path
ML20247K706
Person / Time
Site: Rancho Seco
Issue date: 05/23/1989
From: Reynolds S
Office of Nuclear Reactor Regulation
To: Firlit J
SACRAMENTO MUNICIPAL UTILITY DISTRICT
Shared Package
ML20247K709 List:
References
TAC-72046, NUDOCS 8906010367
Download: ML20247K706 (3)


Text

-, - _ _ - -.

May 23,1989 9

Docket No.: 50-312 DISTRIBUTION fiDocket, fiTe-Wanda Jenes tNRC'& LPDRs" EButcher JLee N GPA/PA Mr. Joe Firlit Mirgilio ARM /LFMB

. Chief Executive Office, Nuclear SReynolds ACRS (10)

Rancho Seco Nuclear Cenerating Station GKalman PDS Plant File 14440 Twin Cities Road EJordan Region V (4) l Herald, California 95638-9799 BGrimes OGC DHagan JWermiel

Dear Mr. Firlit:

IMeek(4)

SUBJECT:

AMENDMENT NO.105 TO FACILITY OPERATING LICENSE NO. DPR-54 RANCHO SEC0 NUCLEAR GENERATING STATION (TAC NO. 72046)

The Commission has issued the enclosed Amendment No. 105 to Facility Operating License No. DPR-54 for the Rancho Seco Nuclear Generating Station. This amend-ment consists of changes to the Technical Specifications (TS) in response to your application dated October 7,1988, as supplemented November 18, 1988, and March 27, 1989.

This amendment clarifies the operational mode applicability of TS 3.4 and the definition of auxiliary feedwater (AFW) train, revises the surveillance requirements and frequency of ver'fying the AFW System flow path, and revises the surveillance requirement for AFW pump testing.

A copy of our Safety Evaluation is also enclosed. Notice of Issuance will be included in the Commission's bi-weekly Federal Register notice.

Sincerely, original signed by Steven A. Reynolds, Project Manager Project Directorate V Division of Reactor Projects - III, IV, V and Special Projects

Enclosures:

1.

Amendment No. 105 to DPR-54 2.

Safety Evaluation cc w/ enclosures:

See next page I

(RSAMD72046) r i

f h/PDV DRSP/8 DRWPg NR SPLB OGC 1

DR e

SReyfwlds CMimfiah JWermeil G

on 2/89 4//o/89 y /Z6/89 4 # 7/89 f // /89 f/ / /89 0FFICIAL RECORD COPY

(

8906010367 890523 I (

PDR ADOCK 05000312 P

PDC

\\

Q Tto UNITED STATES

[;

g NUCLEAR REGULATORY COMMISSION

' 7.

  • [

WASHINGTON, D. C. 20555 May 23,1989 Docket No.:

50-312 Mr. Jce Firlit Chief Executive Officer, Nuclear Rancho Seco Nuclear Generating Station 14440 Twin Cities Road Herald, California 95638-9799

Dear Mr. Firlit:

SUBJECT:

AMENDHEriT NO.105 TO FACILITY OPERATING LICENSE NO. DPR-54 RANCHOSEC0NUCLEARGENERATINGSTATION(TACNO.72046)

The Consission has issued the enclosed Amendment No.105 to Facility Operating License No. DPR-54 for the Rancho Seco Nuclear Generating Station. This amendment consists of changes to the Technical Specifications (TS) in response to your application dated October 7, 1588, as supplemented November 18, 1988, and March 27, 1989.

This amendment clarifies the operaticaal mode applicability of TS 3.4 and the definition of auxiliary feedwatei (/JW) train, revises the seve111ance requirements and frequency of verifying the AFW System flow path, and revises the surveillance requirement for AFW pump testing.

A copy of our Safety Evaluation is also enclosed. Notice of Issuance will be included in the Comission's bi-weekly Federal Register notice.

Sincerely, i

O b

Steven A. Reynolds, Project Manager Project Directorate V Division cf Reactor Projects - III, IV, V and Special Projects

Enclosures:

1.

Amendment No. 105 to DPR-54 2.

Safety Evaluation cc w/ enclosures:

See next page

.____-________-____-____-_________a

t Mr. Joe Fir 11t Rancho Seco Nuclear Generating Chief Executive Officer, Nuc1' ear Station Rancho Seco Nuclear Generating Station 14440 Twin Cities Road Herald, California 95638-9799 Mr. David S. Kaplan, Secretary Mr. John Bartus and General Counsel Ms. JoAnne Scott Sacramento Municipal Utility Federal Energy Regulatory Comission District 825 North Capitol Street, N. E.

6201 S Street Washington, D.C.

20426 P. O. Box 15830 Sacramento, Californie 95813 Thomas A. Baxter, Esq.

Ms. Helen Hubbard Shaw, Pittman, Potts & Trowbridge P. O. Box 63 2300 N Street, N.W.

Sunol, California 94586 Washington, D.C.

20037 Mr. Steven Crunk Manager, Nuclear Licensing Sacramento Municipal Utility District Rancho Seco Nuclear Generating Station 14440 Twin Cities Road Herald, California 95638-9799 Mr. Robert B. Borsum, Licensing Representative l

Babcock & Wilcox huclear Power Division 1700 Rockvil10 Pike - Suite 525 Rockville, Maryland 20852 Resident Inspector / Rancho Seco c/o U. S. N. R. C.

14440 Twin Cities Road Herald, California 95638 Regional Administrator, Region V U.S. Nuclear Regulatory Commission 1450 Maria Lane, Suite 210 Walnut Creek, Cali"ornia 94596 Mr. Paul Szalinski, Chief Radiological Health Branch State Department of Health Services 714 P Street, Office Building #8 Sacramento, California 95814 Sacramento County Board of Supervisors 700 H Street, Suite 2450 l

Sacramento, California 95814 l

l

_a