ML20059G942

From kanterella
Jump to navigation Jump to search

Forwards Amend 115 to License DPR-54 & Safety Evaluation. Amend Revises License Condition Re Fire Protection Plan,Adds Administrative Controls to Tech Specs in Support of Fire Protection Plan & Relocates Fire Protection Requirements
ML20059G942
Person / Time
Site: Rancho Seco
Issue date: 09/10/1990
From: Reynolds S
Office of Nuclear Reactor Regulation
To: Keuter D
SACRAMENTO MUNICIPAL UTILITY DISTRICT
Shared Package
ML20059G946 List:
References
GL-86-10, GL-88-12, TAC-75565, NUDOCS 9009140068
Download: ML20059G942 (3)


Text

- _ _ - _.

+

Seirater 10,1990 i

Docket No. 50-312 Mr. Dan R. Keuter Assistant General Manager, Nuclear Rencho Seco Nuclear Generating Station 14440 Twin Cities Road Herald, California 95638-9799

Dear Mr. Keuter:

SUBJECT:

. ISSUANCE OF AMENDMENT NO.115 TO FACILITY OPERATING LICENSE NO. DPR-54 RANCHO SECO NUCLEAR GENERATING STATION (TAC NO. 75565)

The Commission has issued the enclosed Amendment No.115 ' to Facility 0)erating License No. DPR-54 for the Rancho Seco Nuclear Generating Station. T its amendment consists of changes to the license co.iditions, the Technical-Specifications, and the Fire Protection Plan in response to your application dated December 28,L1989, and supplemented March 16, 1990.

=.ne amendment revises the license condition concerning the Fire Protection Plan,addsadministrativecontrolstotheTechnicalSpecifications(TS)in support of the Fire Protection Plan and relocates the Fire Protection requirements from the TS to the Fire Protection Plan as described in Generic

-Letters 86-10 and 88-12.

The proposed USAR changes included in your March 16, 1990 submittal eie to be incorporated into the Rancho Seco Nuclear Generating Station USAR in the next required update.

^

A copy of the Safety Evaluation is also enclosed. The Notice of Issuance will be included in the Commission's biweekly. Federal Register notice.

Sincerely, S h k A. Teynolds, Project Manager Non-Power Reactor, Decommissioning and Environmental Project Directorate Division of Reactor Projects - III, IV, Y and Special Projects Office of Nuclear Reactor Regulation

Enclosures:

1.

Amendment No.115 to DPR-54 2.. Safety Evaluation ccw/ enclosures:

See next page DISTRIBUTION ts6u NRC &' Local PDRs PDNP r/f DCrutchfield WTravers Foster SReynolds

-OGC DHagan EJordan GHill(4)

WJones DNotley )

TDunning 0'O

JCalvo

^ ' * "

ACRS(10 GPA/PA SReynolds OC/LFMB Plant File (Gray)

GKalman

  • See previous concurrence lh Ih

.PDV:LA-PDV:DRSP PDV:PM SPLB

  • 0GC PDNP:D

-DFoster*

TBloxom SReyno ds:ta* CMcCracken* CBarth SWeiss 07/17/90 07/24/90-07/26/

07/27/90 08/17/90 09/7/90 g

9009140068 900910 gDR ADOCK0500gif2

h o w;

)

jf#**4 UMTED STATES

[

NUCLEAR RESULATCRY COMMISSION i

L-t 4

wAsmwoTow. o.c. rotu i

'.r I,[

.,,,,, + -

Septater 10, 1990 Docket No. 50-312 l

Hr. Dan R. Keuter

.)

Assistant General Hanecer. Nuclear-

_c Rancho Seco Nuclear Generating Station-i 14440 Twin Cities Poad j

' Herald, California. 95638-9799 i

Dear Hr. Keuter:

i

.l.

SUBJECT:

' ISSUANCE OF AMENDl!ENT NO.115TO FACILITY OPERATING LICENSE -

I NO.DPR-54,RANCHOSECONUCLEARGENERATINGSTATION(TACNO.75565)

'The Commission has issued the enclosed Amendment No.115 to Facility Operating License No. DPRiS4 for the Rcncho Seco Nuclear Generating Station.

This i

amenda nt consists'of changes to the license conditions, the Technical i

Specifications, and the Fire Protection Plan in response to your applicationL j

dated December 28, 1989, and supplemented March 16, 1990.

1

' The amenda nt revises the license concition concerning the Fire Protection 1

, Plan, adds administrative controls to the Technical Specifications (TS) in ~

support of the Fire Protection Plan and relocates the Fire Protection requirenwnts from the TS to the Fire Protection Plan as' described in Generic-1 Letters 86-10 and 88-12. '

I l

The proposed USAR char.ges included in your March 16, 1990, submittal are to_be l incorporated into the Rancho Seco Nuclear Generating Station USAR in the next

{

required update.

V+

A cony of the Safety Evaluation'is also enclosed. _The Notice of Issuance j

will be included in the Commission's biweekly rederal Register notice.

J Sincerely, m

h 1 Steven A. Reynolds, Project Manager 1

Non-Power Reactor, Decumissioning and Environinental Project Directorate Division of Reettor Projects - III, as IV, Y and Special Projects Office of Nuclear Reactor Regulation

Enclosures:

1.

Anendment 110. 115 to DPR-54 2.

. Safety Evaluation

+e f

cc w/ enclosures:

See next page

- g 1

,p 4

h'1

r a:

Mr. Dan R. Keuter Rancho Seco Nuclear Generating Station Cc:

Mr. S. David Freeman, General Manager Mr. John Bartus Sacramento Municipal Utility District Ms. JoAnne Scott 6201 S Street Federal Energy Regulatory Commission 3

P.O. Box 15830-825 North Capitol Street, N. E.

Sacramento, California 95852-1830 Washington, D.C.

20425 i

Thomas A. Baxter, Esq.

Ms. Helen Hubbard i

Shaw, Pittman, Potts & Trowbridge P. O. Box 63 2300 N Street, N.W.

Sunol, California 94586 Washington, D.C.

20037 Environmental Conservation Mr., Jerry Delezenski Organization Supervisor, Nuclear Licensing Suite 320 Rancho Seco Nuclear Generating Station 101 First Street 14440 Twin Cities Road Los Altos, California 94022 Herald, California 95638-9799 i

Ms. Jan Schori, General Counsel Mr. Robert B. Borsum, Licensing Sacramento Municipc1 Utility District Representative 6201 S' Street Babcock & Wilcox P.O. Box 15830 Nuclear Power Division Sacramento, California 95813 1700 Rockville Pike - Suite 525 Rockville, Maryland 20852

]

Resident Inspector / Rancho Seco c/o U. S. N. R. C.

14440 Twin Cities Road Herald, California 95638 Regional Administrator, Region V U.S. Nuclear Regulatory Commission 1450 Maria Lane, Suite 210 l

Walnut Creek, California 94596 Mr. John Hickman Senior Health Physicist Environmental Radioactive Management Unit Environmental Management Branch State Department of Health Services 714 P Street, Room 616 Sacramento, California 95814 Sacramento County Board of Supervisors 700 H Street, Suite 2450 Sacramento, California 95814 (12) e