WU lSMUD SACRAMENTO MUNICIPAL UTluTY DISTRICT O R O. Box 15830, Sacramento CA 95852 1830, (916) 452-3211 i
AN ELECTRIC SYSTEM SERVING THE HEART OF CALIFORNIA MPC&D 99-029 February 18,1999 j
Director, Division of Industrial and Medical Nuclear Safety Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission Washington, DC 20555 Docket No. 72-11 Rancho Seco Independent Spent Fuel Storage Installation RANCIIO SECO ISFSI SAR/RAI INCORPORATION MATRIX Attention: Randy Hall As requested in our mecting on February 9,1999, we are providing the attached matrix and two copies of the Rancho Seco Independent Spent Fuel Storage Installation (ISFSI) Safety Analysis Report (SAR), Revision 2 on compact disc. The attached matrix outlines where we incorporated our responses to the NRC's previous rounds of Requests for Additional Information (RAls)into Revision 2 of the ISFSI SAR. The first round of RAls dealt primarily with the use of the cask as a storage cask. Although we have requested that that the NRC no longer license the cask for storage, we have included the first-round questions in the matrix for completeness.
As you also requested, we are developing the following documents to facilitate completing your review of our 10 CFR 72 license application:
- 1. A matrix comparing our S AR with the current acceptance criteria in NUREG-1536
" Standard Review Plan for Dry Cask Storage Systems." The matrix will provide justification where our SAR deviates from NUREG-1536.
/
- 2. A revised version of our proposed technical specifications (SAR, Sections 10.3)in a 4-g format consistent with the Trojan ISFSI Technical Specifications.
F
- 3. Rancho Seco ISFSI SAR, Revision 3 which will remove any reference to the use of the MP-187 cask as a storage cask. We intend to store our loaded canisters in concrete horizontal storage modules (IISMs) only.
9903160050 990218
~'
PDR ADOCK 05000312 Y
PDR 2
RANCHO SECO NUCLEAR GENERATING STATIOW D 14440 Twin Cities Road, Herald CA 95638-9799; (209) 333-2935
)
R. Hall MPC&D 99-029 4
Our schedule for submitting these documents is:
Document Submittal Date NUREG-1536 matrix March 5,1999 Revised propo:ed technical specifications April 30,1999 Rancho Sew ISFSI SAR, Revision 3 May 30,1999 We look forward to discussing these items with you at our next meeting, scheduled for March 23, 1999, at your offices in Rockville, MD. Members of your staff with questions requiring additional information or clarification may contact Bob Jones at (916) 732-4843.
Sincerely, L
Steve Redeker 1
Manager, Plant Closure & Decommissioning cc:
E.W. Merschoff, NRC Region IV, Arlington i
Document Control Desk, Washington i
Rancho Seco ISFSI SAR Matrix Showina RAI Incorporation Question NRC issued Date SMUD Response Date SAR Sec. Cited Status Round 1 Sept.1,1994 February 28,1995 1
Vol. I, Sec.12 incorporated in Vol. I, Sec.12.3 2
Vol.1, Sec.12 incorporated in Vol. I, Sec.1.2.3 3
Vol 1, Sec. 2.2.3 incorporated in Vol. I, Sec. 2.2.3 4
Vol. I, Sec. 3.3.3.2 Incorporated in Vol. Ill, Sec.s 3.3.3 and 42.4 5
Vol. I, Sec. 3.3.5.2 Incorporated in Vol I, Sec. 3.3.52 Vol.1, Sec. 3.3.6 &
6 4.2.2.1(c)
Incorporated in Vol. I, Sec.10.3.9 7
Vol.1, Table 3-4 incorporated in Vol. I, Table 3-12 8
Vol I, Sec. 4.2.2.1(f)
Incorporated in Vol. I, Sec. 4.22.1(6) 9 Vol I, Sec. 42.2.1(l) incorporated in Vol. I, Sec. 422.1(12) 10 Vol I, Sec. 4.22.4(a)
Incorporated in Vol. I, Sec. 4.2.2.4(1) 11 Vol. I, Sec. 4.2.5.2.4(a)
Incorporated in Vol I, Sec. 4.2.5.3 12 Vol.111, Sec. 3.3.4 Incorporated in Vol 111. Sec. 3.3.4 13 Vol. Ill, Sec. 3.3.5 Incorporated in Vol.111. Sec. 3.3.5 14 Vol. Ill, Table 3-5 Incorporated in Vol. Ill, Table 3-6 15 Vol. Ill, Sec. 42.3.2 incorporated in Vol. Ill, Sec. 42.3.2 Vol. Ill, Sec. 4.2.4 &
16 DWG. NUH-05-4001 No SAR commitments 17 Vol Ill, Sec. 4.3 & 10.3 Incorporated in Vol I, Sec.10.3.10 Vol 111, Sec. 8.1.1.3.1 &
18 10.3.1(7)
No SAR commitments 19 Vol. lit, Sec. 8.1.4.2 No SAR commitments 20 Voi.111, Sec. 8.3.1.4 Incorporated in Vol. Ill, Sec. 8.3.1.4 21 Vol 111. Sec. 8.3 & 8.3.2 incorporated in Vol. Ill, Sec. 8.3.2.3(1) 22 Vol 111, Table 8-6 incorporated in Vol 111, Sec. 8.1.1.3.1 23 Vol. Ill, Sec.10.2.4 incorporated in Vol lil, Sec.102.4 24 Vol. Ill, Sec.10.3 Incorporated in Vol. ll1, Sec.10.3 25 Vol.111 Sec.10.3.2 incorporated in Vol lil, Sec.10.32 26 Vol 111, Sec.10.3.3 incorporated in Vol.111, Sec.10.3.3 27 Vol.111, Sec.10.3.3 Incorporated in Vol lil, Sec.10.3.3 28 Vol.111, Table 10-1 Incorporated in Vol.111. Table 10-1 29-40 Calculation changes only l
Page 1 of 4 L
Rancho Seco ISFSI SAR Matrix Showina RAI incorporation Question NRC issued Date SMUD Response Dates SAR Sec. Cited Status Round 2 March 14,1995 Apr. 6, May 9 & 24,1945 A
- General 1(1)
General Incorporated in Vol. I, Sec.10.3.10 General 1(2)
General No SAR commitments General 1(3)
General No SAR commitments General 2 General No SAR commitments General 3 General No SAR commitments General 4 General No SAR commitments General 5 General No SAR commitments General 6 General No SAR commitments General 7 General No SAR commitments General 8 General No SAR commitments 1-1 Vol.1, Table 3-3 No SAR commitments
!-2 Vol. I, Table 3-7 No SAR commitments 1-3 Vol. I, Table 3-5 No SAR commitments I-4 Vol. I, Sec. 4.2.5.2.3 No SAR commitments 1-5 Vol. I, Sec. 4.2.5.2.4 incorporated in Vol. I, Sec. 4.2.5.2.4 l-6 Vol. I, Sec. 42.52.4 See SAR App. A,"ASME Code Exception List" l-7 Vol. I, Chapter 9 incorporated in Vol. I, Sec.s 9 and 9.3.1.1 l-8 Vol. I, Sec.10.3.2 Incorporated in Vol. I, Sec.10.3.2 l-9 Vol. I, Sec. 10.3 & 32.3 incorporated in Vol. I, Sec.10.3.3 I-10 Vol. I, Sec. 7.42 Incorp.in Vol. I, Sec. 7.4.2 & Vol.11 Sec.10.3.3 1-11 Vol. I, Sec. 8.2.3.1 No SAR commitments i
1-12 Vol. I, Sec.10.2.5.1 No SAR commitments 1-13 Vol.1, Sec. 8.2.2 No SAR commitments 1-14 Vol. I, Sec. 8.2.2 No SAR commitments 1-15 Vol. I, Sec.10.3.7 incorporated in Vol. I, Sec.10.3.7 Vol. II, Sec.10.2.3 &
ll-1 10.3.3 incciporated in Vol. II, Sec.s 10.2.3 and 10.3.3 ll-2 Vol. li, Sec.10.3.1 Incorporated in Vol. II, Sec.10.3.1 11-3 Vol. II, Sec. 3.6 Incorporated in Vol. II, Sec. 3.6 11-4 Vol. II, Table 3-4 & 3-7 No SAR commitments 11-5 Vol. II, Sec. 8.1.1.2 No SAR commitments ll-6 Vol. II, Sec. 8.1.1.2 Incorporated in Vol. II, Sec. 8.1.1.2 ll-7 Vol. II, Table 7-1 Incorporated in Vol. II, Table 7-1 11-8 Vol. II, Sec. 7.3.2.2 No SAR commitments Page 2 of 4 e
r Rancho Seco ISFSI SAR Matrix Showina RAI Incorporation Question SAR Sec. Cited Status 11-9 Vol. II, Sec. 8.1.1.1 No SAR commitments 111-1 Vol. Ill. Sec.10.3.3 Incorporated in Vol. II, Sec.10.3.3 111-2 Vol. Ill, Table 8-1 No SAR commitments lil-3 Vol. lit, Table 10-1 Incorporated in Vol.111, Table 10-1 t
I i
Page 3 of 4 k -..
r Rancho Seco ISFSI SAR Matrix Showina RAI incornoration Question NRC lssued Date SMUD Response Date SAR Sec. Cited Status Round 3 Sept.12,1995 Nov.19,1998 0
General 6 General No SAR commitments General 8 General Incorporated in Vol.1, Sec.s 10.3.11 to 10.3.13 l-3 Vol. !, Table 3-5 No SAR commitments
.1 Calc 0500 Calc. 2069.0500 Incorporated in Vol. I, Table 7-2 Calc 0503
- Calc. 2069.0503 Incorporated in Vol. I, Sec. 7.4.1 Part 71 cask /DSC Drawings drawings Revised drawings submitted with SAR Vol. I, Sec. 3.3.3.2 & Vol.
41 111. Sec. 3.3.3 incorporated in Vol. Ill, Sec. 3.3.3 41(drawings)
N/A, pertains to cask storage 42 Vol. l. Sec. 4.2.2.1(f)
No SAR commitments Vol. Ill, Sec. 4.2.3.2 &
43 10.3.3 No SAR commitments 44 Vol.111, Sec.10.3.1 No SAR commitments 45 Vol.111, Sec. 8.1.1.1.1 A No SAR commitments 46 Calc. 2069.0401 No SAR commitments 47 Calc. 2069.0401 No SAR commitments 48 Vol. III Sec. 8.1.1.1.1 A Incorporated in Vol.111, Sec. 8.1.1.1.1(1) 49 Calc. 2069.0401 No SAR commitments Cales. 2069.0502 &
50 2069.0503 No SAR comrnitments 51 Vol. IV, Thermal Cales.
Thermal I/O files sent with RAI response Page 4 of 4 L