May 11, 1989
.. a Docket No.: 50-312 Mr. Joe Firlit Chief Executive Officer, Nuclear Rancho Seco Nuclear Generating Station 14440 Twin Cities Road Herald, California 95638-9799
SUBJECT:
REACTOR COOLANT PUMP TRIP FOR RANCHO SECO (TAC No. 49680)
Dear Mr. Firlit:
For the reactor ccolant pump (RCP) trip issue defined in the TMI Action plan item II.K.3.5 (Multiplant Action G-01), the staff generically approved the Babcock & Wilcox Owners Group (BWOG) methodology in Generic Letter 86-05, with the condition that plant-specific information needs to be addressed. Our review of the Rancho Seco plant-specific information has progressed to a degree that we can conclude that implementation of the BWOG methodology has signifi-cantly improved the reactor safety, and there are no major safety-significant concerns for the plant-specific information.
Accordingly, we have completed our review of your plant-specific RCP trip setpoint development and find it acceptable. This issue may be the subject of on-site verification.
Sincerely,
/s/
Steven A. Reynolds, Project Manager Project Directorate V Division of Reactor Projects - III, IV, V and Special Projects Office of Nuclear Reactor Regulation cc:
Sec attached list DISTRIBUTION eD6cket File jf SReynolds
'~NRC & LPDRs GKalman PD5 Reading OGC O
MVirgilio EJordan fg f
JLee BGrines ACRS (10)
DJaffe
- See previous concurrence DetSP/PDV*
DRSP/PDV*
DRSP/PDV DR' P'
JLee GKalman SReynol s G
h on 04/19/89 04/18/89 05/10/89 05/fj/89
$$f<*$$$0! $$$$h2 P
g recog'o UNITED STATES g
g NUCLEAR REGULATORY COMMISSION
,y.
G ij WASHINGTON, D. C. 20555 4
.(
t,s g
%*****/
May 11, 1989 Docket No.: 50-312 Mr. Joe Firlit Chief Executive Officer, Nuclear Rancho Seco Nuclear Generating Station 14440 Twin Cities Road Herald, California 95638-9799
SUBJECT:
REACTOR COOLANT PUMP TRIP FOR RANCHO SECO (TAC No. 49680)
Dear Mr. Firlit:
For the reactor coolant pump (RCP) trip issue defined in the TMI Action plan itemII.K.3.5(MultiplantActionG-01),thestaffgenericallyapprovedthe Babcock & Wilcox Cwners Group (BWOG) methodology in Generic Letter 86-05, with the condition that plant-specific information needs to be addressed. Our review of the. Rancho Seco plant-specific information has progressed to a degree that we can conclude that implementation of the BWOG methodology.has signifi-cantly improved the reactor safety, and there are no major safety-significant concerns for the plant-specific information.
Accordingly, we have completed our review of your plant-specific RCP trip setpoint development and find it acceptable. This issue may be the subject of on-site verification.
Sincerely, 1
Steven A. Reynolds, Project Manager Project Directorate V Division of Reactor Projects - III, IV, V and Special Projects Office of Nuclear Reactor Regulation cc: See attached list I
o
,,.s.
p Nr. Joe Firlit Rancho Seco Nuclear Generating
-l Station
{
.CC:
i Mr. David S. Kaplan, Secretary Mr. John Bartus and General Counsel Ms. JoAnne Scott Sacramento Municipal Utility District
. Federal Energy Regulatory Commission 6201 S Street 825 North Capitol Street, N. E.
P.O. Box'15830 Washington, D.C.
20425 Sacramento, California 95813 Thomas A. Baxter, Esq.
Ms. Helen Hubbard Shaw, Pittman, Potts & Trowbridge P. O. Box 63 2300 N Street, N.W.
Sunol, California 94586 Washington, D.C.
20037 Mr. Steven Crunk Manager, Nuclear Licensing Sacramento Municipal Utility District Rancho Seco Nuclear Generating Station 14440 Twin Cities Road Herald, California 95638-9799 Mr. Robert B. Borsum, Licensing Representative Babcock & Wilcox Nuclear Power Division 1700 Rockville Pike - Suite 525 Rockville, Marylano 20852 Resident Inspector / Rancho Seco c/o U. S. N. R. C.
14440 Twin Cities Road Herald, California 95638 Regional Administrator, Region V U.S. Nuclear Regulatory Commission 1450 Maria Lane, Suite 210 Walnut Creek, California 94596 Mr. Paul Szalinski, Chief Radiological Health Branch State Department of Health Services 714 P Street, Office Building #8 Sacramento, California 95814 Sacramento County Board of Supervisors 700 H Street, Suite 2450 Sacramento, California 95814 l