Line 46: |
Line 46: |
| ' ~c with reactor coolant pumps running had not been performed for Babcock & Wilcox plants. This lack of analysis, which is required by 10 CFR 50.46, is considered a defect under 21.3(d). The lack of analysis and absence of conclusions needed from such an analysis to ensure that current Babcock & Wilcox plants will be operated in a safe manner under normal and accident conditions, by itself, repre-sented a condition or circumstance and a defect as defined in 10 CFR 21.3(d). This lack of analysis was documented in internal Babcock & | | ' ~c with reactor coolant pumps running had not been performed for Babcock & Wilcox plants. This lack of analysis, which is required by 10 CFR 50.46, is considered a defect under 21.3(d). The lack of analysis and absence of conclusions needed from such an analysis to ensure that current Babcock & Wilcox plants will be operated in a safe manner under normal and accident conditions, by itself, repre-sented a condition or circumstance and a defect as defined in 10 CFR 21.3(d). This lack of analysis was documented in internal Babcock & |
| Wilcox memoranda, yet it was not identifed 'and considered in accord-ance'with procedures implementing the requirements of Part 21 for handling such a condition or circumstance to assure that a director or responsible officer was informed of such a defect. This item was subsequently evaluated under your Part 21 procedures during the summer of 1979. | | Wilcox memoranda, yet it was not identifed 'and considered in accord-ance'with procedures implementing the requirements of Part 21 for handling such a condition or circumstance to assure that a director or responsible officer was informed of such a defect. This item was subsequently evaluated under your Part 21 procedures during the summer of 1979. |
| Item 4. TVA transmitted a letter dated April 27, 1978, to Babcock & Wilcox (received May 3,1978) identifying a matter which represented a potential deviation or condition or circumstance concerning small break LOCAs at TVA's Bellefonte Nuclear Plant. This letter included a report by C. Michelson entitled, " Decay Heat Removal During a Very l; Small Break LOCA for a B&W 205-Fuel Assembly PWR." (Michelson Report). ' | | Item 4. TVA transmitted a {{letter dated|date=April 27, 1978|text=letter dated April 27, 1978}}, to Babcock & Wilcox (received May 3,1978) identifying a matter which represented a potential deviation or condition or circumstance concerning small break LOCAs at TVA's Bellefonte Nuclear Plant. This letter included a report by C. Michelson entitled, " Decay Heat Removal During a Very l; Small Break LOCA for a B&W 205-Fuel Assembly PWR." (Michelson Report). ' |
| t 0 | | t 0 |
| 9 | | 9 |
|
---|
Category:NOTICE OF VIOLATION OF A REGULATION
MONTHYEARML20207S2811987-03-17017 March 1987 Notice of Violation from Insp on 870126-30 ML20212F0181987-03-0202 March 1987 Notice of Violation from Insp on 870112-14 ML20211B8161987-02-13013 February 1987 Notice of Violation from Insp on 870112-14 ML20210G0091987-02-0202 February 1987 Notice of Violation from Insp on 861117-21 ML20213A0071987-01-29029 January 1987 Notice of Violation from Insp on 861119-21 ML20214Q1941986-11-18018 November 1986 Notice of Violation from Insp on 861020-24 ML20214A1871986-11-14014 November 1986 Potential Enforcement Finding from Insp on 860915-19 & 0929- 1003 ML20214A1161986-11-0707 November 1986 Notice of Violation from Insp on 860922-26 ML20211G9331986-10-30030 October 1986 Notice of Violation from Insp on 860908-10 ML20215N5631986-10-27027 October 1986 Notice of Violation from Insp on 860825-29 ML20211D8411986-10-20020 October 1986 Notice of Violation from Insp on 860915-18 ML20206U4421986-09-29029 September 1986 Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $40,000.Violation Noted:Mod Made to Main Hoist Brakes of Polar Crane W/O Engineering Change Memo or Work Permit for Added Hand Release Mechanism ML20210H0461986-09-24024 September 1986 Notice of Violation from Insp on 860623-27 ML20210C8971986-09-17017 September 1986 Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $50,000.Violation Noted:Incorrect Breaker Alignment Rendered Component Cooling Water Sys Loop B Inoperable for Approx 100 H ML20212P7341986-08-28028 August 1986 Notice of Violation from Insp on 860602-06 ML20214J8821986-08-12012 August 1986 Notice of Violation & Proposed Imposition of Civil Penalties on 850826-860515 ML20203H9311986-08-0101 August 1986 Notice of Violation from Insp on 860616-18 ML20203F0581986-07-28028 July 1986 Notice of Violation from Insp on 860414-30 ML20204B3451986-07-28028 July 1986 Notice of Violation from Insp on 860530-0604 ML20211P7261986-07-21021 July 1986 Notice of Violation from Insp on 860422-25 IR 05000701/20100151986-07-0303 July 1986 Notice of Violation & Proposed Imposition of Civil Penalties in Amount of $300,000,based on Violations Noted During 850701-1015 Insp Re Pull Rod Errors & Premature Criticality ML20206J2971986-06-25025 June 1986 Notice of Violation from Insp on 860512-16 ML20199F2961986-06-20020 June 1986 Notice of Violation from Insp on 860505-08 ML20195B7491986-05-27027 May 1986 Notice of Violation from Insp on 860304-05 ML20197E0081986-05-13013 May 1986 Notice of Violation from Insp on 860127-31 ML20197E5571986-05-13013 May 1986 Notice of Violation from Insp on 860317 & 18 ML20155G5591986-05-0202 May 1986 Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $50,000.Violation Noted:Attributes of Several Cable Tray Hangers Located in Reactor Bldg & Fuel Bldg Re Tray Size,Span & Clamps Incorrectly Determined ML20155G5531986-05-0202 May 1986 Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $200,000.Violation Noted:Qa Program Did Not Adequately Ensure That Qa/Qc Inspectors Appropriately Qualified ML20155G4111986-05-0202 May 1986 Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $120,000.Violation Noted:Qa Program Did Not Provide QC Inspector W/Sufficient Organizational Freedom to Identify Problems ML20203H9331986-04-28028 April 1986 Notice of Violation from Insp on 851209-13 ML20203A8511986-04-15015 April 1986 Notice of Violation from Insp on 851217 & 31 ML20210G2221986-03-31031 March 1986 Notice of Violation from Insp on 860210-14 ML20195B6901986-03-27027 March 1986 Notice of Violation from Insp on 860317-19 ML20154B3521986-02-28028 February 1986 Notice of Violation from Insp on 851104-08 ML20141G1451986-02-25025 February 1986 Notice of Violation from Insp on 860106-10 ML20153C0301986-02-14014 February 1986 Notice of Violation from Insp on 851209-13 ML20151T9661986-02-0707 February 1986 Notice of Violation from Insp on 850916-20 ML20140A7591986-01-21021 January 1986 Notice of Violation from Insp on 850916-19 ML20141H8151986-01-17017 January 1986 Notice of Violation from Insp on 850930-1004 ML20137B7481986-01-10010 January 1986 Notice of Violation from Insp on 850711-12 & 0805-09 ML20151N7071985-12-31031 December 1985 Notice of Violation from Insp on 851120 ML20136F5511985-12-27027 December 1985 Notice of Violation from Insp on 851015-17 ML20138Q4731985-12-24024 December 1985 Notice of Violation from Insp on 850812-16 ML20138L8301985-12-13013 December 1985 Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $900,000.Violations Noted:Failure of Listed Valves to Operate Properly on 850609 & Testing of Auxiliary Feedwater Pump Turbines Not Performed ML20137Y3041985-10-0303 October 1985 Notice of Violation from Insp on 850610-12 ML20134G9421985-08-26026 August 1985 Notice of Violation from Insp on 850528-31 ML20137H1791985-08-23023 August 1985 Notice of Violation from Insp on 850521-22 ML20134C0001985-08-13013 August 1985 Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $64,000.Violation Noted:Ge Ross Given Low Nov 1982 Interim & 1982-1983 Performance Ratings Due to Efforts to Bring Safety Concerns to Mgt Attention ML20133P1581985-08-12012 August 1985 Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $64,000.Violation Noted:Discrimination Against Bechtel Employee,Rd Parks,For Reporting Safety Problems Re Polar Crane Refurbishment ML20132C6351985-07-26026 July 1985 Notice of Violation from Insp on 850610-14 & 24-28 1987-03-02
[Table view]Some use of "" in your query was not closed by a matching "". Category:TEXT-INSPECTION & AUDIT & I&E CIRCULARS
MONTHYEARML20215G9881987-04-10010 April 1987 Notice of Nonconformance from Insp on 870223-27 & 0324 ML20206D8851987-04-0808 April 1987 Notice of Nonconformance from Insp on 870309-11 IR 05000354/19870101987-04-0707 April 1987 Insp Rept 50-354/87-10 on 870316-20.No Violations Noted. Major Areas inspected:post-accident Monitoring Sys Conformance W/Rev 2 to Reg Guide 1.97.Open Item Identified Re Identification of Category 2 Equipment ML20206M7981987-04-0707 April 1987 Insp Rept 50-312/86-41 on 861201-870212.Unresolved & Open Items Identified.Major Areas Inspected:Activities Supporting Restart & Ensuring Safe Operation of Plant After Restart, Including Stated Phases of Sys Review & Test Program ML20206D8361987-04-0707 April 1987 Insp Rept 99900271/87-01 on 870127-29.No Violations, Nonconformances or Unresolved Items Noted.Major Areas Inspected:Corrective Action Re Intermittent Failures & Review of Test Results on Three Failed Transmitters ML20215G9961987-04-0606 April 1987 Insp Rept 99900383/87-01 on 870223-27.Nonconformance Noted: Pressure Gauge Not Calibr for Over 0-30 Psig Range & 30 Psig Pressure Test of O-ring Seals Failed Pressure Drop Requirement ML20206F9681987-04-0303 April 1987 EN-87-029:on 870408,notice of Violation & Proposed Imposition of Civil Penalty in Amount of $50,000 Will Be Issued.Action Based on Loss of Approx 141,000 Gallons of Water from Spent Fuel Pools Through Fuel Transfer Canal IR 05000327/19870051987-04-0303 April 1987 Insp Repts 50-327/87-05 & 50-328/87-05 on 870119-23.No Violations or Deviations Noted.Major Areas Inspected:Review & Evaluation of 13 Employee Concern Task Group Final Sequoyah Element Repts IR 05000327/19870061987-04-0303 April 1987 Design Calculation Review Insp Repts 50-327/87-06 & 50-328/87-06 on 870202-13.No Violations Noted.Major Areas Reviewed:Adequacy of Util Design Calculation Review Program & Extent Program Augments Design Baseline Re Restart ML20206E8121987-04-0101 April 1987 Insp Repts 50-445/86-26 & 50-446/86-22 on 860901-1031. Violations & Deviations Noted:Cable Pulling Ropes Left in Unit 1 Conduits & Cable Trays & Failure of Inspector to Write Memo Documenting Nonconforming Condition IR 05000445/19860261987-04-0101 April 1987 Insp Repts 50-445/86-26 & 50-446/86-22 on 860901-1031. Violations & Deviations Noted:Cable Pulling Ropes Left in Unit 1 Conduits & Cable Trays & Failure of Inspector to Write Memo Documenting Nonconforming Condition ML20206D9141987-04-0101 April 1987 Insp Rept 99901085/87-01 on 870309-11.Nonconformances Noted: Failure to Administer Exam by Level III Examiner or Designated Representative & 1986 Eye Exams for Listed Level II Examiners Missing IR 05000327/19860681987-03-31031 March 1987 Insp Repts 50-327/86-68 & 50-328/86-68 on 861201-12 & 870112-23.Violations Noted:Licensee Failed to Assure That Applicable ASME Code Requirements Included in Procurement of Specific safety-related Code Class Equipment ML20215E4831987-03-31031 March 1987 EN-87-026:on 870331,order Suspending Power Operation & Order to Show Cause Issued to Util Due to Discovery That Control Room Staff Have Been Sleeping During Various Shifts.Related Documents Encl ML20206D1901987-03-31031 March 1987 Insp Rept 99901088/87-01 on 870121.Major Areas Inspected: Corrective Action Taken Re 860917 Part 21 Rept Concerning Potential Problem in Pressure Transducers ML20205R4601987-03-30030 March 1987 Insp Rept 99900762/87-01 on 870203-04.No Noncompliances or Violations Noted.Major Areas Inspected:Allegations Re Use of Uncertified Welders & Possible Falsification of Welding Records.Two of Nine Allegations Substantiated IR 05000267/19870041987-03-27027 March 1987 Insp Rept 50-267/87-04 on 870126-30.No Violations Noted. Major Areas Inspected:Program to Maintain Qualification of Electrical Equipment Per 10CFR50.49.Potential Enforcement/ Unresolved Items & Open Items of Program Listed IR 05000277/19870061987-03-23023 March 1987 Fitness for Duty Program Insp Repts 50-277/87-06 & 50-278/87-06 on 870202-06.Observations Noted:Util Written Policies Do Not Address Features of Commission Policy Statement or EEI Guide & No Overall Audit Performed ML20205H3661987-03-23023 March 1987 EN-87-023:on 870326,notice of Violation & Proposed Imposition of Civil Penalties in Amount of $50,000 Will Be Issued to Licensee.Action Based on Failure to Obtain Prior NRC Approval of Criteria Change for Reactor Coolant Flow ML20205H2411987-03-23023 March 1987 EN-87-022:on 870326,notice of Violation & Proposed Imposition of Civil Penalty in Amount of $12,500 Will Be Issued to Licensee.Action Based on Numerous Violations of NRC Requirements Re Overexposure to Workers ML20207S2811987-03-17017 March 1987 Notice of Violation from Insp on 870126-30 ML20207S2921987-03-17017 March 1987 Notice of Nonconformance from Insp on 870126-30 IR 05000275/19860331987-03-17017 March 1987 Insp Repts 50-275/86-33 & 50-323/86-31 on 861215-19. Deficiencies Noted.Major Areas Inspected:Implementation Program for Establishing & Maintaining Environ Qualification of Electrical Equipment Important to Safety ML20205D2131987-03-16016 March 1987 Insp Repts 50-445/86-22 & 50-446/86-20 on 860701-0831. Violations & Deviations Noted:Stainless Steel & Carbon Steel Stored in Outside Areas W/Improper Protective End Coverings & Records of Heat Treatment Not Available for Disc Inserts ML20207R5751987-03-13013 March 1987 EN-86-074A:on 870313,order Issued Imposing Civil Penalties in Amount of $3,000 to Univ of Utah,Based on Transportation, Health Physics,Safeguards & Operations Violations Noted in 860930 Enforcement Notification EN-86-074 ML20207R3341987-03-11011 March 1987 EN-87-019:on 870311,notice of Violation & Proposed Imposition of Civil Penalties in Amount of $50,000 Will Be Issued for Licenses.Action Based on Three Examples of Degraded Vital Area Barriers ML20207R4851987-03-0909 March 1987 EN-87-017:on 870312,notice of Violation & Proposed Imposition of Civil Penalty in Amount of $25,000 Will Be Issued to Util Based on Failure to Provide Adequate Design Control to Ensure Emergency Feedwater Pump Operability ML20207R3701987-03-0909 March 1987 EN-87-015:on 870312,notice of Violation & Proposed Imposition of Civil Penalties in Amount of $50,000 Will Be Issued for License.Action Based on Violation of Tech Spec Re ECCS Subsystems ML20207S3331987-03-0606 March 1987 Insp Rept 99901079/87-01 on 870126-30.Violation Noted:Two Nuclear Purchase Orders Accepted & Fulfilled W/O 10CFR21 Program in Effect.Nonconformance Noted:Master Ammeter Had No Sticker to Identify Calibr Status IR 05000327/19860701987-03-0303 March 1987 Insp Repts 50-327/86-70 & 50-328/86-70 on 861208-12.No Programmatic Deficiencies W/Regard to Facility Maint of Environmentally Qualified Equipment Identified.Major Areas Inspected:Maint Program & Previous Insp Items ML20207R0301987-03-0303 March 1987 EN-87-014:on 870306,notice of Violation & Proposed Imposition of Civil Penalty in Amount of $50,000 Issued to Licensee.Action Based on Failure to Establish & Maintain Operability of Nuclear Svc Water Sys ML20212F0181987-03-0202 March 1987 Notice of Violation from Insp on 870112-14 ML20212F0331987-02-27027 February 1987 Insp Rept 99901080/87-01 on 870112-14.Violation Noted: Failure to Adopt Procedure to Evaluate or Rept Defects Discovered in Motors Supplied to Customers Under Part 21 ML20212B1991987-02-26026 February 1987 EN-86-029A:on 870226,order Imposing Civil Monetary Penalty in Amount of $50,000 Issued to Licensee Based on Licensee 860703 Response to 860501 Notice of Violation & Proposed Imposition of Civil Penalty.Section I Violation Did Occur ML20212H0491987-02-26026 February 1987 EN-87-012:on 870303,notice of Violation & Proposed Imposition of Civil Penalty in Amount of $75,000 Will Be Issued Based on Violations in Areas of Facility Design,Maint & Mods IR 05000498/19860421987-02-20020 February 1987 Engineering Assurance Program Insp Repts 50-498/86-42 & 50-499/86-42 on 861215-19.Major Areas Inspected:Task 84-4, Separation & Fire Protection Criteria & Task 85-4, High Energy Line Break Analysis ML20211P4311987-02-19019 February 1987 EN-87-010:on 870224,notice of Violation & Proposed Imposition of Civil Penalty in Amount of $25,000 Will Be Issued to Util Based on Multiple Violations Re Safeguards Info Protection Program ML20212E7581987-02-18018 February 1987 Insp Rept 99900507/86-01 on 861201-05.No Violations or Noncompliance Noted.Major Areas Inspected:Status of Previous Findings,Dedication of Commercial Grade Items Overview & 10CFR21 Evaluation & Reporting Review ML20211B8481987-02-13013 February 1987 Notice of Nonconformance from Insp on 870112-14 ML20211B8161987-02-13013 February 1987 Notice of Violation from Insp on 870112-14 ML20211B9021987-02-13013 February 1987 Insp Rept 99900816/87-01 on 870112-14.Violation Noted:Mfg Did Not Specify Application of Part 21 Requirements on Listed Purchase Orders.Nonconformances Noted:Quality Sys Program Not Invoked on Listed Orders & Order Data Differed ML20211B5511987-02-12012 February 1987 EN-85-084A:on 851213,notice of Violation & Proposed Imposition of Civil Penalties in Amount of $900,000 Will Be Issued to Licensee.Action Based on 850609 Failure of Auxiliary Feedwater Sys to Perform Intended Function ML20210U0531987-02-10010 February 1987 Insp Rept 99901067/86-01 on 861103-07.Nonconformance Noted: NDE Technician Certified W/O Attaining Passing Grade on Magnetic Particle Exam,Per Procedure QC-2.Data Sheets Encl IR 05000321/19860351987-02-0707 February 1987 Equipment Qualification Insp Repts 50-321/86-35 & 50-366/86-35 on 861103-07.Major Areas Inspected:Program for Establishing & Maintaining Qualification of Electric Equipment Per 10CFR50.49.Five Deficiencies Noted ML20210E9371987-02-0606 February 1987 Insp Rept 99900015/86-01 on 861020-29.Noncomformance Noted: Mechanical & Chemical Testing Svc Performed by Outside Lab W/O Advising Lab of 10CFR21 Requirements & Incorrect Audits of Vendors ML20210E9201987-02-0606 February 1987 Notice of Nonconformance from Insp on 861020-24 IR 05000508/19860121987-02-0606 February 1987 Insp Rept 50-508/86-12 on 860915-1215.No Violations Noted. Major Areas Inspected:Readiness Review Program Module C3-01, Earthwork & Followup on Insp Repts 50-508/86-10 & 50-508/86-11 ML20210A9591987-02-0505 February 1987 Notice of Nonconformance from Insp on 861202-05 ML20210B0011987-02-0404 February 1987 Insp Rept 99900835/86-01 on 861203-05.Nonconformances Noted:Controls Necessary to Ensure Charging Motors Purchased from Subvendors Conform to Drawings Not Established ML20210P9041987-02-0303 February 1987 EN-87-005:on 870209,notice of Violation & Proposed Imposition of Civil Penalty in Amount of $50,000 Will Be Issued to Util Based on Ofc of Investigations Investigation Re Employment Termination of Technician 1987-04-08
[Table view]Some use of "" in your query was not closed by a matching "". |
Text
j
=
l APPENDIX A APR 101980 i
NOTICE OF NONCOMPLIANCE The Babcock & Wilcox Company Vendor No. 99900400 Based on the results of NRC investigations conducted on May 29 and November i 6-8, 1979, and review of the official transcripts of sworn testimony before j thi. President's Commission on the Accident at Three Mile Island, it appears ;
that certain of your activities were not conducted in full compliance with NRC l requirements as indicated below:
10 CFR 21.21(a) requires that "each individual, corporation, partnership or l other entity subject to the regulations in this part shall adopt appropriate '
procedures to (1) provide for (i) evaluating deviations or (ii) informing the licensee or purchaser of the deviation in order that the licensee or purchaser may cause the deviation to be evaluated unless the deviation has been corrected; and (2) assure that a director or responsible officer is informed if the con- )
struction or operation of a facility, or activity, or a basic component supplied 1 for such facility or activity: (i) Fails to comply with the Atomic Energy Act I of 1954, as amended, or any applicable rule, regulation, order or license of l the Commission relating to a substantial safety hazard, or (ii) Contains a .
defect..." ,
l 10 CFR 21.21(b) requires that each " director or responsible officer subject to the regulations of this part or a designated person shall notify the Commission when he obtains information reasonably indicating a failure to comply or a defect affecting (i) the construction or operation of a facility or an activity within the United States that is subject to the licensing '
l requirements under Parts 30, 40, 50, 70 or 71 and that is within his organiza- j tion's responsibility or (ii) a basic component that is within his organiza ' l tion's responsibility and is supplied for a facility or an activity within l the United States that is subject to the licensing requirements under Parts i l
30, 40, 50, 70 or 71."
B&W Administrative Procedures NPG 1707-01 (Processing of Safety Concerns) and -
No.1716-Al (Reporting of Defects and Noncompliance Concerning Safety) provide !
the Company's process for identifying, evaluating and initiating resolution of safety concerns relating to or affecting B&W supplied components, systems, or services, and to assure compliance with 10 CFR Part 21.
i Item 1. Contrary to the above, as early as November 1977, a B&W engineer wrote a memorandum concerning reactor operation procedures for certain small break LOCA conditions on Babcock & Wilcox reactors.
These concerns were about the sufficiency of guidance for operator {' '
actions to preclude interruption of high pressure safety injection, which could lead to possible uncovering of the core and fuel damage. t 4
8004280139
Appendix A APR 10 1980 Sufficient instructions are necessary to insure proper operator actions in response to a LOCA when the reactor is at full power to ensure safe operations. This absence of sufficient instruc-tions constitutes a defect as defined in 10 CFR 21.3(d). This insufficiency in operator instruction was' documented in internal
~
Babcock & Wilcox memoranda, but was not identified as a matter which should have been evaluated and considered in accordance with proce-dures implementing the requirements of Part 21 for handling such defects.
Item 2. Contrary to the above, senior engineers at Babcock & Wilcox were aware as early as November 1978, that analyses had not been performed for certain small break LOCAs using an auxiliary feedwater (AFW) level control of 10 feet for the Davis-Besse Nuclear Plant as required under 10 CFR 50.46. This lack of analysis represented a potential condition or circumstance that was documented in internal Babcock & Wilcox mcmoranda; yet it was not identified as a technical matter that should have been evaluated and considered in accordance with procedures implementing the requirements of Part 21 for handling such a potential condition or circumstance.
Item 3. Contrary to the above, senior engineers at Babcock & Wilcox were aware as early as November 1978, that a small break LOCA analysis
' ~c with reactor coolant pumps running had not been performed for Babcock & Wilcox plants. This lack of analysis, which is required by 10 CFR 50.46, is considered a defect under 21.3(d). The lack of analysis and absence of conclusions needed from such an analysis to ensure that current Babcock & Wilcox plants will be operated in a safe manner under normal and accident conditions, by itself, repre-sented a condition or circumstance and a defect as defined in 10 CFR 21.3(d). This lack of analysis was documented in internal Babcock &
Wilcox memoranda, yet it was not identifed 'and considered in accord-ance'with procedures implementing the requirements of Part 21 for handling such a condition or circumstance to assure that a director or responsible officer was informed of such a defect. This item was subsequently evaluated under your Part 21 procedures during the summer of 1979.
Item 4. TVA transmitted a letter dated April 27, 1978, to Babcock & Wilcox (received May 3,1978) identifying a matter which represented a potential deviation or condition or circumstance concerning small break LOCAs at TVA's Bellefonte Nuclear Plant. This letter included a report by C. Michelson entitled, " Decay Heat Removal During a Very l; Small Break LOCA for a B&W 205-Fuel Assembly PWR." (Michelson Report). '
t 0
9
, Appendix A APR 101980 This potential deviation or condition or circumstance was not con-sidered in accordance with procedures implementing the requirements of Part 21 for evaluating potential deviations or conditions or
' circumstances.
The foregoing facts constitute a violation in that they display:
a) a failure to evaluate and report; and b) a failure to establish adequate procedures to assure proper evaluation and reporting of significant safety information by responsible officials.
Each day of noncompliance with the regulations in 10 CFR 21.21 constitutes a ,
separate violation for which a civil penalty is imposed (December 4,1978 -
March 28, 1979, a total of 115 days). Cumulative Civil Penalty -
115 X $5,000 = $575,000.
The Atomic Energy Act of 1954, as amended, limits the total civil penalty to *
$25,000 within any 30-day period, thus limiting penalties for those items cited above to $25,000 for each 30-day period. Therefore a total penalty of
$100,000 is proposed.
This Notice of Noncompliance is sent to you pursuant to the provisions to Section 2.201 of the NRC's " Rules of Practice," Part 2. Title 10, Code of
, Federal Regulations. You are hereby required to submit to this office, within
_ twenty (20) days of your. receipt of this notice, a written statement or r explanation in reply, including for each item of noncompliance: (1) admission or denial of the alleged item of noncompliance; (2) the reasons for the item of noncompliance, if admitted; (3) the corrective steps which have been taken and the results achieved; (4) the corrective steps which will be taken to avoid further noncompliance; and (5) the date when full compliance will be achieved.
6 I
I e
-~ , - . -,