ML20137Y304

From kanterella
Jump to navigation Jump to search
Notice of Violation from Insp on 850610-12
ML20137Y304
Person / Time
Issue date: 10/03/1985
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE)
To:
Shared Package
ML20137Y301 List:
References
REF-QA-99901007 99901007-85-01, 99901007-85-1, NUDOCS 8510070288
Download: ML20137Y304 (1)


Text

.

APPENDIX A The Prescon Corporation Docket No. 99901007/85-01 NOTICE OF VIOLATION

~

As a result of the inspection conducted on June 10-12, 1985, and in accordance with Section 206 of the Energy Reorganization Act of 1974 and its implementing regulation 10 CFR Part 21, the following violation was identified and categorized in accordance with the NRC Enforcement Policy (10 CFR / art 2, Appendix C),

49 FR 8583 (March 8, 1984):

Section 21.21 of 10 CFR Part 21 states, in part:

"Each individual, corporation, partnership or other entity subject to the regulations in this part shall adopt appropriate procedures to:

(1) Provide for (i) evaluating deviations or (ii) informing the licensee or purchaser of the deviation in order that the licensee or purchaser may cause the deviation to be evaluated, unless the deviation has been corrected."

Contrary to the above, The Prescen Corporation did not develop a procedure to evaluate deviations or to inform the licensee or purchaser of the deviations.

This is a Severity Level V violation (Supplement VII).

l 4 P

010 9

-