ML20141H815

From kanterella
Jump to navigation Jump to search
Notice of Violation from Insp on 850930-1004
ML20141H815
Person / Time
Issue date: 01/17/1986
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE)
To:
Shared Package
ML20141E221 List:
References
REF-QA-99900054 NUDOCS 8604250040
Download: ML20141H815 (1)


See also: IR 05000930/2010004

Text

-_

- l

.

.

APPENDIX A I

Dresser Industries, Inc.

Docket No. 99900054/85-01

NOTICE OF VIOLATION

As a result of the inspection conducted on September 30-October 4, 19P5, and l

in accordance with Section'206 of the Energy Reorganization Act of 1974 and  ;

its implementing regulation 10 CFR Part 21, the following violation was '

identified and categorized in accordance with the NRC Enforcement Policy (10

CFR Part 2, Appendix C), 49 FR 8583 (March 8,1984): j

Section 21.21 of 10 CFR Part 21 states in part: "(a) Each individual, corpora-

tion, partnership... subject to the regulations in this part shall adopt appropriate

procedures to: (1) provide for: (i) evaulating deviations or (ii) informing

the licensee or purchaser of the deviation...(2)...of a facility, or activity,

or a basic component supplied...(i) relating to a substantial safety

hazard. .. (b)(1). ..a designated person shall noti fy the commission. . .(2). . .notifica-

tien shall be made to the Director, Office of Inspection and Enforcement, er to

the administrator of a regional office...(3) the written report shall include, l

but need not be limited to...(vi)...in the case of a basic component which I

'

contains a defect or fails to comply, the number and location of all such

components... supplied for one or more facilities...."

'

Contrary to the above, Dresser's Part 21 file no. 84-01 was not adequately

evaluated. File no. 84-01 identified a problem with disc collar failure for

3707RA safety valves. The file stated this problem was not reportable since

"The failure is an isolated case." However, a letter, dated 07/02/84, in the

same file states this failure has occurred twice since 1971. Once in August

1981 at Toledo Edison / Davis-Besse and the second time at Diablo Canyon Unit #2

in May 1984

Infornation in file no. 84-01 also indicates that in May,1984, during blowdown

testing by Wyle Laboratories, Huntsville, Alabama, on the main stean safety

valves from Pacific Gas & Electric /Diablo Canyon 2 (Dresser valve type 3707PA),

valve S/N BN1741 lifted with simultaneous shearing of the disc collar / spindle

threads and cotter pin. This occurred during the first actuation, at

approximately 1065 psig. The disc and soindle deflected sidewise upon

closing and the disc became wedged between the nozzle seat area at G the bottom

of the disc holder. The valve became mechanically jammed and could not open.

It also leaked severely because the disc was not seated properly.

As a result of this inadeouate Part 21 evaluation, Dresser has failed to

notify the NRC or its customers of this reportable Part 21 item (85-01-01).

This is a Severity Level !!! viglation (Supplement VIII.

s

.

l

l

8604250040 860411

PDR OA999 EMVDRSI

99900054 PDR i