t APPENDIX A Rockwell International Flow Control Division Occket No. 99901069/86-01' NOTICE OF VIOLATION As a result of the inspection conducted on October 20-24, 1986 and in accordance with Section 206 of the Energy Raorganization Act of 1974 and its implementing regulation 10 CFR Part 21, the following violation was identified and categorized in accordance with the NRC Enforcement Policy (10 CFR Part 2, Appendix C),
49 FR 8583 (Parch 8, 1984):
Section 21.31 of 10 CFR Part 21 dated May 31, 1984 states, in part, "Each...
corporation... subject to the regulations in this part shall assure that each procurement document for a... basic compone.it... specifies,s when applicable, that the provisions of 10 CFR Part 21 apply."
Contrary to the above, a review of documentation packages for Section III nuclear valves revealed that while 10 CFR Part 21 was imposed on Rockwell International (RI) by their customers, RI did not specify that 10 CFR Part 21 requirements i
would apply on Purchase Orders (P0) L6612 to Sherwin, M6635 to RI-Tulsa, L1119 and P1539 to Weldstar, and L24482 to Hylevel Screw Products.
(86-01-01) i
~
0612050028 861110 PDR GA999 EMVROCI PDR 99901069
.