APPENDIX A Anchor Darling Vald company Docket No. 99900053/86-01 NOTICE OF VIOLATION s
As a result of the inspection conducted on January 6-10, 1986 and in accordance with Section 206 of the Energy Reorganization Act of 1974 and its implementing regulation 10 CFR Part 21, the following violation was identified and categorized in accordance with the NRC Fnforcement Policy (10 CFR Part 2, Appendix C),
49 FR 8583 (March 8, 1934).
Section 21.31 of 10 CFR Part 21 dated May 31, 1984 states, in part, "Each...
corporation... subject to the regulations in this part shall assure that each procurement document for a... basic component... specifies, when applicable, that the provisions of 10 CFR Part 21 apply."
Contrary to the above, a review of documentation packages for Section III nuclear valves revealed that while 10 CFR Part 21 was imposed on Anchor Darling (AD) by their customers, AD referenced Section III requirements but did not specify that 10 CFR Part 21 requirements would apply on P0s C-432, C-433, A-1770, and A-1778 to Cann & Saul Steel; Y-2303 to Sandvik; Y-2489 and C-970 to Teledyne McKay; C-2348 to General Copper & Brass; A-3015 to R.E.C.; A-1496 to Dodge Foundry & Machine; and A-664 to Precision Technology.(86-01-01)
This is a Severity Level V violation (Supplement VII).