TABLE 4
TABLE 4
                                                                                                   .L  4. /,
                                                                                                   .L  4. /,
INDICATED STEAM GENERATOR-LEVEL(%) vs. ACTUAL LEVEL(%) AT 800 psi a INDICATED                            ACTUAL S/G LEVEL(%) AT TEMPERATURE LEVEL(%)                  125    150      175    200        225    250  275    300    325          350 75.00                  54.80    53.89    52.82    51. 61  50.28    48.84 47.29 45.64  43.88      42.00 80.00                  59.80    58.89    57.82  56.61    55.28    53.84 52.29 so*. 64 48.88      47.00
INDICATED STEAM GENERATOR-LEVEL(%) vs. ACTUAL LEVEL(%) AT 800 psi a INDICATED                            ACTUAL S/G LEVEL(%) AT TEMPERATURE LEVEL(%)                  125    150      175    200        225    250  275    300    325          350 75.00                  54.80    53.89    52.82    51. 61  50.28    48.84 47.29 45.64  43.88      42.00 80.00                  59.80    58.89    57.82  56.61    55.28    53.84 52.29 so*. 64 48.88      47.00 85.00                  64.80    63.89    62.82  61. 61    60.28  58.84 57.29 55.64  53.88      52.00 90.00                  69.80    68.89    67.82  66.61      65J28  63.84 62.29 60.64  58.88      57.00 95.00                  74.80    73.89    72.82  71. 61    70.28  68.84 67.29 65.64  63.88      62.00 100.00                79.80    78.89    77.88  76.61      75.28  73.84 72.29 70.64  68.88      67.00 C: ::o 1 ~""' TTn ; +- 1                                li.DD 1  Q                            °RPV -  11
;
85.00                  64.80    63.89    62.82  61. 61    60.28  58.84 57.29 55.64  53.88      52.00 90.00                  69.80    68.89    67.82  66.61      65J28  63.84 62.29 60.64  58.88      57.00 95.00                  74.80    73.89    72.82  71. 61    70.28  68.84 67.29 65.64  63.88      62.00 100.00                79.80    78.89    77.88  76.61      75.28  73.84 72.29 70.64  68.88      67.00 C: ::o 1 ~""' TTn ; +- 1                                li.DD 1  Q                            °RPV -  11


TABLE 5 INDICATED STEAM GENERATOR LEVEL(%) vs. ACTUAL LEVEL(%) AT 1000 psi a INDICATED                      ACTUAL S/G LEVEL(%) AT TEMPERATURE LEVEL(%)    125      150      175      200      225      250    275    300      325      350 0.00    -21. 23  -22.20    -23.35  '-24.63  -26.04  -27.56  -29.18 -30.92  -32.79    -34.79 5.00    -16.00  -16.97    -18.12  -19.40    -20.81  -22.33  -23.95 -25.69  -27.55    -29.55 10.00    -10.77  -11. 74  -12.88  -16.17    -15.58  -17.09  -18.72 -20.46  -22.32    -24.32 15.00    -  5.54  - 6.51  *-  7.65  - 8.94    -10.35  -11. 86  -13.49 -15.23  -17.09    -19.09 20.00    - 0.31  - 1. 28  - 2.42  -  3.71  - 5.11  -  6.63  - 8.26 -10.00  -11.86    -13.86 25.00      4.92    3.95        2.81    1. 52    0.12  -  1. 40 - 3.03 - 4.77  - 6.63    -  8.63 30.00    10.15    9.18        8.04    6.75      5.35    3.83    2.20  0.46  -  1. 40  -  3.40 35.00    15.38    14.41      13.27    11. 99  *10.58    '9.06    7.43  5.69    3.83      1. 83 40.00    20.62    1'9. 6 4    18.50    17.22    15.31    14.29  12.66  10.92    9.06      7.06 45.00    25.85    24.87      23.73    22.45    21. 04  19.52  17.90  16.16    14.29    12.29
TABLE 5 INDICATED STEAM GENERATOR LEVEL(%) vs. ACTUAL LEVEL(%) AT 1000 psi a INDICATED                      ACTUAL S/G LEVEL(%) AT TEMPERATURE LEVEL(%)    125      150      175      200      225      250    275    300      325      350 0.00    -21. 23  -22.20    -23.35  '-24.63  -26.04  -27.56  -29.18 -30.92  -32.79    -34.79 5.00    -16.00  -16.97    -18.12  -19.40    -20.81  -22.33  -23.95 -25.69  -27.55    -29.55 10.00    -10.77  -11. 74  -12.88  -16.17    -15.58  -17.09  -18.72 -20.46  -22.32    -24.32 15.00    -  5.54  - 6.51  *-  7.65  - 8.94    -10.35  -11. 86  -13.49 -15.23  -17.09    -19.09 20.00    - 0.31  - 1. 28  - 2.42  -  3.71  - 5.11  -  6.63  - 8.26 -10.00  -11.86    -13.86 25.00      4.92    3.95        2.81    1. 52    0.12  -  1. 40 - 3.03 - 4.77  - 6.63    -  8.63 30.00    10.15    9.18        8.04    6.75      5.35    3.83    2.20  0.46  -  1. 40  -  3.40 35.00    15.38    14.41      13.27    11. 99  *10.58    '9.06    7.43  5.69    3.83      1. 83 40.00    20.62    1'9. 6 4    18.50    17.22    15.31    14.29  12.66  10.92    9.06      7.06 45.00    25.85    24.87      23.73    22.45    21. 04  19.52  17.90  16.16    14.29    12.29
Line 295: Line 293:
TABLE 8 INDICATED PRESSURIZER LEVEL(%) vs. ACTUAL LEVEL(%) AT 1500 psi a INDICATED                  ACTUAL PRZ LEVEL(%) AT CONTAINMENT TEMPERATURE (Deg F)
TABLE 8 INDICATED PRESSURIZER LEVEL(%) vs. ACTUAL LEVEL(%) AT 1500 psi a INDICATED                  ACTUAL PRZ LEVEL(%) AT CONTAINMENT TEMPERATURE (Deg F)
LEVEL(%)    125      150        175      200      225      250    275    300    325    350 o.oo    -13.61  -14.73    -16.03  -17.48    -19.07  -20.79  -22.64  -24.61  -26.71  -28.95 5.00    -  9.67  -10.80    -12.09  -13.54    "'-15.13 -16.85  -18.70  720.68  -22.78  -25.01 10.00    -  5.74  -  6.36    -  8.16  -  9.61  -11.20  -12.92  -14.77  -16.74  -18.84  -21.08 15.00    - 1. 80  -  2.92    - 4.22  -  5.67  -  7.26  -  8.98 -10.83  -12.80  -14.91  -17.14 20.00        2.14    1. 01  -  0.28  - 1. 78  -  3.32  -  5.05 -  6.89 -  8.87 -10.97  -13.21 25.00        6.07    4.95      3.65    2.20      0.61  -  1.11 -  2.96 -  4.93 -  7.04 -  9.27 30.00      10.01    8.88      7.59    6.14      4.55    2.83    0.98 - 1. 00 -  3.10 - 5.33 c
LEVEL(%)    125      150        175      200      225      250    275    300    325    350 o.oo    -13.61  -14.73    -16.03  -17.48    -19.07  -20.79  -22.64  -24.61  -26.71  -28.95 5.00    -  9.67  -10.80    -12.09  -13.54    "'-15.13 -16.85  -18.70  720.68  -22.78  -25.01 10.00    -  5.74  -  6.36    -  8.16  -  9.61  -11.20  -12.92  -14.77  -16.74  -18.84  -21.08 15.00    - 1. 80  -  2.92    - 4.22  -  5.67  -  7.26  -  8.98 -10.83  -12.80  -14.91  -17.14 20.00        2.14    1. 01  -  0.28  - 1. 78  -  3.32  -  5.05 -  6.89 -  8.87 -10.97  -13.21 25.00        6.07    4.95      3.65    2.20      0.61  -  1.11 -  2.96 -  4.93 -  7.04 -  9.27 30.00      10.01    8.88      7.59    6.14      4.55    2.83    0.98 - 1. 00 -  3.10 - 5.33 c
35.00      13.94    12.82      11. 52  10.07      8.48    6.76    4.91    2.94    0.84 -  1. 40 40.00      17.88    16.75      15.46    14.01    12.42    10.70    8.85    6.87    4.77    2.54 45.00      21. 82  20.69      19.39    17.94    16.36    14.63  12.79  10.81    8.71    6.47
35.00      13.94    12.82      11. 52  10.07      8.48    6.76    4.91    2.94    0.84 -  1. 40 40.00      17.88    16.75      15.46    14.01    12.42    10.70    8.85    6.87    4.77    2.54 45.00      21. 82  20.69      19.39    17.94    16.36    14.63  12.79  10.81    8.71    6.47 50.00      25.75    24.63      23.33    21. 83    20.29    18.57  16.72  14.75  12.64  10.41 55.00      29.69    28.56      27.27    25.82    24.23    22.51  20.66  18.68  16.58  14.35 60.00      33.62    32.50      31. 20  29.:75    28.16    26.44  24.59  22.62  20.52  18.28 65.00      37.56    35.43      35.14    33.69    32.10    30.38  28.58  26.55  24.45  22.22*
' ;
50.00      25.75    24.63      23.33    21. 83    20.29    18.57  16.72  14.75  12.64  10.41 55.00      29.69    28.56      27.27    25.82    24.23    22.51  20.66  18.68  16.58  14.35 60.00      33.62    32.50      31. 20  29.:75    28.16    26.44  24.59  22.62  20.52  18.28 65.00      37.56    35.43      35.14    33.69    32.10    30.38  28.58  26.55  24.45  22.22*
70.00      41. 49  40.37      39.07'  37.62    36.03    34.31  32.46  30.49  28.39  26.15
70.00      41. 49  40.37      39.07'  37.62    36.03    34.31  32.46  30.49  28.39  26.15


Line 319: Line 315:
LEVEL(%)      125      150      175      200      225      250      275      300      325        350 0.00      -20.42  -21. 83  -23.50  -25.35    -27.35  -29.47  -31.76  -34.25    -37.02    -40.16 5.00      -15.42  -16.83    -18.50  -20.35    -22.34  -24.47  -  26.75 -29.24    -32.0l    -35.16 10.00      -10.41  -11. 82  -13.50  -15.35    -17.34  -19.47  -21. 75  -24.24    -7.7.01    -30.16 15.00      - 5.41  -  6.82  -  8.49  -10.35    -12.34  -14.47  -16.75  -19.7.4  -/.2.01    -25.15 20.00      -  0.41  -  1. 82  - 3.49  -  5.34  -  7.34 *- 9.46  -11. 75  -14.24    -17.01    -20.15 25.00        4.59    3.18      1. 51 -  0.34  -  2.34  -  4.46  -  6.74  -  9.23  -12.01    -15.15 30.00        9.59    8.19      6.51    4.66      2.67    0.54  -  1. 74 -  4.23  - 7.00    -10.15 35.00        14.60    13.19    11. 52    9.66      7.67    5.54    3.26    0.77  -  2.00    -  5.15 40.00        19.60    18.19    16.52    14.67    12.67    10.55    8.26    .5. 77    3.00    -  0.14 45.00        24.60    23.19    21. 52  19.67    17.67    15.55*  13.27    10.78      8.00        4.86 50.00        29.60    28.19    26.52    24.67    22.68    20.55    18.27    15.78    13.01        9. 86 55.00        34.61    33.20    31. 53  29.67    27.68    25.55    23.27    20.78    18.01      14.86 60.00        39.61    38.20    36.58    34.67    32.68    30.55    28.27    25.78    23.01      19.37 65.00        44.61    43.20    41. 53  39.68    37.68    35.56    33.27    30.78    28.01      24.87 70.00        49.61    48.20    46.52    44.68    42.69    40.56    38.28    35.79    33.02      29.37 Salem Unit 1                                  APP 1-20                                      Rev    11
LEVEL(%)      125      150      175      200      225      250      275      300      325        350 0.00      -20.42  -21. 83  -23.50  -25.35    -27.35  -29.47  -31.76  -34.25    -37.02    -40.16 5.00      -15.42  -16.83    -18.50  -20.35    -22.34  -24.47  -  26.75 -29.24    -32.0l    -35.16 10.00      -10.41  -11. 82  -13.50  -15.35    -17.34  -19.47  -21. 75  -24.24    -7.7.01    -30.16 15.00      - 5.41  -  6.82  -  8.49  -10.35    -12.34  -14.47  -16.75  -19.7.4  -/.2.01    -25.15 20.00      -  0.41  -  1. 82  - 3.49  -  5.34  -  7.34 *- 9.46  -11. 75  -14.24    -17.01    -20.15 25.00        4.59    3.18      1. 51 -  0.34  -  2.34  -  4.46  -  6.74  -  9.23  -12.01    -15.15 30.00        9.59    8.19      6.51    4.66      2.67    0.54  -  1. 74 -  4.23  - 7.00    -10.15 35.00        14.60    13.19    11. 52    9.66      7.67    5.54    3.26    0.77  -  2.00    -  5.15 40.00        19.60    18.19    16.52    14.67    12.67    10.55    8.26    .5. 77    3.00    -  0.14 45.00        24.60    23.19    21. 52  19.67    17.67    15.55*  13.27    10.78      8.00        4.86 50.00        29.60    28.19    26.52    24.67    22.68    20.55    18.27    15.78    13.01        9. 86 55.00        34.61    33.20    31. 53  29.67    27.68    25.55    23.27    20.78    18.01      14.86 60.00        39.61    38.20    36.58    34.67    32.68    30.55    28.27    25.78    23.01      19.37 65.00        44.61    43.20    41. 53  39.68    37.68    35.56    33.27    30.78    28.01      24.87 70.00        49.61    48.20    46.52    44.68    42.69    40.56    38.28    35.79    33.02      29.37 Salem Unit 1                                  APP 1-20                                      Rev    11


' ; *
TABLE 10 INDICATED PRESSURIZER LEVEL(%) vs. ACTUAL LEVEL(%) AT 2250 psi a INDICATED                ACTUAL PRZ LEVEL(%) AT CONTAINMENT TEMPERATURE (Deg F)
* TABLE 10 INDICATED PRESSURIZER LEVEL(%) vs. ACTUAL LEVEL(%) AT 2250 psi a INDICATED                ACTUAL PRZ LEVEL(%) AT CONTAINMENT TEMPERATURE (Deg F)
LEVEL(%)    125    150    175    200    225    250    275    300      325  350 75.00    54.62  53.21  51.53  49.68  47.69  45.56  43.28  40.79  38.02  34.87 80.00    59.62  58.21  56.54  54.68  52.69  50.56  48.28  45.79  43.02  39.88 85.00    64.62  63.21  61. 54  59.62  57.69  55.57  53.28  50.79  48.02  44.88 90.00    69.62  68.21  66.54  64.69  62.69  60.57  58.29  55.80  53.02  49.99 95.00    74.63  73.22  71. 54  69.69  67.70  .65.57  63.29  60.80  58.03  54.88 100.00    79.63  78.22  76.55  74.69  72.70  70.57  68.29  65.80  63.03  59.88
LEVEL(%)    125    150    175    200    225    250    275    300      325  350 75.00    54.62  53.21  51.53  49.68  47.69  45.56  43.28  40.79  38.02  34.87 80.00    59.62  58.21  56.54  54.68  52.69  50.56  48.28  45.79  43.02  39.88 85.00    64.62  63.21  61. 54  59.62  57.69  55.57  53.28  50.79  48.02  44.88 90.00    69.62  68.21  66.54  64.69  62.69  60.57  58.29  55.80  53.02  49.99 95.00    74.63  73.22  71. 54  69.69  67.70  .65.57  63.29  60.80  58.03  54.88 100.00    79.63  78.22  76.55  74.69  72.70  70.57  68.29  65.80  63.03  59.88


Line 336: Line 331:
LEVEL(%)    125      150    175        200      225    250    275  300      325    350 75.00    59.33    57.68  55.86  .53.84      51. 61 49.18  46.56 43.76  40.81  37.15 80.00    64.95    63.30  61. 48    59.* 46  57.23  54.80  52.18 49.38  46.43  43.37 85.00    70.57    68.92  67.10  . 65.08    62.85  60.42  57.80 55.00  52.05  48.99 I
LEVEL(%)    125      150    175        200      225    250    275  300      325    350 75.00    59.33    57.68  55.86  .53.84      51. 61 49.18  46.56 43.76  40.81  37.15 80.00    64.95    63.30  61. 48    59.* 46  57.23  54.80  52.18 49.38  46.43  43.37 85.00    70.57    68.92  67.10  . 65.08    62.85  60.42  57.80 55.00  52.05  48.99 I
   . j
   . j
     !  90.00    76.19    74.54  72.72    70.70    68.47  66. 0.4 63.42 60.62  57.67  54.61
     !  90.00    76.19    74.54  72.72    70.70    68.47  66. 0.4 63.42 60.62  57.67  54.61 95.00    81. 81  80.16  78.34. 76.32    74.09  71. 66  69.04 66.24  63.29  60.23 100.00    87.43    85~78  83.96    81. 94    79.71  77.28  74.66 71. 86  68.91  65.85
.. ";
95.00    81. 81  80.16  78.34. 76.32    74.09  71. 66  69.04 66.24  63.29  60.23 100.00    87.43    85~78  83.96    81. 94    79.71  77.28  74.66 71. 86  68.91  65.85


Appendix E Integrated Operating Procedures IOP-2, Cold Shutdown to Hot Standby IOP-3, Hot Standby to Minimum Load
Appendix E Integrated Operating Procedures IOP-2, Cold Shutdown to Hot Standby IOP-3, Hot Standby to Minimum Load
*}}
*}}

Latest revision as of 12:45, 23 February 2020

Rev 11 to Recovery from Safety Injection.
ML18087A741
Person / Time
Site: Salem  PSEG icon.png
Issue date: 03/13/1983
From: Connor B
Public Service Enterprise Group
To:
Shared Package
ML18087A720 List:
References
EI-I-4.2, NUDOCS 8303160598
Download: ML18087A741 (39)


Text

{{#Wiki_filter:\ SALEM GENERATING STATION

Title:

OPERATIONS DEPARTMENT DOCUMENT APPROVAL COVER SHEET-Recovery from Safety Injection No.:EI-I-4.2 1 11 Unit: Rev.: Remarks: 11 oaaes of text, 1 attachment, 1 table, 1 appendix. Chanqes: Added note and steps a,b,c and d to st.ep 4.12, changed steo 4.18, chanqed steos 4.27,4.28 and added steps 4.29,4.30,4.31. Safety Related Review (Ref. AD-13) : S/R yes x no Author's Checklist Comp~eted: yes x Author ~ ~~ Date °3/ 13J t3 I SR6'D ' --~'f!-. .a .

                                          ,.,..                 Date,~ -{3 ,&,S j~                                           Date :J-/3-ff3" L

Ops. Eng. I* sos+ ,.&IL &_,.,a dt,, .!VJ Date ,5/;..;/R? Ops. Mgr. Y/?J~- .. Date J-/J-~ QA ** Q_Q_:__Q~~ Date 3 /t3/&~ I ' SORC ** ~ Date

                                                                     /

Y//:J//'J. General Manager *'*

                                   ;iJ9\-#~,~                   Date   3/1-?/h
  • required for SPM documents only
    + required for EOP validation acceptance only
    *'*  required for safety related documents and fire protection document-s 8303160598 830314             'i PDR ADOCK 05000272             I S                  PDR Salem Unit 1/2                       AD-1-B-1       MASTER

-(. EMERGENCY INSTRUCTION I-4.2 RECOVERY FROM SAFETY INJECTION

1. 0 PURPOSE 1.1 To delineate the steps required to term.l.nate Safety Injection and return the unit to a normal, shutdown alignment.

2.0 INITIAL CONDITIONS 2.1 The conditions as described in one of the following Emergency Instruction exist such that termination of Safety Injection is required or desirable. 2.1.1 EI I-4.0, "Safety Injec~ion Initiation" 2.1.2 EI I-4.4, "Loss of Coolant" 2.1.3 EI I-4.6, "Loss of Secondary Coolant" 2.1.4 EI I-4.7, "Stearn Generator Tube Rupture" 3*. 0 IMMEDIATE ACTIONS 3.1 None 4.0 SUBSEQUENT ACTIONS COMMENTS 4.1 The Senior Shift Supervisor/ Once Safety Shift Supervisor shall verify Injection is that the initial conditions reset it will not described in Step 2.1 above automatically are.satisfied. The Operator reinitiate until shall then proceed as follows: after the Reactor Trip Breakers have been reset. 4.1.1 When RCS pressure is greater than 2000 open 1CV139, 1CV140 CAUTION In order to prevent excessive loss of water to the eves Holdup Tanks do not operate with 1CV139, 140 open for a period longer than 15 minutes.

  • Salem Unit' 1 1 Rev. 11

I-4.2

  • 4.1.2 Refer to Table I. If any of the criteria listed under the column "Safety Injection Reinitiation Criteria" for the appropriate accident exist at any time after Safety Injection is reset, manually reinitiate Safety Injection.

4.1.3 Maintain Safety Injection in operation until the criteria listed in Table I under the column "Actions Required After Reinitiation" for the appropriate accident are satisfied. 4.2 Control Auxiliary Feedwater flow to Refer to Appendix maintain an actual level of 1 to determine approximately 33% in the Narrow indicated level Range in all unaffected Stearn which will assure Generators. approximately 33% actual level .

  • 4.2.1 If Auxiliary Feedwater flow has been interrupted to any Steam Generator for more than 5 minutes and the level has coincidentally been less than 10% in the This applies-throughout the recovery.

Narrow Range for more than 5 minutes, flow must be maintained less than lOxlO 4 LBM/HR. until the level is greater than 10%. 4.3 If the Safety Injection was due to Circuits may a break inside the Containment, be re-energized de-energize the following circuits: at the direc.tion of the Shift Supervisor to perform specific evolutions after Safety Injection is reset .

  • Salem Unit 1 2 Rev. 11

I--4. 2

  • 4.3.l l~-~DC Ckt 9 - 1CV4 Ckt 11 - 1SJ123 Ckt 11 also de-energizes 1NT32, and 11&12SJ50 4.3.2 lBBDC Ckt 19 - 1CV3 Also de-energizes 1CV7, J C'.72 ,. and 1CV277 4.3.3 lCCDC Ckt 13 - 1WL98 Ckt 13 Also de-energizes lWL 7, 1WL12, 1WL16, and 1WL96 Ckt 15 - 1CV5 Ckt 15 Also de-energiz*es 1CV131, 1CV132, 1CV134, and 1CV278.

4.4 If the Safety Injection was due Circuits may be to a break in the Inboard re-energized at Pen~tration Area, de-en~rgize the direction of the following circuits: the Shift Supervisor to perform specific evolutions after Safety Injection is reset. 4.4.1 lAADC Ckt 7 -* 1CC113, and 1CC215 Ckt 33 - 11CA330 4.4.2 lBBDC Ckt 1 - 12CA330 Ckt 1 also de-energizes 1RC41, and 1RC42 Ckt 17 - 1SJ60 Ckt 17 also de-energizes 12SJ20, 12SJ27, 12SJ57,12SJ58, and 12SJ93 Ckt 19 - 1CV7 Ckt 19 also de-energizes 1CV2, 1CV3, and 1CV277 I Ckt 26 - 1SJ27,1SJ33, 1SJ49, 1SJ64, and 11-14SJ94

  • Salem Unit 1 3 Rev. 11

I-4.2

  • Ckt 34 - 1WL13,1WL17, 1WL97, 1WL99~ and 1WL108 Ckt 34 also de-energizes 11-14WG29,ll-14 WG42,1WG41,and 1WL51 4.4.3 lCCDC Ckt 33 - ll-14GB4 4.4.4 ;DDDC Ckt 28 - 1SJ53 Also de-energizes 1SJ158,1SJ159, 1SJ166, and 11&12SJ162 4.5 Reset the following signals: It is not necessary at this time to reset Containment Ventilation or Feed water Isolation.

4.5.1 Depress the Train "A" and Tr~in "B" SI RESET pushbutton; on the control console to reset the

  • 4.5.2 Safety Injection signal~

bepress the Train "A" and Train "B" c*oNT ISOL PHASE A RESET pushbuttons on the Control Console, tQ The status lights associated with Phase A on RP-4 should go out.. reset the Containment Phase A Isolation signal. 4.5.3 Depress the EMERGENCY LOADING The status lights RESET pushbuttons, on the on RP-4 Control Console, for lA, lB associated with lC Diesel Generators to the SEC loading reset the Safeguards loading *should go out. sequence.

a. If any safeguards loading sequence train fails to reset, perform the following for the affected train:
1. At panel lRPl rotate the Train A&B lA, lB or lC SEC BLOCK SWITCH to the SEC Block position .
  • Salem Unit 1 4 Rev. 11

I-4.2

  • 2. On the Auxiliary Annunciator
                           .System observ~ the following alarm: SI INPQT TRAIN A&B
                            *lA, lB or lC SE(S:_ BLOCK
                                                \
3. 'Go to step 4. 5. 3 \nd DEPRESS
                            .the EMERGENCY LOA!:'ING P..ESET pushbutton, then proceed to step 4.5.4.

4~5.4 Depress the 230V CONTROL The 230V Control CENTER RESET on the Control Centers may Console for lA, lB and lC already be reset Diesel. Generator. if the 20 minute timer has timed out. 4.6 Restore power to and open the Ckt No. Containment Control Air Header lAADC Ckt 33 - lA, and lB Isolation Valves. 11CA330 lBBDC Ckt 1 - 12CA33.0 11CA330 12CA33 0

  • 4.7 If possible, restore power to the following circuits:

lAADC Ckt 9, lBBDC Ckt 19 lCCDC Ckt 15, then, Return the Charging Pumps to their Insure No. 13 normal iineup IAW OP II~3.3.2, Charging Pump is "Operating the Charging Pumps", in service before and re-establish charging and stopping No. 11 & letdown flow IAW OP II-3.3.1, 12 Charging "Establishing Charging, Letdown Pumps. and Seal Injection Flow". 4.7.1 Control actual pressurizer Refer to Appendix level at approximately 22% 1 to determine indicated level which assures approximately 22% actual level.

  • Salem Unit 1 5 Rev. 11

I-4.2

  • 4.8 If the Reactor Coolant Pumps are not runninq, start at least one pump IAW OP II-1.3.1, "RCP Operation", in an unaffected loop.

It is preferred to start No. 13 RCP since this loop has both pressurizer surge and spray. If No. 13 is not available, start No. 11. 4.9 If normal charging and Letdown Insure a were established in step 4.7 then, di"scharge flow open the Centrifugal Charging path. Pump Mini-Flo Valves, 1CV139 & 140 if closed then stop the flow thru the Boron Injection Tank by closing Inlet Valves 1SJ4 and 1SJ5. Stop the Centrifugal Charging Pumps which are not being used for normal charging. 4.10 If normal charging & letdown cannot be established, maintain pressurizer level greater than 20% by periodically cycling 1SJ4 or 5 and 1SJ12 or 13.

     - 4.11 STOP the RHR Pumps and Safety        The pumps are Inje*ction Pumps                     running on Recirc.

4.12 Return the Service Water System to Normal Lineup IAW OP V-1.3.1, "Service Water - Normal Operation" 4.12.1 Reestablish Service To prevent Water to the Turbine shocking the Building S.W. Piping and Coolers in

a. OPEN 11SW20 the Turbine.

Partially open

b. OPEN 13SW20 1SW26 manually at s.w.
c. OPEN 1SW26 structure to Pressurize
d. START or STOP system.. THEN Service Water open completely Pumps to return by motor service water operation from
                       *pressure to Normal . control console.
  • Salem Unit 1 6 Rev. 11

I-4.2

  • 4.13 Return Diesel Generators lA, lB and lC to normal operation IAW OP IV-16. 3. 1, "Emergency Power - Diesel Operation" 4.14 Return the Containment Ventilation System to normal operation IAW OP II-16.3.1, "Containment Ventilation Operation".

4.15 Return the Auxiliary Building

          ,Ventilation System to normal operation IAW OP II-17.3.1, "Auxiliary Building Ventilation Operation."

4.16 Return th~ Control Room Ventilation System to normal operation IAW OP II-17.3.2, "Control Room Ventilation Operation." 4.17 Verify the Emergency Control Air Compressor stops when Control Air pressure is normal and return the Control Air System to normal operation IAW.OP V-5.3.1, "Control Air System Operation." 4.18 MAINTAIN Stearn Generator levels in accordance with OP III-10.3.1, "Auxiliary Feedwater System Operation." 4.18.1 Refill the Auxiliary The Condensate Feedwater Storage Tank Pumps may be as necessary. stopped if desired 4.19 Restore power to 11-14GB4 if lCCDC Ckt 33 possible and return the Stearn Generator Drains and Blowdown System to normal operation IAW OP III-13.3.2, "Stea.rn Generator Blowdown - Normal Operation". 4.20 Return the Containment/Plant Vent Radiation Monitor to normal operation IAW OP IV-11.3.3, "Process Radiation Mqnitors Normal Operation .

  • Salem Unit 1 7 Rev. 11

I-4.2

  • 4.21 Restore power to 1WL96 and 1WL97 if possible and return the Inlet Valves to the Gas Analyzer, from the Reactor Coolant Drain Tank and Pressurizer Relief Tank, to normal by opening the following valves:

1WL96 - lCCDC Ckt13 1WL97 - lBBDC Ckt34 1WL96 1WL97 1PR18 1PR17 4.22 Drain and refill Boron Injection DO NOT remove the Tank from the Boric Acid Tanks power from 1SJ4, IAW OP II-4.3.5, "Flushing and 5, 12, 13 as this Draining the Boron Injection Tank" will make the Boron Injection Tank inoperable. CAUTION DO NOT isolate the Boron Injection Tank during the refilling process or during the subsequent sampling to insure the flow path thru the BIT is operable.

  • NOTE The BIT Boron Concentration is below the Tech Spec limit.

4.23 Return the Safety Injection System to normal IAW OP II-4.3.1, RWST and BAT levels may be low "Safety Injection System - Normal Operation."

      -4.24 Make a visual inspection within the Containment when entry is permissible.

4.25 After the plant has stabilized, sample the Reactor Coolant System for boron concentration and H2. Adjust boron as necessary IAW OP II-3.3.6, "Boron Concentration tontrol" for the desired plant conditions. Degas the RCS as necessary IAW OP II-3.3.11, "Volume Control Tank Degassification". 4.26 Calculate the Shutdown .,Margin IAW the Reactor Engineer's Manual to ensure that the Reactor is shutdown by greater than 1.6% Delta k/k .

  • Salem Unit 1 8 Rev. 11

I-4.2

  • 4.27 Perform the following reviews of the Reactor Trip/Safety Injection:

4.27.1 INITIATE AD-16, "Post Reactor Trip/ Safety Injection Review and Unit Startup Approval Requirements." 4.27.2 Complete Attachment No. 1 "Post Safety Injection Data" and attach it to AD-16, "Post Reactor Trip/Safety Injection Review." 4.27.3 INITIATE an Operational Incident Report in accordance with AP-6, "Incident Report and Reportable Occurrence Program." 4.28 If, at this time, it becomes

  • neces.sary, take the plant to the Cold Shutdown condition IAW IOP-6, "Hot Standby to Cold Shutdown."

NOTE Do not continue until requirements of AD-16 "Post Reactor Trip/Safety Injection Review" are completed and approved. 4.29 Upon completion of AD-16 "Reactor Trip/Safety Injection Review" Sect. 4. 0 , "Approval Requirements for Reactor Startup" withdraw the Shutdown Banks as follows: 4.29.l Reset the flux rate t+ip Any reactor by momentarily taking trip from power the RATE MODE switches, will generate a on each NIS POWER RANGE negative rate A drawer, to the RESET trip signal position. which seals in and must be manually reset .

  • Salem Unit 1 9 Rev. 11

I-4.2

  • 4.29.2 Depress the CLOSE pushbutton on the control console, for REACTOR TRIP BKR A, verifying the breaker does close.

4.29.3 Depress the CLOSE pushbutton on the control console for REACTOR TRIP BKR B, verifying the breaker does close.

                            \

4.~9~4 Depress the STARTUP If the STARTUP pushbutton, on the Control pushbutton has Console, and verify each been pushed prior Shutdown and Control Rod to closing the Step Counters reset to Reactor Trip zero. Beakers, a Rod Urgent Failure Alarm will be present. This can be

  • cleared by pu~hi'ng either the STARTUP pushbutton or the ALARM RESET pushbutton.
  • 4.29.5 Commence withdrawing Shutdown Bank A,B, C and D, in that order, to their fully withdrawn position .
  • Salem Unit 1 10 Rev. 11

I-4.2

  • 4.30 With Stearn Generator levels within their normal operating bands and just prior to commencing startup, perform the following:
  • 4.30.1 Place the Stearn
                   . Generator Feedwater Controls in MANUAL and run the valve demand to zero.

4.30.2 Reset the Feedwater Isolation signal by depressing the Train "A" and Train "B" FEEDWATER ISOLATION RESET pushbuttons on the control console. 4.31 Return to Power.Operation IAW IOP_<:'.'3, "Hbt Standby to Minimum Load", and IOP-4, "Power Operation." END OF PROCEDURE

                                  - FINAL PAGE
  • Salem Unit 1 11 Rev. 11

\ I-4.2

  • \\

ATTACHMENT NO. 1 POST SAFETY INJECTION DATA

 \

Initial Pressurizer Level  % Final Pressurizer Level  % Initial Pressurizer Pressure PSIG Final Pressurizer Pressure PSIG Initia1 Tavg op Final Tavg op RWST Temperature (T0650A)

  • op Duration of Safety Injection Min.
  • Reviewed by Senior Shift Supervisor/Shift Supervisor DATE DATE
                                                                   ~~----
  • Salem Unit 1 ATT 1 ... 1 Rev. 11
                         .  ' ... ~*. *' *. , .
  • ~*

TABLE I SAFETY INJECTION SAFETY INJECTION ACTIONS RF.QUIRED SAFETY INJECT ACTUATION TERM CRITERIA(l) REINITIATION CRITERIA(2)* AFTER REINITIATION(l)

1. Spurious SI EI-4.0 1. RCS PRESS l.RCS LESS THAN 1765PSIG I.Return to EI 4.0 greater than and re-evaluate 2000 PSIG
2. PRZ level 2. PRZ level LESS T~AN 2.Increase subcoolinq greater than 22% 10% to 65°F or Increase RCS Press.

to 2200 PSIG

3. Subcooling 3. Supcooling LESS THAN greater than 50PF 50°F
4. AFW greater than 42xE4 lb/Hr or S/G level greater than 5%

Narrow Range(lS/G)

2. Small LOCA 1.RCS PRESS I.RCS LESS THAN 1765PSIG 1. Return to EI-4.0 EI 4.4 greater than and re-evaluate 2000 PSIG 2.PRZ level 2.PRZ level LESS THAN 2.Increase subcooling greater than 20% to 65°F 50% or 3.Subcooling 3.Subcooling LESS THAN greater than 50°F 50°F 4.AFW greater Increase RCS Press than 42xE4 lb/hr. to 2200 PSIG or S/G level greater .than 5%

Narrow Ranqe(lS/G)

TABLE I SAFETY INJECTION SAFETY INJECTION ACTIONS REQUIRED SAFETY INJECT ACTUATION TERM CRITERIA(I) REINITIATION CRITERIA(2) AFTER REINITIATION(I) I. Loss of Secondary I. RCS Press l.RCS Press drops by I.Return to EI-4.0 Coolant - one TH greater than 200PSIG and re-evaluate LESS THAN 350°F 700 PSIG . EI-4.6 2.PRZ Lvl greater 2.PRZ Lvl drops by IO% 2.Increase subcooling than 20% to 65°F by cooldown 3.Subcooling 3.Subcooling LESS THAN 3.Return RCS Press to greater than 50°F 50°F the value at termination 4.AFW greater than 42xE4 LB/HR or S/G Lvl greater than 5% Narrow Range(IS/G)

4. Loss of Secondary 1. RCS Press I.RCS Press drops by 1.Return to EI 4.0 Coolant -All TH greater than* 200 PSIG and re-evaluate greater than 350°F 2000PSIG 2.PRZ Lvl drops by 10% 2.Increase subcooling EI 4.6 2.PRZ Lvl to 65°F bv cooldown greater than 20% 3.Subcooling LESS THAN 3.Return RCS Press to 3.Subcooling 50°F the value at greater than termination 50°F 4.AFW greater than 42xE4 LB/HR or S/G LVL greater than 5% Narrow Range (IS/G)

(1) ALL CRITERIA MUST BE MET (2) ANY OF THE CONDITIONS REQUIRE RE.INITATION

I-4.2 APPENDIX 1 DETERMINATION OF ACTUAL PRESSURIZER AND STEAM GENERATOR LEVELS To determine actual Pressurizer or Steam Generator Levels, utilize the attached Tables as described below. Tables 1-5 are to be used for the Steam Generators Tables 6-11 are to be used for the Pressurizer

1. Obtain the Average Containment Temperature from Computer Point Ul304.
2. Refer to the appropriate Table for the pressure in the Steam Generator and Pressurizer.
3. Locate the desired Actual Level under the column for the Average Containment Temperatures.
4. From the column headed "Indicated Level (%)"determine the indicated level which should be maintained to ensure the Actual Level is maintained at or above the Desired Value.

NOTE

  • If the computer is unavailable or the containment average temperature is considered to be unreliable, maintain the indicated level 35% above the desired level .
  • Salem Unit 1
                           --~--~-

APP 1-1 Rev. 11

TABLE 1

                                                                                       .1 4.L.

INDICATED STEAM GENERATOR LEVEL (%) vs. ACTUAL LEVEL ( %) AT 200 psig INDICATED ACTUAL S/G LEVEL ( %) AT TEMPERATURES LEVEL(%) 125 150 175 200 225 250 275 300 325 350 o.oo -17.89 -18.74 -19.68 -20.73 -21.88 -23.14 -24.50 -25.96 -27.51 -29.14 5.00 -13.61 -14.46 -15.41 -16.46 -17.61 -18.87 -20.22 -21.68 -23.23 -24.87 10.00 - 9.34 -10.19 -11.13 -12.18 -13.33 .-14.59 -15.95 -17.41 -18.96 -20.59 15.00 - 5.07 - 5.91 - 6.86 - 7.91 - 9.06 -10.32* -11. 68 -13.13 -14.68 -16.32 20.00 - 0.79 - 1. 64 - 2.58 - 3.63 - 4.79 - 6.04 - 7.40 - 8.86 -10.41 -12.05 25.00 3.48 2.64 1. 69 0.64 0.51 1. 77 3.13 4.58 6.14 7.77 30.00 7.76 6.91 5.96 4.92 3.76 2.51 1.15 0.31 1. 86 3.50 35.00 12.03 11. 18 10.24 9.19 8.04 6.78 5.42 3.96 2.41 0.78 40.00 16.31 15.46 14.51 13.46 12.31 11.05 9.70 8.24 6.69 5.05 45.00 20.58 19.73 18.79 17.74 16.59 15.33 13.97 12.51 10.96. 9.33 50.00 24.85 24.01 23.06 22.01 20.86 19.60 18.24 16.79 15.24 13.60 55.00 29.13 28.28 27.34 26.29 25.13 23.88 22.52 21. 06 19.51 17.87 60.00 33.40 32.56 31. 61 30.56 29.41 28.15 26.79 25.33 23.78 22.15 65.00 37.68 36.83 35.88 34.84 33.68 32.43 31. 07 29.61 28.06 26.42 70.00 41. 95 41. 10 40.16 39.11 37.96. 36.70 35.34 33.88 32.33 30.70 75.00 46.23 45.38 44.43 43.38 42.23 40.97 39.61 38.16 36.61 34.97 Salem Unit APP 1-2 Rpv. 11

TABLE 1 J 4. I. INDICATED ACTUAL S/G LEVEL ( %) AT TEMPER.l;\.TURES LEVEL(%) 125 150 175 200 225 250 275 300 325 350 80.00 50.50 49.65 48.71 47.66 46.51 45.25 43.89 42.43 40.88 39.25 85.00 54.77 53.93 52.98 51. 93 50.78 49.52 48.lfi 46.71 45. Hi 43.52 90.00 59.05 58.20 57.26 56.21 55.05 53.80 52.44 50.98 49.43 47.79 95.00 63.32 62.48 61. 53 60.48 59.33 5 8. 0'7 56.71 55.25 53.70 5?.. 0 7 100.00 67.60 66.75 65.80 64.76 63.60 62.35 60.99 59.53 57.98 56.34 C! :::I , ~~ nn ; + 1 ~pp 1 1 °RPV 11

TABLE 2 l 4. l-INDICATED STEAM GENERATOR LEVEL ( %) vs. ACTUAL LEVEL ( %) 200 PSIG INDICATED ACTUAL S/G LEVEL ( %) AT TEMPERATURE LEVEL ( %) 125 150 175 200 225 250 275* 300 325 350 o.oo -18.52 -19.41 -20.42 -21.54 -22.77 -24.10 -25.53 -27.06 -28.70 -30.46 5.00 -13.98 -14.88 -15.89 -17.01 -18.23 -19.56 -20.99 -22.53 -24.17 -25.93 10.00 - 9.45 -10.34 -11.35 -12.47 -13.70 -15.03 -16.46 -17.99 -19.64 -21.40 15.00 - 4.91 - 5.81 - 6.82 - 7.94 - 9.17 -1.0. 4 ~ -_11. 9 2 .-13. 4 6 . -15.10 -16.86 20.00 - 0.38 - 1. 27 - 2.29 - 3.41 - 4.63 - 5.96 -, 7.39 - 8.92 -10.57 -12.33 25.00 4.15 3.26 2.7.51 1. 13 - 0 .10 - 1. 42 - 2.85 - 4.39 - 6.03 - 7.79 30.00 8.69 7.79 6.78 5.66 4.44 3.11 1. 68 0.15 - 1. 50 - 3.26 35.00 13.22 12.33 11. 32 10.20 8.97 7.65 6 . .7.2 4.68 3.04 1. 28 40.00 17.76 16.86 15.85 14.73 13.51 12.18 10.75 9.21 7.57 5.81 45.00 22.29 21. 40 20.39 19.27 18.04 16.71 15.78 13.75 12.10 10.34 I I 50.00 / 261. 83 25.93 24.92' 23.80 22.58 21. 25 19.82 18.28 16.64 14.88

               /                                                                                                           .-./~*
             /

55.00 31 36 30 .. 4 7 29.46 28.33 27.11 25.78 24.35 22.82 21. 1 7 ,.,. 19. 41

                                                                                                                      ,/

60.00 35.89 35.00 33.99 32.87 31. 64 30.32 28.89 27.35 /.5.71 23.95 65.00 40.43 39.54 38.52 37.40 36.18 34.85 33.42 31.89 ~~ 0 . 24 28.48 70.00 44.96 44.07 43.06 41. 94 40.71 39.39 37.96 36.42 34.78 33.02 75.00 49.50 48.60 47.59 46.47 45.25 43.92 42.49 40.9fi 39.31 37.55

                                                                       ,/

C::::i 1 om Tln it- 1 l>PP.1-Ll °Rpv - 11

TABLE 2 INDICATED ACTUAL S/G LEVEL ( %) AT TEMPERATURE LEVEL (%) 125 150 175 200 225 250 275 300 325 350 80.00 54.03 53.14 52.13 51. 01 49.78 48.45 47.03 45.49 43.85 42.0? 85.00 58.57 57.67 56.66 55.54 54.32 52.99 51. 56 50.02 48.38 46.62 90.00 63.10 62.21 61. 20 60.08 58.85 57.52 56.09 54.56 52.91 51. 15 95.00 67.64 66.74 65.73 64.61 63.38 62 .*06 60.63 59.09 57.45 55.69 100.00 72.17 71. 28 70.26 69.14 67.92 66.59 65.16 63.63 61. 98 60.22

. 'J
/~*)
                                     *. J

TABLE 3

                                                                                                                .l 4. L INDICATED STEAM GENERATOR LEVEL(%) vs. ACTUAL LEVEL(%) AT- 600psig INDICATED                                 ACTUAL.S/G LEVEL(%) AT TEMPERATURE LEVEL(%)                    125      150       175         200       225       250      275       300     325         350 0.00                  -19.27  -20.19    -21. 25  -22.44       -23.73  -25.12     -26.61   -?.8.21  -29.92     -31.77 5.00                  -14.50  -15.42    -16.49   -17.67       -18.96  -20 .* 36  -21.85   -23.44   -25.16     -27.00 10.00                     - 9.74  -10.66    -11. 72  -12.91       -14.20  -15.59     -17.08   -18.68   -20.39     -27..24 15.00                     - 4.97  - 5.89    - 6.96   ":""* 8. 14  - 9.43  ...:.10.82 -J.2.32  -13.91   -15.63     -17.47 20.00                     - 0.21  -  1.13   -  2.19  -     3.38   - 4.67  - 6.06     - 7.55   -   9.15 -10.86     -12.71 25.00                      4.56     3.64      2.57        1. 39     0.10 - 1. 29    -  2.78  --  4.38 -  6.10    -   7.94 30.00                       9.32     8.40      7.34        6.16      4.86      3.47     1. 98     0.38 -  1. 33   -   3.18 35.00                    14.09     13.17     12.11      10.92       9.63      8.24     6.75      5.15    3.44        1. 59 40.00                    18.86     17.94     16.87      15.69     14.40     13.00     11. 51     9.92    8.20        6.36 45.00                    23.62     22.70     21. 64     20.45     19.16     17.77     16.28     14.68   12.97      11. 12 50.00                    28.39     27.47     26.40      25.22     23.93     22.53     21. 04    19.45   17.73      15.89 55.00                    33.15     32.23     31.17      29.98     28.69     27.30     25.81     24.21   22.50      7.0.65 60.00                    37.92     37.00     35.93      34.75     33.46     32.07     30.58     28.98   27.96      25.42 65.00                    42.68     41. 76    40.70      39.52     38.22     36.83     35.34     33.74   32.03      30.18 70.00                    47.45     46.53     45.47       44.28    42.99     41. 60    40.11     38.51   36.80      34.95 c:: :::> 1 i=>m Tln i +- 1                                      ~PP  1-n                                     RP.v    l1

TABLE 3 J_ 4. L INDICATED ACTUAL S/G LEVEL(%) AT TEMPERATURE LEVEL(%) 125 150 175 200 225 250 275 300- 325 350 75.00 52.22 51. 30 50.23 49.05 47.75 46.36 44.87 43.7.8 41. 56 39.72 80.00 56.98 56.06 55.00 53.81 52.52 51.13 49.64 48.04 46.33 44.48 85.00 61. 75 60.83 59.76 58.58 57.29 55.89 54.40 52.81 51. 09 49.25 90.00 66.51 65.59 64.53 63.34 62.05 60.66 59.17 57.57 55.86 54.01 95.00 71. 28 70.36 69.29 68.11 66.82 65.43 63.93 62.34 60.62 58.78 100.00 76.04 75.12 74.06 72.88 71. 58 70.19 68.70 67.10 65.39 63.54 C:: ;::i 1 om TTn i +- 1 ~pp 1-7 RP.v. 11

TABLE 4 I 4. ~ INDICATED STEAM GENERATOR LEVEL(%) vs. ACTUAL LEVEI, ( %) AT 800 psi a INDICATED ACTUAL S/G LEVEL°(%) AT TEMPERATURE LEVEL(%) 125 150 175 200 225 250 275 300 325 350 o.oo -20.20 -21.11 -22.18 -23.39 -24.72 -26.16 -27.71 -29.36 -31.12 -33.00 5.00 -15.20 -16.11 -17.18 -18.39 -19.72 . -21.16 -22.71 -24.36 -26.12 -28.00 10.00 -10.20 -11.11 -12.18 -13.39 -14.72 -16.16 -17.71 -19.36 -21.12 -23.00 15.00 - 5.20 - 6.11 - 7.18 - 8.39 - 9.72 -11.16 -12.71 -14.36 -16.12 -18.00 20.00 - 0.20 - 1. 11 - 2.18 - 3.39 -*4.72 - 6.16 - 7.71 - 9.36 -11.12 -13.00 25.00 4.80 3.89 2.82 1. 61 0.28 - 1.16 - 2.71 - 4.36 - 6.12 - 8.00 30.00 9.80 8.89 7.82 6.61 5. 28 . 3.84 2.29 0.64 - 1. 12 - 3.00 35.00 14.80 13.89 12.82 11. 61 10.28 8.84 7.29 5.64 3.88 7.. 0 0 40.00 19.80 18.89 17.82 16~61 15.23 13.84 12.29 10.64 8.88 7.00 45.00 24.80 23.89 22.82 21. 61 20.28 18.84 17.29 15.64 13.88 12.00 50.00 29.80 28.89 27.82 26.61 25.28 23.84 22.29 20.64 18.88 17.00 55.00 34. 80 . 33.89 32.82 31. 61 30.28 28.84 27.29 25.64 23.88 22.00 60.00 39.80 38.89 37.82 36.61 35.28 33.84 32.29 30.64 28.88 7.7.00 65.00 44.80 43.89 42.82 41. 61 40.28 38.84 37.29 35.64 33.88 32.00 70.00 49.80 48.39 47.32 46.61 45.28 43.84 42.29 40.64 38.88 37.00 C:"' 1 om TTn ; +- 1 ~PP 1-R Rpu 11

TABLE 4

                                                                                                 .L  4. /,

INDICATED STEAM GENERATOR-LEVEL(%) vs. ACTUAL LEVEL(%) AT 800 psi a INDICATED ACTUAL S/G LEVEL(%) AT TEMPERATURE LEVEL(%) 125 150 175 200 225 250 275 300 325 350 75.00 54.80 53.89 52.82 51. 61 50.28 48.84 47.29 45.64 43.88 42.00 80.00 59.80 58.89 57.82 56.61 55.28 53.84 52.29 so*. 64 48.88 47.00 85.00 64.80 63.89 62.82 61. 61 60.28 58.84 57.29 55.64 53.88 52.00 90.00 69.80 68.89 67.82 66.61 65J28 63.84 62.29 60.64 58.88 57.00 95.00 74.80 73.89 72.82 71. 61 70.28 68.84 67.29 65.64 63.88 62.00 100.00 79.80 78.89 77.88 76.61 75.28 73.84 72.29 70.64 68.88 67.00 C: ::o 1 ~""' TTn ; +- 1 li.DD 1 Q °RPV - 11

TABLE 5 INDICATED STEAM GENERATOR LEVEL(%) vs. ACTUAL LEVEL(%) AT 1000 psi a INDICATED ACTUAL S/G LEVEL(%) AT TEMPERATURE LEVEL(%) 125 150 175 200 225 250 275 300 325 350 0.00 -21. 23 -22.20 -23.35 '-24.63 -26.04 -27.56 -29.18 -30.92 -32.79 -34.79 5.00 -16.00 -16.97 -18.12 -19.40 -20.81 -22.33 -23.95 -25.69 -27.55 -29.55 10.00 -10.77 -11. 74 -12.88 -16.17 -15.58 -17.09 -18.72 -20.46 -22.32 -24.32 15.00 - 5.54 - 6.51 *- 7.65 - 8.94 -10.35 -11. 86 -13.49 -15.23 -17.09 -19.09 20.00 - 0.31 - 1. 28 - 2.42 - 3.71 - 5.11 - 6.63 - 8.26 -10.00 -11.86 -13.86 25.00 4.92 3.95 2.81 1. 52 0.12 - 1. 40 - 3.03 - 4.77 - 6.63 - 8.63 30.00 10.15 9.18 8.04 6.75 5.35 3.83 2.20 0.46 - 1. 40 - 3.40 35.00 15.38 14.41 13.27 11. 99 *10.58 '9.06 7.43 5.69 3.83 1. 83 40.00 20.62 1'9. 6 4 18.50 17.22 15.31 14.29 12.66 10.92 9.06 7.06 45.00 25.85 24.87 23.73 22.45 21. 04 19.52 17.90 16.16 14.29 12.29

  • L:.; :*

50.00 31. 08 30.11 28.96 27.68 *26.27 24.75 23.18 21. 39 19.52 17.52 55.00 36.31 35.34 34.19 32.91 31. 50 29.98 28.36 26.62 24.75 22.76 60.00 41. 54 40.57 39.43 38.14 36.73 35.22 33.59 31. 85 29.99 27.99 65.00 46.77 45.80 44.66 43.37 41. 96 40.45 38.83 37.08 35.22 33.22 70.00 52.00 51. 03 49.89 48.60 47.20 45.68 44.05 42.-31 40.45 33.45 R. . l

  • //
          /

I

                \

TABLE 5

                                                                                       ;;~/~
  • i
                  \I
                                                                                   /
                                                                                     /

INDICATED STEAM GENERATOR LEVEL(%) vs. ACTUAL LEVEL(%) AT 1000 psi£ INDICATED ACTUAL S/G LEVEL(%) AT TEMPERATURE LEVEL(%) I 125 150 175 200 225 250 275 300 325 350 75.00 57.23 56.26 55.12 53.83 52.43 50.91 49.28 47.54 45.68 43.68 -80.00 62.46 61. 49 60.35 59.06 57.66 56.14 54.51 .52.77 50.91 48.91 85.00 67.69 66.72 65.58 64.30 62.89 ~l. 37 59.74 58.00 56.14 54.14 90.00 72.93 71. 95 70.81 69.53 68.12 66.60 64.97 63.23 61. 37 59.37 95.00 78.16 77.18 76.04 74.76 73.35 71.83 70.21 68.47 66.60 64.60 100.00 83.39 82.42 81. 27 79.99 78.58 77.06 75.44 73.70 71. 83 69.83

  • J TABLE 6 1.-4. L INDICATED PRESSURIZER LEVEL(%) vs. ACTUAL LEVEL(%) AT 500 psi a INDICATED ACTUAL PRZ LEVEL(%) AT CONTAINMENT TEMPERATURE (Deg F)

LEVEL(%) 125 150 175 200 225 250 275 300 325 350 0.00 -10.25 -11.16 -12.20 -13.35 -14.61 -15.97 -17.43 -19.00 -20.69 -22.52 5.00 - 7.15 - 8.06 - 9.10 -10.25 -11. 51 -12.87 -14.33 -15.90 -17.59 -19.42 10.00 - 4.05 - 4.96 - 6.00 - 7.15 - 8.41 - 9.77 -11. 23 -12.81 -14.50 -16.32 15.00 - 0.95 1. 86 - 2.90 - 4.06 - 5.31 - 9.69 - 8 . 9. 71. -11.40 -13.22 20.00 2.15 1. 24 0.20 - 0.96 - 2.21 - 3.97 - 5.04 - 6.61 - 8.30 -10.12 25.00 5.25 4.34 3.30 2.14 0 .. 88 - 0.48 - 1. 94 - 3.51 - 5.20 - 7.02 30.00 8.35 7.48 6.40 5.24 3.93 2.62 l. 16 - 0.41 - 2.10 - 3.92 35.00 11. 44 10.53 9.49 8.34 7.08 5.72 4.26 2.69 1. 00 - 0.82 40.00 14.54 13.63 12.59 11. 44 10.18 8.82 7.36 5.79 4.10 2.27 45.00 17.64 16.73 15.69 14.54 13.28 11. 92 10.46 8.89 7.20 5.37 50.00 20.74 19.83 18.79 17.64 16.38 15.02 13.56 11. 99 10.30 8.47 55.00 23.84 22.93 21. 89 20.74 19.48 18.12 16.66 15.08 13.39 11. 57 60.00 26.94 26.03 24.99 23.83 22.58 21. 22 19.75 18.18 16.49 14.67 65.00 30.04 29.13 28.09 26.93 25.68 24.32 22.85 .?-1.28 19.59 17.77 70.00 33.14 32.?.3 31.19 30.03 28.77 27.41 25.95 24,38 22.69 20.87 C::"' 1 Pm TTn i +- 1 APP 1-1? Rev_ 11

1

  • TABLE 6 J_ 7.f. 7.

INDICATED PRESSURIZER LEVEL(%) vs. ACTUAL LEVEL(%) AT 500 psi a INDICATED ACTUAL PRZ LEVEL(%) AT CONTAINMENT TEMPERATURE(Deg F)

     .LEVEL(%)                   125      150     175     200        225      250   275    300     325             350 75.00                    36.24    35.33   34.29   33.13      31. 87   30.51 29.05  27.48   25.79        23.97 80.00                    39.33    38.42   37.38   36.23      34.97    33.61 32.15  30.58   28.89        27.07 85.00                    42.43    41.52   40.48   39.33      38.07    36.71 35.29  33.68   31. 99       30.16 90.00                    45.53    44.62   41. 58  42.43      41. 17   39.81 38.35  36.78   35.09       33.26 95.00                    48.63    47.72   46.68   45.53      44.27    42.91 41. 45 39.88   38.19       36.36 100.00                   51. 73   50.82   49. 78  48.63      47.37    46.01 44.55  42.97   41. 28      39.46 I

I C::::;:, 1 i:>m TTn i t- 1 11, pp 1 -1 ~ Rpv 11

TABLE 7 _L-LJ:

  • L.

INDICATED PRESSURIZER LEVEL(%) vs. ACTUAL LEVEL(%) AT 1000 psi a INDICATED ACTUAL PRZ LEVEL(%) AT CONTAINMENT TEMPERATURE (Deg F) LEVEL(%) 125 150 175 200 225 250 275 300 325 350 0.00 -11.48 -12.46 -13.61 -14.90 -16.32 -17.85 -19.48 -21.23 -23.11 -25.12 5.00 - 8.00 - 8.98 -10.13 -11.42 -12.83 -14.36 -16.00 -17.75 -19.62 -21. 63 10.00 - 4.51 - 5.49 - 6.64 - 7.93 - 9.35 -10.88 -12.51 -14.26 -16.14 -18.15 15.00 1. 03 2.01 3.16 4.45 5.87 7.39 9.03 -10.78 -12.65 -14.67 20.00 2.45 1. 48 0.33 - 0.97 - 2.38 - 3.91 - 5.55 - 7.30 - 9.17 -11.18 25.00 5.94 4.96 3.81 2.52 1.10 - 0.42 .;... 2.06 - 3.81 - 5.69 - 7.70 30.00 9. 42' 8.44 7.30 6.00 4.59 3.06 1. 42 - 0.33 - 2.20 - 4.21 35.00 12.91 11. 93 10.78 9.49 8.07 6.54 4.91 3.16 1. 28 - 0.73 40.00 16.39 15.41 14.26 12.97 11. 56 10.03 8.39 6.64 4.77 2.75 45.00 19.87 18.90 17.75 16.46 15.04 13.51 11. 87 10.12 8.25 6.24 50.00 23.36 22.38 21. 23 19.94 18.52 17.00 15.35 13.61 11. 73 9.72 55.00 26.84 25.87 24.72 23.42 22.01 20.48 18.84 17.09 15.22 13. :n 60.00 30.33 29.35 28.20 26.91 25.49 23.96 22.33 20.58 18.70 16.69 65.00 33.81 32.83 31. 68 30.39 28.98 27.45 25.81 24.06 22.19 20.18

70. 00 . 37.30 36.32 35.17 33.83 32.46 30.93 29.30 27.55 25.67 23.66 c:,,, 1 ~~ n . . . ; +- 1 'A pp 1 1 L1
  • TABLE 7
                                                                                                  -'- 4. ,~

INDICATED PRESSURIZER LEVEL(%) vs. ACTUAL LEVEL(%) AT 1000 psia INDICATED ACTUAL PRZ LEVEL(%) AT CONTAINMENT TEMPERATURE (Deg F) LEVEL(%) 125 150 175 200 225 250 275 300 3 /. 5 350 75.00 40.78 39.80 38.65 37.36 35.94 34.42 32.78 31. 03 29.16 27.14 .80. 00 44.26 43.29 42.14 40.84 39.43 37.90 36.26 34.51 32.64 30.63 85.00 47.75 46.77 45.62 44.33 42.91 41. 38 39.75 38.90 36.12 34.11 90.00 51.23 50.25 49.10 47.81 46.40 44.87 43.23 41. 48 39.61 37.60 95.00 54.72 53.74 52.59 51. 30 49.88 48.35 46.72 44.97 43.09 41. 08 100.00 58.20 57.22 56.02 54.78 53.36 51. 84 50.20 48.45 46.58 44.56 C:: ;:i 1 om Tln i t- 1 n PP 1 -1 i:;

  • Rpv 11

TABLE 8 INDICATED PRESSURIZER LEVEL(%) vs. ACTUAL LEVEL(%) AT 1500 psi a INDICATED ACTUAL PRZ LEVEL(%) AT CONTAINMENT TEMPERATURE (Deg F) LEVEL(%) 125 150 175 200 225 250 275 300 325 350 o.oo -13.61 -14.73 -16.03 -17.48 -19.07 -20.79 -22.64 -24.61 -26.71 -28.95 5.00 - 9.67 -10.80 -12.09 -13.54 "'-15.13 -16.85 -18.70 720.68 -22.78 -25.01 10.00 - 5.74 - 6.36 - 8.16 - 9.61 -11.20 -12.92 -14.77 -16.74 -18.84 -21.08 15.00 - 1. 80 - 2.92 - 4.22 - 5.67 - 7.26 - 8.98 -10.83 -12.80 -14.91 -17.14 20.00 2.14 1. 01 - 0.28 - 1. 78 - 3.32 - 5.05 - 6.89 - 8.87 -10.97 -13.21 25.00 6.07 4.95 3.65 2.20 0.61 - 1.11 - 2.96 - 4.93 - 7.04 - 9.27 30.00 10.01 8.88 7.59 6.14 4.55 2.83 0.98 - 1. 00 - 3.10 - 5.33 c 35.00 13.94 12.82 11. 52 10.07 8.48 6.76 4.91 2.94 0.84 - 1. 40 40.00 17.88 16.75 15.46 14.01 12.42 10.70 8.85 6.87 4.77 2.54 45.00 21. 82 20.69 19.39 17.94 16.36 14.63 12.79 10.81 8.71 6.47 50.00 25.75 24.63 23.33 21. 83 20.29 18.57 16.72 14.75 12.64 10.41 55.00 29.69 28.56 27.27 25.82 24.23 22.51 20.66 18.68 16.58 14.35 60.00 33.62 32.50 31. 20 29.:75 28.16 26.44 24.59 22.62 20.52 18.28 65.00 37.56 35.43 35.14 33.69 32.10 30.38 28.58 26.55 24.45 22.22* 70.00 41. 49 40.37 39.07' 37.62 36.03 34.31 32.46 30.49 28.39 26.15

TABLE 8

                                                                                    *  ,. /

INDICATED PRESSURIZER LEVEL(%) vs ACTUAL LEVEL(%) AT 1500 psia INDICATED ACTUAL PRZ LEVEL(%) AT CONTAINMENT TEMPERATURE (Deg F) LEVEL(%) 125 150 175 200 225 250 275 300 325 350 75.00 45.43 44.30 43.01 41. 56 39.97 38.25 36.40 34.43 32.32 30.09 80.00 49.37 48.24 46.94 45.50 43.91 42.18 40.84 38.36 "36.26 34.02 85.00 53.30 52.18 50.88 49.43 47.84 46.12 44.27 42.30 40.19 37.96 90.00 57.24 56.11 54.32 53.37 51.78 50.06 48.21 46.23 44.13 41. 90 95.00 61.17 60.05 58.75 57.30 55.71 53.99 52.14 50.17 48.07 45.83 100.00 65.11 63.98 62.69 61. 24 59.65 57.93 56.08 54.10 52.00 49.77

        /

I

  • I- .

TABLE 9 INDICATED PRESSURIZER LEVEL(%) vs. ACTUAL LEVEL(%) AT 2000 psi a INDICATED ACTUAL. PRZ LEVEL(%) AT CONTAINMENT TEMPERATURE (Deg F) LEVEL(%) 125 150 175 200 225 250 275 300 325 350 0.00 -17.39 -18.69 -20.19 -21. 85 -23.67. -25.64 -2T. 75 -30.00 -32.40 -34.97 5.00 -12.83 -14.13 -15.63 -17.29 -19.11 -21. 08 -23.19 -25.44 -27.84 -30.41 10.00 - 8.27 - 9.57 -11.07 -12.73 -14.35 -16.52 -18.61 -20.88 -23.28 -25.85 15.00 - 3.71 - 5.01 - 6:51 - 8.17 - 9.99 -11. 96 -14.07 -16.32 -18.72 -21.29 20.00 0.85 0.45 1. 95 3.61 5.43 7.40 9.51 -11. 76 -14.16 -16.73 25.00 . 5. 41 4.11 .2. 61 0.95 - 0.84 - 2.84 - 4.95 - 7.20 - 9.60 -12.17 30.00 9.97 8.67 7.17 5.51 3.69 1. 72 - 0.39 - 2.64 - 5.04 - 7.61 35.00 14.53 13.23 11. 73 10.07 8. 25 . 6.28 4.17 1. 92 - 0.48 - 3.05 40.00 19.09 17.79 *16.29 14.63 12.81 10.84 . 8. 7 3 6.48 4.08 1.Sl 45.00 23.65 22.35 20.85 19.19 17.37 15.40 13.29 11. 04 8.64 - 6. 07 50.00 28.21 26.91 25.41 23.75 21. 93 19.96 17.85 15.60 13.20 10.63 55.00 32.77 31. 47 29.97. *28.31* 26.49 24.52 22.41 20.16 17.76 15.19 60.00 37.33 36.03 34.53 32.87 31. 05 29.03 26.97 24.72 22.32 19.75 65.00 41. 89 40.59 39.09 37.43 35.61 33.64 31. 53 29.28 26.88 24.31 70.00 46.45 45.15 43.65 41. 99 40.17 38.20 36.09 33.84 31. 44 28.37

TABLE 9 INDICATED PRESSURIZER LEVEL(%) vs. l\.CTUAL LEVEL(%) AT 2000 psi a INDICATED ACTUAL PRZ LEVEL(%) AT CONTAINMENT TEMPERATURE (Deg F) LEVEL(%) 125 150 175 200 225 250 275 300 325 350 75.00 51. 01 49.71 48.21 46.55 44.73 42.76 40~65 38.40 36.00 33.43 80.00 55.57 54.27 52.77 51.11 49.29 47.32 45.21 42.96 40.56 37.99 85.00 60.13 58.83 57.33 55.67 53.85 51. 88 49.77 47.52 45.12 42.55

   *90.00     64.69    63.39   61. 89  60.23   58.41     56.44   54.33   52.08   49.68   47.11 95.00     69.25    67.95   66.45   64.79   62.97     61. 00  58.89   56.64   54.24   51. 67 100.00    73.81    72.51   71. 01  69.35   67.53     65.56   63.45   61. 20  58.80   56.23

TABLE 10 J. 4. L INDICATED PRESSURIZER LEVEL(%) vs. ACTUAL LEVEL(%) AT 2250 psi a INDICATED ACTUAL PRZ LEVEL(%) AT CONTAINMENT TEMPERATURE (Deg F) LEVEL(%) 125 150 175 200 225 250 275 300 325 350 0.00 -20.42 -21. 83 -23.50 -25.35 -27.35 -29.47 -31.76 -34.25 -37.02 -40.16 5.00 -15.42 -16.83 -18.50 -20.35 -22.34 -24.47 - 26.75 -29.24 -32.0l -35.16 10.00 -10.41 -11. 82 -13.50 -15.35 -17.34 -19.47 -21. 75 -24.24 -7.7.01 -30.16 15.00 - 5.41 - 6.82 - 8.49 -10.35 -12.34 -14.47 -16.75 -19.7.4 -/.2.01 -25.15 20.00 - 0.41 - 1. 82 - 3.49 - 5.34 - 7.34 *- 9.46 -11. 75 -14.24 -17.01 -20.15 25.00 4.59 3.18 1. 51 - 0.34 - 2.34 - 4.46 - 6.74 - 9.23 -12.01 -15.15 30.00 9.59 8.19 6.51 4.66 2.67 0.54 - 1. 74 - 4.23 - 7.00 -10.15 35.00 14.60 13.19 11. 52 9.66 7.67 5.54 3.26 0.77 - 2.00 - 5.15 40.00 19.60 18.19 16.52 14.67 12.67 10.55 8.26 .5. 77 3.00 - 0.14 45.00 24.60 23.19 21. 52 19.67 17.67 15.55* 13.27 10.78 8.00 4.86 50.00 29.60 28.19 26.52 24.67 22.68 20.55 18.27 15.78 13.01 9. 86 55.00 34.61 33.20 31. 53 29.67 27.68 25.55 23.27 20.78 18.01 14.86 60.00 39.61 38.20 36.58 34.67 32.68 30.55 28.27 25.78 23.01 19.37 65.00 44.61 43.20 41. 53 39.68 37.68 35.56 33.27 30.78 28.01 24.87 70.00 49.61 48.20 46.52 44.68 42.69 40.56 38.28 35.79 33.02 29.37 Salem Unit 1 APP 1-20 Rev 11

TABLE 10 INDICATED PRESSURIZER LEVEL(%) vs. ACTUAL LEVEL(%) AT 2250 psi a INDICATED ACTUAL PRZ LEVEL(%) AT CONTAINMENT TEMPERATURE (Deg F) LEVEL(%) 125 150 175 200 225 250 275 300 325 350 75.00 54.62 53.21 51.53 49.68 47.69 45.56 43.28 40.79 38.02 34.87 80.00 59.62 58.21 56.54 54.68 52.69 50.56 48.28 45.79 43.02 39.88 85.00 64.62 63.21 61. 54 59.62 57.69 55.57 53.28 50.79 48.02 44.88 90.00 69.62 68.21 66.54 64.69 62.69 60.57 58.29 55.80 53.02 49.99 95.00 74.63 73.22 71. 54 69.69 67.70 .65.57 63.29 60.80 58.03 54.88 100.00 79.63 78.22 76.55 74.69 72.70 70.57 68.29 65.80 63.03 59.88

TABLE 11 j_ l.!. /.

                                                                                                                    *   ~

INDICATED PRESSURIZER LEVEL(%) vs. ACTUAL LEVEL(%) AT 2500 psia INDICATED ACTUAL PRZ LEVEL(%) AT CONTAINMENT TEMPERATURE (Deg F) LEVEL(%) 125 150 175 200 225 250 275 300 325 350 o.oo -24.27 -26.62 -28.44 -30.46 -32.69 -35.12 -37.74 -40.54 -43.47 -46 . .55

5. 0 0 . -19.35 -21. 00 -22.82 -24.84 -27.07 -29.50 -32.12 -34.92 -27.87 -40.93 10.00 -13.73 -15.38 -17.20 -19.22 -21.45 -23.88 -26.50 -29.30 -32.25 -35.31 15.00 - 8.11 - 9.76 -11. 58 -13.60 -15.83 -18.26 -20.88 -23.68 -26.63 -29.69 20.00 - 2.49 - 4.14 - 5.96 - 7.93 *-10.21 -12.64 -15.26 -18.06 -:n. 01 -24.07 25.00 3.13 1. 48 - 0.34 - 2.36 - 4.59 - 7.02 - 9.64 -12.44 -:t.5. 3 9 -18.45 30.00 8.75 7.10 5.28 3.26 1°. 0 3 - 1. 40 - 4~02 - 6.82 - 9.77 -12.83 35.00 14.37 12.72 10.90 8.88 6.65 4.22 1. 60 - 1. 7.0 - 4.15 - 7.21 40.00 19.99 18.34 16.52 14.50 12.27 9.84 7.22 4.42 1. 4 7 - 1. 59 45.00 25.61 23.96 22.14 20.12 17.89 15.46 12.84 10.04 7.09 4. 03 50.00 31. 23 29.58 27.76 25.74 23.51 21. 08 18.46 15.66 12.71 9. 65 55.00 36.85 35.20 33.38 31. 36 29.13 26.70 24.08 21. 28 18.33 15.27 60.00 42.47 40.82 39.00 36.98 34.75 32.32 29.70 26.90 23.95 20.39 65.00 48.09 46.44 44.62 42.60 40.37 37.94 35.32 32.52 29.57 26.51 70.00 53.71 52.06 50.24 48.22 45.99 43.56 40.94 38.14 35.19 32.13 I*

I I I

    ~riJem   Unit 1                                   APP 1-22                                        Rev. 11 1
  • TABLE 11
                                                                                               * \... ,..

INDICATED PRESSURIZER LEVEL(%) vs. ACTUAL LEVEL(%) AT 2500 psi a INDICATED ACTUAL PRZ LEVEL(%) AT CONTAINMENT TEMPERATURE (Deg F) LEVEL(%) 125 150 175 200 225 250 275 300 325 350 75.00 59.33 57.68 55.86 .53.84 51. 61 49.18 46.56 43.76 40.81 37.15 80.00 64.95 63.30 61. 48 59.* 46 57.23 54.80 52.18 49.38 46.43 43.37 85.00 70.57 68.92 67.10 . 65.08 62.85 60.42 57.80 55.00 52.05 48.99 I

 . j
    !  90.00     76.19    74.54   72.72     70.70     68.47  66. 0.4 63.42 60.62   57.67   54.61 95.00     81. 81   80.16   78.34. 76.32     74.09  71. 66  69.04 66.24   63.29   60.23 100.00    87.43     85~78  83.96     81. 94    79.71  77.28   74.66 71. 86  68.91   65.85

Appendix E Integrated Operating Procedures IOP-2, Cold Shutdown to Hot Standby IOP-3, Hot Standby to Minimum Load

  • }}