MONTHYEARML20217K4591999-09-30030 September 1999 Monthly Operating Repts for Sept 1999 for Vogtle Electric Generating Plant,Units 1 & 2.With ML20216E5061999-08-31031 August 1999 Monthly Operating Repts for Aug 1999 for Vegp,Units 1 & 2. with ML20210P9841999-07-31031 July 1999 Monthly Operating Repts for July 1999 for Vogtle Electric Generating Plant,Units 1 & 2.With ML20209H1211999-06-30030 June 1999 Monthly Operating Repts for June 1999 for Vogtle Electric Generating Plant,Units 1 & 2.With ML20195G1731999-05-31031 May 1999 Monthly Operating Repts for May 1999 for VEGP Units 1 & 2. with ML20206N2141999-04-30030 April 1999 Monthly Operating Repts for Apr 1999 for Vogtle Electric Generating Plant,Units 1 & 2.With ML20205Q8081999-03-31031 March 1999 Monthly Operating Repts for Mar 1999 for Vegp,Units 1 & 2. with ML20206C2291999-03-31031 March 1999 Revised Monthly Operating Repts for Mar 1999 for Vogtle Electric Generating Plant,Units 1 & 2 ML20207K6051999-02-28028 February 1999 Monthly Operating Repts for Feb 1999 for Vogtle Electric Generating Plant,Units 1 & 2.With ML20199E7561998-12-31031 December 1998 Monthly Operating Repts for Dec 1998 for Vogtle Electric Generating Plant,Units 1 & 2.With ML20198B8571998-11-30030 November 1998 Monthly Operating Repts for Nov 1998 for Vogtle Electric Generating Plant,Units 1 & 2.With ML20195H2131998-10-31031 October 1998 Monthly Operating Repts for Oct 1998 for Vogtle Electric Generating Station,Units 1 & 2.With ML20154L5681998-09-30030 September 1998 Monthly Operating Repts for Sept 1998 for Vegp,Units 1 & 2 ML20151W3681998-08-31031 August 1998 Monthly Operating Repts for Aug 1998 for Vogtle Electric Generating Plant Units 1 & 2.With ML20154L5721998-08-31031 August 1998 Corrected Page from MOR for Aug 1998 for Vegp,Unit 2 ML20237D2051998-07-31031 July 1998 Monthly Operating Repts for July 1998 for Vogtle Electric Generating Plant Units 1 & 2 ML20236P6991998-06-30030 June 1998 Monthly Operating Repts for June 1998 for Vogtle Electric Generating Plant,Units 1 & 2 ML20249A3911998-05-31031 May 1998 Monthly Operating Repts for May 1998 for Vogtle Electric Generating Plant ML20249A3931998-04-30030 April 1998 Revised MOR for Apr 1998 for Vogtle Electric Generating Plant Unit 1 ML20247F3841998-04-30030 April 1998 Monthly Operating Repts for Apr 1998 for Vogtle Electric Generating Plant,Units 1 & 2 ML20216D6141998-03-31031 March 1998 Monthly Operating Repts for Mar 1998 for Vogtle Electric Generating Plant,Units 1 & 2 ML20216E2421998-02-28028 February 1998 Monthly Operating Repts for Feb 1998 for Vogtle Electric Generating Plant,Units 1 & 2 ML20202G5441998-01-31031 January 1998 Monthly Operating Repts for Jan 1998 for Vogtle Electric Generating Plant,Units 1 & 2 ML20198L6471997-12-31031 December 1997 Monthly Operating Repts for Dec 1997 for Vogtle Electric Generating Plant,Units 1 & 2 ML20203H0601997-11-30030 November 1997 Monthly Operating Repts for Nov 1997 for Vegp,Units 1 & 2 ML20199B6301997-10-31031 October 1997 Monthly Operating Repts for Oct 1997 for Vogtle Electric Generating Plant,Units 1 & 2 ML20217H5991997-09-30030 September 1997 Monthly Operating Repts for Sept 1997 for Vogtle Electric Generating Plant,Units 1 & 2 ML20216H6071997-08-31031 August 1997 Monthly Operating Repts for Aug 1997 for Vogtle Electric Generating Plant ML20210K5081997-07-31031 July 1997 Monthly Operating Repts for July 1997 for VEGP ML20140D7301997-05-31031 May 1997 Monthly Operating Repts for May 1997 for Vogtle Electric Generating Plant ML20141D8531997-04-30030 April 1997 Monthly Operating Repts for Apr 1997 for Vogtle Electric Generating Plant Units 1 & 2 ML20137T6191997-03-31031 March 1997 Monthly Operating Repts for Mar 1997 for Vogtle Electric Generating Plant ML20136G3471997-02-28028 February 1997 Monthly Operating Repts for Feb 1997 for Vogtle Electric Generating Plant Units 1 & 2 ML20134H3481997-01-31031 January 1997 Monthly Operating Repts for Jan 1997 for Vogtle Electric Generating Plant,Units 1 & 2 ML20133F6551996-12-31031 December 1996 Monthly Operating Repts for Dec 1996 for Vogtle Electric Generating Plant,Unit 1 & 2 ML20132B9671996-11-30030 November 1996 Monthly Operating Repts for Nov 1996 for Vogtle Electric Generating Plant Units 1 & 2 ML20134K7361996-10-31031 October 1996 Monthly Operating Repts for Oct 1996 for Vogtle Electric Generating Plant,Units 1 & 2 ML20128N1541996-09-30030 September 1996 Monthly Operating Repts for Sept 1996 for Vogtle Electric Generating Plant,Units 1 & 2 ML20117N1731996-08-31031 August 1996 Monthly Operating Repts for Aug 1996 for Vogtle Electric Generating Plant Units 1 & 2 ML20116J3461996-07-31031 July 1996 Monthly Operating Repts for Jul 1996 for Vogtle Electric Generating Plant Units 1 & 2 ML20115E9821996-06-30030 June 1996 Monthly Operating Repts for June 1996 for Vogtle Electric Generating Plant ML20112H6411996-05-31031 May 1996 Monthly Operating Repts for May 1996 for Vogtle Electric Generating Plant Units 1 & 2 ML20111B2461996-04-30030 April 1996 Monthly Operating Repts for Apr 1996 for Vogtle Electric Generating Plant Units 1 & 2 ML20101R0251996-03-31031 March 1996 Monthly Operating Repts for Mar 1996 for Vogtle Electric Generating Plant ML20100R2701996-02-29029 February 1996 Monthly Operating Repts for Feb 1995 for Vogtle Electric Generating Plant ML20100F2071996-01-31031 January 1996 Monthly Operating Repts for Jan 1996 for Vogtle Electric Generating Plant Units 1 & 2 ML20096C3051995-12-31031 December 1995 Monthly Operating Repts for Dec 1995 for Vogtle Electric Generating Plant,Units 1 & 2 ML20095E0201995-11-30030 November 1995 Monthly Operating Repts for Nov 1995 for Vogtle Electric Generating Plant ML20094J0741995-10-31031 October 1995 Monthly Operating Repts for Oct 1995 for Vogtle Electric Generating Plant Units 1 & 2 ML20093F5031995-09-30030 September 1995 Monthly Operating Repts for Sept 1995 for Vogtle Electric Generating Plant 1999-09-30
[Table view] Category:TEXT-SAFETY REPORT
MONTHYEARML20217K4591999-09-30030 September 1999 Monthly Operating Repts for Sept 1999 for Vogtle Electric Generating Plant,Units 1 & 2.With ML20217K8041999-09-30030 September 1999 Rev 1 to Vegp,Unit 2 Cycle 7 Colr ML20217K7741999-09-30030 September 1999 Rev 1 to Vegp,Unit 1 Cycle 9 Colr ML20216E5061999-08-31031 August 1999 Monthly Operating Repts for Aug 1999 for Vegp,Units 1 & 2. with ML20210P9841999-07-31031 July 1999 Monthly Operating Repts for July 1999 for Vogtle Electric Generating Plant,Units 1 & 2.With ML20209H1211999-06-30030 June 1999 Monthly Operating Repts for June 1999 for Vogtle Electric Generating Plant,Units 1 & 2.With ML20196F9711999-05-31031 May 1999 Owner Rept for ISI for Vogtle Electric Generating Plant, Unit 1 Eighth Maint/Refueling Outage ML20195G1731999-05-31031 May 1999 Monthly Operating Repts for May 1999 for VEGP Units 1 & 2. with ML20206N2141999-04-30030 April 1999 Monthly Operating Repts for Apr 1999 for Vogtle Electric Generating Plant,Units 1 & 2.With ML20206A6561999-04-21021 April 1999 Safety Evaluation Authorizing Licensee Re Rev 9 to First 10-year ISI Interval Program Plan & Associated Requests for Relief (RR) 65 from ASME Boiler & Pressure Vessel Code ML18016A9011999-04-12012 April 1999 Part 21 Rept Re Defect in Component of DSRV-16-4,Enterprise DG Sys.Caused by Potential Problem with Connecting Rod Assemblies Built Since 1986,that Have Been Converted to Use Prestressed Fasteners.Affected Rods Should Be Inspected ML20206C2291999-03-31031 March 1999 Revised Monthly Operating Repts for Mar 1999 for Vogtle Electric Generating Plant,Units 1 & 2 ML20205Q8081999-03-31031 March 1999 Monthly Operating Repts for Mar 1999 for Vegp,Units 1 & 2. with ML20205A9581999-03-31031 March 1999 Rev 0 to VEGP Unit 1 Cycle 9 Colr ML20207K6051999-02-28028 February 1999 Monthly Operating Repts for Feb 1999 for Vogtle Electric Generating Plant,Units 1 & 2.With ML20209H3951999-02-15015 February 1999 Rev 2 to ISI Program Second 10-Year Interval Vogtle Electric Generating Plant Units 1 & 2 ML20209H4091999-02-15015 February 1999 Rev 1 to ISI Program Second 10-Year Interval Vogtle Electric Generating Plant Units 1 & 2 ML20202H9851999-01-29029 January 1999 Safety Evaluation Accepting Rev 8 to First 10-year Interval Inservice Insp Program & Associated Requests for Relief for Vogtle Electric Generating Plant,Unit 1 ML20199F8041999-01-13013 January 1999 Corrected Pages to VEGP-2 ISI Summary Rept for Spring 1998 Maint/Refueling Outage ML20199E7561998-12-31031 December 1998 Monthly Operating Repts for Dec 1998 for Vogtle Electric Generating Plant,Units 1 & 2.With ML20198S1781998-12-31031 December 1998 SER Re Second 10-year Interval Inservice Insp Program Plan & Associated Requests for Relief for Southern Nuclear Operating Co,Inc Units 1 & 2 ML20196E5221998-12-0101 December 1998 Rev 8 to ISI-P-014, ISI Program for VEGP-2 ML20198B8571998-11-30030 November 1998 Monthly Operating Repts for Nov 1998 for Vogtle Electric Generating Plant,Units 1 & 2.With ML20195H2131998-10-31031 October 1998 Monthly Operating Repts for Oct 1998 for Vogtle Electric Generating Station,Units 1 & 2.With ML20154L5681998-09-30030 September 1998 Monthly Operating Repts for Sept 1998 for Vegp,Units 1 & 2 ML20151W3681998-08-31031 August 1998 Monthly Operating Repts for Aug 1998 for Vogtle Electric Generating Plant Units 1 & 2.With ML20154L5721998-08-31031 August 1998 Corrected Page from MOR for Aug 1998 for Vegp,Unit 2 ML20237D2051998-07-31031 July 1998 Monthly Operating Repts for July 1998 for Vogtle Electric Generating Plant Units 1 & 2 ML20236V3121998-07-29029 July 1998 Final Part 21 Rept Re Enterprise DSR-4 & DSRV-4 Edgs.Short Term Instability Was Found During post-installation Testing & Setup as Part of Design mod/post-work Testing Process. Different Methods Were Developed to Correct Problem ML20236P6991998-06-30030 June 1998 Monthly Operating Repts for June 1998 for Vogtle Electric Generating Plant,Units 1 & 2 ML20236Q3051998-06-30030 June 1998 Owner'S Rept for ISI for Sixth Maint/Refueling Outage of Vogtle Electric Generating Plant,Unit 2 ML20249A3911998-05-31031 May 1998 Monthly Operating Repts for May 1998 for Vogtle Electric Generating Plant ML20248A1671998-05-22022 May 1998 Interim Part 21 Re Enterprise DSR-4 & DSRV-4 Emergency diesel.Post-installation Testing Revealed,High Em/Rfi Levels Affected New Controllers,Whereas Original Controllers Were unaffected.Follow-up Will Be Provided No Later than 980731 ML20249A3931998-04-30030 April 1998 Revised MOR for Apr 1998 for Vogtle Electric Generating Plant Unit 1 ML20247F3841998-04-30030 April 1998 Monthly Operating Repts for Apr 1998 for Vogtle Electric Generating Plant,Units 1 & 2 ML20154Q9721998-04-20020 April 1998 10CFR50.59(B) Rept of Facility Changes,Tests & Experiments for Vogtle Electric Generating Plant,Units 1 & 2 ML20217H7181998-04-0101 April 1998 Corrected Page 5 to 980324 SER Re Relief Requests Associated W/Second 10-year Interval Insp program.RR-21 in Error in That Component,Suction Damper Inadvertently Omitted. Corrected Page 7 of Technical Ltr Rept Also Encl ML20216D6141998-03-31031 March 1998 Monthly Operating Repts for Mar 1998 for Vogtle Electric Generating Plant,Units 1 & 2 ML20217Q1301998-03-31031 March 1998 Rev 0 to Vepc Unit 2 Cycle 7,COLR ML20217B8831998-03-24024 March 1998 SER Accepting Relief Request RR-5,RR-19,RR-20,RR-21,RR-23 & RR-24 for Second 10-yr Interval ISI Program Plan ML20216E2421998-02-28028 February 1998 Monthly Operating Repts for Feb 1998 for Vogtle Electric Generating Plant,Units 1 & 2 ML20203H9551998-02-23023 February 1998 SER Denying Quality Assurance Program Description Change for Vogtle Electric Generating Plant,Units 1 & 2 ML20203E4831998-02-11011 February 1998 Rev 1 to Vogtle Electric Generating Plant,Units 1 & 2 Second Ten-Yr Interval Pump Inservice Test Program ML20198T1211998-01-31031 January 1998 Owners Rept for Inservice Inspection for Seventh Maintenance/Refueling Outage ML20202G5441998-01-31031 January 1998 Monthly Operating Repts for Jan 1998 for Vogtle Electric Generating Plant,Units 1 & 2 ML20199E5431998-01-31031 January 1998 Rev 3 to WCAP-14720, Vogtle Units 1 & 2 Spent Fuel Rack Criticality Analysis W/Credit for Soluble Boron ML20198L6471997-12-31031 December 1997 Monthly Operating Repts for Dec 1997 for Vogtle Electric Generating Plant,Units 1 & 2 ML20203C2811997-12-0909 December 1997 Safety Evaluation Authorizing Request for Relief of Second 10 Yr Interval Inservice Insp Program ML20202B7881997-12-0101 December 1997 Rev 8 to ISI-P-006, ISI Program for Gpc Vogtle Electric Generating Plant Unit 1 ML20203H0601997-11-30030 November 1997 Monthly Operating Repts for Nov 1997 for Vegp,Units 1 & 2 1999-09-30
[Table view] |
Text
..- . _ - .- -- . . - . - . ~ . . . . .- . . . . . . - . ... -~ - . - . . .
.i e
ENCLOSURE 1=
< V0GTLE ELECTRIC GENERATING PLANT --UNIT 1
' MONTHLY OPERATING REPORT FOR JANUARY 1992 TABLE OF CONTENIS 4
[ NARRATIVE REPORT Page VI-1 -
OPERATING DATA REPORT Page VI-2 AVERAGE DAILY POWER LEVEL Page VI-3 UNIT SHUTDOWNS AND POWER REDUCTIONS Page V1-4 "
d 3
+ 1 l
r i
l' ,
r i
g x
-9202190039 920213 PDR. ADOCK 05000424
, R. PDR
T NARRATIVE REPORT DOCKET NO, 50 -424 UNIT 1 DATE: FEBRUARY 5,1992 COMPLETED BY: G. L HOOPER TELEPHONE: (404) 826 -4104 JANUARY 01 00:00 UNIT 1 AT 100% POWER WITH NO OPERATIONAL PROBLEMS.
JANUARY 31 23:59 UNIT 1 AT 100% POWER WITH NO OPERATIONAL PROBLEMS.
6 V1-1
____ _ --__-J
- - - ~
OPERATING DATA REPORT DOCKET NO. 50-424 DATE: FEBRUARY 5,1992 COMPETED BY: G. L HOOPER TEWPHONE: (404) 826 - 4104 OPERATING STATUS
- 1. UNIT NAME: VEGP UNIT 1
- 2. REPORT PERIOD: JANUARY 1992
- 3. UCENSED THERMAL POWER (MWI): 3411
- 4. NAMEPLATE RATING (GROSS MWe): 1215
- 5. DESIGN ELECTRICAL RATING (NET MWe): 1101
- 6. MAXIMUM DEPENDABLE CAPACITY (GROSS MWe): 1159 *
- 7. MAXIMUM DEPENDABLE CAPACITY (NET MWe): 1105
- 8. IF CHANGES OCCUR IN CAPACITY RATINGS (ITEMS 3 THROUGH 7) SINCE LAST REPORT, GIVE REASONS:
- RATINGS FOR GROSS AND NET MDC WERE CHANGED AS A RESULT OF UNIT PERFORMANCE 11ESTING COMPLETED DURING 1991.
- 9. POWER LEVEL TO WHICH RESTRICTED, IF ANY (NET MWe): NO RESTRlCTIONS
- 10. REASONS FOR RESTRICTION, IF ANY: N/A THIS MONTH YR. TO DATE CUMULATIVE
- 11. HC;dRS IN REPORTING PERIOD: 744 744 40945
- 12. NUMBER OF HOURS REACTOR WAS CRITICAL: 744.0 744.0 34282.9
- 13. REACTOR RESERVE SHUTDOWN HOURS: 0.0 0.0 0.0
- 14. HOURS GENERATOR ON-UNE: 744.0 744.0 33515.0
- 15. UNIT RESERVE SHUTDOWN HOURS: 0.0 0.0 0.0
- 16. GROSS THERMAL ENERGY GENERATED (MWH): 2534684 2534684 111122070
- 17. GROSS ELEC. ENERGY GENERATED (MWH): 873346 873346 37043379
- 18. NET ELEC ENERGY GENERATED (MWH): 836886 836886 35094319
- 19. REACTOR SERVICE FACTOR 100.0 % 100.0 % 84.0 %
- 20. REACTOR AVAILABluTY FACTOR 100.0 % 100.0 % 84.0 %
- 21. UNIT SERVICE FACTOR: 100.0 % 100.0 % 81.9%
- 22. UNIT AVAILABluTY FACTOR: 100.0 % 100.0 % 81.9 %
- 23. UNIT CAPACITY FACTOR (USING MDC NET): 101.8 % 101.8 % 79.0%
- 24. UN!T CAPACITY FACTOR (USING DER NET): 102.2% 102.2% - 77.8 %
- 25. UNIT FORCED OUTAGE RATE: 0.0% 0.0% 7.0%
- 26. SHUTDOWNS SCHEDULED OVERTHE NEXT 6 MOffTHS (TYPE, DATE, AND DURATION OF EACH):
NONE
- 27. IF SHUTDOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF STARTUP: N/A j
l i
V1-2 e
s-rv- - ~
4 UNIT 1 - AVERAGE DAILY - DOCKET NO. 424 FEBRUARY 5,1992 -
POWER LEVEL' DATE:
COMPLETED BY: G. L HOOPER.
TELEPHONE: (404) 826 -4104 i
a j
- DAY. Net MW
)l 1 -1128 * '
a 2 1126
7 1126
- 9 1122 *
-10 1125 *
- 11 1127
14 1122
,- 17 1127
!' R1 1125
, f)3 -1115
- 25 1127
- 28 1125 *-
{ 29 1126 *--
30 1126 *
! 31 1124 *
- MDC CAN BE EXCEEDED UNDER OPTIMAL CONDITIONS'-
1Mh%
V1-3
.. u - , . . . . . . . _ . - _ _ . _ . , - . . . . . , . - _ . , _ . , ...,-- . a
. ~ . . . .. - . . ~ . ~ . . - . . . . . - . - - . - . _ . _ .. . . - . . . . _ -
9 UNIT SHUTDOWNS AND POWER REDUCTIONS DOCKET NO. 50-424 l DATE: FEBRUARY 5,1992 i l
UNIT NAME: VEGP UNIT 1 COMPLEED BY: OcL HOOPER l TELEPHONE: (404) 826 - 4104 1
REPORT MONTH JANUARY 1992 R M S E E Y T A T UCENSEE SC Y S H EVENT TO COMPONENT CAUSE & CORRECTIVE I
P DURATION O O REPORT ED CODE ACTION TO NO. DATE E (HOURS) N D NUMBER ME- (SUBCODE) PREVENT RECURENCE NA NA NA NA NA NA NA NA NA NA F: FORCED REASON: METHOD: EVENTS REPORTED INVOLVE S: SCHEDULED A-EQUIPMENT FAILURE (EXPLAIN) 1 - MANUAL A GREAER THAN 20%
B-MAINTENANCE OR TEST 2 - MANUAL SCRAM REDUCTIONIN AVERAGE C-REFUELING 3 - AUTO. SCRAM DAILY POWER LEVEL FOR D-REGUMTORY RESTRICTION 4 - CONTINUABONS THE PRECEDING 24 HOURS.
E-OPERATOR TRAINING & LICENSE 5 - LOAD REDUCTION i F-ADMINISTRATIVE 9 - OTHER (EXPLAIN)
G-OPERATIONAL ERROR (EXPLAIN)
H-OTHER (EXPMIN) l l
~
V1-4
. -. . ~ . . . - ~. . . - ~ - . - - . - . . . - - . . - . - - .. - . .. - .... - . .-.
l i
i . .
.l .
i i
, ENCLOSURE 2 V0GTLE-ELECTRIC GENERATING > PLANT - UNIT 2 i MONTHLY OPERATING REPORT FOR JANUARY- 1992-TABLE OF CONTENTS i
l-
, NARRATIVE REPORT Page V2 1.
OPEPATING DATA REPORT Page V2-2.
- AVERAGE DAILY POWER LEVEL Page V2-3 UNIT SHUTDOWNS AND POWER REDUCTIONS- Page V2-4 ;
l-4 d
J e
f h
1 i
h 4
A? y - , , ,.~. - , . . m J.y _. , - _ , _ , .._n.~,_ yw. , . . , . . . 4.-. . . - , , _ . . . , , ,,J- ,,%.. - _ _ - mm,..-.. -. .,,r.m. ,,. ,, , ,
. . . _ .- . . . - . - . - . . - . - - . . . . - . . _ . . - - - . . , . - . . . _ . - . - - . . . . . . . . ~ - . - . . ..- -
E NARRATIVE REPORT DOCKET NO. 50 -425 UNIT 2 ..DATE: FEBRUARY 5,1992 -
COMPLETED BY: G. L HOOPER TEGPHONE: _ (404) 826 -4104 L
f JANUARY 01 00:00 UNIT 2 AT 100% POWER WITH NO OPERATIONAL PROBWMS.'
i
- JANUARY 31 23:59 UNIT 2 AT 100% POWER WITH NO OPERATIONAL PROBLEMS.
n_..
1 l-I ,
r F
l i
l l.
1 l
V2-1
" " " ' ' " * * -- " * -+ e.%9 m,_ m_- , ., _ , . , , _ _ _ _
~
OPERATING DATA REPORT DOCKET NO 50-425 DATE: FEBRUARY 5,1992 COMPETED BY; G. L HOOPER -
TELEPHONE: (404) 820 -4104 OPERATING STATUS
- 1. UNIT NAME: VEGP UNIT 2
- 2. REPORT PERIOD: JANUARY 1992
- 3. UCENSED THERMAL POWER (MWt): 3411
- 4. NAMEPLATE RATING (GROSS MWe): 1215
- 5. DESIGN EECTRICAL RATING (NET MWe): 1101
- 6. MAXIMUM DEPENDABE CAPACITY (GROSS MWe): 1163 *
- 7. MAXIMUM DEPENDADLE CAPACITY (NET MWo): 1109 *
- 8. IF CHANGES OCCUR IN CAPACIW RATINGS (ITEMS 3 THROUGH 7) SINCE LAST REPORT, GIVE REASONS:
- RATINGS FOR GROSS AND NET MDC WERE CHANGED AS A RESULT OF UNIT PERFORMANCE TESTING COMPLETED DURING 1991.
- 9. POWER EVEL TO WHICH RESTRICTED, IF ANY (NET MWe): NO RESTRICTIONS
- 10. REASONS FOR RESTRICTION, IF ANY: N/A THIS MONTH YR. TO DATE CUMULATIVE ,
- 11. HOURS IN REPORTIN3 PERIOD: 744 744 23689
- 12. NUMBER OF HOURS REACTOR WAS CRITICAL: 744.0 744.0 21736.4
- 13. REACTOR RESERVE SHUTDOWN HOURS: 0.0 0.0 0.0
- 14. HOURS GENERATOR ON-UNE: 744.0 744.0 21355.4
- 15. UNIT RESERW SHUTDOWN HOURS: 0.0 0.0 0.0
- 16. GROSS THERMAL ENERGY GENERATED (MWH): 2534130 2534130 68993898
- 17. GROSS ELEC ENERGY GENERATED (MWH): 874009 874009 23281160
- 18. NET ELEC. ENERGY GENERATED (MWH): 834639 834639 22134170
- 19. REACTOR SERVICE FACTOR 100.0% 100.0 % 91.8 %
- 20. REACTOR AVAILABluTY FACTOR 100.0% 100.0% 91.8 %
- 21. UNIT SERVICE FACTOR: 100.0 % 100.0 % 90.1 %
100.0% 100.0% 90.1 %
- 22. UNIT AVAILABluTY FACTOR:
101.2% 101.2 % 85.0 %
- 23. UNIT CAPACITY FACTOR (USING MDC NET):
101.9% 101.9 % B4.9%
l
- 24. UNIT CAPACIW FACTOR (USING DER NET):
- 25. UNIT FORCED OUTAGE RATE: 0.0% 0.0% 2.1%
- 26. SHUTDOWNS SCHEDULED OVER THE NEXT 6 MONTHS (TYPE, DATE, AND DURATION OF EACH):
REFUEUNG - MARCH 13,1992 - 57 DAYS
- 27. lF SHUTDOWN AT END OF FEPORT PERIOD. ESTlMATED DATE OF STARTUP: N/A i
l l
l V2-2
.. ~ . . . . . . . - . ~ . - . -. .- - - . -. . - . - - . . . . - .. - . . . - -
4 UNIT 2 AVERAGE DAILY DOCKET NO, 50 - 425 -
. POWER LEVEL DATE: - FEBRUARY 5,1992 COMPLETED BY: G. L HOOPER TELEPHONE: (404) 826 - 4104 ,
f DAY Not MW 1' 1124 *
- 2. 1122
6 1121 * ,
7 1124
11 _ 1125
22 ~ 1124
~24 1122
29 1122
- MDC CAN BE EXCEEDED UNDER OPTIMAL CONDITIONS r-V2-3 yw--- -- - - ,,..-,c , y,m-y. w.c-r+ --we ,S., -.4,,-, ~ w w -~9,+- +1m- -,.m-+ w y
.- - . . . . ~.- . . - - . . . . . . . - . ~ - . - - - - . ~ . .. - . - . ~ . . - . - . . .- . . -
UNIT SHUTDOWNS AND POWER REDUCTIONS DOCKET NO. 50 -425
. DATE:- FEBRUARY 5,1992 UNIT NAME: VEGP UNIT 2 COMPLETEC 3Y: G. L HOOPER TELEPHON' (404) 826 - 4104 ,
NPORT MONTH JANUARY 1992 R M S E E Y '
T A T UCENSEE SC Y S H EVENT TO' COMPONENT CAUSE & CORRECTIVE P DURATION O O REPORT ED ' CODE ACTION TO NO. DATE E (HOURS) N D NUMBER ME (SUBCODE) PREVENT RECURENCE NA NA NA NA NA NA NA NA NA NA F: FORCED REASON: METHOD:- EVENTS REPORTED INVOLVE S: SCHEDULED A-EOUIPMENT FAlLURE (EXPLAIN) 1 - MANUAL A GREATER THAN 20% - .;
B-MAINTENANCE OR TEST 2 - MANUAL SCRAM - REDUCTIONIN AVERAGE -
C-REFUEUNG 3 - AUTO. SCRAM DAILY POWER LEVEL FOR D-REGULATORY RESTRICTION 4 - CONTINUATIONS - THE PRECEDING 24 HOURS.
E-OPERATOR TRAINING & UCENSE 5 - LOAD REDUCTION F-ADMINISTRATIVE 9 - OTHER (EXPLAIN)
G-OPERATIONAL ERROR (EXPLAIN)
H-OTHER (EXPLAIN)
.V2-4
A .- q -A h
9 9
ENCLOSURE 3 V0GTLE ELECTRIC GENERATING PLANT - UNITS 1 AND 2 MONTHLY OPERATING REPORT FOR JANUARY 1992 CHALLENGES TO PORY OR SAFETY VALVES l
)
--. - - - ... - .. . . . . . - . - . . . . . . . . . . - .- . - . - - . . _ . . .... - . - ~..- ...- ... - -
.?
f i 4 -?
(ENCLOSURE 3) l DOCKET NOS. 50 - 424,60-425-1' VEGP UNITS 1 & 2
- DATE: FEBRUARY 5,1992 COMPWTED BY: G. L HOOPER '
l- TEEPHONE: (404) 826 -4104 1
EVENT DATE TAG NO.- -TYPE . DESCRIPTION THERE WERE NO CHALLENGES TO PORV OR SAFETY VALVES, i