ML20136G347
| ML20136G347 | |
| Person / Time | |
|---|---|
| Site: | Vogtle |
| Issue date: | 02/28/1997 |
| From: | Hooper G, Mccoy C GEORGIA POWER CO. |
| To: | NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM) |
| References | |
| LCV-0965-B, LCV-965-B, NUDOCS 9703180012 | |
| Download: ML20136G347 (12) | |
Text
.
_. ~ _. _ _.
.. - - ~..._ _.. _.
. Georgia Porttr Company 40 inytmess Center Parkway Post Office Box 1295 Birmingham, Alabama 35201
, Telephone 205 992 7122 Georgia Power
~
ic P esdent. Nuclear Vogtie Project March 11, 1997 LCV-0965-B Docket Nos. 50-424 50-425 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk l
Washington, D. C. 20555 Gentlemen:
VOGTLE ELECTRIC GENERATING PLANT hf0NTHLY OPERATING REPORT Enclosed are the February 1997, monthly operating reports for Vogtle Electric Generating Plant (VEGP) Units 1 and 2. These reports are submitted in accordance with the Improved Technical Specification 5.6.4.
Sincerely, h$
l C. K. McCoy CKM/JLL Enclosures cc:
Georgia Power Company Mr. J. B. Beasley, Jr.
Mr. M. Sheibani
')k '
NORMS l-U. S. Nuclear Regulatory Commission l
Mr. L. A. Reyes, Regional Administrator Mr. L. L. Wheeler, Licensing Project Manager, NRR Mr. C. R. Ogle, Senior Resident Inspector, Vogtle 9703180012 970228 PDR ADOCK 05000424 R
PDR 180017 115.R555555558
i I
ENCLOSURE 1 VOGTLE ELECTRIC GENERATING PLANT - UNIT 1 MONTHLY OPERATING REPORT FOR FEBRUARY 1997 TA.BLE OF CONTENTS NARRATIVE REPORT Page VI-l OPERATING DATA REPORT Page VI-2 AVERAGE DAILY POWER LEVEL Page VI-3 UNIT SHUTDOWNS AND POWER REDUCTIONS Page VI-4 i
..._..m._..._.--_
l NARRATIVE REPORT DOCKET NO. 50-424 UNIT 1 DATE:
March 3,1997 l
COMPLETED BY: G. L. Hooper -
TELEPHONE:
(706) 826-4104 I
February 01 00:00 Unit at 100% power with no operating problems.
February 28 23:59 Unit at 100% power with no operating problems.
r l
b l
f t
b i
i
'}
1 a
i V11 i
i I
m i
l OPERATING DATA REPORT DOCKET NO. 50-424 DATE: Max.h 3,1997 COMPLETED BY: G. L. Hooper TELEPHONE:
(706)826-4104 OPERATING STATUS
- 1. UNIT NAME:
VEGP UNIT 1
- 2. REPORT PERIOD:
Feb-97
- 3. LICENSED THERMAL POWER (MWt):
3565
- 4. NAMEPLATE RATING (GROSS MWe):
1215
- 5. DESIGN ELECTRICAL RATING (NET MWe):
1169
- 6. MAXIMUM DEPENDABLE CAPACITY (GROSS MWe):
1216
- 7. MAXIMUM DEPENDABLE CAPACITY (NET MWe):
1162 l
- 8. IF CHANGES OCCUR IN CAPACITY RATINGS (ITEMS 3 THROUGH 7) SINCE LAST REPORT, GIVE REASONS:
NA
- 9. POWER LEVEL TO WHICH RESTRICTED, IF ANY (NET MWe):
NO RESTRICTIONS
- 10. REASONS FOR RESTRICTION, IF ANY:
NA THIS MONTH YR. TO D/(TE CUMULATIVE
- 11. HOURS IN REPORTING PERIOD:
672 1416 85465 l
- 12. NUMBER OF HOURS REACTOR WAS CRITICAL:
672.0 1416.0 75130.8 l-
- 13. REACTOR RESERVE SHUTDOWN HOURS:
0.0
. 0.0 0.0
[
.14. HOURS GENERATOR ON-LINE:
672.0 1410.0 73921.5 l
- 15. UNIT RESERVE SHUTDOWN HOURS:
0.0 0.0 0.0
- 16. GROSS THERMAL ENERGY GENERATED (MWH):
2393961 5042459 251466767 l
- 17. GROSS ELEC. ENERGY GENERATED (MWH):
828985 1748805 84973930
- 18. NET ELEC. ENERGY GENERATED (MWH):
793425 1674105 80866310
- 19. REACTOR SERVICE FACTOR 100.0 %
100.0 %
87.9 %
- 20. REACTOR AVAILABILITY FACTOR 100.0 %
100.0 %
87.9 %
- 21. UNIT SERVICE FACTOR:
100.0 %
100.0 %
86.5 %
- 22. UNIT AVAILABILITY FACTOR:
100.0 %
100.0 %
86.5 %
- 23. UNIT CAPACITY FACTOR (USING MDC NET):
101.6%
101.7 %
84.6 %
l
- 24. UNIT CAPACITY FACTOR (USING DER NET):
101.0 %
101.1 %
84.0 %
i
- 25. UNIT FORCED OUTAGE RATE:
0.0%
0.0%
4.4%
- 26. SHUTDOWNS SCHEDULED OVER THE NEXT 6 MONTHS (TYPE, DATE, AND DURATION OF EACH):
Maintenance, March 28,9 days
- 27. IF SHUTDOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF STARTUP:
NA l
l V1-2 1
J
l I
t UNIT 1 AVERAGE DAILY DOCKET NO. 50-424 POWER LEVEL DATE:
March 3,1997 COMPLETED BY: G. L. Hooper TELEPHONE:
(706) 826-4104 i
DAY Net MW 1.........
1182
- 2.......
1180
- 3.............
1177
- 4...
1178
- 5..
1179
- I 6...-........,
1186
- 7............
1185
- 8..........
1183
- 9:
1186
- 10.....
1187 *
- 11...
1187
- 12..
1187
- 13....
1185
- l 14.......
1186
- 1 5.............
1184
- 16....
1185
- 17...
1183
- 18:
1182
- 19.............
1178
- 20......
1176
- 21....
1169
- 22.
1175
- 2 3.............
1185
- 24..............
1185
- 2 5.............
1183
- i 26...............
1174
- l 27.......
1166
- 28..
1166
- 1 i
l t
i 4 '
?
k i'
V1-3
UNIT SHUTDOWNS AND POWER REDUCTIONS DOCKET NO. 50-424 DATE: March 3,1997 l
UNIT NAME:
VEGP UNIT 1 COMPLETED BY: G. L. Hooper TELEPHONE:
(706)820-4104 REPORT MONTH Feb-97 R
M S
E E
Y T
A T
LICENSEE SC Y
S H
EVENT TO COMPONENT CAUSE & CORRECTIVE P
DURATION O
O REPORT ED CODE ACTION TO NO.
DATE E
(HOURS)
N D
NUMBER ME (SUBCODE)
PREVENT RECURRENCE NA NA NA NA NA NA NA NA NA NA F: FORCED REASON:
METHOD:
EVENTS REPORTED INVOLVE S: SCHEDULED A-EQUIPMENT FAILURE (EXPLAIN) 1-MANUAL A GREATER THAN 20%
B-MAINTENANCE OR TEST 2-MANUAL SCRAM REDUCTION IN AVERAGE C-REFUELING 3-AUTO. SCRAM DAILY POWER LEVEL FOR D-REGULATORY RESTRICTION 4-CONTINUATIONS THE PRECEDING 24 HOURS.
E-OPERATOR TRAINING & LICENSE 5-LOAD REDUCTION F-ADMINISTRATIVE 9-OTHER (EXPLAIN)
G-OPERATIONAL ERROR (EXPLAIN)
H-OTHER (EXPLAIN) e
\\
V14
ENCLOSURE 2 VOGTLE ELECTRIC GENERATING PLANT - UNIT 2 MONTHLY OPERATING REPORT FOR FEBRUARY 1997 TABLE OF CONTENTS NARRATIVE REPORT Page V2-1 OPERATING DATA REPORT Page V2-2 AVERAGE DAILY POWER LEVEL Page V2-3 UNIT SHUTDOWNS AND POWER REDUCTIONS Page V2-4
f f
3 i
f NARRATIVE REPORT DOCKET NO. 50-425 UNIT 2 DATE:
March 3,1997 COMPLETED BY: G. L. Hooper TELEPHONE:
(706)826-4104
)
Fibruary 01 00:00 Unit at 100% power with no operating problems.
February 28 23:59 Unit at 100% power with no operating problems.
5 a
1 4
k i
i Y
i e
^
f 4
i l
l t
i 4
a i
)'i r
V2-1
4 OPERATING DATA REPORT DOCKET NO. 50-425 DATE: March 3.1997 COMPLETED BY; G. L. Hooper TELEPHONE:
(706) 826-4104 I
OPERATING STATUS
- 1. UNIT NAME:
VEGP UNIT 2
- 2. REPORT PERIOD:
Feb-97
- 3. LICENSED THERMAL POWER (MWt):
3565 4, NAMEPLATE RATING (GROSS MWe):
1215
)
- 5. DESIGN ELECTRICAL RATING (NET MWe):
1169
- 6. MAXIMUM DEPENDABLE CAPACITY (GROSS MWe):
1216
- 7. MAXIMUM DEPENDABLE CAPACITY (NET MWe):
1162
- 8. IF CHANGES OCCUR IN CAPACITY RATINGS
_ (ITEMS 3 THROUGH 7) SINCE LAST REPORT, GIVE REASONS:
NA
- 9. POWER LEVEL TO WHICH RESTRICTED, IF ANY (NET MWe):
NO RESTRICTIONS
- 10. REASONS FOR RESTRICTION, IF ANY:
NA THIS MONTH YR. TO DATE CUMULATIVE
- 11. HOURS IN REPORTING PERIOD:
672 1416 68209 I
12 NUMBER OF HOURS REACTOR WAS CRITICAL:
672.0 1416.0 61479.8
- 13. REACTOR RESERVE SHUTDOWN HOURS:
0.0 0.0 0.0
- 14. HOURS GENERATOR ON-LINE:
672.0 1416.0 60815.2
- 15. UNIT RESERVE SHUTDOWN HOURS:
0.0 0.0 0.0
- 16. GROSS THERMAL ENERGY GENERATED (MWH):
2393844 5044545 206013588
- 17. GROSS ELEC. ENERGY GENERATED (MWH):
831226 1755009 70243707
- 18. NET ELEC. ENERGY GENERATED (MWH):
797416 1683449 66959347 19, REACTOR SERVICE FACTOR 100.0 %
100.0 %
90.1 %
- 20. REACTOR AVAILABILITY FACTOR 100.0 %
100.0 %
90.1 %
- 21. UNIT SERVICE FACTOR:
100.0 %
100.0 %
89.2% -
- 22. UNIT AVAILABILITY FACTOR:
100.0 %
100.0 %
89.2 %
23, UNIT CAPACITY FACTOR (USING MDC NET):
102.1 %
102.3 %.
86.7%
- 24. UNIT CAPACITY FACTOR (USING DER NET):
101.5 %
101.7 %
86.6 %
- 25. UNIT FORCED OUTAGE RATE:
0.0%
0.0%
1.7%
- 26. SHUTDOWNS SCHEDULED OVER THE NEXT 6 MONTHS (T/PE, DATE. AND DURATION OF EACH):
None
- 27. IF SHUTDOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF STARTUP: NA i
V2-2
UNIT 2 AVERAGE DAILY DOCKET NO. 50-425 POWER LEVEL DATE:
March 3,1997 COMPLETED BY: G. L. Hooper TELEPHONE:
(706) 826-4104 DAY Net MW 1....
1190
- 2.
1186
- 3...
1185
- 4.
1187
- 5.
1185
- 6.
1193
- 7.
1194
- 8..
1191
- 9.
1195
- 10'.
1195 *
- 11..
1195
- 12..
1195 *-
13.
1194
- 14.
1194
- 15, 1191
- 16.
1192
- 17.
1191
- 18.
1189
- 19.
1185
- 20..
1181
- 21..
1176
- 22..
1180
- 23.
1189
- 24..
1185
- 25.
1184
- 26..
1178
- 27..
1164
- 28...
1163 *
. _. ~
. ~
.. ~...
e UNIT SHUTDOWNS AND POWER REDUCTIONS DOCKET NO. 50-425 DATE: March 3,1997 j
l UNIT NAME:
VEGP UNIT 2 COMPLETED BY: G. L. Hooper -
i TELEPHONE:
(706)826 4104 j
j REPORT MONTH
. Feb-97 1
lR 1
M S
1 E
E Y
l T
A T
LICENSEE SC
]
Y S
H EVENT TO COMPONENT CAUSE & CORRECTIVE P
DURATION O
O REPORT ED CODE ACTION TO NO.
DATE E
(HOURS)
N D
NUMBER ME (SUBCODE)
PREVENT RECURRENCE NA NA-NA NA NA NA NA NA NA NA F: FORCED REASON:
METHOD:
EVENTS REPORTED INVOLVE S: SCHEDULED A-EQUIPMENT FAILURE (EXPLAIN) 1-MANUAL A GREATER THAN 20%
B-MAINTENANCE OR TEST 2-MANUAL SCRAM REDUCTION IN AVERAGE C-REFUELING 3-AUTO. SCRAM DAILY POWER LEVEL FOR D-REGULATORY RESTRICTION 4-CONTINUATIONS THE PRECEDING 24 HOURS.
E-OPERATOR TRAINING & LICENSE 5-LOAD REDUCTION F-ADMINISTRATIVE 9-OTHER (EXPLAIN)
G-OPERATIONAL ERROR (EXPLAIN)
H-OTHER (EXPLAIN) i i
.. ~..
l e.
g 4
1
. ENCLOSURE 3
]
YOGTLE ELELTRIC GENERATING PLANT-UNITS 1 AND 2 -
CHALLENGES TO PORY OR SAFETY VALVES
':I i
i DOCKET NOS. 50-424,50-425 DATE:
March 3,1997
' COMPLETED BY: G. L. HOOPER TELEPHONE:
(706)826-4104 1
EVENT.
'DATE TAG NO.
TYPE DESCRIPTION NA NA NA NA i
1 1