ML20041C272

From kanterella
Jump to navigation Jump to search
Forwards LER 82-003/03L-0.Detailed Event Analysis Encl
ML20041C272
Person / Time
Site: Fort Saint Vrain Xcel Energy icon.png
Issue date: 02/19/1982
From: Warembourg D
PUBLIC SERVICE CO. OF COLORADO
To: Jay Collins
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
Shared Package
ML20041C273 List:
References
P-82046, NUDOCS 8203010025
Download: ML20041C272 (4)


Text

._. - . _ -

4 public Service Company Cf Odbrado

^

Road 19 1/2, Platteville, Colorado 80651-9298

  • Q

'(9 t

.; [ ggcSWED

~ 42 February 19, 1982 7 FEB 2 61982" Fort St. vrain -

umaracy y" ;I Unit No. 1 W$ P-82046 g @hhSy,}lQ(N-o

  • D m

re2282"d Mr. John T. Collinr, Regional Administrator Region IV Nuclear Regulatory Commission 611 Ryan Plaza Drive Suite 1000 Arlington, Texas 76011

Reference:

Facility Operating License No. DPR-34 i Docket No. 50-267 J

Dear Mr. Collins:

Enclosed please find a copy of Reportable Occurrence Report No. 50-267/82-003, Final, submitted per the requirements of Technical Specification AC 7.5.2(b)1 and AC 7.5.2(b)2.

Also, please find enclosed one copy of the Licensee Event Report for Reportable Occurrence Report No. 50-267/82-003. -

Very truly yours, I

w /Nt 4 l Don Warembourg l Manager, Nuclear Production 1

DW/cis Enclosure cc: Director, MIPC -

? $l >

l l

l 8203010025 820219

PDR ADOCK 05000267 S PDR

l REPORT DATE: February 19, 1982 REPORTABLE OCCURRENCE 32-003 ISSUE O OCCURRENCE DATE: January 22, 1982 Page 1 of 3' FORT ST. VRAIN NUCLEAR GENERATING STATION s PUBLIC SERVICE COMPANY OF COLORADO 16805 WELD COUNTY ROAD 19 1/2 PLATTEVILLE, COLORADO 80651-9298 REPORT NO. 50-26//82-003/03-L-0 Final IDENTIFICATION OF OCCURRENCE:

Ouring the annual calibration of the circulator drain pressure instrumentation, it was discovered that one of the three circulator drain malfunction pressure differential switches for 1C circulator was out of calibration and could have allowed operation with a trip setpoint less conservative than required by LCO 4.4.1, Table 4.4.3.

This is reportable per Fort St. Vrain Technical Specification AC 7.5.2(b)1 and AC 7.5.2(b)2.

EVENT DESCRIPTION:

With the reactor shutdown and depressurized for scheduled maintenance, instrument personnel performing the annual calibration of the helium circulator steam / water drain indicators found one of three channels for 1C circulator out of tolerance in the non-conservative direction. PDIS-21322 for 1C circulator was found to trip at 2.0 psid, below the limit of 5 psid specified in LCO 4.4.1, Table 4.4.3. Since it cannot be established when this channel became inoperable, operation in a degraded mode of LCO 4.4.1 must be assumed.

The switch setting which was found to be less conservative than that established in the Technical Specifications would not have prevented the fulfillment of the functional requirements of the system.

CAUSE DESCRIPTION: .

~

The cause of the pressure differential indicating switch being out of calibration was found to be dirty contacts which prevented the switch from functioning accurately within the calibration range.

REPORTABLE OCCURRENCE 82-003 ISSUE O Page 2 of 3 CORRECTIVE ACTION:

The faulty contacts were cleaned, and the switch calibrated to the required setpoint. The surveillance was completed satisfactorily.

No further corrective action is anticipated or required.

REPORTABLE OCCURRENCE 82-003 ISSUE 0 Page 3 of 3 Prepared By: d M- /

Robert A. Dickerson Technical Services Technicisn Reviewed By: A#I CharTes FuileF

//

Technical Service Engi_eer g Supervisor

/

/

Reviewed By: f/

Edwin D7 fiiI), ""

Station Manager Approved By: t-- WAv.wM Don Warembourg Manager, Nuclear Production

/