ML20055H657

From kanterella
Jump to navigation Jump to search
Responds to NRC Bulletin 90-001, Loss of Fill Oil in Transmitters Mfg by Rosemount. No Rosemount Model 1153 or 1154 Transmitters Presently in Use at Plant
ML20055H657
Person / Time
Site: Fort Saint Vrain Xcel Energy icon.png
Issue date: 07/20/1990
From: Crawford A
PUBLIC SERVICE CO. OF COLORADO
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
REF-PT21-90 IEB-90-001, IEB-90-1, P-90233, NUDOCS 9007270130
Download: ML20055H657 (5)


Text

,

l h Public Service'  :::::. h.

P.O. Box 840 l'

Denver CO 80201-o640 j

~ July 20', 1990 i Fort St. Vrain A. Clegg Crawford -

Unit No. 1 Ec'd/$",",'uon,  !

P-90233 l

l U..S. Nuclear Regulatory Coninission  !

U ATTN: Document Control Desk i

Washington, D.C. 20555 i Docket No. 50-267  ;

SUBJECT:

PSC Response to NRC Bulletin No. 90-01 " Loss of F111-011 ,

in Transmitters Manufactured by Rosemount" REER!!NCE: NRC Bulletin No. 90-01 Dated March 9,1990 (G-90039)  !

Dear Sirs:

Public ' Service Company of Colorado (PSC) has reviewed NRC dulletin  !

90-01' " Loss of Fill-Oil on transmitters manufactured by Rosemount" ,

4 referenced above for its applicability to the fort St. Vrain Nuclear Generating Station. The following response is provided:

+ ,

NRC REQUESTED ACTIONS Requested Action 1:

Identify Model_1153 Series B, 1153 Series 0, and Model 1154 pressure -

or differential pressure transmitters, excluding Model 1153 Series B, 1153 Series D, and Model 1154 transmitters manufactured by Rosemount subsequent to July 11, 1989, that are currently utilized in either safety-related systems or systems installed in accordance with 10 CFR 50.62 (the ATWS rule).  :

PSC Response:

A review of Fort St. Vrain instrumentation established that there are no Rosemount Model 1153 or 1154 transmitters in use of any vintage.

Paquested Actions 2 through 5: .

The remaining requested actions are based upon transmitters identified by Requested Action 1 as being in use. Since there are no Rosemount ~Model 1153. or 1154 transmitters of any vintage in use at '

Fort St. Vrain, no further responses are necessary.

9007270130 900720 ADOCK 05000267 PDR g FDC g

'/i

.P-90233 p ,pa e o Ju y 20, 1990 l

NRC REPORTING REQUIREMENTS ~

, _ Reporting Requirements '1:

i provide, within 120_ days af ter receipt of .this bulletin, a response l L -that:

a)  : Confirms that Items 1, 2 3, 4, and 5 of Requested Actions i for Operating Reactors have been completed.

b)- Identifies the indicated manufacturer, the model number, the  ;

system the transmitter was utilized _in, the approximate l amount- of time at .

and the disposition (pressure, e.g., returnedthetocorrective vendor foractions taken, analysis)- l of _Rosemount Model 1153 Series B. Model 1153 Series D, and -  :

Model 1154 transmitters that are believed to have exhibited: '

f symptoms indicative. of- loss of fill-oil or have been

confirmed to have experienced a loss of fill-oil. This ,

, should include Model 1153 Series B. Model 1153 Series 0 and Model 1154 transmitters manufactured after July 11, 1989, i

c) Identifies the system in which the Model 1153 Series B,1153 i Series D, and Model 1154 transmitters from the manufacturing  !

lots that ha';e been identified by Rosemount as having a high-failure fraction due to loss of-fill-oil are . utilized and  :

provides a schedule for replacement of-these transmitters <

which are in use in'the reactor protection or engineered safety features actuation systems, pSC Responsel ,

la) ~ Items 1, 2, 3, 4, and 5 of Requested Actions for Operating' .

' Reactors have been completed.

Ib)L No Rosemount Model 1153 or 1154 transmitters of any vintage are in use at fort St. Vrain. .

Ic).No Rosemount Model 1153 or 1154 transmitters of any' vintage ,

are in use at Fort St. Vrain. 1 t

b 1

i

g .- - .

'P-90233- -

+

M , , Rage 3 July '20, 1990 '

I -Reporting Requirement 2:

Model .1153 Series B, Model 1153 Series D,- and Model 1154, transmitters L that, subsequent.to providing the: response required by Item 1 above, '

exhibit symptoms of loss of fill-oil or are confirmed to have

!; experienced a loss of fill-oil should be reviewed forf reportability

  • under : existing NRC regulations. If determined not to be reportable. l L addressees are requested to document and maintain, in accordance with  ;

existing plant procedures, information consistent with that requested  !

7

. in Item 1 b) above for each transmitter identified.

PSC Response: i I Thisi reporting requirement is based upon transmitters identified by ,

Reporting Requirement I as being in use. Since there :are' no L

Rosemount Model 1153 or 1154 transmitters of any vintage in use at Fort St. Vrain, no further. response is necessary. ,

ROSEMOUNT MODEL 1151 and 1152 TRANSMITTERS a

During the search of the Fort St. Vrain instrumentation, 24 Rosemount Model 1151 and 1152 transmitters were identified as being in use.

O These Model .1151 and 1152 transmitters are .in safety-related applications which are required to maintain a pressure boundary only.-

l The encouraged actions identified in the Bulletin do not apply to the

.Rosemount Model 1151 and 1152 transmitters that are installed in l '

safety-related for pressure boundary only applications per the '

clarification by Nuclear Management and Resources Council (NUMARC)

+

letter dated June 13, 1990.

Since the above transmitters are safety-related for pressure bo.ndary only, and because the manufacturer has-not been able to conclusively a identify a deficiency with these particular models (Models 1151 and ,

1152), it does not-appear warranted to pursue' the matter further. If '

~in the future, Rosemount, NUMARC, or the NRC definitely determine the existence of a problem with these models, we will re-evaluate the relative issues.

Very truly yours.

  • f A.6 Clegg

$,1) Craw' ford /

Vice President Nuclear Operations ,

ACC/AB:pa p

h t

t

m

,4

=e '-u' y n. .

< o

, 1 s i 's , I!?

N'I [m[ f.I j ' -, a [, ' I' C. ',

, i 7p ~ ; '+ p.90233 '. ' + + ,

  • 4'z , y u. #;^ *
tid NJ. 3g 9 Wy;20.11990 ,

. ;hJu *

{

I 1 M:. , ,

xc: . Regional Administrator, Region IV

- s ATTN:, Mr.-J.'B. Baird-.

- Technica1' Assistant:-

b Division 'of, Reactor Projects

< v

' Mr.' Robert.Farrell:

p. Senior Resident Inspector.

tFort St. Vrain-

'.k[

..i .

g ,i

!! w. J:. 0,y ?, - i, c.

a y

l::

p'

+

. .n ,,

+

f f i; i

r m-I,.-'

9 ll ' f '

m ,

s

[ .h '

a

! 4 f .} -

c ,

g.-

I .\

^',Q, ,

d i i  !'

i t

'* r -

e I

n k }. 2g'

. +i r, , , ,

s h

.4

'-.\.

  • i r

1

) >

\ >

Y c i e.

.g 1 ,

1 pe, 3 l' i p

,l'

?

i 3 , .!

, 3r -

c i

4

.}j )'

j  ;

-1

_p'- ,

  1. g n... ,-

E F- ) w ske~

,[..', ,.s_,,,,,,y...  ; ...%, , ,,, _ j, , ._ , , , , _ , _ _

{

'O +

UNITED STATES OF AMERICA

). NUCLEAR REGULATORY COMMISSION In the Matter of NRC Bulletin 90-01 )

)

Public Service Company of Colorado ) Docket No. 50-267 i Fort St. Vrain Unit No. 1 ) [

q, AFFIDAVIT A. Clegg Crawford being first duly sworn, deposes and says: That he is Vice President, Nuclear Operations.,of Public Service Company ,

of Colorado, the Licensee herein, that he has read the informatien presented in the attached letter and knows the contents thereof, ano that the statements and matters set forth therein are true and .

correct to the best of his knowledge, information and belief. "

i t

d' Ml A. Clegg'CrawfM d Vice President Nuclear Operations i

STATE OF '[6/ AMMO )

COUNTY.OF b/[ )

?

Subs:ri e and sworn to before me, a Notary Public on this 20 day of dr1

,199g j k WlM o Y }$$nas, Notary Pubiic v My commission expires N W/ &2(4,19kE

.