ML19354D744

From kanterella
Jump to navigation Jump to search
Requests Relief from Requirements of Generic Ltr 89-10 Re motor-operated Valves Since Plant Permanently Shut Down Since 890818 & Defueling Initiated on 891127
ML19354D744
Person / Time
Site: Fort Saint Vrain 
Issue date: 12/08/1989
From: Crawford A
PUBLIC SERVICE CO. OF COLORADO
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
GL-89-10, P-89464, NUDOCS 9001020245
Download: ML19354D744 (6)


Text

o y

0 Public Service' u"a*l A r.

P.O. Box 840 Denver CO 80201- 0840 A. Clegg Crawford Vice President 4

December 8, 1989 Nuckw Opemies l

[

Fort St. Vrain Unit No. 1 P-89464 U. S. Nuclear Regulatory Commission Document Control Desk Washington, D. C. 20555 Docket No. 50-267

SUBJECT:

Generic Letter 89-10 Motor-operated Valves

REFERENCES:

See Attachment Gentlemen:

In accordance with the intent of Generic Letter 89-10 (Reference 1)

Public Service Company of Colorado (PSC) has performed an engineering t

evaluation (EE 89-0005) of all motor-operated valves at Fort St.

Vrain.

The conclusion of this evaluation is that no motor operators are relied upon to prevent or mitigate the consequences of design-basis accidents during defueling.

All valves cre accessible for manual operation or-repositioning at all times. A minimum of five days is available to complete valve alignments in order to avoid d.amage to the plant in the event of an accident.

Therefore, PSC requests relief from the requirements of Generic Letter 89c10 (Reference 1).

The status of the Fort St. Vrain reactor is different frorn the status that existed at the time of responses to Bulletin 85-03 (References 2, 3, 4, 5, 6, 7 and 8).

The Fort St.

Vrain reactor has been permanently shut down as of August 18, 1989 (Reference 9) and defueling was started on November 27, 1989.

The Fort St. Vrain reactor will not go critical again.

The reactor has beet, cooled for over three months since the permanent shutdown.

It has fanched a condition where no permanent damage would i

result for at letst five days after a loss of all cooling, including liner coolings as presented in "The Safety Analysis Report For Reacte Defueling" Section 5.2.7 (Reference 10).

b 9001020245 891209 PDR-ADOCK 05000267 P

PNV j

=

,L t

j P-89464 Decemter 8,-1989 L

[

Bulletin 89-10 requires licensees to perform two tasks:

1)

Complete design-basis reviews, any required " prototype" testing, and have a program in place within 5 years or 3 refuelings(whicheverislater).

2)

Have a program description and schedule for all the i

requested actions available within one year or one refueling outage, (whichever is_ later),

o Fort St.

Vrain, being a permanently shutdown plant, has no more refuelings planned.

Fuel is being removed permanently from the reactor as of November 27, 1989, it is expected that the reactor l

will be completely defueled well within the five years permitted for establishing an enhanced motor operated valve performance improvement program as: required by Generic Letter 89-10.

The minimum of five days to take corrective action after a loss of all cooiing allows adequate time to operate critical valves manually, if necessary. Therefore, PSC believes that no additional measures to improve motor-operated valve performance at Fort St.

Vrain are necessary.

The secondary cooling fluid being used at Fort St.

Vrain is condensate at a maximum pressure of 300 psig and maximum temperature of 120- degrees F.

Any pipe rupture that would release this cooling s

fluid could be isolated by remote operation of the motor-operated valves, by manual operation of the valves, or by turning off the operating condensate pump (5) without adverse consequences to safety at Fort St. Vrain.

4 As a result of the conclusions of the engineering evaluation (EE 89-0005) for motor-operated valves, the status of the fort St.

Vrair

reactor, the length of time available to take corrective action for any loss of cooling or pipe rupture, and the forecast that the Fort St.

Vrain reactor will be defueled before the additional design J

reviews and corrective actions of Generic Letter 89-10 are required P

to be complete, PSC requests relief from the requirements of Generic Letter 89-10 for the Fort St. Vrain reactor.

The results of the engineering evaluation EE 89-0005 are on file at Fort St. Vrain and may be examined upon request.

PSC requests NRC concurrence that no additional measures to improve motor-operated valve performance are required for Fort St.

Vrain.

As such, PSC plans to submit no further reports on this issue, i

s mk

['. f>

'[jj i v

s.

Y 4,

P-89464-December 8, 1989 If> you' have any questions concerning this matter, please. contact Mr.

M.:H.-Holmes at (303) 480-6960.

Sincerelyi g, &y A. Clegg Crawford, Vice President Nuclear Operations ACC/JMW/km-

- Attachment ec: Regional Administrator, Region IV, ATTN:. MR. T.:F. Westerman, Chief Projects.Section B Mr.-Robert Farrell

' Senior Resident Inspector

. Fort St.~Vrain-1

e r.

i UNITED STATES OF AP. ERICA NUCLEAR REGULATORY COMMISSION In the Matter

)

)

Public Service Company of Colorado

)

Docket No 50-267 Fort St. Vrain Unit No. 1

)

AFFIDAVIT A.

Clegg Crawford being first duly sworn, deposes and says: That he is Vice President, Nuclear Operations, of Public Service Company of Colorado, the Licensee herein, that he has read the information presented in the attached letter and knows the contents thereof, and that the statements and matters set forth therein are true and correct to the best of his knowledge, information and belief, A

A Clegg Crawford "

Vice President Nuclear Operations STATE OF COLORADO

)

)

COUNTY OF DENVER

)

Subscribe and sworn to before me, a Notary Public on this 9d day of December

, 1989, 0$M &

Y c

Notary Public o

My commission expires January 6

, 1993,

li:7 it.

ATTACHMENT 1 S'

@?

TO P-89464 REFERENCES

}-

e awaunun

3 b

l

!i. -

~

m 1

c i

fJ l

e%

,~

o 1

j REFERENCES

'i l.

L

.1, Generic letter No. 8910 dated June 28,1989(G-89227) i 2.

PSC Letter, Walker to Gagliardo, dated May 14,1986,(P-86356) i u

3;. PSC ' Letter, Walker.- to-Gagliardo, dated September 5,_1986, (P-

.l 86538)-

'. (

4.

PSC-Letter, Williams to Document Control Desk', dated September-

[

.16,'1987,(P-87295)-

O; 5.

PSC Letter,' Williams to Document Control Desk, dated October 15, 1987,(P-87353).

'6.. PSC Letter, Williams to Document Control Desk, dated January 14, E

1988,-(P-88001):

1 i

7.

PSC-.: Letter, -Williams to Document Control' Desk, dated July 15, 1988,(P-88250) 8..

PSC Letter,' Williams to Document Control Desk, dated May 8, 1989,.

j (P-89166) t 3

9.

PSC Letter, Crawford to Weiss, dated November 21 1989, (P-89452)-

~t

10. PSC Letter, Crawford to Weiss, Dated August 16,1989,(P-89287) l-e

.?

I

[

5 y

i j

.