ML17285A143

From kanterella
Jump to navigation Jump to search
Forwards Rev 1 to Insp of Anf Fuel Assemblies 1163 & 1164 After One-Cycle of Irradiation at Washington Nuclear Plant 2 Reactor. Insps Motivated in Part by Util Concerns Re Crud Induced Localized Corrosion.Rept Withheld (Ref 10CFR2.790)
ML17285A143
Person / Time
Site: Columbia Energy Northwest icon.png
Issue date: 12/08/1988
From: Sorensen G
WASHINGTON PUBLIC POWER SUPPLY SYSTEM
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
Shared Package
ML17285A144 List:
References
GO2-88-262, NUDOCS 8812220353
Download: ML17285A143 (6)


Text

~t s AC CKXZRA.TED Ql BUTI ON DEMON TION SYSTEM REGU~ INFORMATION DISTRIBU STEM (RIDS)

ACGSSSZON7NBR:8812220353 DOC.DATE: 88/12/08 NOTARZZED: YES DOCKET I FACZL:50-397 WPPSS Nuclear Project, Unit 2, Washington Public Powe 05000397

-AUTH. NAME 'AUTHOR AFFILIATION SORENSEN,G.C.. Washington Public Power Supply System RECIP.NAME RECIPIENT AFFILIATION Document Control Branc (Document Co o Desk

SUBJECT:

Forwards Rev 1 to "Insp of ANF Fue s e 'es Q~~

'1163 6 1164 s a~/8g After One Cycle of Irradiation at WNP-2 Reactor,May 1987."

DZSTRZBUTZON CODE: AP01D COPZES RECEZVED:LTR J ENCL J SZZE: 5 4 8'0 TITLE: Proprietary Review Distribution Operating Reactor NOTES:

RECIPIENT COPIES RECIPIENT COPIES ID CODE/NAME LTTR ENCL ID CODE/NAME LTTR ENCL PDS LA 1 1 PD5 PD 1 1 SAMWORTH,R 3 3 INTERNAL: ACRS 6 6 AEOD/DOA 1 1 AEOD/DSP/TPAB 1 1 NUDOCS-ABSTRACT 1 1 OGC/HDS2, 1 0 ILE 1 1 1 EXTERNAL: LPDR 1 0 NRC PDR 1 0 NOTE 'IO ALL 'KIDS" RECIPZEPIS:

PIZASE HELP US IO REDUCE MASTH! CGÃI'ACT 'IHE DOCUMEPZ CONTROL DESK, RXN Pl-37 (EZZ. 20079) m ELIKQQTE KN3R MME FRCH DISTRIBUTION LISTS HZt IXXXBKNTS %RJ DONFT NEEDI TOTAL NUMBER OF COPIES REQUIRED: LTTR 18 ENCL 15 fA 8'~

@~i WASHINGTON PUBLIC POWER SUPPLY SYSTEM

~ P.O. Box 968 ~ 3000 George Washington Way ~ Richland, Washington 99352 December 8, 1988 G02-88-262 Docket 50-397 U. S. Nuclear Regulatory Commission Attention: Document Control Desk Mail Stop Pl-137 Washington; DC 20555

Subject:

NUCLEAR PLANT NO. 2 OPERATIONAL LICENSE NPF-21 FUEL INSPECTION RESULTS At the request of Dr.. Shih Ling Wu; we enclose one copy of a report which describes the results of selected fuel inspections which have been carried out at HNP-2. These inspections were motivated; in part; by our concerns relating to the possibility of Crud Induced Localized Corrosion (CILC) on WNP-2 fuel. To date', significant nodular growth has not been observed on WNP-2 reload fuel.

Advanced Nuclear Fuels Corporation (ANF) considers the information contained in the enclosed topical report l.ANF-87-104(P)3 to be proprietary. In accordance with the Commission's Regulation 10 CFR 2.790; the enclosed affidavits executed by Mr. H. E. *Williamson of ANF and Mr. G. C. Sorensen of the Supply System provide the necessary information to support withholding of this topical report for, public disclosure.

G. C. Sorensen (MD 280)

Manager, Regulatory Programs WCH:dm Enclosure (As stated) cc: CJ Bosted; NRC (901A) w/o NS Reynolds; Bishop; Cook; Powell & Reynolds w/o RB Samworth; NRC w/o SL Hu', NRC w/o ht" 881208 PDR ADOCK 05000397 P PNU

STATE OF WASHINGTON) Subgect.

)

COUNTY OF BENTON ) g Iv F - P 7- /o V ( P~

I; G. C. Sorensen, being duly sworn; subscribe to and say that I am the Manager; Regulatory Progr ams for, the WASHINGTON PUBLIC POWER SUPPLY SYSTEM; the applicant herein; that I have full authority to execute this oath; that I have reviewed the foregoing; and that to the best of my knowledge, information and belief; the statements made in The attached it report ANF-87-104(P) is considered by the Advanced Nuclear are true.

Fuels Corporation as proprietary information. This report is treated as proprietary information by the Supply System. It is requested that said report be withheld from public disclosure under 10CFR 2.790.

DATE ~ ~C~ , 1988 G. C. Sorens n, Manage Regulatory Programs On this day personally appeared before me G. C. Sorensen to me known to be the individual who executed the foregoing instrument and acknowledged that he signed the same as his free act and deed for the uses and purposes herein mentioned.

GIVEN under my hand and seal this ~ day of 0 1988.

otary u s s n d or e OF WASHINGTO Residing at

AFFIDAVIT STATE OF WASHINGTON )

) ss.

COUNTY OF BENTON )

I, H. E. Williamson being duly sworn, hereby say and depose:

1. I am Manager, Licensing and Safety Engineering, for Advanced Nuclear Fuels Corporation, ("ANF"), and as such I am authorized to execute this Affidavit.
2. I am familiar with ANF's detailed document control system and policies which govern the protection and control of information.
3. I am familiar with the topical report ANF-87-104 (P),

Revisions 1 entitled "Inspection of ANF Fuel Assemblies 1163 and 1164 After 1 Cycle of Irradiation at the WNP-2 Reactor, May 1987", referred to as "Document." Information contained in this Document has been classified by ANF as proprietary in accordance with the control system and policies established by ANF for the control and protection of information.

4. The Document contains information of a proprietary and confidential nature and is of the type customarily held in confidence by ANF and not made available to the public. Based on my experience, I am aware that other companies regard information of the kind contained in the Document as proprietary and confidential.
5. The Document has been made available to the U.S. Nuclear Regulatory Commission in confidence, with the request that the information contained in the Document will not be disclosed or divulged.
6. The Document contains information which is vital to a competitive advantage of ANF and would be helpful to competitors of ANF when competing with ANF.
7. The information contained in the Document is considered to be proprietary by ANF because it reveals certain distinguishing aspects of BWR design which secure competitive advantage to ANF for fuel design optimization and marketability, and includes information utilized by ANF in its business which affords ANF an opportunity to obtain a competitive advantage over its competitors who do not or may not know or use the information contained in the Document.
8. The disclosure of the proprietary information contained in the Document to a competitor would permit the competitor to reduce its expenditure of money and manpower and to improve its competitive position by giving it valuable insights into BWR design and would result in substantial harm to the competitive position of ANF.
9. The Document contains proprietary information which is held in confidence by ANF and is not available in public sources.
10. In accordance with ANF's policies governing the protection and control of information, proprietary information contained in the Document has been made available, on a limited basis, to others outside ANF only as required and under suitable agreement providing for nondisclosure and limited use of the information.

ll. ANF policy requires that proprietary information be kept in a secured file or area and distributed on a need-to-know basis.

12. Information in this Document provides insight into BWR design developed by ANF. ANF has invested significant resources in developing the BWR design as well as the strategy for this application. Assuming a competitor had available the same background data and incentives as ANF, the

3 competitor might, at a minimum, develop the information for the same expenditure of manpower and money as ANF.

THAT the statements made hereinabove are, to the best of my knowledge, information, and belief, truthful and complete.

FURTHER AFFIANT SAYETH NOT.

SWORN TO AND SUBSCRIBED before me this N~ day of

~

1988.

4, fi J'.

a NOTARY~PURL;Ic'