IR 05000263/2019012
ML19331A737 | |
Person / Time | |
---|---|
Site: | Monticello ![]() |
Issue date: | 11/27/2019 |
From: | Hironori Peterson Division Reactor Projects III |
To: | Church C Northern States Power Co |
Shared Package | |
ML19331A305 | List: |
References | |
EA-19-066 IR 2019012 | |
Download: ML19331A737 (17) | |
Text
ber 27, 2019
SUBJECT:
MONTICELLO NUCLEAR GENERATING PLANT - FOLLOW-UP INSPECTION REGARDING THE ASSESSMENT AND MANAGEMENT OF SHUTDOWN RISK DURING THE REFUELING OUTAGE REPORT 05000263/2019012
Dear Mr. Church:
On September 20, 2019, the U.S. Nuclear Regulatory Commission (NRC) completed an inspection at the Monticello Nuclear Generating Plant. On September 24, 2019, the NRC inspectors discussed the results of this inspection with you and other members of your staff. A re-exit was conducted on November 22, 2019, with you and other members of your staff. The results of this inspection are documented in the enclosed inspection report.
One finding of very low safety significance (Green) is documented in this report. This finding involved a violation of NRC requirements. We are treating this violation as a non-cited violation (NCV) consistent with Section 2.3.2 of the Enforcement Policy.
If you contest the violation or the significance or severity of the violation documented in this inspection report, you should provide a response within 30 days of the date of this inspection report, with the basis for your denial, to the U.S. Nuclear Regulatory Commission, ATTN:
Document Control Desk, Washington, DC 20555-0001; with copies to the Regional Administrator, Region III; the Director, Office of Enforcement; and the NRC Resident Inspector at Monticello Nuclear Generating Plant.
If you disagree with a cross-cutting aspect assignment in this report, you should provide a response within 30 days of the date of this inspection report, with the basis for your disagreement, to the U.S. Nuclear Regulatory Commission, ATTN: Document Control Desk, Washington, DC 20555-0001; with copies to the Regional Administrator, Region III; and the NRC Resident Inspector at Monticello Nuclear Generating Plant. This letter, its enclosure, and your response (if any) will be made available for public inspection and copying at http://www.nrc.gov/reading-rm/adams.html and at the NRC Public Document Room in accordance with 10 CFR 2.390, Public Inspections, Exemptions, Requests for Withholding.
Sincerely,
/RA/
Hironori Peterson, Chief Branch 3 Division of Reactor Projects Docket No. 05000263 License No. DPR-22
Enclosure:
As stated
Inspection Report
Docket Number: 05000263 License Number: DPR-22 Report Number: 05000263/2019012 Enterprise Identifier: I-2019-012-0031 Licensee: Northern States Power Company, Minnesota Facility: Monticello Nuclear Generating Plant Location: Monticello, MN Inspection Dates: June 21, 2019 to September 20, 2019 Inspectors: D. Krause, Resident Inspector J. Nance, Senior Resident Inspector N. Shah, Project Engineer P. Zurawski, Senior Resident Inspector Approved By: Hironori Peterson, Chief Branch 3 Division of Reactor Projects Enclosure
SUMMARY
The U.S. Nuclear Regulatory Commission (NRC) continued monitoring the licensees performance by conducting a Follow-up Inspection Regarding the Assessment and Management of Shutdown Risk During the Refueling Outage at Monticello Nuclear Generating Plant, in accordance with the Reactor Oversight Process. The Reactor Oversight Process is the NRCs program for overseeing the safe operation of commercial nuclear power reactors. Refer to https://www.nrc.gov/reactors/operating/oversight.html for more information.
List of Findings and Violations Failure to Assess and Manage the Shutdown Risk at Monticello Cornerstone Significance Cross-Cutting Report Aspect Section Mitigating Green [H.14] - 71111.13 Systems NCV 05000263/2019012-01 Conservative Open/Closed Bias EA-19-066 The inspectors identified a Green finding and associated Non-cited Violation (NCV) of 10 CFR 50.65(a)(4) when the licensee failed to effectively assess and manage shutdown risk associated with concurrent maintenance activities, resulting in the degradation of of the decay heat removal and inventory control key safety functions during shutdown.
Additional Tracking Items Type Issue Number Title Report Section Status LER 05000263/2019-001-00 LER 2019-001-00 for 71153 Closed Monticello Nuclear Generating Plant, RHR Decay Heat Removal Pump Start Permissive Logic Hardening Error
PLANT STATUS
Monticello began the inspection period shutdown for Refueling Outage 29 (RFO29), which lasted until May 12, 2019. The unit commenced start-up on May 12, 2019, and attained 100 percent power on May 15, 2019. On June 1, 2019, the unit was down-powered to 73 percent for quarterly turbine and main steam isolation valve (MSIV) testing and returned to 100 percent the same day. On June 11, 2019, the unit was down-powered to 80 percent for a flexible power operation demonstration returning to 100 percent power the same day. To control discharge canal temperatures, the unit was down powered on three occasions. On July 15 & 18, 2019 to 90 percent and on July 19, 2019 to 80 percent. On September 14, 2019, the unit was down powered to 72 percent for quarterly turbine testing and control rod sequence exchange. The unit ended the inspection period at 100 percent power.
INSPECTION SCOPES
Inspections were conducted using the appropriate portions of the inspection procedures (IPs) in effect at the beginning of the inspection unless otherwise noted. Currently approved IPs with their attached revision histories are located on the public website at http://www.nrc.gov/reading-rm/doc-collections/insp-manual/inspection-procedure/index.html. Samples were declared complete when the IP requirements most appropriate to the inspection activity were met consistent with Inspection Manual Chapter (IMC) 2515, Light-Water Reactor Inspection Program - Operations Phase. The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel to assess licensee performance and compliance with Commission rules and regulations, license conditions, site procedures, and standards.
REACTOR SAFETY
71111.13 - Maintenance Risk Assessments and Emergent Work Control Risk Assessment and Management Sample (IP Section 03.01)
The inspectors evaluated the shutdown safety risk assessment for the April 2019 refueling outage, including the assessment and management of risk for concurrent management activities, between April 13 and 26, that directly impacted the key safety functions of decay heat removal and inventory control.
- (1) Loss of 1 sub-system of shutdown cooling from residual heat removal hardening -
Division 1
71111.15 - Operability Determinations and Functionality Assessments Operability Determination or Functionality Assessment (IP Section 02.02)
- (1) Loss of 13 Residual Heat Removal Pump due to residual heat removal hardening
OTHER ACTIVITIES - BASELINE
71153 - Follow-up of Events and Notices of Enforcement Discretion Event Report (IP Section 03.02)
The inspectors evaluated and closed the following licensee event reports (LERs):
- (1) LER 05000263/2019-001-00 for Monticello Nuclear Generating Plant, RHR Decay Heat Removal Pump Start Permissive Logic Hardening Error (ADAMS Accession:
ML19164A279). Additional details regarding the disposition of this LER are documented in the Results section.
INSPECTION RESULTS
Failure to Assess and Manage the Shutdown Risk at Monticello Cornerstone Significance Cross-Cutting Report Aspect Section Mitigating Green [H.14] - 71111.13 Systems NCV 05000263/2019012-01 Conservative Open/Closed Bias EA-19-066 The inspectors identified a Green finding and associated Non-cited Violation (NCV) of 10 CFR 50.65(a)(4) when the licensee failed to effectively assess and manage shutdown risk associated with concurrent maintenance activities, resulting in the degradation of the decay heat removal and inventory control key safety functions during shutdown.
Description:
Between April 13-26, 2019, the licensee failed to assess and manage the risk of concurrent maintenance activities that directly impacted the key safety functions of decay heat removal and inventory control. The aggregate impact of these activities caused all four residual heat removal (RHR) shutdown cooling sub-systems to be unavailable if the operating train failed for any reason, removed the ability to isolate the decay heat removal system during a potential loss of inventory event, and degraded an alternate decay heat removal path if it were needed during a loss of shutdown cooling event.
On April 13, 2019, at 1227, the licensee entered mode 4 and aligned Division 1 of RHR in shutdown cooling (SDC) mode, by starting the 11 RHR pump and placing the 13 RHR pump in SDC standby. Division 2 of RHR (i.e., the 12 and 14 RHR pumps) was aligned for the low-pressure coolant injection (LPCI) mode of operation, also in standby. At 1236, the licensee removed both RHR suction valves (MO-2029 and MO-2030) from service by opening and de-energizing the valves, in accordance with procedure 9111-05, Decay Heat Removal Hardening. The licensee used this procedure to prevent an inadvertent loss of SDC and was completed at approximately 1418. From 1531 on April 14 until 1838 on April 15, the licensee was in mode 5 with the reactor vessel in reduced inventory (i.e., <21.5 inches below the top of the reactor flange) to remove the reactor vessel head. At 2100 on April 15, the licensee completed flooding up the reactor and cavity in preparation for moving fuel. On April 16, at 0215, the licensee unsuccessfully attempted to start the 13 RHR pump to perform surveillance testing. Subsequently, the licensee determined that the pump did not start because RHR MO-2029 was de-energized. The licensee installed a jumper to restore remote start capability to the 13 RHR pump at 0431. The 11 RHR pump remained in-service for SDC. No actual loss of shutdown cooling event occurred.
Additionally, on April 13, 2019, at 1650, the licensee isolated air to all eight safety relief valves (SRVs) in the drywell and then closed the main steam isolation valve (MSIV) drain valves. The SRVs are used in alternate decay heat removal strategies as outlined in the licensees abnormal operating procedure C.4-B.03.04.A, Loss of Normal Shutdown Cooling.
Isolating air to the SRVs and closing the MSIV drain valves, left only one 2-inch reactor vent flow path, which is insufficient to prevent reactor coolant system heat-up, boiling, and re-pressurization if a loss of shutdown cooling occurred early in Mode 4. In addition, TS requirements and licensee procedures would direct closing the 2-inch vent path if Mode 3 transition was expected. This would impact alternate decay heat removal mitigation capability.
In the Shutdown Safety Plan, the licensee addressed the Key Safety Functions as follows:
- For Decay Heat Removal, the RHR shutdown cooling, reactor water cleanup (RWCU)and spent fuel pool subsystems would be available, to meet the required function and system redundancy.
- For Inventory Control, at least one core spray and/or RHR subsystem was available to provide low pressure injection to meet the required function and system redundancy.
The inspectors noted that as part of the Inventory Control evaluation, the licensee had not discussed the need for RHR isolation. As part of the risk assessment, the licensee reviewed the outage scope to identify the impact of activities on shutdown safety. Per procedure, this review was performed by individuals not responsible for developing the outage schedule and included, in part, identifying and evaluating first-time evolutions; ensuring that the shutdown Key Safety Functions were maintained, including maximizing the availability of key systems and components; that procedures for the loss of Key Safety Functions (such as Decay Heat Removal) could be performed as written; and identifying activities or configurations requiring contingency plans.
The licensee did a limited review of the outage scope that didnt address all of the above items. This resulted in a missed opportunity to assess and manage the actual impact on risk from de-energizing the RHR SDC isolation valves, isolating air to the SRVs, and closing the MSIV drain valves. Specifically, the licensee did not identify:
- that de-energizing both RHR suction valves was a first-time evolution which prevented the RHR pump starting logic from recognizing that an available suction path existed, resulting in none of the RHR pumps being available to restore SDC should the #11 RHR pump be lost;
- that isolating air to the SRVs prevented them from being used as a vent path in support of the Decay Heat Removal safety function had a loss of SDC occurred. This resulted in no other vent paths having adequate capacity to remove the decay heat load at that time in the outage and compromising those procedures addressing the loss of this Key Safety Function; and
- that the automatic isolation function should be maintained per the NUMARC guidance for Inventory Control, even though it wasnt required by TS. As a result, when the RHR SDC suction valves were de-energized, contingency plans should have been developed to either restore or otherwise address this safety function.
The inspectors also noted that the licensee had experienced a loss of shutdown cooling in 2015, after the position indication for one of the RHR suction valves was lost, activating the same RHR pump starting logic previously discussed. This operating experience was also not considered under the licensees limited review.
The inspectors noted that from April 14-15, when the reactor vessel was in reduced inventory, the estimated time to boil absent decay heat removal was 30 minutes. The definition of available in the corporate shutdown safety management program provides guidance on the simple manual actions that can be credited to consider an SSC available. It states that actions with implementing times approaching the time to boil are not reasonable and that credit should not be given for actions within 50 percent of the time to boil. It also states that the time available to perform any manual action should have substantial margin. Actions required for restoring the functions impacted by the inspection finding were not simple and did not in all cases have substantial time margin.
The inspectors concluded that the licensee had the plant knowledge and procedural guidance necessary to identify and address the effect that de-energizing the RHR SDC suction valves, isolating air to the SRVs, and closing the MSIV drain valves had on the shutdown safety functions of Decay Heat Removal and Inventory Control. Therefore, this finding was within the licensees ability to foresee and prevent. As a result, the licensee failed to properly assess and manage the shutdown risk in accordance with 10 CFR 50.65(a)(4).
Additionally, TS 3.4.8, required that at least two trains of RHR be operable to ensure that shutdown cooling is available. An RHR train was considered operable if it can be aligned either remotely or manually to provide SDC. By de-energizing the RHR suction valves, the valves position indication was inhibited into the RHR pump logic. Therefore, none of the RHR pumps would have started remotely for shutdown cooling as the pump logic would not have detected an available suction path; therefore, the requirements of TS 3.4.8 were not met.
Corrective Actions: Upon discovery of the inability to remotely start the 13 RHR pump, Operations installed a jumper in the start circuitry that allowed the pump to be started from the control room. A temporary change to the hardening procedure was created to add jumpers for all four RHR pumps to ensure the pump start permissive were maintained while the system was hardened.
Additional corrective actions to be implemented:
- Provide Operations case study on the requisite mindset for technical rigor;
- Perform Bypass review of the new hardening procedure in accordance with fleet procedure process;
- Change fleet procedure process to clarify definition of Important to Safety/Augmented Quality to allow proper classification of refueling outage Controlled Documents;
- Correct the safety classification of the hardening procedure to Augmented Quality; and
- Change fleet 50.59 procedure to clarify that application of Notes does not supersede Regulatory Review for changes to SSCs important to safety.
The licensee evaluated the efficacy of the outage shutdown risk management as part of QIP 501000027548, Shutdown Safety Lessons Learned from Apparent Cause Evaluation. In the evaluation, the licensee concluded that Monticello did not effectively implement the shutdown safety management program to ensure shutdown safety risk was appropriately managed for all outage conditions as required by 10 CFR 50.65(a)(4). Monticello staff did not properly assess the shutdown risk with the following plant configuration: 1) RHR Hardened with Shutdown Cooling Suction Valves open and de-energized; 2) SRVs and Main Steam Line Drains unavailable; 3) high decay heat load early in the shutdown. This lineup made unavailable all credited decay heat removal systems. In addition, this condition could have reduced vent capacity, such that reactor re-pressurization may have been possible had a loss of SDC actually occurred. In aggregate, these conditions impacted key shutdown safety functions which degraded plant safety.
This event was documented in LER 2019-001-00, RHR Decay Heat Removal Pump Start Permissive Logic Hardening Error.
Corrective Action References: QIP 501000025624: RHR Decay Heat Removal Hardening Issue Identified
Performance Assessment:
Performance Deficiency: The inspectors determined that the licensee failed to effectively assess and manage shutdown risk as required by 10 CFR 50.65(a)(4). Specifically, between April 13-26, 2019, the licensee failed to properly assess and manage the risk of concurrent maintenance activities that directly impacted the Key Safety Functions of Decay Heat Removal and Inventory Control. This was a performance deficiency that was within the licensees ability to foresee and correct and should have been prevented.
Screening: The inspectors determined the performance deficiency was more than minor because it was associated with the RCS Equipment and Barrier Performance attribute of the Mitigating Systems cornerstone and adversely affected the cornerstone objective to ensure the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences. Specifically, the licensee failed to evaluate the aggregate impact of de-energizing the RHR suction valves, isolating air to the SRVs, and then closing the MSIV drain valves, which caused all four RHR pumps to be inoperable, removed the ability to isolate the decay heat removal system during a potential loss of inventory event, and degraded an alternate heat removal path if it were needed during a loss of shutdown cooling event. The failure to assess and manage the risk from the above maintenance activities had an unrecognized, adverse effect on the licensees ability to maintain the shutdown safety functions for decay heat removal and inventory control.
Significance: The inspectors assessed the significance of the finding using Appendix G, Shutdown Safety SDP. The inspectors determined the performance deficiency was more than minor because it was associated with the reactor coolant system (RCS) Equipment and Barrier Performance attribute of the Mitigating Systems cornerstone. The inspectors evaluated the finding in accordance with NRC Inspection Manual Chapter (IMC) 0609, Appendix G, Attachment 1, Significance Determination Process (SDP) for shutdown operations, issued May 9, 2014, for Mitigating Systems, and determined the finding was required to be evaluated in Phase 2, per Appendix G, Attachment 3. Specifically, the answer to Exhibit 3 - Mitigating Systems Screening Questions, Question 2; Does the finding represent a loss of system safety function? was answered YES. The question was answered YES because if a loss of shutdown cooling, loss of inventory, or loss of offsite power event occurred, the mitigating functions of shutdown cooling, the implementation of alternate decay heat removal using safety relief valves (SRV), and the ability to isolate a loss of inventory event were impacted.
The inspector used IMC 0609, Appendix G, Attachment 1, Exhibit 3 Mitigating Systems, to screen this finding and determined that a detailed risk evaluation was required because the finding represented a loss of system safety function. Therefore, a coordinated effort between inspection staff and regional SRAs was required to arrive at an appropriate risk evaluation for the degraded condition that resulted from the finding.
The SRA evaluated the Phase 2 SDP Appendix G worksheets for the finding but made assumptions for mitigation credit beyond what was generally allowed by the guidance of the Phase 2 screening process. These assumptions were made after NRC risk analysts reviewed the plant degraded condition, procedures, training and discussed the response to the postulated shutdown initiating events with the licensee. Therefore, the modified Phase 2 SDP was a detailed risk evaluation or phase 3 SDP evaluation. The finding impacted the ability to mitigate all three of the shutdown initiating events modeled in Appendix G phase 2 loss of inventory, loss of the operating residual heat removal pump, and loss of offsite power.
The exposure period involved three shutdown plant operating states (POS): POS 1 was the condition when reactor water level was low, and the reactor head was on and tensioned; POS 2 was the condition when the reactor water level was low, and the reactor head was detensioned and/or off, or the reactor was sufficiently vented such that RCS re-pressurization cannot occur; and POS 3 was the condition when the reactor water level was high with the cavity flooded for refueling operations. The exposure time was less than 3 days for the impacts to the decay heat removal function in POS 1, 2, and 3. The exposure time for the impact to the ability to isolate a loss of inventory was a total of approximately 13 days, of which less than 3 days were in POS 1 and 2 and 10 days in POS 3.
Decay heat removal was an important function of shutdown risk assessment and management. In the shutdown safety plan, the licensee credited the RHR, reactor water cleanup and spent fuel pool systems, and other alternative means for meeting this function.
As stated, the RHR system was unavailable due to the RHR hardening actions. The licensee estimated that the time to boil was between 30-40 minutes during the event and that manually restoring shutdown cooling would have taken about 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> to complete. The ability to act within 50 percent of the time to boil was discussed in the licensees shutdown risk management procedure as a reasonable standard to apply for crediting manual actions to maintain system availability. Therefore, if the operating RHR pump failed for any reason, the operators would have been unable to restore shutdown cooling in a timely manner.
Additionally, the spent fuel pool system was not aligned to provide fuel cooling to the reactor vessel and the decay heat load exceeded the capability of the reactor water cleanup system.
The licensees alternative heat strategies relied on the safety relief valves (SRVs) and main steam isolation valve (MSIV) drain valves. Planned maintenance on April 13, 2019, resulted in air being isolated to all eight SRVs and the closure of the MSIV drain valves. These actions prevented the licensee from implementing the alternate decay heat removal strategy.
As a result, from April 14 to 15, the only available method for Decay Heat Removal was the running 11 RHR pump.
Inventory control was also an important function of shutdown risk assessment and management. The shutdown safety plan credited the core spray and LPCI systems for providing water injection into the vessel but did not address the ability to isolate the RHR system should there be a loss of inventory. Specifically, de-energizing the RHR suction valves, meant that these valves were unavailable to isolate a leak, until the function was restored on April 26. Although the isolation function was not required by TS, the NUMARC guidance specifically states that this key safety function be maintained. Therefore, from April 14 to 26, the licensee did not have a means to isolate the RHR system from the control room in a loss of inventory event.
Description of Degraded Condition If the running RHR pump stopped for any reason, the RHR decay heat removal function was determined to be unavailable but recoverable. On a loss of the operating RHR sub-system, attempts to restart the previously operating pump or the alternate pump in the same division would not be successful. However, operators could follow abnormal procedure C.4-B.03.04A, Loss of Normal Shutdown Cooling along with the normal operating procedure for RHR and the procedure for Decay Heat Removal Hardening to align the division of RHR previously aligned for low pressure coolant injection for shutdown cooling. At the beginning of the exposure time, information available to operators was that the time to boil was 30 minutes. After the discovery of the condition, the licensee estimated the time to boil at the beginning of the exposure period was closer to 40 minutes and the time to the RHR pressure isolation setpoint (75 psi) was slightly more than 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />. Although, the automatic isolation of RHR at 75 psi was disabled, procedures would direct operators to take manual action to isolate the system. The time to secure the previously operating division of RHR and start-up the standby division in accordance with procedures was estimated at approximately 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />.
The SRVs were also recoverable by entering the drywell and opening the instrument air isolation valves. No specific procedures were identified directing the operators to perform this recovery action, but the status of the SRVs was known to operators, the SRVs are referenced in the loss of decay heat removal procedure, and an SRV was used in a previous 2015 loss of shutdown cooling event as an alternate decay heat removal system. Adequate time was available, and conditions would be acceptable until significant boiling in the RCS occurred.
The loss of shutdown cooling procedure contained actions that would delay heat-up and subsequent RCS pressurization, such as increasing control rod drive (CRD) system flow and reactor water clean-up (RWCU) system operation. Note that the CRD and RWCU systems do not have sufficient capacity to prevent RCS boiling. The diagnosis and execution of the SRV recovery action was complex because of procedure ambiguity and a lack of training for actions in a loss of shutdown cooling event beyond recovery of the standby division of RHR.
The RHR shutdown cooling isolation valves MO-2029 and MO-2030 were open and could not be operated from the main control room in the event of a loss of inventory. This condition was known by the operators. Although these valves were recoverable, i.e., closeable by either restoring power to the valves or by manually closing the valves with the valve handwheels, there was no specific procedure guidance for this action nor was it described in any operator training for loss of inventory events. Actions to recover the valve function would involve removing tags, restoring power, and closing the valves from the control room or remote manual operation at the valve operator. The assumption inherent in the Appendix G worksheets and event trees was that 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> are available to isolate a leak prior to core damage without successful injection. The SRA assumed that restoring the valves to service could be performed within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />. Similar to the recovery of the SRVs, the diagnosis and execution of this recovery action was complex because of procedure ambiguity and a lack of training. During discussion with the licensee, there also appeared to be a belief that a loss of inventory event was not possible because of administrative controls. However, operating experience indicates that despite such controls, loss of inventory events can occur. The operating experience was reflected in the frequency of a loss of inventory event.
Several low pressure injection systems were available either automatically or via manual control room operation. The systems credited were two loops of low pressure core spray, one loop of low pressure coolant injection and condensate service water. The only high pressure injection system credited was the control rod drive (CRD) system. Both CRD pumps were available and only a single pump was necessary for adequate core cooling success if the RCS started to boil during a shutdown event. These injection systems were considered to be very reliable in the SDP evaluation.
Detailed Risk Evaluation Using SDP Phase 2 Worksheets For the loss of the operating train of RHR (LORHR) in POS 1 and 2 (see IMC 0609 Appendix G Attachment 3, Worksheets 4 and 5), the safety functions of decay heat removal recovery before RHR shutoff head (RHRREC) and Manual Low Pressure Injection and RCS Pressure Control (MINJ & SRV) were impacted by the finding. The analysts credited recovery after careful consideration of timing, procedure quality, and context specific training and experience. These functions were determined to be unavailable but recoverable and each was assigned a mitigation credit of 2 which represents a failure probability on the order of 1E-2. The failure probability was estimated using the guidance of NUREG/CR-6883, The SPAR-H Human Reliability Analysis Method and the evaluation of operator performance shaping factors for diagnosis and execution provided in the description of the degraded condition. If the functions had been available, the failure probability would be lower. The manual high pressure injection function (MINJY) was assigned a mitigation credit of 2. This system is provided additional credit using analyst judgment beyond the phase 2 guidance because two control rod drive pumps were available and operator action was not always necessary for success of the system. All other functions were assigned full mitigation credit consistent with Appendix G guidance. The dominant worksheet result was in POS 1, where the dominant core damage sequence was a loss of the operating RHR train, failure to recover RHR, successful injection at low pressure and recovery of SRVs and the failure to provide long term inventory control (this was Sequence 3 in Figure 7, Event Tree for Loss of RHR -
BWR POS-1, of Appendix G). The sequence was evaluated as a 7 which represents a change in core damage frequency on the order of 1E-7 per year. Similar results were obtained when solving the loss of offsite power worksheet but the sequences were one order of magnitude lower because the initiating event likelihood was smaller.
For the loss of inventory worksheets, the safety functions of isolation of the loss (ISOL),decay heat removal recovery before RCS pressure control (RHRREC), and RCS pressure control (SRV) were impacted by the finding. These functions were assumed to be unavailable but recoverable. The isolation function was assigned a mitigation credit of 1 which represents a failure probability on the order of 1E-1. The other two functions were treated the same as in the LORHR worksheet and assigned recovery credit of 2. All other functions were assigned full mitigation credit consistent with Appendix G guidance. The exposure period for POS 1 and 2 was less than three days and an initiating event likelihood of 4 was used based on Appendix G Table 4, Initiating Event Likelihood (IELs) for Condition Findings -BWRs. The POS 1 worksheet result provided one sequence of 7. The sequence was a loss of inventory event, successful automatic low pressure injection, failure to isolate the leak and failure to control RCS pressure. Using the same assumptions, the POS 2 worksheet did not provide any potentially significant sequences. The loss of inventory event in POS 3 was evaluated using a 13-day exposure time. The additional exposure time was modeled by using an initiating event likelihood of 3. However, these sequences also did not significantly contribute to the SDP result.
The overall result of the detailed risk evaluation/phase 3 SDP was a finding of very low safety significance or Green. The result was a change in CDF that was less than 1E-6 per year.
Because the result was greater than 1E-7, the SRA considered if the finding significance should be increased because of large early release (LERF) considerations by reviewing IMC 0609 Appendix H, Containment Integrity SDP. The low to moderate safety significance (white) threshold for LERF was 1E-7 per year. The drywell head was removed, thus primary containment was open (this was required in all BWR Mark I and II containment to conduct refueling operations). With containment open during the exposure period typically a LERF factor of 1.0 was applied, which indicates the core damage frequency was equal to the large early release frequency. The SRA concluded that the significance of the finding should not be increased for several reasons. The exposure period for the dominant scenarios was on the order of one day, less than the 3 day period assumed in the Phase 2 worksheets and which was not modified in the detailed risk evaluation. The two dominant core damage sequences involved scenarios in which emergency evacuation could be successful prior to any significant release if a core damage event occurred. The licensees emergency evacuation time estimate for 90 percent of the population in a 2 mile radius was slightly more than 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />. In the dominant sequences, the time from general emergency to core damage was likely longer than 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> and the potential for early declaration of a general emergency and early evacuation existed. Finally, the loss of RHR scenario would involve suppression pool scrubbing which would mitigate any release.
Summary of the Detailed Risk Evaluation The finding was determined to be of very low safety significance after a review of plant specific conditions primarily because the functions were recoverable, the low pressure systems and the control rod drive system were available for injection, and exposure time of the degraded safety functions in Mode 4 and early Mode 5 was short (less than 3 days).
Cross-Cutting Aspect: H.14 - Conservative Bias: Individuals use decision making-practices that emphasize prudent choices over those that are simply allowable. A proposed action is determined to be safe in order to proceed, rather than unsafe in order to stop. Specifically, the licensee failed to plan, control, and coordinate risk significant work activities, involving de-energizing the residual heat removal suction valves, and subsequently isolating air to the safety relief valves and closing the main steam isolation drain valves, to preclude impact on the key safety functions of decay heat removal and inventory control.
Enforcement:
Violation: Title 10 CFR 50.65(a)(4) requires, in part, that licensees assess and manage the increase in risk that may result from proposed maintenance activities.
Technical Specification 3.4.8, requires that two residual heat removal shutdown cooling subsystems be operable in mode 4 and, with no recirculation pump in operation, at least one residual heat removal pump shutdown cooling subsystem in operation. Condition A.1 states with one or two residual heat removal shutdown cooling subsystems inoperable verify an alternate method of decay heat removal is available for each inoperable residual heat removal shutdown cooling subsystem within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> and once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> thereafter.
Contrary to the above:
Between April 13 and 26, 2019, the licensee failed to assess and manage the increase in risk resulting from maintenance activities. Specifically, the licensee de-energized the residual heat removal suction valves; and, subsequently isolated air to the safety relief valves and then closed the Main Steam Isolation Valve drain valves without assessing and managing the increased risk from these coincident maintenance activities.
In addition, the licensee failed to comply with TS 3.4.8, from April 13-14, 2019, and while the reactor was in Mode 4, the licensee was not aware that by de-energizing the residual heat removal suction valves, the two residual heat removal subsystems were inoperable, and therefore did not take the Action required by TS 3.4.8.A.1.
Enforcement Action: This violation is being treated as an non-cited violation, consistent with Section 2.3.2 of the Enforcement Policy.
EXIT MEETINGS AND DEBRIEFS
The inspectors confirmed that proprietary information was controlled to protect from public disclosure.
- On November 22, 2019, the inspectors presented the Follow-up Inspection Regarding the Assessment and Management of Shutdown Risk During the Refueling Outage results to Mr. C. Church, Site Vice President, and other members of the licensee staff.
DOCUMENTS REVIEWED
Inspection Type Designation Description or Title Revision or
Procedure Date
71111.13 Corrective Action 501000025624 RHR DHR Hardening Issue Identified
Documents 501000025683 Procedure Reviews for 9111-05
Engineering USA Outage Excellence Standard 7.0; Implementation and 0
Evaluations Management of Shutdown Safety at USA Stations
Monticello Nuclear Generating Plant Shutdown Safety Plan 0
Refueling Outage 29
BWROG-TP-15- RHR System Improvement Committee (321), RHR Shutdown 0
013 Cooling Protection Best Practices
Procedures 4 AWI-08.15.03 Risk Management for Outages 15
9111-05 Decay Heat Removal Hardening 1
B.03.04-05 Residual Heat Removal System Operation 88
FP-E-MOD-02 Engineering Change Control 26
FP-OP-ROM-01 Refueling Outage Management 15
FP-OP-ROM-02 Shutdown Safety Management Program 10
71111.15 Corrective Action 501000025764 Protected Equipment for RFO 29
Documents
Drawings NE-36404-4 RHR Pump P-202A, ACB 152-504 Control 78
NX-7823-4-11C RHR Shutdown Cooling Supply Inboard Isolation Valve, MO- 76
29 - Scheme B3333
NX-7823-4-11D RHR Shutdown Cooling Supply Outboard Isolation Valve 76
MO-2030 - Scheme D31307
NX-7905-46-3 S/D Residual Heat Removal System 77
Procedures 9111-01 Shutdown Cooling Division 1 Protected System Ticket 10
Checklist
9111-02 Shutdown Cooling Division II Protected System Ticket 9
Checklist
C.4-B.03.04.A Loss of Normal Shutdown Cooling 15
FP-OP-PEQ-01 Protected Equipment Program 21
OWI-03.03 RPV Water Inventory Control 14-A
Self-Assessments 501000025624 Apparent Cause Evaluation (ACE) for RHR DHR Hardening 0
Issue identified
71153 Corrective Action 501000027548 Shutdown Safety Lessons Learned from ACE
Inspection Type Designation Description or Title Revision or
Procedure Date
Documents 501000029538 RCE IDd RFO29 SRV Impact Stmt, CO errors
Drawings NX-7905-46-4 Residual Heat Removal S/D System 77
NX-7905-46-8 Schematic Diagram; Residual Heat Removal System 78
Procedures 4 AWI-04.04.03 Bypass Control 45
9111-01 Shutdown Cooling Division 1 Protected System Ticket 11
Checklist
9111-05 Decay Heat Removal Hardening 3
FP-OP-ROM-01 Refueling Outage Management 16
OWI-03.03 RPV Water Inventory Control 15
14