SUBJECT:
MONTICELLO NUCLEAR GENERATING PLANT-INTEGRATED INSPECTION REPORT 05000263/2023004
Dear Shawn Hafen:
On December 31, 2023, the U.S. Nuclear Regulatory Commission (NRC) completed an inspection at Monticello Nuclear Generating Plant. On January 11, 2024, the NRC inspectors discussed the results of this inspection with you and other members of your staff. The results of this inspection are documented in the enclosed report.
No findings or violations of more than minor significance were identified during this inspection.
This letter, its enclosure, and your response (if any) will be made available for public inspection and copying at http://www.nrc.gov/reading-rm/adams.html and at the NRC Public Document Room in accordance with Title 10 of the Code of Federal Regulations 2.390, Public Inspections, Exemptions, Requests for Withholding.
Sincerely, Hironori Peterson, Chief Reactor Projects Branch 3 Division of Operating Reactor Safety Docket No. 05000263 License No. DPR-22
Enclosure:
As stated
Inspection Report
Docket Number:
05000263
License Number:
Report Number:
Enterprise Identifier:
I2023004-0053
Licensee:
Northern States Power Company, Minnesota
Facility:
Monticello Nuclear Generating Plant
Location:
Monticello, MN
Inspection Dates:
October 01, 2023 to December 31, 2023
Inspectors:
B. Bergeon, Senior Operations Engineer
N. Bolling, Project Engineer
A. Demeter, Resident Inspector
J. Kutlesa, Emergency Preparedness Inspector
T. McGowan, Resident Inspector
C. Norton, Senior Resident Inspector
T. Wingfield, Operations Engineer
Approved By:
Hironori Peterson, Chief
Reactor Projects Branch 3
Division of Operating Reactor Safety
SUMMARY
The U.S. Nuclear Regulatory Commission (NRC) continued monitoring the licensees performance by conducting an integrated inspection at Monticello Nuclear Generating Plant, in accordance with the Reactor Oversight Process. The Reactor Oversight Process is the NRCs program for overseeing the safe operation of commercial nuclear power reactors. Refer to https://www.nrc.gov/reactors/operating/oversight.html for more information.
List of Findings and Violations
No findings or violations of more than minor significance were identified.
Additional Tracking Items
None.
PLANT STATUS
The unit began the inspection period in Mode 4. On October 6, 2023, the licensee transitioned the unit to Mode 2 and commenced a reactor startup. The unit reached rated thermal power on October 8, 2023. On December 19, 2023, the licensee lowered reactor power to 32 percent of rated thermal power to perform a control rod sequence exchange and clean the water box side of the main condenser. On December 21, 2023, the licensee returned the unit to rated thermal power. The unit remained at or near rated thermal power for the remainder of the inspection period.
INSPECTION SCOPES
Inspections were conducted using the appropriate portions of the inspection procedures (IPs) in effect at the beginning of the inspection unless otherwise noted. Currently approved IPs with their attached revision histories are located on the public website at http://www.nrc.gov/reading-rm/doc-collections/insp-manual/inspection-procedure/index.html. Samples were declared complete when the IP requirements most appropriate to the inspection activity were met consistent with Inspection Manual Chapter (IMC) 2515, Light-Water Reactor Inspection Program - Operations Phase. The inspectors performed activities described in IMC 2515, Appendix D, Plant Status, observed risk significant activities, and completed onsite portions of IPs. The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel to assess licensee performance and compliance with Commission rules and regulations, license conditions, site procedures, and standards.
REACTOR SAFETY
71111.01 - Adverse Weather Protection
Seasonal Extreme Weather Sample (IP Section 03.01) (1 Sample)
- (1) The inspectors evaluated readiness for seasonal extreme weather conditions prior to the onset of seasonal cold temperatures for the following systems:
Heating boiler, cooling towers, reactor building chilled water system, and intake structure on October 26, 2023
71111.04 - Equipment Alignment
Partial Walkdown Sample (IP Section 03.01) (1 Sample)
The inspectors evaluated system configurations during partial walkdowns of the following systems/trains:
- (1) Control rod drive SCRAM solenoid valves energized prior to performing 0010 reactor SCRAM functional test on November 21, 2023
71111.05 - Fire Protection
Fire Area Walkdown and Inspection Sample (IP Section 03.01) (5 Samples)
The inspectors evaluated the implementation of the fire protection program by conducting a walkdown and performing a review to verify program compliance, equipment functionality, material condition, and operational readiness of the following fire areas:
(1)125V division 1 battery room on October 24, 2023 (2)250V division 1 battery room on October 24, 2023
- (3) East shutdown cooling area on October 26, 2023
- (4) West shutdown cooling area on October 26, 2023
- (5) Lube oil storage tank room on November 15, 2023
Fire Brigade Drill Performance Sample (IP Section 03.02) (1 Sample)
- (1) The inspectors evaluated the onsite fire brigade training and performance during an announced fire drill on November 11, 2023.
71111.06 - Flood Protection Measures
Flooding Sample (IP Section 03.01) (1 Sample)
- (1) The inspectors evaluated external flooding mitigation protections for beyond design bases flooding
71111.11A - Licensed Operator Requalification Program and Licensed Operator Performance
Requalification Examination Results (IP Section 03.03) (1 Sample)
- (1) The inspectors reviewed and evaluated the licensed operator examination failure rates for the requalification annual operating exam and the biennial written examinations administered from September 11, 2023, through October 26, 2023.
71111.11B - Licensed Operator Requalification Program and Licensed Operator Performance
Licensed Operator Requalification Program (IP Section 03.04) (1 Sample)
- (1) Biennial Requalification Written Examinations The inspectors evaluated the quality of the licensed operator biennial requalification written examination administered on October 5, 2023.
Annual Requalification Operating Tests The inspectors evaluated the adequacy of the facility licensees annual requalification operating test.
Administration of an Annual Requalification Operating Test The inspectors evaluated the effectiveness of the facility licensee in administering requalification operating tests required by 10 CFR 55.59(a)(2) and that the facility licensee is effectively evaluating their licensed operators for mastery of training objectives.
Requalification Examination Security The inspectors evaluated the ability of the facility licensee to safeguard examination material, such that the examination is not compromised.
Remedial Training and Reexaminations The inspectors evaluated the effectiveness of remedial training conducted by the licensee and reviewed the adequacy of reexaminations for licensed operators who did not pass a required requalification examination.
Operator License Conditions The inspectors evaluated the licensees program for ensuring that licensed operators meet the conditions of their licenses.
Control Room Simulator The inspectors evaluated the adequacy of the facility licensees control room simulator in modeling the actual plant, and for meeting the requirements contained in 10 CFR 55.46.
71111.11Q - Licensed Operator Requalification Program and Licensed Operator Performance
Licensed Operator Requalification Training/Examinations (IP Section 03.02) (1 Sample)
- (1) The inspectors observed and evaluated licensed operator crew simulator exam on October 17, 2023.
71111.12 - Maintenance Effectiveness
Maintenance Effectiveness (IP Section 03.01) (4 Samples)
The inspectors evaluated the effectiveness of maintenance to ensure the following structures, systems, and components (SSCs) remain capable of performing their intended function:
- (1) Planned maintenance of division 1 standby gas treatment system on November 6, 2023
- (2) Y81 inverter maintenance performed week of November 6, 2023
- (3) D70 battery charger feeder breaker B443, major preventive maintenance on November 15, 2023
- (4) Division 1 core spray maintenance work window during week of November 11, 2023
Quality Control (IP Section 03.02) (1 Sample)
The inspectors evaluated the effectiveness of maintenance and quality control activities to ensure the following SSC remains capable of performing its intended function:
- (1) Replacement of piping associated with VCH1 reactor building chiller system on November 08, 2023
71111.13 - Maintenance Risk Assessments and Emergent Work Control
Risk Assessment and Management Sample (IP Section 03.01) (5 Samples)
- (1) Risk assessment associated with removing FLEX forklift from storage location on October 30, 2023
- (2) Removing VAH1 & 2(smoke exhaust from turbine deck) from service to support maintenance on November 8, 2023
- (3) Attempting to close the main generator output breaker 8N8 on November 9, 2023
- (4) Evaluated the risk of leaving a control rod hydraulic control unit accumulator between the SCRAM banks on November 14, 2023
- (5) Elevated risk due to online high pressure coolant injection system maintenance, on December 18, 2023
71111.15 - Operability Determinations and Functionality Assessments
Operability Determination or Functionality Assessment (IP Section 03.01) (5 Samples)
The inspectors evaluated the licensees justifications and actions associated with the following operability determinations and functionality assessments:
(1)
===501000077866, air conditioner VEAC14A compressor motor oil leak (2)501000078149, local power range monitors affected by online noble chemistry (3)501000079161, 1AR transformer LTC lockout alarm (4)501000079244, water in oil sample P208B, division 2 core spray pump (5)501000080176, B pressure control damper failed to open on B control room ventilation
71111.18 - Plant Modifications
Temporary Modifications and/or Permanent Modifications (IP Section 03.01 and/or 03.02)
=
The inspectors evaluated the following temporary or permanent modifications:
(1)50.59 Screening, closing of the outboard low pressure coolant injection valve if minor leakage past the inboard injection valve results in pressurizing the residual heat removal system
- (2) Plug installed in the standby liquid control system using alternate plant configuration process, FPOP-SC02
- (3) Temporary modification installed for defeating division 1 250Vdc ground associated with SRV G
71111.20 - Refueling and Other Outage Activities
Refueling/Other Outage Sample (IP Section 03.01) (1 Sample)
- (1) The inspectors evaluated a forced outage from September 27, 2023, to October 6, 2023, following a reactor scram occurring during turbine control valve testing.
71111.24 - Testing and Maintenance of Equipment Important to Risk
The inspectors evaluated the following testing and maintenance activities to verify system operability and/or functionality:
Post-Maintenance Testing (PMT) (IP Section 03.01) (6 Samples)
- (1) EDG 12 air tank relief valve testing (RV3224, RV3325, RV3226) after replacement on October 24, 2023
- (2) Post-maintenance test of division standby gas treatment system following filter element replacement and charcoal sampling on November 8, 2023
- (3) Post-maintenance test of B443 (feed breaker) for the D70 250Vdc battery charger (division 2) after major preventive maintenance performed on November 15, 2023
- (4) Post-maintenance test of diesel fire pump after pressure control valve replacement on November 17, 2023
- (5) Post-maintenance test of liquid radwaste level transmitter (LT2649) associated with waste surge tank (T23) on November 20, 2023
- (6) Post-modification test to bypass the 01 digit from control rod position indication system for control rod 1407 on November 20, 2023
71114.04 - Emergency Action Level and Emergency Plan Changes
Inspection Review (IP Section 02.0102.03) (1 Sample)
- (1) The inspectors evaluated the following submitted Emergency Action Level and Emergency Plan changes.
- MT2022768_A.2422_A.2423 of July 14, 2022
- MT2022769_A.2419 of August 5, 2022
- MT2023775_ECR 601000002262 of March 28, 2023
- MT2023776 of April 17, 2023
- EPLAN01 Revision 0
- EPLAN02 Revision 2 This evaluation does not constitute NRC approval.
OTHER ACTIVITIES-BASELINE
===71151 - Performance Indicator Verification The inspectors verified licensee performance indicators submittals listed below:
MS09: Residual Heat Removal Systems (IP Section 02.08)===
- (1) October 1, 2022 through September 30 2023
MS10: Cooling Water Support Systems (IP Section 02.09) (1 Sample)
- (1) October 1, 2022 through September 30 2023
71152A - Annual Follow-up Problem Identification and Resolution Annual Follow-up of Selected Issues (Section 03.03)
The inspectors reviewed the licensees implementation of its corrective action program related to the following issues:
- (1) Housekeeping trends after hydraulic control accumulator left unsecured between SCRAM banks
71152S - Semiannual Trend Problem Identification and Resolution Semiannual Trend Review (Section 03.02)
- (1) The inspectors reviewed the licensees corrective action program for potential adverse trends in the use of wireless gauge readers (WGR) throughout the plant that might be indicative of a more significant safety issue. The inspectors observed multiple corrective actions documents related to improper installation of WGR on non-safety significant related systems as well as concerns of event response due to the presence of WGR in the field. The inspectors reviewed all corrective action documents related to WGR and had further discussions with the project owner to confirm WGR have not been improperly installed on safety-related equipment, and actions to correct any adverse conditions were corrected.
No findings or violations of NRC requirements of more than minor safety significance were identified by the inspectors in the course of this review.
INSPECTION RESULTS
Observation: Housekeeping Trends After Hydraulic Control Unit Accumulator Left Unsecured Between SCRAM Banks 71152A While performing plant status walkdowns on November 14, 2023, during the planned replacement of a control rod drive hydraulic control unit accumulator, the inspectors observed the old accumulator left unsecured between the SCRAM banks. The inspectors raised this concern to the work control senior reactor operator. The licensee took prompt action to secure the accumulator and evaluate the risk. This item was entered into their corrective action program (CAP) 501000079045.
The implementing procedure used to control this seismic concern was FPGEN-HSK01, Housekeeping. Specifically, Attachment 72.e states, items weighing 200 lbs. or more SHALL be secured when near sensitive safety related instrumentation. The licensee performed an evaluation that showed the accumulator would not damage the scram banks in the design base earthquake due to 4-inch curbs located on the bottom of the scram banks.
The inspectors reviewed the requirements of the housekeeping procedure and concluded further walkdowns of plant areas were warranted to verify compliance. The following additional observations were made by NRC inspectors.
FPGEN-HSK01 5.1.8 states, Site personnel shall ensure that no objects that could compromise the integrity or effectively reduce the height of a locked high radiation barrier are placed or stored within three feet of the barrier. On November 20, 2023, inspectors observed the effective height of locked high radiation fence located on the turbine deck to be below 6 feet. The licensee entered item into their CAP as 501000079184.
FPGEN-HSK01 5.8.2 states, Large storage container owners shall conduct a quarterly inspection of the interior contents of large storage containers. On November 20, 2023, the inspectors identified during a discussion with the radiation protection manager that quarterly inspections of large storage boxes were not conducted or exempted. The licensee entered this into their CAP as 501000079179.
FPGEN-HSK01 5.1.212 states, Keep tools and equipment away from areas that could affect plant equipment performance and establish barriers if necessary. On November 28, 2023, inspectors identified a ladder improperly stored next to the site protected area fence. The licensee entered item into their CAP as 501000079455.
The inspectors determined that these observations demonstrate a potential lack of adherence to FPGEN-HSK01, Housekeeping. The inspectors did not identify any findings or violations of a more than minor significance associated with the inspection activities.
EXIT MEETINGS AND DEBRIEFS
The inspectors verified no proprietary information was retained or documented in this report.
- On January 11, 2024, the inspectors presented the integrated inspection results to S. Hafen, Site Vice President, and other members of the licensee staff.
- On October 5, 2023, the inspectors presented the licensed operator biennial requalification program inspection results to S. Spillum, Training Director, and other members of the licensee staff.
- On October 26, 2023, the inspectors presented the licensed operator annual requalification program inspection results to R. Becker, Lead Exam Author, and other members of the licensee staff.
- On December 7, 2023, the inspectors presented the emergency action level and emergency plan changes inspection results to K. Nyberg, Director Site Performance & Ops Support, and other members of the licensee staff.
DOCUMENTS REVIEWED
Inspection
Procedure
Type
Designation
Description or Title
Revision or
Date
Procedures
2000018229
Winter Checklist
11/21/2022
Procedures
0010
Reactor SCRAM Functional Test
Fire Plans
STRATEGY A.313-A
Fire Zone 13A Lube Oil Storage Tank Room
Drill Guide 14A.01
MCC 121 Fire
11/11/2023
Miscellaneous
Fire Strategy A.314-A
Upper 4KV Bus Area (14 &16)
2176
Fire Drill Procedure
Strategy A.302-G
Fire Zone 2G East Shutdown Cooling Area
Strategy A.302-H
Fire Zone 2H West Shutdown Cooling Area
Strategy A.307-A
Fire Zone 7A 125V Division 1 Battery Room
Procedures
Strategy A.307-B
Fire Zone 7B 250V Division 1 Battery Room
Drawings
NH04545PID
Groundwater Remediation
ECR 601000004545
Ground Hardening
Engineering
Evaluations
FPPE-HAZ01
External Flooding Program
Procedures
1478
External Flood Monthly and Annual Surveillance
Miscellaneous
Requalification Program Annual
Testing Summary Results
Licensed Operator Annual Examination
Performance Records for 2023
10/26/2023
501000058724
Delay of Simulator Training
2/01/2021
501000063552
Unexpected Simulator Response
06/02/2022
501000063928
EP Drill-Simulator Crash
06/14/2022
501000070511
Adverse Trend in Shift Manager
DEP Performance
2/08/2023
501000074912
06/28/2023
Corrective
Action
Documents
501000077353
0089 Figure Non-Conserv WRT LCO 3.1.7
10/04/2023
Discipline Training Committee
Agenda/Minutes
01/11/2022
Discipline Training Committee
Agenda/Minutes
05/31/2022
Discipline Training Committee
Agenda/Minutes
09/20/2022
Miscellaneous
Discipline Training Committee
Agenda/Minutes
01/18/2022
Inspection
Procedure
Type
Designation
Description or Title
Revision or
Date
Discipline Training Committee
Agenda/Minutes
2/14/2023
JPM0089001
JPM-B.03.04011
Place Shutdown Cooling in Service
JPM-B.05.09001
Control Valve Oscillations Requiring Use of Load
Limit
JPM-B.09.06.05003
Transfer Plant Buses from 2R to 1R Using the
Emergency Method
JPM-C.4B.06.03.A001
Decreasing Condenser Vacuum
JPM-C.53101-002
Depressurize the SCRAM Air Header Locally
per C.53101
JPM-C.53101-005
Deenergize SCRAM Logic
JPM-C.53204-001
JPM-C.53206-001
Determine Validity of Reactor Level Instruments
JPM-C.53302-006
Defeat RCIC Low-Low Level Initiation Signals
QF108101 CP01
CP01 Core Stability and Power Distribution
04/11/2023
QF108101 CP02A
CP02A Poison Effects After a SCRAM
04/26/2023
QF108101 CP02B
CP02B Poison Effects Following Reactor
Startup
04/27/2023
QF108101 CP02C
CP02C Poison Effects Following a Reactor
05/08/2023
QF108101 CP07
CP07 Shutdown Margin Demonstration
05/05/2023
QF108101 CP08
CP08 SBLC Injection from 100%
Power Cycle 31
04/20/2023
QF108101 CP09
CP09 BOC Reactor Critical Verification
05/31/2023
QF108101 N01
N01 Unit Startup from Cold Shutdown
2/15/2023
QF108101 N02
N02 Unit Shutdown from Rated Power to Hot
Standby and Cooldown to Cold Shutdown
Conditions
03/13/2023
QF108101 SSP01
SSP01 Steady State Performance
06/07/2023
QF108101 T01
T01 Manual Scram
04/10/2023
QF108101 T02
T02 Simultaneous Trip of All Feedwater Pumps
04/10/2023
Inspection
Procedure
Type
Designation
Description or Title
Revision or
Date
QF108101 T03
T03 Simultaneous Closure of All Main Steam
Isolation Valves
04/21/2023
QF108101 T04
T04 Simultaneous Trip of All Recirculation
Pumps
04/21/2023
QF108101 T05
T05 Single Recirculation Pump Trip
04/21/2023
QF108101 T06
T06 Main Turbine Trip from Maximum Power
Level which does Not Result in Immediate
Reactor SCRAM
04/21/2023
QF108101 T07
T07 Maximum Rate Power Ramp Down to
Approximately 75 Percent and Back up to
100 Percent
04/10/2023
QF108101 T08
T08 Maximum Size Reactor Coolant System
Rupture Combined with Loss of all Offsite Power
04/10/2023
QF108101 T09
T09 Maximum Size Unisolable Main Steam Line
Rupture
04/10/2023
QF108101 T10
T10 Simultaneous Closure of all Main Steam
Isolation Valves Combined with Single Stuck
Open Safety or Relief Valve (Inhibit Activation of
High-Pressure Emergency Core Cooling
Systems)
04/10/2023
QF108101 XX01
XX01 Simulator Real Time Measurement
04/10/2023
QF108101 XX07
XX07 Simulator Repeatability
04/10/2023
Remediation Training Plans
Remediation Training Plans 10/2021-08/2023
RO3A
Reactor Operator Written Examination
(Version 3A)
09/11/2023
RQSS178
RPV Flood
RQSS198
LONOP With a Loss of Torus Water Level
RQSS199
Bus 11 Lockout with Small LOCA and Loss of
High-Pressure Feed Requiring Blowdown
RQSS200
Loss of Stator Water Cooling with High Power
Simulator Deviation List
Current List Simulator Deviations
09/18/2023
Inspection
Procedure
Type
Designation
Description or Title
Revision or
Date
SRO3A
Senior Reactor Operator Written Examination
(Version 3A)
09/11/2023
SWR 2021DR001
F SRV Operation During SBO Load Shed
01/08/2021
SWR 2021MD016
Backout LPCI Loop Select Setpoint Change
06/18/2021
SWR 2021MD024
New Malfunction - SRV Relief Vacuum Valve
Failure
11/28/2021
SWR 2022MD004
EC - 11 & 12 RHR Pump Motor Replacement
2/07/2022
SWR 2023DR009
Drywell Pressure Limit of Simulation
06/07/2023
SWR 2023DR014
Rising Torus Temp with Makeup from Core
Spray
08/28/2023
SWR 2023MD001
G SRV Tailpipe Alarm TMod Setpoint Change
01/18/2023
SWR 2023MD002
CWO 611000004307 and 611000004316
2/03/2023
SWR 2023MD005
601000004482 TMOD for Bypass TE152R for
Rec MG Rear Brng
06/12/2023
Training Attendance Records
Training Attendance Records
08/30/2023
FLLOR
Fleet Licensed Operator Requalification
FPT-SAT71
NRC Exam Security Requirements
FPT-SAT73
Licensed Operator Requalification Program
Examinations
FPT-SAT81
Simulator Testing and Documentation
Procedures
OWI03.07
Time Critical Operator Actions
Self-
Assessments
SAR 606000002021
23 71111.11 Inspection Self-Assessment
Report
08/22/2023
700090913
1440 NRC License Active Status Maint.
Fourth Quarter 2021
03/23/2022
700095581
1440 NRC License Active Status Maint.
First Quarter 2022
06/23/2022
700099685
1440 NRC License Active Status Maint.
Second Quarter 2022
10/19/2022
700103707
1440 NRC License Active Status Maint.
Third Quarter 2022
11/16/2022
Work Orders
700107500
1440 NRC License Active Status Maint.
Fourth Quarter 2022
03/16/2023
Inspection
Procedure
Type
Designation
Description or Title
Revision or
Date
700111283
1440 NRC License Active Status Maint.
First Quarter 2023
06/14/2023
700116483
1440 NRC License Active Status Maint.
Second Quarter 2022
04/06/2023
700120072
1440 NRC License Active Status Maint.
Third Quarter 2022
07/10/2023
Miscellaneous
RQSS173
Reactor Flood
501000073154
Y81 Failure Caused Plant Transient
05/04/2023
Corrective
Action
Documents
501000076959
Loss of Current Signal on Y81 Recorder
09/21/2023
NE364716
144480 MCC B44
11/15/2023
NF362981
Electrical Load Flow One Line Diagram
11/15/2023
Drawings
NF362982
DC Electrical Load Distribution One Line
11/15/2023
27PM
Klockner-Moeller B34 and B44 Maintenance
Procedure
417001-PM
SBGT Train A Moisture Eliminators, Charcoal
Adsorbers and HEPA Filters Cycle PM
4848PM
Klockner-Moeller Thermal Overload Relay Test
Procedure
Procedures
4875PM
Klockner-Moeller Molded Case Circuit Breaker
Maintenance and Test Procedure
700091581
41701 A SBGT Moisture Separator
Demister T34A1
11/06/2023
7001041300020
VCH1 (New Piping Fabrication with QC Hold
Points)
11/08/2023
700108842
8443Major PM (D70, Charger for D6B 16
Battery)
11/15/2023
7001088420010
B443 - Major PM
11/15/2023
700121418
Core Spray Pump Motor (137601-01,
CSP Div A Pump Motor Oil Subsystem)
11/11/2023
Work Orders
700123423
Division 2 120VAC Class 1E Inverter Failure
11/06/2024
501000078357
FLEX Equipment Removed from WH6
10/30/2023
Corrective
Action
501000079045
Removed Cylinder Not Chocked
11/15/2023
Inspection
Procedure
Type
Designation
Description or Title
Revision or
Date
Documents
Drawings
NH23994947-4
345 8N8 Closing
Miscellaneous
PRA-MTSY-HVAC
HVAC System Notebook
5.1
417001-PM
SBGT Train A Moisture Eliminators, Charcoal
Absorbers, and HEPA Filters Cycle PM
7136
HPCI System Instrument Maintenance
FPBDB-EQP01
Equipment Important to BDB Compliance
FPGEN-HSK01
Housekeeping
Procedures
OSP-HPC0056
HPCI Steam Flow Pressure Sensor Test and
Calibration
Work Orders
7001296110043
Close 8N8 Output Breaker
501000077866
Air Conditioner VEAC14A Compressor Motor
Oil Leak
501000078149
10/25/2023
501000079161
1AR LTC Lockout Alarm
11/18/2023
501000079244
Water in Oil Sample of 12 Core Spray Pump
Upper Motor Bearing
11/21/2024
Corrective
Action
Documents
501000080176
VD9175B Failed to Open on B CRV
2/20/2023
Procedures
0465
Emergency Filtration Treatment System
Corrective
Action
Documents
501000078279
Process Shortfalls SBLC Test Tank Plug
10/27/2023
50.59 Screening 190062
Update ARP C.6003-A03
Engineering
Evaluations
60800000430
Pressure of the Water Trapped Between the
Inboard and Outboard LPCI Isolation Valves and
the Relative Opening Speed of the Valves
25503-III
SBLC Quarterly Pump and Valve Tests
ARP C.6003-A03
RHR I/II Discharge Shutdown Headers on
HI Press
Procedures
FPOP-SC02
Alternate Plant Configuration Control
Corrective
Action
Documents
501000079210
LT2649 Sensing Line Needs Replacement
11/20/2023
Inspection
Procedure
Type
Designation
Description or Title
Revision or
Date
Drawings
NH36045
P&ID Clean Radwaste System
Engineering
Changes
601000004648
Bypass Indication Signal on CR 1407
014701
A Standby Gas Treatment System Filter Tests
261
Fire Pump Exercise and Fuel Quantity Check
2300
Reactivity Adjustment
4190PM
Diesel Engine, Fire Protection Pump
Procedures
7311
Liquid Radwaste LRW1 Instrument PM
7000761020030
PMT (Relief Valve Replacement for T80A,
T80B, and T80C)
10/24/2023
7001088420020
B4433, PMT D70, Charger for D6B 16 Battery
11/15/2023
700115167
P1054190-PM (Annual) EPA Air Permit
11/17/2023
Work Orders
700121135020
LT2649 (Sensing Line D, Waste Surge Tank
Level)
11/20/2023
Engineering
Changes
MT2023775_ECR
601000002262
Cycle 32 Core Reload Modification Required
Calculation Revision of CA 04194 and
CA 04202
03/28/2023
MT2022768_A.2422_A.2423
Updated Correction Factor for Stack and Reactor
Building Vent Iodine/Particulate Sampling
Procedure
07/14/2022
MT2022769_A.2419
Editorial Changes to Procedure
A.2419_PCR602000024225
08/05/2022
Miscellaneous
MT2023776
Procedure Revision to Emphasize NRC
Notification Within 1 Hour of Declared
Emergency
04/17/2023
EPLAN01
Standard Emergency Plan
Procedures
EPLAN02
Monticello Emergency Plan Annex
Miscellaneous
MSPI QF0445 Packet
NRC and MOR Data Collection and Submittal
Form (FPRPI01); Review of MS09 and MS10
(uploaded in CERTREC)
11/02/2023
71151
Procedures
FPRPI01
Preparation of NRC Performance Indicators
501000079045
Removed Cylinder Not Chocked
11/14/2023
Corrective
Action
501000079179
Large Storage Container Exemptions
11/20/2023
Inspection
Procedure
Type
Designation
Description or Title
Revision or
Date
501000079184
Turbine Deck Fencing Height
11/20/2023
Documents
Resulting from
Inspection
501000079455
LTA Ladder Storage
11/28/2023
Procedures
FPGEN-HSK01
Housekeeping
501000076873
RPV Ref Leg Backfill WGRs Found Detached
09/14/2023
501000076875
WGRs Not Providing Useful Information
09/14/2023
501000077599
WGR Fell Off
10/11/2023
501000077654
WGR Post-SCRAM
10/12/2023
501000077944
WGR/Mount Not Adequate
10/19/2023
501000077945
WGR Broken Gauge
10/19/2023
501000077963
WGR Separated Gauge Housing
10/19/2023
Corrective
Action
Documents
501000078060
WGR Fell Off TC4117B
10/20/2023
Corrective
Action
Documents
Resulting from
Inspection
501000078675
Wireless Gauge Reader Questions from NRC
11/06/2023
Engineering
Changes
601000002574
Specifications of Installation of Cypress
Envirosystems Wireless Gauge Readers
0