Text

SECURITY-RELATED INFORMATION - WITHHOLD UNDER 10 CFR 2.390(d)

UPON REMOVAL OF ENCLOSURE 1 THIS LETTER IS UNCONTROLLED Kim Maza Site Vice President Harris Nuclear Plant 5413 Shearon Harris Road New Hill, NC 27562-9300 984.229.2512 10 CFR 50.4 10 CFR 50.71(e) 10 CFR 50.59(d)

Serial: RA-20-0134 May 15, 2020 ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 Shearon Harris Nuclear Power Plant, Unit 1 Docket No. 50-400 / Renewed License No. NPF-63

Subject:

Submittal of Updated Final Safety Analysis Report (Amendment 63), Technical Specification Bases Revision, Report of Changes Pursuant to 10 CFR 50.59 and Summary of Commitment Changes Ladies and Gentlemen:

Pursuant to 10 CFR 50.71(e), Duke Energy Progress, LLC (Duke Energy), hereby submits Amendment 63 to the Final Safety Analysis Report (FSAR) for the Shearon Harris Nuclear Power Plant, Unit 1 (HNP). In accordance with 10 CFR 50.71(e)(4), this FSAR revision is being submitted within six months following the most recent refueling outage, which concluded on November 18, 2019. The HNP FSAR is included in this submission via two CD-ROMs (Enclosures 1 and 2). Enclosure 1 provides a copy of the FSAR that contains sensitive information to be withheld from public disclosure per 10 CFR 2.390(d)(1). Enclosure 2 provides a copy of the FSAR that has been redacted for public use. Changes made since Amendment 62 are identified by vertical lines in the margins of the pages that are indicated as Amendment 63.

In accordance with 10 CFR 50.59(d)(2), Duke Energy is providing a report summarizing the 10 CFR 50.59 evaluations of changes, tests, and experiments implemented during the period from April 6, 2018 and April 6, 2020 for HNP. This report is included in Enclosure 3.

Pursuant to 10 CFR 50.4 and HNP Technical Specification 6.8.4.n, Technical Specifications (TS) Bases Control Program, Duke Energy is providing the HNP Technical Specification Bases in Enclosure 4. The entire Bases document is being submitted, which includes those changes implemented since the last update provided on November 12, 2018.

This letter also informs the NRC that there have been no unreported changes in commitments made during the period from April 6, 2018, through April 6, 2020.

No new regulatory commitments are contained within this letter.

SECURITY-RELAT ED INFORMATION-W ITHHOLD UNDER 10 CFR 2.390(d)

UPON REMOVAL OF ENCLOSURE 1 THIS LETTER IS UNCONTROLLED U.S. Nuclear Regulatory Commission RA-20-0134 Page 2 If you have any questions regarding this submittal, please contact Art Zaremba, Nuclear Fleet Licensing Manager, at (980) 373-2062 .

I declare under penalty of perjury that the foregoing is true and correct.

Executed on May 15, 2020 .

Sincerely, i<~ [. --)'\I\.) '-

Kim Maza Site Vice President Harris Nuclear Plant

Enclosure:

1. CD-ROM "Harris Nuclear Plant Amendment 63 Submittal" (Non-redacted Version.

Withhold from proactive public release per 10 CFR 2.390(d).)

2. CD-ROM "Harris Nuclear Plant Amendment 63 Submittal, Redacted Version" (This CD may be proactively released to the public. This CD includes redacted versions of FSAR figures identified as sensitive. Documents incorporated by reference that are flagged for redaction are not included. Refer to the tables that follow.)
3. Report of Changes Pursuant to 10 CFR 50.59
4. Shearon Harris Nuclear Power Plant, Unit 1 - Technical Specification Bases cc: J. Zeiler, NRC Sr. Resident Inspector, HNP T. Hood, NRC Project Manager, HNP L. Dudes, NRC Regional Administrator, Region II SECURITY-RELAT ED INFORMATION-W ITHHOLD UNDER 10 CFR 2.390(d)

UPON REMOVAL OF ENCLOSURE 1 THIS LETTER IS UNCONTROLLED

SECURITY-RELATED INFORMATION - WITHHOLD UNDER 10 CFR 2.390(d)

UPON REMOVAL OF ENCLOSURE 1 THIS LETTER IS UNCONTROLLED U.S. Nuclear Regulatory Commission RA-20-0134 Shearon Harris Nuclear Power Plant, Unit 1 Docket No. 50-400 Enclosure 1 CD-ROM Harris Nuclear Plant Amendment 63 Submittal (Non-redacted Version) 1 CD-ROM This CD also contains documents incorporated by reference.

This CD-ROM contains material to be withheld from public release per 10 CFR 2.390(d).

SECURITY-RELATED INFORMATION - WITHHOLD UNDER 10 CFR 2.390(d)

UPON REMOVAL OF ENCLOSURE 1 THIS LETTER IS UNCONTROLLED

U.S. Nuclear Regulatory Commission RA-20-0134 Shearon Harris Nuclear Power Plant, Unit 1 Docket No. 50-400 Enclosure 2 CD-ROM Harris Nuclear Plant Amendment 63 Submittal, Redacted Version 1 CD-ROM This CD also contains documents incorporated by reference not required for redaction.

This CD-ROM may be proactively released to the public.

U.S. Nuclear Regulatory Commission RA-20-0134 Shearon Harris Nuclear Power Plant, Unit 1 Docket No. 50-400 Enclosure 3 Report of Changes Pursuant to 10 CFR 50.59

U.S. Nuclear Regulatory Commission RA-20-0134, Enclosure 3 Page 1 of 6 Summary of 10 CFR 50.59 Evaluations Evaluations performed for changes made in accordance with 10 CFR 50.59 during the time period of April 6, 2018, to April 6, 2020:

Title:

CHRRM TIC Condition - Accept As-Is Documentation Number(s):

Action Request (AR) 02210618 Action Request (AR) 02241749 Brief

Description:

The Containment High Range Radiation Monitors (CHRRMs) were considered inoperable due to an inability to meet a current commitment for monitor accuracy. As documented per NCR 2034217, the CHRRMs are susceptible to impact from a phenomenon known as Temperature Induced Current (TIC). Per Information Notice (IN) 97-45 Supplement 1, a rapid change in temperature can impact the accuracy of the CHRRMs, as the rapid change in temperature can cause a current to develop within the cables providing signal to the CHRRMs, which then impacts the amount of radiation displayed by the CHRRMs. Readings beyond the factor-of-two accuracy requirement can result.

The change adjusted the current description of the CHRRM performance in the Final Safety Analysis Report (FSAR) to include a period of time in which CHRRMs accuracy exceeds factor of two accuracy with the predicted impact of TI). Training in support of the change was provided to ensure adequate site response to a given design basis accident (DBA). The overall function of monitoring the status of fission product barriers (Reactor Coolant System (RCS) and Fuel Cladding) and for detecting and tracking the status of releases into containment during and after a DBA remain. The site meets all Regulatory Guide 1.97 Revision 3 guidance for those variables to be monitored as required for use in determining the magnitude of the release of radioactive materials and continually assessing such releases.

The evaluation demonstrates that prior NRC approval is not required to accept the condition as is, based on the following:

1. None of the described changes alter the site's technical specifications.
2. The proposed activities will not render the CHRRMs unable to support their Emergency Operating Procedure roles. There will be no dose consequences to the public in a Design Basis Event as a result of the proposed activities.
3. The CHRRMs will continue to provide their Post-Accident Monitoring / Regulatory Guide 1.97 functions even with accounting for the impacts of TIC.

U.S. Nuclear Regulatory Commission RA-20-0134, Enclosure 3 Page 2 of 6 Summary of 10 CFR 50.59 Evaluations

Title:

Update to Peak Containment Pressure Documentation Number(s):

Action Request (AR) 02237387 Brief

Description:

Peak containment pressure following a loss of coolant accident (LOCA) is calculated for FSAR Chapter 6 as documented in HNP-M/MECH-1008, the current HNP containment analysis of record (AOR). Peak containment pressure is calculated for two types of reactor coolant system (RCS) breaks: A double-ended pump-suction (DEPS) guillotine break and a double-ended hot-leg (DEHL) guillotine break. In 2011, Westinghouse informed HNP of errors it found within the mass-and-energy (M&E) analysis that is used as input into the HNP containment analysis. The errors involved the timely release of energy stored within the RCS. These errors affected the DEPS analysis with no impact on the DEHL analysis.

After crediting conservatisms in the M&E analysis to limit the analytical impact, Westinghouse performed a simplified hand analysis to estimate a bounding post-blowdown pressure increase.

The CONTEMPT-based containment AOR, owned by Raytheon and performed years earlier for steam generator replacement/power uprate (SGR/PUR), was not re-run. When the calculated increase was added to the post-blowdown peak pressure, the result was a new DEPS peak pressure. This pressure remained bounded by the existing DEHL value and was acceptable.

FSAR Chapter 6 describes the containment analysis and notes that it was performed using the CONTEMPT computer code. The hand analysis performed by Westinghouse for the DEPS case was not based on this code. The Westinghouse calculation represented a potential change in methodology used to verify the containment design function and should be subject to the 50.59 process.

Per NEI 97-07 Section 4.3.8, if a methodology change can be documented as being conservative with respect to the original analysis, then NRC approval is not required. For this reason, calculation HNP-F/NFSA-0353 was created. The purpose of this calculation is to use a GOTHIC analysis to estimate the increase in DEPS peak pressure that would have occurred had the original CONTEMPT code been re-run with the 2005 and 2011 M&E errors corrected.

To do this, HNPF/NFSA-0353 compares two new GOTHIC cases: One thats benchmarked to an original CONTEMPT case and a second in which the M&E input is adjusted to match that supplied by Westinghouse in 2011.

The results of HNP-F/NFSA-0353 showed that the Westinghouse adjustment was conservative with respect to the increase that would have occurred had the original CONTEMPT model been re-run. Therefore, changing the FSAR Table 6.2.1-4 pressure based on the input provided by Westinghouse did not result in a departure from a method of evaluation described in the UFSAR used in establishing the design bases or in the safety analyses. The evaluation also found that the activity did not have any effect on accidents and malfunctions evaluated in licensing basis documents, did not create the potential for a new type of unanalyzed event, and did not have any impact on fission product barriers.

U.S. Nuclear Regulatory Commission RA-20-0134, Enclosure 3 Page 3 of 6 Summary of 10 CFR 50.59 Evaluations

Title:

New Containment LOCA Analysis to Address Westinghouse NSAL-14-2 Documentation Number(s):

Action Request (AR) 02260336 Brief

Description:

Westinghouse NSAL-14-2 describes an error in the specific heat capacity assumed for the steam generator tubes following a loss-of-coolant-accident (LOCA). This error has a non-conservative effect on the Westinghouse mass and energy (M&E) release history for a LOCA which, in turn, impacts the FSAR Chapter 6 containment analysis. Revision 2 of EC 296136 formalizes a new containment LOCA analysis to address NSAL-14-2. The new analysis uses corrected and fully up-to-date M&E input supplied by Westinghouse. The base model for the new containment analysis is documented in HNP-F/NFSA-0308, Revision 0. The new FSAR Chapter 6 containment analysis itself is documented in HNP-F/NFSA-0310, Revision.0. Output from the new containment analysis resulted in changes to plant calculations that serve as the basis for plant design and operation.

The new containment model created in HNP-F/NFSA-0308 and applied in HNP-F/NFSA-0310 uses the GOTHIC 8.2 computer code instead of the CONTEMPT-LT Mod 26 code that was used for the previous analysis of record (AOR), HNP-M/MECH-1008, as described in FSAR Section 6.2.1.1.3.2. The methodology change is evaluated separately under 5EVL 2281660. In addition to calculations, this activity revises design-basis documents (DBDs), equipment qualification data packages (EQDPs), and specifications. This activity does not make any physical changes to the plant and it does not require a change to Technical Specifications.

It was found that the increased long-term plant heat loads resulting from HNP-F/NFSA-0310 Revision 0 may increase reservoir temperatures. All calculated reservoir temperatures for all impacted cases are found to remain less than the design-basis Emergency Service Water (ESW) supply temperature. Thus, even though there may be a small reduction in temperature margin, there will be no impact to the analyzed performance of any safety-related heat exchangers as the assumed ESW inlet temperature remains bounding.

This activity increases the calculated maximum sump and spray pH values. Minimum values are unaffected. The pH values remain within the 7.0 to 11.0 range specified in DBD-106, Technical Specification Basis 3/4.1.2, and FSAR Sections 3.11.5.1, 6.1.1.2, and 6.5.2.1.2. Increases of the magnitudes determined in the EC, combined with the remaining pH margin (pH remains less than 11.0), indicates that there will be no practical or unacceptable change in the amount of corrosion expected inside containment in a post-accident environment.

The long-term temperature and pressure profiles resulting from HNP-F/NFSA-0310 Rev.0 are used as input by several different plant analyses. The new profiles are not fully bounded by the old profiles. The impacts to affected design analyses are acceptable. None of these impacts represent an adverse effect on an FSAR-described design function. This includes containment integrity (a fission-product boundary) for which the peak containment pressure did not change.

For Ultimate Heat Sink Temperature and Containment Sump/Spray pH, it was found that the impact does not represent more than a minimal increase in the likelihood of occurrence of a malfunction of equipment previously evaluated in the FSAR.

U.S. Nuclear Regulatory Commission RA-20-0134, Enclosure 3 Page 4 of 6 Summary of 10 CFR 50.59 Evaluations

Title:

Update to Design Inputs for Spent Fuel Pools Documentation Number(s):

Action Request (AR) 02271155 Brief

Description:

An update to Section 9.1.3.1 of the Shearon Harris Nuclear Power Plant, Unit 1 (HNP), Final Safety Analysis Report (FSAR) has been prepared. This section discusses design inputs for the Spent Fuel Pools (SFPs). Specifically, the change pertains to the discussion of the method for calculating the thermal energy of the fuel in the SFP. This activity was required to account for a change in the software used to calculate the thermal energy of the fuel in SFP, from ORIGEN2 to ORIGEN-ARP and SAS2/ORIGEN-S.

ORIGEN2 had been used previously to determine the heat load, but was no longer supported by the industry. SAS2 is a code sequence designed to calculate, among other things, problem-dependent cross sections. The burnup and decay analysis is then performed by ORIGEN-ARP and ORIGEN-S. These codes were used to determine the thermal energy to be removed by the SFP cooling system.

In reviewing other industry submittals, it was found that the NRC staff had previously concluded in a Safety Evaluation (SE) for Energy Northwest that ...ORIGEN-ARP provides an acceptable means to calculate decay heat loads in the SFP.... No constraints or restrictions were noted in the associated SE. Further, since ORIGEN-ARP calls ORIGEN-S, it is implied that the NRC also approves the use of ORIGEN-S for calculating decay heat as well.

The ORIGEN methodology (ORIGEN-ARP and SAS2/ORIGEN-S) is used by Energy Northwest to determine the thermal energy of the spent fuel in the spent fuel pool. Duke Energy will use the ORIGEN methodology (ORIGEN-ARP and SAS2/ORIGEN-S) in a manner consistent with how Energy Northwest uses the software. Since no constraints or restrictions were noted for Energy Northwest, it follows that the SER provided to Energy Northwest is applicable for the similar use by Duke Energy.

Since this update only involves a change to a method of evaluation, the remainder of the criterion were determined to be not impacted.

U.S. Nuclear Regulatory Commission RA-20-0134, Enclosure 3 Page 5 of 6 Summary of 10 CFR 50.59 Evaluations

Title:

LOCADOSE Computer Code Documentation Number(s):

Action Request (AR) 02277036 Brief

Description:

The activity is replacement of the Westinghouse computer code TITAN5 and the Zachry Nuclear Engineering computer code RADTRAD-NAI with the Bechtel computer code LOCADOSE for Alternative Source Terms (AST) analyses of Harris Nuclear Plant (HNP) design basis accidents.

This is a change to a method of evaluation described in the HNP Final Safety Analysis Report (FSAR) and used in the safety analysis. The NRC approved full scope implementation of AST at Catawba Nuclear Station (CNS), McGuire Nuclear Station (MNS), and Oconee Nuclear Station (ONS) based on its review of AST analyses completed with LOCADOSE, and has approved a HNP License Amendment Request (LAR) that utilized LOCADOSE. In addition, the NRC has approved AST licensing submittals utilizing LOCADOSE from several others in the nuclear industry.

The license correspondence associated with NRC approval of implementation of the method of AST at HNP was searched to find that the NRC made no statement restricting AST analyses for HNP specific to use of TITAN5 or RADTRAD-NAI. The license correspondence associated with NRC approvals of implementation of the method of AST for CNS, MNS, and ONS was searched to determine that the Staff wrote no reservations or restrictions concerning the use of LOCADOSE. In reviewing the method of analyses of radiological consequences of design basis accidents, conformance to the regulatory positions for these analyses is the main concern. It was found from the evaluation above that LOCADOSE may be used pursuant to all of these regulatory positions. Accordingly, the Bechtel computer code LOCADOSE can be used in a manner appropriate for the intended application and within the limitations of the applicable SER [associated with the NRC approvals for implementation of the method of AST]. Additional assessments show that the code is written based on sound engineering practice.

Based on this evaluation, it is concluded that replacement of TITAN5 and RADTRAD-NAI with LOCADOSE does not result in a departure from a method of evaluation described in the HNP FSAR used in establishing the design bases or in the safety analyses.

U.S. Nuclear Regulatory Commission RA-20-0134, Enclosure 3 Page 6 of 6 Summary of 10 CFR 50.59 Evaluations

Title:

New Computer Code for Peak Pressure Analysis Documentation Number(s):

Action Request (AR) 02281660 Brief

Description:

As noted previously for AR 02260336, this particular evaluation is focused on the departure in methodology due to the use of computer code GOTHIC version 8.2 in place of the Ebasco-modified version of CONTEMPT-LT Mod 26 (CONTEMPT) to generate the containment peak pressure analysis in Section 6.2.1 of the HNP FSAR. The proposed activity does not require any change to the Harris Technical Specifications since the proposed activity will remain within the current limits.

Section 4.3.8 of NEI 96-07, Guidelines for 10 CFR 50.59 Implementation, explains how licensees can use different methods without first obtaining a license amendment if those methods have been approved by the NRC for the intended application. Use of the GOTHIC code for containment response was approved (for certain dry containment applications) in a Safety Evaluation for Dominions DOM-NAF-3 methodology report, dated August 30, 2006.

The Dominion methodology is generically applicable to the temperature and pressure response of large, dry Containments. This is consistent with the Containment design at HNP and consistent with the scope of HNP FSAR Section 6.2.1. A detailed comparison of the HNP GOTHIC model to the current methodology ensured that all elements of the methodology which are used within the proposed activity have been applied. In using GOTHIC Version 8.2 as the most recent version of the GOTHIC computer code, the differences relative to version 7.2 have been evaluated and addressed. This evaluation showed that the only differences between the two GOTHIC code versions were small variations largely due to the revised modeling treatment of droplet fields in GOTHIC Version 8.2. Internal procedures are in place for software quality assurance, verification, and validation of the code and the input data, as well as input file organization.

There are no conflicts between the proposed activity and the Harris licensing basis. The GOTHIC calculations have been performed under Dukes QA program (including computer code installation) and qualified through benchmark comparisons to previous CONTEMPT calculations for HNP. The determination and justification are consistent with Example 4 presented in Section 4.3.8.3 of NEI 96-07, Revision 1, Guidelines for 10 CFR 50.59 Implementation. This change to the methodology described in the FSAR to another method is documented as a change using 10 CFR 50.59(a)(2)(ii) of the departure definition (replacing the methodology in whole rather than any individual elements), with the definition from 10 CFR 50.59(a)(2)(i) not used for this change. This adheres to guidance given by the NRC in Section C.1.a of Regulatory Guide 1.187, Revision 1, Guidance for Implementation of 10 CFR 50.59, Changes, Tests, and Experiments.

This conclusion is not contingent on any unverified assumptions and this evaluation does not contain any commitments for future actions or specifies conditions which must be maintained to insure acceptability. Based on the above, the proposed changes do not depart from a method of evaluation described in the FSAR.

U.S. Nuclear Regulatory Commission RA-20-0134, Enclosure 4 Shearon Harris Nuclear Power Plant, Unit 1 Docket No. 50-400 Enclosure 4 Shearon Harris Nuclear Power Plant, Unit 1 - Technical Specification Bases

BASES FOR SECTION 2.0 SAFETY LIMITS AND LIMITING SAFETY SYSTEM SETTINGS

NOTE The BASES contained in succeeding pages summarize the reasons for the Specifications in Section 2.0, but in accordance with 10 CFR 50.36 are not part of these Technical Specifications.

2.1 SAFETY LIMITS BASES 2.1.1 REACTOR CORE The restrictions of this safety limit prevent overheating of the fuel and possible cladding perforation which would result in the release of fission products to the reactor coolant.

Overheating of the fuel cladding is prevented by restricting fuel operation to within the nucleate boiling regime where the heat transfer coefficient is large and the cladding surface temperature is slightly above the coolant saturation temperature.

Operation above the upper boundary of the nucleate boiling regime could result in excessive cladding temperatures because of the onset of departure from nucleate boiling (DNB) and the resultant sharp reduction in heat transfer coefficient. DNB is not a directly measurable parameter during operation and therefore THERMAL POWER and Reactor Coolant Temperature and Pressure have been related to DNB. This relation has been developed to predict the DNB flux and the location of DNB for axially uniform and nonuniform heat flux distributions. The local DNB heat flux ratio (DNBR) defined as the ratio of the heat flux that would cause DNB at a particular core location to the local heat flux is indicative of the margin to DNB. The DNBR safety limit for high thermal performance fuel is 1.141 for the Siemens HTP correlation (Reference 1).

The restrictions of this safety limit also prevent fuel centerline melting. Fuel centerline melting occurs when the local LHR, or power peaking, in a region of the fuel is high enough to cause the fuel centerline temperature to reach the melting point of the fuel. Expansion of the pellet upon centerline melting may cause the pellet to stress the cladding to the point of failure, allowing an uncontrolled release of activity to the reactor coolant. Reference 2 describes the methodology for determining fuel melt limits. The COPERNIC Methodology replaces the RODEX Methodology for determining Technical Specification safety limits (COLR limits).

SHEARON HARRIS - UNIT 1 B 2-1 Amendment No. 171

2.1 SAFETY LIMITS BASES 2.1.1 REACTOR CORE (Continued)

The safety limit figure provide in the COLR shows the loci of points of Fraction of Rated Thermal power, RCS Pressure, and average temperature for which the minimum DNBR is not less than the safety analyses limit, that fuel centerline temperature remains below melting, that the average enthalpy in the hot leg is less than or equal to the enthalpy of saturated liquid, and that the exit quality is within the limits defined by the DNBR correlation. The reactor core safety limits are established to preclude violation of the following fuel design criteria:

a. There must be at least 95% probability at a 95% confidence level (the 95 / 95 DNB criteria) that the hot fuel rod in the core does not experience DNB; and
b. There must be at least a 95% probability at a 95% confidence level that the hot fuel pellet in the core does not experience centerline fuel melting.

The reactor core safety limits are used to define the various RPS functions such that the above criteria are satisfied during steady state operation and Condition I and II events. To ensure that the RPS precludes the violation of the above criteria, additional criteria are applied to the Over Temperature and Overpower T reactor trip functions. That is, it must be demonstrated that the average enthalpy in the hot leg is less than or equal to the saturation enthalpy and that the core exit quality is within the limits defined by the DNBR correlation. Appropriate functioning of the RPS ensures that for variations in the THERMAL POWER, RCS Pressure, RCS average temperature, RCS flow rate, and I that the reactor core safety limits will be satisfied during steady state operation and Condition I and II events.

SHEARON HARRIS - UNIT 1 B 2-1a Amendment No. 161

SAFETY LIMITS BASES 2.1.2 REACTOR COOLANT SYSTEM PRESSURE The restriction of this Safety Limit protects the integrity of the Reactor Coolant System (RCS) from overpressurization and thereby prevents the release of radionuclides contained in the reactor coolant from reaching the containment atmosphere.

The reactor pressure vessel, pressurizer, and the RCS piping, pumps, valves and fittings are designed to Section Ill, Division I of the ASME Code for Nuclear Power Plants, which permits a maximum transient pressure of 110% to 125% of design pressure (2485 psig) depending on component. The Safety Limit of 2735 psig (11 0% of design pressure) is therefore consistent with the design criteria and associated Code requirements.

The entire RCS is hydrotested at 125% (31 07 psig) of design pressure, to demonstrate integrity prior to initial operation.

2.2 LIMITING SAFETY SYSTEM SETTINGS 2.2.1 REACTOR TRIP SYSTEM INSTRUMENTATION SETPOINTS The Reactor Trip Setpoint Limits specified in Table 2.2-1 are the nominal values at which the Reactor trips are set for each functional unit. The Trip Setpoints have been selected to ensure that the core and Reactor Coolant System are prevented from exceeding their Safety Limits during normal operation and design basis anticipated operational occurrences and to assist the Engineered Safety Features Actuation System in mitigating the consequences of accidents. The Setpoint for a Reactor Trip System or interlock function is considered to be adjusted consistent with the nominal value when the "as measured" Setpoint is within the band allowed for calibration accuracy. For example, if a bistable has a trip setpoint of 100%, a span of 125%, and a calibration accuracy of 0.5% of span, then the bistable is considered to be adjusted to the trip setpoint as long as the "as measured" value for the bistable is :::; 100.62%.

To accommodate the instrument drift assumed to occur between operational tests and the accuracy to which Setpoints can be measured and calibrated, Allowable Values for the Reactor Trip Setpoints have been specified in Table 2.2-1. Operation with Setpoints less conservative than the Trip Setpoint but within the Allowable Value is acceptable since an allowance has been made in the safety analysis to accommodate this error. An optional provision has been included for determining the OPERABILITY of a channel when its Trip Setpoint is found to exceed the Allowable Value. The methodology of this option utilizes the "as measured" deviation from the specified calibration point for rack and sensor components in conjunction with a statistical combination of the other uncertainties of the instrumentation to measure the process variable and the uncertainties in calibrating the instrumentation. In Equation 2.2-1, Z + R + S :::; TA, the interactive effects of the errors in the rack and the sensor, and the "as measured" values of the errors are considered. Z, as specified in Table 2.2-1, in percent span, is the statistical summation of SHEARON HARRIS - UNIT 1 B 2-2

LIMITING SAFETY SYSTEM SETTINGS BASES REACTOR TRIP SYSTEM INSTRUMENTATION SETPOINTS (Continued) errors assumed in the analysis excluding those associated with the sensor and rack drift and the accuracy of their measurement. TA or Total Allowance is the difference, in percent span, between the Trip Setpoint and the value used in the analysis for Reactor trip. R or Rack Error is the "as measured" deviation, in percent span, for the affected channel from the specified Trip Setpoint. S or Sensor Error is either the "as measured" deviation of the sensor from its calibration point or the value specified in Table 2.2-1, in percent span, from the analysis assumptions. Use of Equation 2.2-1 allows for a sensor drift factor and an increased rack drift factor, and provides a threshold value for determination of OPERABILITY.

The methodology to derive the Trip Setpoints is based upon combining all of the uncertainties in the channels. Inherent to the determination of the Trip Setpoints are the magnitudes of these channel uncertainties. Sensors and other instrumentation utilized in these channels are expected to be capable of operating within the allowances of these uncertainty magnitudes.

Rack drift in excess of the Allowable Value exhibits the behavior that the rack has not met its allowance. Being that there is a small statistical chance that this will happen, an infrequent excessive drift is expected. Rack or sensor drift, in excess of the allowance that is more than occasional, may be indicative of more serious problems and should warrant further investigation.

The statistical core design (SCD) methodology presented in DPC-NE-2005 statistically combines the effects of initial condition uncertainty and other uncertainties on DNB to determine a DNBR statistical design limit (SDL). The SDL is set such that there is a 95 percent probability with 95 percent confidence that DNB will not occur when the calculated minimum DNBR is at the DNBR limit, accounting for uncertainty. The initial condition uncertainty contained in the SDL comprises some or all of the channel uncertainty for some reactor trip functions. The Total Allowances given in Table 2.2-1 satisfy Equation 2.2-1, accounting for all channel uncertainty. FSAR Chapter 15 analyses performed using the SCD methodology account for some or all of the channel uncertainty in the SDL. As such, the RPS trip setpoints used in SCD analyses may assume a smaller Total Allowance which satisfies Equation 2.2-1 after removal of uncertainty terms accounted for in the SDL.

The various Reactor trip circuits automatically open the Reactor trip breakers whenever a condition monitored by the Reactor Trip System reaches a preset or calculated level. In addition to redundant channels and trains, the design approach provides a Reactor Trip System which monitors numerous system variables, therefore providing Trip System functional diversity. The functional capability at the specified trip setting is required for those anticipatory or diverse Reactor trips for which no direct credit was assumed in the safety analysis to enhance the overall reliability of the Reactor Trip System. The Reactor Trip System initiates a Turbine trip signal whenever Reactor trip is initiated. This prevents the reactivity insertion that would otherwise result from excessive Reactor Coolant System cooldown and thus avoids unnecessary actuation of the Engineered Safety Features Actuation System.

Reactor Trip System Instrumentation Setpoints and TSTF-493 This section applies only to the Functional Units to which Notes 7 and 8 in the Trip Setpoint Column are applicable. Those Functional Units have revisions in accordance with Technical Specification Task Force Traveler 493 (TSTF-493). Clarify Application of Setpoint Methodology for LSSS Functions. Those Functional Units are limited to

  • Power Range, Neutron Flux High Setpoint
  • Power Range, Neutron Flux Low Setpoint
  • Power Range, Neutron Flux High Positive Rate SHEARON HARRIS - UNIT 1 B 2-3 Amendment No. 175

LIMITING SAFETY SYSTEM SETTINGS BASES REACTOR TRIP SYSTEM INSTRUMENTATION SETPOINTS (Continued)

  • Pressurizer Water Level - High Setpoint
  • Reactor Coolant Flow - Low Setpoint Notes 7 and 8 have been added to Table 2.2-1 that require verifying both trip setpoint setting as-found and as-left values during surveillance testing. In accordance with 10 CFR 50.36, these functions are Limiting Safety System Settings. Adding test requirements ensures that instruments will function as required to initiate protective systems or actuate mitigating systems at the point assumed in the applicable safety analysis. These notes address NRC staff concerns with Technical Specification Allowable Values. Specifically, calculated Allowable Values may be non-conservative depending upon the evaluation of instrument performance history, and the as-left requirements of the calibration procedures could have an adverse effect on equipment operability.

In addition, using Allowable Values as the limiting setting for assessing instrument channel operability may not be fully in compliance with the intent of 10 CFR 50.36, and the existing surveillance requirements would not provide adequate assurance that instruments will always actuate safety functions at the point assumed in the applicable safety analysis. In the Harris Technical Specifications, the term Trip Setpoint is analogous to Nominal Trip Setpoint (NTSP) in TSTF-493.

Note 7 requires a channel performance evaluation when the as-found setting is outside its as-found tolerance. The performance evaluation verifies that the channel will continue to behave in accordance with safety analysis and instrument performance assumptions in the setpoint methodology. The purpose of this evaluation is to provide confidence in the performance prior to returning the channel to service. If the as-found setting is non-conservative with respect to the Allowable Value, the channel is INOPERABLE. If the as-found setting is conservative with respect to the Allowable Value but is outside the as-found tolerance band, the channel is OPERABLE but degraded. The degraded channel condition will be further evaluated during performance of the surveillance. This evaluation will consist of resetting the channel setpoint to within the as-left tolerances applicable to the actual setpoint implemented in the surveillance procedures (field setting), and evaluating the channel response. If the channel is functioning as required and is expected to pass the next surveillance, then the channel is OPERABLE and can be restored to service at the completion of the surveillance. After the surveillance is completed, the channel as-found condition is entered into the corrective action program for further analysis and trending.

Note 8 requires that the as-left channel setting be reset to a value that is within the as-left tolerances about the Trip Setpoint in Table 2.2-1 or within as-left tolerances about a more conservative actual (field) setpoint. As-left channel settings outside the as-left tolerances of PLP-106 and the surveillance procedures cause the channel to be INOPERABLE.

A tolerance is necessary because no device perfectly measures the process. Additionally, it is not possible to read and adjust a setting to an absolute value due to the readability and/or accuracy of the test instruments or the ability to adjust potentiometers. The as-left tolerance is considered in the setpoint calculation. Failure to set the actual plant trip setpoint to within as-left the tolerances of the NTSP or within as-left tolerances of a more conservative actual field setpoint would invalidate the assumptions in the setpoint calculation, because any subsequent instrument drift would not start from the expected as-left setpoint. The determination will consider whether the instrument is degraded or is capable of being reset and performing its specified safety function. If the channel is determined to be functioning as required (i.e., the channel can be adjusted to within the as-left tolerance and is determined to be functioning normally based on the determination performed prior to returning the channel to service), then the channel is OPERABLE and can be restored to service.

SHEARON HARRIS - UNIT 1 B 2-3a Amendment No. 175

LIMITING SAFETY SYSTEM SETTINGS BASES REACTOR TRIP SYSTEM INSTRUMENTATION SETPOINTS (Continued)

If the as-left instrument setting cannot be returned to a setting within the prescribed as-left tolerance band, the instrument would be declared INOPERABLE.

The methodologies for calculating the as-found tolerances and as-left tolerances about the Trip Setpoint or more conservative actual field setpoint are specified in EGR-NGGC-0153, Engineering Instrument Setpoints, which is incorporated by reference into the FSAR. The actual field setpoint and the associated as-found and as-left tolerances are specified in PLP-106, the applicable section of which is incorporated by reference into the FSAR.

Limiting Trip Setpoint (LTSP) is generic terminology for the setpoint value calculated by means of the setpoint methodology documented in EGR-NGGC-0153. HNP uses the plant-specific term Nominal Trip Setpoint (NTSP) in place of the generic term LTSP. The NTSP is the LTSP with margin added, and is always equal to or more conservative than the LTSP. The NTSP may use a setting value that is more conservative than the LTSP, but for Technical Specification compliance with 10 CFR 50.36, the plant-specific setpoint term NTSP is cited in Note 8.

The NTSP meets the definition of a Limiting Safety System Setting per 10 CFR 50.36 and is a predetermined setting for a protective channel chosen to ensure that automatic protective actions will prevent exceeding Safety Limits during normal operation and design basis anticipated operational occurrences, and assist the Engineered Safety Features Actuation System in mitigating the consequences of accidents. The Allowable Value is the least conservative value of the as-found setpoint that the channel can have when tested, such that a channel is OPERABLE if the as-found setpoint is within the as-found tolerance and is conservative with respect to the Allowable Value during a CHANNEL CALIBRATION or CHANNEL OPERATIONAL TEST. As such, the Allowable Value differs from the NTSP by an amount greater than or equal to the expected instrument channel uncertainties, such as drift, during the surveillance interval.

In this manner, the actual NTSP setting ensures that a Safety Limit is not exceeded at any given point of time as long as the channel has not drifted beyond expected tolerances during the surveillance interval. Although the channel is OPERABLE under these circumstances, the trip setpoint must be left adjusted to a value within the as-left tolerance band, in accordance with uncertainty assumptions stated in the setpoint methodology (as-left criteria), and confirmed to be operating within the statistical allowances of the uncertainty terms assigned (as-found criteria).

Field setting is the term used for the actual setpoint implemented in the plant surveillance procedures, where margin has been added to the calculated field setting. The as-found and as-left tolerances apply to the field settings implemented in the surveillance procedures to confirm channel performance. A trip setpoint may be set more conservative than the NTSP as necessary in response to plant conditions. However, in this case, the instrument operability must be verified based on the field setting and not the NTSP.

Manual Reactor Trip The Reactor Trip System includes manual Reactor trip capability.

Power Range, Neutron Flux In each of the Power Range Neutron Flux channels there are two independent bistables, each with its own trip setting used for a High and Low Range trip setting. The Low Setpoint trip provides protection during subcritical and low power operations to mitigate the consequences of a power excursion beginning from low power, and the High Setpoint trip provides protection during power operations to mitigate the consequences of a reactivity excursion from all power levels.

The Low Setpoint trip may be manually blocked above P-10 (a power level of approximately 10%

of RATED THERMAL POWER) and is automatically reinstated below the P-10 Setpoint.

SHEARON HARRIS - UNIT 1 B 2-3b Amendment No. 175

LIMITING SAFETY SYSTEM SETTINGS BASES REACTOR TRIP SYSTEM INSTRUMENTATION SETPOINTS (Continued)

Power Range, Neutron Flux, High Positive Rate The Power Range Positive Rate trip provides protection against rapid flux increases which are characteristic of a rupture of a control rod drive housing. Specifically, this trip complements the Power Range Neutron Flux High and Low trips to ensure that the criteria are met for rod ejection from mid power.

Intermediate and Source Range, Neutron Flux The Intermediate and Source Range, Neutron Flux trips provide core protection during reactor startup to mitigate the consequences of an uncontrolled rod cluster control assembly bank withdrawal from a subcritical condition. These trips provide redundant protection to the Low Setpoint trip of the Power Range, Neutron Flux channels. The Source Range channels will initiate a Reactor trip at about 105 counts per second unless manually blocked when P-6 becomes active. The Intermediate Range channels will initiate a Reactor trip at a current level equivalent to approximately 25% of RATED THERMAL POWER unless manually blocked when P-10 becomes active.

Overtemperature T The Overtemperature T trip provides core protection to prevent DNB for all combinations of pressure, power, coolant temperature, and axial power distribution, provided that the transient is slow with respect to transport to and response time of the temperature detectors (about 4 seconds), and pressure is within the range between the Pressurizer High and Low Pressure trips.

The Setpoint is automatically varied with: (1) coolant temperature to correct for temperature induced changes in density and heat capacity of water and includes dynamic compensation for transport to and response time of the loop temperature detectors, (2) pressurizer pressure, and (3) axial power distribution. With normal axial power distribution, this Reactor trip limit is always below the core Safety Limit as shown in the COLR. If axial peaks are greater than design, as indicated by the difference between top and bottom power range nuclear detectors, the Reactor trip is automatically reduced according to the notations in Table 2.2-1.

SHEARON HARRIS - UNIT 1 B 2-4 Amendment No. 175

LIMITING SAFETY SYSTEM SETTINGS BASES REACTOR TRIP SYSTEM INSTRUMENTATION SETPOINTS (Continued)

Overpower T The Overpower T trip provides assurance of fuel integrity (e.g., no fuel pellet melting and less than 1% cladding strain) under all possible overpower conditions, limits the required range for Overtemperature T trip, and provides a backup to the High Neutron Flux trip. The Setpoint is automatically varied with: (1) coolant temperature to correct for temperature induced changes in density and heat capacity of water, (2) rate of change of temperature for dynamic compensation for transport to and response time of the loop temperature detectors, and (3) axial power distribution, to ensure that the allowable heat generation rate (kW/ft) is not exceeded. If axial peaks are greater than design, as indicated by the difference between top and bottom power range nuclear detectors, the Reactor trip is automatically reduced according to the notations in Table 2.2-1.

Pressurizer Pressure In each of the pressurizer pressure channels, there are two independent bistables, each with its own trip setting to provide for a High and Low Pressure trip thus limiting the pressure range in which reactor operation is permitted. The Low Setpoint trip protects against low pressure which could lead to DNB by tripping the reactor in the event of a loss of reactor coolant pressure.

On decreasing power the Low Setpoint trip is automatically blocked by the loss of P-7 (a power level of approximately 10% of RATED THERMAL POWER or turbine inlet pressure at approximately 10% of full power equivalent); and on increasing power, automatically reinstated by P-7.

The High Setpoint trip functions in conjunction with the pressurizer relief and safety valves to protect the Reactor Coolant System against system overpressure.

Pressurizer Water Level The Pressurizer High Water Level trip is provided to prevent water relief through the pressurizer safety valves. On decreasing power the Pressurizer High Water Level trip is automatically blocked by the loss of P-7 (a power level of approximately 10% of RATED THERMAL POWER or a turbine inlet pressure at approximately 10% of full power equivalent); and on increasing power, automatically reinstated by P-7.

Reactor Coolant Flow The Reactor Coolant Low Flow trips provide core protection to prevent DNB by mitigating the consequences of a loss of flow resulting from the loss of one or more reactor coolant pumps.

On increasing power above P-7 (a power level of approximately 10% of RATED THERMAL POWER or a turbine inlet pressure at approximately 10% of full power equivalent), an automatic Reactor trip will occur if the flow in more than one loop drops below 91.7% of nominal full loop flow. Above P-8 (a power level of approximately 49% of RATED THERMAL POWER) an automatic Reactor trip will occur if the flow in any single loop drops below 91.7% of nominal full loop flow. Conversely, on decreasing power between P-8 and P-7, an automatic Reactor trip will occur on low reactor coolant flow in more than one loop; and below P-7, the trip function is automatically blocked.

SHEARON HARRIS - UNIT 1 B 2-5 Amendment No. 175

LIMITING SAFETY SYSTEM SETTINGS BASES REACTOR TRIP SYSTEM INSTRUMENTATION SETPOINTS (Continued)

Steam Generator Water Level The Steam Generator Water Level Low-Low trip protects the reactor from loss of heat sink in the event of a sustained steam/feedwater flow mismatch resulting from loss of normal feedwater.

The specified Setpoint provides allowances for starting delays of the Auxiliary Feedwater System.

Steam/Feedwater Flow Mismatch and Low Steam Generator Water Level The Steam/Feedwater Flow Mismatch in coincidence with a Steam Generator Low Water Level trip is not used in the transient and accident analyses but is included in Table 2.2-1 to ensure the functional capability of the specified trip settings and thereby enhance the overall reliability of the Reactor Trip System. This trip is redundant to the Steam Generator Water Level Low-Low trip.

The Steam/Feedwater Flow Mismatch portion of this trip is activated when the steam flow exceeds the feedwater flow by the setpoint value. The Steam Generator Low Water level portion of the trip is activated when the setpoint value is reached, as indicated by the narrow range instrument. These trip values include sufficient allowance in excess of normal operating values to preclude spurious trips but will initiate a Reactor trip before the steam generators are dry.

Therefore, the required capacity and starting time requirements of the auxiliary feedwater pumps are reduced and the resulting thermal transient on the Reactor Coolant System and steam generators is minimized.

Undervoltage and Underfrequency - Reactor Coolant Pump Buses The Undervoltage and Underfrequency Reactor Coolant Pump Bus trips provide core protection against DNB as a result of complete loss of forced coolant flow. The specified Setpoints assure a Reactor trip signal is generated before the Low Flow Trip Setpoint is reached. Time delays are incorporated in the Underfrequency and Undervoltage trips to prevent spurious Reactor trips from momentary electrical power transients.

On decreasing power the Undervoltage and Underfrequency Reactor Coolant Pump Bus trips are automatically blocked by the loss of P-7 (a power level of approximately 10% of RATED THERMAL POWER or a turbine inlet pressure at approximately 10% of full power equivalent);

and on increasing power, reinstated automatically by P-7.

SHEARON HARRIS - UNIT 1 B 2-6 Amendment No. 175

LIMITING SAFETY SYSTEM SETTINGS BASES REACTOR TRIP SYSTEM INSTRUMENTATION SETPOINTS (Continued)

Turbine Trip A Turbine trip initiates a Reactor trip. On decreasing power the Reactor trip from the Turbine trip is automatically blocked by the loss of P-7 (a power level of approximately 10% of RATED THERMAL POWER or a turbine inlet pressure at approximately 10% of full power equivalent);

and on increasing power, reinstated automatically by P-7.

Safety Injection Input from ESF If a Reactor trip has not already been generated by the Reactor Trip System instrumentation, the ESF automatic actuation logic channels will initiate a Reactor trip upon any signal which initiates a Safety Injection. The ESF instrumentation channels which initiate a Safety Injection signal are shown in Table 3.3-3.

Reactor Trip System Interlocks The Reactor Trip System interlocks perform the following functions:

P-6 On increasing power P-6 allows the manual block of the Source Range trip (i.e.,

prevents premature block of Source Range trip), and deenergizes the high voltage to the detectors. On decreasing power, Source Range Level trips are automatically reactivated and high voltage restored.

P-7 On increasing power P-7 automatically enables Reactor trips on low flow in more than one reactor coolant loop, reactor coolant pump motor undervoltage and underfrequency, turbine trip, pressurizer low pressure and pressurizer high level.

On decreasing power, the above listed trips are automatically blocked.

P-8 On increasing power, P-8 automatically enables Reactor trips on low flow in one or more reactor coolant loops. On decreasing power, the P-8 automatically blocks the above listed trips.

P-10 On increasing power, P-10 allows the manual block of the Intermediate Range trip and the Low Setpoint Power Range trip; and automatically blocks the Source Range trip and deenergizes the Source Range high voltage power. On decreasing power, the Intermediate Range trip and the Low Setpoint Power Range trip are automatically reactivated. Provides input to P-7.

P-13 Provides input to P-7.

References

1. EMF-92-153(P)(A), "HTP: Departure from Nucleate Boiling Correlation for High Thermal Performance Fuel."
2. BAW-10231P-A, Revision 1, COPERNIC Fuel Rod Design Computer Code.

SHEARON HARRIS - UNIT 1 B 2-7 Amendment No. 171

BASES FOR SECTIONS 3.0 AND 4.0 LIMITING CONDITIONS FOR OPERATION AND SURVEILLANCE REQUIREMENTS

The BASES contained in succeeding pages summarize the reasons for the Specifications in Sections 3.0 and 4.0, but in accordance with 10 CFR 50.36 are not part of these Technical Specifications.

3/4.0 APPLICABILITY BASES The specifications of this section provide the general requirements applicable to each of the Limiting Conditions for Operation and Surveillance Requirements within Section 3/4. In the event of a disagreement between the requirements stated in these Technical Specifications and those stated in an applicable Federal Regulation or Act, the requirements stated in the applicable Federal Regulation or Act shall take precedence and shall be met. SR 4.0.2 and SR 4.0.3 apply in Chapter 6 only when invoked by a Chapter 6 Specification.

3.0.1 This specification defines the applicability of each specification in terms of defined OPERATIONAL MODES or other specified conditions and is provided to delineate specifically when each specification is applicable.

3.0.2 This specification defines those conditions necessary to constitute compliance with the terms of an individual Limiting Condition for Operation and associated ACTION requirement.

3.0.3 The specification delineates the measures to be taken for those circumstances not directly provided for in the ACTION statements and whose occurrence would violate the intent of a specification. For example, Specification 3.5.2 requires two independent ECCS subsystems to be OPERABLE and provides explicit ACTION requirements if one ECCS subsystem is inoperable. Under the requirements of Specification 3.0.3, if both the required ECCS subsystems are inoperable, within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> measures must be initiated to place the unit in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />, and in at least HOT SHUTDOWN within the following 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />. As a further example, Specification 3.6.2.1 requires two Containment Spray Systems to be OPERABLE and provides explicit ACTION requirements if one Spray System is inoperable. Under the requirements of Specification 3.0.3, if both the required Containment Spray Systems are inoperable, within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> measures must be initiated to place the unit in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />, in at least HOT SHUTDOWN within the following 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />, and in COLD SHUTDOWN within the subsequent 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />. It is acceptable to initiate and complete a reduction in OPERATIONAL MODES in a shorter time interval than required in the ACTION statement and to add the unused portion of this allowable out-of-service time to that provided for operation in subsequent lower OPERATION MODE(S). Stated allowable out-of-service times are applicable regardless of the OPERATIONAL MODE(S) in which the inoperability is discovered but the times provided for achieving a mode reduction are not applicable if the inoperability is discovered in a mode lower than the applicable mode. For example if the Containment Spray System was discovered to be inoperable while in STARTUP, the ACTION Statement would allow up to 156 hours0.00181 days <br />0.0433 hours <br />2.579365e-4 weeks <br />5.9358e-5 months <br /> to achieve COLD SHUTDOWN. If HOT STANDBY is attained in 16 hours1.851852e-4 days <br />0.00444 hours <br />2.645503e-5 weeks <br />6.088e-6 months <br /> rather than the allowed 78 hours9.027778e-4 days <br />0.0217 hours <br />1.289683e-4 weeks <br />2.9679e-5 months <br />, 140 hours0.00162 days <br />0.0389 hours <br />2.314815e-4 weeks <br />5.327e-5 months <br /> would still be available before the plant would be required to be in COLD SHUTDOWN. However, if this system was discovered to be inoperable while in HOT STANDBY, the 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> provided to achieve HOT STANDBY would not be additive to the time available to achieve COLD SHUTDOWN so that the total allowable time is reduced from 156 hours0.00181 days <br />0.0433 hours <br />2.579365e-4 weeks <br />5.9358e-5 months <br /> to 150 hours0.00174 days <br />0.0417 hours <br />2.480159e-4 weeks <br />5.7075e-5 months <br />. Planned entry into LCO 3.0.3 should be avoided. If it is not practicable to avoid planned entry into LCO 3.0.3, plant risk should be assessed and managed in accordance with 10 CFR 50.65(a)(4), and the planned entry into LCO 3.0.3 should have less effect on plant safety than other practicable alternatives.

3.0.4 This specification establishes limitations on MODE changes when a Limiting Condition for Operation is not met. It precludes placing the facility in a higher (LCO 3.0.4 is only applicable when entering MODE 4 from MODE 5, MODE 3 from MODE 4, MODE 2 from MODE 3, or MODE 1 from MODE 2) MODE of SHEARON HARRIS - UNIT 1 B 3/4 0-1 Amendment No. 166 Revision 1

APPLICABILITY BASES 3.0.4 (Continued) operation when the requirements for a Limiting Condition for Operation are not met and continued noncompliance to these conditions would result in a shutdown to comply with the ACTION requirements if a change in MODES were permitted. The purpose of this specification is to ensure that facility operation is not initiated or that higher MODES of operation are not entered when corrective action is being taken to obtain compliance with a specification by restoring equipment to OPERABLE status or parameters to specified limits. Compliance with ACTION requirements that permit continued operation of the facility for an unlimited period of time provides an acceptable level of safety for continued operation without regard to the status of the plant before or after a MODE change.

Therefore, in this case, entry into an OPERATIONAL MODE or other specified condition may be made and the ACTION requirements followed after entry into the Applicability.

For example, Specification 3.0.4 may be used when the required ACTION to be entered states that an inoperable instrument channel must be placed in the trip condition within the required time limit. Transition into a MODE or other specified condition in the Applicability may be made in accordance with Specification 3.0.4 and the channel is subsequently placed in the tripped condition within the required time limit, which begins when the Applicability is entered. If the instrument channel cannot be placed in the tripped condition and the subsequent ACTION allows the OPERABLE train to placed in operation, use of Specification 3.0.4 is acceptable because the subsequent ACTIONS to be entered following entry into the MODE include ACTIONS (place the OPERABLE train in operation) that permit safe plant operation for an unlimited period of time in the MODE or other specified condition to be entered.

The provisions of this specification should not, however, be interpreted as endorsing the failure to exercise good practice in restoring systems or components to OPERABLE status before plant startup.

When a shutdown is required to comply with ACTION requirements, the provisions of Specification 3.0.4 do not apply because they would delay placing the facility in a lower MODE of operation.

3.0.5 This specification establishes the allowance for restoring equipment to service under administrative controls when it has been removed from service or declared inoperable to comply with ACTIONS. The sole purpose of this Specification is to provide an exception to 3.0.1 (e.g., to not comply with the applicable Required Action(s)) to allow the performance of required testing to demonstrate:

a. The OPERABILITY of the equipment being returned to service; or
b. The OPERABILITY of other equipment The administrative controls ensure the time the equipment is returned to service in conflict with the requirements of the ACTIONS is limited to the time absolutely necessary to perform the required testing to demonstrate OPERABILITY. This Specification does not provide time to perform any other preventive or corrective maintenance. Specification 3.0.5 should not be used in lieu of other practicable alternatives that comply with Required Actions and that do not require changing the MODE or other specified conditions in the Applicability in order to demonstrate equipment is OPERABLE. Specification 3.0.5 is not intended to be used repeatedly.

An example of demonstrating equipment is OPERABLE with the Required Actions not met is opening a manual valve that was closed to comply with Required Actions to isolate a flowpath with excessive Reactor Coolant System (RCS) Pressure Isolation Valve (PIV)

SHEARON HARRIS - UNIT 1 B 3/4 0-2 Amendment No. 162

APPLICABILITY BASES 3.0.5 (Continued) leakage in order to perform testing to demonstrate that RCS PIV leakage is now within limit.

Examples of demonstrating equipment OPERABILITY include instances in which it is necessary to take an inoperable channel or trip system out of a tripped condition that was directed by a Required Action, if there is no Required Action Note for this purpose. An example of verifying OPERABILITY of equipment removed from service is taking a tripped channel out of the tripped condition to permit the logic to function and indicate the appropriate response during performance of required testing on the inoperable channel.

Examples of demonstrating the OPERABILITY of other equipment are taking an inoperable channel or trip system out of the tripped condition 1 ) to prevent the trip function from occurring during the performance of required testing on another channel in the other trip system, or 2) to permit the logic to function and indicate the appropriate response during the performance of required testing on another channel in the same trip system.

The administrative controls in Specification 3.0.5 apply in all cases to systems or components in Section 3 of the Technical Specifications, as long as the testing could not be conducted while complying with the Required Actions. This includes the realignment or repositioning of redundant or alternate equipment or trains previously manipulated to comply with ACTIONS, as well as equipment removed from service or declared inoperable to comply with ACTIONS.

3.0.6 3.0.6 establishes conditions under which systems described in the Technical Specifications are considered to remain OPERABLE when required barriers are not capable of providing their related support function(s).

Barriers are doors, walls, floor plugs, curbs, hatches, installed structures or components, or other devices, not explicitly described in Technical Specifications, that support the performance of the safety function of systems described in the Technical Specifications.

This LCO states that the supported system is not considered to be inoperable solely due to required barriers not capable of performing their related support function(s) under the described conditions. LCO 3.0.6 allows 30 days before declaring the supported system(s) inoperable and the LCO(s) associated with the supported system(s) not met. A maximum time is placed on each use of this allowance to ensure that as required barriers are found or are otherwise made unavailable, they are restored. However, the allowable duration may be less than the specified maximum time based on the risk assessment.

If the allowed time expires and the barriers are unable to perform their related support function(s), the supported systems LCO(s) must be declared not met and the Conditions and Required Actions entered in accordance with 3.0.1.

This provision does not apply to barriers which support ventilation systems or to fire barriers. The Technical Specifications for ventilation systems provide specific Conditions for inoperable barriers. Fire barriers are addressed by other regulatory requirements and associated plant programs. This provision does not apply to barriers which are not required to support system OPERABILITY (see NRC Regulatory Issue Summary 2001-09, Control of Hazard Barriers, dated April 2, 2001.)

SHEARON HARRIS - UNIT 1 B 3/4 0-3 Amendment No. 162

APPLICABILITY BASES 3.0.6 (Continued)

The provisions of 3.0.6 are justified because of the low risk associated with required barriers not being capable of performing their related support function. This provision is based on consideration of the following initiating event categories:

Loss of coolant accidents; High energy line breaks; Feedwater line breaks; Internal flooding; External flooding; Turbine missile ejection; and Tornado or high wind.

The risk impact of the barriers which cannot perform their related support function(s) must be addressed pursuant to the risk assessment and management provision of the Maintenance Rule, 10 CFR 50.65(a)(4), and the associated implementation guidance, Regulatory Guide 1.160, Monitoring the Effectiveness of Maintenance at Nuclear Power Plants. Regulatory Guide 1.160 endorses the guidance in Section 11 of NUMARC 93-01, Revision 4A, Industry Guideline for Monitoring the Effectiveness of Maintenance at Nuclear Power Plants. This guidance provides for the consideration of dynamic plant configuration issues, emergent conditions, and other aspects pertinent to plant operation with the barriers unable to perform their related support function(s). These considerations may result in risk management and other compensatory actions being required during the period that barriers are unable to perform their related support function(s).

3.0.6 may be applied to one or more trains or subsystems of a system supported by barriers that cannot provide their related support function(s), provided that risk is assessed and managed (including consideration of the effects on Large Early Release and from external events). If applied concurrently to more than one train or subsystem of a multiple train or subsystem supported system, the barriers supporting each of these trains or subsystems must provide their related support function(s) for different categories of initiating events. For example, 3.0.6 may be applied for up to 30 days for more than one train of a multiple train supported system if the affected barrier for one train protects against internal flooding and the affected barrier for the other train protects against tornado missiles. In this example, the affected barrier may be the same physical barrier but serve different protection functions for each train.

If during the time that 3.0.6 is being used, the required OPERABLE train or subsystem becomes inoperable, it must be restored to OPERABLE status within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />. Otherwise, the train(s) or subsystem(s) supported by barriers that cannot perform their related support function(s) must be declared inoperable and the associated LCOs declared not met. This 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> period provides time to respond to emergent conditions that would otherwise likely lead to entry into LCO 3.0.3 and a rapid plant shutdown, which is not justified given the low probability of an initiating event which would require the barrier(s) not capable of performing their related support function(s). During this 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> period, the plant risk associated with the existing conditions is assessed and managed in accordance with 10 CFR 50.65(a)(4).

SHEARON HARRIS - UNIT 1 B 3/4 0-4 Amendment No. 162

APPLICABILITY BASES 4.0.1 Specification 4.0.1 establishes the requirement that surveillances must be met during the OPERATIONAL MODES or other specified conditions in the Applicability for which the requirements of the LCO apply, unless otherwise specified in the individual surveillances.

This Specification is to ensure that surveillances are performed to verify the OPERABILITY of systems and components, and that variables are within specified limits.

Failure to meet a surveillance within the specified surveillance interval, in accordance with Specification 4.0.2, constitutes a failure to meet an LCO. Surveillances may be performed by means of any series of sequential, overlapping, or total steps provided the entire surveillance is performed within the specified surveillance interval. Additionally, the definitions related to instrument testing (e.g., CHANNEL CALIBRATION) specify that these tests are performed by means of any series of sequential, overlapping, or total steps.

Systems and components are assumed to be OPERABLE when the associated surveillances have been met. Nothing in the Specification, however, is to be construed as implying that systems or components are OPERABLE when:

a. The systems or components are known to be inoperable, although still meeting the surveillances; or
b. The requirements of the surveillance(s) are known not to be met between required surveillance performances.

Surveillances do not have to be performed when the unit is in an OPERATIONAL MODE or other specified condition for which the requirements of the associated LCO are not applicable, unless otherwise specified. The surveillances associated with a test exception are only applicable when the test exception is used as an allowable exception to the requirements of a Specification.

Unplanned events may satisfy the requirements (including applicable acceptance criteria) for a given surveillance. In this case, the unplanned event may be credited as fulfilling the performance of the surveillance. This allowance includes those surveillances whose performance is normally precluded in a given OPERATIONAL MODE or other specified condition.

Surveillances, including surveillances invoked by ACTION requirements, do not have to be performed on inoperable equipment because the ACTION requirements define the remedial measures that apply. Surveillances have to be met and performed in accordance with Specification 4.0.2, prior to returning equipment to OPERABLE status.

Upon completion of maintenance, appropriate post maintenance testing is required to declare equipment OPERABLE. This includes ensuring applicable surveillances are not failed and their most recent performance is in accordance with Specification 4.0.2. Post maintenance testing may not be possible in the current OPERATIONAL MODE or other specified conditions in the Applicability due to the necessary unit parameters not having been established. In these situations, the equipment may be considered OPERABLE provided testing has been satisfactorily completed to the extent possible and the equipment is not otherwise believed to be incapable of performing its function. This will allow operations to proceed to an OPERATIONAL MODE or other specified condition where other necessary post maintenance tests can be completed.

SHEARON HARRIS - UNIT 1 B 3/4 0-5 Amendment No. 155



$33/,&$%,/,7<

%$6(6

 &RQWLQXHG 

$QH[DPSOHRIWKLVSURFHVVLV$X[LOLDU\)HHGZDWHU $): SXPSWXUELQHPDLQWHQDQFH

GXULQJUHIXHOLQJWKDWUHTXLUHVWHVWLQJDWVWHDPSUHVVXUHVWKDWFDQQRWEHREWDLQHGXQWLOWKH

XQLWLVDW+276+87'2:1FRQGLWLRQV+RZHYHULIRWKHUDSSURSULDWHWHVWLQJLV

VDWLVIDFWRULO\FRPSOHWHGWKH$):6\VWHPFDQEHFRQVLGHUHG23(5$%/(7KLVDOORZV

VWDUWXSDQGRWKHUQHFHVVDU\WHVWLQJWRSURFHHGXQWLOWKHSODQWUHDFKHVWKHVWHDPSUHVVXUH

UHTXLUHGWRSHUIRUPWKHWHVWLQJ

 7KHSURYLVLRQVRIWKLVVSHFLILFDWLRQHVWDEOLVKWKHOLPLWIRUZKLFKWKHVSHFLILHGWLPHLQWHUYDO

IRU6XUYHLOODQFH5HTXLUHPHQWVPD\EHH[WHQGHG  ,WSHUPLWVDQDOORZDEOHH[WHQVLRQRIWKH

QRUPDOVXUYHLOODQFHLQWHUYDOWRIDFLOLWDWHVXUYHLOODQFHVFKHGXOLQJDQGFRQVLGHUDWLRQRISODQW

RSHUDWLQJFRQGLWLRQVWKDWPD\QRWEHVXLWDEOHIRUFRQGXFWLQJVXUYHLOODQFHHJWUDQVLHQW

FRQGLWLRQVRURWKHURQJRLQJVXUYHLOODQFHRUPDLQWHQDQFHDFWLYLWLHV  ,WDOVRSURYLGHV

IOH[LELOLW\WRDFFRPPRGDWHWKHOHQJWKRIDIXHOF\FOHIRUVXUYHLOODQFHVWKDWDUHSHUIRUPHGDW

HDFKUHIXHOLQJRXWDJHDQGDUHVSHFLILHGZLWKDQPRQWKVXUYHLOODQFHLQWHUYDO  ,WLVQRW

LQWHQGHGWKDWWKLVSURYLVLRQEHXVHGUHSHDWHGO\WRH[WHQGVXUYHLOODQFHLQWHUYDOVEH\RQG

WKDWVSHFLILHGIRUVXUYHLOODQFHVWKDWDUHQRWSHUIRUPHGGXULQJUHIXHOLQJRXWDJHV 

/LNHZLVHLWLVQRWWKHLQWHQWWKDWWKHPRQWKLQWHUYDOVXUYHLOODQFHVEHSHUIRUPHGGXULQJ

SRZHURSHUDWLRQXQOHVVLWLVFRQVLVWHQWZLWKVDIHSODQWRSHUDWLRQ  7KHOLPLWDWLRQRI

6SHFLILFDWLRQLVEDVHGRQHQJLQHHULQJMXGJPHQWDQGWKHUHFRJQLWLRQWKDWWKHPRVW

SUREDEOHUHVXOWRIDQ\SDUWLFXODUVXUYHLOODQFHEHLQJSHUIRUPHGLVWKHYHULILFDWLRQRI

FRQIRUPDQFHZLWKWKH6XUYHLOODQFH5HTXLUHPHQWV  7KLVSURYLVLRQLVVXIILFLHQWWRHQVXUH

WKDWWKHUHOLDELOLW\HQVXUHGWKURXJKVXUYHLOODQFHDFWLYLWLHVLVQRWVLJQLILFDQWO\GHJUDGHG

EH\RQGWKDWREWDLQHGIURPWKHVSHFLILHGVXUYHLOODQFHLQWHUYDO

KHQD6HFWLRQVSHFLILFDWLRQVWDWHVWKDWWKHSURYLVLRQVRI65DUHDSSOLFDEOHD

H[WHQVLRQRIWKHWHVWLQJLQWHUYDOZKHWKHUVWDWHGLQWKHVSHFLILFDWLRQRULQFRUSRUDWHG

E\UHIHUHQFHLVSHUPLWWHG

7KHH[FHSWLRQVWR65DUHWKRVH6XUYHLOODQFHVIRUZKLFKWKHH[WHQVLRQRIWKH

LQWHUYDOVSHFLILHGLQWKH)UHTXHQF\GRHVQRWDSSO\7KHVHH[FHSWLRQVDUHVWDWHGLQWKH

LQGLYLGXDO6SHFLILFDWLRQV7KHUHTXLUHPHQWVRIUHJXODWLRQVWDNHSUHFHGHQFHRYHUWKH76

([DPSOHVRIZKHUH65GRHVQRWDSSO\DUHWKH&RQWDLQPHQW/HDNDJH5DWH7HVWLQJ

3URJUDPUHTXLUHGE\&)5$SSHQGL[-DQGWKHLQVHUYLFHWHVWLQJRISXPSVDQG

YDOYHVLQDFFRUGDQFHZLWKDSSOLFDEOH$PHULFDQ6RFLHW\RI0HFKDQLFDO(QJLQHHUV

2SHUDWLRQDQG0DLQWHQDQFH&RGHDVUHTXLUHGE\&)5D7KHVHSURJUDPV

HVWDEOLVKWHVWLQJUHTXLUHPHQWVDQG)UHTXHQFLHVLQDFFRUGDQFHZLWKWKHUHTXLUHPHQWVRI

UHJXODWLRQV7KH76FDQQRWLQDQGRIWKHPVHOYHVH[WHQGDWHVWLQWHUYDOVSHFLILHGLQWKH

UHJXODWLRQVGLUHFWO\RUE\UHIHUHQFH

 6SHFLILFDWLRQHVWDEOLVKHVWKHIOH[LELOLW\WRGHIHUGHFODULQJDIIHFWHGHTXLSPHQW

LQRSHUDEOHRUDQDIIHFWHGYDULDEOHRXWVLGHWKHVSHFLILHGOLPLWVZKHQDVXUYHLOODQFHKDVQRW

EHHQSHUIRUPHGZLWKLQWKHVSHFLILHGVXUYHLOODQFHLQWHUYDO  $GHOD\SHULRGRIXSWR

KRXUVRUXSWRWKHOLPLWRIWKHVSHFLILHGVXUYHLOODQFHLQWHUYDOZKLFKHYHULVJUHDWHU

DSSOLHVIURPWKHSRLQWLQWLPHWKDWLWLVGLVFRYHUHGWKDWWKHVXUYHLOODQFHKDVQRWEHHQ

SHUIRUPHGLQDFFRUGDQFHZLWK6SHFLILFDWLRQDQGQRWDWWKHWLPHWKDWWKHVSHFLILHG

VXUYHLOODQFHLQWHUYDOZDVQRWPHW

KHQD6HFWLRQVSHFLILFDWLRQVWDWHVWKDWWKHSURYLVLRQVRI65DUHDSSOLFDEOHLW

SHUPLWVWKHIOH[LELOLW\WRGHIHUGHFODULQJWKHWHVWLQJUHTXLUHPHQWQRWPHWLQDFFRUGDQFHZLWK

65ZKHQWKHWHVWLQJKDVQRWEHHQFRPSOHWHGZLWKLQWKHWHVWLQJLQWHUYDO LQFOXGLQJWKH

DOORZDQFHRI65LILQYRNHGE\WKH6HFWLRQVSHFLILFDWLRQ 

6+($521+$55,681,7   % $PHQGPHQW1R  

$33/,&$%,/,7<

%$6(6

 &RQWLQXHG 

7KLVGHOD\SHULRGSURYLGHVDGHTXDWHWLPHWRSHUIRUPVXUYHLOODQFHVWKDWKDYHEHHQPLVVHG

7KLVGHOD\SHULRGSHUPLWVWKHSHUIRUPDQFHRIDVXUYHLOODQFHEHIRUHFRPSO\LQJZLWK

$&7,21UHTXLUHPHQWVRURWKHUUHPHGLDOPHDVXUHVWKDWPLJKWSUHFOXGHSHUIRUPDQFHRIWKH

VXUYHLOODQFH

7KHEDVLVIRUWKLVGHOD\SHULRGLQFOXGHVFRQVLGHUDWLRQRIXQLWFRQGLWLRQVDGHTXDWH

SODQQLQJDYDLODELOLW\RISHUVRQQHOWKHWLPHUHTXLUHGWRSHUIRUPWKHVXUYHLOODQFHWKHVDIHW\

VLJQLILFDQFHRIWKHGHOD\LQFRPSOHWLQJWKHUHTXLUHGVXUYHLOODQFHDQGWKHUHFRJQLWLRQWKDW

WKHPRVWSUREDEOHUHVXOWRIDQ\SDUWLFXODUVXUYHLOODQFHEHLQJSHUIRUPHGLVWKHYHULILFDWLRQ

RIFRQIRUPDQFHZLWKWKHUHTXLUHPHQWV

KHQDVXUYHLOODQFHZLWKDVXUYHLOODQFHLQWHUYDOEDVHGQRWRQWLPHLQWHUYDOVEXWXSRQ

VSHFLILHGXQLWFRQGLWLRQVRSHUDWLQJVLWXDWLRQVRUUHTXLUHPHQWVRIUHJXODWLRQV HJSULRUWR

HQWHULQJ23(5$7,21$/02'(DIWHUHDFKIXHOORDGLQJRULQDFFRUGDQFHZLWK&)5

$SSHQGL[-DVPRGLILHGE\DSSURYHGH[HPSWLRQVHWF LVGLVFRYHUHGWRQRWKDYHEHHQ

SHUIRUPHGZKHQVSHFLILHG6SHFLILFDWLRQDOORZVIRUWKHIXOOGHOD\SHULRGRIXSWRWKH

VSHFLILHGVXUYHLOODQFHLQWHUYDOWRSHUIRUPWKHVXUYHLOODQFH+RZHYHUVLQFHWKHUHLVQRWD

WLPHLQWHUYDOVSHFLILHGWKHPLVVHGVXUYHLOODQFHVKRXOGEHSHUIRUPHGDWWKHILUVWUHDVRQDEOH

RSSRUWXQLW\

6SHFLILFDWLRQSURYLGHVDWLPHOLPLWIRUDQGDOORZDQFHVIRUWKHSHUIRUPDQFHRI

VXUYHLOODQFHVWKDWEHFRPHDSSOLFDEOHDVDFRQVHTXHQFHRI23(5$7,21$/02'(

FKDQJHVLPSRVHGE\$&7,21UHTXLUHPHQWV 

6SHFLILFDWLRQLVRQO\DSSOLFDEOHLIWKHUHLVDUHDVRQDEOHH[SHFWDWLRQWKHDVVRFLDWHG

HTXLSPHQWLV23(5$%/(RUWKDWYDULDEOHVDUHZLWKLQOLPLWVDQGLWLVH[SHFWHGWKDWWKH

6XUYHLOODQFHZLOOEHPHWZKHQSHUIRUPHG0DQ\IDFWRUVVKRXOGEHFRQVLGHUHGVXFKDVWKH

SHULRGRIWLPHVLQFHWKH6XUYHLOODQFHZDVODVWSHUIRUPHGRUZKHWKHUWKH6XUYHLOODQFHRUD

SRUWLRQWKHUHRIKDVHYHUEHHQSHUIRUPHGDQGDQ\RWKHULQGLFDWLRQVWHVWVRUDFWLYLWLHV

WKDWPLJKWVXSSRUWWKHH[SHFWDWLRQWKDWWKH6XUYHLOODQFHZLOOEHPHWZKHQSHUIRUPHG$Q

H[DPSOHRIWKHXVHRI6SHFLILFDWLRQZRXOGEHDUHOD\FRQWDFWWKDWZDVQRWWHVWHGDV

UHTXLUHGLQDFFRUGDQFHZLWKDSDUWLFXODU65EXWSUHYLRXVVXFFHVVIXOSHUIRUPDQFHVRIWKH

65LQFOXGHGWKHUHOD\FRQWDFWWKHDGMDFHQWSK\VLFDOO\FRQQHFWHGUHOD\FRQWDFWVZHUH

WHVWHGGXULQJWKH65SHUIRUPDQFHWKHVXEMHFWUHOD\FRQWDFWKDVEHHQWHVWHGE\DQRWKHU

65RUKLVWRULFDORSHUDWLRQRIWKHVXEMHFWUHOD\FRQWDFWKDVEHHQVXFFHVVIXO,WLVQRW

VXIILFLHQWWRLQIHUWKHEHKDYLRURIWKHDVVRFLDWHGHTXLSPHQWIURPWKHSHUIRUPDQFHRIVLPLODU

HTXLSPHQW7KHULJRURIGHWHUPLQLQJZKHWKHUWKHUHLVDUHDVRQDEOHH[SHFWDWLRQD

6XUYHLOODQFHZLOOEHPHWZKHQSHUIRUPHGVKRXOGLQFUHDVHEDVHGRQWKHOHQJWKRIWLPH

VLQFHWKHODVWSHUIRUPDQFHRIWKH6XUYHLOODQFH,IWKH6XUYHLOODQFHKDVEHHQSHUIRUPHG

UHFHQWO\DUHYLHZRIWKH6XUYHLOODQFHKLVWRU\DQGHTXLSPHQWSHUIRUPDQFHPD\EH

VXIILFLHQWWRVXSSRUWDUHDVRQDEOHH[SHFWDWLRQWKDWWKH6XUYHLOODQFHZLOOEHPHWZKHQ

SHUIRUPHG)RU6XUYHLOODQFHVWKDWKDYHQRWEHHQSHUIRUPHGIRUDORQJSHULRGRUWKDWKDYH

QHYHUEHHQSHUIRUPHGDULJRURXVHYDOXDWLRQEDVHGRQREMHFWLYHHYLGHQFHVKRXOGSURYLGH

DKLJKGHJUHHRIFRQILGHQFHWKDWWKHHTXLSPHQWLV23(5$%/(7KHHYDOXDWLRQVKRXOGEH

GRFXPHQWHGLQVXIILFLHQWGHWDLOWRDOORZDNQRZOHGJHDEOHLQGLYLGXDOWRXQGHUVWDQGWKH

EDVLVIRUWKHGHWHUPLQDWLRQ

)DLOXUHWRFRPSO\ZLWKVSHFLILHGVXUYHLOODQFHLQWHUYDOVIRUVXUYHLOODQFHUHTXLUHPHQWVLV

H[SHFWHGWREHDQLQIUHTXHQWRFFXUUHQFH8VHRIWKHGHOD\SHULRGHVWDEOLVKHGE\

6SHFLILFDWLRQLVDIOH[LELOLW\ZKLFKLVQRWLQWHQGHGWREHXVHGUHSHDWHGO\WRH[WHQG

VXUYHLOODQFHLQWHUYDOV:KLOHXSWRKRXUVRUWKHOLPLWRIWKHVSHFLILHGVXUYHLOODQFHLQWHUYDO

LVSURYLGHGWRSHUIRUPWKHPLVVHGVXUYHLOODQFHLWLVH[SHFWHGWKDWWKHPLVVHGVXUYHLOODQFH

6+($521+$55,681,7   % $PHQGPHQW1R  

$33/,&$%,/,7<

%$6(6

 &RQWLQXHG 

ZLOOEHSHUIRUPHGDWWKHILUVWUHDVRQDEOHRSSRUWXQLW\7KHGHWHUPLQDWLRQRIWKHILUVW

UHDVRQDEOHRSSRUWXQLW\VKRXOGLQFOXGHFRQVLGHUDWLRQRIWKHLPSDFWRQSODQWULVN IURP

GHOD\LQJWKHVXUYHLOODQFHDVZHOODVDQ\SODQWFRQILJXUDWLRQFKDQJHVUHTXLUHGRUVKXWWLQJ

WKHSODQWGRZQWRSHUIRUPWKHVXUYHLOODQFH DQGLPSDFWRQDQ\DQDO\VLVDVVXPSWLRQVLQ

DGGLWLRQWRXQLWFRQGLWLRQVSODQQLQJDYDLODELOLW\RISHUVRQQHODQGWKHWLPHUHTXLUHGWR

SHUIRUPWKHVXUYHLOODQFH7KLVULVNLPSDFWVKRXOGEHPDQDJHGWKURXJKWKHSURJUDPLQ

SODFHWRLPSOHPHQW&)5 D  DQGLWVLPSOHPHQWDWLRQJXLGDQFH15&5HJXODWRU\

  • XLGHµ$VVHVVLQJDQG0DQDJLQJ5LVN%HIRUH0DLQWHQDQFH$FWLYLWLHVDW1XFOHDU

3RZHU3ODQWV¶7KLV5HJXODWRU\*XLGHDGGUHVVHVFRQVLGHUDWLRQRIWHPSRUDU\DQG

DJJUHJDWHULVNLPSDFWVGHWHUPLQDWLRQRIULVNPDQDJHPHQWDFWLRQWKUHVKROGVDQGULVN

PDQDJHPHQWDFWLRQXSWRDQGLQFOXGLQJSODQWVKXWGRZQ7KHPLVVHGVXUYHLOODQFHVKRXOG

EHWUHDWHGDVDQHPHUJHQWFRQGLWLRQDVGLVFXVVHGLQWKH5HJXODWRU\*XLGH7KHULVN

HYDOXDWLRQPD\XVHTXDQWLWDWLYHTXDOLWDWLYHRUEOHQGHGPHWKRGV7KHGHJUHHRIGHSWK

DQGULJRURIWKHHYDOXDWLRQVKRXOGEHFRPPHQVXUDWHZLWKWKHLPSRUWDQFHRIWKH

FRPSRQHQW0LVVHGVXUYHLOODQFHVIRULPSRUWDQWFRPSRQHQWVVKRXOGEHDQDO\]HG

TXDQWLWDWLYHO\,IWKHUHVXOWVRIWKHULVNHYDOXDWLRQGHWHUPLQHWKHULVNLQFUHDVHLVVLJQLILFDQW

WKLVHYDOXDWLRQVKRXOGEHXVHGWRGHWHUPLQHWKHVDIHVWFRXUVHRIDFWLRQ$OOPLVVHG

VXUYHLOODQFHVZLOOEHSODFHGLQWKHOLFHQVHH¶V&RUUHFWLYH$FWLRQ3URJUDP

,IDVXUYHLOODQFHLVQRWFRPSOHWHGZLWKLQWKHDOORZHGGHOD\SHULRGWKHQWKHHTXLSPHQWLV

FRQVLGHUHGLQRSHUDEOHRUWKHYDULDEOHLVFRQVLGHUHGRXWVLGHWKHVSHFLILHGOLPLWVDQGWKH

WLPHOLPLWVRIWKH$&7,21UHTXLUHPHQWVIRUWKHDSSOLFDEOH/&2EHJLQLPPHGLDWHO\XSRQ

H[SLUDWLRQRIWKHGHOD\SHULRG,IDVXUYHLOODQFHLVIDLOHGZLWKLQWKHGHOD\SHULRGWKHQWKH 

HTXLSPHQWLVLQRSHUDEOHRUWKHYDULDEOHLVRXWVLGHWKHVSHFLILHGOLPLWVDQGWKHWLPHOLPLWVRI

WKH$&7,21UHTXLUHPHQWVIRUWKHDSSOLFDEOH/&2EHJLQLPPHGLDWHO\XSRQWKHIDLOXUHRI

WKHVXUYHLOODQFH

&RPSOHWLRQRIWKHVXUYHLOODQFHZLWKLQWKHGHOD\SHULRGDOORZHGE\WKLV6SHFLILFDWLRQRU

ZLWKLQWKHFRPSOHWLRQWLPHRIWKH$&7,216UHVWRUHVFRPSOLDQFHZLWK6SHFLILFDWLRQ

 7KLVVSHFLILFDWLRQHVWDEOLVKHVWKHUHTXLUHPHQWWKDWDOODSSOLFDEOHVXUYHLOODQFHVPXVWEH

PHWEHIRUHHQWU\LQWRDQ23(5$7,21$/02'(RURWKHUFRQGLWLRQRIRSHUDWLRQVSHFLILHG

LQWKH$SSOLFDELOLW\VWDWHPHQW  7KHSXUSRVHRIWKLVVSHFLILFDWLRQLVWRHQVXUHWKDWV\VWHP

DQGFRPSRQHQW23(5$%,/,7<UHTXLUHPHQWVRUSDUDPHWHUOLPLWVDUHPHWEHIRUHHQWU\LQWR

D02'(RUFRQGLWLRQIRUZKLFKWKHVHV\VWHPVDQGFRPSRQHQWVHQVXUHVDIHRSHUDWLRQRI

WKHIDFLOLW\  7KLVSURYLVLRQDSSOLHVWRFKDQJHVLQ23(5$7,21$/02'(6RURWKHU

VSHFLILHGFRQGLWLRQVDVVRFLDWHGZLWKSODQWVKXWGRZQDVZHOODVVWDUWXS

8QGHUWKHSURYLVLRQVRIWKLVVSHFLILFDWLRQWKHDSSOLFDEOH6XUYHLOODQFH5HTXLUHPHQWVPXVW

EHSHUIRUPHGZLWKLQWKHVSHFLILHGVXUYHLOODQFHLQWHUYDOWRHQVXUHWKDWWKH/LPLWLQJ

&RQGLWLRQVIRU2SHUDWLRQDUHPHWGXULQJLQLWLDOSODQWVWDUWXSRUIROORZLQJDSODQWRXWDJH

KHQDVKXWGRZQLVUHTXLUHGWRFRPSO\ZLWK$&7,21UHTXLUHPHQWVWKHSURYLVLRQVRI

6SHFLILFDWLRQGRQRWDSSO\EHFDXVHWKLVZRXOGGHOD\SODFLQJWKHIDFLOLW\LQDORZHU

02'(RIRSHUDWLRQ

 '(/(7('









6+($521+$55,681,7  % $PHQGPHQW1R  

3/4.1 REACTIVITY CONTROL SYSTEMS BASES 3/4.1.1 BORATION CONTROL 3/4.1.1.1 and 3/4.1.1.2 SHUTDOWN MARGIN A sufficient SHUTDOWN MARGIN ensures that: (1) the reactor can be made subcritical from all operating conditions, (2) the reactivity transients associated with postulated accident conditions are controllable within acceptable limits, and (3) the reactor will be maintained sufficiently subcritical to preclude inadvertent criticality in the shutdown condition.

SHUTDOWN MARGIN requirements vary throughout core life as a function of fuel depletion, RCS boron concentration, and RCS Tavg. In MODES 1 and 2 the most restrictive condition occurs at EOL, with Tavg at no load operating temperature, and is associated with a postulated steam line break accident and resulting uncontrolled RCS cooldown. In the analysis of this accident, a minimum SHUTDOWN MARGIN as specified in the CORE OPERATING LIMITS REPORT is required to control the severity of the transient. Accordingly, the SHUTDOWN MARGIN requirement is based upon this limiting condition and is consistent with FSAR safety analysis assumptions. In MODES 3, 4, and 5, the most restrictive condition occurs at BOL, when the boron concentration is the greatest. In these modes, the required SHUTDOWN MARGIN is composed of a constant requirement and a variable requirement, which is a function of the RCS critical boron concentration with all rods inserted minus the highest worth rod (ARI-HWR). The constant SHUTDOWN MARGIN requirement is based on an uncontrolled RCS cooldown from a steamline break accident, as is the case for MODES 1 and 2. The variable SHUTDOWN MARGIN requirement is based on the results of boron dilution accident analyses, where the SHUTDOWN MARGIN is varied as a function of ARI-HWR RCS critical boron concentration, to guarantee a minimum of 15 minutes for operator action prior to a loss of SHUTDOWN MARGIN.

In modes 3, 4, and 5, the figure specified in the CORE OPERATING LIMITS REPORT (COLR) must be used with a curve giving the required shutdown boron concentrations for various temperatures as a function of core burnup. This cycle dependent relationship is provided for each cycle in a pre-calculated operating data package. From this data, ARI-HWR RCS critical boron concentration, required SHUTDOWN MARGIN, and the required boron concentration that will preserve the SHUTDOWN MARGIN limit can be determined.

The boron dilution analysis considers the smallest RCS water volume in which unborated water is mixed. For MODE 1-3, forced circulation provided by the reactor coolant pumps (RCPs) will mix with the inventory in the reactor vessel and each of the reactor coolant loops. For conditions in MODE 4 and 5 where at least one RCP is in operation, the dilution volume is equivalent to that assumed for MODE 1-3. For other conditions in MODE 4 with only a single train of the Residual Heat Removal (RHR) System in operation, regions of the RCS that experience reduced flow conditions in absence of forced RCP flow are excluded from the dilution volume calculation. For MODE 5, reactor coolant water level may be drained to an elevation below the top of the main coolant loop piping, and at least one train of the RHR system may be operating, resulting in the potential for a dilution event with reduced inventory. No analysis is performed for a boron dilution event in MODE 6, since administrative controls are in place to prevent an uncontrolled boron dilution while the unit is in the refueling mode. Required boron concentrations necessary to satisfy acceptance criteria for the boron dilution accident are implemented by the variable SHUTDOWN MARGIN requirements.

SHUTDOWN MARGIN verification includes the assumption that the highest worth rod remains stuck out of the core. In the event that a rod is known to be untrippable, SDM verification must account for the worth of the untrippable rod as well as another rod of maximum worth. However, with all rods verified as fully inserted by two independent means, it is not necessary to account for a stuck rod in the SHUTDOWN MARGIN calculation.

SHEARON HARRIS - UNIT 1 B 3/4 1-1 Amendment No. 171

  • ~::-.:- :-:- .
  • *.. *r; REACTlVITY CONTROL SYSTEMS BASES *.!

3/4.1.1.3 MODERATOR TEMPERATURE COEFFICIENT The limitations on moderator temperature coefficient (HTC) are provided to ensure that the value of this coefficient remains within the limiting condition assumed in the FSAR accident and transient analyses.

The HTC values of this specification are applicable to a specific set of plant conditions; i.e., the positive limit is based on core conditions for all rods withdrawn, BOL, hot zero THERMAL POWER, and the negative limit is based on core conditions for all rods withdrawn, EOL, RATED THERMAL POWEi. Accordingly, veri-flcation of HTC values at conditions other than those explicitly stated will r*tquire extrapolation to those conditions in order to permit an accurate comparison.

'\

SHEARON HARllIS - UNIT l 8 3/4 1-la Amendment No. 7

. . . . . *--.--.-- . . *_ *.:,**'.'>"'. . . . . . . . . ... -.;,,?.* *-- ,*:.:.:-~*. *....... . -~';,-:.*-. ** --.,_:- , ~ . * * * .*.*.'.:,.'"*"~ .... - - . * .---~- ** *******-**.*

REACTIVITY CONTROL SYSTEMS BASES MODERATOR TEMPERATURE COEFFICIENT (Continued)

The Surveillance Requirements for measurement of the MTC at the beginning and near the end of the fuel cycle are adequate to confirm that the MTC remains within its limits since this coefficient changes slowly due principally to the reduction in RCS boron concentration associated with fuel burnup.

3/4.1.1.4 MINIMUM TEMPERATURE FOR CRITICALITY This specification ensures that the reactor will not be made critical with the Reactor Coolant System average temperature less than 551°F. This limitation is required to ensure: (1) the moderator temperature coefficient is within its analyzed temperature range, (2) the trip instrumentation is within its normal operating range, (3) the pressurizer is capable of being in an OPERABLE status with a steam bubble, and (4) the reactor vessel is above its minimum RTNDT temperature*

3/4.1.2 BORATION SYSTEMS The Boron Injection System ensures that negative reactivity control is available during each mode of facility operation. The components required to perform this function include: (1) borated water sources, (2) chargipg/safety injection pumps, (3) separate flow paths, (4) boric acid transfer pumps, and (5) an emergency power supply from OPERABLE diesel generators.

With the RCS average temperature above 350°F, a minimum of two boron injection flow paths are required to ensure single functional capability in the event an assumed failure renders one of the flow paths inoperable. The boration capability of either flow path is sufficient to provide the required SHUTDOWN MARGIN as defined by Specification 3/4.1.1.2 after xenon decay and cooldown to 200°F. The maximum expected boration capability requirement occurs at BOL SHEARON HARRIS - UNIT 1 B 3/4 1-2 Amendment No. 46

REACTIVITY CONTROL SYSTEMS BASES 3/4.1.2 BORATION SYSTEMS (Continued) from full power equilibrium xenon conditions and requires 24,150 gallons of water with a boron concentration within the limits specified in the Core Operating Limits Report be maintained in the boric acid storage tanks or 436,000 gallons of water with a boron concentration within the limits specified in the Core Operating Limits Report be maintained in the refueling water storage tank (RWST).

With the RCS temperature below 350°F, one boron injection flow path is acceptable without single failure consideration on the basis of the stable reactivity SHEARON HARRIS - UNIT 1 B 3/4 1-2a Amendment No. 171

REACTIVITY CONTROL SYSTEMS BASES BORATION SYSTEMS (Continued) condition of the reactor and the additional restrictions prohibiting CORE ALTERATIONS and positive reactivity changes in the event the single boron injection flow path becomes inoperable.

The limitation for a maximum of one charging/safety injection pump (CSIP) to be OPERABLE and the Surveillance Requirement to verify all CSIPs except the required OPERABLE pump to be inoperable below 325°F provides assurance that a mass addition pressure transient can be relieved by the operation of a single PORV.

The boron capability required below 200°F is sufficient to provide the required SHUTDOWN MARGIN as defined by Specification 3/4.1.1.2 after xenon decay and cooldown from 200°F to 140°F. This condition requires either 7150 gallons of water with a boron concentration within the limits specified in the Core Operating Limits Report be maintained in the boric acid storage tanks or 106,000 gallons of water with a boron concentration within the limits specified in the Core Operating Limits Report be maintained in the RWST.

The gallons given above are the amounts that need to be maintained in the tank in the various circumstances. To get the specified indicated levels used for surveillance testing, each value had added to it an allowance for the unusable volume of water in the tank, allowances for other identified needs, and an allowance for possible instrument error. In addition, for human factors purposes, the percent indicated levels were then raised to either the next whole percent or the next even percent and the gallon figures rounded off. This makes the LCO values conservative to the analyzed values.

The limits on contained water volume and boron concentration of the RWST also ensure a pH value of between 7.0 and 11.0 for the solution recirculated within containment after a LOCA.

This pH band minimizes the evolution of iodine and minimizes the effect of chloride and caustic stress corrosion on mechanical systems and components.

The BAT minimum temperature of 65°F ensures that boron solubility is maintained for concentrations of at least the 7750 ppm limit. The RWST minimum temperature is consistent with the STS value and is based upon other considerations since solubility is not an issue at the specified concentration levels. The RWST high temperature was selected to be consistent with analytical assumptions for containment heat load.

The OPERABILITY of one Boron Injection System during REFUELING ensures that this system is available for reactivity control while in MODE 6.

3/4.1.3 MOVABLE CONTROL ASSEMBLIES The specifications of this section ensure that: (1) acceptable power distribution limits are maintained, (2) the minimum SHUTDOWN MARGIN is maintained, and (3) the potential effects of rod misalignment on associated accident analyses are limited. OPERABILITY of the control rod position indicators is required to determine control rod positions and thereby ensure compliance with the control rod alignment and insertion limits.

SHEARON HARRIS - UNIT 1 B 3/4 1-3 Amendment No. 171

REACTIVITY CONTROL SYSTEMS BASES MOVABLE CONTROL ASSEMBLIES (Continued)

The OPERABILITY (i.e., trippability) of the shutdown and control rods is an initial assumption in all safety analyses that assume rod insertion upon reactor trip. Maximum rod misalignment is an initial assumption in the safety analysis that directly affects core power distributions and assumptions of available SDM.

The limits on shutdown or control rod alignments ensure that the assumptions in the safety analysis will remain valid. The requirements on control rod OPERABILITY ensure that upon reactor trip, the assumed reactivity will be available and will be inserted. The control rod OPERABILITY requirements (i.e., trippability) are separate from the alignment requirements, which ensure that the rod cluster control assemblies and banks maintain the correct power distribution and rod alignment. The rod OPERABILITY requirement is satisfied provided the rod will fully insert in the required rod drop time assumed in the safety analysis. Rod control malfunctions that result in the inability to move a rod (e.g., rod lift coil failures), but that do not impact trippability, do not result in rod Inoperability. Expeditious action will be taken to determine if rod immovability is caused by an electrical problem in the rod control system.

The ACTION statements which permit limited variations from the basic requirements are accompanied by additional restrictions which ensure that the original design criteria are met.

Misalignment of a rod requires measurement of peaking factors and a restriction in THERMAL POWER. These restrictions provide assurance of fuel rod integrity during continued operation.

In addition, those safety analyses affected by a misaligned rod are reevaluated to confirm that the results remain valid during future operation.

The maximum rod drop time restriction is consistent with the assumed rod drop time used in the safety analyses. Measurement with Tavg greater than or equal to 551°F and with all reactor coolant pumps operating ensures that the measured drop times will be representative of insertion times experienced during a Reactor trip at operating conditions.

Control rod positions and OPERABILITY of the rod position indicators are required to be verified at the frequency specified in the Surveillance Frequency Control Program with more frequent verifications required if an automatic monitoring channel is inoperable. These verification frequencies are adequate for assuring that the applicable LCOs are satisfied.

SHEARON HARRIS - UNIT 1 B 3/4 1-4 Amendment No. 168

3/4.2 POWER DISTRIBUTION LIMITS BASES The specifications of this section provide assurance of fuel integrity during Condition I (Normal Operation) and II (Incidents of Moderate Frequency) events by: (1) maintaining the minimum DNBR in the core greater than or equal to the design DNBR value during normal operation and in short-term transients, and (2) limiting the fission gas release, fuel pellet temperature, and cladding mechanical properties to within assumed design criteria. In addition, limiting the peak linear power density during Condition I events provides assurance that the initial conditions assumed for the LOCA analyses are met and the ECCS acceptance criteria limit of 2200°F is not exceeded.

The definitions of certain hot channel and peaking factors as used in these specifications are as follows:

( , , ) Heat Flux Hot Channel Factor, is defined as the maximum local fuel rod linear power density divided by the average fuel rod linear power density, assuming nominal fuel pellet and fuel rod dimensions. Therefore, ( , , ) is a measure of the maximum power density at elevation Z for each radial location (X,Y).

( , ) Nuclear Enthalpy Rise Hot Channel Factor, is defined as the ratio of the integral of the linear power along a fuel rod to the average integrated fuel rod power.

Therefore, ( , ) is a measure of the total power produced in a fuel rod at each radial location (X,Y).

3/4.2.1 AXIAL FLUX DIFFERENCE AXIAL FLUX DIFFERENCE (AFD) is a measure of the axial power distribution skewing to either the top or bottom half of the core. The AFD is sensitive to many core related parameters such as control bank positions, core power level, axial burnup, axial xenon distribution, and, to a lesser extent, reactor coolant temperature and boron concentration. AFD limits are included in the CORE OPERATING LIMITS REPORT.

The allowed range of the AFD is used in the nuclear design process to confirm that operation within these limits produces core peaking factors and axial power distributions that meet safety analysis requirements. AFD limits are developed based on the core operating limits (maneuvering analysis) methodology described in DPC-NE-2011-P-A. The maneuvering analysis uses a three-dimensional nodal reactor model to calculate a set of power distributions at several points in the core life. Power distributions are calculated with abnormal xenon distributions to ensure predicted power distributions are conservative with respect to those expected to occur. Peaking factors from these power distributions are then evaluated against various thermal limits. This evaluation then confirms the adequacy of current power dependent AFD limits, rod insertion limits, and the F(I) penalty functions for Overpower T and the Overtemperature T RPS trip functions, or provides the bases for establishing new limits. The development of operational AFD limits and the F(I) functions are established such to exclude the power distributions that exceed the respective thermal limits.

The limits on the AFD ensure that the Heat Flux Hot Channel Factor ( ( , , )) is not exceeded during either normal operation or in the event of xenon redistribution following power changes.

The limits on the AFD also restrict the range of power distributions that are used as initial conditions in the analyses of Condition II, III, or IV events. This ensures that the fuel cladding integrity is maintained within respective limits for these postulated accidents. The most important Condition III or IV event is the LOCA. The most important Condition II events include loss of flow, uncontrolled bank withdrawal, and boration or dilution accidents. Condition II and III accidents simulated to begin from within the AFD limits are used to confirm the adequacy of the Overpower T and Overtemperature T trip setpoints.

SHEARON HARRIS - UNIT 1 B 3/4 2-1 Amendment No. 171

POWER DISTRIBUTION LIMITS BASES AXIAL FLUX DIFFERENCE (Continued)

Although the maneuvering analysis defines limits that must be met to satisfy safety analyses, typically a target operating band is used to control axial power distribution in day to day operation.

This requires that the AFD be controlled within a narrow tolerance band around a burnup dependent target. The constant target band is typically smaller and lies within the maneuvering analysis operating space. Control within the constant target band constrains the variation of axial xenon and power distributions during normal operation and unit maneuvers.

The computer determines the one-minute average of each of the OPERABLE excore detector outputs and provides an alarm message immediately if the AFD for two or more OPERABLE excore channels are outside the AFD limits specified in the COLR. These alarms are active when power is greater than 50% of RATED THERMAL POWER.

SHEARON HARRIS - UNIT 1 B 3/4 2-2 Amendment No. 171

POWER DISTRIBUTION LIMITS BASES 3/4.2.2 AND 3/4.2.3 HEAT FLUX HOT CHANNEL FACTOR AND NUCLEAR ENTHALPY RISE HOT CHANNEL FACTOR The limits on heat flux hot channel factor and enthalpy rise hot channel factor ensure that: (1) the design limits on peak local power density and minimum DNBR are not exceeded and (2) in the event of a LOCA the peak fuel clad temperature will not exceed the 2200°F ECCS acceptance criteria limit.

( , ) and ( , , ) are not directly measurable but are inferred from a power distribution map obtained with the movable incore detector system. ( , ) and ( , , ) will normally only be determined periodically as specified in Specifications 4.2.2 and 4.2.3 and in accordance with the Surveillance Frequency Control Program. This periodic surveillance is sufficient to ensure that the limits are maintained provided:

a. Control rods in a single group move together with no individual rod insertion differing by more than +/- 12 steps, indicated, from the group demand position;
b. Control rod groups are sequenced with overlapping groups as described in Specification 3.1.3.6;
c. The control rod insertion limits of Specifications 3.1.3.5 and 3.1.3.6 are maintained; and
d. The axial power distribution, expressed in terms of AXIAL FLUX DIFFERENCE, is maintained within the limits.

( , ) will be maintained within its limits provided Conditions a. through d. above are maintained.

( , ) shall be limited by the following relationship:

( , ) ( , )

where: ( , ) is defined as the measured radial peak

( , ) is defined as the steady state maximum allowable radial peak defined in the COLR.

The ( , ) limit defines the coolant flow channel with the maximum enthalpy rise required to prevent fuel design criteria from being exceeded. This channel has the highest probability for DNB. ( , ) limits are maximum allowable radial peak (MARP) limits. MARP limits are constant DNBR limits which are a function of both the magnitude and location of the axial peak F(Z), therefore, justifying the X,Y dependence of the ( , ) limit.

The limiting value, ( , ) , is also power dependent and can be described by the following relationship:

( , ) = MARP(X,Y) * [1.0 + (1/RRH) * (1.0 - P)]

where: MARP(X,Y) is the maximum allowable radial peaks provided in the COLR, P is the ratio of THERMAL POWER to RATED THERMAL POWER, and RRH is the amount by which allowable THERMAL POWER must be reduced for each 1% that ( , ) exceeds the limit. The specific value is contained in the COLR.

SHEARON HARRIS - UNIT 1 B 3/4 2-2a Amendment No. 171

FIGURE B 3/4 2-1 DELETED SHEARON HARRIS - UNIT l B 3/4 2-3 Amendment No. 7

POWER DISTRIBUTION LIMITS BASES HEAT FLUX HOT CHANNEL FACTOR AND NUCLEAR ENTHALPY RISE HOT CHANNEL FACTOR (Continued)

With ( , ) exceeding its limit, THERMAL POWER must be reduced by RRH%, along with additional adjustments to the reactor protection system required to ensure continued protection of DNBR design limits. Specifically, the Power Range Neutron Flux - High Trip Setting trip function Setpoint is reduced by RRH% for each 1% that ( , ) exceeds the limit, and the Overtemperature T Trip Setpoint (K1) by TRH for each 1% that ( , ) exceeds the limit.

Surveillance Requirement 4.2.3.2.a states that ( , ) shall be within its steady state limit,

( , ) , described above. The nuclear design process includes calculations performed to determine that the core can be operated within the ( , ) limits. Because flux maps are taken in steady state conditions, the variations in power distribution resulting from normal operational maneuvers are not present in the flux map data. These variations are, however, conservatively calculated by considering a wide range of unit maneuvers in normal operation.

The maximum peaking factor increase over steady state values is determined to prevent DNB during transient conditions. This limit is ( , ) , which is verified by Surveillance Requirement 4.2.3.2.b. This Surveillance compares the measured ( , ) to the Surveillance limit to ensure that safety analysis limits are maintained. Surveillance Requirement 4.2.3.2.c requires an evaluation of the trend in ( , ) , by extrapolation to +31 EFPD beyond the most recent measurement, against ( , ) evaluated at +31 EFPD burnup, to account for any increase in ( , ) that may occur and cause the ( , ) limit to be exceeded before the next required ( , ) evaluation. As a result of this evaluation, either ( , )

is reverified with ( , ) increased by a factor specified in the COLR, or Surveillance Requirement 4.2.3.2.b is repeated prior to the time at which the extrapolated margin becomes zero.

An uncertainty for measured radial peaks applicable to ( , ) is specified in the COLR. If this uncertainty is already accounted for in the surveillance limit ( , ) , then a value of zero may be specified.

When an ( , , ) measurement is taken, an allowance for both experimental error and manufacturing tolerance must be made. An allowance of 5% is appropriate for a full-core map taken with the Incore Detector Flux Mapping System, and a 3% allowance is appropriate for manufacturing tolerance.

Limits on ( , , ) preserve the value of the initial total peaking factor assumed in the accident analysis. ( , , ) limits assumed in the LOCA analysis are typically most limiting, ensuring that fuel design criteria for peak cladding temperature are not violated.

( , , ) is measured periodically using the incore detector system. These measurements are generally taken with the core at, or near, steady state conditions. Using the measured three-dimensional power distributions, it is possible to derive a measured value for ( , , ).

However, because this value represents a steady state condition, it does not include the variations in the value of ( , , ) that are present during nonequilibrium situations. To account for these possible variations, the ( , , ) limit is reduced by pre-calculated factors to account for perturbations from steady state conditions to the operating limits. Core monitoring and control under non-steady state conditions are accomplished by operating the core within the limits of the appropriate LCOs, including the limits on the AXIAL FLUX DIFFERENCE of Specification 3.2.1 and ROD INSERTION of Specifications 3.1.3.5 and 3.1.3.6.

SHEARON HARRIS - UNIT 1 B 3/4 2-4 Amendment No. 171

POWER DISTRIBUTION LIMITS BASES HEAT FLUX HOT CHANNEL FACTOR AND NUCLEAR ENTHALPY RISE HOT CHANNEL FACTOR (Continued)

Measured ( , , ) is compared against three limits per Surveillance Requirement 4.2.2.2.c:

  • A steady-state limit, ( ) ( ), where P is the fraction of RATED THERMAL POWER, K(Z) is the normalized as a function of core height, and K(BU) is the normalized as a function of burnup. K(Z) and K(BU) are both specified in the COLR.
  • A transient operational limit, ( , , ) , which is the cycle dependent maximum allowable design peaking factor ensuring that the ( , , ) limit will be preserved for operation within the AXIAL FLUX DIFFERENCE limits of Specification 3/4.2.1 and ROD INSERTION LIMITS of Specifications 3.1.3.5 and 3.1.3.6. ( , , ) comprises pre-calculated factors accounting for perturbations from steady state conditions to the operating limits.
  • A transient reactor protection limit, ( , , ) , which is the cycle dependent maximum allowable design peaking factor which ensures that the centerline fuel melt limit will be preserved for Condition I and II transients. ( , , ) comprises pre-calculated factors accounting for perturbations from steady state conditions to the operating limits.

Measured ( , , ) is either increased by factors to account for both manufacturing tolerances and measurement uncertainty prior to comparison with the limit, or these factors are included in the ( , , ) and ( , , ) surveillance limits specified in the COLR.

Per Surveillance Requirement 4.2.2.2.d, an ( , , ) measurement is required after a power rise of 10% RTP over the THERMAL POWER at which it was last verified to be in limits, or at the frequency specified in the Surveillance Frequency Control Program, whichever occurs first. This surveillance requirement is modified by a note applicable to the first power ascension after refueling, stating that THERMAL POWER may be increased until an equilibrium power level has been achieved at which a power distribution map can be obtained. Because ( , , ) could not have previously been measured in this reload core, power may be increased to RTP prior to an equilibrium verification of ( , , ) provided one or more measurements of ( , , ) are performed at various power levels during startup physics testing. This ensures that some determination of ( , , ) is made at a lower power level at which adequate margin is available before going to full power operation. The frequency condition is not intended to require verification of these parameters after every 10% increase in power level above the last verification. It only requires verification after a power level is achieved for extended operation that is 10% higher than the power at which ( , , ) was last measured.

Surveillance Requirement 4.2.2.2.e requires evaluations of the trend in ( , , ), by extrapolation to +31 EFPD beyond the most recent measurement, against ( , , ) and

( , , ) evaluated at +31 EFPD burnup, to account for any increase in ( , , ) that may occur and cause a limit to be exceeded before the next required surveillance. As a result of this evaluation, either limits are reverified with ( , , ) increased by a factor specified in the COLR, or Surveillance Requirement 4.2.2.2.c is repeated prior to the time at which the extrapolated margin becomes zero.

SHEARON HARRIS - UNIT 1 B 3/4 2-4a Amendment No. 171

POWER DISTRIBUTION LIMITS BASES HEAT FLUX HOT CHANNEL FACTOR AND NUCLEAR ENTHALPY RISE HOT CHANNEL FACTOR (Continued)

With ( , , ) exceeding a surveillance limit, certain Required Actions are specified, depending on the limit exceeded, to preserve power distributions assumed in the safety analysis:

  • With ( , , ) exceeding its steady state limit, THERMAL POWER, the Power Range Neutron Flux - High Trip Setting, and the Overpower T Trip Setpoint (K4) are each reduced at least 1% for each 1% ( , , ) exceeds the limit.
  • With ( , , ) exceeding its transient Operational limit ( , , ) , the Power Range Neutron Flux - High Trip Setting and the Overpower T Trip Setpoint (K4) are each reduced at least 1% for each 1% ( , , ) exceeds the limit. AFD limits and THERMAL POWER are reduced by the amounts specified in the COLR.

the Overpower T f2(I) breakpoints are reduced by KSLOPE for each 1% ( , , )

exceeds the limit, where KSLOPE is specified in the COLR.

( , , ) evaluations are not applicable for the following axial core regions, measured in percent of core height:

1. Lower core region from 0 to 10%, inclusive.
2. Upper core region from 90 to 100%, inclusive.

The top and bottom 10% of the core are excluded from the evaluation because of the low probability that these regions would be more limiting in the safety analyses and because of the difficulty of making a precise measurement in these regions.

SHEARON HARRIS - UNIT 1 B 3/4 2-5 Amendment No. 171

POWER DISTRIBUTION LIMITS BASES 3/4.2.4 QUADRANT POWER TILT RATIO The QUADRANT POWER TILT RATIO limit assures that gross changes in the radial power distribution are identified such that the power distribution satisfies the design values used in the safety analysis. Radial power distribution measurements are made during STARTUP testing and periodically during power operation.

The limit of 1.02, at which corrective action is required, provides DNB and linear heat generation rate protection with x-y plane power tilts. The relationship between this limit and a power peaking penalty for thermal limits calculations is determined and subsequently applied in safety analyses.

The 2-hour time allowance for operation with a tilt condition greater than 1.02 but less than 1.09 is provided to allow identification and correction of a dropped or misaligned control rod. In the event such action does not correct the tilt, the margin for uncertainty on FQ is reinstated by reducing the maximum allowed power by 3% for each percent of tilt in excess of 1.02.

For purposes of monitoring QUADRANT POWER TILT RATIO when one excore detector is inoperable, the movable incore detectors are used to confirm that the normalized symmetric power distribution is consistent with the QUADRANT POWER TILT RATIO. The incore detector monitoring is done with a full incore flux map or two sets of four symmetric thimbles. The preferred sets of four symmetric thimbles is a unique set of eight detector locations. These locations are C-8, E-5, E-11, H-3, H-13, L-5, L-11, N-8. If other locations must be used, a special report to NRC should be submitted within 30 days in accordance with 10CFR50.4.

3/4.2.5 DNB PARAMETERS The limits on the DNB-related parameters assure that each of the parameters are maintained within the normal steady-state envelope of operation assumed in the transient and accident analyses. The limits are consistent with the initial FSAR assumptions and have been analytically demonstrated adequate to maintain a minimum DNBR that is equal to or greater than the design DNBR value throughout each analyzed transient. The indicated Tavg value and the indicated pressurizer pressure value are compared to the analytical limits specified in the COLR.

When RCS flow rate is measured, an additional allowance is necessary prior to comparison with the limit of Specification 3.2.5.c. Specifically for the precision calorimetric heat balance, a normal RCS flow rate error of 2.1% will be included.

Potential fouling of the feedwater venturi, which might not be detected, could bias the result from the precision heat balance in a non-conservative manner. Therefore, a penalty of 0.1% for undetected fouling of the feedwater venturi, raises the nominal flow measurement allowance to 2.2% for no venturi fouling. Any fouling which might bias the RCS flow rate measurement greater than 0.1% can be detected by monitoring and trending various plant parameters.

Revision 1 SHEARON HARRIS - UNIT 1 B 3/4 2-6 Amendment No. 171

POWER DISTRIBUTION LIMITS BASES 3/4.2.5 DNB PARAMETERS (Continued)

If detected, action shall be taken before performing subsequent precision heat balance measurements, i.e. either the effect of the fouling shall be quantified and compensated for in the RCS flow rate measurement or the venturi shall be cleaned to eliminate the fouling.

Surveillance 4.2.5.1 ensures that temperature and pressure parameters, through instrument readout, are restored within their respective limits following load changes and other expected transient operation. The periodic surveillance of indicated RCS flow is intended to detect flow degradation.

Surveillance 4.2.5.2 allows entry into MODE 1, without having performed the surveillance, and placement of the unit in the best condition for performing the surveillance. Measurement of RCS flow rate by performance of a precision calorimetric heat balance allows the installed RCS flow instrumentation to be calibrated and verifies that the actual RCS flow rate is greater than or equal to the minimum required RCS flow rate. The surveillance frequency is controlled under the Surveillance Frequency Control Program and reflects the importance of verifying flow following a refueling outage, where work activities were performed that could affect RCS flow. Performance of a precision calorimetric at other times are unnecessary unless changes were introduced that would substantially reduce RCS flow and are likely to produce non-conservative results. The surveillance requirement to perform the precision calorimetric within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> after exceeding 95% RTP is intended to stress the importance of collecting plant flow data as soon as practical after reaching a stable power level that is sufficient for performing the test and in recognition that some plants have experienced feedwater venturi fouling and other phenomena that are more probable as time elapses. If the precision calorimetric data can not be collected in the required time period, it is necessary to reduce power to less than 95% RTP until preparations are complete for collecting precision calorimetric data. Reducing power to less than 95%, resets the allowable time period requirement to perform the precision calorimeter within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> after exceeding 95%

RTP.

SHEARON HARRIS - UNIT 1 B 3/4 2-6a Amendment No. 154

3/4.3 INSTRUMENTATION BASES 3/4.3.1 AND 3/4.3.2 REACTOR TRIP SYSTEM INSTRUMENTATION AND ENGINEERED SAFETY FEATURES ACTUATION SYSTEM INSTRUMENTATION The OPERABILITY of the Reactor Trip System and the Engineered Safety Features Actuation System instrumentation and interlocks ensures that: (1) the associated ACTION and/or Reactor trip will be initiated when the parameter monitored by each channel or combination thereof reaches its Setpoint (2) the specified coincidence logic and sufficient redundancy is maintained to permit a channel to be out-of-service for testing or maintenance consistent with maintaining an appropriate level of reliability of the Reactor Trip System and Engineered Safety Features Actuation System instrumentation, and (3) sufficient system functional capability is available from diverse parameters.

The OPERABILITY of these systems is required to provide the overall reliability, redundancy, and diversity assumed available in the facility design for the protection and mitigation of accident and transient conditions. The integrated operation of each of these systems is consistent with the assumptions used in the safety analyses. The Surveillance Requirements specified for these systems ensure that the overall system functional capability is maintained comparable to the original design standards. The periodic surveillance tests are sufficient to demonstrate this capability. Surveillance intervals have been determined in accordance with the Surveillance Frequency Control Program and surveillance and maintenance outage times have been determined in accordance with WCAP-10271, "Evaluation of Surveillance Frequencies and Out of Service Times for the Reactor Protection Instrumentation System," and supplements to that report as approved by the NRC and documented in the SERs and SSER (letters to J. J. Sheppard from Cecil O. Thomas dated February 21, 1985; Roger A. Newton from Charles E. Rossi dated February 22, 1989; and Gerard T. Goering from Charles E. Rossi dated April 30, 1990).

The Engineered Safety Features Actuation System Instrumentation Trip Setpoints specified in Table 3.3-4 are the nominal values at which the bistables are set for each functional unit. A Setpoint is considered to be adjusted consistent with the nominal value when the "as measured" Setpoint is within the band allowed for calibration accuracy. For example, if a bistable has a trip setpoint of 100%, a span of 125%, and a calibration accuracy of +/-0.50%, then the bistable is considered to be adjusted to the trip setpoint as long as the "as measured" value for the bistable is 100.62%.

To accommodate the instrument drift assumed to occur between operational tests and the accuracy to which Setpoints can be measured and calibrated, Allowable Values for the Setpoints have been specified in Table 3.3-4. Operation with Setpoints less conservative than the Trip Setpoint but within the Allowable Value is acceptable since an allowance has been made in the safety analysis to accommodate this error. An optional provision has been included for determining the OPERABILITY of a channel when its Trip Setpoint is found to exceed the Allowable Value. The methodology of this option utilizes the "as measured" deviation from the specified calibration point for rack and sensor components in conjunction with a statistical combination of the other uncertainties of the instrumentation to measure the process variable and the uncertainties in calibrating the instrumentation. In Equation 3.3-1, Z + R + S TA, the interactive effects of the errors in the rack and the sensor, and the "as measured" values of the errors are considered. Z, as specified in Table 3.3-4, in percent span, is the statistical summation of errors assumed in the analysis excluding those associated with the sensor and rack drift and the accuracy of their measurement. TA or Total Allowance is the difference, in percent span, between the trip setpoint and the value used in the analysis for the actuation. R or Rack Error is the "as measured" deviation, in the percent span, for the affected channel from the specified Trip Setpoint. S or Sensor Error is either the "as measured" deviation of the sensor from its calibration point or the value specified in Table 3.3-4, in percent span, from the analysis assumptions. Use of Equation 3.3-1 allows for a sensor draft factor, an increased rack drift factor, and provides a SHEARON HARRIS - UNIT 1 B 3/4 3-1 Amendment No. 154

3/4.3 INSTRUMENTATION BASES threshold value for determination of OPERABILITY.

The methodology to derive the Trip Setpoints is based upon combining all of the uncertainties in the channels. Inherent to the determination of the Trip Setpoints are the magnitudes of these channel uncertainties. Sensor and rack instrumentation utilized in these channels are expected to be capable of operating within the allowances of these uncertainty magnitudes. Rack drift in excess of the Allowable Value exhibits the behavior that the rack has not met its allowance. Being that there is a small statistical chance that this will happen, an infrequent excessive drift is expected. Rack or sensor drift, in excess of the allowance that is more than occasional, may be indicative of more serious problems and should warrant further investigation.

Engineered Safety Features Actuation System Instrumentation Trip Setpoints and TSTF-493-A, Option A This section applies only to the Functional Units to which Notes 1 and 2 in the Trip Setpoint Column are applicable. Those Functional Units have revisions in accordance with Technical Specification Task Force Traveler 493-A (TSTF-493-A), Revision 4, Clarify Application of Setpoint Methodology for LSSS Functions, Option A. Those Functional Units are limited to Functional Unit 6.e, Auxiliary Feedwater, Loss of Offsite Power Start Motor-Driven Pumps and Turbine-Driven Pumps. Because HNP TS Table 3.3-4, Functional Unit 6.e refers to TS Table 3.3-4, Item 9 for all Loss-of-Offsite Trip Setpoint and Allowable Values, the two Notes are applied to TS Table 3.3-4, Functional Unit 9.a.

Notes 1 and 2 have been added to Table 3.3-4 that require verifying both trip setpoint setting as-found and as-left values during surveillance testing. In accordance with 10 CFR 50.36, these functions are Limiting Safety System Settings. Adding test requirements ensures that instruments will function as required to initiate protective systems or actuate mitigating systems at the point assumed in the applicable safety analysis. These notes address NRC staff concerns with Technical Specification Allowable Values. Specifically, calculated Allowable Values may be non-conservative depending upon the evaluation of instrument performance history, and the as-left requirements of the calibration procedures could have an adverse effect on equipment operability. In addition, using Allowable Values as the limiting setting for assessing instrument channel operability may not be fully in compliance with the intent of 10 CFR 50.36, and the existing surveillance requirements would not provide adequate assurance that instruments will always actuate safety functions at the point assumed in the applicable safety analysis. In the Harris Technical Specifications, the term Trip Setpoint is analogous to Nominal Trip Setpoint (NTSP) in TSTF-493-A, Option A.

Note 1 requires a channel performance evaluation when the as-found setting is outside its as-found tolerance. The performance evaluation verifies that the channel will continue to behave in accordance with safety analysis and instrument performance assumptions in the setpoint methodology. The purpose of this evaluation is to provide confidence in the performance prior to returning the channel to service. If the as-found setting is non-conservative with respect to the Allowable Value, the channel is inoperable. If the as-found setting is conservative with respect to the Allowable Value but is outside the as-found tolerance band, the channel is OPERABLE but degraded. The degraded channel condition will be further evaluated during performance of the surveillance. This evaluation will consist of resetting the channel setpoint to within the as-left tolerances applicable to the actual setpoint implemented in the surveillance procedures (field setting), and evaluating the channel response. If the channel is functioning as required and is expected to pass the next surveillance, then the channel is OPERABLE and can be restored to service at the completion of the surveillance. After the surveillance is completed, the channel as-found condition is entered into the corrective action program for further analysis and trending.

SHEARON HARRIS - UNIT 1 B 3/4 3-2 Amendment No. 146

3/4.3 INSTRUMENTATION BASES Note 2 requires that the as-left channel setting be reset to a value that is within the as-left tolerances about the Trip Setpoint in Table 3.3-4 or within as-left tolerances about a more conservative actual (field) setpoint. As-left channel settings outside the as-left tolerances of PLP-106 and the surveillance procedures cause the channel to be INOPERABLE.

A tolerance is necessary because no device perfectly measures the process. Additionally, it is not possible to read and adjust a setting to an absolute value due to the readability and/or accuracy of the test instruments or the ability to adjust potentiometers. The as-left tolerance is considered in the setpoint calculation. Failure to set the actual plant trip setpoint to within as-left the tolerances of the NTSP or within as-left tolerances of a more conservative actual field setpoint would invalidate the assumptions in the setpoint calculation, because any subsequent instrument drift would not start from the expected as-left setpoint. The determination will consider whether the instrument is degraded or is capable of being reset and performing its specified safety function.

If the channel is determined to be functioning as required (i.e., the channel can be adjusted to within the as-left tolerance and is determined to be functioning normally based on the determination performed prior to returning the channel to service), then the channel is OPERABLE and can be restored to service. If the as-left instrument setting cannot be returned to a setting within the prescribed as-left tolerance band, the instrument would be declared inoperable.

The methodologies for calculating the as-found tolerances and as-left tolerances about the Trip Setpoint or more conservative actual field setpoint are specified in EGR-NGGC-0153, Engineering Instrument Setpoints, which is incorporated by reference into the FSAR. The actual field setpoint and the associated as-found and as-left tolerances are specified in PLP-106, the applicable section of which is incorporated by reference into the FSAR.

Limiting Trip Setpoint (LTSP) is generic terminology for the setpoint value calculated by means of the setpoint methodology documented in EGR-NGGC-0153. HNP uses the plant-specific term NTSP in place of the generic term LTSP. The NTSP is the LTSP with margin added, and is always equal to or more conservative than the LTSP. The NTSP may use a setting value that is more conservative than the LTSP, but for Technical Specification compliance with 10 CFR 50.36, the plant-specific setpoint term NTSP is cited in Note 2. The NTSP meets the definition of a Limiting Safety System Setting per 10 CFR 50.36 and is a predetermined setting for a protective channel chosen to ensure that automatic protective actions will prevent exceeding Safety Limits during normal operation and design basis anticipated operational occurrences, and assist the Engineered Safety Features Actuation System in mitigating the consequences of accidents. The Allowable Value is the least conservative value of the as-found setpoint that the channel can have when tested, such that a channel is OPERABLE if the as-found setpoint is within the as-found tolerance and is conservative with respect to the Allowable Value during a CHANNEL CALIBRATION or CHANNEL OPERATIONAL TEST. As such, the Allowable Value differs from the NTSP by an amount greater than or equal to the expected instrument channel uncertainties, such as drift, during the surveillance interval. In this manner, the actual NTSP setting ensures that a Safety Limit is not exceeded at any given point of time as long as the channel has not drifted beyond expected tolerances during the surveillance interval. Although the channel is OPERABLE under these circumstances, the trip setpoint must be left adjusted to a value within the as-left tolerance band, in accordance with uncertainty assumptions stated in the setpoint methodology (as-left criteria), and confirmed to be operating within the statistical allowances of the uncertainty terms assigned (as-found criteria).

Field setting is the term used for the actual setpoint implemented in the plant surveillance procedures, where margin has been added to the calculated field setting. The as-found and as-left tolerances apply to the field settings implemented in the surveillance procedures to confirm SHEARON HARRIS - UNIT 1 B 3/4 3-2a Amendment No. 161

3/4.3 INSTRUMENTATION BASES channel performance. A trip setpoint may be set more conservative than the NTSP as necessary in response to plant conditions. However, in this case, the instrument operability must be verified based on the field setting and not the NTSP.

The measurement of response time at the frequencies specified in the Surveillance Frequency Control Program provides assurance that the reactor trip and the Engineered Safety Features actuation associated with each channel is completed within the time limit assumed in the safety analyses. No credit was taken in the analyses for those channels with response times indicated as not applicable. Response time may be demonstrated by any series of sequential, overlapping, or total channel test measurements provided that such tests demonstrate the total channel response time as defined. Response time may be verified by actual response time tests in any series of sequential, overlapping or total channel measurements; or by the summation of allocated sensor, signal processing and actuation logic response times with actual response time tests on the remainder of the channel. Allocations for sensor response times may be obtained from: (1) historical records based on acceptable response time tests (hydraulic, noise or power interrupt tests); (2) inplace, onsite, or offsite (e.g., vendor) test measurements; or (3) utilizing vendor engineering specifications. WCAP-13632-P-A, Rev. 2, "Elimination of Pressure Sensor Response Time Testing Requirements," provides the basis and methodology for using allocated sensor response times in the overall verification of the channel response time for specific sensors identified in the WCAP. Response time verification for other sensor types must be demonstrated by test.

WCAP 14036-P-A, Rev. 1, "Elimination of Periodic Response Time Tests," provides the basis and methodology for using allocated signal processing and actuation logic response times in the overall verification of the protection system channel response time. The allocations for sensor, signal conditioning, and actuation logic response times must be verified prior to placing the component into operational service and re-verified following maintenance or modification that may adversely affect response time. In general, electrical repair work does not impact response time provided the parts used for the repair are the same type and value. Specific components identified in the WCAP may be replaced without verification testing. One example where response time could be affected is replacing the sensing element of a transmitter.

The Engineered Safety Features Actuation System senses selected plant parameters and determines whether or not predetermined limits are being exceeded. If they are, the signals are combined into logic matrices sensitive to combinations indicative of various accidents events, and transients. Once the required logic combination is completed, the system sends actuation signals to those Engineered Safety Features components whose aggregate function best serves the requirements of the condition. As an example, the following actions may be initiated by the Engineered Safety Features Actuation System to mitigate the consequences of a steam line break or loss-of-coolant accident: (1) charging/safety injection pumps start and automatic valves position, (2) reactor trip, (3) feedwater isolation, (4) startup of the emergency diesel generators, (5) containment spray pumps start and automatic valves position (6) containment isolation, (7) steam line isolation, (8) turbine trip, (9) auxiliary feedwater pumps start and automatic valves position, (10) containment fan coolers start and automatic valves position, (11) emergency service water pumps start and automatic valves position, and (12) control room isolation and emergency filtration start.

SHEARON HARRIS - UNIT 1 B 3/4 3-2b Amendment No. 154

3/4.3 INSTRUMENTATION BASES Table 3.3-4 includes values for 6.9 kV Emergency Bus Undervoltage - Secondary (degraded grid) trip setpoints and allowable values. The secondary undervoltage relays are connected to two distinct time delay relays. Upon expiration of the first time delay, which is long enough to accommodate the starting of the motor which has the longest starting time, an alarm is actuated at the main control board to alert the operator of this condition and to permit operator actions to restore the system voltage. Automatic tripping actions as described for the primary protection are initiated if a safety actuation signal is present after the expiration of the time delay.

In the event of a coincident large break loss of coolant accident (LBLOCA) and voltage dropping to actuate the short-term DVR function (bus voltage drops into the range between the DVR dropout voltage setting and the loss of offsite power voltage setpoint), a safety injection actuation signal is generated, emergency loads begin to sequence onto the emergency buses (still powered from the normal offsite supply), and the emergency diesel generator starts but does not load. If the degraded voltage condition continues to exist until the short-term DVR time delay setting is reached, the emergency loads are then separated from offsite power, loads on emergency buses are shed, the emergency diesel generator output breaker is shut, and the emergency loads are sequenced back onto the emergency buses. The LBLOCA analysis timeline for the safety functions provided by the equipment in this scenario is used to establish the analytical limit for the maximum short-term DVR time delay. This meets the intent of Branch Technical Position PSB-1 regarding maximum time delays consistent with design basis accident analysis.

If degraded voltage conditions exist without a simultaneous accident (normal operating conditions), a longer time delay (Device 2-2) is allowed before the automatic tripping actions are initiated. This second time delay is based on the maximum time for which the most sensitive load can perform its safety function without impairment at the degraded voltage.

Calculations to determine time delay allowable values and trip setpoints to protect time delay analytical limits were performed consistent with the methodology of Technical Specification Task Force Traveler 493, Clarify Application of Setpoint Methodology for LSSS Functions. Although the DVR function is not a limiting safety system setting function, the methodology is a conservative approach for determination of these parameters.

The Engineered Safety Features Actuation System interlocks perform the following functions:

P-4 Reactor tripped - Actuates Turbine trip, closes main feedwater valves on Tavg below Setpoint, prevents the opening of the main feedwater valves which were closed by a Safety Injection or High Steam Generator Water Level signal, allows Safety Injection block so that components can be reset or tripped.

Reactor not tripped - prevents manual block of Safety Injection.

P-11 On increasing pressurizer pressure, P-11 automatically reinstates Safety Injection actuation on low pressurizer pressure and low steam-line pressure, sends an open signal to the accumulator discharge valves and automatically blocks steam-line isolation on a high rate of decrease in steam-line pressure. On decreasing pressurizer pressure, P-11 allows the manual block of Safety Injection on low pressurizer pressure and low steam-line pressure and allows steam-line isolation, on a high rate of decrease in steam-line pressure, to become active upon manual block of Safety Injection from low steam-line pressure.

P-12 P-12 has no ESF or reactor trip functions. On decreasing reactor coolant loop temperature, P-12 automatically removes the arming signal from the Steam Dump System.

SHEARON HARRIS - UNIT 1 B 3/4 3-3 Amendment No. 143

3/4.3 INSTRUMENTATION BASES P-14 On increasing steam generator water level, P-14 automatically trips all feedwater isolation valves and inhibits feedwater control valve modulation.

3/4.3.3 MONITORING INSTRUMENTATION 3/4.3.3.1 RADIATION MONITORING FOR PLANT OPERATIONS The OPERABILITY of the radiation monitoring instrumentation for plant operations ensures that:

(1) the associated action will be initiated when the radiation level monitored by each channel or combination thereof reaches its setpoint, (2) the specified coincidence logic is maintained, and (3) sufficient redundancy is maintained to permit a channel to be out-of-service for testing or maintenance. The radiation monitors for plant operations senses radiation levels in selected plant systems and locations and determines whether or not predetermined limits are being exceeded. If they are, the signals are combined into logic matrices sensitive to combinations indicative of various accidents and abnormal conditions. Once the required logic combination is completed, the system sends actuation signals to initiate alarms or automatic isolation action and actuation of emergency systems.

3/4.3.3.2 DELETED 3/4.3.3.3 DELETED 3/4.3.3.4 DELETED 3/4.3.3.5 REMOTE SHUTDOWN SYSTEM The OPERABILITY of the Remote Shutdown System ensures that sufficient capability is available to permit safe shutdown of the facility from locations outside of the control room. This capability is required in the event control room habitability is lost and is consistent with General Design Criterion 19 of 10 CFR Part 50.

The OPERABILITY of the Remote Shutdown System ensures that a fire will not preclude achieving safe shutdown. The Remote Shutdown System instrumentation, control, and power circuits and transfer switches necessary to eliminate effects of the fire and allow operation of instrumentation, control and power circuits required to achieve and maintain a safe shutdown condition are independent of areas where a fire could damage systems normally used to shut down the reactor.

This capability is consistent with General Design Criterion 3, 10 CFR 50.48(a) and 10 CFR 50.48(c).

3/4.3.3.6 ACCIDENT MONITORING INSTRUMENTATION The OPERABILITY of the accident monitoring instrumentation ensures that sufficient information is available on selected plant parameters to monitor and assess these variables following an accident. This capability is consistent with the recommendations of Regulatory Guide 1.97, Revision 3, "Instrumentation for Light-Water-Cooled Nuclear Power Plants to Assess Plant Conditions During and Following an Accident," May 1983 and NUREG-0737, "Clarification of TMI Action Plan Requirements," November 1980. The RVLIS and In Core Thermocouple design meets the intent of Regulatory Guide 1.97. The HNP design (and Regulatory Guide 1.97) stipulates redundancy for RVLIS and In Core Thermocouples. A fully 100% functional channel would be available should a channel fail.

The RVLIS and In Core Thermocouple systems do not automatically actuate any component.

These monitoring systems are used for indication only. Diverse monitoring is available for core cooling indication requirements such as Reactor Coolant Hot and Cold Leg temperature SHEARON HARRIS - UNIT 1 B 3/4 3-4 Amendment No. 143

3/4.3 INSTRUMENTATION BASES indications as well as Reactor Coolant System pressure.

The thirty-day completion time for one inoperable channel of RVLIS or In Core Thermocouples is based on operating experience and takes into account the remaining OPERABLE channel, the passive nature of the instrument (no critical automatic action is assumed to occur from these instruments), and the low probability of an event requiring an instrument during this interval. If the thirty-day completion time was not met, then a written report to the NRC would be required to outline the preplanned alternate method of monitoring (in this case the other redundant channel would be available), the cause of the inoperability, and plans and a schedule for restoring the instrumentation channels of the Function to operable status.

If both channels of RVLIS or In Core Thermocouples are inoperable, then restore an inoperable channel within 7 days. The completion time of 7 days is based on the relatively low probability of an event requiring RVLIS and In Core Thermocouple instrumentation operation and the availability of alternate means to obtain the required information. Diverse monitoring is available for core cooling indication requirements such as Reactor Coolant Hot and Cold Leg temperature indications as well as Reactor Coolant System pressure. These parameters can be used to manually determine subcooling margin, which normally uses core exit temperatures.

3/4.3.3.7 DELETED 3/4.3.3.8 DELETED 3/4.3.3.9 DELETED 3/4.3.3.10 DELETED 3/4.3.3.11 DELETED 3/4.3.4 DELETED SHEARON HARRIS - UNIT 1 B 3/4 3-5 Amendment No. 143

3/4.4 REACTOR COOLANT SYSTEM BASES 3/4.4.1 REACTOR COOLANT LOOPS AND COOLANT CIRCULATION The plant is designed to operate with all reactor coolant loops in operation and maintain DNBR above the design DNBR value during all normal operations and anticipated transients. In MODES 1 and 2 with one reactor coolant loop not in operation this specification requires that the plant be in at least HOT STANDBY within 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

In MODE 3, two reactor coolant loops provide sufficient heat removal capability for removing core decay heat even in the event of a bank withdrawal accident; however, a single reactor coolant loop provides sufficient heat removal capacity if a bank withdrawal accident can be prevented, i.e., by opening the Reactor Trip System breakers. Single failure considerations require that two loops be OPERABLE at all times.

In MODE 4, and in MODE 5 with reactor coolant loops filled, a single reactor coolant loop or RHR loop provides sufficient heat removal capability for removing decay heat; but single failure considerations require that at least two loops (either RHR or RCS) be OPERABLE.

Surveillance Requirements for MODES 3, 4, and 5 with reactor coolant loops filled require verification of steam generator (SG) OPERABILITY. Verification of adequate level in the applicable steam generator ensures an adequate heat sink for the removal of decay heat. If the SG tubes become uncovered, the associated loop may not be capable of providing the heat sink for the removal of the decay heat. The level values include allowances for channel uncertainty and process measurement effects and may not be simultaneously indicated by the respective instrumentation. The surveillance frequency is controlled under the Surveillance Frequency Control Program.

In MODE 5 with reactor coolant loops not filled, a single RHR loop provides sufficient heat removal capability for removing decay heat; but single failure considerations, and the unavailability of the steam generators as a heat removing component, require that at least two RHR loops be OPERABLE.

The operation of one reactor coolant pump (RCP) or one RHR pump provides adequate flow to ensure mixing, prevent stratification and produce gradual reactivity changes during boron concentration reductions in the Reactor Coolant System. The reactivity change rate associated with boron reduction will, therefore, be within the capability of operator recognition and control.

The restrictions on starting an RCP with one or more RCS cold legs less than or equal to 325°F are provided to prevent RCS pressure transients, caused by energy additions from the Secondary Coolant System, which could exceed the limits of Appendix G to 10 CFR Part 50. The RCS will be protected against overpressure transients and will not exceed the limits of Appendix G by restricting starting of the RCPs to when the secondary water temperature of each steam generator is less than 50°F above each of the RCS cold leg temperatures.

Management of gas voids is important to RHR System OPERABILITY. RHR System piping and components have the potential to develop voids and pockets of entrained gases. Preventing and managing gas intrusion and accumulation is necessary for proper operation of the required RHR loop(s) and may also prevent water hammer, pump cavitation, and pumping of noncondensible gas into the reactor vessel.

Surveillance Requirements verify that required RHR loop locations susceptible to gas accumulation are sufficiently filled with water. Selection of RHR System locations susceptible to gas accumulation is based on a review of system design information, including piping and instrumentation drawings, isometric drawings, plan and elevation drawings, and calculations. The design review is supplemented by system walk downs to validate the system high points and to SHEARON HARRIS - UNIT 1 B 3/4 4-1 Amendment No. 154

REACTOR COOLANT SYSTEM BASES REACTOR COOLANT LOOPS AND COOLANT CIRCULATION (Continued) confirm the location and orientation of important components that can become sources of gas or could otherwise cause gas to be trapped or difficult to remove during system maintenance or restoration. Susceptible locations depend on plant and system configuration, such as stand-by versus operating conditions.

The RHR System is OPERABLE when it is sufficiently filled with water. Acceptance criteria are established for the volume of accumulated gas at susceptible locations. If accumulated gas is discovered that exceeds the acceptance criteria for the susceptible location (or the volume of accumulated gas at one or more susceptible locations exceeds an acceptance criteria for gas volume at the suction or discharge of a pump), the Surveillance is not met. If it is determined by subsequent evaluation that the RHR System is not rendered inoperable by the accumulated gas (i.e., the system is sufficiently filled with water), the Surveillance may be declared met.

Accumulated gas should be eliminated or brought within the acceptance criteria limits. If any accumulated gas is eliminated or brought within the acceptance criteria limits as part of the Surveillance performance, the Surveillance is considered met and the system is OPERABLE.

Past operability is then evaluated under the Corrective Action program. If it is suspected that a gas intrusion event is occurring, then this is evaluated under the Operability Determination Process.

RHR System locations susceptible to gas accumulation are monitored and, if gas is found, the gas volume is compared to the acceptance criteria for the location. Susceptible locations in the same system flow path which are subject to the same gas intrusion mechanisms may be verified by monitoring a representative sub-set of susceptible locations. Monitoring may not be practical for locations that are inaccessible due to radiological or environmental conditions, the plant configuration, or personnel safety. For these locations alternative methods (e.g., operating parameters, remote monitoring) may be used to monitor the susceptible location. Monitoring is not required for susceptible locations where the maximum potential accumulated gas void volume has been evaluated and determined to not challenge system OPERABILITY. The accuracy of the method used for monitoring the susceptible locations and trending of the results should be sufficient to assure system OPERABILITY during the Surveillance interval.

Surveillance Requirement 4.4.1.3.4 is modified by a Note that states the SR is not required to be performed until 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> after entering MODE 4. In a rapid shutdown, there may be insufficient time to verify all susceptible locations prior to entering MODE 4.

3/4.4.2 SAFETY VALVES The pressurizer Code safety valves operate to prevent the RCS from being pressurized above its Safety Limit of 2735 psig. Each safety valve is designed to relieve 380,000 lbs per hour of saturated steam at the valve Setpoint. The relief capacity of a single safety valve is adequate to relieve any SHEARON HARRIS - UNIT 1 B 3/4 4-1a Amendment No. 150

REACTOR COOLANT SYSTEM BASES SAFETY VALVES (Continued) overpressure condition which could occur during shutdown. In the event that no safety valves are OPERABLE, an operating RHR loop, connected to the RCS, provides overpressure relief capability and will prevent RCS overpressurization. In addition, the Overpressure Protection System provides a diverse means of protection against RCS overpressurization at low temperatures.

During operation, all pressurizer Code safety valves must be OPERABLE to prevent the RCS from being pressurized above its Safety Limit of 2735 psig. The combined relief capacity of all of these valves is greater than the maximum surge rate resulting from a complete loss-of-load assuming no reactor trip until the second Reactor Trip System trip setpoint is reached (i.e., no credit is taken for a direct Reactor trip on the loss-of-load) and also assuming no operation of the power-operated relief valves or steam dump valves.

Demonstration of the safety valves' lift settings will occur only during shutdown and will be performed in accordance with the provisions of Section XI of the ASME Boiler and Pressure Code.

3/4.4.3 PRESSURIZER In MODES 1, 2 and 3 the LCO requirement for a steam bubble is reflected implicitly in the accident analyses. Safety analyses performed for lower MODES are not limiting. All analyses performed from a critical reactor condition assume the existence of a steam bubble and saturated conditions in the pressurizer. In making this assumption, the analyses neglect the small fraction of non-condensable gases normally present. Safety analyses presented in the FSAR do not take credit for pressurizer heater operation; however, an implicit initial condition assumption of the safety analyses is that the RCS is operating at normal pressure. The maximum pressurizer water level limit, which ensures that a steam bubble exists in the pressurizer, is an initial condition for the RCS overpressurization that occurs during Turbine Trip in MODE 1. The initial pressurizer water level for other FSAR events is in accordance with applicable methodologies. This satisfies Criterion 2 of 10 CFR 50.36(c)(2)(ii). Although the heaters are not specifically used in accident analysis, the need to maintain subcooling in the long term during loss of offsite power, as indicated in NUREG-0737, is the reason for providing an LCO.

3/4.4.4 RELIEF VALVES In MODES 1, 2, and 3 the power-operated relief values (PORVs) provide an RCS pressure boundary, manual RCS pressure control for mitigation of accidents, and automatic RCS pressure relief to minimize challenges to the safety valves.

Providing an RCS pressure boundary and manual RCS pressure control for mitigation of a steam generator tube rupture (SGTR) are the safety-related functions of the PORVs in MODES 1, 2, and

3. The capability of the PORV to perform its function of providing an RCS pressure boundary requires that the PORV or its associated block valve is closed. The capability of the PORV to perform manual RCS pressure control for mitigation of a SGTR accident is based on manual actuation and does not require the automatic RCS pressure control function. The automatic RCS pressure control function of the PORVs is not a safety-related function in MODES 1, 2, and 3. The automatic pressure control function limits the number of challenges to the safety valves, but the safety valves perform the safety function of RCS overpressure protection. Therefore, the automatic RCS pressure control function of the PORVs does not have to be available for the PORVs to be operable.

SHEARON HARRIS - UNIT 1 B 3/4 4-2 Amendment No. 151

REACTOR COOLANT SYSTEM BASES RELIEF VALVES (Continued)

Each PORV has a remotely operated block valve to provide a positive shutoff capability should a relief valve become inoperable. Operation with the block valves opened is preferred. This allows the PORVs to perform automatic RCS pressure relief should the RCS pressure actuation setpoint be reached. However, operation with the block valve closed to isolate PORV seat leakage is permissible since automatic RCS pressure relief is not a safety-related function of the PORVs.

The OPERABILITY of the PORVs and block valves in MODES 1, 2, and 3 is based on their being capable of performing the following functions:

1. Maintaining the RCS pressure boundary,
2. Manual control of PORVs to control RCS pressure as required for SGTR mitigation,
3. Manual closing of a block valve to isolate a stuck open PORV,
4. Manual closing of a block valve to isolate a PORV with excessive seat leakage, and
5. Manual opening of a block valve to unblock an isolated PORV to allow it to be used to control RCS pressure for SGTR mitigation.

The non-safety PORV and block valve are used only as a backup to the two redundant safety grade PORVs and block valves to control RCS pressure for accident mitigation. Therefore, continued operation with the non-safety PORV unavailable for RCS pressure control is allowed as long as the block valve or PORV can be closed to maintain the RCS pressure boundary.

Surveillance Requirements provide the assurance that the PORVs and block valves can perform their safety functions. Surveillance Requirements 4.4.4.1 and 4.4.4.3 address the PORVs and Surveillance Requirement 4.4.4.2 addresses the block valves. The surveillance frequencies are controlled under the Surveillance Frequency Control Program.

Surveillance Requirements 4.4.4.1.a provides assurance the actuation instrumentation for automatic PORV actuation is calibrated such that the automatic PORV actuation signal is within the required pressure range even though automatic actuation capability of the PORV is not necessary for the PORV to be OPERABLE in MODES 1, 2, and 3.

Surveillance Requirement 4.4.4.1.b provides assurance the PORV is capable of opening and closing. The associated block valve should be closed prior to stroke testing a PORV to preclude depressurization of the RCS. This test will be done in MODES 3 or 4, before the PORV is required for overpressure protection in TS 3.4.9.4.

SHEARON HARRIS - UNIT 1 B 3/4 4-2a Amendment No. 154

REACTOR COOLANT SYSTEM BASES RELIEF VALVES (Continued)

Surveillance Requirements 4.4.4.3 provides assurance of operability of the accumulators and that the accumulators are capable of supplying sufficient air to operate PORV(s) if they are needed for RCS pressure control and normal air and nitrogen systems are not available.

Surveillance Requirements 4.4.4.2 addresses the block valves. The block valves are exempt from the surveillance requirements to cycle the valves when they have been closed to comply with ACTION statements "b" or "c". This precludes the need to cycle the valves with a full system differential pressure or when maintenance is being performed to restore an inoperable PORV to OPERABLE status.

3/4.4.5 STEAM GENERATOR (SG)TUBE INTEGRITY

Background

Steam generator (SG) tubes are small diameter. thin walled tubes that carry primary coolant through the primary-to-secondary heat exchangers. The SG tubes have a number of important safety functions. SG tubes are an integral part of the reactor coolant pressure boundary CRCPB) and. as such. are relied on to maintain the primary system's pressure and inventory. The SG tubes isolate the radioactive fission products in the primary coolant from the secondary system.

In addition. as part of the RCPB. the SG tubes are unique in that they act as the heat transfer surface between the primary and secondary systems to remove heat from the primary system. This specification addresses only the RCPB integrity function of the SG. The SG heat removal function is addressed by LCO 3.4.1.1. "Reactor Coolant Loops and Coolant Circulation. Startup and Power Operation." LCO 3.4.1.2. "Reactor Coolant System. Hot Standby," LCO 3.4.1.3.

"Reactor Coolant System. Hot Shutdown." and LCO 3.4.1.4.1. "Reactor Coolant System. Cold Shutdown-Loops Filled."

SG tube integrity means that the tubes are capable of performing their intended RCPB safety function consistent with the licensing basis. including applicable regulatory requirements.

SHEARON HARRIS - UNIT 1 B 3/4 4-2b Amendment No. 124

REACTOR COOLANT SYSTEM BASES 3/4.4.5 STEAM GENERATOR (SG) TUBE INTEGRITY (continued)

SG tubing is subject to a variety of degradation mechanisms. SG tubes may experience tube degradation related to corrosion phenomena. such as wastage.

pitting. intergranular attack. and stress corrosion cracking. along with other mechanically induced phenomena such as denting and wear. These degradation mechanisms can impair tube integrity if they are not managed effectively. The SG performance criteria are used to manage SG tube degradation.

Specification 6.8.4.1. "Steam Generator Program." requires that a program be established and implemented to ensure that SG tube integrity is maintained.

Pursuant to Specification 6.8.4.1. tube integrity is maintained when the SG performance criteria are met. There are three SG performance criteria:

structural integrity. accident induced leakage. and operationalleakage. The SG performance criteria are described in Specification 6.8.4.1. Meeting the SG performance criteria provides reasonable assurance of maintaining tube integrity at normal and accident conditions.

The processes used to meet the SG performance criteria are defined by the Steam Generator Program Guidelines (Reference 12.

SHEARON HARRIS - UNIT 1 B 3/4 4-2c Amendment No. 124

REACTOR COOLANT SYSTEM BASES 3/4.4.5 STEAM GENERATOR (SG) TUBE INTEGRITY (continued)

Applicable Safety Analyses The steam generator tube rupture (SGTR) accident is the limiting design basis event for SG tubes and avoiding an SGTR is the basis for this specification. The analysis of a SGTR event assumes a bounding primary-to-secondary leakage rate equal to 1 gallon per minute (gpm), plus the leakage rate associated with a double-ended rupture of a single tube. The accident radiological analysis for a SGTR assumes the ruptured SG secondary fluid is released directly to the atmosphere due to a failure of the PORV in the open position.

The analysis for design basis accidents and transients other than a SGTR assume the SG tubes retain their structural integrity (i.e., they are assumed not to rupture). In some analyses developed by the industry, the steam discharge to the atmosphere is based on the total primary-to-secondary leakage from all SGs of 1 gpm, or is assumed to increase to 1 gpm as a result of accident induced conditions. The HNP accident analyses assume the amount of primary-to-secondary SG tube leakage is 1 gpm. For accidents that do not involve fuel damage, the primary coolant activity level of DOSE EQUIVALENT I-131 is assumed to be equal to the limits in LCO 3.4.8, "Reactor Coolant System Specific Activity." For accidents that assume fuel damage, the primary coolant activity is a function of the amount of activity released from the damaged fuel. The dose consequences of these events are within the limits of 10 CFR 50.67 (Reference 2).

SG tube integrity satisfies Criterion 2 of 10 CFR 50.36(c)(2)(ii).

Limiting Condition for Operation (LCO)

The LCO requires that SG tube integrity be maintained. The LCO also requires that all SG tubes that satisfy the plugging criteria be plugged in accordance with the Steam Generator Program.

During an SG inspection, any inspected tube that satisfies the Steam Generator Program plugging criteria is removed from service by plugging. If a tube was determined to satisfy the plugging criteria but was not plugged, the tube may still have tube integrity.

In the context of this specification, a SG tube is defined as the entire length of the tube, including the tube wall between the tube-to-tubesheet weld at the tube inlet and the tube-to-tubesheet weld at the tube outlet. The tube-to-tubesheet weld is not considered part of the tube.

SHEARON HARRIS - UNIT 1 B 3/4 4-2d Amendment No. 145

REACTOR COOLANT SYSTEM BASES 3/4.4.5 STEAM GENERATOR (SG) TUBE INTEGRITY (continued)

A SG tube has tube integrity when it satisfies the SG performance criteria.

The SG performance criteria are defined in Specification 6.8.4.l and describe acceptable SG tube performance. The Steam Generator Program also provides the evaluation process for determining conformance with the SG performance criteria.

There are three SG performance criteria: structural integrity. accident induced leakage. and operational leakage. Failure to meet any one of these criteria is considered failure to meet the LCO.

The structural integrity preformance criterion provides a margin of safety against tube burst or collapse under normal and accident conditions. and ensures structural integrity of the SG tubes under all anticipated transients includued in the design specification. Tube burst is defined as. "The gross structural failure of the tube wall. The condition typically corresponds to an unstable opening displacement (e.g., opening area increased in response to constant pressure) accompanied by ductile (plastic) tearing of the tube material at the ends of the degradation." Tube collapse is defined as. "For the load displacement curve for a given structure. collapse occurs at the top of the load verses displacement curve where the slope of the curve becomes zero." The structural integrity performance criterion provides guidance on assessing loads that have a significant effect on burst or collaspe. In that context. the term "significant" is defined as "An accident loading condition other than differential pressure is considered significant when the addition of such loads in the assessment of the structural integrity performance criterion could cause a lower structural limit or limiting burst/collapse condition to be established." For tube integrity evaluations. except for circumferential degradation. axial thermal loads are classified as secondary loads. For circumferential degradation. the classification of axial thermal loads as primary or secondary loads will be evaluated on a case-by-case basis.

The division between primary and secondary classifications will be based on detailed analysis and/or testing.

Structural integrity requires that the primary membrane stress intensity in a tube not exceed the yield strength for all ASME Code.Section III. Service Level A (normal operating conditions). and Service Level B (upset conditions).

transients included in the design specification. This includes safety factors and applicable design basis loads based on ASME Code,Section III, Subsection NB (Reference 3) and Draft Regulatory Guide 1.121 (Reference 4).

SHEARON HARRIS - UNIT 1 B 3/4 4-2e Amendment No. 124

REACTOR COOLANT SYSTEM BASES 3/4.4.5 STEAM GENERATOR (SG) TUBE INTEGRITY (continued)

The accident induced leakage performance criterion ensures that the primary-to-secondary leakage caused by a design basis accident. other than a SGTR. is within the accident analysis assumptions. The accident analysis assumes that accident induced leakage does not exceed 1 gpm total from all SGs. The accident induced leakage rate includes any primary-to-secondary leakage existing prior to the accident in addition to primary-to-secondary leakage induced during the accident.

The operational leakage performance criterion provides an observable indication of SG tube conditions during plant operation. The limit on operational leakage is contained in LCO 3.4.6.2 and limits primary-to-secondary leakage through any one SG to 150 gpd. This limit is based on the assumption that a single crack leaking this amount would not propagate to a SGTR under the stress conditions of a LOCA or a main steam line break. If this amount of leakage is due to more than one crack. the cracks are very small.

and the above assumption is conservative.

APPLICABILITY SG tube integrity is challenged when the pressure differential across the tubes is large. Large differential pressures across SG tubes can only be experienced in MODES 1.2.3. or 4.

RCS conditions are far less challenging in MODES 5 and 6 than during MODES 1.2.3. and 4. In MODES 5 and 6. primary-to-secondary differential pressure is low. resulting in lower stresses and reduced potential for leakage.

ACTIONS The ACTIONS are modified by a note clarifying that the Conditions may be entered independently for each SG tube. This clarification is acceptable because the required ACTIONS provide appropriate compensatory actions for each affected SG tube. Complying with the required ACTIONS may allow for continued operation. and subsequent affected SG tubes are governed by subsequent Condition entry and application of associated required ACTIONS.

SHEARON HARRIS - UNIT 1 B 3/4 4-2f Amendment No. 124 I

REACTOR COOLANT SYSTEM BASES 3/4.4.5 STEAM GENERATOR (SG) TUBE INTEGRITY (continued)

ACTIONS a.1 and a.2 ACTIONS a.1 and a.2 apply if it is discovered that one or more SG tubes examined in an Inservice Inspection satisfy the tube plugging criteria but were not plugged in accordance with the Steam Generator Program as required by Surveillance Requirement 4.4.5.2. An evaluation of SG tube integrity of the affected tube(s) must be made. SG tube integrity is based on meeting the SG performance criteria described in the Steam Generator Program. The SG plugging criteria define limits on SG tube degradation that allow for flaw growth between inspections while still providing assurance that the SG performance criteria will continue to be met. In order to determine if a SG tube that should have been plugged has tube integrity, an evaluation must be completed that demonstrates that the SG performance criteria will continue to be met until the next refueling outage or SG tube inspection. The tube integrity determination is based on the estimated condition of the tube at the time the situation is discovered and the estimated growth of the degradation prior to the next SG tube inspection. If it is determined that tube integrity is not being maintained, ACTION b. applies.

An allowed completion time of seven days is sufficient to complete the evaluation while minimizing the risk of plant operation with a SG tube that may not have tube integrity.

If the evaluation determines that the affected tube(s) have tube integrity, ACTION a.2 allows plant operation to continue until the next refueling outage or SG inspection provided the inspection interval continues to be supported by an operational assessment that reflects the affected tubes.

However, the affected tube(s) must be plugged prior to entering HOT SHUTDOWN following the next refueling outage or SG inspection. This allowed completion time is acceptable since operation until the next inspection is supported by the operational assessment.

ACTION b.

If the requirements and associated completion time of ACTION a. are not met or if SG tube integrity is not being maintained, the reactor must be brought to HOT STANDBY within 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and COLD SHUTDOWN within the next 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />. The allowed completion times are reasonable, based on operating experience, to reach the desired plant conditions from full power conditions in an orderly manner and without challenging plant systems.

SHEARON HARRIS - UNIT 1 B 3/4 4-2g Amendment No. 145

REACTOR COOLANT SYSTEM BASES 3/4.4.5 STEAM GENERATOR (SG) TUBE INTEGRITY (continued)

Surveillance Requirements 4.4.5.1 During shutdown periods, the SGs are inspected as required by this SR and the Steam Generator Program. NEI 97-06, Steam Generator Program Guidelines (Reference 1), and its referenced EPRI Guidelines, establish the content of the Steam Generator Program. Use of the Steam Generator Program ensures that the inspection is appropriate and consistent with accepted industry practices.

During SG inspections, a condition monitoring assessment of the SG tubes is performed. The condition monitoring assessment determines the "as found" condition of the SG tubes. The purpose of the condition monitoring assessment is to ensure that the SG performance criteria have been met for the previous operating period.

The Steam Generator Program determines the scope of the inspection and the method used to determine whether the tubes contain flaws satisfying the tube plugging criteria. Inspection scope (i.e., which tubes or area of tubing within the SG are to be inspected) is a function of existing and potential degradation locations. The Steam Generator Program also specifies the inspection methods to be used to find potential degradation. Inspection methods are a function of degradation morphology, nondestructive examination (NDE) technique capabilities, and inspection locations.

The Steam Generator Program defines the frequency of SR 4.4.5.1. The frequency is determined by the operational assessment and other limits in the SG examination guidelines (Reference 5).

The Steam Generator Program uses information on existing degradations and growth rates to determine an inspection frequency that provides reasonable assurance that the tubing will meet the SG performance criteria at the next scheduled inspection. In addition, specification 6.8.4.l contains prescriptive requirements concerning inspection intervals to provide added assurance that the SG performance criteria will be met between scheduled inspections. If crack indications are found in any SG tube, the maximum inspection interval for all affected and potentially affected SGs is restricted by specification 6.8.4.I until subsequent inspections support extending the inspection interval.

SHEARON HARRIS - UNIT 1 B 3/4 4-2h Amendment No. 145

REACTOR COOLANT SYSTEM BASES 3/4.4.5 STEAM GENERATOR (SG) TUBE INTEGRITY (continued) 4.4.5.2 During an SG inspection, any inspected tube that satisfies the Steam Generator Program plugging criteria is removed from service by plugging. The tube plugging criteria delineated in specification 6.8.4.l are intended to ensure that tubes accepted for continued service satisfy the SG performance criteria with allowance for error in the flaw size measurement and for future flaw growth. In addition, the tube plugging criteria, in conjunction with other elements of the Steam Generator Program, ensure that the SG performance criteria will continue to be met until the next inspection of the subject tube(s). Reference 1 provides guidance for performing operational assessments to verify that the tubes remaining in service will continue to meet the SG performance criteria.

The frequency of "Prior to entering HOT SHUTDOWN following a SG inspection" ensures that the Surveillance has been completed and all tubes meeting the plugging criteria are plugged prior to subjecting the SG tubes to significant primary-to-secondary pressure differential.

References

1. NEI 97-06, "Steam Generator Program Guidelines"
2. 10 CFR 50.67
3. ASME Boiler and Pressure Vessel Code,Section III, Subsection NB
4. Draft Regulatory Guide 1.121, "Basis for Plugging Degraded Steam Generator Tubes,"

August 1976

5. EPRI, "Pressurized Water Reactor Steam Generator Examination Guidelines" SHEARON HARRIS - UNIT 1 B 3/4 4-2i Amendment No. 145

REACTOR COOLANT SYSTEM BASES 3/4.4.6 REACTOR COOLANT SYSTEM LEAKAGE 3/4.4.6.1 LEAKAGE DETECTION SYSTEMS The RCS Leakage Detection Systems required by this specification are provided to monitor and detect leakage from the reactor coolant pressure boundary.

These Detection Systems are consistent with the recommendations of Regulatory Guide 1.45. "Reactor Coolant Pressure Boundary Leakage Detection Systems."

May 1973.

3/4.4.6.2 OPERATIONAL LEAKAGE

Background

Components that contain or transport the coolant to or from the reactor core make up the reactor coolant system CRCS). Component joints are made by welding. bolting. rolling. or pressure loading. and valves isolate connecting systems from the RCS.

During plant life. the joint and valve interfaces can produce varying amounts of reactor coolant leakage. through either normal operational wear or mechanical deterioration. The purpose of the RCS operational leakage LCO is to limit system operation in the presence of leakage from these sources to amounts that do not compromise safety. This LCO specifies the types and amounts of leakage.

10 CFR 50. Appendix A. GDC 30 (Reference 1). requires means for detecting and.

to the extent practical. identifying the source of reactor coolant leakage.

Regulatory Guide 1.45 (Reference 2) describes acceptable methods for selecting leakage detection systems.

The safety significance of RCS leakage varies widely depending on its source.

rate. and duration. Therefore. detecting and monitoring reactor coolant leakage into the containment area is necessary. Quickly separating the IDENTIFIED LEAKAGE from the UNIDENTIFIED LEAKAGE is necessary to provide quantitative information to the operators. allowing them to take corrective action should a leak occur that is detrimental to the safety of the facility and the public.

A limited amout of leakage inside containment is expected from auxiliary systems that cannot be made 100% leaktight. Leakages from these systems should be detected. located and isolated from containment atmosphere. if possible. to not interfere with RCS leakage detection.

This LCO deals with protection of the reactor coolant system pressure boundary (RCPB) from degradation and the core from inadequate cooling. in addition to preventing the accident analyses radiation release assumptions from being exceeded. The consequences of violating this LCO include the possibility of a loss of coolant accident (LOCA).

SHEARON HARRIS - UNIT 1 B 3/4 4-3 Amendment No. 124

REACTOR COOLANT SYSTEM BASES 3/4.4.6.2 OPERATIONAL LEAKAGE (continued)

Applicable Safety Analyses Except for primary-to-secondary leakage. the safety analyses do not address operational leakage. However. other operational leakage is related to the safety analyses for a LOCA; the amount of leakage can affect the probability of such an event. In some analyses developed by the industry. the steam discharge to the atmosphere is based on the total primary-to-secondary leakage from all SGs of 1 gallon per minute (gpm) or is assumed to increase to 1 gpm as a result of accident induced conditions. The HNP accident analyses assume the amount of primary-to-secondary SG tube leakage is 1 gpm. This 1 gpm leak rate includes the primary-to-secondary leakage rate existing immediately prior to the accident plus any additional increase in primary-to-secondary leakage induced during the accident. The LCO requirement to limit primary-to-secondary leakage through any one SG is limited to less than or equal to 150 gpd. which is significantly less than the conditions assumed in the safety analysis.

Primary-to-secondary leakage is a factor in the dose releases outside containment resulting from a steam line break CSLB) accident or a steam generator tube rupture (SGTR). The leakage contaminates the secondary fluid.

The FSAR analysis for a SGTR assumes the contaminated secondary fluid is released directly to the atmosphere due to a failure of the PORV in the open position and will continue atmospheric release until the time that the PORV can be isolated. The FSAR analysis for the SLB assumes that the SG with the failed steam line boils dry releasing all of the iodine directly to the environment and that iodine carried over to the faulted SG by tube leaks are also released directly to the environment until the RCS has cooled to below 212 degrees F. The dose consequences resulting from the SGTR and the SLB accidents are within the limits defined in 10 CFR 50.67.

The RCS operational leakage satisfies Criterion 2 of 10 CFR 50.36(c)(2)(ii).

SHEARON HARRIS - UNIT 1 B 3/4 4-3a Amendment No. 124

REACTOR COOLANT SYSTEM BASES 3/4.4.6.2 OPERATIONAL LEAKAGE (continued)

Limiting Condition for Operation (LCD)

Reactor Coolant System operational leakage shall be limited to:

a. PRESSURE BOUNDARY LEAKAGE No PRESSURE BOUNDARY LEAKAGE is allowed. being indicative of material deterioration. Leakage of this type is unacceptable as the leak itself could cause further deterioration. resulting in higher leakage.

Violation of this LCD could result in continued degradation of the Reactor Coolant Pressure Boundary. Leakage past seals and gaskets is not PRESSURE BOUNDARY LEAKAGE.

b. UNIDENTIFIED LEAKAGE One gallon per minute (gpm) of UNIDENTIFIED LEAKAGE is allowed as a reasonable minimum detectable amount that the containment air monitoring and containment sump level monitoring equipment can detect within a reasonable time period. Violation of this LCD could result in continued degradation of the Reactor Coolant Pressure Boundary. if the leakage is from the pressure boundary.
c. PRIMARY-TO-SECONDARY LEAKAGE THROUGH ANY ONE STEAM GENERATOR The limit of 150 gpd per SG is based on the operational leakage performance criterion in NEI 97-06. Steam Generator Program Guidelines (Reference 3).

The Steam Generator Program operational leakage performance criterion in NEI 97-06 states. "The RCS operational primary-to-secondary leakage through any one steam generator shall be limited to 150 gallons per day."

The limit is based on operating experience with steam generator tube degradation mechanisms that result in tubeleakage. The operational leakage rate criterion in conjunction with the implementation of the Steam Generator Program is an effective measure for minimizing the frequency of SG tube ruptures.

SHEARON HARRIS - UNIT 1 B 3/4 4-3b Amendment No. 124 I

REACTOR COOLANT SYSTEM BASES 3/4.4.6.2 OPERATIONAL LEAKAGE (continued)

d. IDENTIFIED LEAKAGE Up to 10 gpm of IDENTIFIED LEAKAGE is considered allowable because leakage is from known sources that do not interfere with detection of UNIDENTIFIED LEAKAGE and is well within the capability of the Reactor Coolant System Makeup System. IDENTIFIED LEAKAGE includes leakage to the containment from specifically known and located sources. but does not include PRESSURE BOUNDARY LEAKAGE or CONTROLLED LEAKAGE. Violation of this LCO could result in continued degradation of a component or system.
e. CONTROLLED LEAKAGE The CONTROLLED LEAKAGE limitation restricts operation when the total flow supplied to the reactor coolant pump seals exceeds 31 gpm with the modulating valve in the supply line fully open at a nominal RCS pressure of 2235 psig. This limitation ensures that in the event of a LOCA. the safety injection flow will not be less than assumed in the accident analysis.
f. REACTOR COOLANT SYSTEM PRESSURE ISOLATION VALVE LEAKAGE The maximum allowable leakage from any RCS pressure isolation valve is sufficiently low to ensure early detection of possible in-series check valve failure. It is apparent that when pressure isolation is provided by two in-series check valves and when failure of one valve in the pair can go undetected for a substantial length of time. verification of valve integrity is required. Since these valves are important in preventing overpressurization and rupture of the ECCS low pressure piping, which could result in a LOCA that bypasses containment. these valves should be tested periodically to ensure low probability of gross failure.

SHEARON HARRIS - UNIT 1 B 3/4 4-3c Amendment No. 124

REACTOR COOLANT SYSTEM BASES 3/4.4.6.2 OPERATIONAL LEAKAGE (continued)

Applicability In MODES 1.2.3. and 4. the potential for RCPB leakage is greatest when the RCS is pressurized.

In Modes 5 and 6. leakage limits are not required because the reactor coolant pressure is far lower. resulting in lower stresses and reduced potentials for leakage.

ACTIONS

a. If any PRESSURE BOUNDARY LEAKAGE exists. or primary-to-secondary leakage is not within limit. the reactor must be brought to HOT STANDBY within 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and COLD SHUTDOWN within the next 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />. This action reduces the leakage and also reduces the factors that tend to degrade the pressure boundary.

The allowed completion times are reasonable. based on operating experience. to reach the required plant conditions from full power conditions in an orderly manner and without challenging plant systems.

In COLD SHUTDOWN. the pressure stresses acting on the RCPB are much lower.

and further deterioration is much less likely.

b. UNIDENTIFIED LEAKAGE. IDENTIFIED LEAKAGE. or CONTROLLED LEAKAGE in excess of the LCD limits must be reduced to within the limits within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />.

This completion time allows time to verify leakage rates and either identify UNIDENTIFIED LEAKAGE or reduce leakage to within limits before the reactor must be shut down. Otherwise. the reactor must be brought to HOT STANDBY within 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />. This action is necessary to prevent further deterioration of the RCPB.

c. With RCS Pressure Isolation Valve leakage in excess of the limit. the high pressure portion of the affected system must be isolated within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />. or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />. and COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />. This action is necessary to prevent over pressurization of low pressure systems. and the potential for intersystem LOCA.

SHEARON HARRIS - UNIT 1 B 3/4 4-3d Amendment No. 124

REACTOR COOLANT SYSTEM BASES 3/4.4.6.2 OPERATIONAL LEAKAGE (continued)

Surveillance Requirements 4.4.6.2.1 Verifying RCS leakage to be within the LCO limits ensures that the integrity of the RCPB is maintained. PRESSURE BOUNDARY LEAKAGE would at first appear as UNIDENTIFIED LEAKAGE and can only be positively identified by inspection. It should be noted that leakage past seals and gaskets is not PRESSURE BOUNDARY LEAKAGE. UNIDENTIFIED LEAKAGE and IDENTIFIED LEAKAGE are determined by performance of an RCS water inventory balance.

The RCS water inventory balance must be met with the reactor at steady-state operating conditions (stable pressure, temperature, power level, pressurizer and makeup tank levels, makeup and letdown, and RCP seal injection and return flows). The surveillance is modified by a note. The note states that this SR is not required to be performed until 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> after establishing steady-state operation. The 12-hour allowance provides sufficient time to collect and process all necessary data after stable plant conditions are established.

Steady-state operation is required to perform a proper water inventory balance since calculations during maneuvering are not useful. For RCS operational leakage determination by water inventory balance, steady-state is defined as stable RCS pressure, temperature, power level, pressurizer and makeup tank levels, makeup and letdown, and RCP seal injection and return flows.

An early warning of PRESSURE BOUNDARY LEAKAGE or UNIDENTIFIED LEAKAGE is provided by the automatic systems that monitor containment atmosphere radioactivity and reactor cavity sump level. It should be noted that leakage past seals and gaskets is not PRESSURE BOUNDARY LEAKAGE. These leakage detection systems are specified in LCO 3.4.6.1, "Reactor Coolant System Leakage Detection Systems."

Part (d) notes that this SR is not applicable to primary-to-secondary leakage. This is because leakage of 150 gallons per day cannot be measured accurately by an RCS water inventory balance.

The surveillance frequency is controlled under the Surveillance Frequency Control Program.

SHEARON HARRIS - UNIT 1 B 3/4 4-3e Amendment No. 154

REACTOR COOLANT SYSTEM BASES 3/4.4.6.2 OPERATIONAL LEAKAGE (continued) 4.4.6.2.2 The Surveillance Requirements for RCS Pressure Isolation Valves provide added assurance of valve integrity thereby reducing the probability of gross valve failure and consequent intersystem LOCA. Leakage from the RCS pressure isolation valve is IDENTIFIED LEAKAGE and will be considered as a portion of the allowed limit.

4.4.6.2.3 This SR verifies that primary-to-secondary leakage is less than or equal to 150 gpd through any one SG. Satisfying the primary-to-secondary leakage limit ensures that the operational leakage performance criterion in the Steam Generator Program is met. If this Surveillance Requirement is not met, compliance with LCO 3.4.5 should be evaluated. The 150-gpd limit is measured at room temperature as described in Reference 4. The operational leakage rate limit applies to leakage through any one SG.

If it is not practical to assign the leakage to an individual SG, all the primary-to-secondary leakage should be conservatively assumed to be from one SG.

The surveillance is modified by a note, which states that the Surveillance is not required to be performed until 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> after the establishment of steady-state operation. For RCS primary-to-secondary leakage determination, steady-state is defined as stable RCS pressure, temperature, power level, pressurizer and makeup tank levels, makeup and letdown, and RCP seal injection and return flows.

The surveillance frequency is controlled under the Surveillance Frequency Control Program. The primary-to-secondary leakage is determined using continuous process radiation monitors or radiochemical grab sampling in accordance with the EPRI guidelines (Reference 4).

References

1. 10 CFR 50, Appendix A, GDC 30
2. Regulatory Guide 1.45, May 1973
3. NEI 97-06, "Steam Generator Program Guidelines"
4. EPRI, "Pressurized Water Reactor Primary-to-Secondary Leak Guidelines" SHEARON HARRIS - UNIT 1 B 3/4 4-3f Amendment No. 154

REACTOR COOLANT SYSTEM BASES 3/4.4.7 CHEMISTRY The limitations on Reactor Coolant System chemistry ensure that corrosion of the Reactor Coolant System is minimized and reduces the potential for Reactor Coolant System leakage or failure due to stress corrosion. Maintaining the chemistry within the Steady-State Limits provides adequate corrosion protection to ensure the structural integrity of the Reactor Coolant System over the life of the plant. The associated effects of exceeding the oxygen, chloride, and fluoride limits are time and temperature dependent. Corrosion studies show that operation may be continued with contaminant concentration levels in excess of the Steady-State Limits, up to the Transient Limits, for the specified limited time intervals without having a significant effect on the structural integrity of the Reactor Coolant System. The time interval permitting continued operation within the restrictions of the Transient Limits provides time for taking corrective actions to restore the contaminant concentrations to within the Steady-State Limits.

The Surveillance Requirements provide adequate assurance that concentrations in excess of the limits will be detected in sufficient time to take corrective action. The surveillance frequency is controlled under the Surveillance Frequency Control Program.

SHEARON HARRIS - UNIT 1 B 3/4 4-4 Amendment No. 154

REACTOR COOLANT SYSTEM BASES

=**= * - = = = = = = * *=*--=--


=*=*--===***-=-**=** **-*** ... .. - *--**-*--****-**-- - ---*- *-

314 A 8 SPECIFIC ACHVITY The limitations on the speCJf1c activit of the reactor coolant ensure that the result*tng 2-ho.ur doses at the SITE DARY w'ill not exceed an appropriately smaH fraction of 10 CFR Part 100 dose gufdeline values following a steam generator tube rupture accident in conjunction with an assumed steady-state reactor-to-secondary steam .generator leakage rate of 1 gpm. The values for the limits ific activity represent limits based upon a parametric ev~lw,~ion the , of typical site locations .. These values are conservative rn t spec1f1c s1te parameters of the SHEARON HARRIS site, such as SITE BOUNDARY location and meteorological conditions, were not considered 1n this evaluation.

The ACTION statement permitting POWER OPERATION to continue for limited time periods with the reactor coolant's s iflc activity greater than LO microCurie/gram DOSE EQUIVALENT 131, bu~ less than. 60.0 micr0Curie/9ram l DOSE EQUI\/ALENT I-131. acc:OOlilodates posJnble iodine sp1kmg phenomeoon wh1th may occur following changes rn THERMAL POWER See Generic Letter 85-19 for add1tional infonnat1on.

The sample analysis for determinrng the gross specif1c activity and E can exclude the rad1oiodines because of the low reactor coolant limit of LO microCvrie/gram OOSE EQUIVALHIT I~ 131. and because, if the limit fs exceeded. the rddiofodine level is to be determined every 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />. If the gross specif1c activity level and radioiodine level in the reactor coolant were at their limits, the ra(hoiodine contribution would be a roximately U.

In a release of reactor coolant with at ical mixture of rad ivity. the actual rad101odine contribution would pr bly be about 20%. The exclusion of radionuclides with half~lives less than 15 minutes from these determinations has been made for several reasons. The f1rst consideration is the diff1culty to identify short- hved radionucl ides in a sample that ui res a siqni ficant t1me to collect, transport. and analyze. The second cons deration 1s the predictable delay time between the postulated release of radioactiv1ty from the reactor coolant to its reledse to the environment .and transport to the SITE BOUNDARY, which is relatable to at least 30 minutes decay time. The choice of 15 m1nutes for the half-life cutoff was made because of the nuclear characteristics of the typical reactor coolant radioactivity.

The radionuclides in the typical reactor coolant have half- Jives of less than 4 minutes or half- lives of greater than 14 minutes. which allows a

':iHEARON HARR15 UN 11 1 Amendment No 124

REAC;.! *L. ii , TE7.I BASES SPECIFIC ACTIVITY (Continued) distinction between the radionuclides above and below a half-life of 15 minutes. For these reasons the radionuclides that are excluded from consideration are expected to decay to very low levels before they could be transiorted conditon. from the reactor coolant to the SITE BOUNDARY under' any accident Based upon the above considerations for excluding certain radionuclides from the sample analysis, the allowable time of 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> between sample taking and completing the initial analysis is based upon a typical time necessary to perform the sampling, transport the sample, and perform the analysis of about 90 minutes. After 90 minutes, the gross count should be made in a reproducible geometry of sample and counter having reproducible beta or gamma self-shielding properties. he counter should be reset to a reproducible

.efficiency versus energy. It is not necessary to identify specific nuclides.

The radiochemical determination of nuclides should be based on multiple counting of the sample within typical counting basis following sampling of less than 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />. about 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />, about 1 day, about 1 week. and about month.

Reducing TI to less than 500°F prevents the release of activity should a steam geneartor tube rupture occur, since the saturation pressure of the reactor coolant is below the lift pressure of the atmospheric steam relief valves. The Surveillance Reguirements provide adequate assurance that excessive specific activity levels in the reactor coolant will be detected in sufficient time to take corrective action. A reduction in frequency of isotopic analyses following power changes may be permissible if justified by the data obtained.

3/4.4.9 PRESSURE/TEMPERATURE LIMITS The temperature and pressure changes during heatup and cooldown are limited to be consistent with the requirements given in the ASME Boiler and Pressure Vessel Code.Section XI. Appendix G. ASME Code Case N-640, and 10 CFR 50 Appendix G and H. 10 CFR 50. Appendix G also addresses the metal temperature of the closure head flange and vessel flange regions. The minimum metal temperature of the closure flange region should be at least 120°F higher than the limiting RT NDT for these regions when the pressure exceeds 20% (621 psig for Westinghouse plants) of the preservice hydrostatic test pressure. For Shearon. Harris Unit 1. the minimum temperature of the closure flange and vessel flange regions is 120°F because the limiting RT NDT is O°F (see Table B 3/4 4-1).

1. The reactor coolant temperature and pressure and system cooldown and heatup rates (with the exception of the pressurizer) shall be limited in accordance with Figures 3.4-2 and 3.4-3 and Table 4.4-6 for the service period specified thereon:
a. Allowable combinations of pressure and temperature for specific temperature change rates are below and to the right of the limit lines shown. Limit lines for cooldown rates between those presented may be obtained by interpolation:

and SHEARON HARRIS - UNIT I B 3/4 4-6 Amendment No. 100

REACTOR COOLANT SYSTEM BASES PRESSURE/TEMPERATURE LIMITS (Continued)

b. Figures 3.4-2 and 3.4-3 define limits to assure prevention of non-ductile failure only. For normal operation, other inherent plant characteristics, e.g.,

pump heat addition and pressurizer heater capacity, may limit the heatup and cooldown rates that can be achieved over certain pressure-temperature ranges.

2. These limit lines shall be calculated periodically using methods provided below,
3. The secondary side of the steam generator must not be pressurized above 200 psig if the temperature of the steam generator is below 70°F,
4. The pressurizer heatup and cooldown rates shall not exceed 100°F/h and 200°F/h, respectively. The spray shall not be used if the temperature difference between the pressurizer and the spray fluid is greater than 625°F, and
5. System preservice hydrotests and inservice leak and hydrotests shall be performed at pressures in accordance with the requirements of ASME Boiler and Pressure Vessel Code,Section XI.

The fracture toughness testing of the ferritic materials in the reactor vessel was performed in accordance with the 1971 Winter Addenda to Section III of the ASME Boiler and Pressure Vessel Code. The fracture toughness testing of the ferritic materials associated with the replacement reactor vessel head (RRVH) was performed in accordance with the 2001 Edition, with Addenda up to and including 2003, of Section III of the ASME Boiler and Pressure Vessel Code. These properties are then evaluated in accordance with the NRC Standard Review Plan.

Heatup and cooldown limit curves are calculated using the most limiting value of the nil-ductility reference temperature, RTNDT, at the end of 36 effective full power years (EFPY) of service life.

The reactor vessel materials have been tested to determine their initial RTNDT; the results of these tests are shown in Table B 3/4.4-1. Reactor operation and resultant fast neutron (E greater than 1 MeV) irradiation can cause an increase in the RTNDT. Therefore, an adjusted reference temperature, based upon the fluence, copper content, and nickel content of the material in question, can be predicted using Figure B 3/4.4-1 and the value of RTNDT, including margin, computed by Regulatory Guide 1.99, Revision 2, "Radiation Embrittlement of Reactor Vessel Materials."

Revision 1 SHEARON HARRIS - UNIT 1 B 3/4 4-7 Amendment No. 100

TABLE B 3/4.4-1 REACTOR VESSEL TOUGHNESS CHARPY INITIAL UPPER SHELF ENERGY Cu Ni TNDT RTNDT TRANSVERSE COMPONENT GRADE HEAT NO (wt.%) (wt.%) (°F) (°F) FT LB Closure Hd. A508,Gr3,CL1 16W84 0.04 0.83 -40 -40 210 Vessel Flange A508, CL2 5302-V1 - - -10 -8 110 Inlet Nozzle " 438B-4 - - -20 -20 169

" " " 438B-5 - - 0 0 128

" " " 438B-6 - - -20 -20 149 Outlet Nozzle " 439B-4 - - -10 -10 151

" " " 439B-5 - - -10 -10 152

" " " 439B-6 - - -10 -10 150 Nozzle Shell A533B,CL1 C0224-1 .12 - -20 -1 90

" " " C0123-1 .12 - 0 42 84 Inter. Shell* " A9153-1 .09 .46 -10 60 83

" "* " B4197-2 .09 .50 -10 91 71 Lower Shell* " C9924-1 .08 .47 -10 54 98

" "* " C9924-2 .08 .47 -20 57 88 Bottom Hd. Torus " A9249-2 - - -40 14 94

" " Dome A9213-2 - - -40 -8 125 Weld (Inter & Lower Shell 4P4784 .05 .91 -20 -20 > 94 Vertical Weld Seams)*

Weld (Inter. to Lower Shell 5P6771 .03 .94 -80 -20 80 Girth Seam)*

  • For Beltline Materials, copper and nickel valves are "best estimates".

Revision 1 SHEARON HARRIS - UNIT 1 B 3/4 4-8 Amendment No. 68

N E

(J C

....a, 0

l1J

~ 1.0 A

w Cl) 0 C:

a,

J u::

. * **,* i

! I ; .

I I

  • ! r *; *
___ \_ ;**71, I
,1 r*

tt -1*

' I .  : ' ' I

-i-*rt~t-*-r-+-'.

i ' I '  ; I I I  !

1 I I

. I '

I i

\

i I

i I

I i

I i

I I

I I I I I

' I I

I

- ' --\ +---i---- --; - .- 1--t .. -*:--*t-t-*-t----- t- ;.-

1, 1 1

1: i I

1 1,  : 1 *

--  !*--\

I ' I  : I  !

I i '. I

  • I i

I I ' I I

I

, *  : I  ! I  : 1

' I  ; ' I l t '. I

* ' , I l I
\ I ~
I ~

i ',  : \  : '

i

,

  • I i

I '

8 13 18 23 28 33 38 Operating Time (EFPY)

FIGURE B 3/4.4-1 FAST NEUTRON FLUENCE CE>lMeV) AS A FUNCTION OF FULL POWER SERVICE LIFE.

B 3/4 4-9 Amendment No. 100 SHEARON HARRIS - UNIT 1

FIGURE 8 3/4.4-2 DELETED SHEARON HARRIS - UNIT 1 B 3/4 4-10 Amendment No. 19

REACTOR COOLANT SYSTEM BASES PRESSURE/TEMPERATURE LIMITS (Continued)

The cooldown and heatup limits of Figures 3.4-2 and 3.4-3 are based upon an adjusted RTNor (initial RTNor plus predicted adjustments for this shift in RTNor plus margin).

In accordance with Regulatory Guide 1.99. Revision 2. the results from the material surveillance program. evaluated according to ASTM E185. may be used to determine ~TNor when two or more sets of credible surveillance data are available. Capsules will be removed and evaluated in accordance with the requirements of ASTM E185-82 and 10 CFR Part 50. Appendix H. The results obtained from the surveillance specimens can be used to predict future radiation damage to the reactor vessel material by using the lead factor and the withdrawal time of the capsule. The cooldown and heatup curves must be recalculated when the ~TNor determined from the surveillance capsule exceeds the calculated ~TNor for the equivalent capsule radiation exposure.

Allowable pressure-temperature relationships for various cooldown and heatup rates are calculated using methods derived from Appendix G in Section XI of the ASME Boiler and Pressure Vessel Code as required by Appendix G to 10 CFR Part 50 and ASME Code Case N-640 for the reactor vessel controlling material.

The general method for calculating heatup and cooldown limit curves is based upon the principles of the linear elastic fracture mechanics (LEFM) technology. In the calculation procedures for the beltline shell region a semielliptical surface defect with a depth of one-quarter of the wall thickness. T. and a length of 3/2T is assumed to exist at the inside of the vessel wall as well as at the outside of the vessel wall. A semielliptical inside corner flaw is assumed for the nozzle regions with a depth of one-quarter of the nozzle belt wall thickness. The inlet nozzle is used in the calculation procdures since the inner radius of this tapered nozzle is larger at the corner than the inner radius of the more tapered outlet nozzle. The dimensions of these postulated cracks. referred to in Appendix G of ASME Section XI as reference flaws. amply exceed the current capabilities of inservice inspection techniques. Therefore. the reactor operation limit curves developed for reference crack are conservative and provide sufficient safety margins for protection against nonductile failure. To assure that the radiation embrittlement effects are accounted for in the calculation of the limit curves. the most limiting value of the nil-ductility reference tempera-ture. RTNoT* is used and this includes the radiation-induced shift. 6RTNoT*

corresponding to the end of the period for which cooldown and heatup curves are generated.

The ASME approach for calculating the allowable limit curves for various heatup and cooldown rates specifies that the total stress intensity factor. K1

  • for the combined tnermal and pressure stresses at any time during heatup or cooldown cannot be greater than the reference stress intensity factor. K1R. for the SHEARON HARRIS - UNIT 1 8 3/4 4-11 Amendment No. 100

REACTOR COOLANT SYSTEM BASES PRESSURE/TEMPERATURE LIMITS (Continued) metal temperature at that time. KIR is obtained from reference fracture toughness curves defined in the ASME Code. Pressure-temperature limits are developed for the vessel using the KIR curve defined in Appendix A to the ASME Code, as permitted by ASME Code Case N-640. For the Replacement Reactor Vessel Head (RRVH), pressure-temperature limits are developed, using KIR = KIc curve from ASME Section XI, Appendix G, 2007 Edition through 2008 Addenda. For the remaining components of the primary pressure boundary, pressure-temperature limits are based on the KIR curve defined in Appendix G to the ASME Code. The KIR curves are given by the equations:

Vessel regions:

KIR = KIc = 33.2 + 2.806 exp [0.02(T-RTNDT + 100°F)] (1a)

Remaining regions:

KIR = KIa = 26.8 + 1.233 exp [0.0145(T-RTNDT + 160°F)] (1b)

Where: KIR is the reference stress intensity factor as a function of the metal temperature T and the metal nil-ductility reference temperature RTNDT. Thus, the governing equation for the heatup-cooldown analysis is defined in Appendix G of the ASME Code as follows:

C KIM + KIt KIR (2)

Where: KIM = the stress intensity factor caused by membrane (pressure) stress, KIt = the stress intensity factor caused by the thermal gradients, KIR = constant provided by the Code as a function of temperature relative to the RTNDT of the material, C = 2.0 for level A and B service limits, and C = 1.5 for inservice leak and hydrostatic (ISLH) test operations.

At any time during the heatup or cooldown transient, KIR is determined by the metal temperature at the tip of the postulated flaw, the appropriate value for RTNDT, and the reference fracture toughness curve. The thermal stresses resulting from temperature gradients through the wall are calculated and then the corresponding thermal stress intensity factor, KIT, for the reference flaw is computed. The pressure stress intensity factors are obtained and allowable pressures are calculated from equation 2.

COOLDOWN For the calculation of the allowable pressure versus coolant temperature during cooldown, the Code reference flaw is assumed to exist at the inside of the vessel wall and the inlet nozzle corner. During cooldown, the controlling location of the flaw is always at the inside surface because the thermal gradients produce tensile stresses at the inside, which increase with increasing cooldown rates. Allowable pressure-temperature relations are generated for both steady-state and finite cooldown rate situations. From these relations, composite limit curves are constructed for each cooldown rate of interest. The composite limit curves are developed considering the controlling reactor vessel component, either the beltline shell, RV head flange limit, or the inlet nozzle.

Revision 1 SHEARON HARRIS - UNIT 1 B 3/4 4-12 Amendment No. 100

REACTOR COOLANT SYSTEM BASES PRESSURE/TEMPERATURE LIMITS (Contlnued)

The use of the composite curve in the cooldown analysis is necessary because control of the cooldown procedure is based on measurement of reactor coolant temperature. whereas the l1miting pressure 1s actually dependent on the material temperature at the tip of the assumed flaw During cooldown. the l/4T inside surface location is at a h1gher temperature than the fluid adjacent to the inside surface. This condition. of course. is not true for the steady-state situat1on. It follows that. at any given reactor coolant temperature. the ~T developed during cooldown results in a higher value of KIA at the l/4T location for finite cooldown rates than for steady-state operation. Furthermore. if condit10ns exist such that the increase in K,R exceeds K~. the calculated allowable pressure during cooldown will be greater than the steady-state value.

The above procedures are needed because there is no direct control on temperature at the l/4T location: therefore. allowable pressures may unknowingly be violated if the rate of cooling is decreased at various intervals along a cooldown ramp. The use of the composite curve eliminates th1s problem and assures conservative operation of the system for the entire cooldown period.

HEATUP Three separate calculations are required to determine the limit curves for finite heatup rates. As is done in the cooldown analysis. allowable pressure-temperature relationships are developed for steady-state conditions as well as finite heatup rate conditions assuming the presence of a l/4T defect at the inside surface. The thermal gradients during heatup produce compressive stresses at the 1nside surface that alleviate the tensile stresses produced by internal pressure. The metal temperature at the crack tip lags the coolant temperature: therefore. the K,A for the l/4T crack during heatup is lower than the K,A for the l/4T crack during steady-state conditions at the same coolant temperature. During heatup. esQecially at the end of the tran-sient. conditions may ex1st such that the effects of compressive thermal stresses and different K,A*s for steady-state and finite heatup rates do not offset each other and the pressure-temperature curve based on steady-state conditions no longer represents a lower bound of all similar curves for finite heatup rates when the l/4T flaw is considered. Therefore. both cases have to be analyzed in order to assure that at any coolant temperature the lower value of the allowable pressure calculated for steady-state and finite heatup rates is obtained.

The second portion of the heatup analysis concerns the calculation of pressure-temperature limitations for the case in which a l/4T deep outside surface flaw is assumed. Unlike the situation at the vessel inside surface. the thermal gradients established at the outside surface during heatup produce stresses which are tensile in nature and thus tend to reinforce any pressure stresses present. These thermal stresses. of course. are dependent on both the rate of SHEARON HARRIS - UNIT 1 B 3/4 4-13 Amendment No. 100

R[ACTQR COQLANT SYSTEM BASES PR[SSUR£/TEMPEBATURE LIMITS (Continued) heatup and the time Cor coolant temperature) along the heatup ra~.

Furthermore. since the thermal stresses at the outside are tensile and increase ~th increasing heatup rate. a lower bound curve cannot be defined.

Rather. each heatup rat~ of interest must be analyzed on an individual basis.

Foll~ng the generation of pressure-temperature curves for both the steadY-state and finite heatup rate situations. the final limit curves are produced as follows. A c~site curve is constructed based on a point-by-point comparison of the steadY-state and finite heatup rate data. At any given temperature. the allowable pressure is taken to be the lesser of the three values taken from the curves under consideration.

The use of the composite curve is necessary to set conservative heatup limita-tions because it is possible for conditions to exist such that over the course of the heatup ramp the controlling condition s~tches from the inside to the outside and the pressure limit must at all times be based on analysis of the most critical criterion.

The compQsite curves for the heatup rate data and the cooldown rate data in Figures 3.4-2 and 3.4-3 have not been adjusted for possible errors in the pressure and temperature sensin9 instruments. However. the heatuQ and cooldown curves in plant operat1ng procedures have been adjusted for these instrument errors. The instrument errors are controlled by the Technical Specification Equipment List Program. Plant Procedure PLP-106.

  • xsLH. pressure-temperature CP-T) curves may be used for inservice leak and hydrostatic tests with fuel in the reactor vessel. However. ISLH tests required by the ASHE code must be completed before the core is critical.

Although the pressurizer operates in t~rature ranges above those for which there 1s reason for concern of nonductile failure. operating limits are provided to assure compatibility of o~ration with the fatigue analysis performed in accordance with the ASHE Code requirements.

LQW TEMPERATURE OVERPRESSURE PROTECTION The OPERABILITY of two PORVs or an RCS vent o~ning of at least 2.9 square inches ensures that the RCS will be protected from pressure transients which could exceed the limits of Appendix G to 10 CFR Part 50 when one or more of the RCS cold l~s are less than or equal to 325°F. Either PORV has adequate relieving capab1lity to protect the RCS from overpressurization when the transient is limiteij to either: (1) the start of an idle RCP with the secondary water temperature of the steam generator less than 50°F abOve the RCS cold leg temperatures. or (2) the start of a charging/safety injection pump and its injection into a water-solid RCS.

The maximum allowed PORV setpoint for the Low Temperature Overpressure Protection System (LTOPS) is derived by analysis which moaels the performance SHEARON HARRIS - UNIT 1 B 3/4 4-14 Amendment No. 68

REACTOR COOLANT SYSTEM BASES LOW TEMPERATURE OVERPRESSURE PROTECTION (Continued) of the LTOPS assuming various mass input and heat input transients.

Operation with a PORV setpoint less than or equal to the maximum setpoint ensures that Appendix G criteria will not be violated with consideration for a maximum pressure overshoot beyond the PORV setpoint which can occur as a result of time delays in signal processing and valve opening, instrument uncertainties, and single failure. LTOP instrument uncertainties are controlled by the Technical Specification Equipment List Program, Plant Procedure PLP-106. To ensure that mass and heat input transients more severe than those assumed cannot occur, Technical Specifications require lockout of all but one charging/safety injection pump while in MODES 4 (below 325°F), 5 and 6 with the reactor vessel head installed and disallow start of an RCP if secondary temperature is more than 50°F above primary temperature.

The maximum allowed PORV setpoint for the LTOPS will be updated based on the results of examinations of reactor vessel material irradiation surveillance specimens performed as required by 10 CFR Part 50, Appendix H, and the reactor vessel service life.

3/4.4.10 STRUCTURAL INTEGRITY The inservice inspection and testing programs for ASME Code Class I, 2, and 3 components ensure that the structural integrity and operational readiness of these components will be maintained*at an acceptable level throughout the life of the plant. These programs are in accordance with Section XI of the ASME Boiler and Pressure Vessel Code and applicable -Addenda as required by 10 CFR 50.55a(g) except where specific written relief has been granted by the Commission pursuant to 10 CFR 50.55a(g)(6)(i).

Components of the Reactor Coolant System were designed to provide access to permit inservice inspections in accordance with Section XI of the ASME Boiler and Pressure Vessel Code, 1977 Edition and Addenda through Summer 1978.

3/4.4.11 REACTOR COOLANT SYSTEM VENTS Reactor Coolant System vents are provided to exhaust noncondensible gases and/or steam from the Reactor Coolant System that could inhibit natural circulation core cooling. The OPERABILITY of least one Reactor Coolant System vent path from the reactor vessel head and the pressurizer steam space ensures that the capability exists to perform this function.

The valve redundancy of the Reactor Coolant System vent paths serves to minimize the probability of inadvertent or irreversible actuation while ensuring that a single failure of a vent valve, power supply, or control system does not prevent isolation of the vent path.

  • The function, capabilities, and testing requirements of the Reactor Coolant System vents are consistent with the requirements of Item II.B.1 of NUREG-0737,"Clarification of TMI Action Plant Requirements," November 1980.

SHEARON HARRIS - UNIT 1 B 3/4 4-15 Amendment No. 38 1

3/4.5 EMERGENCY CORE COOLING SYSTEMS BASES 3/4.5.1 ACCUMULATORS The OPERABILITY of each Reactor Coolant System (RCS) accumulator ensures that a sufficient volume of borated water will be immediately forced into the reactor core through each of the cold legs in the event the RCS pressure falls below the pressure of the accumulators. This initial surge of water into the core provides the initial cooling mechanism during large RCS pipe ruptures.

The limits on accumulator volume, boron concentration and pressure ensure that the assumptions used for accumulator injection in the safety analysis are met. The value of 66%

indicated level ensures that a minimum of 7440 gallons is maintained in the accumulators. The maximum indicated level of 96% ensures that an adequate volume exists for nitrogen pressurization.

The accumulator power operated isolation valves are considered to be "operating bypasses" in the context of IEEE Std. 279-1971, which requires that bypasses of a protective function be removed automatically whenever permissive conditions are not met. In addition, as these accumulator isolation valves fail to meet single failure criteria, removal of power to the valves is required.

The limits for operation with an accumulator inoperable for any reason except an isolation valve closed or boron concentration not within limits minimizes the time exposure of the plant to a LOCA event occurring concurrent with failure of an additional accumulator which may result in unacceptable peak cladding temperatures. The boron in the accumulators contributes to the assumption that the combined ECCS water in the partially recovered core during the early reflooding phase of a large break LOCA is sufficient to keep that portion of the core subcritical.

One accumulator below the minimum boron concentration limit, however, will have no effect on the available ECCS water and an insignificant effect on core subcriticality during reflood. Boiling of ECCS water in the core during reflood concentrates boron in the saturated liquid that remains in the core. In addition, current analysis demonstrates that the accumulators do not discharge following a large steam line break for HNP. Therefore, 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> is permitted to return the boron concentration to within limits. If a closed isolation valve cannot be immediately opened, the full capability of one accumulator is not available and prompt action is required to place the reactor in a mode where this capability is not required.

3/4.5.2 AND 3/4.5.3 ECCS SUBSYSTEMS The OPERABILITY of two independent ECCS subsystems ensures that sufficient emergency core cooling capability will be available in the event of a LOCA assuming the loss of one subsystem through any single failure consideration. Either subsystem operating in conjunction with the accumulators is capable of supplying sufficient core cooling to limit the peak cladding temperatures within acceptable limits for all postulated break sizes ranging from the double ended break of the largest RCS cold leg pipe downward. In addition, each ECCS subsystem provides long-term core cooling capability in the recirculation mode during the accident recovery period.

Management of gas voids is important to ECCS OPERABILITY. ECCS piping and components have the potential to develop voids and pockets of entrained gases. Preventing and managing gas intrusion and accumulation is necessary for proper operation of the ECCS and may also prevent water hammer, pump cavitation, and pumping of noncondensible gas into the reactor vessel.

A Surveillance Requirement verifies that required ECCS locations susceptible to gas accumulation are sufficiently filled with water. Selection of ECCS locations susceptible to gas accumulation is based on a review of system design information, including piping and SHEARON HARRIS - UNIT 1 B 3/4 5-1 Amendment No. 150

3/4.5 EMERGENCY CORE COOLING SYSTEMS BASES ECCS SUBSYSTEMS (Continued) instrumentation drawings, isometric drawings, plan and elevation drawings, and calculations. The design review is supplemented by system walk downs to validate the system high points and to confirm the location and orientation of important components that can become sources of gas or could otherwise cause gas to be trapped or difficult to remove during system maintenance or restoration. Susceptible locations depend on plant and system configuration, such as stand-by versus operating conditions.

The ECCS is OPERABLE when it is sufficiently filled with water. Acceptance criteria are established for the volume of accumulated gas at susceptible locations. If accumulated gas is discovered that exceeds the acceptance criteria for the susceptible location (or the volume of accumulated gas at one or more susceptible locations exceeds an acceptance criteria for gas volume at the suction or discharge of a pump), the Surveillance is not met. If it is determined by subsequent evaluation that the ECCS is not rendered inoperable by the accumulated gas (i.e., the system is sufficiently filled with water), the Surveillance may be declared met. Accumulated gas should be eliminated or brought within the acceptance criteria limits. If any accumulated gas is eliminated or brought within the acceptance criteria limits as part of the Surveillance performance, the Surveillance is considered met and the system is OPERABLE. Past operability is then evaluated under the Corrective Action program. If it is suspected that a gas intrusion event is occurring, then this is evaluated under the Operability Determination Process.

ECCS locations susceptible to gas accumulation are monitored and, if gas is found, the gas volume is compared to the acceptance criteria for the location. Susceptible locations in the same system flow path which are subject to the same gas intrusion mechanisms may be verified by monitoring a representative sub-set of susceptible locations. Monitoring may not be practical for locations that are inaccessible due to radiological or environmental conditions, the plant configuration, or personnel safety. For these locations alternative methods (e.g., operating parameters, remote monitoring) may be used to monitor the susceptible location. Monitoring is not required for susceptible locations where the maximum potential accumulated gas void volume has been evaluated and determined to not challenge system OPERABILITY. The accuracy of the method used for monitoring the susceptible locations and trending of the results should be sufficient to assure system OPERABILITY during the Surveillance interval.

With the RCS temperature below 350°F, one OPERABLE ECCS subsystem is acceptable without single failure consideration on the basis of the stable reactivity condition of the reactor and the limited core cooling requirements.

The limitation for a maximum of one charging/safety injection pump to be OPERABLE and the Surveillance Requirement to verify one charging/safety injection pump OPERABLE below 325°F provides assurance that a mass addition pressure transient can be relieved by the operation of a single PORV.

SHEARON HARRIS - UNIT 1 B 3/4 5-1a Amendment No. 150

EMERGENCY CORE COOLING SYSTEMS BASES ECCS SUBSYSTEMS (Continued)

The Surveillance Requirements provided to ensure OPERABILITY of each component ensures that at a minimum, the assumptions used in the safety analyses are met and that subsystem OPERABILITY is maintained. Surveillance Requirements for throttle valve position and flow balance testing provide assurance that proper ECCS flows will be maintained in the event of a LOCA. Maintenance of proper flow resistance and pressure drop in the piping system to each injection point is necessary to: (1) prevent total pump flow from exceeding runout conditions when the system is in its minimum resistance configuration, (2) provide the proper flow split between injection points in accordance with the assumptions used in the ECCS-LOCA analyses, and (3) provide an acceptable level of total ECCS flow to all injection points equal to or above that assumed in the ECCS-LOCA analyses.

The Surveillance Requirement provided to verify the correct position of valves in the flow path is modified by a note which exempts system vent flow paths opened under administrative control.

The administrative control should be proceduralized and include stationing a dedicated individual at the system vent flow path who is in continuous communication with the operators in the control room. This individual will have a method to rapidly close the system vent flow path if directed.

3/4.5.4 REFUELING WATER STORAGE TANK The OPERABILITY of the refueling water storage tank (RWST) as part of the ECCS ensures that a sufficient supply of borated water is available for injection into the core by the ECCS. This borated water is used as cooling water for the core in the event of a LOCA and provides sufficient negative reactivity to adequately counteract any positive increase in reactivity caused by RCS cooldown. RCS cooldown can be caused by inadvertent depressurization, a LOCA, or a steam line rupture.

The limits on RWST minimum volume and boron concentration assure that: (1) sufficient water is available within containment to permit recirculation cooling flow to the core and (2) the reactor will remain subcritical in the cold condition following mixing of the RWST and the RCS water volumes with all shutdown and control rods inserted except for the most reactive control assembly. These limits are consistent with the assumption of the LOCA and steam line break analyses.

The contained water volume limit includes an allowance for water not usable because of tank discharge line location or other physical characteristics.

The limits on contained water volume and boron concentration of the RWST also ensure a pH value of between 7.0 and 11.0 for the solution recirculated within containment after a LOCA.

This pH band minimizes the evolution of iodine and minimizes the effect of chloride and caustic stress corrosion on mechanical systems and components.

An RWST allowed outage time of 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> is permitted during performance of Technical Specification surveillance 4.4.6.2.2 with a dedicated attendant stationed at valve 1CT-22 in communication with the Control Room. The dedicated attendant is to remain within the RWST compartment whenever valve 1CT-22 is open during the surveillance. The dedicated attendant can manually close valve 1CT-22 within 30 minutes in case of a line break caused by a seismic event. Due to the piping configuration, a break in the non-seismic portion of piping during this surveillance could result in draining the RWST below the minimum analyzed volume.

SHEARON HARRIS - UNIT 1 B 3/4 5-2 Amendment No. 150

3/4.6 CONTAINMENT SYSTEMS BASES 3/4.6.1 PRIMARY CONTAINMENT 3/4.6.1.1 CONTAINMENT INTEGRITY Primary CONTAINMENT INTEGRITY ensures that the release of radioactive materials from the containment atmosphere will be restricted to those leakage paths and associated leak rates assumed in the safety analyses. This restriction. in conjunction with the leakage rate limitation. will limit the SITE BOUNDARY radiation doses to within the dose guideline values of 10 CFR Part 100 during accident conditions.

3/4.6.1.2 CONTAINMENT LEAKAGE The limitations on containment leakage rates ensure that the total containment leakage volume will not exceed the value assumed in the safety analyses at the peak acci.dent pressure. Pa. As an added conservatism. the measured overall integrated leakage rate is further limited to less than or equal to 0.75 La.

during performance of the periodic test. to account for possible degradation of the containment leakage barriers between leakage tests.

The surveillance testing for measuring leakage rates is consistent with the requirements of Appendix J of 10 CFR Part 50. Option A for Type Band C tests.

and the Containment Leakage Rate Testing Program for Type A tests.

3/4.6.1.3 CONTAINMENT AIR LOCKS fhe limitations on closure and leak rate for the containment air locks are required to meet the restrictions on CONTAINMENT INTEGRITY and containment leak rate. Surveillance testing of the air lock seals provides assurance that the overall air lock leakage will not become excessive due to seal damage during the intervals between air lock leakage tests.

Action statement "a" has been modified by a note. The note allows use of the air lock for entry and exit for seven days under administrative controls if both air locks have an inoperable door. This seven day restriction begins when a door in the second air lock is discovered to be inoperable.

Containment entry may be required to perform Technical Specification surveillances and actions. as well as other activities on equipment inside containment that are required by Technical Specifications CTS) or other activities that support TS required equipment. In addition. containment entry may be required to perform repairs on vital plant equipment. which if not repaired. could lead to a plant transient or a reactor trip. This note is not intended to preclude performing other activities Ci .e .. non-TS required activities or repairs on non-vital plant equipment) if the containment is entered. using the inoperable air lock. to perform an allowed activity listed above. This allowance is acceptable due to the low probability of an event that could pressurize containment during the short time that an OPERABLE door is expected to be open.

SHEARON HARRIS - UNIT 1 B 3/4 6-1 Amendment No. 91

3/4.6 CONTAINMENT SYSTEMS BASES CONTAINMENT AIR LOCKS (Continued)

Maintaining containment air locks OPERABLE requires compliance with the leakage rate test requirements of 10 CFR 50. Appendix J. as modified by approved exemptions. HNP has an approved exemption to Appendix J Option A.

paragraph III.D.2 of 10 CFR 50 in that the Overall air lock leakage test is requ1red to be performed if maintenance has been performed that could affect the air lock sealing capability prior to establishing CONTAINMENT INTEGRITY.

This is in contrast to the Appendix J requirement if air locks are opened during periods when containment integrity is not required by the plant's Techn1cal Specifications shall be tested at the end of such periods.

3/4.6.1.4 INTERNAL PRESSURE The limitations on containment internal pressure ensure that: (1) the containment structure is prevented from exceeding its design negative pressure differential with respect to the outside atmosphere of -2 psig. and (2) the containment peak pressure does not exceed the design pressure of 45 psig.

The maximum peak pressure expected to be obtained from a postulated LOCA is 41.8 psig using a value of 1.6 psig for initial positive containment Rressure.

The -1" wg was chosen to be consistent with the initial assumptions of the accident analyses.

SHEARON HARRIS - UNIT 1 B 3/4 6-1a Amendment No. 107 I '

I

CONTAINMENT SYSTEMS BASES 3/4.6.1.5 AIR TEMPERATURE The limitations on containment average air temperature ensure that the overall containment average air temperature does not exceed the initial temperature condition assumed in the safety analysis for a LOCA or steam line break accident. Measurements shall be made at all listed locations. whether by fixed or portable instruments. prior to determining the average air temperature.

3/4.6.1.6 CONTAINMENT STRUCTURAL INTEGRITY This limitation ensures that the structural integrity of the containment will be maintained comparable to the original design standards for the life of the facility. Structural integrity is required to ensure that the containment will withstand the maximum pressure of a postulated LOCA (41.8 psig). A visual inspection in conjunction with the Containment Leakage Rate Testing Program is sufficient to demonstrate this capability.

3/4.6.1.7 CONTAINMENT VENTILATION SYSTEM The 42-inch containment preentry purge makeup and exhaust isolation valves are required to be sealed closed during plant operations in MODES 1. 2. 3 and 4 since these valves have not been demonstrated capable of closing during a LOCA or steam line break accident. Maintaining these valves sealed closed during these MODES ensures that excessive quantities of radioactive materials will not be released via the Pre-entry Containment Purge System. To provide assurance that these containment valves cannot be inadvertently opened. the valves are sealed closed in accordance with Standard Review Plan 6.2.4 which includes mechanical devices to seal or lock the valve closed. or prevents power from being supplied to the valve operator.

The use of the Normal Containment Purge System is restricted to the 8-inch purge makeup and exhaust isolation valves since. unlike the 42-inch valves.

the 8-inch valves are capable of closing during a LOCA or steam line break accident. Therefore. the SITE BOUNDARY dose guideline of 10 CFR Part 100 would not be exceeded in the event of an accident during normal containment PURGING operation. The total time the Normal Containment Purge System isolation valves may be open during MODES 1. 2. 3. and 4 in a calendar year is a function of anticipated need and operating experience. Only safety-related reasons: e.g .. containment pressure control or the reduction of airborne radioactivity to facilitate personnel access for surveillance and maintenance activities. may be used to justify the opening of these isolation valves during MODES 1. 2. 3. and 4.

Leakage integrity tests with a maximum allowable leakage rate for containment purge makeup and exhaust supply valves will provide early indication of resil-ient material seal degradation and will allow opportunity for repair before SHEARON HARRIS - UNIT 1 B 3/4 6-2 Amendment No. 107 I '

I

CONTAINMENT SYSTEMS BASES CONTAINMENT VENTILATION SYSTEM (Continued) gross leakage failures could develop. The 0.60 La leakage limit of Specification 3.6.1.2b. shall not be exceeded when the leakage rates determined by the leakage integrity tests of these valves are added to the previously determined total for all valves and penetrations subject to Type B and C tests.

3/4.6.2 DEPRESSURIZATION AND COOLING SYSTEMS 3/4.6.2.1 CONTAINMENT SPRAY SYSTEM The OPERABILITY of the Containment Spray System ensures that containment depressurization and cooling capability will be available in the event of a LOCA or steam line break. The pressure reduction and resultant lower containment leakage rate are consistent with the assumptions used in the safety analyses.

The Containment Spray System and the Containment Fan Coolers are redundant to each other in providing post-accident cooling of the containment atmosphere. However, the Containment Spray System also provides a mechanism for removing iodine from the containment atmosphere and therefore the time requirements for restoring an inoperable spray system to OPERABLE status have been maintained consistent with that assigned other inoperable ESF equipment.

Management of gas voids is important to Containment Spray System OPERABILITY.

Containment Spray System piping and components have the potential to develop voids and pockets of entrained gases. Preventing and managing gas intrusion and accumulation is necessary for proper operation of the containment spray trains and may also prevent water hammer and pump cavitation.

A Surveillance Requirement verifies that required Containment Spray System locations susceptible to gas accumulation are sufficiently filled with water. Selection of Containment Spray System locations susceptible to gas accumulation is based on a review of system design information, including piping and instrumentation drawings, isometric drawings, plan and elevation drawings, and calculations. The design review is supplemented by system walk downs to validate the system high points and to confirm the location and orientation of important components that can become sources of gas or could otherwise cause gas to be trapped or difficult to remove during system maintenance or restoration. Susceptible locations depend on plant and system configuration, such as stand-by versus operating conditions.

The Containment Spray System is OPERABLE when it is sufficiently filled with water. Acceptance criteria are established for the volume of accumulated gas at susceptible locations. If accumulated gas is discovered that exceeds the acceptance criteria for the susceptible location (or the volume of accumulated gas at one or more susceptible locations exceeds an acceptance criteria for gas volume at the suction or discharge of a pump), the Surveillance is not met. If it is determined by subsequent evaluation that the Containment Spray System is not rendered inoperable by the accumulated gas (i.e., the system is sufficiently filled with water), the Surveillance may be declared met. Accumulated gas should be eliminated or brought within the acceptance criteria limits. If any accumulated gas is eliminated or brought within the acceptance criteria limits as part of the Surveillance performance, the Surveillance is considered met and the system is OPERABLE. Past operability is then evaluated under the Corrective Action program. If it is suspected that a gas intrusion event is occurring, then this is evaluated under the Operability Determination Process.

Containment Spray System locations susceptible to gas accumulation are monitored and, if gas is found, the gas volume is compared to the acceptance criteria for the location. Susceptible locations in the same system flow path which are subject to the same gas intrusion mechanisms SHEARON HARRIS - UNIT 1 B 3/4 6-3 Amendment No. 150

CONTAINMENT SYSTEMS BASES CONTAINMENT SPRAY SYSTEM (Continued) may be verified by monitoring a representative sub-set of susceptible locations. Monitoring may not be practical for locations that are inaccessible due to radiological or environmental conditions, the plant configuration, or personnel safety. For these locations alternative methods (e.g.,

operating parameters, remote monitoring) may be used to monitor the susceptible location.

Monitoring is not required for susceptible locations where the maximum potential accumulated gas void volume has been evaluated and determined to not challenge system OPERABILITY.

The accuracy of the method used for monitoring the susceptible locations and trending of the results should be sufficient to assure system OPERABILITY during the Surveillance interval.

The Surveillance Requirement provided to verify the correct position of valves in the flow path is modified by a note which exempts system vent flow paths opened under administrative control.

The administrative control should be proceduralized and include stationing a dedicated individual at the system vent flow path who is in continuous communication with the operators in the control room. The individual will have a method to rapidly close the system vent flow path if directed.

3/4.6.2.2 SPRAY ADDITIVE SYSTEM The OPERABILITY of the Spray Additive System ensures that sufficient NaOH is added to the containment spray in the event of a LOCA. The limits on NaOH volume and concentration ensure a pH value of between 7.0 and 11.0 for the solution recirculated within containment after a LOCA. This pH band minimizes the evolution of iodine and minimizes the effect of chloride and caustic stress corrosion on mechanical systems and components. The contained solution volume limit includes an allowance for solution not usable because of tank discharge line location or other physical characteristics. These assumptions are consistent with the iodine removal efficiency assumed in the safety analyses.

The maximum and minimum volumes for the Spray Additive Tank are based on the analytical limits. The specified indicated levels used for surveillance include instrument uncertainties and unusable tank volume.

3/4.6.2.3 CONTAINMENT COOLING SYSTEM The OPERABILITY of the Containment Fan Coolers ensures that adequate heat removal capacity is available when operated in conjunction with the Containment Spray Systems during post-LOCA conditions.

ESW flowrate to the Containment Fan Coolers will vary based on reservoir level. Acceptable ESW flowrate is dependent on the number of heat exchanger tubes in service. Surveillance test acceptance criteria should be adjusted for these factors.

SHEARON HARRIS - UNIT 1 B 3/4 6-3a Amendment No. 150

CONTAINMENT SYSTEMS BASES The Containment Fan Coolers and the Containment Spray System are redundant to each other in providing post-accident cooling of the containment atmosphere.

As a result of this redundancy in cooling capability, the allowable out-of-service time requirements for the Containment Fan Coolers have been appropriately adjusted. However. the allowable out-of-service time requirements for the Containment Spray System have been maintained consistent with that assigned other inoperable ESF equipment since the Containment Spray System also provides a mechanism for removing iodine from the containment atmosphere.

3/4.6.3 CONTAINMENT ISOLATION VALVES The OPERABILITY of the containment isolation valves ensures that the containment atmosphere will be isolated from the outside environment in the event of a release of radioactive material to the containment atmosphere or pressurization of the containment and is consistent with the requirements of General Design Criteria 54 through 57 of Appendix A to 10 CFR Part 50.

Containment isolation within the time limits specified for those isolation valves designed to close automatically ensures that the release of radioactive material to the environment will be consistent with the assumptions used in the analyses for a LOCA.

Reopening of an inoperable containment isolation valve is allowed to permit I

surveillance testing to demonstrate its operability of the operability of other equipment per Specification 4.6.3.1. or to change to compliance with another action statement for the LCD. An example of choosing an alternate action statement would be installing a blind flange versus using the failed closed containment isolation valve to isolate the penetration. This action would facilitate repair of the failed isolation valve. then removing the blind flange and re-installing the repaired valve. This process is acceptable because it results in restoring the penetration to its design configuration sooner that waiting for a plant shutdown to complete the repairs.

3/4.6.4 COMBUSTIBLE GAS CONTROL Deleted.

3/4.6.5 VACUUM RELIEF SYSTEM The OPERABILITY of the primary containment to atmosphere vacuum relief valves ensures that the containment internal pressure does not become more negative than -1.93 psig. This condition is necessary to prevent exceeding the con-tainment design limit for internal vacuum of -2 psig.

SHEARON HARRIS - UNIT 1 B 3/4 6-4 Amendment No. 131

3/4.7 PLANf SYSTEMS BASES 3/4.7.1 TURBINE CYCLE 3/4.7.1.1 SAFETY VALVES The OPERABILITY of the main steam line Code safety valves ensures that the Secondary System Qressure will be limited to within 110% (1305 psig) of its design pressure of 1185 psig dur1ng the most severe ant1cipated system opera-tional transient. The maximum rel1eving capacity is associated with a Turb1ne trip from 100% RATED THERMAL POWER coincident with an assumed loss of condenser heat sink (i.e .. no steam bypass to the condenser).

The specified valve lift settings and relieving capacities are in accordance with the requirements of Section III of the ASME Boiler and Pressure Code.

1971 Edition. The 7 total relieving capacity for all valves on all of the steam l1nes is 1.36 x 10 lbs/h which is in excess of 105% of the maximum calculated steam flow of 12.9 x 10 6 lbs/h at 100% RATED THERMAL POWER. A minimum of two OPERABLE safety valves per steam generator ensures that sufficient relieving capac1ty is available for the allowable THERMAL POWER restriction in Table 3. 7-1.

STARTUP and/or POWER OPERATION is allowable with safety valves inoperable within the limitations of the ACTION requ1rements on the basis of the reduction in Secondary Coolant System steam flow and THERMAL POWER required by the reduced Reactor trip settings of the Power Range Neutron Flux channels.

The Reactor Trip Setpoint reductions are derived on the following bases:

For 3 loop operation H10 = ( 100/Q) (ws h,9 N)

K Where:

Hi~= Safety Analysis power range high neutron flux setpoint. percent Q Nominal NSSS power rating of the plant (including reactor coolant pump heat). Mwt K Conversion factor. 947.82 (Btu/sec)

MWt Minimum total steam flow rate capability of the operable MSSVs on any one steam generator at the highest MSSV opening pressure including tolerance and accumulation. as appropriate. in lb/sec.

Heat of vaporization for steam at the highest MSSV opening pressure including tolerance and accumulation. as appropriate.

Btu/lbm N Number of loops in plant The values from th1s algorithm must then be adjusted lower to account for 1nstrument and channel uncertainties. This adjustment will be 9% power.

SHEARON HARRIS - UNlT 1 B 3/4 7 Amendment No. 107 I '

I

3/4.7 PLANT SYSTEMS BASES 3/4.7.1.2 AUXILIARY FEEDWATER SYSTEM The OPERABILITY of the Auxiliary Feedwater System ensures that the Reactor Coolant System can be cooled down to less than 350°F from normal operating conditions so that the Residual Heat Removal System may be placed into operation. The AFW System provides decay heat removal immediately following a station blackout event, and is required to mitigate the Loss of Normal Feedwater and Feedwater Line break accidents analyzed in FSAR Chapter 15. The minimum pump performance requirements are based upon a maximum allowable degradation of the pump performance curves. Pump operation at this level has been demonstrated by calculation to deliver sufficient AFW flow to satisfy the accident analysis acceptance criteria.

With regard to the AFW valve position verification of Surveillance Requirement 4.7.1.2.1 Sub-paragraph b.1, this requirement does not include in its scope the AFW flow control valves inline from the AFW motor-driven pump discharge header to each steam generator when they are equipped with an auto-open feature. The auto-open logic feature is designed to automatically open these valves upon receipt of an Engineered Safety Features System AFW start signal. As a consequence, valves with an auto-open feature do not have a "correct position" which must be verified. The valves may be in any position, in any MODE of operation thereby allowing full use of the AFW System for activities such as to adjust steam generator water levels prior to and during plant start-up, as an alternate feedwater system during hot standby, for cooldown operations, and to establish and maintain wet layup conditions in the steam generators.

SHEARON HARRIS - UNIT 1 B 3/4 7-1a Amendment No. 154

3/4.7 PLANT SYSTEMS BASES 3/4.7.1.3 CONDENSATE STORAGE TANK The OPERABILITY of the condensate storage tank with the minimum water volume ensures that sufficient water is available to maintain the RCS at HOT STANDBY conditions for 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> with steam discharge to the atmosphere concurrent with total loss-of-offsite power. The contained water volume limit includes an allowance for water not usable because of tank discharge line location or other physical characteristics, and the value has also been adjusted in a manner similar to that for the RWST and BAT, as discussed on page B 3/4 1-3.

3/4.7.1.4 SPECIFIC ACTIVITY The limitations on Secondary Coolant System specific activity ensure that the resultant offsite radiation dose will be limited to a small fraction of 10 CFR Part 100 dose guideline values in the event of a steam line rupture. This dose also includes the effects of a coincident 1 gpm reactor-to-secondary tube leak in the steam generator of the affected steam line. These values are consistent with the assumptions used in the safety analyses.

3/4.7.1.5 MAIN STEAM LINE ISOLATION VALVES The OPERABILITY of the main steam line isolation valves ensures that no more than one steam generator will blow down in the event of a steam line rupture. This restriction is required to: (1) minimize the positive reactivity effects of the Reactor Coolant System cooldown associated with the blowdown, and (2) limit the pressure rise within containment in the event the steam line rupture occurs within containment. The OPERABILITY of the main steam isolation valves within the closure times of the Surveillance Requirements are consistent with the assumptions used in the safety analyses.

3/4.7.2 STEAM GENERATOR PRESSURE / TEMPERATURE LIMITATION The limitation on steam generator pressure and temperature ensures that the pressure-induced stresses in the steam generators do not exceed the maximum allowable fracture toughness stress limits. The limitations of 70°F and 200 psig are based on a steam generator RTNDT of 60°F (a generic maximum) and are sufficient to prevent brittle fracture. The Shearon Harris specific RTNDT is limited to a maximum value of 10°F.

SHEARON HARRIS - UNIT 1 B 3/4 7-2 Amendment No. 107

3/4.7 PLANT SYSTEMS BASES 3/4.7.3 COMPONENT COOLING WATER SYSTEM The OPERABILITY of the Component Cooling Water System ensures that sufficient cooling capacity is available for continued operation of safety-related equipment during normal and accident conditions. The redundant cooling capacity of this system, assuming a single failure, is consistent with the assumptions used in the safety analyses.

3/4.7.4 EMERGENCY SERVICE WATER SYSTEM The OPERABILITY of the Emergency Service Water System ensures that sufficient cooling capacity is available for continued operation of safety-related equipment during normal and accident conditions. The redundant cooling capacity of this system, assuming a single failure, is consistent with the assumptions used in the safety analyses.

[Amendment No. 176 deleted pages B 3/4 7-3a through B 3/4 7-3d]

SHEARON HARRIS - UNIT 1 B 3/4 7-3 Amendment No. 176

3/4.7 PLANT SYSTEMS BASES 3/4.7.5 ULTIMATE HEAT SINK The limitations on the ultimate heat sink level and temperature ensure that sufficient cooling capacity is available either: (1) provide normal cooldown of the facility or (2) mitigate the effects of accident conditions within acceptable limits.

The limitations on minimum water level and maximum temperature are based on providing a 30-day cooling water supply to safety-related equipment without exceeding its design basis temperature and is consistent with the recommendations of Regulatory Guide 1.27, "Ultimate Heat Sink for Nuclear Plants," Rev. 2, January 1976.

3/4.7.6 CONTROL ROOM EMERGENCY FILTRATION SYSTEM BACKGROUND The CREFS provides a protected environment from which occupants can control the unit following an uncontrolled release of radioactivity, hazardous chemicals, or smoke.

The CREFS consists of two independent, redundant trains that recirculate and filter the air in the control room envelope (CRE) and a CRE boundary that limits the inleakage of unfiltered air. Each CREFS train consists of a prefilter or demister, a high efficiency particulate air (HEPA) filter, an activated charcoal adsorber section for removal of gaseous activity (principally iodines), and a fan. Ductwork, valves or dampers, doors, barriers, and instrumentation also form part of the system, as well as demisters to remove water droplets from the air stream. A second bank of HEPA filters follows the adsorber section to collect carbon fines and provides backup in case of failure of the main HEPA filter bank. The heaters are not required for OPERABILITY since the carbon laboratory tests are performed at 95% relative humidity, but are maintained in the system to provide additional efficiency margin.

The CRE is the area within the confines of the CRE boundary that contains the spaces that control room occupants inhabit to control the unit during normal and accident conditions. This area encompasses the control room, and may encompass other non-critical areas to which frequent personnel access or continuous occupancy is not necessary in the event of an accident. The CRE is protected during normal operation, natural events, and accident conditions. The CRE boundary is the combination of walls, floor, roof, ducting, doors, penetrations and equipment that physically form the CRE. The OPERABILITY of the CRE boundary must be maintained to ensure that the inleakage of unfiltered air into the CRE will not exceed the inleakage assumed in the licensing basis analysis of design basis accident (DBA) consequences to CRE occupants. The CRE and its boundary are defined in the Control Room Envelope Habitability Program.

The CREFS is an emergency system, parts of which may also operate during normal unit operation in the standby mode of operation. Upon receipt of the actuating signal(s), normal air supply to the CRE is isolated, and the stream of ventilation air is recirculated through the system filter trains. The prefilters or demisters remove any large particles in the air, and any entrained water droplets present, to prevent excessive loading of the HEPA filters and charcoal adsorbers.

The demister is important to the effectiveness of the charcoal adsorbers.

Actuation of the CREFS places the system in the emergency mode (i.e., isolation with recirculation mode) of operation. Actuation of the system closes the unfiltered outside air intake and unfiltered exhaust dampers, and aligns the system for recirculation of the air within the CRE through the redundant trains of HEPA and charcoal filters. The emergency mode also allows for pressurization and filtered ventilation of the air supply to the CRE.

SHEARON HARRIS - UNIT 1 B 3/4 7-3e Amendment No. 170

3/4.7 PLANT SYSTEMS BASES 3/4.7.6 CONTROL ROOM EMERGENCY FILTRATION SYSTEM (Continued)

Outside air is diluted with air from the CRE, filtered, and added to the air being recirculated from the CRE. Pressurization of the CRE minimizes infiltration of unfiltered air through the CRE boundary from all the surrounding areas adjacent to the CRE boundary. The air entering the CRE is continuously monitored by radiation detectors. One detector output above the setpoint will cause actuation of the emergency mode.

A single CREFS train operating with a maximum pressurization flow rate of 400 cfm will pressurize the CRE to at least 0.125 inches water gauge relative to external areas adjacent to the CRE boundary. The CREFS operation in maintaining the CRE habitable is discussed in the FSAR, Section 9.4 (Ref. 1).

Redundant supply and recirculation trains provide the required filtration should an excessive pressure drop develop across the other filter train. Normally open isolation dampers are arranged in series pairs so that the failure of one damper to shut will not result in a breach of isolation. The CREFS is designed in accordance with Seismic Category I requirements.

The CREFS is designed to maintain a habitable environment in the CRE for 30 days of continuous occupancy after a Design Basis Accident (DBA) without exceeding a 5 rem TEDE or its equivalent to any part of the body.

SHEARON HARRIS - UNIT 1 B 3/4 7-3f Amendment No. 153

3/4.7 PLANT SYSTEMS BASES 3/4.7.6 CONTROL ROOM EMERGENCY FILTRATION SYSTEM (Continued)

APPLICABLE SAFETY ANALYSIS The CREFS components are arranged in redundant, safety related ventilation trains. The location of components and ducting within the CRE ensures an adequate supply of filtered air to all areas requiring access. The CREFS provides airborne radiological protection for the CRE occupants, as demonstrated by the CRE occupant dose analyses for the most limiting design basis accident fission product release presented in the FSAR, Chapter 15 (Ref. 2).

The CREFS provides protection from smoke and hazardous chemicals to the CRE occupants.

The analysis of toxic chemical hazards found no impact on control room habitability from toxic chemical sources (Ref. 3). The evaluation of a smoke challenge demonstrates that it will not result in the inability of the CRE occupants to control the reactor either from the control room or from the remote shutdown panels (Ref. 4).

The worst case single active failure of a component of the CREFS, assuming a loss of offsite power, does not impair the ability of the system to perform its design function.

The CREFS satisfies Criterion 3 of 10 CFR 50.36(c)(2)(ii).

LIMITING CONDITION FOR OPERATION (LCO)

Two independent and redundant CREFS trains are required to be OPERABLE to ensure that at least one is available if a single active failure disables the other train. Total system failure, such as from a loss of both ventilation trains or from an inoperable CRE boundary, could result in exceeding a dose of 5 rem TEDE or its equivalent to any part of the body to the CRE occupants in the event of a large radioactive release.

Each CREFS train is considered OPERABLE when the individual components necessary to limit CRE occupant exposure are OPERABLE. A CREFS train is OPERABLE when the associated:

a. Fan is OPERABLE,
b. HEPA filters and charcoal adsorbers are not excessively restricting flow, and are capable of performing their filtration functions, and
c. Demister, ductwork, valves, and dampers are OPERABLE, and air circulation can be maintained.

In order for the CREFS trains to be considered OPERABLE, the CRE boundary must be maintained such that the CRE occupant dose from a large radioactive release does not exceed the calculated dose in the licensing basis consequence analyses for DBAs, and that CRE occupants are protected from hazardous chemicals and smoke.

SHEARON HARRIS - UNIT 1 B 3/4 7-3g Amendment No. 170

3/4.7 PLANT SYSTEMS BASES 3/4.7.6 CONTROL ROOM EMERGENCY FILTRATION SYSTEM (Continued)

LIMITING CONDITION FOR OPERATION (LCO)

A failure to secure the RAB Normal Ventilation System, as part of a control room isolation, results in an inoperable control room boundary. Various postulated alignments or malfunctions of the RAB Normal Ventilation System can result in either excessively positive or negative RAB pressures, which can compromise the ability of the CREFS trains to maintain the control room envelope at a positive pressure of 1/8 INWG or greater relative to adjacent areas, thus directly impacting design basis in-leakage assumptions and personnel dose consequences under accident conditions.

The LCO is modified by a Note allowing the CRE boundary to be opened intermittently under administrative controls. This Note only applies to openings in the CRE boundary that can be rapidly restored to the design condition, such as doors, hatches, floor plugs, and access panels.

For entry and exit through doors, the administrative control of the opening is performed by the person(s) entering or exiting the area. For other openings, these controls should be proceduralized and consist of stationing a dedicated individual at the opening who is in continuous communication with the operators in the CRE. This individual will have a method to rapidly close the opening and to restore the CRE boundary to a condition equivalent to the design condition when a need for CRE isolation is indicated.

SHEARON HARRIS - UNIT 1 B 3/4 7-3h Amendment No. 153

3/4.7 PLANT SYSTEMS BASES 3/4.7.6 CONTROL ROOM EMERGENCY FILTRATION SYSTEM (Continued)

APPLICABILITY In MODES 1, 2, 3, 4, 5, and 6, during movement of irradiated fuel assemblies, and during movement of loads over spent fuel pools, the CREFS must be OPERABLE to ensure that the CRE will remain habitable during and following a DBA.

During movement of irradiated fuel assemblies and movement of loads over spent fuel pools, the CREFS must be OPERABLE to cope with the release from a fuel handling accident involving irradiated fuel.

ACTIONS 3.7.6.a.1 In MODE 1, 2, 3, or 4, when one CREFS train is inoperable, for reasons other than an inoperable CRE boundary, action must be taken to restore OPERABLE status within 7 days. In this condition, the remaining OPERABLE CREFS train is adequate to perform the CRE occupant protection function. However, the overall reliability is reduced because a failure in the OPERABLE CREFS train could result in loss of CREFS function. The 7 day allowed outage time is based on the low probability of a DBA occurring during this time period, and ability of the remaining train to provide the required capability.

In MODE 1, 2, 3, or 4, if the inoperable CREFS train cannot be restored to OPERABLE status within the allowed outage times, the unit must be placed in a MODE that minimizes accident risk.

To achieve this status, the unit must be placed in at least MODE 3 within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />, and in MODE 5 within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />. The allowed outage times are reasonable, based on operating experience, to reach the required unit conditions from full power conditions in an orderly manner and without challenging unit systems.

3.7.6.a.2 In MODE 1, 2, 3, or 4, if the unfiltered inleakage of potentially contaminated air past the CRE boundary and into the CRE can result in CRE occupant radiological dose greater than the calculated dose of the licensing basis analyses of DBA consequences (allowed to be up to 5 rem TEDE or its equivalent to any part of the body), or inadequate protection of CRE occupants from hazardous chemicals or smoke, the CRE boundary is inoperable. Actions must be taken to restore an OPERABLE CRE boundary within 90 days.

During the period that the CRE boundary is considered inoperable, action must be initiated to implement mitigating actions to lessen the effect on CRE occupants from the potential hazards of a radiological or chemical event or a challenge from smoke. Actions must be taken within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> to verify that in the event of a DBA, the mitigating actions will ensure that CRE occupant radiological exposures will not exceed the calculated dose of the licensing basis analyses of DBA consequences, and that CRE occupants are protected from hazardous chemicals and smoke.

These mitigating actions (i.e., actions that are taken to offset the consequences of the inoperable CRE boundary) should be preplanned for implementation upon entry into the condition, regardless of whether entry is intentional or unintentional.

SHEARON HARRIS - UNIT 1 B 3/4 7-3i Amendment No. 153

3/4.7 PLANT SYSTEMS BASES 3.7.6.a.2 (continued)

The 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> allowed outage time is reasonable based on the low probability of a DBA occurring during this time period, and the use of mitigating actions. The 90 day allowed outage time is reasonable based on the determination that the mitigating actions will ensure protection of CRE occupants within analyzed limits while limiting the probability that CRE occupants will have to implement protective measures that may adversely affect their ability to control the reactor and maintain it in a safe shutdown condition in the event of a DBA. In addition, the 90 day allowed outage time is a reasonable time to diagnose, plan and possibly repair, and test most problems with the CRE boundary.

In MODE 1, 2, 3, or 4, if the inoperable CRE boundary cannot be restored to OPERABLE status within the allowed outage times, the unit must be placed in a MODE that minimizes accident risk.

To achieve this status, the unit must be placed in at least MODE 3 within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />, and in MODE 5 within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />. The allowed outage times are reasonable, based on operating experience, to reach the required unit conditions from full power conditions in an orderly manner and without challenging unit systems.

3.7.6 b.1 and c.1 In MODE 5 or 6, or during movement of irradiated fuel assemblies, or during movement of loads over spent fuel pools, when one CREFS train is inoperable, for reasons other than an inoperable CRE boundary, action must be taken to restore OPERABLE status within 7 days. If the inoperable CREFS train cannot be restored to OPERABLE status within the allowed outage time, action must be taken to immediately place the OPERABLE CREFS train in the emergency mode.

This action ensures that the remaining train is OPERABLE, that no failures preventing automatic actuation will occur, and that any active failure would be readily detected.

3.7.6 b.2 and c.2 When both CREFS trains are inoperable, for reasons other than an inoperable CRE boundary, or when the OPERABLE CREFS train required to be in the emergency mode by ACTION b.1 or c.1 is not capable of being powered by an OPERABLE emergency power source, immediately suspend activities that could result in a release of radioactivity that might require isolation of the CRE. This places the unit in a condition that minimizes the accident risk. This does not preclude the movement of fuel to a safe position.

SHEARON HARRIS - UNIT 1 B 3/4 7-3j Amendment No. 153

3/4.7 PLANT SYSTEMS BASES 3.7.6 b.3 and c.3 In MODE 5 or 6, or during movement of irradiated fuel assemblies, or during movement of loads over spent fuel pools, with one or more CREFS trains inoperable due to an inoperable CRE boundary, action must be taken immediately to suspend activities that could result in a release of radioactivity that might require isolation of the CRE. This places the unit in a condition that minimizes the accident risk. This does not preclude the movement of fuel to a safe position.

SURVEILLANCE REQUIREMENTS SR 4.7.6.a Standby systems should be checked periodically to ensure that they function properly. As the environment and normal operating conditions on this system are not too severe, testing each train once every month provides an adequate check of this system. Operation for 15 continuous minutes demonstrates OPERABILITY of the system. Periodic operation ensures that blockage, fan or motor failure, or excessive vibration can be detected for corrective action. The surveillance frequency is controlled under the Surveillance Frequency Control Program.

SR 4.7.6.b, c, e, and f ANSI N510-1980 will be used as a procedural guide for surveillance testing. Criteria for laboratory testing of charcoal and for in-place testing of HEPA filters and charcoal adsorbers is based upon a removal efficiency of 99% for elemental, particulate and organic forms of radioiodine.

SR 4.7.6.d.1 This SR verifies that the HEPA filters and charcoal adsorbers are not excessively blocked. The filter pressure drop was chosen to be half-way between the estimated clean and dirty pressure drops for those components. This assures the full functionality of the filters for a prolonged period, even at the Technical Specification limit. The surveillance frequency is controlled under the Surveillance Frequency Control Program.

SR 4.7.6.d.2 This SR verifies that each CREFS train starts and operated on an actual or simulated actuation signal. The surveillance frequency is controlled under the Surveillance Frequency Control Program.

SHEARON HARRIS - UNIT 1 B 3/4 7-3k Amendment No. 170

3/4.7 PLANT SYSTEMS BASES 3/4.7.6 CONTROL ROOM EMERGENCY FILTRATION SYSTEM (Continued)

SR 4.7.6.g This SR verifies the OPERABILITY of the CRE boundary by testing for unfiltered air inleakage past the CRE boundary and into the CRE. The details of the testing are specified in the Control Room Envelope Habitability Program.

The CRE is considered habitable when the radiological dose to CRE occupants calculated in the licensing basis analyses of DBA consequences is no more than 5 rem TEDE or its equivalent to any part of the body and the CRE occupants are protected from hazardous chemicals and smoke.

This SR verifies that the unfiltered air inleakage into the CRE is no greater than the flow rate assumed in the licensing basis analyses of DBA consequences.

In MODES 1, 2, 3, or 4, when unfiltered air inleakage is greater than the assumed flow rate, ACTION a.2 must be entered. ACTION a.2 allows time to restore the CRE boundary to OPERABLE status provided mitigating actions can ensure that the CRE remains within the licensing basis habitability limits for the occupants following an accident. Compensatory measures are discussed in Regulatory Guide 1.196, Section C.2.7.3, (Ref. 5) which endorses, with exceptions, NEI 99-03, Section 8.4 and Appendix F (Ref. 6). These compensatory measures may also be used as mitigating actions as required by ACTION a.2. Temporary analytical methods may also be used as compensatory measures to restore OPERABILITY (Ref.

7). Options for restoring the CRE boundary to OPERABLE status include changing the licensing basis DBA consequence analysis, repairing the CRE boundary, or a combination of these actions.

Depending upon the nature of the problem and the corrective action, a full scope inleakage test may not be necessary to establish that the CRE boundary has been restored to OPERABLE status.

REFERENCES

1. FSAR, Section 9.4
2. FSAR, Chapter 15
3. FSAR, Section 6.4
4. FSAR, Section 9.5 and Corrective Action Program Assignment 100903-05
5. Regulatory Guide 1.196
6. NEI 99-03,"Control Room Habitability Assessment," June 2001
7. Letter from Eric J. Leeds (NRC) to James W. Davis (NEI) dated January 30, 2004, "NEI Draft White Paper, Use of Generic Letter 91-18 Process and Alternative Source Terms in the Context of Control Room Habitability." (ADAMS Accession No. ML040300694)

SHEARON HARRIS - UNIT 1 B 3/4 7-3l Amendment No. 170

3/4.7 PLANT SYSTEMS BASES 3/4.7.7 REACTOR AUXILIARY BUILDING EMERGENCY EXHAUST SYSTEM The OPERABILITY of the Reactor Auxiliary Building Emergency Exhaust System ensures that radioactive materials leaking from the ECCS equipment within the pump room following a LOCA are filtered prior to reaching the environment. Operation for 15 continuous minutes demonstrates OPERABILITY of the system. Periodic operation ensures that blockage, fan or motor failure, or excessive vibration can be detected for corrective action. The heaters are not required for OPERABILITY since the carbon laboratory tests are performed at 95% relative humidity, but are maintained in the system to provide additional efficiency margin. The operation of this system and the resultant effect on offsite dosage calculations was assumed in the safety analyses. ANSI N510-1980 will be used as a procedural guide for surveillance testing. Criteria for laboratory testing of charcoal and for in- place testing of HEPA filters and charcoal adsorbers is based upon removal efficiencies of 95% for organic and elemental forms of radioiodine and 99% for particulate forms. The filter pressure drop was chosen to be half-way between the estimated clean and dirty pressure drops for these components. This assures the full functionality of the filters for a prolonged period, even at the Technical Specification limit.

The LCO is modified by a note allowing the Reactor Auxiliary Building Emergency Exhaust System (RABEES) ventilation boundary to be opened intermittently under administrative controls.

For entry and exit through doors, the administrative control of opening is performed by the person(s) entering or exiting the area. For other openings, these controls consist of stationing a dedicated individual at the opening who is in continuous communication with the control room.

This individual will have a method to rapidly close the opening when a need for RABEES isolation is indicated.

If the RABEES boundary is inoperable in MODES 1, 2, 3, and 4, the RABEES trains cannot perform their intended functions. Actions must be taken to restore an OPERABLE RABEES boundary within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />. During the period that the RABEES boundary is inoperable, appropriate compensatory measures (consistent with the intent of GDC 19, 60, 64, and 10 CFR Part 100) should be utilized to protect plant personnel from potential hazards such as radioactive contamination, toxic chemicals, smoke, temperature and relative humidity, and physical security.

Preplanned measures should be available to address these concerns. HNP will have written procedures available describing compensatory measures to be taken in the event of an intentional or unintentional entry into this condition. The 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> allowed out of service time is a typically reasonable time to diagnose, plan and possibly repair, and test most problems with the RABEES boundary. The 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> allowed out of service time is reasonable based on the low probability of a DBA occurring during this time period, and the availability of compensatory measures.

SHEARON HARRIS - UNIT 1 B 3/4 7-3m Amendment No. 170

3/4.7 PLANT SYSTEMS BASES 3/4.7.8 SNUBBERS All snubbers are required OPERABLE to ensure that the structural integrity of the Reactor Coolant System and all other safety-related systems is maintained during and following a seismic or other event initiating dynamic loads.

Surveillance to demonstrate OPERABILITY is by performance of an augmented inservice inspection program specified in the Technical Specification Equipment List Program, plant procedure PLP-106. The program is in accordance with the ASME OM Code as required by 10 CFR 50.55a.

Revision 1 SHEARON HARRIS - UNIT 1 B 3/4 7-4 Amendment No. 102

3/4.7 PLANT SYSTEMS BASES 3/4.7.9 SEALED SOURCE CONTAMINATION The sources requiring leak tests are specified in 10 CFR 31.5(c)(2)(ii). The limitation on removable contamination is required by 10 CFR 31.5(c)5. This limitation will ensure that leakage from Byproduct, Source, and Special Nuclear Material sources will not exceed allowable intake values.

Sealed sources are classified into three groups according to their use, with Surveillance Requirements commensurate with the probability of damage to a source in that group. Those sources that are frequently handled are required to be tested more often than those that are not.

Sealed sources that are continuously enclosed within a shielded mechanism (i.e., sealed sources within radiation monitoring or boron measuring devices) are considered to be stored and need not be tested unless they are removed from the shielded mechanism.

3/4.7.10 DELETED 3/4.7.11 DELETED 3/4.7.12 DELETED 3/4.7.13 ESSENTIAL SERVICES CHILLED WATER SYSTEM The OPERABILITY of the Essential Service Chilled Water System ensures that sufficient cooling capacity is available for continued operation of safety related equipment during normal and accident conditions. The redundant cooling capacity of this system, assuming a single failure, is consistent with the assumptions used in the safety analyses.

The TS 3.7.13 action statement completion time of 7 days is for maintenance on the Essential Services Chilled Water System (ESCWS). Entry into this action statement also affects TS 3.1.2.4, Charging Pumps - Operating, TS 3.5.2, ECCS [Emergency Core Cooling Systems]

Subsystems - Tavg Greater Than or Equal To 350°F, TS 3.6.2.1, Containment Spray System, TS 3.6.2.3, Containment Cooling System, and TS 3.7.4, "Emergency Service Water System,"

for B Train ESCWS inoperability only, based upon the impact to the B Emergency Service Water (ESW) Booster Pump operability. The B Train ESW booster pump area is cooled by AH- 8 1X-SB, which is powered by the B Train power supply. There is no impact to the A Train ESW Booster Pump or the A Train ESW System since an air handler unit for this area may be powered by either A or B Train power supplies.

A note similar to the following is placed in each of the above listed TS:

  • One Train of [Applicable TS or TS System] is allowed to be inoperable for a total of 7 days to allow for maintenance on the Essential Services Chilled Water System and air handlers supported by the Essential Services Chilled Water System. Prior to exceeding 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />, the compensatory measures described in TS Bases 3.7.13 and HNP LAR correspondence letter RA-19-0007 shall be implemented.

SHEARON HARRIS - UNIT 1 B 3/4 7-5 Amendment No. 176

3/4.7 PLANT SYSTEMS BASES 3/4.7.13 ESSENTIAL SERVICES CHILLED WATER SYSTEM (Continued)

  1. COMPENSATORY MEASURES FOR 7-DAY ALLOWED OUTAGE TIME 1 The following equipment and the corresponding power supplies will be posted protected:
  • Air handling units for the operable charging safety injection pump (CSIP) areas:

AH-9A (CSIP 1A-SA Area), AH-9B (CSIP 1B-SB Area), or AH-10 (CSIP 1C-SAB Area)

  • Air handling units for the Switchgear Rooms with operable equipment:

AH-12 1A-SA and AH-12 1B-SA supply Switchgear Room A; AH-13 1A-SB and AH-13 1B-SB supply Switchgear Room B

Transient combustibles and hot work in these fire risk-sensitive areas will be limited:

  • Fire compartments FC34 and FC35: Switchgear Room A and Switchgear Room B
  • Fire compartment FC41: Turbine Building (Zone 1-G-261 - 6.9 kV Switchgear)
  • Fire compartment FC54: Transformer Yard 3 Restrictions on work activities will be in place that involve components that if lost or failed could result in a direct plant trip or transient.

4 Operator actions for CSIP area cooling, Switchgear Room cooling, and Auxiliary Relay Cabinet Room cooling, if needed following a loss of HVAC, will be briefed with Operations. The fan used for the CSIP area cooling will be pre-staged and verified to be functional.

5 Discretionary maintenance or discretionary testing on equipment that support the following systems will be avoided for the remaining duration of the TS 3.7.13 LCO entry:

  • Essential Services Chilled Water System (operable train)
  • Alternate Seal Injection System and the Dedicated Shutdown Diesel Generator SHEARON HARRIS - UNIT 1 B 3/4 7-6 Amendment No. 176

3/4.7 PLANT SYSTEMS BASES 3/4.7.14 FUEL STORAGE POOL BORON CONCENTRATION The fuel storage pools contain several rack designs. The PWR and BWR racks in Pools "C" and "D" have a poison that maintains keff less than or equal to 0.95 during normal operation. The BWR racks in Pools "A" and "B" either credit a poison in the rack design or that contained in the rack inserts. For the PWR racks in Pools "A" and "B" and the BWR racks that utilize rack inserts, the racks installed poison is not credited and soluble boron is relied upon to maintain the storage Keff less than or equal to 0.95 during normal operation. Soluble boron is also relied upon during design basis accidents (e.g., fuel handling accident (FHA) or misloading) to maintain keff less than or equal to 0.95. The most limiting boron requirement is 1000 ppm of any of the pools. The difference between 2000 ppm and 1000 ppm provides margin for boron measurement uncertainties and the detection and mitigation of an accidental boron dilution event. It is not required to postulate the boron dilution accidents concurrent with another accident such as fuel misloading or FHA.

The water in the pools normally contains a concentration in excess of 2000 ppm. The pools are typically interconnected through canals. Years of operating data show that the boron concentration does not vary significantly from pool to pool. The sampling surveillance permits taking a sample from any location in the connected volume of the pools. This is typically done by rotating between four widely separated locations (e.g. Pool A, Pool B, Pool C and 1&4 Transfer Canal) in the entire pool volume. Sampling of an individual pool is only required when a specific pool is isolated such that diffusion of the boron between pools is restricted.

SHEARON HARRIS - UNIT 1 B 3/4 7-7 Amendment No. 176

3/4.8 ELECTRICAL POWER SYSTEMS BASES 3/4.8.1, 3/4.8.2, AND 3/4.8.3 A.C. SOURCES, D.C. SOURCES, AND ONSITE POWER DISTRIBUTION The OPERABILITY of the A.C. and D.C power sources and associated distribution systems during operation ensures that sufficient power will be available to supply the safety-related equipment required for: (1) the safe shutdown of the facility, and (2) the mitigation and control of accident conditions within the facility. The minimum specified independent and redundant A.C.

and D.C. power sources and distribution systems satisfy the requirements of General Design Criterion 17 of Appendix A to 10 CFR Part 50.

The switchyard is designed using a breaker-and-a-half scheme. The switchyard currently has seven connections with the Duke Energy transmission network; each of these transmission lines is physically independent. The switchyard has one connection with each of the two Startup Auxiliary Transformers and each SAT can be fed directly from an associated offsite transmission line. The Startup Auxiliary Transformers are the preferred power source for the Class 1E ESF buses. The minimum alignment of offsite power sources will be maintained such that at least two physically independent offsite circuits are available. The two physically independent circuits may consist of any two of the incoming transmission lines to the SATs (either through the switchyard or directly) and into the Class 1E system. As long as there are at least two transmission lines in service and two circuits through the SATs to the Class 1E buses, the LCO is met.

The ACTION requirements specified for the levels of degradation of the power sources provide restriction upon continued facility operation commensurate with the level of degradation. The OPERABILITY of the power sources are consistent with the initial condition assumptions of the safety analyses and are based upon maintaining at least one redundant set of onsite A.C. and D.C. power sources and associated distribution systems OPERABLE during accident conditions coincident with an assumed loss-of-offsite power and single failure of the other onsite A.C.

source. The A.C. and D.C. source allowable out-of-service times are based on Regulatory Guide 1.93, "Availability of Electrical Power Sources," December 1974. There are additional ACTION requirements to verify that all required feature(s) that depend on the remaining OPERABLE A.C.

sources as a source of emergency power, are also OPERABLE. These requirements allow a period of time to restore any required feature discovered to be inoperable, e.g. out-of-service for maintenance, to an OPERABLE status. If the required feature(s) cannot be restored to an OPERABLE status, the ACTION statement requires the redundant required feature, i.e. feature receiving power from an inoperable A.C. source, to be declared inoperable. The allowed operating times to restore an inoperable required feature to an OPERABLE status is based on the requirements in NUREG 1431. The term "verify", as used in these ACTION statements means to administratively check by examining logs or other information to determine the OPERABILITY of required feature(s). It does not mean to perform the Surveillance Requirement needed to demonstrate the OPERABILITY of the required feature(s).

The OPERABILITY of the minimum specified A.C. and D.C. power sources and associated distribution systems during shutdown and refueling ensures that: (1) the facility can be maintained in the shutdown or refueling condition for extended time periods, and (2) sufficient instrumentation and control capability is available for monitoring and maintaining the unit status.

The Surveillance Requirements for demonstrating the OPERABILITY of the diesel generators are based upon the recommendations of Regulatory Guides 1.9, "Selection of Diesel Generator Set Capacity for Standby Power Supplies," December 1979; 1.108, "Periodic Testing of Diesel Revision 2 SHEARON HARRIS - UNIT 1 B 3/4 8-1 Amendment No. 78

3/4.8 ELECTRICAL POWER SYSTEMS BASES Generator Units Used as Onsite Electric Power Systems at Nuclear Power Plants," Revision 1, August 1977 as modified in accordance with the guidance of IE Notice 85-32, April 22, 1985; and 1.137, "Fuel-Oil Systems for Standby Diesel Generators," Revision 1, October 1979. Proper shedding and sequencing of loads are required functions for Emergency Diesel Generator OPERABILITY. Pressure testing of the diesel generator fuel oil piping at 110% of the system design pressure will only be required on the isolable portions of (1) fuel oil transfer pump discharge piping to the day tank, (2) fuel oil supply from the day tank to the diesel vendor-supplied piping, and (3) fuel oil return piping from the diesel vendor-supplied piping to the day tank regulator valve. The exemptions allowed by ASME Code Section XI will be invoked for the atmospheric day tanks and non-isolable piping. The surveillance frequencies are controlled in the Surveillance Frequency Control Program.

The inclusion of the loss of generator potential transformer circuit lockout trip is a design feature based upon coincident logic and is an anticipatory trip prior to diesel generator overspeed. In TS 4.8.1.1.2.f.13, the phrase all diesel generator trips refers to automatic protective trips.

The Surveillance Requirements for demonstrating the OPERABILITY of the station batteries are based on the recommendations of Regulatory Guide 1.129, "Maintenance Testing and Replacement of Large Lead Storage Batteries for Nuclear Power Plants," February 1978, and IEEE Std 450-1980, "IEEE Recommended Practice for Maintenance, Testing, and Replacement of Large Lead Storage Batteries for Generating Stations and Substations." The performance test supporting the Surveillance Requirement incorporates the guidance of IEEE Std 450-2010. The surveillance frequencies are controlled in the Surveillance Frequency Control Program.

Verifying average electrolyte temperature above the minimum for which the battery was sized, total battery terminal voltage on float charge, connection resistance values, and the performance of battery service and discharge tests ensures the effectiveness of the charging system, the ability to handle high discharge rates, and compares the battery capacity at that time with the rated capacity.

Table 4.8-2 specifies the normal limits for each designated pilot cell and each connected cell for electrolyte level, float voltage, and specific gravity. The limits for the designated pilot cells float voltage and specific gravity, greater than 2.13 volts and 0.015 below the manufacturer's full charge specific gravity or a battery charger current that had stabilized at a low value, is characteristic of a charged cell with adequate capacity. The normal limits for each connected cell for float voltage and specific gravity, greater than 2.13 volts and not more than 0.020 below the manufacturer's full charge specific gravity with an average specific gravity of all the connected cells not more than 0.010 below the manufacturer's full charge specific gravity, ensures the OPERABILITY and capability of the battery.

Operation with a battery cell's parameter outside the normal limit but within the allowable value specified in Table 4.8-2 is permitted for up to 7 days. During this 7-day period: (1) the allowable values for electrolyte level ensures no physical damage to the plates with an adequate electron transfer capability; (2) the allowable value for the average specific gravity of all the cells, not more than 0.020 below the manufacturer's recommended full charge specific gravity, ensures that the decrease in rating will be less than the safety margin provided in sizing; (3) the allowable value for an individual cell's specific gravity, ensures that an individual cell's specific gravity will not be more than 0.040 below the manufacturer's full charge specific gravity and that the overall capability of the battery will be maintained within an acceptable limit; and (4) the allowable value for an individual cell's float voltage, greater than 2.07 volts, ensures the battery's capability to perform its design function.

SHEARON HARRIS - UNIT 1 B 3/4 8-2 Amendment No. 154

3/4.8 ELECTRICAL POWER SYSTEMS BASES LCOs 3.8.3.1 and 3.8.3.2 include requirements for energizing 118 VAC vital buses from the associated inverters connected to 125 VDC buses. In the event the 118 VAC vital buses are not energized by the inverters connected to the 125 VDC buses, system design provides for energizing the 118 VAC buses from the Bypass Source or the Alternate Power Supply. The Bypass Source is regulated, transfer to the source is automatic within the inverters, and operation on the Bypass Source requires entry into LCO 3.8.3.1 Action c or LCO 3.8.3.2 Action, depending on the OPERATIONAL MODE. The Alternate Power Supply is unregulated and the voltage may not be sufficient to support loads as documented in calculation E-6007. Operation on the Alternate Power Supply, requires entry into LCO 3.8.3.1 Action b or LCO 3.8.3.2 Action, depending on the OPERATIONAL MODE.

3/4.8.4 ELECTRICAL EQUIPMENT PROTECTIVE DEVICES Containment electrical penetrations and penetration conductors are protected by either deenergizing circuits not required during reactor operation or by demonstrating the OPERABILITY of primary and backup overcurrent protection circuit breakers during periodic surveillance.

The Surveillance Requirements applicable to lower voltage circuit breakers provide assurance of breaker reliability by testing at least one representative sample of each manufacturer's brand of circuit breaker. Each manufacturer's molded case and metal case circuit breakers are grouped into representative samples which are then tested on a rotating basis to ensure that all breakers are tested. If a wide variety exists within any manufacturer's brand of circuit breakers, it is necessary to divide that manufacturer's breakers into groups and treat each group as a separate type of breaker for surveillance purposes. For surveillance 4.8.4.1.a.1.c and 4.8.4.1.a.2, testing of the breakers includes a representative sample of 10% of each type of breaker as described in the table below.

Types 15-Amp(A) 30A-40A 50A 60A 70A-90A 100-110A 125-150A 225A The bypassing of the motor-operated valves thermal overload protection during accident conditions by integral bypass devices ensures that safety-related valves will not be prevented from performing their function. The Surveillance Requirements for demonstrating the bypassing of the thermal overload protection during accident conditions are in accordance with Regulatory Guide 1.106, Thermal Overload Protection for Electric Motors on Motor Operated Valves, Revision 1, March 1977.

Revision 1 SHEARON HARRIS - UNIT 1 B 3/4 8-3 Amendment No. 78

3/4.9 REFUELING OPERATIONS BASES 3/4.9.1 BORON CONCENTRATION The limitations on reactivity conditions during REFUELING ensure that:

(1) the reactor will remain subcritical during CORE ALTERATIONS. and (2) a uniform boron concentration is maintained for reactivity control in the water volume having direct access to the reactor vessel. These limitations are consistent w1th the initial conditions assumed for the boron dilution incident in the safety analyses and are specified in the cycle-specific COLR. The boron concentration limit specified in the COLR ensures that a core Ke" of

~ 0.95 is maintained during fuel handling OQerations. The administrative controls over the required valves during refueling ooerations precludes the possibility of uncontrolled boron dilut1on of the filled portion of the RCS.

This action prevents flow to the RCS of unborated water by closing flow paths from sources of unborated water.

3/4.9.2 INSTRUMENTATION The OPERABILITY of the Source Range Neutron Flux Monitors and/or Wide Range Neutron Flux Monitors ensures that redundant monitoring capability is available to detect changes in the reactivity condition of the core. If the audible indication is lost. then enter LCD Action 3.9.2.b.

3/4.9.3 DECAY TIME - DELETED 3/4.9.4 CONTAINMENT BUILDING PENETRATIONS The requirements on containment building penetration closure and OPERABILITY ensure that a release of radioactive material within containment will be restricted from leakage to the environment. The OPERABILITY and closure restrictions are suff1cient to restrict radioactive material release from a fuel element rupture based uEon the lack of containment pressurization potential while in the REFUE ING MODE. Penetrations applicable to Technical Specification 3.9.4.b and 3.9.4.c may be opened provided the following administrative controls are in effect:

1. An individual or individuals shall be designated and available at all times. capable of isolating the breached penetration.
2. The breached penetrations shall not be obstructed unless capability for rapid removal of obstructions is provided (such as quick disconnects for hoses).
3. For the Personnel Air Lock. at least one door must be capable of being closed and secured. Additionally. the equipment hatch must be capable of being closed and secured. Equivalent isolation methods may also be used.

The LCD is modified by a Note allowing penetration flow paths providing direct access from the containment atmosphere to the outside atmosphere to be open under administrative controls. Administrative controls ensure that 1) appropriate personnel are aware of the open status of the penetration flow path during CORE ALTERATIONS or movement of irradiated fuel assemblies within containment. and 2) specified individuals are designated and readily available to isolate the flow path in the event of a fuel handling accident.

SHEARON HARRIS - UNIT 1 B 3/4 9-1 Amendment No. 105

REFUELING OPERATIONS BASES CONTAINMENT BUILDING PENETRATIONS (Continued)

The allowance to have containment penetration (including the airlock doors and equipment hatch) flow paths with direct access from the containment atmosphere to the outside atmosphere to be unisolated during fuel movement and CORE ALTERATIONS is based on (1) confirmatory dose calculations as approved by the NRC staff which indicate acceptable radiological consequences and (2) commitments from the licensee to implement acceptable administrative procedures that ensure in the event of a refueling accident that the airlock or equipment hatch can and will be promptly closed following containment evacuation (even though the containment fission product control function is not required to meet acceptable dose consequences) and that the open penetration(s) can and will be promptly closed. The time to close such penetrations or combination of penetrations shall be included in the confirmatory dose calculations.

Containment penetrations that provide direct access from containment atmosphere to outside atmosphere must be isolated, or capable of isolation via administrative controls, on at least one side of containment. Isolation may be achieved by an OPERABLE automatic isolation valve, or by a manual isolation valve, blind flange, or equivalent. Equivalent isolation methods include use of a material that can provide a temporary, atmospheric pressure, ventilation barrier for the other containment penetrations during fuel movement.

3/4.9.5 COMMUNICATIONS - DELETED 3/4.9.6 REFUELING MACHINE - DELETED 3/4.9.7 CRANE TRAVEL - FUEL HANDLING BUILDING - DELETED 3/4.9.8 RESIDUAL HEAT REMOVAL AND COOLANT CIRCULATION The requirement that at least one residual heat removal (RHR) loop be in operation ensures that:

(1) sufficient cooling capacity is available to remove decay heat and maintain the water in the reactor vessel below 140°F as required during the REFUELING MODE, and (2) sufficient coolant circulation is maintained through the core to minimize the effect of a boron dilution incident and prevent boron stratification.

The requirement to have two RHR loops OPERABLE when there is less than 23 feet of water above the reactor vessel flange ensures that a single failure of the operating RHR loop will not result in a complete loss of residual heat removal capability. With the reactor vessel head removed and at least 23 feet of water above the reactor pressure vessel flange, a large heat sink is available for core cooling. Thus, in the event of a failure of the operating RHR loop, adequate time is provided to initiate emergency procedures to cool the core.

The minimum RHR flow requirement is reduced to 900 gpm when the reactor water level is below the reactor vessel flange. The 900 gpm limit reduces the possibility of cavitation during operation of the RHR pumps and ensures sufficient mixing in the event of a MODE 6 boron dilution incident.

Management of gas voids is important to RHR System OPERABILITY. RHR System piping and components have the potential to develop voids and pockets of entrained gases. Preventing and managing gas intrusion and accumulation is necessary for proper operation of the RHR loops and may also prevent water hammer, pump cavitation, and pumping of noncondensible gas into the reactor vessel.

Surveillance Requirements verify that required RHR loop locations susceptible to gas accumulation are sufficiently filled with water. Selection of RHR System locations susceptible to gas accumulation is based on a review of system design information, including piping and instrumentation drawings, isometric drawings, plan and elevation drawings, and calculations. The design review is supplemented by system walk downs to validate the system high points and to SHEARON HARRIS - UNIT 1 B 3/4 9-2 Amendment No. 150

REFUELING OPERATIONS BASES RESIDUAL HEAT REMOVAL AND COOLANT CIRCULATION (Continued) confirm the location and orientation of important components that can become sources of gas or could otherwise cause gas to be trapped or difficult to remove during system maintenance or restoration. Susceptible locations depend on plant and system configuration, such as stand-by versus operating conditions.

The RHR System is OPERABLE when it is sufficiently filled with water. Acceptance criteria are established for the volume of accumulated gas at susceptible locations. If accumulated gas is discovered that exceeds the acceptance criteria for the susceptible location (or the volume of accumulated gas at one or more susceptible locations exceeds an acceptance criteria for gas volume at the suction or discharge of a pump), the Surveillance is not met. If it is determined by subsequent evaluation that the RHR System is not rendered inoperable by the accumulated gas (i.e., the system is sufficiently filled with water), the Surveillance may be declared met.

Accumulated gas should be eliminated or brought within the acceptance criteria limits. If any accumulated gas is eliminated or brought within the acceptance criteria limits as part of the Surveillance performance, the Surveillance is considered met and the system is OPERABLE.

Past operability is then evaluated under the Corrective Action program. If it is suspected that a gas intrusion event is occurring, then this is evaluated under the Operability Determination Process.

RHR System locations susceptible to gas accumulation are monitored and, if gas is found, the gas volume is compared to the acceptance criteria for the location. Susceptible locations in the same system flow path which are subject to the same gas intrusion mechanisms may be verified by monitoring a representative sub-set of susceptible locations. Monitoring may not be practical for locations that are inaccessible due to radiological or environmental conditions, the plant configuration, or personnel safety. For these locations alternative methods (e.g., operating parameters, remote monitoring) may be used to monitor the susceptible location. Monitoring is not required for susceptible locations where the maximum potential accumulated gas void volume has been evaluated and determined to not challenge system OPERABILITY. The accuracy of the method used for monitoring the susceptible locations and trending of the results should be sufficient to assure system OPERABILITY during the Surveillance interval.

3/4.9.9 CONTAINMENT VENTILATION ISOLATION SYSTEM The OPERABILITY of this system ensures that the containment purge makeup and exhaust penetrations will be automatically isolated upon detection of high radiation levels within the containment. The OPERABILITY of this system is required to restrict the release of radioactive material from the containment atmosphere to the environment.

SHEARON HARRIS - UNIT 1 B 3/4 9-2a Amendment No. 150

REFUELING OPERATIONS BASES CONTAINMENT VENTILATION ISOLATION SYSTEM (Continued)

Penetrations applicable to Technical Specification 3.9.9 may be opened provided the following administrative controls are in effect:

1. An individual or individuals shall be designated and available at all times. capable of isolating the breached penetration.
2. The breached penetration shall not be obstructed unless capability for rapid removal of obstructions is provided (such as quick disconnects for hoses).

The LCD is modified by a Note allowing penetration flow paths providing direct access from the containment atmosphere to the outside atmosphere to be open under administrative controls. Administrative controls ensure that 1) appropriate personnel are aware of the open status of the penetration flow path during CORE ALTERATIONS or movement of irradiated fuel assemblies within containment. and 2) specified individuals are designated and readily available to isolate the flow path in the event of a fuel handling accident.

The allowance to have containment penetration (including the airlock doors and equipment hatch) flow paths with direct access from the containment atmosphere to the outside atmosphere to be unisolated during fuel movement and CORE ALTERATIONS is based on 1) confirmatory dose calculations as approved by the NRC staff which indicate acceptable radiological consequences and 2) commitments from the licensee to implement acceptable administrative procedures that ensure in the event of a refueling accident that the airlock or equipment hatch can and will be promptly closed following containment evacuation (even though the containment fission product control function is not required to meet acceptable dose consequences) and the open penetration(s) can and will be promptly closed. The time to close such penetrations or combination of penetrations shall be included in the confirmatory dose calculations.

3/4.9.10 AND 3/4.9.11 WATER LEVEL - REACTOR VESSEL AND NEW AND SPENT FUEL POOLS The restrictions on minimum water level ensure that sufficient water depth is available to remove 99% of the assumed iodine gap activity released from the rupture of an irradiated fuel assembly. The minimum water depth is consistent with the assumptions of the safety analysis.

According to Regulatory Guide 1.25. Revision 0. there is 23 feet of water between the top of the damaged fuel bundle and the fuel pool surface during a fuel handling accident. With 23 feet of water. the assumptions of Regulatory Guide 1.25. Revision 0. can be used directly. In practice. this LCD preserves this assumption for the bulk of the fuel in the storage racks. In the case of a single bundle dropped and lying horizontal on top of the spent fuel racks:

however. there may be <23 feet of water above the top of the fuel bundle and the surface. indicated by the width of the bundle. To offset this small nonconservatism. the analysis assumes that all fuel rods fail.

SHEARON HARRIS - UNIT 1 B 3/4 9-3 Amendment No. 113

REFUELING OPERATIONS BASES 3/4.9.12 FUEL HANDLING BUILDING EMERGENCY EXHAUST SYSTEM The limitations on the Fuel Handling Building Emergency Exhaust System ensure that all radioactive material released from an irradiated fuel assembly will be filtered through the HEPA filters and charcoal adsorber prior to discharge to the atmosphere. Operation for 15 continuous minutes demonstrates OPERABILITY of the system. Periodic operation ensures that blockage, fan or motor failure, or excessive vibration can be detected for corrective action. The heaters are not required for OPERABILITY since the carbon laboratory tests are performed at 95% relative humidity, but are maintained in the system to provide additional efficiency margin. The surveillance frequency is controlled under the Surveillance Frequency Control Program. The OPERABILITY of this system and the resulting iodine removal capacity are consistent with the assumptions of the safety analyses. ANSI N510-1980 will be used as a procedural guide for surveillance testing. Criteria for laboratory testing of charcoal and for in-place testing of HEPA filters and charcoal adsorbers is based upon removal efficiencies of 95% for organic and elemental forms of radioiodine and 99% for particulate forms. The filter pressure drop was chosen to be half-way between the estimated clean and dirty pressure drops for these components. This assures the full functionality of the filters for a prolonged period, even at the Technical Specification limit.

The LCO is modified by a note allowing the Fuel Handling Building Emergency Exhaust System (FHBEES) ventilation boundary to be opened intermittently under administrative controls. For entry and exit through doors, the administrative control of opening is performed by the person(s) entering or exiting the area. For other openings, these controls consist of stationing a dedicated individual at the opening who is in continuous communication with the control room. This individual will have a method to rapidly close the opening when a need for FHBEES isolation is indicated.

SHEARON HARRIS - UNIT 1 B 3/4 9-4 Amendment No. 170

3/4.lO SPECIAL TEST EXCEPTIONS BASES 3/4.10.l SHUTDOWN MARGIN This special test excepti_on provides that a minimum amount of shutdown and c:on-tral rod worth fs ia111ediately available far reactivity control when tests ara performed for cant'l'"Ol rod worth measurement. This special test exception is nquired to permit the periodic verification of the actual versus predicted ca.,..- reactivity condition occurring as a result cf fuel burnup or fuel cycling operations. .

3/4.10.2 GROUP HEIGHT. INSERTION. AND POWER DISTRIBUTION LIMITS This s~ecfal test exception permits f~dividual shutdown and control l"Ods tab~

positioned outside of tbeir.narmal g'l'"OIJ? heights and insert.ion limits during the performance of such PHYSICS TESTS as those required to: (l) measure shut-down and control rod worth, and (Z) determine the reactor stability index and damping factor under xenon oscillation conditions. .

  • 3/4.10.3 PHYSICS TESTS This special test exception permits PHYSICS TESTS ta be performed at less than or equal ta ~ of RATED THERMAL PO"'ER with the RCS Tavg slightly lower than normally allowed so that the fundamental nuclear-*charactaristics of tne care and related instrumentation can be verified. In al"der for*variaus character-istics to be accurately measured, it is at times necessary to operate outside the normal restrjctians af these Technical Specifications. Fa~ instance, to measure the moderator temperature coefficient at BOL, it is necessary ta pasi*

t1on the various cantl"Ol rods at heights which may not normally be allowed by Specification 3.1.3.6 which i(l ~n, 11ay cause the RCS Tavg ta fall slightly

  • ~.

below the 11ini111U11 temperature cf Spacificatian 3.l.1.4.

3/4.10.4 REACTOR COOLANT LOOPS This S1:Jecial test exception permits reac:tar criticality under no flow conditions and is required ta perform certain STARTUP and PHYSICS TESTS while at low

. . ";j THERMAL POWER levels.

3/4.10. 5 POsmoN INDICATION SYSTEM

  • SHUTDOWN This si,ecial tut exception per11its th* P1,s1tion Indication Systems ta be in-operable. during rod drop ti* 11NSuraents. The exception fs l"lquired since the data necessary to determine the rod~ t i
  • an de'l'"ived fl"OII the induced

~voltage in th* position indicator coils u the*l"Od is drop~ed. This induced voltage is small compared ta th* normal voltage and, therefore, cannot be observed if the Position Indication Systams remain O~ERASLE.

SHEARON HARRIS* UNIT 1 a 3/410-1

.. ------a..--*-*----- - . *--. -- ...

.,. ...... -~~--***~-~ .*. -,**-*-*-***-* - .* ~-- -- --- . , .. ..- ~- ... '* *.-

3/4.11 RADIOACTIVE EFFLUENTS BASES 3/4.11.1 LIQUID EFFLUENTS 3/4.11.1.1 DELETED 3/4.11.1.2 DELETED 3/4.11.1.3 DELETED 3/4.11.1.4 DELETED 3/4.11.2 GASEOUS EFFLUENTS 3/4.11.2.1 DELETED 3/4.11.2.2 DELETED 3/4.11.2.3 DELETED 3/4.11.2.4 DELETED 3/4.11.2.5 DELETED SHEARON HARRIS - UNIT 1 B 3/4 11-1 Amendment No. 159

RADIOACTIVE EFFLUENTS BASES 3/4.11.2.6 DELETED 3/4.11.3 DELETED 3/4.11.4 DELETED f

Pages B 3/4 11*3 through B 3/4 11*6 have been deleted.

SHEARON HARRIS

  • UNIT 1 B 3/4 11*2 Amendment No. 64

3/4.12 RADIOLOGICAL ENVIRONMENTAL MONITORING BASES 3/4.12.1 DELETED 3/4.12.2 DELETED 3/4.12.3 DELETED Page B 3/4 12-2 has been deleted.

SHEARON HARRIS - UNIT 1 B 3/4 12-1 Amendment No. 58