UFSAR Rev 61, Drawings Part 1
ML18337A379
Person / Time
Site: Harris 
(NPF-63)
Issue date: 05/10/2017
From: Hamilton T
Duke Energy Progress
To:
Office of Nuclear Reactor Regulation
Barillas M DORL/LPL2-2 301-415-2760
Shared Package
ML18337A205 List:
References
HNP-17-029
Download: ML18337A379 (31)


Text

1 2 3

4 5

6 7

8 9

10 11 12 13 14 15 16 17 18 19 N

M L

K J

I H

G F

E D

C B

A 1 2 3

4 5

6 7

8 9

10 11 12 13 14 15 16 17 18 19 10 REV DATE DESCRIPTION TITLE:

NUCLEAR ENGINEERING DEPARTMENT - RALEIGH, N.C.

DWG NO.

SCALE:

PLANT:

NUCLEAR SAFETY RELATED (Q-LIST)

THIS DRAWING HAS BEEN PRODUCED AND IS CONTROLLED ON THE NED CAD/E SYSTEM. ANY REVISIONS TO THIS DOCUMENT SHOULD BE DONE USING THE CAD/E SYSTEM TO ASSURE PROPER CONTROL OF THE ELECTRONIC DRAWING DATABASE.

CAR-2165-HARRIS NUCLEAR PROJECT - UNIT 1 NONE M

N L

K J

I H

G F

E D

C B

A CHK DWN CAR-2165-G-0041 THIS DRAWING HAS BEEN ELECTRONICALLY YES NO PARTIAL F.P.-Q R.W.-Q APPR'D CURB BOX VALVE GATE VALVE (DOUBLE DISC)

GATE VALVE NEEDLE VALVE GLOBE VALVE PLUG VALVE DIAPHRAGM VALVE BUTTERFLY VALVE REVERSE CURRENT VALVE CHECK VALVE M

VALVE MOTOR OPERATED VALVE PISTON OPERATED S

VALVE SOLENOID OPERATED S

OPERATED VALVE THREE-WAY SOLENOID 4

T G

G EH OPERATED VALVE AIR DIAPHRAGM REGULATOR SELF CONTAINED POST INDICATOR CONNECTION VALVE WITH LEAKOFF OPERATOR EXTENSION STEM VALVE SAFETY AND RELIEF ANGLE VALVE THREE WAY VALVE FOUR WAY VALVE WITH VALVE POSITIONER PROCESS ACTUATED OPERATOR NORMALLY CLOSED VALVE NORMALLY OPEN VALVE FLOW OVER SEAT VALVE INSTALLED WITH PACKLESS VALVE BALL VALVE NUMBER EQUIPMENT CONNECTION AUTOMATIC AIR VENT TURBINE STOP VALVE CONTROL VALVE TURBINE GOVERNING STOP CHECK VALVE TUBE OR VENTURI FLOW METERING LOW LOSS FLOW NOZZLE GEAR OPERATOR-MANUAL OPERATOR ELECTRO-HYDRAULIC CHECK VALVE EXCESS FLOW S

F Y

T V

V x

x x

x M

59 M

STRAINER Y-STRAINER FILTER OR FUNNEL OPEN DRAIN STEAM TRAP VENT ATMOSPHERIC VACUUM BREAKER FIRE HYDRANT WELDED CAP SCREWED OR SOCKET BUTT WELDED CAP TEMPORARY CONNECTION BLIND FLANGE OR VESSEL MANWAY EXPANSION JOINT RUPTURE DISC OR ORIFICE FLOW RESTRICTION REDUCER THERMAL SLEEVE SPECTACLE FLANGE COUPLING QUICK DISCONNECT DIAPHRAGM SEAL STEAM OR ELECTRICAL HEATER (TRAP)

LOOP SEAL (INSIDE VESSELS)

SPARGER (INSIDE VESSEL)

SPRAY NOZZLES (AIR OR ELECTRICAL)

MIXER (PIPING OR EQUIPMENT)

FLANGE CONNECTION JOHNSON SCREEN EDUCTOR BLENDER CONNECTION FLEXIBLE PENETRATION MECHANICAL CONTAINMENT PLATE TYPE CONE TYPE TEE TYPE STRAINERS TEMPORARY DRAIN POT DAMPENER PULSATION ORIFICE BREAK-DOWN DRAIN PUMP BEDPLATE (BELLOWS TYPE SEAL)

SENSOR FLOW SIGHT GAGE SLUICE GATE EYEWASH & SHOWER RAM SEAL VALVE PIPE PLUG GAS BOTTLE OR CYLINDER SAMPLE VESSEL OR BOTTLE GUARD PIPE PIPE-TO-TUBING ADAPTER THERMOWELL VALVE & SPECIALTY SYMBOLS LINE CODING INSIDE OUTSIDE X

X X

X X

SHIELD WALL PENETRATION TUBE AND/OR CAPILLARY TUBING FILLED BULB TEMPERATURE DETECTOR PIPING FURNISHED WITH EQUIPMENT INSTRUMENTATION SYMBOLS FI FE DETAIL CAR-2166-B-431 SEE INSTRUMENT INSTALLATION REFERENCE BLOCK REFERENCE SYSTEM OR TERMINATION DESCRIPTION OF SOURCE REFERENCE DRAWING NO.

FLOW DIRECTION OF COORDINATES DRAWING GENERAL NOTES RECORDING INDICATING NON INDICATIONG CONTROL VALVE SUMMER SOLENOID FUNCTION GENERATOR RECORDING INDICATING OBSERVATION GLASS PRIMARY ELEMENT TEST POINT TRANSMITTER INTEGRATOR (TRANSMITTER)

AMPLIFIER SAMPLER INDICATING SWITCH NON INDICATING SWITCH ALARMS (SECOND AND THIRD LETTER)

CONTROLLING (SECOND AND THIRD LETTER)

MEASURING

-RC

-IC

-C

-CV

-SE

-F

-R

-I

-G

-E

-W

-X OR

-T Q

QT Am Sm IS

-S

-A CRC DRC PDRC FRC MRC DIFFERENTIAL LEVEL INSTRUMENT FUNCTION (FIRST LETTER)

VARIABLE MEASURED CONDUCTIVITY DENSITY DIFF PRESS FLOW MOISTURE HYDROGEN ION COND LEVEL OXYGEN PRESSURE POSITION RADIATION SPEED TEMPERATURE HYDROGEN NITROGEN VIBRATION HAND WEIGHT OR FORCE ANALYSIS TIME SELF REGULATING VALVE C

D PD F

M pH L

O2 P

Z R

S T

H2 N2 V

H W

A K

LD pHRC LRC PRC SPC TPC HIC TIC SIC PIC LIC pHIC MIC FIC PDIC DIC CIC DC PDC FC pHC LC PC SC TC RCV HCV TCV PCV LCV pHCV FCV PDCV DCV CCV F

HSE PSE LSE FSE Ff CR DR PDR FR MR pHR LR O2R PR ZR RR SR TR CI DI FI MI LI PI ZI RI SI TI PDI pHI O2I FG LG CE CX CSm CIS CS CA DX DIS DS DA PDT PDIS PDS PDA FE FX FT FQ FQT FIS FS FA ME pHE pHX pHAm pHSm pHA LE LX LT LIS LS LA O2E PX PT PIS PS PA ZT ZS ZA RE REM RX RAm RSm RS RA SE TE TW TT TIS TS TA HS LDS AT AX AE MISCELLANEOUS ABBREVIATIONS EQUIPMENT ABBREVIATIONS T -

CA -

(S SIGNAL OR MANUAL)

TRIP SIGNAL PHASE A CONTAINMENT ISOLATION CONTAINMENT AIR LOCKED AS IS ECC -

CONNECTION EMERGENCY COOLING BD -

SIGNAL THERMAL REGENERATION BOP - BALANCE OF PLANT NR -

NOT RELEASED NTS - NOT TO SCALE BY OTHERS BF -

BY FIELD R -

FROM CONTROL ROOM REMOTELY CONTROLLED ATM -

F.A.I. -

ATMOSPHERE FAIL AS IS F.C. - FAIL CLOSED F.O. - FAIL OPEN L.C. -

L.O. -

N.C. -

N.O. -

LOCKED CLOSED LOCKED OPEN NORMALLY CLOSED NORMALLY OPEN VH -

V -

PV -

VENT HEADER PLANT VENT SSE -

MFIS -

MSIS -

SAFE SHUTDOWN EARTHQUAKE MAIN FEEDWATER ISOLATION SIGNAL MAIN STEAM ISOLATION SIGNAL S -

PLACED AT EQUIPMENT & VALVE SAFETY INJECTION SIGNAL-IMB -

INSIDE MISSILE BARRIER OMB -

OUTSIDE MISSILE BARRIER RR -

REACH ROD REQUIRED P -

(HI-HI CONTAINMENT PRESS)

CONTAINMENT ISOLATION TRIP PHASE B IRC -

INSIDE REACTOR CONTAINMENT ORC -

OUTSIDE REACTOR CONTAINMENT DC -

RWST -

REFUELING WATER STORAGE TANK SRST - SPENT RESIN STORAGE TANK PRT -

PRESSURIZER RELIEF TANK WHT -

WASTE HOLDUP TANK CS -

CONTAINMENT SUMP RHT -

RECYCLE HOLDUP TANK CCDT -

COMPONENT COOLING DRAIN TANK FDT -

FLOOR DRAIN TANK BRP -

BORON RECYCLE PANEL HX -

HEAT EXCHANGER BIT -

BORON INJECTION TANK RCPS -

REACTOR CONTROL & PROTECTION SYSTEM RCDT -

REACTOR COOLANT DRAIN TANK RMWST - REACTOR MAKE-UP WATER STORAGE TANK CST -

CONDENSATE STORAGE TANK MSR -

MOISTURE SEPARATOR REHEATER CRDM -

CONTROL ROD DRIVE MECHANISM GSC -

GLAND STEAM CONDENSER RCP -

REACTOR COOLANT PUMP PIPING SYSTEM DESIGNATIONS LETTER SYSTEM LETTER SYSTEM DESCRIPTION SYSTEM DESCRIPTION SYSTEM EQUIPMENT UNIT NUMBER INSTRUMENTATION PARALLEL DESIGNATION SEISMIC DESIGNATION INSTRUMENT IDENTIFICATION NUMBER SUB-PARALLEL DESIGNATION AI 2051 PI S

G-0041 LLS WITH VALVE POSITIONER INSTRUMENT ACTUATED OPERATOR (A5)

CAR-2165-G-050 SI PUMP L.A.I. -

VITAL BATTERY SOURCE OF POWER ELECTRICAL HEAT TRACING VENDOR MANUFACTURER OR NSSS FURNISHED BY EQUIPMENT WITH HOSE(BY FIELD)

HOSE CONNECTION FLOW LIMITER (OUT OF SYSTEM DASHED)

MAIN FLOW LINES (OUT OF SYSTEM DASHED)

SECONDARY FLOW LINES (ELECTRICAL)

INSTRUMENT LINES (IMPULSE)

INSTRUMENT LINES (PNEUMATIC) iNSTRUMENT LINES EBASCO BY OTHERS SPLIT OF RESPONSIBILITY (NSSS ONLY)

SS CS MATERIAL TRANSITION VALVE & SPECIALTY DESIGNATIONS CURB BOX VALVE FLEXIBLE METAL HOSE MISCELLANEOUS FLOW LIMITERS RESTRICTION ORIFICES FLOW CONTROL VALVES TEMPERATURE-CONTROL VALVES PRESSURE CONTROL VALVES LEVEL CONTROL VALVES DIAPHRAGM VALVES ANGLE VALVES BALL VALVES NEEDLE VALVES STRAINERS - SELF-CLEANING STRAINERS TRAPS EXPANSION JOINTS SAFETY AND RELIEF VALVES PLUG VALVES BUTTERFLY VALVES THREE-WAY VALVES REVERSE CURRENT VALVES CHECK VALVES GLOBE VALVES GATE VALVES Z

I X

K U

F M

P L

D A

H N

E S

T J

R G

B W

C V

V V

FOR INSTALLATION REQUIREMENTS.

TO ORIFICE SPECIFICATION SHEET CONTRACTA TAPS OR OTHER. REFER METER. MAY HAVE FLANGE TAPS, VENA TYPICAL ONLY-ORIFICE TYPE FLOW BY INSTRUMENTATION VENT TO ATMOSPHERE EQUIPMENT, VALVES, SPECIALTIES, PIPING & INSTRUMENTS NUMBERING 1A-SA

("X" DESIGNATES ONE ONLY)

DESIGNATION LETTER EQUIPMENT MULTIPLICITY "N" DESIGNATES NON SAFETY TRAIN TRAIN (SAFETY RELATED EQUIPMENT ONLY)

DESIGNATED BY "NNS" NON-NUCLEAR SAFETY EQUIPMENT WILL BE DESIGNATED BY AN "S" SAFETY RELATED EQUIPMENT WILL BE VALVES AND SPECIALTIES 3SW-V3SA-1 SYSTEM CATEGORY EBASCO PIPING SYSTEM SYMBOL VALVE OR SPECIALTY SYMBOL VALVE OR SPECIALTY UNIQUE NUMBER NON SAFETY TRAIN SPECIALTIES ONLY) "N" DESIGNATES TRAIN (SAFETY RELATED VALVES AND UNIT NUMBER WILL BE DESIGNATED BY AN "S" SAFETY RELATED VALVES & SPECIALTIES PIPE 2MS30-120SA-1 SYSTEM CATEGORY EBASCO PIPING SYSTEM SYMBOL LINE SIZE (INCHES)

LINE NUMBER "N" DESIGNATES NON SAFETY TRAIN TRAIN (SAFETY RELATED LINES ONLY)

UNIT NUMBER INSTRUMENT TYPE SYSTEM SYMBOL UNIT NUMBER BALLOON REPRESENTATION (OMITS UNIT NUMBER & SYSTEM SYMBOL)

AI 2051 PI AW IIW OR TYPICAL DETAIL TEST CONN, TEST VENT, ETC.)

(DRAIN, VENT, SAMPLE CONN, SAFETY CLASS OPEN-ENDED PIPING 1, 2 OR 3 CATEGORY PER FLOW DIAGRAM 1 OR 2 VALVES

& TEST PRESSURE SAME OPERATING SAMPLE LINE NUMBER ASME III SPECS B31.1 SPECS TYPICAL ORIFICE FLANGE CONNECTION BELOW 900# PRESSURE RATING 1 X * (FOR B.O.P.)

f X * (FOR NSSS) 900# & ABOVE 1 X f (FOR B.O.P.)

f LINE (NO REDUCER)(FOR NSSS)

FOR LINE & VALVE NUMBERS SEE RESPECTIVE DIAGRAMS VALVED AS SHOWN ON FLOW DIAGRAM.

ALL VENTS, DRAINS, AND TEST CONNECTIONS SHALL BE CAPPED (AS REQUIRED).

PERMANENTLY PIPED TO THE APPROPRIATE DRAIN POINT OR ALL VALVES PURCHASED WITH LEAKOFF CONNECTIONS SHALL BE DESIGNATED BY THE FOLLOWING FLAGS:

THE SAFETY CLASS BOUNDARIES FOR PIPING AND VALVES ARE 1

2 3

SAFETY CLASS 1 SAFETY CLASS 2 SAFETY CLASS 3 NON-NUCLEAR SAFETY CLASS (NNS) 1 2

BOUNDARY BETWEEN CLASS 1 & 2 ON GENERAL ARRANGEMENT DRAWINGS SAFETY CLASS EQUIPMENT SHALL BE SHOWN WITH HATCH LINES FROM SAFETY CLASS 1 TO SAFETY CLASS 2 THE FLOW DIAGRAMS IN f INCH PIPING, TO ALLOW TRANSITION (WATER LINES) AT LOCATIONS SPECIFICALLY INDICATED ON IN SAFETY CLASS 1 PIPING, A FLOW RESTRICTION IS REQUIRED, 0.375" 1 2 FOR 0.375" I.D.

TO 6000 LB. ASA HALF COUPLING DRILLED f" SOCKET WELD CONNECTION EQUIVALENT TYPICAL FLOW RESTRICTOR INSIDE DIAMETER TO 0.375".)

THE FLOW AREA BY REDUCING THE CONNECTION CRITERIA AND RESTRICT THEY CONFORM TO PIPE BRANCH ACCEPTABLE WHERE NECESSARY PROVIDED (DEVIATIONS FROM THIS DESIGN ARE END SHALL BE MACHINED TO MATCH THE LESSER WALL SCHEDULE.

WALL SCHEDULE MUST BE USED FOR THE TRANSITION PIPE AND ONE ACCEPTABLE TO USE COMPONENTS AS THE TRANSITION. THE HEAVIER EXISTS BETWEEN SYSTEM PIPING AND COMPONENTS. IT IS NOT TRANSITION PIECES MUST BE PROVIDED IF A SCHEDULE DIFFERENCE CLASSIFICATION OF INSTRUMENTATION IS DEFINED ON CAR-2166-B-431.

APPROPRIATE INSTRUMENT INSTALLATION DETAILS CAR-2166-B-431.

AND INTERLOCKS, SEE THE CORRESPONDING W FLOW DIAGRAM OR INSTRUMENT PRIMARY ELEMENT. FOR THE COMPLETE INSTRUMENT LOOP INSTRUMENTATION SHOWN ON FLOW DIAGRAMS REPRESENT ONLY THE 6.

7.

8.

5.

4.

3.

2.

1.

REFERENCE DRAWINGS DETAILS INSTRUMENT INSTALLATION INSTRUMENT LIST VALVE & SPECIALTY LIST PIPING LINE LIST CAR-2166-B-431 CAR-2166-B-432 CAR-1364-B-069 CAR-1364-B-070 REDRAWN WITHOUT DESIGN CHANGE PIPING & INSTRUMENTATION SYMBOLS FLOW DIAGRAM LEGEND ARRANGEMENT MAY DIFFER FROM THAT DEPICTED BY THE FLOW DIAGRAM.

REPRESENTATION OF DESIGN FUNCTIONS. THE PLANT PHYSICAL BREAKS AND FLOWPATHS ARE DEPICTED TO PROVIDE AN ACCURATE VALVE AND LINE NUMBERS/SIZES, INSTRUMENTATION DETAILS, CLASS FLOW DIAGRAMS PROVIDE A FUNCTIONAL REPRESENTATION OF THE SYSTEM.

BE DESIGNATED BY AN "S" SAFETY RELATED PIPE WILL (IF APPLICABLE)

SUPPLIED BY WESTINGHOUSE (NSSS)

(A, B, AB, OR I, II, III, IV)

SAFETY TRAIN OR CHANNEL DESIGNATION 3/6/97 RPP DLS DLS SIGNED ELECTRONICALLY REVISED PER EC# 59498 THIS DRAWING HAS BEEN 11 PI 1 MS 2051 A1 SA W AC AE AF AS ASI ACD BD BR CA CB CC CCD CE CF CG CH CL CM CO CP CS CT CW CX DW EA ED ES FD FM FO FP FW AUXILIARY STEAM CONDENSATE AIR EVACUATION AUXILIARY FEEDWATER AUXILIARY STEAM ALTERNATE SEAL INJECTION ACID-CAUSTIC DRAIN BLOWDOWN BORON RECYCLE CAUSTIC & ACID CONTAINMENT BLDG VACUUM RELIEF (HVAC)

COMPONENT COOLING WATER COMPONENT COOLING DRAIN CONDENSATE CHEMICAL FEED CARBON DIOXIDE CHILLED WATER SUPPLY (HVAC)

CHLORINATION CONTAINMENT BLDG HYDROGEN CONTROL (HVAC)

COMPRESSED AIR CONTAINMENT BLDG PURGE (HVAC)

CHEMICAL & VOLUME CONTROL CONTAINMENT SPRAY CIRCULATING WATER CHILLED WATER RETURN (HVAC)

DEMINERALIZED WATER EMERGENCY AIR EQUIPMENT DRAIN EXTRACTION STEAM FLOOR DRAIN PRIMARY FILTER MAKE-UP WATER FUEL OIL FIRE PROTECTION FEEDWATER HD HV HY IA LO LT LU MD MP MS NI OX PM PP PW RC RH SA SC SDG SF SI SP SW TB VA VL WC WCD WG WL WS WSD HEATER DRAIN HEATER VENTS HYDROGEN INSTRUMENT AIR LUBE OIL LEAK RATE TESTING STEAM GENERATOR WET LAY-UP MISCELLANEOUS DRAINS MAKE-UP PLANT WATER MAIN STEAM NITROGEN OXYGEN PRIMARY MAKE-UP WATER PENETRATION PRESSURIZATION POTABLE WATER REACTOR COOLANT RESIDUAL HEAT REMOVAL SERVICE AIR SCREEN WASH SHUTDOWN DIESEL GENERATOR SPENT FUEL POOL COOLING & CLEANUP SAFETY INJECTION SAMPLING (NUCLEAR), RADIATION MONITORING SERVICE WATER TOWER BLOWDOWN (COOLING TOWER)

VACUUM SYSTEM (LABORATORIES)

VALVE LEAKOFF WPB COOLING WATER WPB COOLING WATER DRAIN WASTE PROCESSING (GAS)

WASTE PROCESSING (LIQUID)

SECONDARY WASTE TREATMENT SECONDARY WASTE TREATMENT DRAIN SIGNED ELECTRONICALLY 12 INCORPORATED: EC 78036 (J8,K11)

FOOT/FLOAT VALVE 13 SIGNED ELECTRONICALLY INCORPORATED: EC 294610 (A3)

DUKE ENERGY

STEAM GENERATOR 1A-SN M

3 1C-SN GENERATOR STEAM STEAM GENERATOR 1B-SN 2

M 1

M S

S B G

L.O.

T 4"

12 13 TO ATMOSPHERE (TYP.)

2 2

2 2

2 DRIP PAN (TYP. OF 15)

ABOVE SEAT DRAIN (TYP. OF 15)

(TYP. OF 15)

(TYP. OF 15)

TUBING RELIEF VALVE & DRIP PAN DRAIN ARRG'T (TYP. 3 PLACES)

(EXCEPT AS NOTED)

(TYP)

T F.C.

(TYP) 2 2

F.C.

T 2

2 2

2 2

F.C.

T 2

2 2

2 2

INSIDE REACTOR CONTAINMENT OUTSIDE REACTOR CONTAINMENT TUBING FD TUBING SEE DET. 3 FD SEAT DRAIN G

5MS-T2-1 5MS-T1-1 TURBINE 1X-SB 10 FD 6MS-T3-1 STEAM GENERATOR AUX. FEED PUMP (TURBINE DRIVEN)

PUMP 1X-SAB FLOOR DRAIN CAR-2165-G-044 (M13) 6" MIN.

GLAND & L.P. STEAM LEAK-OFF DRAIN VENT TO ATMOS.

1" FD AUX. FEED PUMP TURBINE RUPTURE DISC (3MS-X1SAB-1)

TABULATION OF MAIN STEAM DRIP LEG PIPING (B19)(G18)

M D.C.

S B B

S S

FLOW LIMITER WITHIN NOZZLE AF SYS CAR 2165-G- 044 (N10) 2X3/4 RED. INS (TYP) 6" MIN.

(TYP) 2X1/2 RED. INS (TYP)

BY INST.

BY INST.

V V

VALVES SUPPLIED BY INST(TYP)

CAR-2165-G-044 (B2)

V 2X1/2 RED. INS VALVES SUPPLIED BY INST.

2X1 RED. INS.

RED. INS.

2X1 BY INST.

SUPPLIED VALVES 2X1/2 RED. INS V

(B2)

G-044 CAR-2165-BY INST(TYP)

VALVES SUPPLIED V

V BY INST.

(TYP) 6" MIN.

(TYP) 2X3/4 RED. INS BY INST.

2X1/2 RED. INS BY INST(TYP)

VALVES SUPPLIED V

V BY INST.

(TYP) 6" MIN.

(TYP) 2X3/4 RED. INS BY INST.

2X1/2 RED. INS (TYP)

V 2X1/2 RED. INS VALVES SUPPLIED BY INST.

2X1 RED. INS.

(B2)

S-044 CAR-2165-VENT TO ATMOS VENT TO ATMOS VENT TO ATMOS G

L.O.

SEE NOTE 1

& NOTE 2 DRAIN TO ROOF (TYP. OF 3)

FIXED RESISTOR 1A-NNS (FIXED RESISTOR JACKET)(TYP)

FD 5MS-U5-1 (TYP. OF 3)

HYDRO CONN A

F.C.

A MSIS F.C.

V SEE DETAIL 1 (D19)

(G18)

DETAIL 2 SEE F.C.

SAB MSIS MSIS SAB F.C.

SEE DETAIL 2 (G18)

(D19)

DETAIL 1 SEE F.C.

MSIS B

F.C.

B CONN HYDRO 1B-NNS RESISTOR FIXED

& NOTE 2 SEE NOTE 1 L.O.

G MSIS SAB F.C.

SEE DETAIL 2 (G18)

(D19)

DETAIL 1 SEE F.C.

MSIS A

F.C.

A CONN HYDRO 1C-NNS RESISTOR FIXED

& NOTE 2 SEE NOTE 1 L.O.

G D.C.

M SEISMIC CAT. 1 (TYP)

SEISMIC CAT. 1 (TYP)

V (TYP)

(TYP) 1H-NNS G

L.O.

F.C.

G L.O.

F.C.

NNS 1G-G L.O.

F.C.

NNS 1F-G L.O.

L.O.

G G

L.O.

F.C.

F.C.

F.C.

NNS 1D-1C-NNS 1B-NNS G

F.C.

NNS 1A-NNS 1E-G L.O.

F.C.

MAIN STEAM DUMP VALVE SILENCERS DUMP VALVE SILENCERS MAIN STEAM DRAIN TO ROOF (TYP. OF 8)

V M

F.C.

4" FD M

FD M

5MS-U3-1 F.C.

FD FD LEAKOFF DRAIN TO CONDENSER CONN. NO. 176 (K13)

MOISTURE SEPARATOR REHEATER 1A-NNS FD FD F.C.

5MS-U4-1 M

FD M

FD 4"

F.C.

M V

1B-NNS REHEATER (K13)

CONN. NO. 177 LEAKOFF DRAIN TO CONDENSER VENT(TYP)

VA. BY I&C (TYP) 5MS-V11-1 (TYP)

BY I&C (TYP)

BY MECH (TYP) 2X* RED (TYP)

NON SEISMIC SEISMIC CAT. 1 L.O.

(TYP)

(TYP)

F.C.

30 A

B C

D E

F G

H I

J K

L M

N 19 18 17 16 15 14 13 12 11 10 9

8 7

6 5

4 3

2 1

A B

C D

E F

G H

I J

K L

M N

19 18 17 16 15 14 13 12 11 10 9

8 7

6 5

4 3

2 1

NONE HARRIS NUCLEAR PROJECT - UNIT 1 CAR-2165 MAIN STEAM SYSTEM FLOW DIAGRAM CONTROL OF THE ELECTRONIC DRAWING DATABASE.

REVISIONS TO THIS DOCUMENT SHOULD BE DONE USING THE CAD/E SYSTEM TO ASSURE PROPER THIS DRAWING HAS BEEN PRODUCED AND IS CONTROLLED ON THE NED CAD/E SYSTEM. ANY NUCLEAR SAFETY RELATED (Q-LIST)

YES NO PARTIAL F.P.-Q R.W.-Q PLANT:

SCALE:

DWG NO.

CAROLINA POWER & LIGHT COMPANY NUCLEAR ENGINEERING DEPARTMENT - RALEIGH, N.C.

TITLE:

DPPE DESCRIPTION DATE REV G-042 UNIT 1 DWN CHK CAR-2165 G-042 F.C.

F.C.

29 26 25 F.C.

F.C.

CONDENSER 1X-NNS STM CHEST T

G T

G G

T G

T CHEST STM (M10)

CAR-2165-G- 189 TO AUX. STM. SYS.

(TYP)

(TYP) 5MS-V11-1 2X1 RED (TYP)

(TYP)

VA. BY I&C VENT (TYP)

(TYP)

(J18)

CAR-2165-G-189 AUX STEAM SUPPLY V

5AS-V42-1 FD 5MS-V11-1 L.O.

SEE DET. 2 (G18)

FD FD FD SEE DETAIL 2 (G18)

HIGH PRESSURE TURBINE IIIW IV W

LS V

FD FD FD F.C.

F.O.

5MS-V12-1 (TYP)

(TYP) 5MS-S1-1 (TYP) 5MS-U1-1 (TYP)

(TYP)

THIS DWG.

(G18) 5MS-V12-1 (TYP)

DETAIL-1 FOR SOURCE SEE TABULATION OF MAIN STEAM PIPING DRAIN (L10)

FD LINE CAT 5 FOR SOURCE DETAIL-2 (TYP)

(TYP) 5MS-S1-1 (TYP)

(TYP) 5MS-V12-1 F.O.

V LS (L10)

STEAM PIPING DRAIN (J17) OR (F13)

TO MAIN STEAM DR.

SEE TABULATION OF MAIN (TYP) 5MS-V12-1 (TYP) 5MS-U1-1 FD 5MS-V186-1 (TYP) 5MS-V11-1 (TYP) 5MS-V186-1 (TYP)

CONT THIS DWG (C18)

SEE DET. 2 (G18)

(TYP.)

NOTES:

1. ELECTRO-HYDRAULIC OPERATOR
2. LOCALLY MOUNTED MANUAL HYDRAULIC OPERATORS FOR USE DURING LOSS OF POWER.

42 FROM G.S. SUPPLY VALVE HDR DR DWG 1364-840 (B2) 86 23 28 83 CONN. #27 TRANSFERRED 150 84 149 148 147 39 DWG 1364-840 HP TURB DR (A3) 24 F.C.

STM. INLET DR DWG 1364-840 (A2) 38 1*"(TYP) 5MS-F6-1 FCV 0401 B2 STM. INLET DR DWG 1364-840 (A3) 5MS-F5-1 38 STM. INLET DR DWG 1364-840 (A3) 38 FCV 0401 A1 5MS-F4-1 1010 FCV STM. INLET DR DWG 1364-840 (A2) 38 5MS-F9-1 0401 FCV A2 5MS-F10-1 FROM HP TURB VENT VALVES 1364-840 (A1) 56 55 FROM HP TURB VENT VALVES 1364-840 (A1) 5MS-F7-1 B

0415 FCV 0415 FCV A

5MS-F8-1 W

CONN NO.

159 158 FCV 0401 B1 61 (G18)

DET. 2 SEE 19 TO GLAND SEAL SUPPLY HDR 1364-840 (B1)

M M

5MS-V152-1 5MS-V151-1 FOR DETAILS OF GLAND STEAM PIPING SEE DWG 1364-840 W

CONN. NO. (TYP)

W 52 51 FD FD 82 177 81 176 85 CONT. FROM (C10)

BLD. FLG.

(TYP. OF 3)

AE - STM GEN WET LAYUP PIPE CAR-2165-G-045 (H18)

(TYP. OF 3)

N - STM GEN WET LAYUP PIPE CAR-2165-G-089 (G13) 2 (TYP. OF 3)

CC BB DR RAB TURB.

BLDG.

AA 5MS-V11-1 (TYP. OF 6)

BLD. FLG. FOR F.D. &

STM. GEN WET LAYUP (TYP. OF 3)

SEE DETAIL 1 (D18) (TYP)

SEE DETAIL 2(G18)

FLOW LIMITER WITHIN NOZZLE FLOW LIMITER WITHIN NOZZLE 5MS-V11-1 VENT FD DRAIN 5MS-V11-1 PRESSURE CONNS TYPICAL 1" LINE & VALVE NOS.

OF VENTS, DRAIN & INSTR.

FOR CATEGORY 5 PIPING.

REFERENCE DRAWINGS PIPING LINE LIST VALVE & SPECIALITY LIST INSTRUMENT LIST FLOW DIAGRAM LEGEND CAR-1364-B-070 CAR-1364-B-069 CAR-2166-B-432 CAR-2165-G-041 VALVE NO VALVE NO LINE NO VALVE NO VALVE NO 5MS24-15-1 SOURCE LINE NO 2MS-V 189SA-1 2MS-V 191SB-1 2MS-V 193SA-1 2MS-V 190SA-1 2MS-V 192SB-1 2MS-V 194SA-1 2MS1/2-259SA-1 2MS1/2-260SB-1 2MS1/2-261SA-1 V173SA-1 2MS-V171SB-1 2MS-V 169SA-1 2MS-V 168SA-1 2MS-V170SB-1 V172SA-1 2MS1-246SA-1 2MS1-247SB-1 248SA-1 2MS-V 101SA-1 2MS-V102SB-1 V103SA-1 3MS-V105SAB-1 2MS-V 134SA-1 2MS-V135SB-1 V136SA-1 2MS-V 129SA-1 2MS-V130SB-1 V131SA-1 5MS24-14-1 3MS6-223SAB-1 2MS34-235SA-1 2MS34-236SB-1 237SA-1 3MS6-223SAB-1 5MS32-4-1 5MS32-3-1 5MS32-6-1 5MS44-8-1 5MS44-9-1 2MS-2MS-2MS1-2MS-2MS-2MS-2MS34-5MS12-168-1 5MS12-167-1 3MS6-166SAB-1 2MS12-122SA-1 2MS12-123SB-1 2MS12-124SA-1 3MS6-130SAB-1 5MS12-125-1 5MS12-126-1 5MS12-127-1 5MS12-128-1 5MS12-129-1 2

2 2

2 2

3 1

1 1

2 2

3MS2-169SAB-1 2MS2-131SA-1 2MS2-132SB-1 2MS2-133SA-1 3MS2-134SAB-1 3MS2-212SAB-1 2MS2-140SA-1 2MS2-141SB-1 2MS2-142SA-1 3MS2-143SAB-1 5MS2-215-1 5MS2-214-1 5MS2-5MS2-5MS2-146-1 144-1 145-1 5MS2-148-1 5MS2-149-1 5MS2-150-1 5MS2-151-1 5MS2-152-1 3MS-V58SAB-1 2MS-V93SA-1 2MS-V55SB-1 2MS-V56SA-1 3MS-V57SAB-1 2MS-V59SAB-1 2MS-V60SAB-1 2MS-V61SAB-1 2MS1-159SA-1 2MS1-160SB-1 2MS1-161SA-1 LS 0411A LS 0411B LS 0309A-S LS 0309B-S LS 0309C-S LS 0310A LS 0310B LS 0310C LS 0410A LS 0410B 5MS-V139-1 5MS-V140-1 5MS-V142-1 5MS-V143-1 5MS-V144-1 5MS-V146-1 5MS-V147-1 5MS-V148-1 5MS-V149-1 5MS-V150-1 LCV 0411A LCV 0411B LCV 0309A LCV 0309B LCV 0309C LCV 0310A LCV 0310B LCV 0310C LCV 0410A LCV 0410B 5MS-L1-1 5MS-L2-1 5MS-L4-1 5MS-L5-1 5MS-L6-1 5MS-L8-1 5MS-L9-1 5MS-L10-1 5MS-L11-1 5MS-L12-1 2MS1-154SA-1 2MS1-155SB-1 2MS1-156SA-1 V62SA-1 2MS-V63SB-1 2MS-V64SA-1 2MS-V70SA-1 2MS-V71SB-1 2MS-V72SA-1 DRIP LEG LINE NO LINE NO LINE NO LINE NO DETAIL LINE NO VALVE NO VALVE NO VALVE NO VALVE NO VALVE NO LINE NO LEVEL SWITCH NO VALVE NO VALVE NO LCV LCV VALVE NO LINE NO VALVE NO 2MS-VALVE NO VALVE NO LINE NO VALVE NO LINE NO VALVE NO TRAP NO 5MS-V208-1 5MS-V209-1 5MS-V210-1 5MS2-266-1 5MS2-265-1 5MS2-264-1 5MS-V199-1 5MS-V200-1 5MS-V201-1 BY INST BY INST BY INST 5MS-U2-1 W CONN. NO. (TYP)

L.O.

L.O.

5MS-V13-1 (TYP) f" f"

2X1 RED (TYP) 2 (A12)

CONT. FROM (TYP. OF 3)

(TYP) 2X* RED (TYP)

BY MECH (TYP)

BY I& C (TYP)

F.O.

V ARM G-089S02 (B4) 1X-NNS CPL-2165-SAMPLE COND. RACK TO SEC. SAMPLING TO SEC. SAMPLING SAMPLE COND. RACK 1X-NNS CPL-2165-G- 089S02 (B5)

TO SEC. SAMPLING SAMPLE COND. RACK 1X-NNS CPL-2165-G- 089S02 (B4)

TUBING (TYP)

I 5MS2-146-1 K

5MS2-150- 1 PT 1010 5MS-V251-1 5MS1-220-1 5AS6 1 5AS6 1 TE 0400 TE 0400 TE 0400 TE 0400 TE 0400 TE 0400 TE 0400 5MS-P5-1 5MS-P8-1 5MS-P4-1 5MS-P4-1 5MS-P4-1 5MS44 1 5MS44 1 5MS44 1 5MS44 1 TCV 0420 A

TCV 0420 A

TCV 0420 A

TCV 0420 A

TCV 0420 A

B 5MS-V165-1 5MS2-240-1 5MS-V114-1 5MS-P10-1 5MS32 1 5MS32-5-1 5MS10- 113-1 3MS-V99SA-1 3MS-V99SA-1 3

5MS1-255-1 3MS6-166SAB-1 5MS10 1 5MS10 1 5MS10 1 5MS10 1 5MS10 1 I

PT 1010 PT 1010 PT 1010 PX TE 0400 TE 0400 TE 0400 FT 0420 A

TCV 0420 A1 5MS-V94-1 2MS8-107SA-1 2MS8-107SA-1 2MS8-107SA-1 2MS8-107SA-1 2MS8-107SA-1 2MS8-107SA-1 2MS-V20SA-1 2MS-V28SB-1 2MS32-2SB-1 5MS2-150- 1 PT 1010 TE 0400 TE 0400 2

5MS1-255-1 3MS-V240SAB-1 5MS1-220- 1 3MS-V240SAB-1 3MS-V240SAB-1 5MS-V25-1 5MS-V26-1 6MS-V262-1 5MS-V245-1 5MS-V244-1 5MS-V232-1 5MS-V231-1 5MS-V229-1 5MS-V228-1 5MS-V230-1 5MS-V227-1 5MS-V83-1 5MS-V180-1 5MS-V95-1 5MS-V181-1 5MS-V97-1 5MS-V96-1 5MS-V185-1 5MS-V184-1 2MS-V159SA-1 2MS-V160SA-1 2MS-V3SAB-1 2MS-V157SB-1 2MS-V158SB-1 2MS-V2SAB-1 2MS-V1SAB-1 2MS-V156SA-1 2MS-V155SA-1 2MS-V19SA-1 2MS-V15SA-1 2MS-V16SA-1 2MS-V27SB-1 2MS-V28SB-1 2MS-V23SB-1 2MS-V24SB-1 2MS-V85SA-1 2MS-V84SA-1 2MS-V89SA-1 2MS-V88SA-1 3MS-V234SAB-1 3MS-V167SAB-1 3MS-V53SAB-1 3MS-V54SAB-1 3MS-V98SAB-1 3MS-V235SAB-1 3MS-V92SAB-1 3MS-V233SAB-1 2MS-V37SA-1 2MS-V36SA-1 2MS-V42SA-1 2MS-V43SA-1 2MS-V49SA-1 2MS-V48SA-1 2MS-V35SB-1 2MS-V34SB-1 2MS-V40SB-1 2MS-V41SB-1 2MS-V47SB-1 2MS-V46SB-1 2MS-V44SA-1 2MS-V45SA-1 2MS-V39SA-1 2MS-V38SA-1 2MS-V32SA-1 2MS-V33SA-1 5MS-V11-1 3MS-V241SAB-1 3MS-V240SAB-1 PX PS PT PI PX PS 0420 PCV 1842 PT 1004 PCV 0408 C

LCV LCV PX PT 1000 PS 1006 PS 1005 PT 0447 PX PT 0446 PT 1010 TW 0400 A

PI 0401 PT 0464 PX PX FX FT 0420 B

FE 0420 B

PT 0400 PX TW 0400 B

TE 0400 PCV 0408 H

PCV 0408 F

PCV 0408 G

PCV 0408 A

PCV 0408 B

FE 0420 A

TCV 0420 B

TCV 0420 A

FT 0420 A

TCV 0420 B1 PI 0420 B

PT 0420 PX 0421 B

PX PT 0420 A

PI 0420 A

TCV 0420 A1 PCV 0408 N

PCV 0408 Q

PCV 0408 R

PCV 0408 L

PCV 0408 M

PCV 0408 P

PCV 0408 J

PCV 0408 K

PCV 0308 C

S PT 0308 C

S FCV 0313 PCV 0308 B

S PT 0308 B

S FCV 0312 FCV 0311 PT 0308 A

S PCV 0308 A

S PI 0431 PT 0430 PDT 2180 PS 0431 PI 0430 A

6MS-V260-1 5MS-V166-1 5MS-V114-1 5MS-V116-1 5MS-V117-1 5MS-V112-1 5MS-V113-1 5MS-V115-1 5MS-V110-1 5MS-V111-1 2MS-V163SA-1 2MS-V162SB-1 2MS-V161SA-1 3MS-V14SAB-1 PX LT 9951 S

LT 9952 S

LT 9953 S

PT 0494 W

PX 0494 PT 0495 W

PT 0496 W

PT 0484 W

PX 0484 PT 0485 W

PT 0486 W

PT 0476 W

PT 0475 W

PX 0474 PT 0474 W

TE 0430 S

5MS2-303-1 5MS14-182-1 5MS1-220-1 2MS12-124SA-1 2MS12-123SB-1 2MS12-122SA-1 2MS32-1SA-1 5MS1-220- 1 5MS1-220- 1 5MS12-167-1 6MS8-206-1 5MS2-144-1 5MS2-145-1 5MS2-146-1 5MS1-220-1 5MS14-181-1 6MS6-233-1 6MS1-216-1 6MS1-216-1 6MS4-234-1 5MS12-128-1 5MS24-13-1 5MS24-11-1 5MS24 1 5MS3/4-294-1 5MS24-10-1 5MS12-129-1 6MS12-307-1 5MS2-227-1 5MS2-228-1 5MS2-209-1 5MS2-211-1 5MS2-210- 1 5MS2-208-1 5MS2-207-1 5MS8-26-1 5MS12-43-1 5MS8-25-1 5MS12-42-1 6MS1-190-1 5MS12-183-1 5MS2-214-1 5MS2-152-1 5MS2-151-1 5MS12-45-1 5MS8-28-1 5MS12-168-1 5MS2-222-1 5MS1-220-1 5MS1-297-1 5MS2-215-1 5MS2-148-1 5MS2-149-1 5MS2-150- 1 5MS1-220-1 5AS6 1 5MS44-8-1 5MS24-14-1 5MS24-16-1 5MS24-15-1 5MS4-189-1 5MS12-17-1 5AS4 1 5AS1-36-1 5MS1-220- 1 5MS12-39-1 5MS8-22-1 5MS12-40-1 5MS8-23-1 5MS16-217-1 5MS12-41-1 5MS8-24-1 5MS44 1 5MS1-220- 1 5MS6-252-1 5MS1-220-1 5MS1-251-1 5MS6-254-1 5MS1-220-1 5MS11/2 1 5MS1-253-1 5MS12-18-1 5MS2-240-1 5MS12-50-1 5MS8 1 5MS12 1 5MS12 1 5MS12 1 5MS12 1 5MS8-32-1 5MS8-36-1 5MS8-37-1 5MS12 1 5MS12 1 5MS8 1 5MS8-29-1 5MS8 1 5MS12 1 5MS2-222-1 2MS6-56SB-1 3MS6-59SB-1 2MS1-226SA-1 2MS6-57SA-1 2MS8-109SA-1 6MS48-243-1 5MS1-218-1 5MS10-115-1 2MS1-300SA-1 5MS32 1 5MS50 1 5MS12-127-1 2MS3-118SA-1 5MS3-121-1 2MS1-225SB-1 2MS8-108SB-1 6MS48-242-1 5MS1-218-1 5MS10-114-1 2MS1-299SB-1 5MS32-5-1 5MS50 1 5MS12-126-1 2MS3-117SB-1 5MS3-120-1 5MS3-119-1 2MS3-116SA-1 5MS12-125-1 5MS8-33-1 5MS32-4-1 2MS1-224SA-1 2MS34-235SA-1 2MS1-298SA-1 5MS10- 113-1 5MS1-218-1 6MS48-241-1 2MS8-107SA-1 2MS1-172SA-1 2MS1-267SA-1 2MS2-186SA-1 2MS32-2SB-1 2MS2-187SB-1 2MS1-268SB-1 2MS2-188SA-1 2MS1-269SA-1 2MS32-3SA-1 3MS1-244SAB-1 3MS1-203SAB-1 3MS1-204SAB-1 3MS6-130SAB-1 3MS6-60SA-1 3MS16-185SAB-1 3MS16-238SAB-1 5MS1-255-1 3MS8-230SAB-1 3MS1-286SAB-1 6MS1-287-1 3MS6-223SAB-1 3MS6-166SAB-1 2MS8-76SA-1 2MS8-73SA-1 2MS8-75SA-1 2MS8-72SA-1 2MS8-74SA-1 2MS34-237SA-1 2MS34-236SB-1 6MS3/4-221-1 2MS8-71SB-1 2MS8-69SB-1 2MS8-67SB-1 2MS8-70SB-1 5MS10 1 5MS10 1 6MS16-102-1 5MS10 1 5MS10 1 5MS10 1 6MS16-103-1 6MS16-104-1 6MS16-105-1 6MS16-106-1 2MS1-112SA-1 2MS1-177SA-1 2MS1-174SA-1 2MS1-180SA-1 2MS8-68SB-1 5MS10 1 5MS10 1 6MS16 1 5MS10 1 5MS10 1 5MS10 1 6MS16 1 6MS16 1 6MS16-100- 1 6MS16-101-1 2MS1-111SB-1 2MS1-176SB-1 2MS1-173SB-1 2MS1-179SB-1 2MS1-178SA-1 2MS1-175SA-1 2MS1-110SA-1 5MS1-220-1 6MS1-216-1 6MS1-216-1 2MS8-66SA-1 2MS8-65SA-1 6MS16 1 6MS16 1 6MS16 1 6MS16 1 5MS10 1 5MS10 1 5MS10 1 6MS16 1 2MS8-63SA-1 2MS8-64SA-1 5MS10 1 2MS8-62SA-1 5MS10 1 3MS1-296SAB-1 2MS-P18SA-1 2MS-R3SA-1 2MS-R6SA-1 2MS-R9SA-1 2MS-R12SA-1 2MS-R15SA-1 2MS-R2SB-1 2MS-R5SB-1 2MS-R8SB-1 2MS-R11SB-1 2MS-R14SB-1 2MS-R13SA-1 2MS-R10SA-1 2MS-R7SA-1 2MS-R4SA-1 2MS-R1SA-1 5MS-P6-1 5MS-P2-1 5MS-P3-1 5MS-P4-1 5MS-P13-1 5MS-P15-1 5MS-P17-1 5MS-P12-1 5MS-P16-1 5MS-P14-1 5MS-P9-1 2MS-F3SAB-1 2MS-F2SAB-1 2MS-F1SAB-1 2MS-V126SAB-1 2MS-V124SAB-1 2MS-V122SAB-1 E

2MS-V74SA-1 3

3 3

3 2

2 3

2 2

2 2

2 2

2 2

2 3

3 3

3 5MS-V164-1 3MS-V100SB-1 3MS-V99SA-1 2MS-V8SA-1 2MS-V9SB-1 5MS-V239-1 5MS-V238-1 5MS-V250- 1 5MS-V179-1 5MS-V178-1 5MS-V183-1 5MS-V182-1 5MS-V13-1 2MS-P20SA-1 2MS-P19SB-1 2MS-V77SA-1 2MS-V202SA-1 2MS-V203SA-1 2MS-V75SB-1 2MS-V78SB-1 2MS-V205SB-1 2MS-V204SB-1 2MS-V79SA-1 2MS-V207SA-1 2MS-V206SA-1 2MS-V76SA-1 5MS-M3-1 5MS-M2-1 5MS-M1-1 5MS-M4-1 K

FF EE DD CC BB AA Q

O N

M L

K J

H G

F E

D C

B A

S T

W X

Y Z

R P

I L

K E

J K

M B

A E

K L

M K

DD FF EE G

N J

W F

C Z

Y X

T Q

O S

D B

H A

R P

I PX PX PX B

A FD C

F W

D T

EE FF BB CC AA FD LINE CAT 3 FOR SOURCE DETAIL-3 STEAM PIPING DRAIN SEE TABULATION OF MAIN DD MSIS LINE CAT 2 (D13)

TO DWG. G-045 3MS-V 104SB-1 3

U7SAB-1 3MS-U8SAB-1 3MS-

-1 308SAB 3MSf-

-1 309SAB 3MSf-

-1 V263SAB 3MS-

-1 301SAB 3MSf-

-1 V264SAB 3MS-

-1 302SAB 3MSf-

-1 V252SAB 3MS-

-1 V253SAB 3MS-

-1 T4SAB 3MS-

-1 T5SAB 3MS-(J18)

DETAIL 3 SEE (J18)

(L10) 5MS1*-153-1 5MS1*-153-1 5MS1*-153-1 5MS1*-153-1 5MS*-257-1 5MS*-257-1 5MS*-276-1 5MSf - 289-1 5MSf-290-1 5MSf-291-1 5MSf-295-1 5MSf - 293-1 5MS1*-19-1 5MS*-276-1 6MSf-221-1 6MSf-221-1 6MS1*-288-1 5MSf-285-1 3MSf-282SAB-1 3MSf-283SAB-1 5MSf - 284-1 2MS* - 275SA-1 2MS*-274SA-1 2MSf-201SA-1 2MSf-199SA-1 2MS* - 279SA-1 2MS*-272SB-1 2MSf-197SB-1 2MSf-195SB-1 2MS* - 273SB-1 2MS* - 278SB-1 2MS* - 277SA-1 2MS*-270SA-1 2MSf-193SA-1 2MSf-191SA-1 2MS* - 271SA-1 6MSf-221-1 34 (D2,H2,K2)

INCORPORATED: ESR 95-00153 RPP DLS 12/30/99 35 ARM 62 M

PCV 1841 50 FD M

F.C.

6MS-V154-1 6MS-V153-1 6MS-V197-1 6MS-V198-1 6MS-V261-1 6MS1-216-1 6MS-V265-1 1364-840 TURBINE GLANDS TO/FROM HP 1364-840 FROM PCV-1843 1364-840 VALVE ASSEMBLY FROM STOP/CONTROL 6MS6-229-1 6MS1-263-1 ORIFICE BLOCK 1/4"Ú (BY FIELD) 6MS-U6-1 6MS6-232-1 W CONN. NO.

(TYP) 6MS5-312-1 6MS10-304-1 6MS1-305-1 6MS6-306-1 6MS8-310-1 6MS6-311-1 (G11,G12,H10-H12,I10-,I12)

INCORPORATED: ESR 00-00264 HDR. TO CONDENSER TO MAIN STEAM DR.

HDR. TO CONDENSER (I10)

(TYP) 3MS6-223SAB-1 9

(A1) 5-G- 044 FROM FT- 0475 (A1) 5-G- 044 FROM FT- 0474 (F1) 5-G- 044 FROM FT- 0485 (F1) 5-G- 044 FROM FT- 0484 (K1) 5-G- 044 FROM FT- 0495 (K1) 5-G- 044 FROM FT- 0494 9/23/01 JWB DLS 36 SIGNED ELECTRONICALLY INCORPORATED: EC# 61953 (B12) 5MSf-292-1 5MSf-280-1 5MSf-281-1 SIGNED ELECTRONICALLY 37 (A17,B10,B14,E13-E16)

INCORPORATED: EC# 74907 SIGNED ELECTRONICALLY 38 TE MOISTURE SEPARATOR PT TE A

0624 A

0410 B

0624 5MS-V267-1 5MS-V266-1 TW 0624 B

5MSf-313-1 PT B

0410 5MS-V269-1 5MS-V268-1 5MSf-314-1 TW 0624 A

(A10,A15)

INCORPORATED: EC# 284723, 279938

DRIP PAN DRAIN SEE DETAIL 3 6ES-R2-1 SEE DETAIL 3 SEE DETAIL 2 SEE DETAIL 2 SEE DETAIL 2 SEE DETAIL 2 6ES-C3-1 6ES-C1-1 6ES-C2-1 6ES-C4-1 100 25 24 99 101 22 42 102 98 44 103 48 13 97 12 96 104 10 55 105 95 57 61 106 6ES-V7-1 6ES-V20-1 (TYP OF 8)

(TYP) 6ES-V8-1 6ES-V10-1 (TYP)

CHEM.

CLEAN CONN.

6ES-R3-1 6ES-R4-1 6ES-V6-1 HEATING STEAM CONN.

6ES-R5-1 6ES-V3-1 6CE-V195-1 6ES-R6-1 6CE-V196-1 6ES-V4-1 FW PUMPS SEAL 6ES-R7-1 SEE DETAIL 2 14" 6ES-R8-1 CHEM.

CLEAN CONN.

14" 6ES-V2-1 SEE DETAIL 2 AUXILIARY STEAM SYSTEM 5-G-189 (H17)

SAMPLING ASSEMBLY CAR-2165-G-089 (A14)

BY MECH BY I&C 6ES-V40-1 1 X RED.

6ES-V47-1 6ES-V48-1 6ES-V42-1 BY I&C BY MECH (A14)

CAR-2165-G-089 SAMPLING ASSEMBLY 6ES-R12-1 6ES-R11-1 6ES-R9-1 6ES-R10-1 26" 26" 22" 24" 24" 22" 26" 26" 26" 26" 22" 24" 24" 22" 26" 26" 6ES-V11-1 (TYP)

(TYP)

DISSOLVED OXYGEN VENT 2165-G-045 TO SAMPLING ASSEMBLY CAR-2165-G-089 VACUUM TRIP TO LOW SEE DET.3 SEE DET.1 SEE DET.2 SEE DET.1 SEE DET.2 SEE DET.1 6ES-F4-1 6ES-F1-1 6ES-F2-1 6ES-F3-1 STG STG 11 8

7 12 SEE DET.1 SEE DET.1 6ES-C5-1 6ES-C9-1 NOTE 1 6ES-V49-1 6ES-V43-1 BY MECH.

BY I&C 156 107 155 115 106 16 2 REQ'D 2 REQ'D 18 95 120 EAST SIDE WEST SIDE 120 192 191 4 REQ'D 114 SIDE EAST 121 193 194 2 REQ'D 155 2 REQ'D 156 108 109 17 96 6ES-V45-1 6ES-V50-1 NOTE 1 6ES-V46-1 1" X "

RED.

TO SAMPLING SEE DETAIL 1 SEE DETAIL 1 6ES-C11-1 6ES-C7-1 INJECTION 6ES-V11-1(TYP)

(TYP)

BY MECH BY I&C 56 91 54 14 43 92 41 26 f"

f" f"

f" f"

f" f"

f" f"

f" f"

f" 1A-NNS L.P.HEATER 2 L.P.HEATER 2 1B-NNS L.P.HEATER 3 1A-NNS L.P.HEATER 3 1B-NNS L.P.HEATER 4 1A-NNS L.P.HEATER 4 1B-NNS H.P.HEATER 5 1A-NNS 1B-NNS H.P.HEATER 5 HIGH PRESSURE TURBINE L.P.TURBINE B L.P.HEATER 1 1B-NNS 1A-NNS L.P.HEATER 1 VALVES & TUBING BY I&C VALVES & TUBING BY I&C HOTWELL FD 6ES-V5-1 6ES-V1-1 FD FD REHEAT INTERCEPT VALVE (TYP)

REHEAT STOP VALVE (TYP)

RED.

1 X PIPING LINE LIST VALVE & SPECIALTY LIST INSTRUMENT LIST FLOW DIAGRAM LEGEND CAR-1364-B-070 CAR-1364-B-069 CAR-2166-B-432 CAR-2165-G-041 DENOTES VENDORS CONN. ON CONDENSER DENOTES VENDORS CONN. ON TURBINE

1. ISOKINETIC SAMPLING NOZZLE LOCATION (DUAL-NOZZLE MULTI.-PORT TYPE)

A B

C D

E F

G H

I J

K L

M N

19 18 17 16 15 14 13 12 11 10 9

8 7

6 5

4 3

2 1

A B

C D

E F

G H

I J

K L

M N

19 18 17 16 15 14 13 12 11 10 9

8 7

6 5

4 3

2 1

NONE HARRIS NUCLEAR PROJECT - UNIT 1 EXTRACTION STEAM SYSTEM NUCLEAR SAFETY RELATED (Q-LIST)

YES NO PARTIAL F.P.-Q R.W.-Q PLANT:

SCALE:

DWG NO.

TITLE:

DESCRIPTION REV DWN CHK 58 57 59 60 ZONE 1 ZONE 2 TO ATM (TYP)

CHEM.

CLEAN CONN.

L.P.TURBINE A FLOW DIAGRAM 45 44 44 45 44 45 44 45 F.O.

F.O.

F.O.

F.O.

15 CAR-2165 CAR-2165 G-043 STG STG (A15)

BY I& C BY MECH.

76 REFERENCE DRAWINGS LEGEND 56 146 145 144 CONDENSER FD 1X-NNS M

M M

M M

M M

M M

M 4 REQ'D (TYP)

NOTE:

(H14)

(A15)

(DETERMINATED)

(DETERMINATED) 6ES1-96-1 6ES1-103-1 6ES3/4-110- 1 6ES1 1 6ES1-85-1 6ES1-71-1 6ES3/4-112-1 6ES3/4-113-1 6ES1-104-1 6ES3/4-111-1 6ES1-71-1 6ES1-98-1 6ES36-8-1 6ES26-6-1 6ES2-9-1 6ES2-10-1 6ES2-11-1 6ES2-12-1 6ES1-85-1 6ES1-71-1 6ES24-55-1 6ES24-56-1 6ES24-58-1 6ES24-57-1 6ES1-102-1 6ES3/4-108-1 6ES3/4-109-1 6ES3/4-107-1 6ES3/4-106-1 6ES1-101-1 6ES24-24-1 6ES3/4-84-1 6ES2 1 6ES2 1 6ES2 1 6ES36 1 6ES2 1 6ES26 1 6ES2 1 6ES2 1 6ES2 1 6ES2 1 6ES2 1 6ES2 1 6ES2 1 6ES2 1 6ES14 1 6ES14-43-1 6ES14-45-1 6ES14 1 6ES2 1 6ES2 1 6ES2 1 6ES2 1 6ES2 1 6ES2 1 6ES2 1 6ES2 1 6ES2 1 6ES36 1 6ES2 1 6ES2 1 6ES2 1 6ES26 1 6AS10-3-1 6ES1 1 6ES1-15-1 6ES1 1 6ES1 1 6ES10-69-1 6ES10-68-1 6ES10-82-1 6ES20-4-1 6ES12-2-1 6ES20-3-1 6ES12-1-1 6ES2-22-1 6ES2-19-1 6ES6-46-1 6ES10-83-1 6ES6-47-1 6CE3-72-1 6ES6-49-1 6ES8-81-1 6CE3-218-1 6ES6-48-1 6ES8-80-1 6ES2-25-1 6ES2-28-1 6ES6-75-1 6ES2-34-1 6ES6-51-1 6ES10-74-1 6ES2-31-1 6ES8-78-1 6ES6-50-1 6ES8-79-1 6ES24-27-1 6ES2-40-1 6ES2-73-1 6ES24-18-1 6ES8-53-1 6ES10-77-1 6ES2-37-1 6ES2-73-1 6ES24-21-1 6ES8 1 6ES10-76-1 6ES1 1 6ES-R1-1 PX PT 0700 A

PX TE 1340 A

PT 1900 B

PS 1900 B

PX 1990 B1 PT 1540 B

PX 1990 B2 PX PS 1900 A

PT 1900 A

PX PT 0600 B

PX PT 0600 A

PX PT 1540 A

PX PX 1990 A2 PX 1990 A1 PT 0620 A

PI 0620 A1 PX 0702 A

PI 0620 A2 PX PT 0710 PX PT 0700 B

PX PI 0620 B1 TE 4174 RHI RHI TE 0700 A

PT 0720 TE 4169 TW 0700 A2 TW 0700 A1 TE 4170 PT 0620 B

PI 0620 B2 PS 4175 PX 0701 B

TE 4168 TW 0700 B1 TW 0700 B2 TE 4167 TE 0700 B

TE 4173 RHI RHI RHV RHV RHV RHV TW 0710 B4 TW 0710 B3 TW 0710 B1 PX PX B2 TW 0710 B2 PX PX TW 0710 A4 TW 0710 A3 PX PX 0710 A2 TW TW 0710 A1 PX PX PX PX FCV 0600 B2 FCV 0600 A2 FCV 0600 A1 FCV 0600 B1 PX 1140 B

PX 1140 A

PT 1140 B

PT 1140 A

PS 1240 B

PT 1240 A

PT 1240 B

PS 1240 A

PX 1240 A

PX 1240 B

TE 1340 B

PX 1340 B

PX 1340 A

PT 1340 A

PT 1340 B

PT 1440 B

PX 1440 B

PX 1440 A

PT 1440 A

1 X RED.

6ES-V44-1 NOZZLE(TYP) 1 * " X 1" RED.(TYP)

BLEED OFF CAR-2165-G-088 (G8)

(G8)

ASSEMBLY CAR-2165-G- 089 26" 26" APPROVED AND DATED ELECTRONICALLY SIGNED OPERATION (EC79388)

2. 6ES-V22-1 IS CLOSED (NOT LOCKED OPEN) DURING NORMAL 6ES1 1/2-116-1 PX 6ES1 1/2-117-1 6ES1 1/2-118-1 6ES1 1/2-119-1 PX 26 AND DATED ELECTRONICALLY SIGNED (H8-H9,G8,G9,G16-G18)

INCORPORATED: EC 81209 10TH 6TH 6TH 10TH PX 6ES1 1/2-114-1 CASING DRAIN FROM HPT OUTER 6ES1 1/2-115-1 FROM HPT OUTER CASING DRAIN TURBINE A L.P.

TURBINE B L.P.

(TYP. 16 PLCS)

BASKET TIP 16TH 16TH 15TH 13TH 13TH 15TH 16TH 16TH 16TH 16TH 15TH 13TH 13TH 15TH 16TH 16TH 27 E9-E15,H10-H15,I10-I15,J10-J15,K10-K14)

B11,B13,B14,C2-C4,D3,D4,D9,D10,D12-D14,E3, INCORPORATED: EC 74907 (B2-B4,B10, 28 INCORPORATED: EC 74907 REV. 25 (M7,N7) 29 AND DATED ELECTRONICALLY SIGNED A

0703 TW A

0703 TE A

0704 TE A

0704 TW A

0628 TX TX 0627 A

A 0640 PDT A

0625 TX A

0629 TX PT 0644 A

B 0640 PDT B

0627 TX B

0703 TW B

0703 TE B

0628 TX B

0704 TE B

0704 TW B

0629 TX B

0641 PDT PT 0644 B

A 0641 PDT MOISTURE SEPARATOR-REHEATER 1A-NNS FD NOTE 1 6ES-V39-1 1B-NNS MOISTURE SEPARATOR-REHEATER

3. SEE SHEET 1 FOR DETAILS ON SHEET 1 ON SHEET 1 ON SHEET 1 ON SHEET 1 ON SHEET 1 ON SHEET 1 ON SHEET 1 ON SHEET 1 ON SHEET 1 ON SHEET 1 ON SHEET 1 ON SHEET 1 SEE DET.1 ON SHEET 1 ON SHEET 1 ON SHEET 1 NOTE 1 6ES-V41-1 ON SHEET 1 ON SHEET 1 SEE DET.1 ON SHEET 1 SEE DET.1 ON SHEET 1 SEE DET.1 ON SHEET 1 SEE DET.1 ON SHEET 1 SEE DETAIL "A" ON SHEET 1 PDT/PT INTERNAL SEE DETAIL "A" ON SHEET 1 PDT/PT INTERNAL ON SHEET 1 ON SHEET 1 SEE DET.2 SEE DET.1 ON SHEET 1 ON SHEET 1 AND DATED ELECTRONICALLY SIGNED INCORPORATED: EC 74907 REV. 27 (E9,E12) 30 AND DATED ELECTRONICALLY SIGNED MOVED TYPICAL DETAILS TO 5-G-0043 S01 INCORPORATED: EC 284723 (B9-B15),

G-0043 DUKE ENERGY A

0626 TX B

0626 TX B

0625 TX A

624 TE A

624 TW B

624 TE B

624 TW

1 2

4 5

6 7

8 9

10 I2 15 14 15 16 1-7 18 I9 CAR-2165 G-044 S02

/

E c

c E

F G

H I

J A

E3 c

D E

F G

H I

J K

L M

N N 2 SUPPLY 6FW -V221-1 f-7 I

(, 6 F W I -

1 8 9 - I,)

6 F W I -

I 9 I - I I

>\\I 6 F W I -

19@-

I cs-I cs-1 cs-1 VENDOR NOTE 1 VENDOR NOTE 1 VENDOR NOTE 1 NOTES:

1. VENDOR SUPPLIED P I P I N G AND COMPONENTS MOUNTED ON ACCUMULATOR TANK PANEL.

CONN.

TEST cl-+k-i

CONN, TEST [~
CONN, TEST c~

M I v, v,

I1L Ol?

i I

2. FOR NOTES AND REFERENCE DRAWINGS SEE 5-G-044
3. WITH THE EXCEPTION OF THE ACCUMULATORS AND ASSOCIATED RELIEF VALVES, ALL COMPONENTS AND P I P I N G DOWNSTREAM OF THE INLET SIDE OF THE CHECK VALVES, INCLUDING THE CONTROL RELIEF VALVES ARE ASME 111, CLASS 2. REFERENCE EC 79837 AND PANELS, ARE SAFETY CLASS 2, NON-ASME.

THE ACCUMULATORS AND I v, v,

SEE NOTE 3@+--

- I 2 F W 2 - I 9 2SAB - I ro 2FW2-195SAB-1 5

CPL-HNPI-M-032 2FW2 - 1 9 8 S A B - 1

\\

t-4 T

i F

l

$ 2FW-V222SAB-1 1 2FW-V223SAB-1 f

ss-3 VENDOR ss-3 VENDOR T

VENDOR T

SEE NOTE 3 I

I SEE NOTE 3 SEE NOTE 3 I

I CONTROL PANEL CONTROL PANEL CONTROL PANEL i i VENDOR VENDOR VENDOR ss-3 2 FW2 - 2 0 0 S A B - 1 CAR-2 165-G-04 I

W I

(K6) 2FW-I 163SAB-1 ss-3 T T 2FW2-194SAB-1 CAR-2165-G-044 (56) 2FW-I159SAB-1 CAR-2165-G-044 2FW-I 1 64SAB-1 (K6)

CAR-2165-G-M44 (56) 2FW - I1 60SAB-1 K

ELECTRONICALLY SIGNED REVISED PER EC# 79837 (G17-GI9)

M 1

w ARM D LS 1

RPP 1

5/4/00 1 I N I T I A L ISSUE PER ESR 97-00233 1

REV DATE 1 DESCRIPTION 1

DWN 1

CHK 1

DPPE THIS DRAWING HAS BEEN PRODUCED AND I S CONTROLLED ON THE NED CAD/E SYSTEM. ANY REVISIONS TO THIS DOCUMENT SHOULD BE DONE USING THE CAD/E SYSTEM TO ASSURE PROPER CONTROL OF THE ELECTRONIC DRAWING DATABASE.

NUCLEAR SAFETY RELATED (Q-LIST)

YES-N O

I

i PARTIAL-F. P. - Q D R. W. 4 -

CAROLINA POWER 8c LIGHT COMPANY NUCLEAR ENGINEERING DEPARTMENT - RALEIGH, N.C.

NONE HARRIS NUCLEAR PROJECT - UNIT 1 I SCALE:

PLANT:

I DWG NO.

FLOW DIAGRAM FEEDWATER SYSTEMS UNIT 1 TITLE:

FEEDWATER 8c AUXILIARY CAR-21 65 G-044 S02 2

4 5

6 7

8 10 12 14 16 17 18 19

FOR CONT. SEE DET. A (TYP 6)(M9)

(NOTE 5)

(NOTE 5)

DETAIL E HEATER 4 1A-NNS & 1B-NNS VENT & DRAIN TRIM.

SEE DET. E FOR HEATER 4 1A-NNS & 1B-NNS CONT. (M13)

(TYP.)

6HD-V41-1 6HD-V43-1 (TYP.)

6HD-V41-1 (TYP.)

(TYP.)

6HD-V41-1 (TYP.)

6HD-V43-1 DRAIN VENT 10" 4"

FD (TYP.)

(TYP.)

FD (TYP.)

(TYP.)

(TYP.)

8" (TYP.)

1 '"(TYP.)

(TYP.)

(TYP.)

(TYP.)

(TYP.)

(TYP.)

DISCH. VENT HD PUMP 6"

(TYP.)

(TYP.)

(TYP.)

(TYP.)

A B

C 19 18 17 D

E F

G 16 15 14 13 12 11 10 H

I J

K L

M N

SCALE:

DWG NO.

NONE PLANT:

TITLE:

HARRIS NUCLEAR PROJECT - UNIT 1 CONTROL OF THE ELECTRONIC DRAWING DATABASE.

REVISIONS TO THIS DOCUMENT SHOULD BE DONE USING THE CAD/E SYSTEM TO ASSURE PROPER THIS DRAWING HAS BEEN PRODUCED AND IS CONTROLLED ON THE NED CAD/E SYSTEM. ANY NUCLEAR SAFETY RELATED (Q-LIST)

YES NO PARTIAL F.P.-Q R.W.-Q HEATER DRAIN & VENT SYSTEMS FLOW DIAGRAM 19 18 17 16 15 14 13 12 11 10 9

8 7

6 5

4 3

2 1

CAR-2165 G-046 A

B C

D E

F G

9 8

7 6

5 4

H I

J K

L 3

2 1

M N

14" 14" FD 14" 14" (TYP.)

(TYP.)

(TYP.)

(TYP.)

(TYP.)

(TYP.)

(A3)(TYP.)

SEE DET D 6HV-U9-1(TYP.)

6HV-U9-1(TYP.)

(A3)(TYP.)

SEE DET D FD 1B-NNS LP HEATER 3 FD EMERG DR CONN (CAPPED)

F.C.

LP HEATER 2 1B-NNS FD F.C.

6HV-U2-1(TYP)

FD 1B-NNS LP HEATER 1 CONDENSER WALL FD FD FD 1A-NNS FD LP HEATER 3 EMERG DR CONN (CAPPED)

FD FD FD FD (TYP.)

1X-NNS CONDENSER 6HV-U2-1 F.C.

1A-NNS FD 6HV-U2-1 F.C.

FD LP HEATER 1 1A-NNS FD LP HEATER 2 EMERG DR CONN (CAPPED)

EMERG DR CONN (CAPPED)

F.O.

FD FD F.O.

F.O.

FD F.O.

FD F.O.

F.O.

F.O.

F.O.

FD FD F.O.

F.O.

FD F.O.

FD WALL FD FD F.O.

8" FD F.O.

F.O.

6" F.O.

F.O.

FD F.O.

FD (TYP.)

(TYP.)

(TYP.)

(TYP.)

(TYP.)

6HV-V11-1 1 '"(TYP.)

8" SEE DET. D (A3)(TYP.)

(TYP.)

6HV-U5-1 (TYP.)

SEE DET A (N11) & TAB (M3)

FOR HEATER TRIM(TYPICAL FOR ALL HEATERS)

(TYP.)

(A3.)(TYP.)

SEE DET. D (TYP.)

6HV-U5-1 (TYP.)

3" 1 '"

(TYP.)

8" 10" 8"

FD LG-0650B1 (MS DRAIN TANK 1B)

LG-0650A1 (MS DRAIN TANK 1A) 6HD-V41-1 5HD-V39-1 OR 5HD-V39-1 5HD-V39-1 (TYP.)

(TYP.)

1"x3/4" REDS.

TYP. ALL EXCEPT FT-0650B (TYP.)

6HD-V41-1 (TYP.)

EQUIPMENT DETAIL B TYPICAL INSTRUMENT CONNECTION (UNLESS OTHERWISE NOTED)

ALSO SEE DETAIL"B1 & B2"(F19,G19,H19)

(USE FOR SYSTEMS 5 & 6 AS APPLICABLE) 6HD-V43-1 (TYP.)

5HD-V38-1 (MSRDT ONLY)

NOTE 3 NOTE 3 6HD-V43-1 (TYP.)

LT-0450A LT-0450B LT-1450A LT-1550A 6HD-V43-1 (TYP.)

5HD-V38-1 (TYP FOR MSRDT ONLY)

ADDITIONAL LS CONNECTIONS AS REQUIRED 5HD-V39-1 6HD-V41-1 (TYP.)

5HD-V38-1 (TYP. FOR MSRDT ONLY) 5 LINES & VALVES ONLY MSR(TUBE SIDE)DRN. TANK USE CATEGORY HEATER, MS & MSR. DRAIN TANK TRIM DETAIL A EQUIPMENT 1-1A 1-1B 2-1A 6HD-V43 12 12 12 VALVE QUANTITIES 12 2-1B 12 3-1A 12 3-1B 12 4-1A 12 4-1B 12 5-1A 12 5-1B 1A 1B 8

1A 8

1B DRAIN TANK MSR MS HEATERS 12 12 5HD-V38 14 14 20 20 28 28 20 20 20 20 20 20 6HD-V41 18 18 5HD-V39 LS-LS-LS-0650B 0650A 1150B 1150A 1250B 1250A 1350B 1350A 1450B 1550B 1450A 1550A LS-0450B 0450A LO LEVEL HIGH LEVEL HI-HI-LEVEL LO-LO-LEVEL 1540A 1440A 1540B 1440B 0440A 0440B 1340A 1340B 1240A 1240B 1140A 1140B 0640A 0640B 0641B 0641A 1141B 1141A 1241B 1241A 1341B 1341A 0441B 0441A 1441B 1541B 1441A 1541A 1251A 1251B 0450A 0450B LC-1550A 1450A 1550B 1450B 1350A 1350B 1250A 1250B 1150A 1150B 0650A 0650B 0451A 0451B LC-1551A 1451A 1551B 1451B 1351A 1351B 1251A 1251B 1151A 1151B 0450A 0450B LG-1550A 1450A 1550B 1450B 1350A 1350B 1250A 1250B 1150A 1150B 0650A 0650B LS-1542A 1442A 1542B 1442B 1342A 1342B 1242A 1242B 1142A 1142B 0450A 0450B LT-1550A 1450A 1550B 1450B 1350A 1350B 1250A 1250B 1150A 1150B 0650A 0650B LEVEL CONTROLLERS GAUGES LEVEL TRANSMIT LEVEL FD 6HD-V41-1 OR 5HD-V39-1 DETAIL C MISC. VENTS & DRAINS NOTES:

1. SEE TYP. DETAILS ON THIS DWG. FOR INSTRUMENT, DRAINS & VENT LINE AND VALVE NUMBERS.
2. CONTROL VALVE SUPPLIED WITH REDUCERS.
3. PIPING BY I&C, VALVES SUPPLIED BY MECHANICAL.
5. VALVES 5HV-F1-1 & 5HV-F2-1 WERE MODIFIED VIA FCR-M-1943 TO FAIL CLOSED ON LOSS OF AIR PRESSURE, BUT THEY WILL FAIL OPEN ON LOSS OF (TYP.)

6HD-V43-1 6HD-V43-1 6HD-V43-1 (TYP.)

(TYP.)

6HD-V43-1 LT-0650A, LT-0650B LT-1150A LT-1350A, LT-1350B LT-1450B VENT LT-1150B LT-1250A LT-1250B LT-1550B DRAIN 5HD-V39-1 FLOW DIAGRAM LEGEND REFERENCE DRAWINGS CAR-2165-G-041 LEGEND DRAINS VENTS (TYP.)

(TYP.)

HTR #5 HTR #4 HTR #3 HTR #2 HTR #5 HTR #5 HTR #4 HTR #3 HTR #2 DETAIL D HTR #2 HTR #3 HTR #4 8"

& TABULATION (M3)

SEE DETAIL A (N11) 6HV-U19-1(TYP.)

(TYP.)

FD CAR-2165-G- 045 HD TO FW PUMP L.O.

CAR-2165-G-088(C4)

ED F.O.

6" 5HV-X1-1 8"

FD 24" FD PUMP 1A-NNS HEATER DRAIN FD F.O.

16" EMERG DR CONN (CAPPED) 1A-NNS 6HD-S1-1 FD F.C.

(DETERMINATED)

I& C MECH FD FD FD (E2)

FD F.C.

FD LP HEATER 4 F.C.

EMERG DR CONN (CAPPED) 1A-NNS HP HEATER 5 FD 1A-NNS SEPARATOR TANK REHEATER MOISTURE FD DRAIN MOISTURE SEPARATOR 1A-NNS REHEATER 10" FD TO SAMPLING ASSEMBLY FD CAR-2165-G- 089 (A13)

BY I&C FD 1A-NNS DRAIN MOISTURE SEPARATOR TANK (TYP.)

SEE DET D (A3)(TYP.)

C EL. 300'-4 L

EL. 294'-5 C

L 6HV-U13-1(TYP.)

(TYP.)

SEE DET D (A3)(TYP.)

TEMP STNR (TYP.)

(TYP)

SEE DET A 6HD-V41-1 6HD-V46-1 (SEE NOTE 2) 24" FD 2" VENT (TYP.)

PUMP 1B HTR. DRN.

(TYP.)

24" 6"

(A3)(TYP.)

SEE DET. D 6"

L C EL.294'-5 EL.300'-4 L

C F.C.

FD FD MECH I& C EMERG DR CONN (CAPPED) 1B-NNS CAR-2165-G-088(D4) 16" 24" FD L.O.

FD FD FD F.O.

BY I&C FD CAR-2165-G- 089 TO SAMPLING ASSEMBLY 10" MOISTURE 1B-NNS DRAIN FD EMERG DR CONN (CAPPED) 1B-NNS HP HEATER 5 LP HEATER 4 FD 6HV-U19-1(TYP.)

F.C.

FD FD FD SEPARATOR TANK F.C.

FD TANK REHEATER MOISTURE SEPARATOR 1B-NNS DRAIN MOISTURE SEPARATOR 1B-NNS REHEATER FD FD FD FD F.C.

(TYP.)

(A13)

(TYP.)

(TYP.)

(TYP.)

(TYP.)

TAB (M3)

(N9) &

SEE DET A TAB (M3)

SEE DET A SEE DET D (A3)(TYP.)

HD PUMP DISCH VENT 2" VENT 1 '"

(TYP.)

(TYP.)

TEMP STNR 6HD-S2-1 (SEE NOTE 2) 6HV-V56-1 6HV-V57-1 6HV-V58-1 6HV-V59-1 A17,B13,D14,D16 E4,E7,G4,G7

(

)

1 '"

(TYP.)

(TYP.)

(TYP.)

6" 6"

V L.S. FOR EXT. STM.

SHUTOFF (TYP.)

12" 8"

4" (TYP.)

(TYP.)

FD 4"

(TYP.)

(TYP.)

1 '"(TYP.)

(TYP.)

(TYP.)

5HV-X2-1 10" (TYP.)

(TYP.)

FD FD FD 8"

(DETERMINATED)

NNS TO SEC. SAMPLING SAMPLE COND. RACK 1X-NNS CPL-2165-G-089S02 (B10)

TO SEC. SAMPLING SAMPLE COND. RACK 1X-NNS CPL-2165-G-089S02 (B10)

DR DR 6HV-U13-1 8"

ELECTRICAL POWER TO THE SOLENOID VALVES.

5HV-V53-1 6HD-V11-1 6HD-V36-1 6HD-V12-1 6HD-V16-1 6HD-V15-1 6HD-V14-1 6HD-V13-1 6HD-V35-1 6HD-V5-1 6HD-V8-1 6HD-V7-1 6HD-V6-1 6HD-V9-1 6HD-V10-1 6HV-V33-1 6HV-V36-1 6HD-V21-1 6HD-V19-1 6HV-V27-1 6HV-V30-1 6HV-V34-1 6HV-V35-1 6HV-V31-1 6HV-V32-1 6HD-V22-1 6HD-V20-1 FT 0450 B

TW 0450 B2 PX 1150 B

FE 1150 B

FT 1150 B

FX 1150 B

PX FX TE 1250 B

LCV 0650 A

LCV 1151 A

TW 0450 B1 PX 0449 B

TE 0450 B

PX LCV 0450 B

PT 0450 B

PX 0649 B

FE 0650 B

PT 0650 B

TE 1150 B

LCV 1150 B

TE 0650 B

TW 0650 B2 FX FT 0650 B

PX 0651 B

PX TW 0650 B1 TE 1250 B1 PT 1250 B

PX 1249 B

FCV 1255 B

PI 1255 B

PDT 1255 B

FE 1255 B

PT 1255 B

PX PS 1255 B

FT 1255 B2 PDI 1250 B

LCV 1250 B

FX 1255 B1 TE 1255 B

FT 1255 B1 PX 1255 B1 TE 0650 A

TW 0650 A1 FE 0650 A

PX PT 0650 A

PX 0651 A

FX FT 0650 A

PX 0449 A

LCV 0450 A

F.C.

PT 0450 A

PX TW 0450 A1 FE 0450 A

FT 0450 A

TW 0450 A2 PX TE 0450 A

LCV 1150 A

TE 1150 A

FE 1150 A

FT 1150 A

FX 1150 A

PX 1150 A

PX FX TW 0650 A2 PX 0649 A

LCV 1250 A

PX 1255 A1 FT 1255 A1 PT 1255 A

FX 1255 A1 FT 1255 A2 FE 1255 A

TE 1255 A

PI 1255 A

PDT 1255 A

PX 1249 A

PDI 1250 A

PT 1250 A

PS 1255 A

FCV 1255 A

TE 1250 A

TE 1250 A1 PX

PDS, PDT,PT PI,PS TW 1550 A

LCV 1551 A

LCV 1551 B

LCV 1451 B

LCV 1151 B

LCV 0451 A

FE 1550 A

PX 1550 A

LCV 1351 A

LCV 1251 A

PX 1551 A

FT 1550 A

FX 1551 A

TE 1550 A

LCV 1451 A

LCV 1550 A

LCV 0451 B

FE 1550 B

FT 1550 B

LCV 0650 B

LCV 1251 B

LCV 1550 B

PX 1551 B

FX 1551 B

TW 1550 B

LCV 1351 B

LCV 1450 A

PX 1450 A

TE 1450 A

LCV 1350 A

TE 1350 A

TE 1550 B

LCV 1450 B

PX 1550 B

PX 1450 B

TE 1450 B

LCV 1350 B

TE 1350 B

PX 1350 B

FE 0450 B

1x3/8 RED 24x20 RED 1x3/8" RED 24x20 RED PX PX PX PX PX FT FT LC LT LG LT LC LS LS LS LG LT FT FT PT PX LX PX PX LX LX LX LX LX LX LX LX LX LX LX LX LX LX LX PX PX LX LS LC LG LT LT LC 5HD-V24-1 6HD-V28-1 6HD-V60-1 6HD-V26-1 6HD-V27-1 6HD-V58-1 5HD-V23-1 6HD-V25-1 6HD-L8-1 6HD-L6-1 6HD-L24-1 6HD-L26-1 6HD-L11-1 6HD-L15-1 6HD-V80-1 6HD-V79-1 6HD-V77-1 6HD-V78-1 5HD-L4-1 5HD-V51-1 5HV-F4-1 6HD-V50-1 6HD-V41-1 6HD-V41-1 6HV-V47-1 6HD-V48-1 6HD-V48-1 6HD-V45-1 6HD-V45-1 6HD-V41-1 6HD-V41-1 6HD-V52-1 6HD-V32-1 6HD-V46-1 6HD-V41-1 6HD-V41-1 6HD-V52-1 6HD-V52-1 6HD-V50-1 6HD-V45-1 6HD-V45-1 5HD-V51-1(TYP) 6HD-V41-1 6HV-V47-1(TYP) 6HV-V48-1 6HD-V41-1 6HD-V41-1 6HD-V41-1 6HD-V41-1 6HD-V52-1 6HD-V52-1 6HD-V29-1 6HD-V52-1 5HV-F3-1 6HV-V4-1 6HD-V49-1 6HV-V4-1 6HD-L23-1 5HD-L2-1 6HD-L25-1 6HD-V41-1 6HD-V41-1 6HV-V45-1 6HV-V4-1 6HV-V19-1 6HV-V51-1 6HD-V48-1 6HD-V48-1 6HV-V45-1 6HD-V48-1 6HD-V48-1 6HV-V50-1 6HV-V50-1 6HD-V48-1 6HD-V48-1 6HD-V41-1 6HV-V50- 1 6HD-V41-1 6HV-V46-1 6HV-V46-1 6HD-V47-1 6HD-V47-1 6HV-V49-1 6HV-V49-1 6HD-V41-1 6HD-V47-1 6HV-V49-1 6HV-V49-1 6HD-V41-1 6HD-V41-1 6HD-V41-1 6HD-V41-1 6HV-V19-1 6HD-V51-1 6HV-V4-1 6HD-V48-1 6HD-V48-1 6HV-V45-1 6HV-V45-1 6HD-V47-1 6HV-V46-1 5HV-V2-1 6HV-V3-1 6HV-V26-1 6HV-V7-1 6HV-V29-1 5HD-V4-1 6HD-V59-1 6HV-V38-1 6HD-V52-1 6HV-V3-1 6HV-V25-1 6HD-V57-1 6HV-V7-1 6HV-V7-1 6HV-V28-1 5HV-V1-1 6HV-V3-1 6HV-V3-1 6HV-V3-1 6HV-V3-1 6HV-V3-1 6HV-V3-1 6HV-V7-1 6HV-V7-1 6HV-V7-1 6HV-V7-1 6HV-V7-1 6HV-V7-1 5HD-V2-1 6HV-V3-1 6HD-V52-1 6HV-V37-1 6HD-V41-1 6HD-V41-1 6HD-V41-1 6HD-V41-1 6HD-V41-1 6HV-V54-1 6HV-V51-1 6HV-V42-1 6HV-V51-1 6HV-V54-1 6HV-V15-1 6HV-V15-1 6HV-V54-1 6HV-V41-1 6HV-V40-1 6HV-V19-1 6HV-V43-1 6HV-V15-1 6HV-V15-1 6HV-V15-1 6HV-V15-1 6HV-V15-1 6HV-V15-1 6HV-V15-1 6HV-V15-1 6HV-V50- 1 6HV-V15-1 6HV-V11-1 6HV-V54-1 6HV-V19-1 6HV-V15-1 6HV-V15-1 6HV-V15-1 6HV-V15-1 5HD-L3-1 5HD-L1-1 5HV-F2-1 5HV-F1-1 5HD-C4-1 6HD-C6-1 6HD-C1-1 6HD-C5-1 5HD-C3-1 6HD-L7-1 6HD-L5-1 6HD-L9-1 6HD-L13-1 6HD-F2-1 6HD-F1-1 6HD1-140-1 6HD1-139-1 6HD10 1 6HD1-106-1 6HD14-111-1 5HV4 1 6HD4 1 5HD10 1 6HD12 1 6HD20 1 6HD24-93-1 6HD20-40-1 6HD4-79-1 6HD4-99-1 6HD1-126-1 6HD1-104-1 6HD12 1 6HD1-81-1 6HD1 1/2-85-1 6HV3 1 6HD1-81-1 6HD14-36-1 6HV1 1/4-52-1 6HV1 1/4-50-1 6HV1 1/2-8-1 6HD16-37-1 6HD1 1/2-84-1 6HD1-128-1 6HV2-11-1 6HD2 1 6HD12 1 5HV12 1 5HV6-32-1 5HD10 1 5HD10-7-1 5HV4 1 6HV1 1/4-3-1 5HD2-95-1 6HD2-94-1 6HD12-23-1 5HV 2-1 6HD10 1 6HD10 1 6HD10 1 6HV3 1 6HD1-130- 1 6HD10 1 6HV3 1 6HD12 1 6HD1-81-1 6HV2 1 6HD1-129-1 6HD16 1 6HD12 1 6HD1-104-1 6HD12-34-1 6HD1-125-1 6HD4-98-1 6HD1-104-1 6HD4-100-1 6HD4 1 6HD4-98-1 6HD24-92-1 6HD4 1 6HD20 1 6HD12 1 5HD10 1 6HD20-31-1 6HD1-81-1 6HV3-27-1 6HD1 1/2-85-1 6HD1-127-1 6HV2-9-1 6HD14 1 6HD1-81-1 6HD16-28-1 6HD1-108-1 6HV1 1/4-52-1 6HD1 1/2-84-1 6HD2 1 6HD12 1 6HD1-109-1 6HV1 1/4 1 5HD12-3-1 5HV6-57-1 6HD1-81-1 5HV4 1 5HD10-2-1 6HV1 1/4 1 6HD2-94-1 5HD2-95-1 6HV2 1/2 1 6HV3 1 6HD12-15-1 6HD10 1 6HD10 1 6HD10 1 5HD12-1-1 5HV4 1 5HV3 1 6HV1-65-1 6HV1-64-1 6HV1-66-1 6HV1-67-1 6HV2-18-1 6HV1 1/2-13-1 6HV1 1/2-8-1 6HV1 1/4-3-1 6HD1-81-1 6HD1-81-1 5HD1-11-1 6HD1-81-1 6HD1-81-1 6HD3/4-132-1 5HD3/4-131-1 5HD1-11-1 5HD1-11-1 5HD1-11-1 6HD1-81-1 6HV1 1/2-13-1 6HV3-14-1 6HD1 1/2 1 6HD6-46-1 6HD6 1 6HD1 1/2 1 6HD10-50-1 6HV2 1/2-7-1 6HV3-12-1 6HV4-22-1 6HV4-17-1 6HV1 1/2-13-1 6HV3-16-1 6HV1 1/4 1 6HV1 1/4 1 6HV1 1/4-49-1 6HD1-81-1 6HD1 1/2-86-1 6HV4-19-1 6HD1 1/2-86-1 6HV4-21-1 6HD1-107-1 6HV1 1/4-49-1 6HD6-54-1 6HD1 1/2 1 6HD6 1 6HD1-106-1 6HV2-18-1 6HV2-18-1 6HV1 1/4-54-1 6HD8-47-1 6HD1 1/2-87-1 6HD8-55-1 6HD1 1/2 1 6HV1 1/4-48-1 6HD12 1 6HV2 1 6HV1 1/4 1 6HV2-45-1 6HD10 1 6HV1 1/4 1 6HD14 1 6HV4-24-1 6HD1-81-1 6HV1 1/4-48-1 6HD12-59-1 6HD10-58-1 6HV2 1 6HV1 1/4 1 6HV2 1 6HV1 1/4 1 6HD10 1 6HD14 1 6HV4-25-1 6HV2-43-1 6HD1-105-1 6HD1 1/2-88-1 6HD1 1/2-88-1 6HV4-23-1 6HV4-26-1 6HD16-65-1 6HD16-69-1 6HD12-64-1 6HD16-63-1 6HD12-62-1 6HD14-53-1 6HD10-49-1 5HV6-36-1 6HD14-18-1 6HD24-33-1 6HD16-30-1 5HD14-5-1 5HV6-59-1 6HD10-113-1 5HD14-10-1 6HD16-39-1 6HD24-42-1 6HD14-26-1 6HD10-57-1 6HD16-67-1 6HD12-68-1 6HD14-61-1 6HD12-66-1 6HD10-114-1 6HV2-4-1 6HD14-110-1 6HD1-104-1 6HD4-99-1 137 133 162 46 42 130 40 47 43 41 131 44 38 33 36 32 45 39 35 37 34 51 53 140 49 48 132 139 180 138 52 143 134 135 136 181 142 141 50 163 6HD-L20-1 6HD-L12-1 6HD-L19-1 6HD-L16-1 6HD-L22-1 6HD-L21-1 6HD-L17-1 6HD-L10-1 6HD-L18-1 6HD-L14-1 DETAIL B1 DETAIL B2 (TYP)

(N9)&TAB (M3) (TYP) 6HD4-101-1 ONLY)

(TYP. FOR MSRDT LEVEL SWITCHES CONTROL SECTION CONTROL SECTION (TYP) 6HD-V41-1 COND NOTE:

4 1B-NNS ONLY HEATERS 4 1A-NNS AND NORMALLY CLOSED ON THESE TWO VALVES ARE

& B ONLY FOR FT-0650A ONLY FOR FT-0450A ONLY FOR FT-0450A MSRDT ONLY)

(TYP. FOR 5HD-V38-1 MSRDT ONLY)

(TYP. FOR 5HD-V39-1 OR 6HD-V41-1 (TYP) 6HD-V41-1 USE FOR SYS. 5 OR 6 AS APPLICABLE)

(UNLESS OTHERWISE NOTED, PUMP 1B-HTR. DRN.

F.C.

FD FD 16" NNS 6HD-L8-1 6HD-V14-1 6HD12 1 PUMP 1A-NNS HEATER DRAIN 16" F.C.

FD 6HD-L6-1 PS 1255 A

6HD16 1 6HD12 1 A

1255 FE 6HD12-34-1 6HD12-141-1 A

1255 TE 6HD-V25-1 6HD-V7-1 A

1250 LCV FD 6HD-V8-1 6HD12-143-1 6HD12-145-1 6HD12-146-1 6HD12-144-1 B

1250 LCV 6HD-V13-1 6HD12-43-1 B

1255 FE B

1255 TE 6HD12-142-1 CS SS CS SS SS CS SS SS CS CS SS CS REMAIN AS CARBON STEEL.

NOTE: DRAIN LINES, INSTRUMENT TAPS ETC (N11) &

CS HDR MATERIALS PUMPS DISCH.

FOR HTR DRAIN SEE DET "F"(N5)

DETAIL F (I5) 6HD-V26-1 SS CS 6HD4-98-1 6HD4-99-1 TO TEST CONN.

(TYP)

CONT'D BY I&C 6HD1-81-1 AND MS DRAIN TANKS HEATERS 5A,5B AND MSR NORMALLY CLOSED FOR THESE VALVES ARE HD PUMP 1B SEAL WATER HD PUMP 1A SEAL WATER 5HD-V81-1 CS SS 5CF1-108-1 5HD1-147-1 6HD-V82-1 6CF1-109-1 6HD1-148-1 CS SS CS SS 6HD-V84-1 6CF1-111-1 6HD1-150-1 SS CS 5HD-V83-1 5CF1-110-1 5HD1-149-1 TABULATION FOR DETAIL "A" & "E" (M11) 5-G- 0053 AMINE INJECTION (M11) 5-G-0053 AMINE INJECTION (N11) 5-G-0053 AMINE INJECTION (N11) 5-G- 0053 AMINE INJECTION 5HD12-6-1 5HV-V52-1 5HV4 1 5HV4-56-1 5HV4-61-1 5HV-V60-1 5HV2-68-1 5HV2-69-1 5HV-V61-1 18" 5HD18-151-1 5HV4 1 18" 5HD18-152-1 6HD-C2-1 LEVER ARMS ARE MECHANICALLY RESTRAINED.

TO REMOVE THEIR DISC AND OPERATORS. SHAFTS AND

6. VALVES 6HD-C1-1 & 6HD-C2-1 HAVE BEEN MODIFIED 6HD8-153-1 6HD-V17-1 12"Ú 6HD-V18-1 6HD-154-1 12"Ú 6HV1 1/2-8-1 (TYP.)

REV DESCRIPTION AND DATED ELECTRONICALLY SIGNED APPROVED AND DATED ELECTRONICALLY SIGNED 41 INCORPORATED: EC#74907 (E1,E4,E6,E10) 42 AND EC 93054 (C3,C7,K17-K19)

INCORPORATED: EC 87011 (G3-G7)

SIGNED ELECTRONICALLY 43 INCORPORATED: EC 279938 (E1,C4,C7,E10)

DUKE ENERGY 5-G-0046

COOLER FAN CONTAINMENT TABLE CONTINUES AT (N9)

CONTINUATION OF TABLE FROM (N6)

NOTES:

3 B

A C

D E

F 3"

(I8,I9,I10)

DETAIL 6 52" 54" 24" 24" LINE NO.

VALVE NO LINE NO.

LINE NO.

F A

3SW6-82SA-1 3SW6-80SB-1 3SW8-128SA-1 3SW8-338SB-1 D

3SW-U7SA-1 3SW-U8SB-1 3SW-U9SA-1 3SW-U10SB-1 7SW1-1724-1 7SW1-1723-1 7SW1-1722-1 7SW1-1721-1 E

C 3SW-V363SA-1 3SW-V366SB-1 3SW-V364SA-1 3SW-V365SB-1 3SW1-381SB-1 3SW1-380SA-1 3SW1-382SB-1 3SW1-379SA-1 B

7SW-R13-1 TO FD INST. OR DRAIN TEST VENT, TEST CONN DETAIL 5 DETAIL 4 DETAIL 1 DETAIL 3 DETAIL 2 FD 2

3 TYPICAL EXCEPT WHERE NOTED OTHERWISE FD (M10)

CAR-2165-G-056 TO FIRE PROT. HDR.

DRAIN TAB SOURCE E

7SWf-730-1 7SWf-731-1 7SWf-732-1 7SWf-733-1 7SW-V549-1 7SW-V548-1 7SW-V547-1 7SW-V546-1 F

7SW1-692-1 7SW1-691-1 7SW1-690-1 7SW1-689-1 LINE NO.

LINE NO.

VALVE NO (I16,J16) 7SW2 1/2-677-1 7SW2 1/2-676-1 7SW2 1/2-675-1 7SW2 1/2-674-1 7SW4-532-1 7SW4-530-1 7SW6-289-1 7SW2 1/2-665-1 7SW2 1/2-664-1 7SW2 1/2-663-1 7SW2 1/2-662-1 7SW4-531-1 7SW4-529-1 7SW6-346-1 AH-39 7SW2 1/2-673-1 7SW2 1/2-672-1 7SW2 1/2-671-1 7SW2 1/2-670-1 7SW4-528-1 7SW4-526-1 7SW6-315-1 7SW2 1/2-661-1 7SW2 1/2-660-1 7SW2 1/2-659-1 7SW2 1/2-658-1 7SW4-527-1 7SW4-525-1 7SW6-347-1 AH-38 7SW2 1/2-669-1 7SW2 1/2-668-1 7SW2 1/2-667-1 7SW2 1/2-666-1 7SW4-524-1 7SW4-522-1 7SW6-310-1 7SW2 1/2-657-1 7SW2 1/2-656-1 7SW2 1/2-655-1 7SW2 1/2-654-1 7SW4-523-1 7SW4-521-1 7SW6-333-1 N

M L

K J

I H

G F

E D

C B

A AH-37 ITEM NO.

EQUIP.

EQUIP.

EQUIP.

EQUIP.

AH-3 AH-2 2SW3/4-694SB-1 AH AG AF AE AD AC AB AA AH-1 ITEM NO.

AH-4 2SW3/4-695SB-1 2SW3/4-696SB-1 2SW3/4-697SB-1 2SW3/4-698SB-1 2SW3/4-699SB-1 2SW3/4-700SB-1 2SW3/4-701SB-1 2SW3/4-709SA-1 2SW3/4-708SA-1 2SW3/4-707SA-1 2SW3/4-706SA-1 2SW3/4-705SA-1 2SW3/4-704SA-1 2SW3/4-703SA-1 2SW3/4-702SA-1 2SW3/4-717SA-1 2SW3/4-716SA-1 2SW3/4-715SA-1 2SW3/4-714SA-1 2SW3/4-713SA-1 2SW3/4-712SA-1 2SW3/4-711SA-1 2SW3/4-710SA-1 2SW3/4-725SB-1 2SW3/4-724SB-1 2SW3/4-723SB-1 2SW3/4-722SB-1 2SW3/4-721SB-1 2SW3/4-720SB-1 2SW3/4-719SB-1 2SW3/4-718SB-1 2SW4-470SB-1 2SW4-614SB-1 2SW6-615SB-1 2SW4-613SB-1 2SW4-471SB-1 2SW6-612SB-1 2SW-V505SB-1 2SW1-635SB-1 2SW10-56SB-1 2SW-V509SB-1 2SW1-639SB-1 2SW4-468SB-1 2SW-V508SB-1 AH-4 NO.

ITEM AH-1 N

O P

Q R

S T

U V

W X

Y 2SW4-456SB-1 2SW1-621SB-1 2SW-V491SB-1 2SW10-51SB-1 2SW1-617SB-1 2SW-V487SB-1 2SW6-588SB-1 2SW4-458SB-1 2SW4-589SB-1 2SW6-591SB-1 2SW4-590SB-1 2SW4-459SB-1 AH-2 2SW-V496SA-1 2SW4-462SA-1 2SW1-627SA-1 2SW-V497SA-1 2SW10-37SA-1 2SW1-623SA-1 2SW-V493SA-1 2SW6-596SA-1 2SW4-465SA-1 2SW4-597SA-1 2SW6-599SA-1 2SW4-598SA-1 2SW4-464SA-1 AH-3 2SW-V502SA-1 2SW4-449SA-1 2SW1-633SA-1 2SW-V503SA-1 2SW10-35SA-1 2SW1-629SA-1 2SW-V499SA-1 2SW6-604SA-1 2SW4-453SA-1 2SW4-605SA-1 2SW6-607SA-1 2SW4-606SA-1 2SW4-452SA-1 Z

2SW1-632SA-1 2SW4-602SA-1 2SW6-603SA-1 2SW-V501SA-1 2SW1-631SA-1 2SW4-450SA-1 2SW-V500SA-1 2SW1-630SA-1 2SW4-601SA-1 2SW6-600SA-1 2SW-V498SA-1 2SW1-628SA-1 2SW10-34SA-1 AH-3 2SW1-626SA-1 2SW4-594SA-1 2SW6-595SA-1 2SW-V495SA-1 2SW1-625SA-1 2SW4-461SA-1 2SW-V494SA-1 2SW1-624SA-1 2SW4-593SA-1 2SW6-592SA-1 2SW-V492SA-1 2SW1-622SA-1 2SW10-32SA-1 AH-2 2SW1-620SB-1 2SW4-586SB-1 2SW6-587SB-1 2SW-V489SB-1 2SW1-619SB-1 2SW4-455SB-1 2SW-V488SB-1 2SW1-618SB-1 2SW4-585SB-1 2SW6-584SB-1 2SW-V486SB-1 2SW1-616SB-1 2SW10-50SB-1 M

L K

J I

H G

F E

D C

B A

AH-1 ITEM NO.

AH-4 2SW10-55SB-1 2SW1-634SB-1 2SW-V504SB-1 2SW6-608SB-1 2SW4-609SB-1 2SW1-636SB-1 2SW-V506SB-1 2SW4-467SB-1 2SW1-637SB-1 2SW-V507SB-1 2SW6-611SB-1 2SW4-610SB-1 2SW1-638SB-1 DETAIL 8 (B8,B9,B12,B13)

(B16-B19)

DETAIL 7 TURBINE BUILDING CONTAINMENT FAN COIL UNIT (REF)

I L

K H

J N

M C

G F

A B

E D

N M

L K

H T

S X

Y Z

R U

V W

J AE AF AG AH AD AC AB AA O

P Q

C E

F G

D A

B (REF)

V FD FD V

V V

V FD FD FD FD FD FD DISMANTLING FLG'S (FOR AH-2 ONLY)

V (REF)

(I19)(TYP)

SEE TAB.

(TYP)

(TYP)

(TYP)

FD FD FD 3

S M

M RESERVOIR TO AUX TO AUX RESERVOIR S

2" CONN.

24" CONN.

S DET. 1 CVCS CHILLERS-NNS DET. 1 F.C.

S G

M S

S M

3 S

S DET. 1 DET. 1 FD L.O.

G G

V G

FROM DIESEL GEN.

NO. 1B COOLING CAR-2165-G- 133(E18)

FROM DIESEL GEN.

NO. 1A COOLING CAR-2165-G- 133(E9)

TO DIESEL GEN.

NO. 1B COOLING CAR-2165-G- 133(C17)

CAR-2165-G- 133(C8)

NO. 1A COOLING TO DIESEL GEN.

3 G

COOLING WTR. RETURN REM #3542 CAR-2165-G-105(G8)

CAR-2165-G-048(E12)

WATER DISCH. HDR.

TO NORMAL SERVICE G

3 V

V V

3 DET 3 G

FD G

3SW-S2SB-1 3SW-U4SB-1 L.O.

G G

3 B

V V

VENDOR CHILLER BY CVCS 1A-NNS 1B-NNS S

L.C.

FD L.O.

FD FD TO ATM (TYP)

FD FD L.C.

FD FD FD UNIT 2 TANK BLDG EMERGENCY S.W.

GRAB SAMPLE "B"

& FD FD COOL WTR RETURN REM# 3525 DWG. 5-G-105 (I8)

FROM CONTAINMENT NON-SAFETY FAN COIL UNITS (E19)

FD DET. 1 L.O.

FD FD L.O.

L.O.

FD FD DR. CONN.

1" PLUGGED FD RETURN HDR 'B' RETURN HDR 'A' FD SUPPLY HDR "A" SUPPLY HDR "B" RAB V

COMPONENT C.W.

HEAT EXCH.

1B-SB CAR-2168-G499S02(F15)

G G

FROM CHILLER G-052(I14)

(A9)

FROM CONT.

3 B

CAR-2168-G-499S02(F4)

G FD FD 1B-SB SW BOOSTER PUMP (L8)

(TYP. 3)

GEAR COOLER CHARGING PUMP 3SW-U2SB-1 F.C.

M R

R M

32 M

M 30 (1A-SB)

(1B-SB)

(1B-SA)

(1A-SA)

AH-2 COOLER FAN CONTMT.

6" 6"

4" 4" 4" 4" 4" 4" 4" 4" 6"

6" 6"

6" 4"

4" 4"

4" 4"

4" 6"

6" CONTMT.

FAN COOLER AH-4 SEE DET. 8 (N3)(TYP)

(TYP. 3)

LUBE OIL COOLER CHARGING PUMP FD FD DET. 3 3

(K9)

(L8) 3 DET. 3 (K8)

(L9) 3 5-G-048 (G3)

& AFTERCOOLERS COMPRESSORS FROM AIR 3

(L12)

(K5) 2 (TYP)

SEE DET.

FD 3

2 M

R 2

3 R M 31 M

FD (N3)(TYP)

SEE DET. 8 AH-1 COOLER FAN CONTMT.

6" 6"

4" 4" 4" 4" 4" 4" 4" 4" 6"

6" 6"

6" 4"

4" 4"

4" 4"

4" 4"

4" 6"

6" FD R

M G

G 3

(I6)

TO FIRE PROT. HDR.

CAR-2165-G-056 3

2 R

M M

29 M

25 3SW-J1SA-1 L.O.

1364-94905 BY VENDOR (TYP.3)

FD SW BOOSTER FD 26 M

DET. 3 L.O.

A EMERGENCY SERVICE WATER INTAKE SCREENING STRUCTURE BAY 8 CONTMT.

FAN COOLER AH-3 (1A-SA)

(1B-SA)

FD FD FD FD (1B-SB)

(1A-SB)

RAB TURB BLDG FD FD FD FD 1A-SA PUMP 3SW-S1SA-1 NOTE 1 FD 3SW-U1SA-1 FD (H8)

CAR-2165-G- 045 S.G. A.F.W. PUMP BACK-UP LINE TO N.C.

M (N12)

DETAIL 6 M

M M

N.C.

DETAIL 6(N12)

N.C.

N.C.

BACK-UP LINE TO S.G. A.F.W. PUMP CAR-2165-G- 045 (H9)

A.F.W. PUMP 1A-SA SUCT.

BACK-UP LINE TO S.G.

6(N12)

DETAIL N.C.

N.C.

N.C.

N.C.

TO HVAC CHILLER WC2(1B-SB)

FD F.C.

WC2(1B-SB)

FROM HVAC CHILLER COOLERS (F11)

CHARGING PUMP LUBE OIL & GEAR CHARGING PUMP CHARGING PUMP LUBE OIL & GEAR COOLERS (F8)

LUBE OIL & GEAR COOLERS (F10)

V FD A

CHARGING PUMP LUBE OIL & GEAR COOLERS (F8)

REACTOR AUXILIARY BUILDING V

DET 3 FD G

FROM HVAC CHILLER WC2(1A-SA)

CAR-2168-G- 498S02(F15)

G COOLERS (F9)

LUBE OIL & GEAR CHARGING PUMP COOLERS (F11)

LUBE OIL & GEAR CHARGING PUMP (H7)

CAR-2165-G- 045 3

G 3

3 G

3SW-U3SA-1 G

2"CONN 24"CONN 3

FIRE PROTECT SYS.

CAR-2165-G-056 (L3) 3 (M3)

CAR-2165-G- 056 FIRE PROTECT SYS.

B 3

TO HVAC CHILLER WC2(1A-SA) CAR-2168-G- 498S02(F4)

A FD (B8)

CAR-2165-G- 105 SUPPLY COOLING WATER FD FD FD 1A-SA HEAT EXCH.

COMPONENT C.W.

FD HVAC BY MECH BY FROM NORMAL SERVICE WTR HDR CAR-2165-G- 048 (H17)

UNIT 1 TANK BLDG.

V V

TO 5-G- 052(I13)

CHILLER (B9)

CHILLER 5-G- 052(I13)

TO MAKE-UP TO EVAP AIR COOLER 1X-NNS CAR-2168-G-517S03(D1)

COIL UNITS (E15)

NON-SAFETY FAN TO CONTAINMENT 2165-G- 089(H1)

SAMPLE PANEL CAR-TO WET LAY-UP COOL WTR SUPPLY TO REM# 3525 DWG. 5-G-105 (B8)

FROM CHILLER 5-G-052(I14)

(B9)

L.O.

FD 3

N M

1 2

3 L

K J

I H

4 5

6 7

8 9

G F

E D

C B

A 1

2 3

4 5

6 7

8 9

10 11 12 13 14 15 16 17 18 19 HARRIS NUCLEAR PROJECT - UNIT 1 CONTROL OF THE ELECTRONIC DRAWING DATABASE.

REVISIONS TO THIS DOCUMENT SHOULD BE DONE USING THE CAD/E SYSTEM TO ASSURE PROPER THIS DRAWING HAS BEEN PRODUCED AND IS CONTROLLED ON THE NED CAD/E SYSTEM. ANY NUCLEAR SAFETY RELATED (Q-LIST)

YES NO PARTIAL F.P.-Q R.W.-Q NUCLEAR ENGINEERING DEPARTMENT - RALEIGH, N.C.

DESCRIPTION TITLE:

PLANT:

REV NONE SCALE:

DWG NO.

N M

L K

J I

H 10 11 12 13 14 15 16 G

E D

17 18 19 C

B A

(AUX. RESERVOIR)

S A BAY 6 V

V 1A-SA 1B-SB V

V G-047 CAR-2165 EMERGENCY SERVICE WATER PUMPS EMERGENCY SERVICE WATER & COOLING TOWER MAKE-UP WATER INTAKE STRUCTURE (MAIN RESERVOIR)

BAY 8 BAY 6 L.C.

L.C.

L.O.

L.O.

F.O.

L.O.

F.O.

FOR ISI HYDRO TEST G

G TO CTMU PUMP 2X-NNS (INTAKE STRUCT.)

FROM EMERG.

SCREEN WASH PUMP CAR-2165-G- 308(C17)

CAR-2165-G- 308(G11)

STRAINER SUMP PIT TO CTMU A

A 30" 30" 3SW-J2SA-1 B

B 3SW-J3SB-1 TO SCREEN WASH PUMP 1B-SB CAR-2165-G- 308(C11)

TO SCREEN WASH PUMP 1A-SA CAR-2165-G-308 3SW-U12SB-1 DETAIL 5 B

3 3SW-J8SB-1 G

BY INST.

BY INST.

3SW-J7SA-1 G

BY INST.

S S

3 3SW-S22SB-1 S21SA-1 3SW-DETAIL 4 3SW-U11SA-1 FAN CONTMT COIL UNIT AH-39 (1A-NNS)

(1B-NNS)

CONTMT FAN COIL UNIT AH-38 (1A-NNS)

(1B-NNS)

(1B-NNS)

(1A-NNS)

AH-37 COIL UNIT FAN CONTMT FD INSIDE REACTOR CONTAINMENT OUTSIDE REACTOR CONTAINMENT T

T F.C.

F.C.

FD V

FD 4"

4" 28 M

27 M

M R

FD R

M 2

3 DETAIL 1 TEST CONN G

DET. 1 (TYP)

DET. 1 (TYP) 4" 4"

4" 4"

4" 4"

4" 4"

4" 4"

4" 4"

SEE DET 7 (L3)

(L3)

DET 7 SEE G

G DET. 1 TEST CONN.

CONN.

TEST 2

M 92 TEST DRAIN 2

T DET. 1 DET. 1 FROM NORMAL SW HDR (J3)

DET. 1 (TYP)

G G

G G

TEST CONN.

91 M

2 2

TEST DRAIN G

TO NORMAL SW DISCH. HDR.

(M16)

B F.C.

F.C.

CAR-2165-G-105 CAR-2165-G-048 CAR-2165-G-041 FLOW DIAGRAM RAD MONITOR WATER SYSTEMS SHEET 2 FLOW DIAGRAM-CIRCULATING & SERVICE FLOW DIAGRAM LEGEND REFERENCE DRAWINGS:

LINE NO. D 7SW1-690-1 7SW1-692-1 7SW1-691-1 7SW1-689-1 1B-NNS 1A-NNS LINE NO. C CHILLER CVCS RELIEF VALVE TAB SUPPLY RETURN LEGEND (A9)

FROM F.C.

M M

M M

M M

M 2*"

2*"

2*"

2*"

2*"

2*"

2*"

2*"

2*"

2*"

2*"

2*"

2*"

2*"

2*"

2*"

2*"

2*"

2*"

2*"

2*"

2*"

2*"

2*"

7SW-V1050-1 3SW-N1086SA-1 3SW-N1087SA-1 3SW-B7SA-1 3SW-N1088SB-1 3SW-N1089SB-1 V

SEE TAB.

(H19)(TYP) 3SW-V475SA-1 CONTINUATION OF TABLE FROM (N4)

TABLE CONTINUES AT (N6) 1B-SB SUCT.

1X-SAB SUCT.

(REF) 3SW-V311SA-1 3SW-N765SB-1 3SW-V515SA-1 3SW-N764SB-1 3SW-N762SA-1 3SW-N763SA-1 48X30 RED.

(TYP)

F.C.

(C14)

S I

TO AIR COMPRESSORS

& AFTERCOOLERS 5-G-048(B1)

RAB TURB. BLDG.

3 (I5)

(I2)

(L9)

S (NOTE 1)

DET. 1 (TYP)

DET.1 (TYP)

(H16,J16)

V F

(TYP) 3SW-V312SB-1 3SW-V518SB-1 3SW-V517SA-1 3SW-V267SB-1 3SW-V266SA-1 3SW-V238SB-1 3SW-V237SA-1 7SW-V52-1 7SW-V51-1 7SW1* - 1727-1 7SW1* - 1727-1 7SW1* - 1727-1 3SW-V1056SA-1 2SW-V408SA-1 2SW-V408SA-1 2SW-V408SA-1 2SW-V408SA-1 2SW-V408SA-1 2SW-V408SA-1 2SW-V408SA-1 2SW-V408SA-1 3SW-V205SB-1 3SW-V1055SB-1 3SW30-97SB-1 FE 9101 B

PX PX PX PX FE 9275 D

S TE 9275 D

S PX PX TE 9276 A

TE 9276 B

TE 9276 C

PI 9111 A

S PT 9101 B

S PDS 9101 B

SB PI 9103 B

S PI 9103 A

S PDS 9101 A

SA PT 9101 A

LS 9101 A1 S

LS 9101 A2 S

LS 9101 B2 S

LS 9101 B1 S

PI 9102 A

S PX PX TE 7040 A

S FE 7050 A S FE 9101 A S FT 9101 A

TE 9102 B S TE 9102 A S FT 9101 B

S PI 9102 B

S TE 7050 A

S FT 9205 A

SA FE 9205 A

S FT 7050 A

SA PDT 7040 A

S TW 9205 A

S FT 9205 B

SB FT 9275 A

SB FE 9275 A

S TE 9275 A

S FT 9275 D

SB FT 9275 B

SA FE 9275 B S TE 9275 B

S TI 9230 C

S TI 9230 B

S TI 9230 A

S PT 9112 A

S FT 9275 C

SA FE 9275 C

S TE 9275 C

S FE 9112 A S FT 9112 A

SA PX PX PI 9111 B

S TW 9205 B

S PX PDT 7040 B

S FE 7050 B

S FT 7050 B

SB TE 7050 B

S PX TE 7040 B

S FE 9205 B

S TI 9202 B

TI 9202 A

PT 9112 B

S FT 9112 B

S FE 9112 B

E 7SW1* - 1727-1 7SW1* - 1727-1 7SW1* - 1727-1 7SW1* - 1727-1 7SW1* - 1727-1 7SW1* - 1727-1 7SW1* - 1727-1 7SW1* - 1727-1 7SW1* - 1727-1 7SW1* - 1727-1 7SW1* - 1727-1 3SW-V1056SA-1 3SW-V1056SA-1 3SW-V1056SA-1 3SW-V1056SA-1 3SW-V1056SA-1 3SW-V416SA-1 3SW-V417SB-1 FE 9276 1C-SAB 1C-SAB PX PX PX PX 1A-SA 1A-SA PX PX PX PX 1B-SB 1B-SB FT 9276 PX PX PX PX 2SW-V408SA-1 2SW-V408SA-1 3SW1-284SB-1 2SW12-280SN-1 7SW6-310-1 7SW6-310-1 3SW14-47SB-1 3SW1-562SB-1 7SW-B94-1 7SW-B94-1 7SW-B113-1 7SW1* - 1727-1 7SW1* - 1727-1 7SW1* - 1727-1 7SW1* - 1727-1 3SW-V532SA-1 3SW-V460SB-1 2SW1-58SA-1 3SWf-435SB-1 3SWf-436SB-1 3SWf-436SB-1 3SW1-443SB-1 3SW16-7SB-1 7SW1*-1728-1 7SW1*-1728-1 3SW1-565SB-1 3SW1-274SB-1 3SW-B69SB-1 3SW4-326SA-1 7SW4-325-1 3SW30-146SB-1 7SW1-1687-1 7SW1* - 1727-1 3SWf-433SA-1 7SW-B400-1 7SW-B111-1 7SW-B97-1 7SW-B95-1 7SW-B93-1 7SW-B96-1 7SW-B94-1 7SW-B92-1 7SW-B113-1 2SW-B52SB-1 2SW-B51SB-1 2SW-B88SAB-1 7SW-B112-1 2SW-B89SA-1 2SW-B90SB-1 3SW-B9SB-1 3SW-B105SA-1 3SW-B106SB-1 3SW-B3SA-1 3SW-B4SB-1 3SW-B2SB-1 7SW-B91-1 3SW-B87SA-1 3SW-B6SB-1 3SW-B5SA-1 3SW-B82SA-1 3SW-B25SA-1 3SW-B17SA-1 3SW-B18SA-1 3SW-B103SA-1 3SW-B83SA-1 3SW-B70SA-1 3SW-B71SA-1 3SW-B72SB-1 3SW-B73SB-1 3SW-B76SB-1 3SW-B64SA-1 3SW-B1SA-1 2SW-B45SA-1 3SW-B23SA-1 3SW-B21SA-1 2SW-B46SA-1 2SW-B47SA-1 2SW-B48SB-1 2SW-B49SA-1 2SW-B50SB-1 3SW-B65SB-1 3SW-B84SB-1 3SW-B104SB-1 3SW-B85SB-1 3SW-B86SB-1 3SW-B24SB-1 3SW-B26SB-1 7SW-B98-1 3SW-B67SA-1 3SW-B66SA-1 3SW-B13SB-1 3SW-B14SB-1 3SW-B15SA-1 3SW-B16SB-1 3SW-V698SB-1 3SW-V699SA-1 3SW-V519SA-1 7SW-V1026-1 3SW-V700SA-1 3SW-V701SB-1 3SW-V512SA-1 3SW-V471SB-1 2SW-V463SN-1 3SW-V513SB-1 3SW-V514SB-1 3SW-V511SA-1 7SW-V215-2 3SW-V13SA-1 3SW-V14SA-1 7SW-V761-1 3SW-V481SA-1 3SW-V480SB-1 3SW-V1058SAB-1 3SW-V1056SA-1 3SW-V1057SB-1 3SW-V460SB-1 3SW-V416SA-1 3SW-V459SA-1 3SW-V458SA-1 3SW-V1SA-1 3SW-V415SA-1 3SW-V484SA-1 3SW-V23SB-1 3SW-V465SA-1 3SW-V464SA-1 3SW-V412SA-1 3SW-V22SA-1 3SW-V21SA-1 2SW-V409SA-1 2SW-V408SA-1 3SW-V414SB-1 3SW-V466SB-1 3SW-V214SB-1 3SW-V417SB-1 3SW-V473SA-1 3SW-V113SB-1 3SW-V112SB-1 3SW-V265SA-1 3SW-V668SA-1 2SW-V142SN-1 3SW-V368SB-1 3SW-V367SA-1 3SW-V369SN-1 7SW-V664-1 3SW-V39SA-1 3SW-V41SB-1 3SW-V728SA-1 3SW-V727SB-1 3SW-V4SB-1 3SW-V2SA-1 7SW-V482-1 3SW-V729SA-1 3SW-V364SA-1 3SW-V363SA-1 3SW-V365SB-1 3SW-V366SB-1 3SW-V528SA-1 3SW-V529SB-1 3SW-V533SB-1 3SW-V535SB-1 3SW-V534SA-1 3SW-V530SA-1 3SW-V531SB-1 3SW-V108SA-1 3SW-V538SB-1 3SW-V539SA-1 3SW-V115SB-1 3SW-V536SB-1 3SW-V537SA-1 3SW-V730SB-1 2SW-R1SA-1 3SW-R8SA-1 2SW-R2SB-1 3SW-R5SB-1 3SW-R6SB-1 3SW-R7SB-1 3SW-R9SB-1 7SW1* - 1727-1 7SW1* - 1727-1 3SW3-1493SB-1 3SW3-1494SA-1 7SW3-1495-1 7SW3-1496-1 3SW1-379SA-1 3SW1*-295SA-1 7SW1-551-1 7SW12-281-1 2SW12-280SN-1 7SW1-1598-1 7SW12-278-1 7SW6-289-1 7SW6-315-1 7SW8-288-1 7SW6-310-1 3SW1-286SB-1 3SW14-47SB-1 3SW1-424SB-1 3SW1-562SB-1 7SW12-328-1 2SW1-538SN-1 2SW12-330SN-1 7SW12-329-1 7SW8-334-1 7SW6-346-1 7SW6-347-1 7SW6-333-1 3SW10- 297SB-1 3SW10- 54SB-1 2SW8-306SB-1 2SW10- 50SB-1 2SW1-415SB-1 2SW8-305SB-1 2SW10- 55SB-1 2SW1-414SB-1 7SW3-149-1 7SW3-646-1 3SW3-148SA-1 3SW3-644SA-1 3SW1-641SA-1 3SW1-640SA-1 3SW*-1578SA-1 3SW* - 1577SA-1 3SW1-279SB-1 3SW1-643SB-1 3SW1-642SB-1 3SW*-1580SB-1 3SW* - 1579SB-1 3SW3-645SB-1 3SW3-152SB-1 7SW3-153-1 7SW3-647-1 3SW3-150SB-1 7SW3-647-1 3SW4-342SB-1 3SW30- 2SA-1 3SW6-750SB-1 3SW30- 5SB-1 3SW1-101SA-1 3SW1-103SB-1 7SC1 1& 2 7SW3-753-1& 2 3SW6-749SA-1 3SW8-751SN-1&2 3SW6-749SA-2 3SW10-752SN-1&2 3SW30-3SA-1 3SW30-6SB-1 7SW1-1469-1&2 7SW2*-1465-1 7SW1-573-1 3SW30- 10SA-1 3SW36-316SN-1 3SW1-447SN-1 7SW36 1 7SW6-1646-1 7SW1* - 1727-1 7SW1-196-2 3SW30-11SB-1 3SW1-135SA-1 7SW12-328-1 7SW2-1530- 1 7SW1-1698-1 3SW3-1493SB-1 3SW1-1527SB-1 7SW1-1699-1 7SW2-1528-1 8FP3-113-1 3SW20-8SA-1 3SW3-572SA-1 3SW12-83SA-1 7SW2*-1400-1&2 3SW30-6SB-1 3SW4-29SA-1 3SW1-172SB-1 3SW1-1529SA-1 3SW1-158SA-1 3SW1-160SB-1 3SW1-136SB-1 3SW3-571SB-1 8FP3-112-1 3SW1-271SA-1 3SW1-192SA-1 3SW24-66SA-1 3SW3-1494SA-1 3SW1-130SA-1 3SW1-114SA-1 7SW*-1650-1 3SW1-139SA-1 3SW3-1500SA-1 3SW24-67SA-1 3SW1-1533SA-1 7SW2-1534-1 3SW1-155SA-1 3SW1*-388SA-1 3SW1*-292SA-1 3SW1*-167SA-1 3SW12-84SA-1 3SW10-68SA-1 3SW1-575SA-1 3SW14-26SA-1 3SW1*-168SB-1 3SW1*-291SB-1 3SW1*-387SB-1 3SW30-25SA-1 3SW14-343SA-1 3SW1*-169SA-1 3SW1*-389SB-1 3SW1*-296SB-1 3SW6-82SA-1 3SW1-1702SA-1 3SW1-380SA-1 3SW1-1704SAB-1 3SW8-338SB-1 3SW1-381SB-1 3SW1-382SB-1 3SW8-81SAB-1 3SW6-80SB-1 3SW1-1703SB-1 3SW1-514SB-1 3SW1-513SA-1 3SW1-445SA-1 3SW1-444SA-1 3SW1-290SA-1 7SW1-196-1 3SW1-142SA-1 3SW1-500SA-1 3SW12-410SA-1 3SW14-28SA-1 3SW1-416SA-1 3SW14-39SA-1 3SW1-512SA-1 2SW8-299SA-1 2SW10- 32SA-1 3SW1-420SA-1 3SW10-31SA-1 3SW10-33SA-1 3SW1-421SA-1 3SW1-285SA-1 3SW14-28SA-1 8FP3-529-1 3SW4-1696SA-1 3SW1-283SA-1 3SW14-27SA-1 2SW8-300SA-1 2SW10- 34SA-1 2SW1-413SA-1 2SW1-412SA-1 3SW10-36SA-1 2SW10-35SA-1 2SW8-301SA-1 2SW1-58SA-1 2SW1-60SB-1 2SW8-302SB-1 2SW10-51SB-1 7SW1-1693-1 3SW1-108SA-1 3SW1-422SB-1 3SW1-109SB-1 7SW3-1497-1 7SW3-1498-1 3SW3-1500SA-1 3SW3-1499SB-1 3SW1*-387SB-1 3SWf-435SB-1 3SW1-539SA-1 3SW1*-167SA-1 3SW1-441SA-1 3SW1*-167SA-1 3SWf-552SB-1 3SW1*-291SB-1 3SW1-540SA-1 3SW10-38SA-1 3SW1*-168SB-1 3SWf-436SB-1 3SW1*-292SA-1 3SW1-541SB-1 3SW1-442SA-1 3SW1*-292SA-1 3SW10-52SB-1 2SW10-37SA-1 2SW8-303SA-1 2SW1-62SA-1 2SW1-64SB-1 2SW8-304SB-1 2SW10-56SB-1 3SW1-110SA-1 3SW1-111SB-1 3SW1-423SB-1 3SW10-57SB-1 3SW14-345SB-1 3SW1*-168SB-1 3SW1*-388SA-1 3SW1* - 390SA-1 3SW1-446SB-1 3SW12-85SB-1 3SW10-74SB-1 3SW8-87SA-1 3SW1*-170SB-1 3SW1-1531SB-1 3SW18-22SB-1 7SW1-1701-1 7SW2-1532-1 3SW3-1499SB-1 3SW1-124SB-1 3SW12-86SB-1 3SW1-269SB-1 3SW2-166SB-1 3SW14-53SB-1 8FP4-512-1 3SW4-1697SB-1 3SW14-46SB-1 3SW12-411SB-1 3SW1-143SB-1 3SW14-47SB-1 3SW1-261SB-1 3SW4-48SB-1 3SW1-564SA-1 3SW1-432SB-1 7SW1-196-1 3SW1-265SB-1 3SW1-576SB-1 3SW1-563SB-1 3SW14-45SB-1 3SW4-91SB-1 3SW4-89SA-1 3SW24-72SB-1 3SW3/4-434SB-1 3SW1-140SB-1 7SWf-550-1 3SW1-141SB-1 3SW1-116SB-1 3SW1-123SB-1 3SW24-73SB-1 7SW36-307-1 7SW1*-1728-1 7SW12-281-1 7SW2*-1468-1&2 7SW1-1463-1&2 3SW36-96SN-1 3SW30-97SB-1 3SW30- 146SB-1 3SW30-25SA-1 3SW1-282SA-1 3SW1-275SA-1 3SW8-87SA-1 3SW8-165SB-1 7SW4-556-1 7SW4-94-1 7SW4-92-1 3SW1-566SA-1 3SW30-99SA-1 3SW8-122SB-1 3SW1-102SB-1 3SW4-327SB-1 3SW30-146SB-1 3SW30- 25SA-1 3SW1-268SB-1 7SW4 1 7SWf-567-1 7SW1-1687-1 7SWf - 568-1 7SW1-1688-1 7SW1-1700-1 7SW1-577-1 7SW1'-574-1 7SWf-549-1 7SW1-448-1 3SW*-1729SA-1 3SW*-1731SB-1 3SW*-1730SA-1 3SW*-1732SB-1 E

S S

C E

F D

G 2

2 2

7SW1-1694-1 3SW-H3SB-1 3SW-H2SA-1 7SW-V477-1 7SW-V476-1 3SW-V485SB-1 NOTE 4 NOTE 4 NOTE 4 NOTE 4 NOTE 5 (NOTE 5)

(NOTE 5)

CS SS 3SW-V1112SA-1 3SW3-173SA-1 3SW3-1751SA-1 SS CS SS CS CS SS 3SW-V1113SB-1 3SW3-1752SB-1 PX 7SW-V1049-1 3.

M (NOTE 3)

(NOTE 3)

M M

(NOTE 3)

(NOTE 3)

M SEE NOTE 6 SEE NOTE 6 7.

(SEE NOTE 7) f " PLUG RAB TGB TGB 1" PLUG 2SW-R18SN-1 2SWf-1757SN-1 CS SS (SEE NOTE 7) f " PLUG APPROVED SEE NOTE 6 SEE NOTE 6 SEE NOTE 6 3SW-B8SA-1 SEE NOTE 6 7SW2*-1400-1&2 7SW4-93-1 3

3SW4-1762SB-1 NOTE 8 3

NOTE 8 3SW4-1761SA-1 3SW-V1117SA-1 3

3SW4-1764SB-1 3SW-V1119SB-1 8

NOTE 3

NOTE 8 3SW-V1118SA-1 3SW4-1763SA-1 3SW-V1116SB-1 SEE NOTE 6 SEE NOTE 6 SEE NOTE 6 CS SS CS CS CS SS CS SS 2SW-R3SA-1 CS 7SW-V781-1 CS SS CS 2

CS SS CS CS SS CS SS CSSS CS SS 9277 FE 9278 FE NOTE 2 NOTE 2 9282 FE NOTE 2 9281 FE NOTE 2 CS SS SS CS SS CS CS SS PLUGGED 2" SOL, PLUGGED f" SOL, PLUGGED 2" SOL, PLUGGED f" SOL, PLUGGED 2" SOL, PLUGGED 1" SOL, PLUGGED f" SOL, PLUGGED f" SOL, PLUGGED f" SOL, PLUGGED 2" SOL, PLUGGED f" SOL, PLUGGED 2" SOL, PLUGGED f" SOL, 9279 FE NOTE 2 9280 FE NOTE 2 SEE NOTE 6 3SW-V1132SB-1 3SW1-1776SB-1 CS SS 3SW1-393SA-1 3SW-H388SA-1 3SW1-394SA-1 3SW1-395SA-1 3SW-H389SA-1 3SW-H390SA-1 3SW1-392SA-1 3SW1-115SA-1 3SW1-391SA-1 3SW-H387SA-1 3SW-H109SA-1 7SWf-1786-1 7SWf-1787-1 3SW-H386SA-1 NOTE 10 NOTE 10 NOTE 10 SEE NOTE 11 3SW4-1792SA-1 3SW1-398SB-1 3SW-H393SB-1 3SW1-399SB-1 3SW1-400SB-1 3SW-H394SB-1 3SW-H395SB-1 3SW1-397SB-1 3SW1-396SB-1 3SW-H392SB-1 3SW-H391SB-1 3SW-H117SB-1 3SW1-117SB-1 INST. OR DRAIN TEST VENT, TEST CONN 7SW-H12-1 7SW1-196-1 7SW1-1793-1 STEEL APPLICATIONS.

TO BE USED FOR STAINLESS THE VALVE AND LINE ARE SS CS CS CS SS CS SS CS CS SS CS CS SS CS CS SS CS CS SS CS CS CS SS CS CS SS CS CS SS CS 3SW-B68SB-1 CS SS CS CS SS CS CS SS CS CS SS CS SS 3SW-J4SB-1 3SW-H116SB-1 3SW-H104SB-1 2SW-H410SB-1 3SW-H26SB-1 3SW-H251SB-1 3SW-H252SB-1 3SW-H155SB-1 7SW-H141-1 7SW-H141-1 3SW-H230SB-1 3SW-H239SB-1 3SW-H33SB-1 3SW-H212SB-1 3SW-H472SB-1 3SW-H68SB-1 3SW-H69SB-1 3SW-H96SB-1 3SW-H97SB-1 3SW-H98SB-1 3SW-H99SB-1 3SW-H270SB-1 3SW-H474SB-1 3SW-H216SB-1 7SW-V215-1 3SW-H211SB-1 SS CS CS SS CS SS CS SS CS SS CS SS SS CS SS CS SS CS SS CS CS SS CS SS 3SW-B20SB-1 CS SS SS CS SS CS SS CS SS CS CS SS CS SS SS CS SS SS CS SEE NOTE 6 SEE NOTE 6 SEE NOTE 6 SEE NOTE 6 SEE NOTE 6 SEE NOTE 6 SEE NOTE 6 SEE NOTE 6 SEE NOTE 6 SEE NOTE 6 SEE NOTE 6 SEE NOTE 6 SEE NOTE 6 SEE NOTE 6 SEE NOTE 6 SEE NOTE 6 SEE NOTE 6 SEE NOTE 6 3SW8-88SA-1 3SW8-88SA-1 (NOTE 12) 3SW-H20SA-1 3SW-H19SA-1 7SW-H667-1&2 CS SS CS SS 3SW-H250SA-1 3SW-H249SA-1 3SW-H225SA-1 3SW-H254SA-1 3SW-H253SA-1 3SW-H55SA-1 CS SS 3SW-H56SA-1 CS SS CS SS CS SS CS SS CS SS CS SS CS SS CS SS CS SS 3SW-H240SB-1 7SW-H667-1&2 3

2 3SW-H241SA-1 3SW-H242SA-1 CS SS CS SS SS CS CS SS SS CS 3SW-H245SB-1 CS SS 3SW-H246SB-1 SS CS 3SW-H224SB-1 CS SS SS CS 2SW-H411SB-1 CS SS 3SW-H268SB-1 CS SS 2SW-H490SB-1 3SW-B77SB-1 (NOTE 6) 3SW-B19SB-1 3SW-B22SB-1 (NOTE 6)

SS CS PLUGGED f" SOL, PLUGGED f" SOL, (SEE NOTE 7) f" PLUG (SEE NOTE 7) f " PLUG 3SW-H25SB-1 DUKE ENERGY ELECTRONICALLY SIGNED L.O.

L.O.

L.O.

L.O.

L.C.

L.C.

L.C.

L.C.

L.C.

L.C.

ELECTRONICALLY SIGNED REMOVE BEFORE START-UP(H15)

4. 3SW-V532SA-1 AND 3SW-V-534SA-1 CLOSED WHEN CSIP 1C-SAB IS POWERED FROM 'B' IS POWERED FROM 'A' ELECTRICAL BUS.

3SW-V535SB-1 CLOSED WHEN CSIP 1C-SAB ELECTRICAL BUS. 3SW-V533SB-1 AND

1. TEMPORARY STRAINER FOR INITIAL FLUSHING,
6. VALVE MATERIAL IS STAINLESS STEEL.

OF SUPPLY/RETURN VALVES MAY REMAIN OPEN

8. 4" SYSTEM DRAIN PIPING IS CARBON STEEL.
10. EXPANSION JOINTS ARE STAINLESS STEEL.

FOR PASS AND CVCS CHILLERS.

THREADED PLUG; REF. EC 74408 BRANCH CONNECTION; PIPE CAP INCLUDES *"

BY FULL-PENETRATION WELD BUT IS NOT A 4" 3SW1-267SA-1; LINE ATTACHED TO 30" HEADER

11. LINE ENCAPSULATES REMOVED DRAIN LINE
5. VALVE LINE-UP MAY VARY. ONLY ONE TRAIN SEE DETAIL ON DRAWING 5-G-0102.

PENETRATION LOCATED AT A-245 C43-W5.

12. LINE REDUCES TO 3.5" PIPE THROUGH AND IS USED MANUALLY ONLY.

VALVE MOTOR HAS NO POWER CABLES TO IT LINE (32 CONNS. PER COOLER) 4 CONNS. PER EACH INLET/OUTLET PLUGGED CONNECTION TYPICAL OF MEASUREMENTS.

TO THE PIPING FOR OBTAINING FLOW RATE

2. CONTROLOTRON TRANSDUCERS ARE MOUNTED CHILLERS (EC90655).

TERM SHUTDOWN BOUNDARY FOR THE CVCS MOTIVE AIR REMOVED AS PART OF THE LONG

& V267SB-1 ARE PERMANENTLY SHUT WITH

13. VALVES 3SW-V237SA-1, -V238SB-1, -V266SA-1, CIRCULATING & SERVICE WATER SYSTEMS FLOW DIAGRAM SHEET 1-UNIT 1 G-047 CAR-2165 (NOTE 13)

(NOTE 13)

(NOTE 13)

(NOTE 13) 3 3SW-V1149SA-1 3SW-H13SA-1 10x12 CONN FLEX V

7SW10-1808-1 3SW10-1802SA-1 3SW1-1803SA-1 SUPPLY (G2)

TO ESW CS SS 3SW10-1806SA-1 10x12 7SW10-1809-1 3SW10-1804SB-1 3SW1-1805SB-1 3SW-V1150SB-1 CS SS V

3SW-H14SB-1 CONN FLEX 3

3SW10-1807SB-1 CONN (A2)

FROM FLEX SS CS 3SW4-341SA-1 3SW4-1810SA-1 3SW1-133SA-1 H223SA-1 3SW-CS SS CS SS 3SW-V1054SA-1 SS CS CS SS SS CS CS SS 3SW-H213SA-1 CS SS 3SW-H243SA-1 3SW-H244SA-1 CS SS 3SW-H272SN-1 SS CS CS SS 3SW-H450SA-1 SS CS 3SW-H31SA-1 CS SS CS SS 3SW-H413SA-1 3SW-H94SA-1 3SW-H95SA-1 3SW-H88SA-1 3SW-H89SA-1 SS CS SS CS SS CS CS SS 3SW1-126SA-1 3SW8-128SA-1 SEE NOTE 6 SEE NOTE 6 3SW-B74SA-1 3SW-B75SA-1 SEE NOTE 6 NOTE 6 SEE NOTE 6 2SW-R4SB-1 89 ELECTRONICALLY SIGNED INCORPORATED: EC 404085 (C12) 90 CS SS CS 3SW-V520SB-1 3SW-V516SB-1 SS CS CSSS SS CS CS SS SS CS EC 299131 (F14,F16)

INCORPORATED: EC 293477 (D1,E2) 91 (NOTE 6)

(NOTE 6)

(NOTE 6)

(NOTE 6)

(NOTE 6)

(NOTE 6)

(NOTE 6)

INCORPORATED: EC406320(C8,D13,D14,I10,J10)

7SW4-1734-1 7SW3-1496-1 ESW SUPPLY PX 7SW2-182-1 V

FD 7SW6-548-1 7SW4-557-1 PX PX PX PX V

7SW3-542-1 FD 7SW-V285-1 7SW-V286-1 1B-NNS 1A-NNS FD FD 7SW-V288-1 7SW6-545-1 7SW4-560-1 V

7SW4-336-1 V

7SW2-356-1 7SW1*-205-1 PX PX 7SW-V1111-1 7SW1-1736-1 PX 7SW1*-358-1 7MP-V7-1 7MP1-17-1 7MP36-4-1 PX 7SW10- 547-1 BF 7SW-V135-1 7SW6-222-1 FD FD FD 7SW-M4-1 F.O.

7SW-V167-1 7SW-V166-1 7SW-V703-1 7SW3-1497-1 7SW8-344-1 7SW6-545-1 L.O.

7SW3-543-1 V

7SW-V136-1 7SW1-448-1 7SWf-549-1 7SW1-196-1 7SW1-254-1 7CW1-14-1 7SW-R13-1 TO FLOOR DRAIN 7SW-V1105-1 FD V

7SW-B28-1 7SW-V148-1 7SW-V150-1 7SW2-211-1 7SW20-324-1 7SW3-204-1 7SW1-1502-1 7SW2-357-1 7SW4-1735-1 7SW-V1091-1 7SW1-207-1 7SW1-209-1 V

FD FD 7SW-M5-1 7SW-B27-1 7SW8-234-1 7SW16-240-1 7SW8-236-1 7SW-V218-1 7SW12-241-1 PX FD PX PX FD 7SW8-238-1 7SW-V180-1 FD PX 7SW-V181-1 PX 7SW8-239-1 FD FD FD 7SW-B78-1 7SW-B79-1 7SW-B80-1 PX FD 7SW-B81-1 V

PX FD PX PX PX PX FD FD 7SW2*-227-1 7SW2*-225-1 7SW-V171-1 7SW-V170-1 PX 7SW2*-221-1 FD FD 7SW2*-228-1 7SW-V175-1 7SW-V174-1 7SW6-223-1 7SW-V217-1 7MP-V8-1 7MP1-126-1 7MP36-7-1 7MP-V99-1 7MP-83-1 7MP 1 M

M 7MP10-130-1 FC 7MP-L1-1 7MP10- 131-1 PX FD PX PX 7SW-V147-1 7SW-V149-1 V

7SW-V258-1 FD PX 7SW1-1599-1 7SW-V156-1 V

7SW3-199-1 7SW1-206-1 7SW2-212-1 7SW1-213-1 7SW-V157-1 V

V V

f" PX PX f"

f" f"

PX 7SW1-216-1 FD 7SW1-362-1 7SW-V159-1 7SW-V611-1 FD 7SW-V612-1 7SW1-361-1 7SW1*-363-1 7SW4-242-1 7SW-V176-1 7SW-V177-1 7SW-V782-1 7SW4-248-1 7SW12-230-1 PX FD V

PX 7SW3-245-1 7SW-V183-1 7SW-V182-1 PX PX FD PX PX FD FD 7SW-V186-1 7SW-M6-1 F.O.

7SW-V192-1 FD F.O.

7SW-V187-1 PX BF BF 7SW-V188-1 7SW-M7-1 FD 7SW-V189-1 7SW-V193-1 7SW2-247-1 7SW3-246-1 7SW-V1052-1 7SW1*-1747-1 FD FD FD F.O.

7SW-V164-1 7SW-V165-1 7SW-M3-1 7SW-V158-1 7SW1-214-1 7SW2-217-1 7SW2-200- 1 7SW2-202-1 7SW1-359-1 7SW1-360- 1 7SW-V609-1 7SW-V610-1 7SW1-215-1 7SW2*-226-1 FD 7SW2*-219-1 7SW2*-220-1 7SW2*-224-1 7SW-V173-1 7SW6-218-1 7SW20-191-1 FD 7SW-B54-1 7SW-V172-1 7SW3-1625-1 7SW-V780-1 PX 7SW3-1626-1 7SW2-1612-1 L.O.

7SW2-1624-1 7SW4-243-1 7SW1*-1621-1 7SW-V797-1 7SW2-244-1 FD 7SW*-1601-1 7SW1-1602-1 7SW-V783-1 PX 7SW24-544-1& 2 W.P.B.

YARD 7SW24-546-1& 2 7SW-B44-1 7SW24-546-1 7SW24-554-1 7SW36-307-1 FX FX G

PX 7CW1 1 FD FX 7CW-H1-1 7CW-B4-1 7CW-J4-1 7CW6 1 (TYP.4)

FD 4"

7CW-12-1 7CW-V1-1 7CW2-40-1 7CW-V22-1 7CW2-39-1 7CW2-41-1 7CW-V24-1 7CW-B5-1 BY MECH 1x*RED TUBING BY I&C 7CW-J8-1 120" R.C. PIPE FD 7CW-J5-1 PX 4"

7CW-H1-1 1"

7CW-V27-1 7CW2-44-1 7CW2-42-1 7CW-25-1 7CW-V19-1 7CW-J9-1 120" R.C. PIPE 7CA1-9-1 7CW2-43-1 7CW-V26-1 7CW1-38-1 7CW102-18-1 7CW-V2-1 7CW102-17-1 7CW102-16-1 7CA*-21-1 7CW72-1-1 7CW-J1-1 78 PX M

78 7CW-J2-1 7CW72-2-1 7CW-B1-1 M

7CW-B2-1 PX M

7CW72-3-1 7CW-J3-1 78 PX 7CW-B3-1 7CW4-13-1 7SW2-767-1 7SW48-313-1 M

7SW-B37-1 7SW48-313-1 7SW1-321-1 7SW2-323-1 7SW-V510-1 7SW-H1-1 7SW-S23-1 7SW-V206-1 7SW2-1663-1 7SW-V202-1 7SW-V1045-1 7SW-B57-1 7SW-V203-1 7SW-B56-1 7SW48-348-1 7SW-V558-1 7SW2-754-1 7SW2-1649-1 7SW8-322-2 7SW-G7-1&2 7SW36 1 7SW24-13-1 7SW8-322-1 G

7SW-B43-1 7SW48-313-1 7SW42-12-1 7SW2-754-2 7SW2-323-2 7SW8-746-1&2 7SW48-312-1 7SW-B38-1 M

7SW2-777-1 7SW24 1& 2 7SWf - 1664-1 W.P.B.

YARD 7SW24-4-2 7SW24-4-1 7CWf-36-1 7CW-V16-1 7CW-B7-1 7CW-H1-1 7CW-J6-1 7CW-J7-1 7CW-B6-1 7CW-V15-1 7CW-H1-1 FD FD FD 4"

4" 7CWf 1 1*"(TYP.)

1" BY I&C PX PX 7CW-V40-1 7CW-V42-1 7CW1-55-1 7CW1-53-1 7CW-V41-1 7CW-V43-1 7CW1-54-1 7CW1-56-1 7CW-J10-1 7CW-J11-1 7CW108-9-1 7CW108 1 7SW42-308-1 7SW-B53-1 7SW-V747-1 7SW-V1000-1 fx* RED.

BY I& C V

TB 7SWf - 1733-1 7SW42-1-1 7SW42-309-1&2 7SW-V748-1 7SWf-1551-1 7SW12-262-1 FD V

V V

FD PX V

7SW* - 351-1 7SW-V196-1 7SW1-256-1 7SW-V197-1 7SW-V766-1 7SW1-255-1 7SW*-756-1 7SW1-196-1 7SW24-335-1 7SW-V1038-1 120"RC. PIPE 7SW-V215-1 7SW-B40- 1 120"RC. PIPE 7SW1*-1490-1 7SW16-231-1 7SW2-252-1 7SW1-1576-1 7SW1* - 755-1 7SW1-253-1 7SW-V559-1 7SW-V195-1 7SW-V560- 1 7SW-V194-1 7SW-X11-1 7SW-X10- 1 7SW-X12-1 7SW*-350-1 7SW2-257-1 7SW-V168-1 7SW-V167-1 7SW1-1589-1 7SW6-264-1 7SW2-353-1 7SW2-352-1 7SW24 1 7SW1*-1610-1 7SW-V776-1 7SW1*-1622-1 7SW2-1627-1 7SW3-1628-1 7SW6-264-1 7SW1* - 1746-1 7SW-V1104-1 7SW-V1108-1 7SW1-1737-1 7SW2-210-1 7SW-V1093-1 7SW20-324-1 SEE NOTE 3 7CW-V23-1 NC BY EBASCO BASIN 7SW4-559-1 7SW1-1501-1 (F7) 3" 3"

3" 3"

7SW-V702-1 L.O.

7SW-V1090-1 7SW3-1691-1 7SW3-1690-1 REFERENCE DRAWINGS CAR-2165-G-047 NOTES:

2. (*) INDICATES SUPPLIED BY MFG.
3. LEVEL SWITCH MOUNTED IN THE IMMEDIATE VICINITY
4. ALL CAUSTIC PIPING TO BE HEAT TRACED UNLESS OTHERWISE NOTED.

LEGEND SUPPLY RETURN COOLING TOWER 7CW-V3-1 DETAIL "1" REV DESCRIPTION TITLE:

NUCLEAR ENGINEERING DEPARTMENT - RALEIGH, N.C.

DWG NO.

SCALE:

PLANT:

NUCLEAR SAFETY RELATED (Q-LIST)

THIS DRAWING HAS BEEN PRODUCED AND IS CONTROLLED ON THE NED CAD/E SYSTEM. ANY REVISIONS TO THIS DOCUMENT SHOULD BE DONE USING THE CAD/E SYSTEM TO ASSURE PROPER CONTROL OF THE ELECTRONIC DRAWING DATABASE.

CAR-2165-HARRIS NUCLEAR PROJECT - UNIT 1 NONE APPR'D M

N G-048 1

2 3

4 5

6 7

8 9

10 11 12 13 14 15 16 17 18 19 1

2 3

4 5

6 7

8 9

10 11 12 13 14 15 16 17 18 19 A

B C

D E

F G

H I

J K

L M

N A

B C

D E

F G

H I

J K

L PARTIAL PX S

7SW-V1051-1 42" B.F.

7SWf-1552-1 1'

1' 1'

1' SEE NOTE 3 7CW108 1 7CW108-5-1 1x* RED 7SW6-189-1 7SW2-203-1 LOC. IN CAR-2165-G-308 TO SECONDARY SAMPLE SYSTEM CPL-2165-G-089S01(F15)

CO CO CO 7SW-H6-1 7SW-H7-1 7SW1-208-1 7SW-H8-1 7SW-H9-1 5-G-047 (B11)

C.W. PUMP DISCHARGE BLOCK 7SW1*-1766-1 7SW1*-186-1 7SW-V1122-1 7SW-V138-1 7SW-V1121-1 7SW-V1123-1 7SW1-1768-1 FD 7SW2-1612-1 7SW1-1770-1 7SW-V1125-1 FD V

FD SS CS 7SW-V1124-1 7SW1-1769-1 SS CS FD V

7SW1-1774-1 FD 7SW1-1767-1 7SW1-1771-1 7SW-V1126-1 7SW1-1772-1 7SW1-1775-1 7SW1-1773-1 7SW-V1127-1 7SW-V1128-1 7SW-V1129-1 TO CIRCULATING WATER INTAKE BAYS 7SW12-745-1&2 BF A2 9296 FI 7SW-V215-1 V

NNS 1B-7SWf-1785-1 6"

7SW-V1137-1 7SW6-1781-1 7SW1*-180-1 7SW4-1780-1 7SW6-1778-1 7SW-V1134-1 PX 7SW-V1135-1 7SW4-1779-1 7SW6-1782-1 7SW-V1136-1 7SW-V1142-1 7SW1-1789-1 EXCH ONLY 1B CVP HT FD 7SWf-1784-1 6"

7SW6-1781-1 7SW-V1143-1 NNS 1A-FD A

9219 TI V

EXCH ONLY 1A/1B CVP HT 7SW1-1788-1 EXCH ONLY 1A CVP HT B

9260 TI A

9260 TI HEAT EXCHANGERS VACUUM PUMPS CONDENSER OIL COOLERS FEED PUMP STEAM GENERATOR COOLERS DEH UNIT TURBINE 4240 TI A

1952 TE B

1952 TE (G17)

CAR-2165-G-308 MAKE-UP WTR PUMP COOLING TOWER A

1960 FE A

1960 FT A3 9296 TI 9286 TI 0951 TCV OIL COOLERS (B8)

PUMPS & HYD COUPL FROM COND BOOSTER PX,PS,FT,FI,CT INST.-AT,PI,PT, (K2)

CAR-2165-G-308 TOWER BLOWDOWN TO COOLING 0950 TCV A

9220 TI A

0950 TI B

0950 TI NNS 1A-NNS 1B-C 0950 TI NNS 1C-COOLERS HYDROGEN D

0950 TI NNS 1D-0940 TI A1 0951 TI A2 0951 TI B1 0951 TI B2 0951 TI VENT (TYP)

OPEN END 1931 LCV NNS 1A-NNS 1B-NNS 1A-NNS 1B-B 9220 TI 4250 TCV A

9212 TI NNS 1A-NNS 1B-1941 TI A

9213 TI B

9213 TI B

9212 TI NNS 1A-NNS 1B-0943 TI A

9223 TI A

0953 TCV B

0953 TCV 1X-NNS COOLER HYDROGEN SIDE 1X-NNS COOLER AIR SIDE A

0953 TI B2 9296 FI B3 9296 TI 9301 FT 9301 FE (N4)

CAR-2165-G- 876 PROCESSING BLDG.

FROM WASTE (M14)

CAR-2165-G- 047 BLDG.S.W.RETURN FROM REACTOR AUX A

3500 REM FLG.

BLIND BY FIELD (TYP.4)

SAMPLE CONN.

1930 AE A

1940 TW A

1940 TE (TYP.4) 7CW-V5-1 9304 FE 1940 LS B

1940 TW BY I&C TUBING B

1940 TE A

1930 PI A

1930 PS 1931 CE B

1930 PI B

1930 PS C

1930 PS C

1930 PI 1930 TE ALARM LEVEL LOW 1931 LE 1931 LS NNS 1C NNS 1B A

9301 PI 9301 FCV 9301 TE 9302 PS (B9)

CAR-2165-G-436 A

9302 PI H

9301 PDS HH 9301 PDS B

9302 PI 9302 PT G-110 S01 (C7)

NNS CAR-2165-EJECTOR 1&2X TO CHLORINE UNITS 1&2 SUMP BACKWASH NSW STRAINER B

9301 PI (B12) 2165-G-436 (B19)

CAR-2165-G- 436 TO CYCLONE SEP.

UNIT 1 CHAMBER UNIT 2 CHAMBER SCREEN STATIONARY GATE SLIDE 9302 LE NNS 1B 9300 LE NNS 1A CONDUIT CONCRETE CAR-2165-G- 047 (L1)

SERVICE WATER REACTOR AUX BLDG CONT. AT (K1)

SERVICE WATER TURB. BUILDING (C19)

CAR-2165-G-436 CYCLONE SEPARATOR 1X-NNS CONDENSER MAIN (TYP.4)

BY FIELD SAMPLE CONN.

(TYP.)

1'"

RED.

fx*

1933 AE A4 1950 TE A4 1950 TW B

1951 PX A

1951 PX A3 1950 TW A3 1950 TE A2 1950 TE A2 1950 TW A1 1950 TW A1 1950 TE B

1951 DPX A

1951 DPX 1950 LS B1 1950 TW B2 1950 TW B3 1950 TW B4 1950 TW B1 1950 TE B2 1950 TE B3 1950 TE B4 1950 TE TUBE CLEANING SYS.

FUTURE CONDENSER SPOOL PIECES FOR B

3500 REM BLDG TURBINE SAMPLE GRAB RETURN WATER SERVICE 9265 FE 9250 TE 9201 AIT 9224 TI NNS 1A-NNS 1B-A1 9223 TI B

9223 TI B1 9223 TI G-089 (C12)

PANEL CAR-2165-FROM SEC. SAMPLING OIL COOLERS TURBINE LUBE PUMP MOTORS CONDENSATE UNIT SEAL OIL HYDROGEN CONT.FROM (J17)

NORM SERV.WTR PUMPS COOLING WTR FROM G-300 SO2 (C5) 1C-NNS CAR-2165-FROM AFTERCOOLER 2165-G-089S01 (E15)

SAMPLE SYSTEM FROM SECONDARY 2165-G-105 (H8) 1BD-3527 FROM REM MONITORING EQUIP FROM SW CHEM.

CONN FOR RETURN 8 PLACES)

SYSTEM (TYP TUBE CLEANING FUTURE COND CONNS FOR 8" BLIND FLG (K9)

CAR-2165-G-486 CAUSTIC STORAGE FROM BULK GATE (L.O.)

SLUICE SYSTEMS SEE 5-G-436)

(FOR SEAL & LUBE WATER CIRCULATING WATER PUMPS COOLING BY CONTRACTOR TOWER PUMP MOTORS HEATER DRAIN NNS 1A CHEM. MONITORING EQUIPMENT CONN. FOR SUPPLY TO SW

& HYDRAULIC COUPLING OIL COOLERS CONDENSATE BOOSTER PUMPS 5-G-105 (C8) 3527 SEE DWG TO REM-1BD-G-300 S02 (C5) 1C-NNS CAR-2165-TO AFTERCOOLER 5-G-047 (A11)

ESW RETURN FLOW DIAGRAM LEGEND INSTRUMENT LIST PIPING LINE LIST VALVE AND SPECIALITY LIST WATER SYSTEMS SHEET 1 FLOW DIAGRAM-CIRCULATING & SERVICES CAR-2165-G-041 CAR-2166-B-432 CAR-1364-B-070 CAR-1364-B-069 CAR-2165-G-088 CAR-2165-G-876 RELIEF VALVES EXCEPT WHERE NOTED OTHERWISE TYPICAL FOR DRAINS, VENTS, INSTRUMENTS & SAFETY SHEET 2 - UNIT 1 CIRCULATING & SERVICE WATER SYSTEMS FLOW DIAGRAM G-048 CAR-2165 CAR-2165-G-089(C12)

TO SEC. SAMPLING PNL.

(N1)

BLDG.CAR-2165-G- 876 TO WASTE PROCESSING FLOW DIAGRAM MISC. SYS PROCESS BLDG. SH 1.

COOLING WTR. SYSTEM FOR WASTE DRAIN PUMPS HEATER STRUCTURES SCREEN WASH SYS.

CTBD, MAKE-UP & INTAKE (H8)

DWG 5-G-105 1MD-3528 SEE FROM REM (E4) 5-G-105 SEE DWG FOR DET.

(C8)

DWG 5-G-105 1MD-3528 SEE TO REM CAR-2165-G-436)

WTR SYSTEM, SEE (FOR SEAL & LUBE WATER PUMPS NORMAL SERVICE VENT PLUGGED LARGE WATER ACCUMULATIONS IN CONDENSER PIT.

OF THE EXPANSION JOINT TO ALARM OPERATOR OF (E4)

SEE 5-G-105 FOR DETAIL (TYP.4) 4"VENT B

0953 TI L.O.

7SW-V779-1 1A-NNS AFTER COOLER AIR COMPRESSOR (C8) 5-G-105 REM 1TV-3534 TO (H8) 5-G-105 REM 1TV-3534 FROM 1B-NNS AFTER COOLER AIR COMPRESSOR (BY VENTOR)

SYSTEM CHEMICAL ADDITION CIRCULATING WATER (BY VENTOR)

SYSTEM CHEMICAL ADDITION CIRCULATING WATER BAYS INTAKE TO NSW (A14)

THIS DWG (D17)

@ C.W. BASIN TO NSW INTAKE

5. VALVE IS STAINLESS STEEL.

PIPING AND VALVE TAG NUMBERS.

INSTRUMENT, DRAINS, VENTS AND RELIEF VALVE

1. SEE TYPICAL DETAILS ON THIS DRAWING FOR NOTE 5 NOTE 5 NOTE 5 7SW-H12-1 7SW1-1793-1 STEEL APPLICATIONS.

TO BE USED FOR STAINLESS THE VALVE AND LINE ARE SS CS CS CS SS CS SS CS CS CS SS CS CS SS CS CS SS CS F.O.

7SW-B55-1 SS CS CS 7SW2-201-1 7SW-V1107-1 7SW-H1092-1 7SW-J15-1 7SW-J16-1 7SW-J13-1 7SW-J14-1 V

10" 7SW-B34-1 7SW-B33-1 7SW12-260-1 FD 10" FD V

FD FD 7SW1-256-1 7SW1-255-1 7SW12-258-1 7SW*-756-1 7SW-B31-1 7SW12-259-1 7SW8-263-1 7SW*-350-1 7SW-B32-1 7SW-B29-1 7SW-V198-1 7SW-M8-1 7SW-B30-1 F.O.

A 4740 TI B

4740 TI A

4750 TI B

4750 TI 4750 TCV 7SW1*-1491-1 7SW10-547-1 FD PX V

PX 0942 TI 7SW3-1795-1 7SW4-1794-1 7SW4-1797-1 7SW3-1796-1 0945 TI FD FD 7SW-V190- 1 0952 TI 7SW4-248-1 UNIT 1A COOLING LEADS GENERATOR UNIT 1B COOLING LEADS GENERATOR 7SW4-251-1 7SW4-1798-1 7SW-V1147-1 0901 FIS 7SW3-728-1 7SW-V1148-1 7SW-V1144-1 FD PX 7SW3-726-1 NOTE 5 NOTE 5 NOTE 5 NOTE 5 NOTE 5 NOTE 5 66 SIGNED ELECTRONICALLY INCORPORATED: EC 86759 (J10,M10,M11) 67 SIGNED ELECTRONICALLY FD FD FD FD FD FD 7SW8-233-1 7SW8-235-1 7SW8-237-1 7SW8-232-1 PX PX PX FD 7SW-V178-1 7SW-V179-1 FD 7SW4-1779-1 7SW1*-183-1 7SW6-1790-1 7SW4-1791-1 FD PX PX B

9219 TI 7SW1-1788-1 FD 7SW1-1789-1 7SW6-1783-1 (C5,D7,E11,F5,H3,J1,K10,M10,M11,N11)

INCORPORATED: EC 92230 CS CS SS CS SS CS SS CS SS CS SS 68 SIGNED ELECTRONICALLY 7SW-V287-1 (B7, L4, L5, M4, M5)

INCORPORATED: EC 93478 69 SIGNED ELECTRONICALLY SS CS 1X-NNS COOLER EXCITER INBOARD 1X-NNS COOLER EXCITER OUTBOARD CS SS SS CS SS CS CS SS CS SS SS CS SS CS (H2,H3,H4,H5)

INCORPORATED: EC 94538 DUKE ENERGY 70 SIGNED ELECTRONICALLY (NOTE 5)

(NOTE 5)

NNS 1B-NNS 1A-PX SS CS CS SS PX PX SS CS CS SS PX PLCS TYP. 4 1xf RED.

EC 94844(I6,I7)

INCORPORATED: EC 94413 (K10,K11,L10-L12) 7SW-X7-1 7SW-X8-1 7SW-X5-1 7SW-X9-1 7SW-X6-1 7SW-X1-1 7SW-X3-1 7SW-X4-1 7SW-X2-1 71 SIGNED ELECTRONICALLY L9,L10)

INCORPORATED: EC 98342 (D10,D11,J2,K8-K10, 72 SIGNED ELECTRONICALLY (NOTE 5)

(NOTE 5)

INCORPORATED: EC 100398 (I8,I9) 73 SIGNED ELECTRONICALLY INCORPORATED: EC 406456 (H7,I3,K9)

1 2

3 4

5 6

7 8

9 10 11 12 13 14 15 16 17 18 19 SPRAY NOZZLE-3CT-X3SAB-I y f 3 C T 2 - 108SAB - 1)

CAR - 2 165 G-050 (TYP.)

A B

c D

E F

G H

I J

L M

N

. -. F a I

I-ILL CONN

~

LOCATE ABOVE MIN, WATER LEVEL I N I D Q

v,

.TO RM ATMOS.

.c-STRAIGHT BRANCH ARRANGEMENT 90 BRANCH ARRANGEMENT TECH. SPEC, 3NI-V128SAB-1 3 N I -Vl27SAB-1 CAR-2165-G-058 T-I D

Q v,

u3 CY I

CY I-o m

o

( 7CT13/4-18-1 )

m

\\

An 3CT1-17SAB-1

\\

f l

\\

S I S HYDROTEST SYS.

CAR-2 165 -G-8 10

~

s E

E

~. 1 )

REFUELING WATER E

c c

E F

c I

i.

L n

r 3CT-V143SAB-1 c

I I

f 4 2CT1-149SA-1

- 2.CT4 - 5 9 SA 15 n r x O

/

1 STORAGE TANK I

470,000 GAL.

i m I

//

I YXI I

I (7SI2-279-1 IX-SAB SC-2 DETAIL 1

[HDR. HAS-I9 STR, BRANCH ARRGTS.

~

AND 15 90 BRANCH ARRGTS.]

3 N

3

\\

WTR 9 S 0 2 I

2CT-V59SAB L.C.

FU N N

E L

l 2CT4-59SA-1

(-3

/---7CT-V9 4-1 L.0.

/

I I

e C H A R G I N G PUMP DISCH CAR-2165-G-804 (MI)

SEE DETAIL 1 (c2)

\\

rl 7

I 3 m

a I a I-o c\\l

?

Y NOTES

1.

OVERIDE TO CLOSE ON T SIGNAL DURING TESTING.

2, TEMPORARY STRAINER FOR INITIAL FLUSHING.

REMOVE BEFORE STARTUP.

3, PUMP STARTS ON CSAS (CONTAINMENT SPRAY ACTUATION SIGNAL) I N CASE OF COINCIDENT LOSS OF OFFSITE POWER PUMP WILL START I N THE SECOND LOAD BLOCK OF THE EMERGENCY GENERATOR.

1, VALVE NORMALLY CLOSED WITH THE CIRCUIT BREAKER LOCKED OPEN TO ENSURE NO POWER TO ACTUATE THE MOTOR OPERATOR ON THE VALVE.

5, DURING TESTING, LOCK CIRCUIT BREAKER OPEN TO KEEP THE VALVE I N CLOSED POSITION.

5. WITH A GIVEN TRAIN I N THE TEST MODE CLOSE THE RESPECTIVE TRAIN VALVES ON r SIGNAL.

7, DRAIN CONNECTION TO REFUELING CAVITY DURING CHECK VALVE TESTING.

3. HEAT TRACING ON THE TANK I S PROVIDED BY MEANS OF HOPPER HEATERS FOR FREEZE PROTECTION AND TEMPERATURE MA1 NTENANCE.
3. THE TANK I S PROVIDED WITH THERMAL INSULATION AND PROTECTIVE ALUMINUM JACKETTING AROUND THE WHOLE (23) FEET FROM BOTTOM OF THE TANK.

OPERATIONS TO INSTALL TEMPORARY GAUGE AT TIME OF TESTING.

CIRCUMFERENCE AND UP TO A HEIGHT OF TWENTY-THREE

10. THREADED NIPPLE & CAP TO BE PROVIDED FOR 2CT-V144SAB-1 I

\\

I CT24-ISAB - I 2CT-V188SA-1 V

2 2CT-VI89 SA tr S I S RHR PUMP A & B OUTLETS CAR-2165-G-810 (C18) rn T-I rn Q

v, u3 I

CY I-o m

/ 1 2 C T 8 - 7 7 S A - I )

(2CTX-178SA-1)1 I

I 2CT2 - 28SAB-1 HYDRO TEST m -t (2CT14-9SB-1 >

PRESSURE & TEMPERATURE I N STR U M E NTATI 0 N I N DOME & ANNULUS AREAS

\\

\\

\\

I T-I cu I

(c>

I-o b

T-

-2CT16-8SAB - 1)

REFERENCE DRAWINGS 2CT-Vl92SA-1 2CT-Vl93SA-1 V

LIST OF DRAWINGS CAR - 13 64 125 PIPING LINE LIST CAR-1364-B-070 VALVE & SPECIALTY LIST CAR-1364-6-069 INSTRUMENT LIST CAR-2 166-B - 432 FLOW DIAGRAM LEGEND CAR-21 65-G-041 0

0 Z

H H

U H

0 F

2 0

(2 CT& - 179 SA-I

/CVCS-CHARGING PUMPS I 1

(,

CAR-2165-G-805 I

044)

C 2CT-V194SA-1 1

Q Z

c3 v,

0 Q

v, o Z

0 H

P SEE DETAIL 1 (c2)

I Z

Z 0

o c-7CT1-167-1 1

1 2CT-X2SB-1 sc-2 (2CT1-180SA-c-

I Q v,

r) n

[HDR. HAS-36 STR, BRANCH ARRGTS.

AND 36 90 BRANCH ARRGTS.]

v, 7

1 1 ///2CT-V47SB-I T2 - 160s B LOCAL SAMPLE 2CT-U 4SB - I n 2 C T - V 2 0 S B - 1 7

~

-VSSB-I 2CT-V87SB-I-L.0, w

2CT-V5S B - 1 1

S I A S I B 7CT1-113-I

-)t

- 1 I

/

F O T E 6) yw 2CT6-19SB-1 SUMP 1A SUMP I B CAR-2165-G-062 1B-SB TRT:

J2SB-1 JOINT CT-XP, rrsl I

I---(

7CT1-111-1 1 U

ED ELECTRONICALLY SIGNED 27 INCORPORATED: EC# 74207 (H I0,H 11,HlZ)

SEE DRAWING 5-G-810 (M2)

FOR CONT.

ELECTRONICALLY SIGNED 26 INCORPORATED: EC# 50619 (H11)

RECIRC. SUMPS C 0 NTAI N M E NT I

25 SPRAY VALVE -1 CHAMBERS L2CT-V126SB-1 IA-SA L*C.

REV -

SC-2 DESCRIPTION DATE I I

DWN I CHK I APPRVD THIS DRAWING HAS BEEN PRODUCED AND I S CONTROLLED ON THE NED CAD/E SYSTEM. ANY REVISIONS TO THIS DOCUMENT SHOULD BE DONE USING THE CAD/E SYSTEM TO ASSURE PROPER CONTROL OF THE ELECTRONIC DRAWING DATABASE.

2CT-JISA-1

-EXP.

JOINT NUCLEAR SAFETY RELATED (Q-LIST)

YES I NO 1 1

PARTIAL I F,P.-Q 0 R.W.-Q O 2CT-VI 2 ISA-1 CAROLINA POWER & LIGHT COMPANY NUCLEAR ENGINEERING DEPARTMENT - RALEIGH, N,C, NONE HARRIS NUCLEAR PROJECT - U N I T I IScALE PLANT:

/2CT-V120SA-I L.C.

FLOW DIAGRAM UNIT I C 0 NTAI N M E NT S P RAY SYSTEM 18 I9 1

2 4

5 6

8 9

10 I1 12 13 14 15 16 I7

CAR-2165-G-051 A

STEAM G E N E RATO R IA-SN r---- -DKl----c I

I I

I I

I NOZZ.

33 E3 C

E F

G H

I J

K L

M N

B

'/I 2SP-V90SB-l

\\

z 2BD2-65SN-1,

I II' 2SP-V89SN-1 F.C.

NOZZ.

N O Z Z F 32 2BD-Vl15SN-1 k

33 c

4 I

I NO&?

31 BY BY BY BY I

&C MECH I&C MECH

--I c

I 2BD-VI 16SN-1 3BD -VI 35SN-1 3BD-Vl08SN-1 t

I E

1 1

(5BD1-36-1

)--

4'

~

2 2BDl-212SN-1 I

ED TO STM. GEN.

WET LAY-UP SYS.

2 165 - G-089 I

I 0

0 o i w c--( 0 2 1/2"-

900# C.S.

I (MI41 BLD. FLG.

5606-14B-I 6BD6-126-1 F

6606-22-1 STEAM G E N E RATO R 16-SN TO FLASH TANK 1X-NNS i

--c@u----c r----

NOZZ, 33 I

I I

I I

I I

1

' C PL - 2 165 - G - 05 1S02 (El)

I 2SP-VB5SB-1

/

I NOZZ.

NOZ NOZZ.

3 30 2BD-V76SN-1 3BD1-31SN-I 5BD6-142-1 I

3BD-Vl7SN-1 f 3BD-V16SN-1

/ A I

i I

/

I I / I T

REFERENCE DRAWINGS:

FLOW DIAGRAM LEGEND CAR-2165-G-041 CAR-2165-G-044 FEEDWATER AND AUX FEEDWATER SYSTEMS SAMPLING SYSTEM EMF PIPING & INST DIAGRAM CAR-2165-G-052 1364 -033329 3BD-V83SN-1 2BD3/4-2 6SN - 1 I

CPL-2165-G-051 SO2 STM. GEN. BLOWDOWN HEAT RECOVERY & CLEAN-UP SYSTEM 2BD-VGSN-1 J

2BD-V24SN-1 I

I STEAM

--Dw----c r----

NOZZ.

33 I

I I

I I

I GENERATOR IC-SN I - I O A

I I

I \\

I 1-ELECTRONICALLY INCORPORATED: EC 66533 (C5, H5, L5) 1 SIGNED & DATED 2FW3/4-48SN-1

~

(

n s

INCORPORATED:

CIRCLED)

ESR 97-00808 1 JwB 1 R p p 1

DLs I

I I

I t

APPROVED DESCRI PTlON REV I DATE 1

THIS DRAWING HAS BEEN PRODUCED AND IS CONTROLLED ON THE NED W / E SYSTEM. ANY REVISIONS TO THIS DOCUMENT SHOULD BE DONE USING THE CAD/E SYSTEM TO ASSURE PROPER CONTROL OF THE ELECTRONIC DRAWING DATABASE.

NUCLEAR SAFETY RELATED (Q-LIST)

NO 0 PARTIAL F.P.-Q O R.W.-Q O YES 3BD-V21SN-1 CAROLINA POWER & LIGHT COMPANY NUCLEAR ENGINEERING DEPARTMENT - RALEIGH, N.C PLANT: HARRIS NUCLEAR PROJECT - UNIT 1 IscALE' NONE DWG NO.

TITLE:

STEAM GENERATOR FLOW DIAGRAM

~

L O

~

~

O

~

~

SYSTEM CAR - 2 165 G-051 18 19 1

I 2

4 5

6 7

8 9

1 1 12 13 14 15 16 17 18 I9 A T L 1 n I IVI OUTDOORS

/

RELIEF VALVE 6CE-R25-1 OUTLET A

E3 C

D E

F G

H I

J K

L M

%Y

\\

6BD1--113-1 A

E C

D E

F G

H I

J K

L M

N 6BD-V86-1 I

6 C E l - 4 0 6 - 1

?"7 10x8 U I 10x8 6BD8 I 6 6 D 8 - 5 8 - 1

~

DET. E3 (TYPICAL EQUIP.

DRAIN) 0 6BD-V62-1 6BD-V61-1 'Q f

6BD6-52-1 66D6-51-1

\\

I 6BD-P3-1 6BD-P2 I

/

6BDl2-57 W

AC D F.O. 9

'v/

6BD8-48-1 6BD-V45-1 I

6BD-V46-1 D

\\2" PLUG 6BD1/2-135-1 OUTDOORS P L U G G E D ~

CONN.

>-m m w 6CE-V346-1

~~ 8407

-1 CONDENSATE CAR-2165-G-04 6BD-V43-1

~

CONDENSE:

1%-NNS 6BD8-35-1 0 6BD-V131-1 6BD-V130- 1 D1-203-1)

I I

I 4

+ + - I -

( 6 8 D & - 1 3 6 - 1

) -u

~~

6BD2-83-1 J

CONDENSATE -\\

M I X I N G NOZZLE 6BD-Vl0l-1

-7BD-Vl79-1 7BD-R5-1 6BD-L1-1 6BD6-22-1 DET. B 6BD-V65-1 (A18) 6BD4-147-1 6BD-V182-la-.

6BD-B5-1 H I 6BD8-34-1 FUSH TANK tx-NNS t

6BD-V180-1 FROM STM GEN 1B-SN CAR-2165-G-051 (JlO I *

~

e.->

TO TCV-8453 I

6BD6-23-1 FROM STM GEN IC-SN I

7BD-V144-1 7803-153-1 CAR-2 165-G-05 1 6BD-V181-LOW COND. TANK CAR-2 165 - G-0 7BD-V170- 1 7BD-V169-1 f 6 B

m 7BD-B6-1

{

u

-(7 B D3/4 - 182 - 3)

-lol i-2 6608-145-1

&

  • r - * -

r-----

1 p N.C.

I 7BD-B29-1 RESIN TRAP 7BD-830-1 I

I 6BD-V142-1 6BD2-109-1 11 7BD-V147-1 T

"t lx-NNS L----

FOR DET.

SEE 2165-G-I05 6BD-H3-1 8 x 4 1 6BD-B4-1 LEI DR V

7BD-V146-1 I TO SEC. WASTE \\

I ACD 7BD-B18-1 P

\\

' I N.C. P cs 7BD-ss B2 6 - 1 I

7BD4-173-1 7BD-B2 7BD-V150-1 7BD-B19-1 REFERENCE DRAWINGS:

FLOW DIAGRAM - STEAM GENERATOR BLOWDOWN SYSTEM U

7BD-B27-1 7BD-V148-1 7BD-V149-1 GRAB SAMPLE V

n V

089S02(Bll) /

I 7BD-V155-1 '

V 089S02(Bll) /

I 7BD-V161-1 '

7BD-V167-1 I

089S02(B12) /

I';

CAR-2165-G-051 7BD-V151-1 r-l 1

1. REDUCERS ARE SUPPLIED BY LEVEL-CONTROL VALVE VENDOR.
2.
  • VENDOR SUPPLIED DR I I DR

~

RESIN TRAP (7BD3A-160-7BD-V177-1 RESIN TRAP 1C-NNS I

(7BD4-154-1 )-

7BD-V160-1 7BD-V154-1 7BD-V154-1 7BD-V166-1 7BD-B25-1 I

-(

7 B D 3/4 - 17 2 - 1) 7BD-V158-1 7BD-Vl59-1\\ I

___( 7BD4-'156-1)

E3 D 3/4 -

7 6 9 -

\\

\\

\\

\\

\\

\\

\\

\\

\\

\\

\\

\\

\\

\\

\\

\\

\\

\\

\\

\\

\\

\\

\\

\\

\\

\\

\\

\\

\\

\\

\\

\\

\\

\\

\\

\\

\\

\\

\\

\\

\\

\\

7 BD 1 - 2029 - I

\\

\\

\\

\\

\\

\\

\\

\\

\\

\\

\\

h 7BD--'v'176-7 f-I co Q

N I

d-0 m

b 0-L!!J DR f-I N

cs, I

d-c3 b

T-m f-I m b

I d-c3 b

T-m f-I b

b i

d-0 b

t-m 1

DEMIN BED lA-NNS DEMIN. BED IC-NNS DEMIN BED lB-NNS 0-V 7BD1-199-1 7BD-V175-1 t-I co m

N I

rz) c3 cn I'.

P T-I co co I

rz) c3 I'.

.c-m 1 lA-NNS In I

d-c3

-F-I T-I N

0, I

rz)

D b

T-m t-I Q

cn I

r)

D b

f-m T-I 0,

ol)

I r) c3 I\\

t-m 5 /

INCORPORATED: EC# 61953 (C3,C10,C13)

E LECTRON I CAL LY SIGNED I

J.C.

ss 1

1 INCORPORATED: ESR-9600163 4

11/18/98 (B6-B8,C6-C8) 7BD1-198-I 7BD-V174-1 (D4,D5,E5,F4-INCORPORATED:

F6) ESR-9600256 1 LLS 1 RPP 1 NRB 1 DLS v

832-1 7BD-B36-1 ss cs BD-ss 1 LLS I RPP 1 GOW DPK 1 NCORPORATED: ESR-9400033 (AS CIRCLED)

T

-- cs 7BD-B3 N.C 7BD3-194-1

~

7BD3-194-1 INCORPORATED: ESR-9400033 (G I 0 - G15. H I 0 - H 15) 1 LLS 1 RPP 8/4/95 (PARTIAL TURNOVER PER REV. 5)

I U

DR GOW DPK

/

cs REV 1 DATE 1

1 DWN 1

CHK 1

DPE DESCRIPTION DPPE I

COND. DEMIN. SYS. \\

THIS DRAWING HAS BEEN PRODUCED AND IS CONTROLLED ON THE NED CAD/E SYSTEM. ANY REVISIONS TO THIS DOCUMENT SHOULD BE DONE USING THE CAD/E SYSTEM TO ASSURE PROPER CONTROL OF THE ELECTRONIC DRAWING DATABASE.

?-

SLUICE WATER SUPPLY 1

1364-3628 NUCLEAR SAFETY RELATED (Q-LIST)

F.P.-Q 0 R.W.-Q YES I I

NO 0 PARTIAL CAROLINA POWER & LIGHT COMPANY NUCLEAR ENGINEERING DEPARTMENT - RALEIGH, N.C.

\\ \\ \\ \\ \\

\\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\

RESIN TRANSFER TO &

FROM COND. DEMIN. SYS.

1364-3628

- _ _ ~ _ _ _ _

NONE HARRIS NUCLEAR PROJECT - UNIT 1 ISCALE' PLANT:

TITLE:

DWG NO.

I 3

4 5

6 7

8 9

I1 16 17 18 I9 12 13 14

A B

C D

E F

G H

I J

K L

M N

19 18 17 16 15 14 13 12 11 10 9

8 7

6 5

4 3

2 1

A B

C D

E F

G H

I J

K L

M N

19 18 17 16 15 14 13 12 11 10 9

8 7

6 5

4 3

2 1

NONE HARRIS NUCLEAR PROJECT - UNIT 1 CAR-2165 SAMPLING SYSTEM-(NUCLEAR)

FLOW DIAGRAM CONTROL OF THE ELECTRONIC DRAWING DATABASE.

REVISIONS TO THIS DOCUMENT SHOULD BE DONE USING THE CAD/E SYSTEM TO ASSURE PROPER THIS DRAWING HAS BEEN PRODUCED AND IS CONTROLLED ON THE NED CAD/E SYSTEM. ANY NUCLEAR SAFETY RELATED (Q-LIST)

YES NO PARTIAL F.P.-Q R.W.-Q PLANT:

SCALE:

DWG NO.

NUCLEAR ENGINEERING DEPARTMENT - RALEIGH, N.C.

TITLE:

DPPE DPE DESCRIPTION DATE REV 20 G-052 DWN CHK CAR-2165 G-052 THIS DRAWING HAS BEEN ELECTRONICALLY REDRAWN WITH DESIGN CHANGE RCS HOT LEG LOOP 3 CAR-2165-G-800 (H16)

(H5)

CAR-2165-G-800 LOOP 2 RCS HOT LEG RCS PRESSURIZER LIQUID SPACE CAR-2165-G-801 (M5)

(F3)

CAR-2165-G-801 STEAM SPACE RCS PRESSURIZER SIS ACCUMULATOR CAR-2165-G-809 1A-SA (D11)

(G11) 1B-SB CAR-2165-G-809 SIS ACCUMULATOR SIS ACCUMULATOR CAR-2165-G-809 1C-SA (J11)

S F.C.

F.C.

S TUBING BY INSTR.

SEE NOTES 2 & 3 INSIDE MISSILE BARRIER OUTSIDE BARRIER F.C.

S T

M 78A 78B M

T S F.C.

CONN.

TEST TEST CONN.

F.C.

S M

78C T

S F.C.

CONN.

TEST T

S F.C.

CONN.

TEST T

S F.C.

CONN.

TEST PIPING TO TUBING ADAPTER (TYP)

TUBING BY INSTR.

78D M

INSIDE REACTOR CONTAINMENT OUTSIDE REACTOR CONTAINMENT BY MECH.

BY MECH.

BY MECH.

T S F.C.

VENT TEST F.C.

S F.C.

SAMPLING SKID #1 RC POST ACCIDENT TEST VENT F.C.

S T

TEST VENT F.C.

S T

T S F.C.

VENT TEST CAR-2165-G-824 (C13)

RESIDUAL HEAT REMOVAL LOOP REMOVAL LOOP RESIDUAL HEAT (F13)

CAR-2165-G-824 CVCS LETDOWN (D10)

CAR-2165-G-804 REACTOR COOLANT SAMPLE COOLER DETECTOR (RE-1SP-7411)*

GROSS FAILED FUEL DETECTOR BY WESTINGHOUSE DR SEE NOTE 5 COOLING WATER TO COMPONENT (H1)

CAR-2165-G-819 (F19)

COOLING WATER CAR-2165-G-819 FROM COMPONENT 10" VENT CONT. BY HVAC TANK GAS SPACE CVCS VOLUME CONTROL (A12)

CAR-2165-G-805 BLOWDOWN LINE STEAM GEN. 1A-SN (B7)

CAR-2165-G-051 BLOWDOWN LINE STEAM GEN. 1B-SN (G7)

CAR-2165-G-051 BLOWDOWN LINE STEAM GEN. 1C-SN (L7)

CAR-2165-G-051 WATER REACTOR MAKE-UP (F6)

CAR-2165-G-299 WATER DEMINERALIZED (G6)

CAR-2165-G-299 UNLESS NOTED OTHERWISE TYP. FOR PRIMARY SAMPLING PANEL 1A-NNS TUBING RUNS ARE

" STAINLESS STEEL (0.065 WALL)

(UNLESS OTHERWISE NOTED)

TO WASTE CAR-2165-G-814 HOLD-UP TANK (D2)

(D5)

TANK LIQUID SPACE CAR-2165-G-805 CVCS VOL. CONTROL

  • " CONN.
  • " STAINLESS STEEL TUBING NOTE 5 NOTE 5

" STAINLESS STEEL TUBING NOTES:

1. TAPS AVAILABLE FOR BORON ANALYZER IF FUTURE NEEDS DICTATE.
2. TUBING FROM THE RCS HOT LEGS TO THE GROSS FAILED FUEL DETECTOR (GFFD) SHOULD BE ROUTED IN ACCORDANCE WITH THE LAYOUT ON DWG CAR-2166-G-551 SO2. HOWEVER VARIATIONS IN THE ARE SATISFIED.
5. VALVES BY INSTRUMENTATION (BM #3041).

TO WASTE GAS SYS CAR-2165-G-817 (C6)

CHILLER UNIT (BY VENDOR)

V FILL ED 2" DRAIN CONN.

REQUIRED INTERNAL REACTOR COOLANT SAMPLE FLOW SCHEMATIC (BY FIELD)

PRIMARY SAMPLING PANEL 1A-NNS FLOW DIAGRAM-(1364-6774 & 6781)

PANEL ARRGT-(1364-6782)

BTRS DEMIN CAR-2165-G-806 INLET (G16)

(F2)

OUTLET CAR-2165-G-806 BTRS DEMIN CVCS LETDOWN LINE CAR-2165-G-804 AT DEMIN. INLET (B12)

(C14)

AT DEMIN. OUTLET CAR-2165-G-804 CVCS LETDOWN LINE DEMINERALIZED CAR-2165-G-299 WATER (H9)

"CONN.-TYP. UNLESS NOTED OTHERWISE 6" VENT CONT. BY HVAC PRIMARY SAMPLING PANEL 1B-NNS FLOW DIAGRAM-(1364-6694)

PANEL ARRGT-(1364-6692) 2" DR. CONN.

TO ED TYP. FOR PRIMARY TUBING RUNS ARE "

STAINLESS STEEL (0.065 WALL)

FD M

88 TEST CONN L.O.

S F.C.

T T

F.C.S HYDRO TEST CONN.

HYDRO TEST CONN.

S F.C.

F.C.

S T

T L.O.

33 M

TEST CONN TO CONTMT ATMOSPHERE INSIDE CONTAINMENT BLDG.

OUTSIDE CONTAINMENT BLDG.

SKID #3 POST ACCIDENT SAMPLING SYS PHASE SEPARATOR PANEL 1X-NNS

" CONN

" STAINLESS STEEL TUBING (.049 WALL)

" CONN

  • " CONN.

TUBING BY I&C SKID #2 POST ACCIDENT SAMPLING SYSTEM ANALYSIS PANEL 1X-NNS 1" CONN.

SEE NOTE 1

'" TUBING BY I&C f"X*"

f"X*"

f"X*"

6"VENT-CONT. BY HVAC CAR-2165-G-824 RHR PUMP 1A-SA CAR-2165-G-824 RHR PUMP 1B-SB ED

  • " CONN.

REACTOR COOLANT POST-ACCIDENT SAMPLING SYSTEM FLOW DIAGRAM-(1364-52455)

TYP. FOR SKIDS UNLESS NOTED OTHERWISE, TUBING RUNS ARE '"

STAINLESS STEEL (0.065 WALL)

DISSOLVED O

CALIBRATION STATION 2

STATION CALIBRATION pH

'" CONN-TYP. ON SKIDS

& CALIBRATION STATIONS, UNLESS NOTED OTHERWISE 1

4 3

2 TO VENT DUCT DMNZD. WATER (G3)

CAR-2165-G-49S02 CONN. TO PORTABLE LAB EQUIP.

GAS GRAB SAMPLE STATION 3" VENT-CONT.

BY HVAC (N1)

CAR-2165-S-058 NI SUPPLY THIS DWG (B6)

SKID #1 POST ACCIDENT SAMPLING SYS COOLER PANEL 1X-NNS

" CONN PORTABLE SAMPLE CASK UNDILUTED LIQUID GRAB SAMPLE POST ACCIDENT SAMPLING CALIBRATION GAS STATION f"

TUBING BY I&C DR V

DR CHILLER (1364-52911)

SERV. WTR. RETURN (M5)

CAR-2165-G- 047 SERV. WTR. RETURN CAR-2165-G- 047 (L12)

SERV. WTR. SUPPLY CAR-2165-G- 047 (I3)

SERV. WTR. SUPPLY CAR-2165-G- 047 (I2)

FD BY VENDOR RESERVOIR FILL CONN V

REFERENCE DRAWINGS VALVE AND SPECIALTY LIST PIPING LINE LIST INSTRUMENT LIST FLOW DIAGRAM LEGEND CAR-1364-B-069 CAR-1364-B-070 CAR-2166-B-432 CAR-2165-G-041 INCORPORATED:PCR-6161 FR-05, FR-06 (I6-I10,J6,J8,J9,K8,L7,L8,L9)

  • " TUBING BR EVAP. FEED BR EVAPORATOR BR EVAPORATOR
  • DOPAK SAMPLER

'" TUBING 1" TUBING V

10/8/93 GRS RPP MMP WAS THIS DWG (L11)

'" CONN.

BY CP&L THIS DWG (H9) 21 INCORPORATED:PCR-6950 (H9, L10, L11) 6/6/94 GRS LLS MMP WAS 7SP2-560-1 7SP1-568-1 7SWf - 1647-1 7SW2-1528-1 7SW2-1530- 1 7SP2-555-1 7SPf-572-1 7SPf-561-1 7SP2-557-1 7SP2-554-1 7SPf-571-1 7SPf-562-1 7SPf-574-1 7SPf-573-1 7DWf-407-1 7SPf-544-1 8MD1-316-1 7SPf-545-1 7SPf-548-1 7SPf-546-1 7SPf-558-1 7SPf-550-1 2SPf-547SN-1 7SPf-550-1 7SP1-559-1 7SP1-543-1 7SP1-549-1 2SP1-542SN-1 7SP1-549-1 7SP1-541-1 7SP2-526-1 7SP1-519-1 7DW1-17-1 7SP2-525-1 7SP1-518-1 7SP1-570-1 7SP2-564-1 7DW1-36-1 7CC4-621-1 7CC4-409-1 2SPf-567SA-1 2SPf-566SB-1 2SPf-565SA-1 1RCf-136SN-1 2RCf-169SN-1 2RCf-30SN-1 2RCf-56SN-1 2

2 2

2 2

2 P9 P10 P11 2

1 3

4 4

5 20 6

1 2

1 16 17 2

3 4

8 9

2 1

1 2

19 18 11 10 1

3 2

23 22 21 12 13 14 15 1

2 3

4 7

6 5

5 K

P8 P7 P6 P5 24 23 P12 15 S3 S2 S1 20 P14 P13 P11 P9 21 22 P1 P4 P3 P2 4SP-V397-1 4SP-V124-1 7SP-V412-1 7SP-V413-1 4SP-V26-1 4SP-V53-1 4SP-V52-1 FCV 9317 FI 7473 FI 7474 FI 7418 PCV 7476 PCV 7474 PI 7411 FCV 7411 FE 7411 TIS 7411 7SW-F1-1 7SP-V447-1 4SP-V381-1 2SP-V115SB-1 2SP-V114SB-1 2SP-V113SB-1 7SW-V1031-1 7SP-V444-1 7SP-V446-1 7SP-V445-1 2SP-V408SB-1 7SP-V414-1 2SP-V409SA-1 7SP-V414-1 7SP-V442-1 7SP-V443-1 7SP-V441-1 7SP-V440-1 7SP-V415-1 2SP-V407SA-1 2SP-V406SB-1 7SP-V415-1 4SP-V382-1 2SP-V116SA-1 2SP-V2SA-1 2SP-V1SB-1 2SP-V12SA-1 2SP-V11SB-1 2SP-V23SA-1 2SP-V111SB-1 2SP-V22SB-1 2SP-V21SA-1 7SP-V439-1 7SP-V438-1 7DW-V368-1 7SP-V411-1 7SP-V410-1 PCV 7473 B

PCV 7465 D

7473 A

THIS DRAWING (M11)

PCV DISTILLATE SAMPLE CAR-2165-G-812 (J7)

CONCENTRATES SAMPLE CAR-2165-G-812 (I7)

PUMPS DISCH. SAMPLE CAR-2165-G-811 (J1)

SAMPLING PANEL 1B-NNS

& CALIBRATION STATIONS DISCHARGE (M14)

CAR-2165-G-804 (D8)

DISCHARGE (H13)

TEST VENT

& DRAIN TEST VENT

& DRAIN "CONN-TYP ROUTING ARE PERMITTED PROVIDING NOTES 3 AND 4 22 LLS INCORPORATED:ESR-9500857 MISSILE CONN. TO PORTABLE LAB EQUIP.

2" CONN (TYP)

T (C3,C4)

RPP TBB SHS 3/25/96 23 LLS (B5)

INCORPORATED: ESR-9700669 RPP JHT WMP 11/11/97 24 ARM (F13-F16,G13-G16)

INCORPORATED: ESR-9500153 SPARE SPARE SPARE RPP N/A DLS 12/30/99 25 JAP N/A (C1)

INCORPORATED: EC# 50779 RPP CRW 10/19/04 SIGNED ELECTRONICALLY (D2, H18)

INCORPORATED: EC# 68189 26 SEE NOTE 6 OF DRAWING CAR-2165-G-0041.

6. CLASS BREAK AT FLOW REDUCER PER NOTE 5 1*"

27 SIGNED ELECTRONICALLY 7SW2-1534-1 7SW2-1532-1 (K13, K14)

INCORPORATED: EC# 89555 1SP-1825 1SP-1826 28 SIGNED ELECTRONICALLY (M8)

INCORPORATED: EC# 88769 & 88770 L.P. DRAIN L.P. DRAIN L.P. DRAIN CONN.

TEST TIMES. A TOLERANCE OF +/-10 FEET IS PROVIDED.

3. THE TUBING RUNS FROM EITHER LOOP 2 OR LOOP 3 RCS HOT LEG SHOULD BE APPROXIMATELY EQUAL SEE CALCULATION NSSS-0044 FOR LENGTHS AND DELAY TO ALLOW THE SAME DELAY TIME FROM EACH LOOP.
4. TUBING FROM M-78A TO THE FIRST SUPPORT UPSTREAM OF M-78A MUST BE ROUTED AND SUPPORTED AS SHOWN ON CAR-2166-G-551 S02.

FOR APPROXIMATELY TEN (10) FEET ON THE DOWNSTREAM SIDE OF PENETRATION M78A, THE RUN CAR-2166-G-551 S02.

MUST BE ROUTED EXACTLY AS SHOWN ON SIGNED ELECTRONICALLY 29 (B2-B3,C2-C3,G18-G19)

INCORPORATED: EC 298244 DUKE ENERGY 30 SIGNED ELECTRONICALLY (I9)

INCORPORATED: EC 406330

1 2

3 4

5 6

7 8

9 10 11 12 13 14 15 16 17 18 19 A

B C

D E

F G

H I

J K

L M

N A

8 C

D E

F G

H E9 G-0071 (N8)

Y

- A A V Af 45' ELL'S T-I 03 CY I z

ZJ

--b OUTLINE REPRESENTS FEEDWATER-RESTRAINT STRUCTURE AREA I

I 6

is I

r:

J I

I I,

4 c

I.

iL G-0073 (N10)

P

-I f 4CFi-9' FL, EL 261.00' I

I, 4FW10-9-1

$-EL, 281"5"

\\

G-0073 -

(Jl5) 43 42 4

k

/

I

' -0

_L

/r L

PLAN AT EL 286.00'

  • i.wS!$!!ho-/

30x16 RED I

4FW-Vl04-1 4FW 16 I I

51?

I ;

d-CONDeNSER I X-NNS r

CAPPED 42 F J

1

'1 i CONDENSER

'II TURBINE GENERATOR PARTIAL PLAN AT EL261.00' 24 E-2?

35 t

hl I

AI 4FW-VZ36 - 1 W

-a 4FW -V235 - 1 I

J K

L M

N MATCH LINE SEE G-0074 (L3)

- - ~

1 4FW -V237 - 1 I

\\g 3 1

I SECTION W-W (HANDWHEELS NOT SHOWN FOR CLARITY)

SECT1 ON u-u (HANDWHEELS NOT SHOWN FOR CLARITY) 4FW-V238-1 VALVE STEMS I

I VALVE STEMS FACE NORTH 4FW-V236-1 16 TRANSDUCERS ARE NUMBER ED FE-2010:002 THRU FE-2010:017 FACE NORTH 16 TRANSDUCERS ARE NUMBERED FE-2011:002 TH RU FE-2011:017 4 L I

rlI-----.;1 I

PLAN AT EL261.00' ENLARGED PLAN W

W SECTION V-V LEFM A LEFM B TUBING TO Jfl 4FW-V240-1 10" (REF)

PT-2024 & 2025 1

G-0073 (M11)

INCORPORATED: EC 77774 (C4-C7,D4-D7,H13-H18, ELECTRONICALL)

I 13-119,J 1 3 4 19, K1!-

K19, L I S L17, M 13-M17, N 13-N17)

SIGNED INCORPORATED: EC# 61953 (C18,GI 1, I 1 1)

VALVE STEMS FACE NORTH 4FW-VZ39 - 1 16 TRANSDUCERS ARE NUMBERED FE - 20 I 2 : 002 TH R U FE - 20 1 2 : 0 1 7 D

THIS DRAWING HAS BEEN ELECTRONICALLY REPRODUCED AND REVISED I

I 2-5 P

27 29 PROFESSIONAL ENGINEER:

N/A ENLARGED PLAN AT EL 261.00' SCALE I /4"*

I '- 0" QUmLEVEL:

SAFETY RELATED I N PART ONLY I

cp&L CAROLINA POWER & LIGHT COMPANY NUCLEAR ENGINEERING DEPARTMENT -

ISCALE:

AS NOTED PLANT: HNP m:

FEEDWATER PIPING PLANS - SHEET - 2 DWG PLANT NO.:

CAR-2165-G-0072 1

2 3

4 5

6 7

8 9

10 11 12 13 14 15 16 17 18 19

BY VENDOR (1364-3628)(TYP)

RINSE RECYCLE PUMP DRAIN CAR-2165-G-185 (F16) 1A NNS 1B NNS 1C NNS 1D NNS 1E NNS 1F NNS HYDROGEN INNER-COOLED GENERATOR FD FAN COOLER AH-86 1A-SA 1B-SB AH-86 FAN COOLER 2"

FD BY VENDOR BY PLUMB (FIELD RUN)

COIL DR.

BY VENDOR BY PLUMB (FIELD RUN) 2" COIL DR.

COIL VENT COIL VENT EMERGENCY SERVICE WATER INTAKE STRUCTURE FAN COOLERS NOTES:

1. FOR TT-2121 & TC-2121, REFER TO DRAWING 1364-3611 (I-R DRAWING R-43648-A) FOR INSTALLATION DETAILS. FOR TE-2355 & TS-2355. REFER TO FCR-SM-344R1.
2. FOR DETAILS OF THESE CONNECTIONS SEE DRAWING 1364-1145.
3. LOCATE VENT FAR AWAY FROM PERSONNEL TO THE ATMOSPHERE.

AND ANY SOURCE OF IGNITION. VENT

4. INDICATES PIPING/EQUIPMENT TO BE SUPPLIED BY VENDOR.
5. FLEX HOSE FOR IA OR CO PURGE CONNECTIONS.

2 9A 10 9

1 4

3 5

6 7

8 (1364-1556)

CARBON DIOXIDE LOW POINT PURGE AT MAIN LEAD BOX.

CARBON DIOXIDE FEED AND PURGE AND PURGE HYDROGEN FEED LOW PRESSURE GAUGE LINE HIGH PRESSURE GAUGE LINE GAS DRYER FEED HYDROGEN PURITY METER SAMPLING LINE GAS DRYER RETURN REMOVABLE LINK GENERATOR CONDITION MONITOR (1364-93078,

-94460,-94461)

T DR OIL/MOISTURE TRAP DR CO PRESSURE CONTROL STATION 212C267 EB. DWG.

2 NO. 1364-1555 NO. 1364-1555 212C267 EB. DWG.

CONTROL STATION HYDROGEN PRESS.

NOTE 3 OUTSIDE TURBINE BLDG.

INSIDE TURBINE BLDG.

FD DIOXIDE SUPPLY FROM CARBON CAR-2165-G-058 (L10)

(L11)

CAR-2165-G-058 FROM HYDROGEN SUPPLY TURBINE GENERATOR H & CO SYSTEM 2

2 27 DRIP LEG (TYP)

TURBINE-GENERATOR HYDROGEN CONTROL PANEL EBASCO DWG NO. 1364-1150 BY MECH.

BY I&C 28 29 30 NOTE 5 HYGROMETER SENSOR PROBE HYGROMETER SENSOR CABLE MA-8053 MONITOR DEW POINT IN OUT TUBING TUBING TUBING (1364-96837)

GAS DRYER HYDROGEN SS CS CS SS DR DR DR 1"

1" TUBING DR HEATER DRAIN PUMP SEAL WATER SYSTEM A

B C

D E

F G

H I

J K

L M

N 19 18 17 16 15 14 13 12 11 10 9

8 7

6 5

4 3

2 1

A B

C D

E F

G H

I J

K L

M N

19 18 17 16 15 14 13 12 11 10 9

8 7

6 5

4 3

2 1

NONE HARRIS NUCLEAR PROJECT - UNIT 1 CAR-2165 MISCELLANEOUS SYSTEMS FLOW DIAGRAM CONTROL OF THE ELECTRONIC DRAWING DATABASE.

REVISIONS TO THIS DOCUMENT SHOULD BE DONE USING THE CAD/E SYSTEM TO ASSURE PROPER THIS DRAWING HAS BEEN PRODUCED AND IS CONTROLLED ON THE NED CAD/E SYSTEM. ANY NUCLEAR SAFETY RELATED (Q-LIST)

YES NO PARTIAL F.P.-Q R.W.-Q PLANT:

SCALE:

DWG NO.

NUCLEAR ENGINEERING DEPARTMENT - RALEIGH, N.C.

TITLE:

DESCRIPTION DATE REV G-088 DWN CHK CAR-2165 G-088 CONDENSATE CAR-2165-G-045 (L8) 6HD-U3-1 6HD-U1-1 V

1A-NNS 6HD-U2-1 6HD-U4-1 V

1B-NNS (J14)

CAR-2165-G- 045 (I14)

CAR-2165-G-045 PUMP SUCTION TO CONDENSATE PUMP DISCHARGE FROM COND.

6CE-U15-1 1A-NNS FROM COND. TRANSF.

PUMP DISCHARGE CAR-2165-G-045 (F10) 1B-NNS 6CE-U16-1 FROM COND.

PUMP DISCHARGE TO CONDENSATE PUMP SUCTION CAR-2165-G-045 (I15)

CAR-2165-G- 045 (J15)

CONDENSATE PUMP SEAL WATER SYSTEM FROM CB PUMP CAR-2165-G-045 (N6)

DISCHARGE DISCHARGE (N8)

CAR-2165-G-045 FROM CB PUMP TO PUMP BEDPLATE DRAIN 1A-NNS MECH SEAL (TYP) 1B-NNS DRAIN BEDPLATE TO PUMP CONDENSATE BOOSTER PUMP SEAL WATER SYSTEM STEAM GENERATOR FEED PUMP SEAL WATER SYSTEM 1A-NNS F.O.

6CE-S12-1 6CE-S13-1 F.O.

6CE-U3-1 SS CS CS SS F.O.

6CE-S10-1 6CE-S11-1 F.O.

1B-NNS 6CE-U4-1 (J3)

SHELL SIDE FEED PUMPS SEAL BLEEDOFF TO HTR #4 CAR-2165-G-043 (H12)

SEAL INJ. FROM COND.

BOOSTER PUMP DISCH.

CAR-2165-G-045 CS SS 1*X1" RED.

(TYP)

(TYP) 6CE-V260-1 (TYP) 4X2* RED.

SEE NOTE 1

6X4 RED.

1 NOTE SEE 4X2* RED.

4X2* RED.

SEE NOTE 1

1 NOTE SEE 4X2* RED.

6X4 RED.

FD (G13)

SEAL DRAIN TO COND.

FEED PUMP CAR-2165-G-045 FEED PUMP SEAL STEAM GENERATOR 1X-NNS DRAIN TANK (150 GAL.)

(TYP)

(TYP)

FD (TYP)

F.C.

3" FD FD VENT(TYP) 1X-NNS CONDENSER f"

(TYP)

(TYP)

ZONE 2 (RIGHT)

ZONE 2 (LEFT)

'" TUBING ZONE 1 (RIGHT)

ZONE 1 (LEFT)

FROM NITROGEN CAR-2165-G-058 SUPPLY (J6)

FD FD V

V FD FD (TYP)

(TYP)

V V

(TYP)

(TYP)

(TYP)

(TYP)

CONDENSER TUBESHEET PRESSURIZATION SYSTEM CONDENSER IGTS PRESSURIZATION TANK 1X-NNS (150 GALS)

(D10)

CAR-2165-G-045 TRANSFER PUMP DISCH.

FROM CONDENSATE FD 6NI-P15-1 (SET @ 50 PSI)

B.F.

(TYP)

(TYP)

CONDENSER 1X-NNS ZONE 1 ZONE 2 EBASCO CP& L EXPANSION JOINT (TYP) 1*"

1*"Ú CP& L EBASCO FROM COND. PUMP 1A DISCH.

(K13)

CAR-2165-G-045 FLOAT VALVE BY FIELD (TYP)

FD FD PIPE TO TUBING ADAPTER (PLUGGED)

BY FIELD L.O.

PIPE TO TUBING ADAPTER (PLUGGED)

(TYP)

PIPING ARRG'T FOR CONDENSER EXPANSION JOINT WATER SEAL TROUGH REFERENCE DRAWINGS:

FLOW DIAGRAM LEGEND CAR-2165-G-041 FLOW DIAG. HTR. DR. & VENT SYS.

EVACUATION SYSTEM FLOW DIAG. CNDS & AIR STEAM SYSTEM FLOW DIAGRAM EXTRACTION CAR-2165-G-043 CAR-2165-G-045 CAR-2165-G-046 FLOW DIAG. MISC. GAS SYS.

CAR-2165-G-058 2*" CONN.(TYP) 1'" CONN.

(TYP)

CS SS CONDENSATE POLISHING DEMINERALIZERS 1"

1" F

7HY-F1-1 FLOW DIAG. CIRC. & SERV. WTR. SYS.

CAR-2165-G-048 FLOW DIAG. CIRC. & SERV. WTR. SYS.

CAR-2165-G-047 F.C.

NOTE 2 (TYP)

V 7CE-V336-1 7CE-V335-1 7CE-V332-1 7CE-V331-1 7CE-V232-1 7CE1-254-1 6CE3-81-1 6CE3-81-1 6CE-V253-1 6HD-V65-1 7HY*-3-1 7CG1*-3-1 7CE1-338-1 6CEf-282-1 7HY*-63-1 7CE1-253-1 7CE1-251-1 7HY*-70-1 6CE*-277-1 7CE2-337-1 7CE1-216-1 6CE1*-144-1 6CE*-312-1 6CE2-329-1 6CE1*-330-1 6CE1*-331-1 7CE1*-332-1 7CE1*-333-1 7CE1*-335-1 7CE1*-334-1 7CE* - 265-1 7CE1-257-1 7CE1*-266-1 7CE1-255-1 6NI1-274-1 6NI1-273-1 7CE1*-250-1 7CE1-256-1 7CE1*-249-1 7CE1-251-1 7CE1-279-1 7CE1-280-1 7CE1-258-1 7CE'-296-1 7CE1-252-1 7CE*-261-1 7CE'-295-1 7CE*-262-1 7CE*-264-1 7CE1-253-1 7CE'-298-1 7CE1-254-1 7CE'-297-1 7CE*-263-1 7CE1-280-1 7CE3-182-1 7CE4-181-1 7CE30-200-1 7CE1-217-1 7CE1-314-1 7CE2-240-1 7CE2-199-1 7CE2-199-1 7CE4-158-1 7CE6-374-1 7CE4-373-1 7CE4-369-1 7CE2*-150-1 7CE2*-151-1 7CE4-372-1 7CE4-371-1 7CE6-370-1 7CE4-368-1 7CE4-367-1 7CE2*-149-1 7CE2*-148-1 6CE2-202-1 6CE2-133-1 6CE2-135-1 6CE3-183-1 6CE3-184-1 6CE1*-139-1 6CEf-185-1 6CE1*-136-1 6CE2-201-1 6CE2-134-1 6CE2-132-1 6CE3-218-1 6CE1-71-1 6CE2-156-1 6CE3-81-1 6CE1*-138-1 6CE1*-142-1 6CE1*-147-1 6CE1*-143-1 6CE1*-146-1 6CE2-96-1 6CE1*-145-1 6CE1*-137-1 6CE1*-140-1 6CE1*-141-1 6CE*-277-1 6CE*-278-1 6CE*-276-1 6CE*-275-1 6CE*-272-1 6CE*-274-1 6CE*-273-1 6CE*-271-1 6CE*-286-1 6CE*-285-1 6CEf-284-1 6CEf-281-1 6CEf-283-1 6HD*-124-1 6HD*-134-1 6HD*-136-1 6HD*-122-1 6HD*-133-1 6HD*-119-1 6HD* - 123-1 6HD* - 138-1 6HD*-118-1 6HD*-116-1 6HD*-137-1 6HD*-135-1 6HD*-121-1 6HD*-115-1 6CE* - 311-1 7HY*-66-1 7HY*-68-1 7HY*-65-1 7HY* 1 7HY* 1 7HY* 1 7HY* 1 7HY*-69-1 7CG* 1 7HY*-63-1 7HY* 1 7HY* 1 7HY* 1 7HY* 1 7HY*-3-1 7CG1*-3-1 7HY* 1 7HY1-32-1 7CG1* 1 7HY2 1 7HY*-57-1 7HY*-56-1 7HY*-58-1 7HY*-55-1 7HY*-54-1 7CG* 1 3SW*-1535SB-1 3SW*-1526SA-1 3SW*-1525SA-1 3SW* - 1536SB-1 7CE1-343-1 7CE1-342-1 7CE1-341-1 7CE1-340- 1 7CE1-339-1 7CE1-338-1 6CE-V312-1 6CE-V312-1 B2 2355 6CE-V99-1 6CE-V344-1 6CE-V90-1 6CE-V90-1 6CE-V90-1 6CE-V254-1 FS 1258 A

FS 1258 A

6HD-V71-1 7HY-V33-1 7CG-V10-1 7HY-V37-1 7HY-V54-1 7HY-V55-1 6CE-V310-1 6CE-V311-1 6CE-V312-1 7CE-V252-1 7CE-V241-1 6NI-V197-1 6NI-V196-1 7CE-V233-1 7CE-V234-1 7CE-V250-1 7CE-V235-1 7CE-V237-1 7CE-V236-1 7CE-V208-1 6CE-V86-1 6CE-V156-1 6CE-V157-1 6CE-V158-1 6CE-V71-1 6CE-V94-1 6CE-V95-1 6CE-V109-1 6CE-V106-1 6CE-V98-1 6CE-V97-1 6CE-V91-1 6CE-V92-1 6CE-V110- 1 6CE-V112-1 6CE-V89-1 6CE-V88-1 6CE-V255-1 6CE-V259-1 6CE-V258-1 6CE-V254-1 6HD-V68-1 6HD-V69-1 6HD-V66-1 6HD-V67-1 6HD-V64-1 6HD-V63-1 6HD-V62-1 6HD-V61-1 7HY-V52-1 7HY-V44-1 7HY-V42-1 7HY-V49-1 7HY-V34-1 7HY-V33-1 7HY-V51-1 7HY-V46-1 7HY-V37-1 7HY-V35-1 3

3 7HY-V56-1 7CE-V314-1 7CE-V313-1 7CE-V238-1 7CE-V239-1 7CE-V232-1 7CE-V242-1 7CE-V251-1 7CE-V251-1 7CE-V179-1 7CE-V272-1 7CE-V209-1(TYP) 6CE-V87-1 6CE-V299-1 6CE-V96-1 6CE-V99-1 6CE-V93-1 6CE-V90-1 6HD-V70-1 6HD-V56-1 6HD-V73-1 6HD-V74-1 6HD-V54-1 6HD-V72-1 6HD-V71-1 7HY-V53-1 7HY-V50-1 7HY-V43-1 7HY-V45-1 7HY-V41-1 7HY-V47-1 7CG-V10-1 7HY-V29-1 7HY-V38-1 7HY-V36-1 3SW-V726SA-1 3SW-V731SB-1 3SW-V725SA-1 7CE-V177-1 6CE-V113-1 SG SG 7HY-V48-1 7HY-V48-1 PI 1915 LG 1915 LS 1915 PCV 9852 PC 9852 LS 2361 LS 2360 LC 2360 LG 2360 PS 2120 LG 8053 SG LS 8053 LG 8050 SG LG 8051 SG SG LG 8052 PI 1916 B

PI 1916 A

PI 1916 C

PI 1916 D

LCV 2360 TT 2121 B2 TC 2121 B2 TE 2355 TE 2355 B1 TC 2121 B1 TT 2121 B1 TT 2121 A2 TC 2121 A2 TE A2 TE 2355 A1 TC 2121 A1 TT 2121 A1 TT 2121 B

TE 2350 B

TT 2121 A

TE 2350 A

TCV 2121 B2 TCV 2121 B1 TCV 2121 A2 TCV 2121 A1 FS 2345 B2 FS 2345 B1 FS 2345 A1 FS 2345 A2 FS 2340 B

FS 2340 A

FS 1258 B

FS 1258 A

7CE-V178-1 7CE-V177-1 7CE-V176-1 7CE-V334-1 7CE-V333-1 7CE-V330-1 7CE-V329-1 6CE-V345-1 6NI-V198-1 7CE-V247-1 7CE-V245-1 7CE-V243-1 7CE-V244-1 7CE-V246-1 6CE-V108-1 6CE-V107-1 6CE-V111-1 6CE-V113-1 6CE-V257-1 6CE-V253-1 6CE-V256-1 6CE-V271-1 7HY-V48-1 7CE-R13-1 7CE-L3-1 6CE-M5-1 6CE-M6-1 6CE-M3-1 6CE-M4-1 6CE-P2-1 W DWG NO. 7146D56 W DWG. NO.

W DWG. NO.

3SW-V732SB-1 6CE-V373-1 6CE-V270-1 6CE-V374-1 6HD*-117-1 6HD*-120-1 ARM SEAL MECH.

SEAL MECH.

HD PUMP SEAL WATER CAR-2165-G-046 (I3)

HD PUMP SEAL WATER CAR-2165-G-046 (I8) 28 (A18,A19,B18)

(PARTIAL TURNOVER PER REV 6 INCORPORATED: ESR 95-01000 APPR'D RPP DLS 4/26/00 29 ARM (C8,C9,D8,D9,E8,E9)

INCORPORATED: ESR 00-00192 EJE DLS 5/7/00 3

3 30 ARM E17-E19,F17-F19)

(A16-A19,B16-B19,C17-C19,D18,D19, INCORPORATED: ESR 95-01000 JWB DLS FOR RPP 11/1/00 0803 PI 7HY-V39-1 7HY*-72-1 7HY*-73-1 VENT (TYP)

VENT 31 ARM (D13-D15,E13,E14,F14-F16,G15-G17),

INCORPORATED: ESR 00-00257 7HY-V52-1 7HY-V51-1 7HY*-71-1 ESR 00-00289 (I2,I6) 11/17/01 RPP DLS 32 CS SS CS SS 6CE2-408-1 6CE-V265-1 AND DATED ELECTRONICALLY SIGNED C1-C4, D1-D4, E1-E4, F1, F2)

INCORPORATED: EC# 60439 (A1-A4, B1-B4, AND DATED ELECTRONICALLY SIGNED (C8, C9, D8, D9, E8, E9)

INCORPORATED: EC# 68194 33 6CE-U13-1 6CE-U14-1 6CE-U11-1 6CE-U12-1 6CE-U7-1 6CE-U8-1 6CE-U10-1 SS SS CS CS SS CS SS CS SS CS SS SS SS CS 6CE-U9-1 AND DATED ELECTRONICALLY SIGNED 34

( D18, D19, E17, E19)

INCORPORATED: EC# 75606 35 ELECTRONICALLY SIGNED (H11,H12)

INCORPORATED: EC# 402940 DUKE ENERGY

17 18 19 20 12 13 14 15 16 1

2 3

4 5

6 7

8 9

10 11 CPL-2165-G-089S01 I

Rm.

CoOuNC WATER ISOUTION SKID IX-NNS (WM-06774) i (y

~~~~~ <5m-1741-1

)

i i

i m - W U I - 1 (1364-06777) i SAMPLE RF:CLAMATION SYSTEM i

2 I

)

4

(

I I

3 4

5 6

7 8

9 I 1 I2 13 14 15 16 17 I8 19 1

V 7 2 4 7 S P H - 620 -J CPL-2165-A B

C D

E F

G-089S02 6CE-V358-1 6CE-V357-1 COND. PUMP 1B-NNS COND. PUMP 1A-NNS 6CE-v35e-1\\

\\ &

DISCHARGE 2 165-G-045 2" FN PT x' FNPT T

I DISCHARGE 2165-G-045 x' TUBING J

( 6CE1-391-1 I

1" FNPT MAKEUP FN PT

\\%'

TUBING E

c c

E F

c t

I I v L

n I

I TEMPERATURE CONTROL UNIT TCU-2X-NNS (1364-098345, 1364-098348)

WASTE SUMP C&D 2165-S-0185 FEEDWATER D 0 2 CP MONITOR PAN l L

IC-NNS (1364-098346)

I I

(3 Z

1 m

-1 0

Q-w H

Z 0

2 2

0 0

(3 ZI 1

H Ei (3

Z 1

m H

T a

SPARE CON N ECTI ONS

'r'

'7/ 'r' Y

/-f 7SP3/4-614-1 )

f-1 CHILLED COOLING WATER SUPPLY C PL-2 165 - G -089S01 CORROSION MONITOR

/

I COOLING WATER RETURN i

CPL-2165-G-089 SO1 L

I T2B 1 I

I I

\\

I COOL1 NG WATER SUPPLY CPL-2165-G-089 S01 (CI) f

\\'I I

I SAMPLE CONDITIONING RACK 1X-NNS (1364-96769 THRU 96774)

(1364-96777)

(1364-97461) 7SP2-596-1 7SP2-6 0 4 - 1 (-----+

CORROSION MONITOR TABLE TOP SINK I

\\

I CHILLED COOLING WATER RETURN CPL-2165-G-089 SO1 I

T I B I

G

\\

CHILLED COOLING WATER SUPPLY CPL-2165-G-089 S 0 I (GI)

A CORROSION MONITOR 1B-NNS 7s P 2 - 600 - 1 I

2%') x 2" -

RED TYP.(4 PLCS)

H T19B DRAIN HDR. TO SAMPLE RECLAM, DRAIN TANK CPL-2165-G-089 S01 (J 1) 1 (S7A)

\\

I

\\

/-

\\

\\ - /

1

-(

7SP2-595-1

)

P I P I N G TUBING J

WET ANALYZER PANEL 1A-NNS (1364-96802)

(1364-96803)

(1364-97460)

WET ANALYZER PANEL 1B-NNS

(, S3A)

(, S3A)

I 7-(1364-96799)

(1364-96800)

(1364-96801)

K I

INCORPORATED: EC# 77775 (I

12 -I 14, J 12-J 14, K12 - K14, L9 - L E )

5 ELECTRONICALLY SIGNED AND DATED INCORPORATED: EC# 48014 (A13-AI6, B10- 6 16,C 10, H 14)

I I

I I

I INCORPORATED: E S R - 9 4 0 0 0 3 3 (B 10- B12,C 10-C13,F6, H 6, H 9,I 1,I 6-19, 1

LLS 1 RPP I GOW 1 DPK J7,K7,K8,KS,KIW,LS,L7)

I L

1 DKC TURNOVER PER FR07 (B11)

MMP GRS LLS FOR WAS I

N CORPORATED: PCR - 39 22 PARTIAL 1

2/22/94 M

0 2/3/94 ISSUED PER PCR-5503 AND 5514 GRS LLS MMP WAS REV RATE DWN CHK DPE DPPE DESCRIPTION THIS DRAWING HAS BEEN PRODUCED AND I S CONTROLLED ON THE NED CAD/E SYSTEM. ANY REVISIONS TO THIS DOCUMENT SHOULD BE DONE USING THE CAD/E SYSTEM TO ASSURE PROPER CONTROL OF THE ELECTRONIC DRAWING DATABASE, NUCLEAR SAFETY RELATED (Q-LIST)

YES C Z Z I l NO -

PARTIAL CIIIZl F.P.-Q R.W.-Q N

8c CAUSTIC WASTE SUMP CPL-2165-G-089S01 CAROLINA POWER 8c LIGHT COMPANY NUCLEAR ENGINEERING DEPARTMENT - RALEIGH, N.C I

NONE PLANT:

~

HARRIS NUCLEAR PROJECT - UNIT I IscALE:

-(

7SP2-609-1

)

)

w I DWG NO.

TITLE:

FLOW DIAGRAM SECONDARY SAMPLING SYSTEM UNIT 1 CHEMICAL SAMPLE RECLAM. DRAIN HEADER CPL-2165-G-089S01 7SP2-608-1 CPL-2165-G-089S02 2

4 5

6 7

8 9

10 I2 13 14 15 16 17 18 I9

LEGEND I

I I

I I

I H&V UNITS CCW SURGE TANK CUBICLE FD(NP)

FL.EL.324.00' CAR-2165 MAIN STEAM DUMP WATER SURGE TANK 1X-SAB WATER SYSTEM H&V UNITS A

B

--.I C

D E

F G

H I

J K -

L M

N HOT SHOP DRAIN EQUIPMENT DRAIN I

CONDENSATE DRAIN FLOOR DRAIN COMPONENT COOL1 NG W. DRAI N CHEMICAL DRAIN REFERENCE v

OPEN EQUIPMENT DRAIN

.b, CLOSED EQUIPMENT DRAIN 111111)

IX-NNS

~

AH-82 IB-NNS IA-NNS I AH-81 1A-NNS FLOOR DRAIN NOTES 1A-SA 1B-SA x

SPRINKLER DRAIN DOWN d S P R I N K L E R DRAIN I

II DOWN TYP.

I I

t u--1 1-ALL LINES BY PLUMBING EXCEPT THOSE WITH LINE NUMBERS AND REFERENCE LINES. (FOR REFERENCE LINES SEE RESPECTIVE SYSTEM DIAGRAMS) 8 i

7 DEMINERALIZER H&V AIR WASHER & FAN 1 (IA&lB NNS)

RM EAC-1 I L--

I R E C Y C n,--,

.. RAB RAB CAP CAP 459 460 RECYC EVAP COND DEMIN CATION f"-'\\

2-FOR EQUIPMENT INSTRUMENTATION OTHER THAN SHOWN HERE, REFER TO APPROPRIATE FLOW DIAGRAM.

EMERG EMERG EXH EXH AH-21 I

I

\\

RECYCLE

~~~ ?A-SA B-SB

-4B-NNI 3-

  • DENOTES BY EQUIPMENT MANUFACTURER.

\\

N A P 1

FEED 4-SEDIMENT BASKET TO BE REMOVED AND ENCLOSURE PLUG INSTALLED WHEN NOT I N USE.

I GALLERY EQUIPMENT RECYCLE MO N I T 0 R HVAC CHILLED CHILLER i

1

~ 1 ~ ' T ' l IA-SA 1B-SB 1X-NNS HVAC CHILLERS WATER PUMPS SERVICE MAKE-UP MAKE-UP WATER PUMPS TANK 1A-SA TANK 1B-SB 1

1 NNS

~~

RECYCLE N A P COND

~1 I, DEMIN, I".-- i nn I

i I

1 I

n STEAM TUNNEL 1 DECONTAMINATION I ROOM EQUIPMENT &

FLOOR DRAIN (WP)

I I

\\

/

446 CAP(NP) 442 444 445 447 MONITO s

D t i"

7 I

/ \\

-n I DETERGENT WASTE\\

I

/

\\

STEAM GENERATOR AUXILIARY FEED PUMPS 1X-SAB SERVICE WATER BOOSTER PUMPS n

~-~

PIPE TUNNELS AT I

~D CVS. CHILLER PUMPS Ti IA-NNS AH-30 i

RECYCLE EVAP FEED PUMP EL.250',254',255' FD (NP) f

\\

IB-SB COMPONENT COOLING WATER HEAT EXCHANGERS CVCS CHILLERS I I FROM SUBMERSIBLE\\

I '

THREADED BY HOSE I1x-sBI i i

/-

WATER DRAIN TANK 4'

PUMP 1X-NNS H4 I'

I 8MD-D4-1

( 8MDZX-10-1 i

FLOOR DRAIN TANK W.P.

BLDG.

2165-G-816 (Fl0)

EVAPORATION UNIT 1 CAR 2165-G-814 FLOW DIAG.WASTE PROC.SYS. FLOOR DRG.

STORAGE & TREATMENT UNIT 1 CAR 2165-G-816 FLOW DIAG.COMPONENT COOLING WTR.SYS.SH l.UN.l CAR 2165-G-819 FLOW DIAG-CONT BLDG & TURBINE GENERATOR BLDG.DRAINAGE SYSTEMS UNIT 1 CAR 2165-G-185 FLOW DIAG, AUX STEAM & COND.RET.SYS.UNIT 1

CAR 2165-G-189 FLOW DIAG. SAMPLING SYS.(NUCLEAR)

UNIT 1 CAR 2165-G-052 SLOW DIAG.WASTE PROC. BLDG.DRG SYS.UNIT 1 CAR 2165-G-428

&8MD2-92-1)

W 8M D-V5-I? qMD-V1O1-p 9 8 M D-V5-1

-8 M D-D6-I

\\@

PORTABLE COMPONENT COOLING WATER DRAIN DRUM I

8MD1-V101-I -

8MD-V142-1 8MD-VI39 -1 SPRAY ADDITIVE DRAIN DRUM 8MD-V136-1 8MD-V233-I 12" EMBEDDED BATTERY ROOM BATTERY ROOM BATTERY ROOM NAG PUMPS CONTAINMENT MAT SUBMERSIBLE 1A SINK

?A-SA SINK 1A-SB SINK 8MD2-171-1 I I I 190.00' DRAINAGE PUMPS n

-.. _ _ n n

2 9 1

INCORPORATED: EC 78036 (E6-E8) 1 ELECTRONICALLY SIGNED DESCRIPTION APPR'D THIS DRAWING HAS BEEN PRODUCED AND I S CONTROLLED ON THE NED CAD/E SYSTEM, ANY REVISIONS TO THIS DOCUMENT SHOULD BE DONE USING THE CAD/E SYSTEM TO ASSURE PROPER CONTROL OF THE ELECTRONIC DRAWING DATABASE.

NUCLEAR SAFETY RELATED (Q-LIST)

YESl-I NO 0 PARTIAL 0 F.P,-Q O R. W. 4 C Z I I I CP&L CAROLINA POWER & LIGHT COMPANY NUCLEAR ENGINEERING DEPARTMENT - RALEIGH, N.C.

Y EL.261.00' THIS DRAWING

~

3" (HI21 HARRIS NUCLEAR PROJECT - UNIT 1 lscALE NONE PLANT DWG NO.

I CAR - 2 165 -

TITLE:

FLOW DIAGRAM REACTOR AU X I LIARY BUILDING ACID NEUTRALIZING TANK 1X-NNS DRAINAGE SYSTEMS G-184 18 143.

NOTE 5 (J1)

CAR-2165-G-090 TREATMENT SYSTEM TO SECONDARY WASTE A

6424 LS B

6424 LS 8MD-V204-1 8MD4 1 8MD1-101-1 8MD4 1 8MD-V101-1 8MD1-101-1 8MD-V106-1 8MD3-35-1 (TYP.)

I&C LS 8MD-V44-1 8MD-V45-1 6420 LS 240.00' FL.EL.

6421 LS 6420 PI 8MD3-35-1 8MD-V44-1 8MD1-101-1 FD(TYP.)

8MD-V45-1 1A-NNS 1B-NNS 3"

3" SUMP PUMP ACID & CAUSTIC CAR-2165-G- 803 (H6)

LEAKOFF (3)REQ'D.

R.C.PUMP NO.3 SEAL (3) REQ'D.

EXCHANGER DRAIN R.C. PUMP HEAT TABLE DRAINS MENTATION SEAL IN-CORE INSTRU-TABLE DRAINS MENTATION SEAL IN-CORE INSTRU-FL EL. 261.00' FL EL. 259.00' 1X-SN HEAT EXCH EXCESS LETDOWN (TYP. OF 3)

WATER OUTLET R.C. PUMPS COOLING AH-1 AH-1 (1B-SB)

(1A-SB)

AH-2 AH-2 (1A-SA)

(1B-SA)

(TYP.)

INST.RACK NNS 1A NNS 1B SEE NOTE 1 1X-SN RACKS (TYP.)

I&C INST.

FL. EL. 221.00' B2 7162 LE B1 7162 LE A1 7162 LE A2 7162 LE SA SA SB SB SA SB B3 7162 LE A3 7162 LE 6440 LS 6441 LS 8MD3-42-1 4"WL 3"WL 3"WL 2"WL 5WL3-313-1 F.D.(TYP.)

NOTE#1 SEE F.D. & TEST. CONN.

8MD-V256-1 8MD1-218-1 2MD-V36SA-1 M74 2MD-V77SB-1 IRC ORC OMB IMB 8MD3-44-1 2MD3-49SAB-1 8MD3-43-1 8MD1-158-1 8MD-V34-1 V

8MD-V213-1 TEST VENT (A4)

CAR-2165-G-814 UP TANK SEE DWG TO WASTE HOLD-8MD3-150-1 8MD1-122-1 8MD-V122-1 6440 PI DRAIN SUMP PUMPS TANK AREA EQUIPMENT 1A-NNS 1B-NNS 2"

2" 8MD1-101-1 1A-NNS 1B-NNS 4"

4" SA A

7161 LE B

7161 LE SB 213.00' FL.EL.

4" VENT SUMP 8MD-V35-1 8MD-V76-1 8MD1-126-1 8MD-V112-1 8MD-V75-1 CONTAINMENT BUILDING PUMPS CONTAINMENT SUMP BOTT. OF SUMP EL. 207.50' VESSEL CAVITY REACTOR EL. 211.50' 7SF-D219-1 FL.EL.246.00' CAVITY REFUELING DRAIN MISC. PIPE C.C.W PIPING DRAINS (TYP.)

THAN C.C.W (TYP.)

MISC. PIPING DRAINS OTHER 4"C.C.W 6"C.C.W 4"C.C.W WATER PUMPS REACTOR MAKE-UP (A4)

CAR-2165-G-814 UP TANK SEE TO WASTE HOLD-1A-SN 1B-SN 6432 LS 8MD2-116-1 8MD-V106-1 8MD1-106-1 8MD-V40- 1 8MD-V39-1 8MD-V101-1 6433 LS 8MD-V39-1 8MD-V40- 1 SAMPLE TANK PUMPS SECONDARY WASTE 1&2A-NNS 1&2B-NNS 6432 PI 8MD2-115-1 8MD4-209-1 236.00' FL. EL.

25,000 GAL.

1&2B-NNS 25,000 GAL.

1&2A-NNS 8MD3-46-1 8MD3-45-1 8MD4-48-1 8MD1-434-1 8MD1-101-1 8MD-V101-1 8MD-V343-1 8MD-V41-1 8MD1-101-1 8MD-V101-1 8MDf-233-1 8MDf-423-1-4 8MD-V429-1 DRAIN PUMP TANK AREA 8MD4-39-1 8MD-V51-1 8MD-V423-1 8MD-V50-1 8MD-V57-1 8MD-V60-1 8MD-V61-1 8MD-V58-1 8MD-V59-1 8MD-V62-1 4"

4" 4x3 REDUCER 6x3 REDUCER 8MD3-47-1 BY PLMB BY MECH MONITOR RADIATION G-105 (C4)

SEE DWG.

DETAIL FOR 8MD1-106-1 6430 PI 8MD2-40-1

  1. 10 HOOD SAMPLE 8MD-V37-1 8MD-V38-1 8MD2-40-1 6430 LS 6431 LS 8MD-V101-1 8MD-V37-1 8MD-V38-1 8MD1-101-1 8MD2-117-1 1A-NNS 1B-NNS 2"

2" SUMP PUMPS TANK AREA FLOOR DRAIN 1X-NNS 1B-NNS RECEIVER INSTR AIR 1C-NNS (TYP.)

AFTERCOOLER FLR EL. 261.00' 1B-NNS RECEIVER SERVICE AIR WASTE MONITOR TANK PUMPS INSTR (TYP.)

(FOR REFERENCED LINES SEE RESPECTIVE SYSTEM DIAGRAMS)

AND REFERENCED LINES.

2. ALL LINES BY PLUMBING EXCEPT THOSE WITH LINE NUMBERS
3. FOR EQUIPMENT INSTRUMENTATION OTHER THAN SHOWN HERE, REFER TO APPROPRIATE FLOW DIAGRAM.
5. FLANGED CONDENSER DRAIN DOWN CONN'S.
4.
  • DENOTES BY EQUIPMENT MANUFACTURER.

NOTES REFERENCE DRAWINGS SYSTEM EFFLUENT TREATMENT COND VAC PUMP 5-G-105(E4)

SEE DWG FOR DET.

G-105(F4)

CAR-2165-DW SUPPLY SAMPLER LIQUID AUTO ISOLOK 6422 FQ SAMPLER 8MDf-437-1 CAR-2165-G-090(D1)

TREATMENT SYS.

SECONDARY WASTE 8MD3-35-1 8MD-V47-1 8MD-V46-1 8MD-V46-1 8MD-V47-1 3"

3" 1B-NNS FD(TYP.)

(TYP.)

DRAINS MISC PIPE RACKS (TYP.)

I& C INST.

286.00' FL. EL.

261.00' FL. EL.

VALVE PIT TANK 1 & 2X-NNS WASTE SAMPLE SECONDARY WASTE MONITOR TANKS CONTAINMENT FAN COOLERS BOX WTR BOX WTR BOX WTR BY PLMB BY MECH 3534 REM 8MD-V419-1 8MDf-421-1 (D8) 5-G-105 SEE DWG.

FOR DET.

REV DATE DESCRIPTION TITLE:

NUCLEAR ENGINEERING DEPARTMENT - RALEIGH, N.C.

CAROLINA POWER & LIGHT COMPANY DWG NO.

SCALE:

PLANT:

NUCLEAR SAFETY RELATED (Q-LIST)

THIS DRAWING HAS BEEN PRODUCED AND IS CONTROLLED ON THE NED CAD/E SYSTEM. ANY REVISIONS TO THIS DOCUMENT SHOULD BE DONE USING THE CAD/E SYSTEM TO ASSURE PROPER CONTROL OF THE ELECTRONIC DRAWING DATABASE.

CAR-2165-HARRIS NUCLEAR PROJECT - UNIT 1 NONE APPR'D G-185 MOISTURE SEPARATOR REHEATER DR. TANKS MOISTURE SEPARATOR DRAIN TANKS VENT TRHU ROOF 8MD-V415-1 GRAB SAMPLE 1B-NNS

  1. 1 L.P. HEATER 6424 PI 8MD1-148-1 7CE-R24-1 3 X 2 RED.FLG.

8MD3-313-1-4 8MD1-312-1-4 SUMP NEUTRALIZING ACID F.D.(TYP.)

8MD-V349-1-4 7CE1*-288-1 7CE3-328-1 EXH.DUCT HVAC TANK HOT WATER REGEN. TANK CATION REGENT TANK ANION STOR. TANK RESIN SYSTEM SAMPLING SEC.

NNS 1X NNS 1X NNS 1X NNS 1X 1X-NNS 7CE2-337-1 (E14)

CAR-2165-G-429 SAMPLE SYS.

SEE WASTE PROC.

SAMPLE LINES 1A-NNS 4" SUMP VENT 7CA4-39-1 7CA4 1 8MD-V106-1 SUMP PUMPS CONDENSATE PUMP AREA CONTAINMENT FAN COOLERS AH-4 AH-4 AH-3 AH-3 (1B-SB)

(1A-SB)

(1B-SA)

(1A-SA)

HEATER DRAIN PUMP PIT 5-G-184 (E18)

WASTE TO RAB DETERGENT E60(1X-NNS)

UNIT AIR CLEANING H & V (TYP)

FD (TYP)

SHDR 1A-NNS 1B-NNS SECONDARY PANEL CHEMICAL RM.

  1. 1 NOTE SEE 1A-NNS S-1 1B-NNS S-1 5-G-813(H3) 6WL2-326-1 EXCHANGER 1X-SN REGENERATIVE HEAT 8MD-V106-1 8MD1-303-1 8MD4-38-1 8MD1-106-1 ES 6"

HVAC AIR FLOW DIAG. ADMIN, SVCE & MISC. BLDGS FLOW DIAG. WASTE PROC. SYS. FL. ORG. STORAGE & TREAT.

FLOW DIAG. WASTE PROC. SYS. WASTE HOLD UP & VAP FLOW DIAG. CONT. BLDG. WASTE PROC. SYSTEM FLOW DIAG. BORON RECYCLE SH. 1 FLOW DIAG. REACTOR AUX. BLDG DRAINAGE SYSTEMS FLOW DIAG. WASTE PROC. BLDG. DRAINAGE SYSTEMS FLOW DIAG. STEAM GEN. BLOWDOWN SYSTEM FLOW DIAGRAM LEGEND CAR-2168-G-518 CAR-2165-G-816 CAR-2165-G-814 CAR-2165-G-813 CAR-2165-G-811 CAR-2165-G-184 CAR-2165-G-428 CAR-2165-G-051 CAR-2165-G-041 DRAINS TO BE CAPPED. USE PORTABLE DRUM FOR DRAINING.

SHELL DRAIN, AND EXCESS LETDOWN HEAT EXCHANGER SHELL

1. COMPONENT COOLING WATER PIPE DRAINS, R.C.D.T. HEAT EXCHANGER PREFILTER 1B-NNS PREFILTER 1C-NNS PREFILTER PUMP AIR-OP. SUMP CONN. FOR TEMP.

8MD2-146-1 8MD-V205-1 8MD1-149-1 4" SUMP VENT 1A-NNS DECONTAMINATION AREA (TYP)

LAV 8MD-V46-1 8MD4-50-1 8MD4 1 1B-NNS 1C-NNS 1D-NNS 1A-NNS A

6423 LS A

6422 LS FD (TYP.)

8MD-V101-1 8MD-V433-1 8MDf - 439-1 8MD4-51-1 8MD1-106-1 8MD-V106-1 8MD-V47-1 8MD-V46-1 8MD1-106-1 8MD-V106-1 B

6422 LS B

6423 LS SUMP PUMPS INDUSTRIAL WASTE FOR CONT SEE (N17)

DRAINAGE SYSTEM TO YARD STORM 7CE3-379-1 7CE6-380-1

& PUMP ACID TANK 8MD-V206-1 8MD-V207-1 8MD-V208-1

& PUMP TANK CAUSTIC MON RAD 8MD2-147-1 8MD-V260-1 6422 SC B

6422 PI SUPPLY INST. AIR 6422 FE 3528 RE 3528 REM FD (TYP.)

NNS 1A&1B AH-35 DAY TANK FUEL OIL CURB VENT SUMP 8MD-V348-1-4 8MD-V345-1-4 6494 LS 6495 LS 8MD-V344-1-4 8MD1-309-1-4 8MD2-310-1-4 8MD-V347-1-4 8MD-V346-1-4 HEAT EXCHANGER BLOWDOWN REGEN 1X-NNS FLASH TANK PUMPS RECYCLE RINSE VENDOR BY (B16)

CAR-2165-G-088 DEMINERALIZER COND. POLISHING BY VENDOR RACK (TYP.)

I & C INST.

VENT STACK TURBINE BLDG.

(TYP.)

DRAINS MISC. PIPE VACUUM PUMPS CONDENSER 1A-NNS AIR INSTR.

1A-NNS RECEIVER SVCE AIR AIR RECEIVERS AFTERCOOLERS COMPRESSED AIR 1B-NNS AFTERCOOLERS COMPRESSED AIR AIR COMPRESSOR 1B-NNS 1A-NNS 1A-NNS BOOSTER PUMPS CONDENSATE NNS 1A NNS 1B COMPRESSOR AIR 1A-NNS DRAIN DOWN (TYP.)

SPRINKLER FL.EL.261.00' BOX WTR FL.EL.253.00' 1B-NNS 1B-NNS 1A-NNS 1A-NNS 8MD4-119-1 8MD-V428-1 DR 8MD-V432-1 8MD-V436-1 8MDf-443-1 8MDf-433-1 8MDf-438-1 8MD6-442-1 8MD4-119-1 8MD1-300-1 (TYP.)

(TYP.)

8MD-V336-1 8MD4-120-1 EL.296.75' PLATF 1B-NNS

  1. 2 LP HEATER 1B-NNS
  1. 3 LP HEATER 1A-NNS
  1. 4 LP HEATER 1B-NNS
  1. 4 LP HEATER 1A-NNS
  1. 5 HP HEATER 1B-NNS
  1. 5 HP HEATER 8MD1-106-1 8MD-V101-1 242.30' FL.EL.

248.00' FL.EL.

6" 6"

6" 6"

NNS 1A NNS 1B NNS 1C NNS 1B NNS 1A TURBINE BUILDING EL. 248.00' AREA TUBE INSPECTION FUEL TRANSFER 2"C.C.W 1"C.C.W (TYP.OF 3) 3"C.C.W F.D.(TYP.) FL.EL.261.00' 8MD-V387-1 F.D.(TYP.)

f "

1X-SAB (2165-G-045)

TANK STORAGE CONDENSATE (415,000 GAL.)

(85,000 GAL.)

1X-SN (2165-G-299)

STORAGE TANK MAKE-UP WATER REACTOR 1X-SAB (2165-G-050)

STORAGE TANK REFUELING WATER (470,000 GAL.)

DRAIN AREA DRAIN AREA NNS 1&2A NNS 1&2B 8MD4-209-1 FILTERS SGBD TANKS DEMIN SGBD MONITOR RADIATION (F8)

CAR-2165-G- 803 OVERFLOW. (3) REQ'D R.C. PUMP STAND PIPE 250 GAL.

1C-NNS 1A-NNS,1B-NNS, TANKS COLLECTION BEARING OIL R.C. PUMP 8MD2-311-1-4 4"

2" 2"

1A-NNS 1B-NNS LINE LEAK DETECTION SHIELD WALL ON SECONDARY REMOVAL UNITS RADIOACTIVITY AIRBORNE HOTWELL HOTWELL CONDENSER 1B-NNS HEATER DRAIN PUMPS 1A-NNS 261.00' FL.EL.

FD 1'"

1'"

NO.1364-1911,-1912 SEE EBASCO FF DWG.

CONDENSER CONN.#92 TURBINE SLOP DRAIN-NO.1364-1911,-1912 SEE EBASCO FF DWG.

CONDENSER CONN.#91 TURBINE SLOP DRAIN-1'"

NO.1364-1911,-1912 SEE EBASCO FF DWG.

CONDENSER CONN.#93 TURBINE SLOP DRAIN-1'"

NO.1364-1911,-1912 SEE EBASCO FF DWG.

CONDENSER CONN.#94 TURBINE SLOP DRAIN-1X-NNS COND GLAND STEAM 1A-NNS

  1. 2 L.P. HEATER 1A-NNS
  1. 3 L.P. HEATER 1A-NNS
  1. 1 L.P. HEATER DRAINS (TYP.)

MISC. PIPE 1X-NNS H&V AH-34 1A-NNS 1B-NNS 3"

ADDITIONAL AIR EQUIPMENT TURBINE BUILDING C.S.S.S.

BY BY MECH. PLUMB.

8MD-V424-1 (RC PUMPS LWR BRG OUTLET HEADER) 1X-NNS DRAIN TANK REACTOR COOLANT 1"

(TYP.)

RACKS INST 3"

FEED PUMPS STEAM GENERATOR 4"

3" EL.240.00' FLOOR CURB PIT VALVE 1X-NNS OIL UNIT H2 SEAL 8MD2-23-1 (D17)

CAR-2165-G-485 TO OIL SEPARATOR 8MD4-120-1 8MD-V257-1 8MD-V48-1 8MD-V49-1 8MD4-420-1 PUMPS SLUICE F

6425 PI FL. EL. 314.00" 1X-NNS M

M 2

T M

T M

2 (TYP.)

RACKS I&C INST RACKS (TYP.)

I & C INST FD(TYP.)

FD(TYP.)

FD(TYP.)

DRAINAGE SYSTEM TANK AREA & SECURITY BLDG.

CONTAINMENT, TURBINE BLDG, FLOW DIAGRAM MONITOR RADIATION VENT (TYP.)

4" SUMP FROM (C11)

CONT AT (D9)

CONT 7SP1-619-1 5-G-0089S02 (B15)

MONITOR DRAIN FW DO2 & CP SIGNED & DATED ELECTRONICALLY 35 INCORPORATED: EC# 67999 R3 (D17) 36 INCORPORATED: EC# 74122 (C5,D5)

SIGNED & DATED ELECTRONICALLY 37 SIGNED ELECTRONICALLY 8MD2-487-1 5-G-0185 S04 FLOW DIAG. YARD DUCTBANK SUMPS DRAINAGE SYS 5-G-0185 S03 FLOW DIAG. YARD DUCTBANK SUMPS DRAINAGE SYS 5-G-0185 S02 FLOW DIAG. YARD DUCTBANK SUMPS DRAINAGE SYS 5-G-0185 S01 FLOW DIAG. YARD DUCTBANK SUMPS DRAINAGE SYS CON'T BELOW @ L18 REFERENCE DRAWINGS CON'T FROM J18 INCORPORATED: EC# 79281 (C6-C8,J18,L18) 5-G-0185 S04 (D8)

SUMP COLLECTION MD FROM CABLE VAULT CONN FLUSH A

6422 PI 38 SIGNED ELECTRONICALLY 8MD*-572-1 INCORPORATED: EC# 89462 (M15-M16,N17) 1C-NNS AIR COMPRESSOR SEE (E7)

FOR CONT.

8MD-H97-1

\\

t I

I