ML20071D678

From kanterella
Revision as of 18:08, 23 May 2020 by StriderTol (talk | contribs) (StriderTol Bot insert)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Forwards Final Deficiency Rept Re Safety Injection Tanks - safe-end Indications
ML20071D678
Person / Time
Site: Satsop
Issue date: 03/07/1983
From: Leddick R
WASHINGTON PUBLIC POWER SUPPLY SYSTEM
To:
NRC
Shared Package
ML20071D684 List:
References
GO3-83-196, NUDOCS 8303110298
Download: ML20071D678 (1)


Text

. .

Washington Public Power Supply System B,x 1223 Elma, Washington 98541 (206)482-4428 Docket No. 50-508 March 7, 1983 G03-83-196 Document Control Desk U. S. Nuclear Regulatory Commission Washington, D. C. 20555

Subject:

POTENTIAL 10CFR50.55(e) DEFICIENCY SAFETY INJECTION TANKS - SAFE-END INDICATIONS (D/N #23)

Attached is a copy of the final report provided to Region V concerning a potential 10CFR50.55(e) deficiency associated with the subject con-dition. '

Should you have any questions or desire further information, please contact me directly.

C 99aD R. S. Leddick (760)

Program Director, WNP-3 DRC:nj Attachment cc: J. Adams - NESCO, wo/a D. Smithpeter - BPA, wo/a Ebasco - New York, wo/a WNP-3 Files - Richland, wo/a C303110298 8303' 0 7 --

PDR ADOCK 05000500PDR g -

_ - - . ._ . . _ . . _ _ _ --_ -