Text
_ _ _ _ _ _ _ _ _ _ _ _ _
G- vga Peer Cori cry 323 P4 ctrmt Avu Ate'a Gear g a ?C';'
Te* rho o 404 5"O C5; 6 M1 ! r r; Ad? ens Post Of f ce Bog 45%
A"arta Gc;org a 30352 L Georgia Power L T.Gucwa + < <,
cr a um agu-Pow c.rera on ceuem- . NED-83-302
\
May 20, 1983 Director of Nuclear Reactor Regulation Attention: br. John F. Stolz, Chief Operating Reactors Branch No. 4 Division of Licensing U. S. Nuclear Regulatory Commission Washington, D. C. 20555 NRC DOCKETS 50-321, 50-366 ,
OPERATItC LICENSES DPR-57, FFF-5 EDWIN I. HATCH NUCLEAR PLANT UNITS 1, 2 RESPONSE TO THE I&E BULLETIN 79-01B SAFETY EVALUATION REPORT AND THE EQUIPENT QUALIFICATION RULE Gentlemen:
By letter dated March 31, 1983, the NRC transmitted to Georgia Power Company (GPC) its Safety Evaluation Reports (SERs) and Technical Evaluation Reports (TERs) for environmental qualification of safety-related electrical equipment at Plant Hatch Units 1 and 2. That letter requested GPC to provide a response by May 20, 1983, addressing the final plans for replacement or qualification of all TER category I.B, II.A, II.8, and IV equipment items at Plant Hatch. In addition, that letter reaffirmed the requirement in 10 CFR 50.49(g) for a response by May 20, 1983, providing GPC's commitments for completion of the electrical equipment qualification program.
The enclosed volumes (one for each Plant Hatch unf t) contain the GPC responses to these requests. Each volume contains lists of all electrical equipment important to safety categorized according to qualification status. In addition, clarifications and information for items in TER category II.C are provided, since this information was not included as part of GPC's thirty-day SER/TER response (dated May 6,1983).
The qualification plan detailed in this response meets the 10 CFR 50.49(g) deadlines (second refueling outage after March 31, 1982, and not later than March 31, 1985) for final qualification of equipment within the I&E Bulletin 79-01B scope, barring any unforeseen implementation problems.
There fore, GPC has no plans for future submittals to the NRC regarding 4
roo607o224 esosao PDR ADOCK 05000321
[
h' 0
To4 b [' P' P PDR
\\n
_ . - - - _ _ _ - _ _ _ _ _ _ _ _ __ )
Georgia Power d Director of Nuclear Reactor Regulation Attention: Mr. John F. Stolz, Chief Operating Reactors Branch No. 4 May 20, 1983 Page Two electrical equipment qualification. However, GPC will inform the NRC of any major deviation from the present Plant Hatch program schedule which could potentially result in a failure to meet the required deadlines.
Very truly yours, ef.E%
L. T. Gucwa CBS/mb xc: H. C. Nix, Jr.
J. P. O'Reilly Senior Resident Inspector mm
~~
l l
9 GEORGIA POWER COMPANY EDWIN 1. HATCH NUCLEAR PLANT - UNIT 1 DOCKET: 50-321 O
ENVIRONMENTAL QUALIFICATION OF CLASS 1E EQUIPMENT MAY 20, 1983 RESPONSE TO NRC SAFETY EVALUATION REPORT AND RULE 10CFR50.49 REVISION 0, MAY 20, 1983 (x
e
l GEORGIA POWER COMPANY EDWIN 1. HATCH NUCLEAR PLANT - UNIT 1 DOCKET: 50-321 MAY 20, 1983 RESPONSE TO NRC SAFETY EVALUATION REPORT AND RULE 10CFR50.49 TABLE OF CONTENTS Section A - Introduction
() Section B - Environmentally Qualified Equipment List Introduction Equipment List Section C - Equipment Requiring Qualification Clarifications Introduction Clarification Section D - Open Item Equipment List Introduction Equipment List m
O SECTION A INTRODUCTION SCOPE This submittal is provided by Georgia Power Company as the May 20, 1983 Response to the Nuclear Regulatory Commission (NRC) Safety Evaluation Report (SER) for Environmental Qualification of Safety Related Electrical Equipment (I.E.
Bulletin 79-01B) and the Rulemaking 10 CFR 50.49 for Edwin I. Hatch Nuclear Plant - Unit 1.
BACKGROUND On October 31, 1980, Georgia Power Company submitted to the NRC an Environmental Qualification submittal in response to I. E. Bulletin 79-01B for Edwin I. Hatch Nuclear Plant - Unit 1.
On February 1,1981, Georgia Power Company submitted revision 1 of the Environmental Qualification submittal in response to I. E. Bulletin 79-01B.
This revision included a response to Supplement B of the bulletin regarding TMI Action Plan Equipment and Equipment required to achieve to I. E. Bulletin 79-01B.
O On February 17, 1981, Georgia Power Company submitted revision 2 of the Environmental Qualification submittal in response to I. E. Bulletin 79-01B.
Based on review of Georgia Power Company's submittals conducted by Franklin Research Center (FRC), the NRC issued a Safety Evaluation Report (SER) on June 16, 1981.
, Georgia Power Company provided a response to the SER as part of revision 3 of the Environmental Qualification submittal to I. E. Bulletin 79-01B issued on September 14, 1981.
On February 10, 1982, Georgia Power Company provided the NRC with additional qualification information. The NRC requested this information in order for FRC to complete the review of the Environmental Qualification submittal provided by Georgia Power Company.
The Safety Evaluation Report (SER) together with a Technical Evaluation Report (TER), was transmitted to Georgia Power Company by letter, dated March 31, 1983, from Mr. John F. Stolz, Chief Operating Reactors Branch No. 4, Division of Licensing to Mr. J. T. Beckham, Jr., Vice President Nuclear-Generation Georgia Power Company.
On May 6, 1983, Georgia Power Company submitted the required Thirty (30) Day Response to the NRC Safety Evaluation Report.
i O 1
' '~^
SUBMITTAL 0 This submittal is comprised of four (4) major sections; Section A -
Introduction, Section B - Environmentally Qualified Equipment List, Section C -
Equipment Requiring Qualification Clarifications, and Section D - Open Item Equipment List.
Section B of this submittal provides a list of safety related equipment which Georgia Power Company considers environmentally qualified.
Section C of this submittal provides clarifications and additional information required to address the NRC discrepancies listed for equipment in NRC Qualification Category II.c. Clarifications for equipment in NRC Qualification Categories I.b, II.a. and II.b were provided in the Thirty (30) Day Response to the NRC Safety Evaluation Report.
Section D of this submittal provides a list of safety related equipment which Georgia Power Company considers to have open items concerning Environmental
( Qualification. A Corrective Action is provided for each equipment item included
- in this list.
l Justifications for Continued Operation for the Equipment having open items concerning qualification were submitted in the Thirty (30) Day Response to the Safety Evaluation Report or were included in previous I. E. Bulletin 79-01B submittals and reaffirmed in the Thirty (30) Day Response.
DISCUSSIONS CONCERNING RULEMAKING 10 CFR 50.49 Georgia Power Company's previous I.E. Bulletin 79-01B submittals have been reviewed against the requirements of paragraphs (a) and (b) of 10 CFR 50.49 and it is concluded that Georgia Power Company's program for Qualifying Electrical Equipment includes all harsh environment equipment (non-safety related as well as safety related equipment) that is relied upon to remain functional during and following a High Energy Line Break (HELB) or Loss of Coolant Accident (LOCA).
A systematic review of the control and power circuit for each component which is associated with equipment covered in I.E. Bulletin 79-01B was completed. Each circuit was reviewed to assure that the failure of any component within the circuit, which is located in a harsh environment, could not prevent the I.E.
Bulletin 79-01B component from serving its safety related function.
l Post-accident monitoring Equipment was included in Georgia Power Company's I.E.
Bulletin 79-01B submittals to the extent that it was identified using the methodology described above. Georgia Power Company is currently negotiating a schedule with the NRC staff for responding to Supplement 1 to NUREG-0737 (Reference Generic Letter 82-33). A portion of the response to the supplement will compare Hatch Nuclear Plant - Unit I with the " requirements" of Regulartory Guide 1.97 Revision 2 and will justify any exceptions to the Regulatory Guide which are taken. In those cases where deviations cannot be justified, the Regulatory Guide " requirements" will be met. If the instrument is located in a harsh environment and installed prior to May 23, 1980, qualification of the instrument will be evaluated against the DOR Guidelines. If the instrument was O installed after May 23, 1980, qualification will be evaluated against NUREG-0588 Category I or the 10CFR50.48 rule as applicable.
l
SECTION B O ENVIRONMENTALLY QUALIFIED EQUIPMENT LIST INTRODUCTION This section provides, per the requirements of 10CFR 50.49. Paragraph (g), a list of electrical equipment important to safety, which Georgia Power Company considers environmentally qualified.
The environmentally qualified equipment is identified by the TER Equipment Item l Number (if applicable) and associated Plant Identification Number, followed by the Equipment Location, Equipment Description and the Equipment Service.
O i
O
m x-TABLE B-1 ENVIRONMENTALLY QUALIFIED EQUIPMENT LIST TER EQUIPMENT ITEM NO: 1 Plant ID: T48-MOV F013A,B Motorized Valve Actuator Located in the Reactor Building, Elev. 130' 0" Limitorque Model SMB, AC Service Class H Insulation Se rvice: Nitrogen Makeup Isolation TER EQUIPMENT ITEM NO: 4 Plant ID: Ell-MOV F015A Motorized Valve Actuator Located in the Pipe Penetration Room Limitorque Model SB3, AC Service, Class H Insulation Service: LPCI Discharge Isolation TER EQUIPMFNT ITEM No: 5 Plant ID: Ell-MOV F028A,B '
Motorized Valve Actuator Located in the Torus Room Limitorque Model SMB, AC Service, Class B Insulation Service: Torus Spray Isolation TER EQUIPMENT ITEM NO: 7 s/
m Plant ID: Ell-MOV F023 Motorized Valve Actuator Located in the Reactor Building, Elev. 185' 0" Limitorque Model SMB, DC Service, Class B Insulation Service: Vessel Head Spray Header Isolation TER EQUIPMENT ITEM NO: 8 Plant ID: B21-MOV F016 Motorized Valve Actuator Located in-the Containment Limitorque Model SMB, AC Service, Class H Insulation Service: Main Steam Line Drain Isolation TER EQUIPMENT ITEM NO: 9 Plant ID: E51-MOV F007 Motorized Valve Actuator Located in the Containment Limitorque Model SMB, AC Service, Class H Insulation Service: Steam Supply Isolation TER EQUIPMENT ITEM NO: 11 Plant ID: E21-K3V F001A,B Motorized Valve Actuator Located in the Northeast and Southeast Corner Rooms simitorque Model SMB, AC Service, Class B Insulation Service: Core Spray Pump Suction Isolation O
d
TER EQUIPMENT ITEM NO: 12 Plant ID: Ell-MOV F017A Motorized Valve Actuator Located in the Pipe Penetration Room Linitorque Model SMB, AC Service, Class B Insulation Service: Containment Spray Discharge Isolation TER EQUIPMENT ITEM NO: 12 Plant ID: Ell-MOV F017B Motorized Valve Actuator Located in the Pipe Penetration Room Limitorque Model SMB, AC Service, Class H Insulation Service: Containeent Spray Discharge Isolation TER EQUIPMENT ITEM NO: 14 Plant ID: E41-F0V F002 Motorized Valve Actuator Located in the Containeent Limitorque Model SMB, AC Service, Class H Insulation Service: Steam Supply Isolation TER EOUIPMENT ITEM NO: 17 Plant ID: E41-MOV F004 Motorized Valve Actuator Located in the High Pressure Coolant Injection Room Limitorque Model SMB, DC Service, Class B Insulation Se rvice: Condensate StoraFe Tank to Pump Suction Isolation
(N
( ,) TER EQUIPMENT ITEM NO: 17 Plant ID: E41-MOV F042 Motorized Valve Actuator Located in the High Pressure Coolant Injection Room Limitorque Model SMB, DC Service, Class B Insulation Service: HPCI Pump Suction Isolation from Torus TER EQUIPMENT ITEM NO: 18 Plant ID: P41-MOV F050 Motorized Valve Actuator Located in the Torus Room Limitorque Model SMB, AC Service, Class H Insulation Service: Service Water Isolation to Drywell Coolers TER EQUIPMENT ITEM NO: 18 i
Plant ID: P41-MOV F049 Motorized Valve Actuator Located in the Torus Room i
Limitorque Model SMB, AC Service, Class H Insulation Service: Service Water Isolation to Drywell Coolers TER EQUIPMENT ITEM NO: 18 Plant ID: Ell-MOV F119A,B Motorized Valve Actuator Located in the Torus Room Limitorque Model SMB, AC Service Service: Residual Heat Removal Heat Exchanger Bypass TER EQUIPMENT ITEM NO: 19 Plant ID: Ell-MOV F016A,B Motorized Valve Actuator Located in the Pipe Penetration Room
[N_-)/ Limitorque Model SMB, AC Service, Class B Insulation Service: Containment Spray Discharge Isolation
p O TER EQUIPMENT ITEM NO: 20 Plant ID: Ell-MOV F049 Motorized Valve Actuator Located in the Torus Roce Limitoraue Model SMB, DC Service, Class B Insulation Service: Residual Heat Recoval Discharge to Radwaste Isolation TER EQUIPMENT ITEM NO: 20 Plant ID: E51-MOV F013 Motorized Valve Actuator Located in the Torus Room Limitorque Model SMB, DC Service, Class B Insulation Service: Reactor Core Isolation Cooling Pump Discharge Isolation TER EQUIPMENT ITEM NO: 22 Plant ID: E41-MOV F059 Motorized Valve Actuator Located in the High Pressure Coolant Injection Room Linitorque Model SMB, DC Service, Class H Insulation Service: HPCI Pump Discharge Isolation to Barometric Condenser TER EQUIPMENT ITEM NO: 22 Plant ID: E21-MOV F015A,B Motorized Valve Actuator Located in the Northeast and Southeast Corner Roots Limitorque Model SMB, AC Service, Class B Insulation Service: Test Bypass Isolation
(
> [' l
\_-
h TER EQUIPMENT ITEM NO: 22 Plant ID: E21-MOV F031A,B Motorized Valve Actuator Located in the Northeast and Southeast Corner Rooms Limitorque Model SMB, AC Service, Class B Insulation Service: Core Spray Pump Minimum Flow Bypass Isolation TER EQUIPMENT ITEM NO: 23 Plant ID: Ell-MOV F027A,B Motorized Valve Actuator Located in the Torus Room Limitorque Model SMB, AC Service, Class B Insulation Service: Torus Spray Isolation TER EQUIPMENT ITEM NO: 23 Plant ID: Ell-MOV F024A,B Motorized Valve Actuator Located in the Torus Room Limitorque Model SMB, AC Sercice, Class B Insulation Service: Residual Heat Removal Test Line Isolation l TER EQUIPMENT ITEM No: 23 Plant ID: Ell-MOV F040 Motorized Valve Actuator Located in the Torus Room I Limitorque Model SMB, AC Service, Class B Insulation l Service: Residual Heat Removal Discharge to Radwaste Isolation TER EQUIPMENT ITEM NO: 23 7 ,3 Plant ID: Ell-MOV F073A,B L
' ) Motorized Valve Actuator Located in the Torus Room
# Limitorque Model SMB, AC Service, Class B Insulation l Service: Residual Heat Removal Service Water Pump Discharge Isolation
i O TER EQUIPMENT ITEM NO: 23 Plant ID: Ell-MOV F075A,E Motorized Valve Actuator Located in the Torus Room Limitorque Model SMB, AC Service, Class B Insulation Service: Residual Heat Removal Service Water Pump Discharge Isolation TER EQUIPMENT ITEM NO: 23 Plant ID: Ell-MOV F091A,B Motorized Valve Actuator Located in the Torus Room Limitorque Model SMB, AC Service, Class B Insulation Service: Residual Heat Removal Discharge to Residual Heat Removal Hx Isolation TER EQUIPMENT ITEM NO: 23 Plant ID: Ell-MOV F0140A,B Motorized Valve Actuator Located in the Torus Room Limitorque Model SMB, AC Service, Class B Insulation Service: HPCI Discharge to Residual Heat Removal Hx lsolation TER EQUIPMENT ITEM NO: 23 Plant ID: E41-MOV Flll Motorized Valve Actuator Located in the Torus Roon Linitorque Model SMB, AC Service, Class B Insulation Service: Vacuum Breaker Isolation I
TER EQUIPMENT ITEM NO: 23
(\ Plant ID: E41-MOV F104 Motorized Valve Actuator Located in the Torus Room Linitorque Model SMB, AC Service, Class B Insulation Service: Vacuum Breaker Isolation TER EQUIPMENT ITEM NO: 23 Plant ID: E51-MOV F105 Motorized Valve Actuator Located in the Torus Room Limitorque Model SMB, AC Service, Class B Insulation Service: Vacuum Relief Isolation l
TER EQUIPMENT ITEM NO: 23 Plant ID: E51-MOV F104 Motorized Valve Actuator Located in the Torus Room Limitorque Model SMB, AC Service, Class B Insulation Service: Vacuum Relief Isolation l TER EQUIPMENT ITEM NO: 24 l Plant ID: Ell-MOV F007A,B
! Motorized Valve Actuator Located in the Northeast and Southeast Corner Rooms Limitorque Model SMB, AC Service, Class B Insulation Service: RHR Pump Minimum Flow Bypass Isolation TER EQUIPMENT ITEM No: 24 Plant ID: Ell-MOV F006A,B,C D
., } Motorized Valve Actuator Located in the Northeast and Southeast Corner Rooms
# Limitorque Model SMB, AC Service, Class B Insulation Service: Residual Heat Removal Pump Suction Isolation
\-'
TER EQUIPMENT ITEM NO: 24 Plant ID: Ell-MOV F004A,B.C.D Motorized Valve Actuator Located in the Northeast and Southeast Corner Rooms Limitorque Model SMB, AC Service, Class B Insulation Service: Residual Heat Removal Pump Suction Isolation TER EQUIPMENT ITEM NO: 24 Plant ID: Ell-MOV F003A,B Motorized Valve Actuator Located in the Northeast and Southeast Corner Rooms Limitorque Model SMB, AC Service, Class B Insulation Service: Hx Discharge Isolation TER EQUIPMENT ITEM NO: 24 Plant ID: Ell-MOV F0llA,B Motorized Valve Actuator Located in the Northeast and Southeast Corner Rooms Limitorque Model SMB, AC Service, Class B Insulation Service: Residual Heat Removal Hx Drain to Torus Isolation TER EQUIPMENT ITEM NO: 24 Plant ID: Ell-MOV F015B Motorized Valve Actuator Located in the Pipe Penetration Room Limitorque Model SB3, AC Service, Class B Insulation Service: Low Pressure Coolant Injection Discharge Isolation TER EQUIPMENT ITEM NO: 24
('^'T s ,) Plant ID: Ell-MOV F026A,B Motorized Valve Actuator Located in the Northeast and Southeast Corner Rooms Limitorque Model SMB, AC Service, Class B Insulation Service: Residual Heat Removal Hx to RCIC Isolation TER EQUIPMENT ITEM NO: 24 Plant ID: Ell-MOV F048A,B Motorized Valve Actuator Located in the Northeast and Southeast Corner Rooms Limitorque Model SMB, AC Service, Class B Insulation
- Service
- Residual Heat Removal Hx to Bypass Isolation TER EQUIPMENT ITEM NO: 24 i
i Plant ID: Ell-MOV F047A,B Motorized Valve Actuator Located in the Northeast and Southeast Corner Rooms
, Limitorque Model SMB, AC Service, Class B Insulation l Service: Residual Heat Removal Hx Inlet Isolation TER EQUIPMENT ITEM NO: 24 Plant ID: Ell-MOV F068A,B Motorized Valve Actuator Located in the Northeast and Southeast Corner Rooms Limitorque Model SMB, AC Service, Class B Insulation Service: Residual Heat Removal Service Water Flow Control l 0>
's--
r'~N TER EOUIPMENT ITEM No: 24 Plant ID: Ell-MOV F103A,B Motorized Valve Actuator Located in the Northeast and Southeast Corner Rooms Limitorque Model SMB, AC Service, Class H Insulation Service: Residual Heat Removal Hx Inlet Isolation TER EOUIPMENT ITEM No: 25 Plant ID: P70-A0V F004 Solenoid Valve Located in the Reactor Building Elev. 130' 0" ASCO Model NP206-381-3F Service: Drywell Pneumatic Isolation TER EOUIPMENT ITEM No: 25 Plant ID: P70-A0V F005 Solenoid Valve Located in the Reactor Building, Elev. 130' 0" ASCO Model NP206-380-3F Service: Drywell Pneumatic Isolation TER EQUIPMENT ITEM NO: 26 Plant ID: E11-A0V F122A B Solenoid Valve Located in the Containment ASCO Model NP206-832-3VF Service: Testable Check By-pass l / TER EQUIPMENT ITEM NO: 27 l\ -
Plant ID: Ell-A0V F051A,B l
Solenoid Valve Located in the Torus Room ASCO Model NP206-380-3F Service: HPCI Discharge to RHR Hx Isolation TER EOUIPMENT ITEM NO: 28 Plant ID: P33-A0V F003 Solenoid Valve Located in the Reactor Building Elev 158' 0" ASCO Model NP206-381-5F Se rvice: H2 and 0 Isolation 2
l' TER EQUIPMENT ITEM NO: 28 Plant ID: B31-A0V F020 Solenoid Valve Located in the Reactor Building, Elev 158' 0" ASCO Model NP206-380-3F Service: Reactor Water Sample Isolation TER EQUIPMENT ITEM NO: 28 Plant ID: P33-A0V F015 Solenoid Valve Located in the Torus Room ASCO Model NP206-380-5F I Service: H and 0 Torus Isolation 2 2 TER EQUIPMENT ITEM NO: 28 7s Plant ID: P33-A0V F014 Solenoid Valve Located in the Torus Room
('
ASCO Model NP206-380-5F Service: H and 0 Drywell Isolation 2 2 l
TER EQUIPMENT ITEM NO: 28 Plant ID: P33-A0V F012 Solenoid Valve Located in the Torus Room ASCO Model NP206-380-5F Service: H and 0 Return to Drywell Isolation 2 2 TER EQUIPMENT ITEM NO: 28 Plant ID: P33-A0V F011 Solenoid Valve Located in the Reactor Building Elev. 158' 0"
- ASCO Model NP206-380-5F Service
- H2 and 0 Drywell Isolation 2
TER EQUIPMENT ITEM NO: 28 Plant ID: P33-A0V F007 Solenoid Valve Located in the Torus Roen ASCO Model NP206-381-5F Service: H2 and 02 Torus Isolation TER EQUIPMENT ITEM NO: 28 Plant ID: P33-A0V F006 Solenoid Valve Located in the Torus Room ASCO Model NP206-381-5F Service: H and 0 Drywell Isolation 2 2
) TER EQUIPMENT ITEM NO: 28 Plant ID: P33-A0V F004 Solenoid Valve Located in the Torus Room ASCO Model NP206-381-5F Se rvice: H and Oy Return to Drywell Isolation 2
TER EQUIPMENT ITEM NO: 28 Plant ID: P70-A0V F003 Solenoid Valve Located in the Reactor Building, Elev. 126' 0" ASCO Model NP206-380-3F Service: Drywell Pneumatic Isolation TER EQUIPMENT ITEM NO: 28 Plant ID: P70-A0V F002 Solenoid Valve Located in the Torus Room ASCO Model NP206-380-3F Service: Drywell Pneumatic Isolation TER EQUIPMENT ITEM NO: 29 Plant ID: P41-A0V F039A B l Solenoid Valve Located in the Southeast Corner Room ASCO Model NP206-380-3FM0 Service: Residual Heat Removal / Core Spray Pump Room Cooler Isolation t
TER EQUIPMENT ITEM NO: 29
-~s Plant ID: P41-A0V F037A,B.C.D I Solenoid Valve Located in the Northeast and Southeast Corner Rooms
! ASCO Model NP206-380-3F Service: Residual Heat Removal Pump Room Cooler Isolation
)
TER EQUIPMENT ITEM NO: 29 Plant ID: P41-A0V F036A B Solenoid Valve Located in the Northeast Corner Room ASCO Model NP206-380-3F i Service: Residual Heat Removal / Core Spray Pump Room Cooler Isolation TER EQUIPMENT ITEM NO: 29 Plant ID: P41-A0V F035A,B Solenoid Valve Located in the HPCI Room ASCO Model NP206-380-3F Service: High Pressure Coolant Injection Room Cooler Isolation TER EQUIPMENT ITEM No: 30 Plant ID: T48-A0V F332A,B Solenoid Valve Located in the Torus Room ASCO Model NP206-380-6RF Service: Torus Bypass Isolation TER EQUIPMENT ITEM No: 30 Plant 1D: T48-A0V Fil3
, Solenoid Valve Located in the Torus Room ASCO Model NP206-380-3F Service: Drywell Nitrogen Makeup Isolation
( TER EQUIPMENT ITEM NO: 30 Plant ID: T48-A0V Fil4 i Solenoid Valve Located in the Torus Room ASCO Model NP206-380-3F Service: Drywell Nitrogen Makeup Isolation
- TER EQUIPMENT ITEM NO: 30 Plant ID: T48-A0V F115 Solenoid Valve Located in the Torus Room I
ASCO Model NP206-380-3F Service: Torus Nitrogen Makeup Isolation TER EQUIPMENT ITEM NO: 30 Plant ID: T48-A0V Fil6 Solenoid Valve Located in the Torus Room ASCO Model NP206-380-3F Service: Torus Nitrogen Makeup Isolation TER EQUIPMENT ITEM No: 30 Plant ID: T48-A0V F321
( Solenoid Valve Located in the Torus Room j ASCO Model NP206-380-3F Service: Drywell Nitrogen Makeup Isolation l
l 'JO~.
i
- . _ - = _ _ _ . _ . . - . . _ _ _ .
O TER EQUIPMENT ITEM No: 30 Plant ID: T48-A0V F322 Solenoid Valve Located in the Torus Room ASCO Model NP206-380-3F Service: Drywell Nitrogen Makeup Isolation TER EQUIPMENT ITEM NO: 30 Plant ID: T48-A0V F325 Solenoid Valve Located in the Torus Room
- ASCO Model NP206-380-3F Service: Torus Nitrogen Makeup Isolation TER EQUIPMENT ITEM No: 30 Plant ID: T48-A0V F327 Solenoid Valve Located in the Torus Room ASCO Model NP206-380-3F Service: Torus Nitrogen Makeup Isolation TER EQUIPMENT ITEM NO: 30 Plant ID: T48-A0V F333A,B Solenoid Valve Located in the Torus Room -
ASCO Model NP206-380-6RF Service: Torus Bypass Isolation
~
/ TER EQUIPMENT ITEM NO: 31
' ('~'}
/ Plant ID: Cll-SV F009 Solenoid Valve Located in the Reactor Building, Elev. 130' 0" ASCO Model NP8323A22E Service: Scram Volume Drain
.TER EQUIPMENT ITEM NO: 32,40 Plant ID: T41-A0V F023A,B .. .
Solenoid Valve Located in the Reactor Building, Elev. 164' 0" '
ASCO Model NP8321A2E Service: Refueling Floor Exhaust Fan Discharge Isolation TER EQUIPMENT ITEM NO: 32 Plant ID: T41-A0V F032A,B Solenoid Valve Located in the Reactor Building, Elev. 164' 0" ASCO Model NP206-380-5F Service: Reactor Building, Vent Discharge to Standby Gas Treatment TER EQUIPMENT ITEM NO: 33 Plant ID: P33-SV F005A,B C.D Solenoid Valve Located in the Reactor Building, Elev. 158' 0
Target Rock Model 73K003 Service: Fission Products Monitoring Isolation TER EQUIPMENT ITEM NO: 34
, Plant ID: T48-SV Fil8A,B Solenoid Valve Located in the Reactor Building, Elev. 130' 0"
(}/
s_, Target Rock Model 73K003 Service: Drywell/ Torus Nitrogen Makeup Isolation l
. 7- . - . .. . . -- - - - -- . _. . - - - _ - _ .
'v s-J TER t s9IPMENT ITEM No: 35 Plant ID: E41-SV F053 Solenoid Valve Located in the High Pressure Coolant Injection Room Target Rock Model 75F008 Service: Condensate Draia Pot to Barometric Condenser Isolation TER EQUIPMENT ITEM NO: 36 Ple,nt ID: Ell-SV E074A,B g Solenoid Valve Located in the Torus Room Target Rock Model 73K004 Service: RHR Service Water to Dryvell Isolation TER EQUIPMENT ITEM NO: 37 1 Plant ID: T48-SV F338 Solenoid Valve Located in the Torus Room Target Rock Model 73K002 Service: Torus Bypass Isolation TER EQUIPMENT ITEM NO: 37
- Plant ID: T48-SV F339 Solenoid Valve Located in the Torus Room Target Rock Model 73K002 Service: Torus Bypass Isolation n'
( TER EQUIPMENT ITEM No: 38 Plant ID: T48-SV F340 Solenoid Valve' Located in the Reactor Building, Elev. 185' 0" Target Rock Model 73K002 Service: ' Torus Bypass Isolation
! TER EQUIPMENT ITEM NO: 38 Plant ID: T48-SV F341 Solenoid Valve Located in the Reactor' Building Elev. 185' 0" Target Rock Model 73K002 Service: Torus Bypass Isolation TER EQUIPMENT ITEM NO: 39 f
Plant ID: B21-A0V F013A C.E.F.J,K,L Solenoid Valve Located in the Containment Target Rock Model 1/2 SMS-A-01-1 Service: ADS TER EQUIPMENT ITEM NO: 40 Plant ID: G11-A0V F003 Solencid Valve Located in the Torus Room ASCO Model NP8321A2E Service: Drywell Floor Drain Sump Discharge Isolation O
w *.
)
y .- _ c -
- y. - - -.
l ,
Y
_f\ !,
TER EQUIPMENT ITEM NO: 40 Plant ID: T41-ADV F031A,B Solenoid Valve Located in the Reactor Building, Elev. 164' 0"
,ASCO Mo ed l NP8321A2EL Service: Reactor Building Exhaust Fan Discharge Isolation TER EQUIPMENT ITEM NO: 40 Plant ID: T41-A0V F044A,B Solenoid. Valve Located in the Reactor Building, Elev. 164' 0" ASCO Model NP8321A2E Srtvice: Reactor Building Exhaust, Fan Discharge Isolation TER EQUIPMENT ITEM NO: 40 Plant ID: E21-A0V F019A,B Solenoid Valve Located in the Torus Room ASCO Model NP8321A6E Service: Torus to Core Spray Purp Suction Isolation TER EQUIPMENT ITEM NO: 40 Plant ID: E51-A0V F003 Solenoid Valve Located in the Torus Room ASCO Model NP8321A2E Service: Torus Discharge Isolation to RCIC Pucp
/~~'Ni i TER EQUIPMENT ITEM NO: 40 Plant ID: E41-A0V F051 Solenoid Valve Located in the Torus Room u ASCO Model NP8321A2E Service: Torus Discharge Isolation to HPCl Pump s , TER EQUIPMENT ITEM NO: 41 Plant ID: T46-A0V F001A,B Solenoid Valve Located in the Reactor Building, Elev. 164'f0" ASCO Model NP831656E Service: Filter Suction Isolation TER EQUIPMENT ITEM NO: e
, Plant ID: T46-A0V F&i2A, Solenoid Valve lec15, O v.he Reactor Building, Elev. 164' 0" ASCO Model NP831'jf7; .
Service: Filter Lischarge Jeolation TER EQUIPMENT ITEM NO: 42 Plant ID: G51-A0V F011 Solenoid Valve Located in the Torus Room ASCO Model NP831654E Service: Torus Water Cleanup Isolation
/N ,
b 4
d TER EOUIPMENT ITEM NO: 42 Plant ID: G51-A0V F012 Solenoid Valve Located in the Torus Room ASCO Model NP831654E Service: Torus Water Cleanup Isolation TER EQUIPMENT ITEM No: 43 Plant ID: T48-A0V F326 Solenoid Valve Located in the Torus Room ASCO Model NP8316A74E Service: Torus Discharge Isolation TER EQUIPMENT ITEM NO: 43 Plant ID: T48-A0V F324 Solenoid Valve Located in the Torus Room ASCO Model NP8316A74E Service: Purge Isolation to Torus TER EQUIPMENT ITEM NO: 43 Plant ID: T48-A0V F318 Solenoid Valve Located in the Torus Room ASCO Model NP8316A74E Service: Torus Discharge Isolation b TER EQUIPMENT ITEM No: 43
\s_ l Plant-ID: T48-A0V F309 Solenoid Valve Located in the Torus Room ASCO Model NP8316A74E Service: Purge Isolation to Torus TER EQUIPMENT ITEM NO: 43 Plant ID: T48-A0V F308 Solenoid Valve Located in the Torus Room ASCO Model NP8316A74E l Service: Purge Isolation to Drywell TER EQUIPMENT ITEM NO: 43 Plant ID: T48-A0V F307 Solenoid Valve Located in the Torus Room ASCO Model NP8316A74E Service: Purge Isolation to Drywell TER EQUIPMENT ITEM NO: 43 Plant ID: E11-A0V F065A,B,C,D Solenoid Valve Located in the Torus Room ASCO Model NP831664E Service: RHR Pump Suction Isolation s_.-
l
-x j TER EQUIPMENT ITEM NO: 44 Plant ID: Gil-A0V F020 Solenoid Valve Located in the Torus Room ASCO Model NP8320A184E Service: Drywell Equipment Drain Sump Discharge Isolation TER EQUIPMENT ITEM NO: 44 Plant ID: Gil-A0V F019 Solenoid Valve Located in the Torus Room ASCO Model NP8320A184E Service: Drywell Equipment Drain Sump Discharge Isolation TER EQUIPMENT ITEM NO: 44 Plant ID: Gil-ACV F004 Solenoid Valve Located in the Torus Room ASCO Model NP8320A184E Service: Drywell Floor Drain Sump Discharge Isolation TER-EQUIPMENT ITEM No: 45 Plant ID: P41-A0V F066 Solenoid Valve Located in the Torus Room ASCO Model NP8344A73E Se rvice: Plant Service Water Isolation to Reactor Building
( ')
TER EQUIPMENT ITEM NO: 45 Plant ID: P41-A0V F067 Solenoid Valve Located in the Torus Roon ASCO Model NP8344A73E Service: Plant Service Water Isolation to Reactor Building TER EQUIPMENT ITEM NO: 46 Plant ID: Cll-SV Dll7 Solenoid Valve Located in the Reactor Building, Elev. 130' 0" ASCO Model HVA-90-405 Service: Scram TER EQUIPMENT ITEM NO: 46 Plant ID: Cll-SV D118 Solenoid Valve Located in the Reactor Building, Elev. 130' 0" r ASCO Model HVA-90-405 Service: Scram TER EQUIPMENT ITEM NO: 47 Plant ID: B31-A0V F019 Solenoid Valve Located in the Containment ASCO Model NP8320A187E Service: Reactor Water Sample Isolation
- + --- ,,--- ., ,. -
)
b TER EOUIPMENT ITEM NO: 47 Plant ID: E11-A0V F053A,B Solenoid Valves Located in the Northeast and Southeast Corner Roons ASCO Model NP206-380-3F Service: RHR Ex Condenser Discharge Isolation TER EQUIPMENT ITEM NO: 47 Plant ID: E41-A0V F029 Solenoid Valve Located in the HPCI Room ASCO Model NP206-381-3F Service: Steam Pot Drain Isolation TER EQUIPMENT ITEM NO: 47 Plant ID: P33-A0V F002 Solenoid Valve Located in the Reactor Building, Elev. 185' 0" ASCO Model NP206-381-3F Service: H and 0 Drywell Isolation 2 2 TER EQUIPMENT ITEM NO: 47 Plant ID: P33-A0V F010 Solenoid Valve Located in the Reactor Building, Elev. 185'0" ASCO Model NP206-380-3F Service: H and 0 Drywell Isolation 2 2 TER EOUIPMENT ITEM NO: 47 4
~- Plant ID: F41-A0V F040A,B J
Solenoid Valves Located in the RCIC (SW) Corner Room ASCO Model NP206-380-3F Service: RCIC Room Cooler Isolation TER EQUIPMENT ITEM NO: 47 Plant ID: T41-A0V F011B Solenoid Valve Located in the Reactor Building, Elev. 185' 0" ASCO Model NP8321A2E Service: Reactor Building Supply Fan Discharge Isolation i
TER EQUIPMENT ITEM NO: 47 Plant ID: T46-A0V F005 Solenoid Valve Located in the Reactor Building, Elev. 164' 0" ASCO Model NP831656E Service: System Discharge to Main Stack TER EQUIPMENT ITEM NO: 47 Plant ID: T48-A0V F104 Solenoid Valve Located in the Reactor Building, Elev. 130' 0" ASCO Model NP206-380-3F Service: Drywell/ Torus Nitrogen Makeup Isolation O
O TER EQUIPMENT ITEM NO: 47 Plant ID: T48-A0V F319 Solenoid Valve Located in the Reactor Building, Elev. 185' 0" ASCO Model NP8316A74E Service: Drywell Discharge Isolation TER EQUIPMENT ITEM NO: 47 Plant ID: T48-A0V F320 Solencid Valve Located in the Reactor Building, Elev. 185' 0" ASCO Model NP8316A74E Service: Drywell Discharge Isolation TER EQUIPMENT ITEM NO: 47 Plant ID: T48-A0V F334A,B Solenoid Valve Located in the Reactor Building, Elev. 185' 0" ASCO Model NP8320A184 EMS Service: Drywell Bypass Isolation TER EQUIPMENT ITEM NO: 47 Plant ID: T48-AOV F335A,B Solenoid Valves Located in the Reactor Building, Elev. 185' 0" ASCO Model NP8320A184 EMS Service: Drywell Bypass Isolation
[}
N- /
TER EQUIPMENT ITEM NO: 47 Plant ID: E41-A0V F026 Solenoid Valve Located in the HPCI Room ASCO Model NP206-381-3F Service: Condenser Pump Discharge Drain Isolation TER EQUIPMENT ITEM NO: 47 Plant ID: E41-AOV F028 Solenoid Valve Located in the HPCI Room ASCO Model NP206-381-3F Service: Steam Pot Drain Isolation TER EQUIPMENT ITEM NO: 48 Plant ID: E41-SV F122 Solenoid Valve Located in the Torus Room Valcor Model V5265295 Service: Sample Return Isolation to Torus TER EQUIPMENT ITEM NO: 48 Plant ID: E41-SV F121 Solenoid Valve Located in the Torus Room valcor Model V5265295 Service: Sample Return Isolation to Torus O
O TER EQUIPMENT ITEM NO: 49 Plant ID: B21-A0V F028A,B,C,D Solenoid Valves Located in the Pipe Chase Automatic Valve Model 4988-15 Service: Main Steam Line Isolation TER EQUIPMENT ITEM NO: 49 Plant ID: B21-A0V F022A,B,C,D Solenoid Valves Located in the Containment Automatic Valve Model 4988-15 Service: Main Steam Line Isolation TER EQUIPMENT ITEM No: 50 Plant ID: G51-A0V F021 Solenoid Valve Located in the Northeast Corner Room ASCO Model NP206-380-3F Service: Torus Water Makeup Isolation TER EQUIPMENT ITEM No: 50 Plant ID: G51-A0V F013 Solenoid Valve Located in the Northeast Corner Room ASCO Model NP206-380-3F Service: Torus Water Makeup Isolation
, TER EQUIPMENT ITEM NO: 51 (Q) ,
Plant ID: E21-A0V F006A,B Solenoid Valve Located in the Containment ASCO Model NP8344A73E Service: Core Spray Pump Discharge Isolation TER EQUIPMENT ITEM NO: 51 Plant ID: E21-A0V F037A,B Solenoid Valve Located in the Containment ASCO Model NP8344A73E l
Service: Core Spray Pump Discharge Isolation l TER EQUIPMENT ITEM NO: 52 j Plant ID: B21-SV Fill r
Solenoid Valve Located in the Reactor Building, Elev. 130' 0" Valcor Model V5266040 Service: Sample Isolation from Jet Pump TER EQUIPMENT ITEM NO: 52 Plant ID: B21-SV Fil2 Solenoid Valve Located in the Reactor Building, Elev. 130' 0"
- Valcor Model V5266040 Service
- Sample Isolation from Jet Pump l
v
)
i l
t
}
TER EQUIPMENT ITEM No: 53 Plant ID: E21-A0V F037A Limit Switches Located in the Containment Namco Model EA180-31302 Service: E21-A0V F006A,B Bypass Valve TER EQUIPMENT ITEM NO: 53 Plant ID: E21-A0V F037B Limit Switches Located in the Containment Namco Model EA180-31302 Service: E21-A0V F006A,B Bypass Valve TER EQUIPMENT ITEM NO: 54 Plant ID: Ell-A0V F122A,B Limit Switches Located in the Containnent Namco Model EA180-31302 Service: Testable Check Bypass TER EQUIPMENT ITEM No: 55 Plant ID: B31-A0V F019 Limit Switches Located in the Containment Namco Model EA180-31302 Service: Reactor _ Water Sample Isolation
(h
(/
TER EQUIPMENT ITEM No: 56 Plant ID: E21-A0V F006A B Limit Switches Located in the Containment Namco Model EA740-20001 Service: Core Spray Pump Discharge Isolation TER EQUIPMENT ITEM No: 57 Plant ID: B21-A0V F022A,B.C.D Limit Switches Located in the Containment Namco Model EA740-50100 Service: Main Steam Line Isolation TER EQUIPMENT ITEM NO: 57 Plant ID: B21-AOV F028A,B.C.D Limit Switches Located in the Pipe Chase Namco Model EA740-50100 Service: Main Steam Line Isolation TER EOUIPr3NT ITEM NO: 58 Plant ID: G51-A0V F011 Limit Switches Located in the Torus Room Namco Model EA180 31302 Service: Torus Water Cleanup Isolation O
G
,-~
TER EQUIPMENT ITEM NO: 58 Plant ID: G51-A0V F012 Limit Switches Located in the Torus Room Namco Model EA180-31302 Service: Torus Water Cleanup Isolation TER EQUIPMENT ITEM NO: 59 Plant ID: P41-A0V F067 Limit Switches Located in the Torus Roon Namco Model EA180-31302 & EA180-32302 Service: Plant Service Water Isolation to Reactor Building TER EQUIPMENT ITEM NO: 59 Plant ID: P41-A0V F066 Limit Switches Located in the Torus Room Namco Model EA180-31302 & EA180-32302 Service: Plant Service Water Isolation to Reactor Building TER EQUIPMENT ITEM NO: 60 Plant ID: T46-A0V F004A,B Limit Switches Located in the Reactor Building, Elev. 164' 0" Namco Model EA180-31302 & EA180-32302 Service: Filter Discharge Isolation f TER EQUIPMENT ITEM NO: 60 Plant ID: T46-A0V F005 Limit Switches Located in the Reactor Building, Elev. 164' 0" Namco Model EA180-31302 & EA180-32302 Service: System Discharge to Main Stack TER EQUIPMENT ITEM NO: 60 Plant ID: T46-A0V F003A,B Limit Switches Located in the Reactor Building, Elev. 164' 0" Namco Model EA180-31302 & EA180-32302 Service: Filter Discharge Isolation TER EQUIPMENT ITEM NO: 60 Plant ID: T46-A0V F002A,B Limit Switches Located in the Reactor Building, Elev. 164' 0" Namco Model EA180-31302 & EA180-32302 Service: Filter Discharge Isolation TER EQUIPMENT ITEM NO: 60 Plant ID: T46-A0V F001A,B Limit Switches Located in the Reactor Building, Elev. 164' 0" Namco Model EA180-31302 & EA180-32302 Service: Filter Suction Isolation
{%
i I
\- / TER EQUIPMENT ITEM NO: 61 Plant ID: T41-A0V F044A,B Limit Switches Located in the Reactor Building, Elev. 164' 0" Namco Model EA180-31302 & EA180-32302 Service: Reactor Building, Exhaust Fan Discharge Isolation TER EQUIPMENT ITEM NO: 61 Plant ID: T41-A0V F032A,B Limit Switches Located in the Reactor Building, Elev. 164' 0" Namco Model EA180-31302 & EA180-32302 Service: Reactor Building, Vent Discharge to Standby Gas Treatment TER EQUIPMENT ITEM NO: 61 Plant ID: T41-A0V F031A,B Limit Switches Located in the Reactor Building, Elev. 164' 0" Namco Model EA180-31302 & EA180-32302 Service: Reactor BuildinF, Exhaust Fan Discharge Isolation TER EQUIPMENT ITEM NO: 61 Plant ID: T41-A0V F023A,B, Limit Switches Located in the Reactor Building, Elev. 164' 0" Namco Model EA180-31302 & EA180-32302 Service: Refueling Floor Exhaust Fan Discharge Isolation f- TER EQUIPMENT ITEM NO: 62
( Plant ID: P33-A0V F002 Limit Switches Located in the Reactor Building. Elev. 185' 0" Namco Model EA180-31302 Service: H and 0 Drywell Isolation 3 2 TER EQUIPMENT ITEM NO: 62 Plant ID: P33-A0V F010 Limit Switches Located in the Reactor Building, Elev. 185' 0" Namco Model EA180-31302 Service: H and 0 Drywell Isolation 2 2 TER EQUIPMENT ITEM NO: 62 Plant ID: P70-A0V F002 Limit Switches Located in the Reactor Building, Elev. 130' 0" Namco Model EA180-31302 Service: Drywell Pneumatic Isolation TER EQUIPMENT ITEM NO: 62 Plant ID: P70-A0V F003 Limit Switches Located in the Reactor Building, Elev. 130' 0" Namco Model EA180-31302 Service: Drywell Pneumatic Isolation O
O 1
j
O b
TER EQUIPMENT ITEM NO: 62 Plant ID: P70-A0V F004 Limit Switches located in the Reactor Building, Elev. 130' 0" Namco Model EA180-31302 Service: Drywell Pneumatic Isolation TER EQUIPMENT ITEM NO: 62 Plant ID: P70-A0V F005 Limit Switches Located in the Reactor Building, Elev. 130' 0" Namco Model EA180-31302 Service: Drywell Pneumatic Isolation TER EQUIPMENT ITEM NO: 62 Plant ID: T48-A0V F104 Limit Switches Located in the Reactor Building, Elev. 130' 0" Namco Model EA180-31302 Service: Drywell/ Torus Nitrogen Makeup Isolation TER EQUIPMENT ITEM NO: 63 Plant ID: G51-A0V F013 Limit Switches Located in the Northeast Corner Room Naeco Model EA180-31302 Service: Torus Water Makeup Isolation D)
( ,
TER EQUIPMENT ITEM NO: 63 Plant ID: G51-A0V F021 Limit Switches Located in the Northeast Corner Room Namco Model EA180-31302 Service: Torus Water Makeup Isolation TER EQUIPMENT ITEM NO: 64 Plant ID: E41-A0V F025 Limit Switches Located in the HPCI Room Namco Model EA180-31302 Service: Condenser Pump Discharge Drain Isolation TER EQUIPMENT ITEM NO: 64 Plant ID: E41-A0V F029 Limit Switches Located in the HPCI Room Namco Model EA180-31302 Service: Steam Pot Drain Isolation TER EQUIPMENT ITEM NO: 64 Plant ID: E41-A0V F028 Limit Switches Located in the HPCI Room Namco Model EA180-31302 Service: Steam Pot Drain Isolation TER EQUIPMENT ITEM N0: 64 Plant ID: E41-A0V F026
\ .
Limit Switches Located in the HPCI Room Namco Model EA180-31302 Service: Condenser Puep Discharge Drain Isolation
\
V TER EQUIPMENT ITEM No: 65 Plant ID: B31-A0V F020 Limit Switches Located in the Reactor Building, Elev. 158' 0" Namco Model EA180-31302 Service: Reactor Water Sample Isolation TER EQUIPMENT ITEM NO: 65 Plant ID: P33-A0V F003 Limit Switches Located in the Reactor Building, Elev. 158' 0" I Namco Model EA180-31302 Service: H and 0 Drywell Isolation 2 2 TER EQUIPMENT ITEM NO: 65 Plant ID: P33-A0V F011 Limit Switches Located in the Reactor Building, Elev. 158' 0" Namco Model EA180-31302 Service: H and 0 Drywell Isolation 2 2 TER EQUIPMENT ITEM NO: 66 Plant ID: G11-A0V F020 Limit Switches located in the Torus Room .
Namco Model EAlu0-31302 Service: Drywell Equipment Drain Sump Discharge Isolation
('-- TER EQUIPMENT ITEM NO: 66 Plant ID: Gil-A0V F019 Limit Switches Located in the Torus Room Namco Model EA180-31302 Service: Drywell Equipment Drain Sump Discharge Isolation TER EQUIPMENT ITEM NO: 66 Plant ID: Gil-A0V F004 Limit Switches Located in the Torus Room Namco Model EA180-31302 Service: Drywell Floor Drain Sump Discharge Isolation i
TER EQUIPMENT ITEM NO: 66 Plant ID: G11-A0V F003 Limit Switches Located in the Torus Room Namco Model EA180-31302 Service: Drywell Floor Drain Sump Discharge Isolation TER EQUIPMENT ITEM NO: 67 Plant ID: T41-A0V F011B Limit Switches Located in the Reactor Building, Elev. 185' 0" Namco Model EA180-31302 & EA180-32302 Service: Reactor Building Supply Fan Discharge Isolation
O TER EQUIPMENT ITEM NO: 67 Plant ID: T48-A0V F319 Limit Switches Located in the Reactor Building, Elev. 185' 0" Namco Model EA180-31302 & EA180-32302 Service: Drywell Discharge Isolation TER EQUIPMENT ITEM NO: 67 Plant ID: T48-A0V F320 Limit Switches Located in the Reactor Buildiag, Elev. 185' 0" Namco Model EA180-31302 & EA180-32302 Service: Drywell Discharge Isolation TER EQUIPMENT ITEM NO: 67 Plant ID: T48-A0V F334A,B Limit Switches Located in the Reactor Building, Elev. 185' 0" Namco Model EA180-24302 & EA180-25302 Se rvice : Drywell Bypass Isolation TER EQUIPMENT ITEM NO: 67 Plant ID: T48-A0V F335A,B Limit Switches Located in the Reactor Building, Elev. 185' 0" Namco Model EA180-24302 & EA180-25302 Se rvice : Drywell Bypass Isolation e TER EQUIEMENT ITEM NO: 68 Plant ID: T48-A0V F311 Limit Switches Located in the Torus Room Namco Model EA180-31302 & EA180-32302 Service: Torus Pressure Equalization Isolation TER EQUIPMENT ITEM NO: 68 Plant ID: E11-A0V F065A,B.C.D Limit Switches located in the Torus Roon Namco Model EA180-31302 & EA180-32302 Service: RER Pump Suction Isolation TER EQUIPMENT ITEM NO: 68 Plant ID: E41-A0V F051 Limit Switches Located in the Torus Room Namco Model EA180-313C2 & EA180-32302 Service: Torus Discharge Isolation to HPCI Pump TER EQUIPMENT ITEM NO: 68 Plant ID: E51-A0V F003 Limit Switches Located in the Torus Room Namco Model EA180-31302 & EA180-32302 Service: Torus Discharge Isolation to RCIC Pump 9
[\
\~~/
TER EQUIPMENT ITEM NO: 68 Plant ID: E21-A0V F019A,B Limit Switches Located in the Torus Room Namco Model EA180-31302 & EA180-32302 Service: Torus to Core Spray Pump Suction Isolation TER E0UIPMENT ITEM NO: 68 Plant ID: T48-AOV F103 Limit Switches Located in the Torus Room Namco Model EA180-31302 & EA180-32302 Service: Drywell/ Torus Purge Isolation TER EQUIPMENT ITEM NO: 68 Plant ID: T48-A0V F307 Limit Switches Located in the Torus Roon Namco Model EA180-31302 & EA180-32302 Service: Purge Isolation to Drywell TER EQUIPMENT ITEM NO: 68 Plant ID: T48-A0V F308 Limit Switches Located in the Torus Room Namco Model EA180-31302 & EA180-32302 Service: Purge Isolation to Drywell
) TER EQUIPMENT ITEM NO: 68
\~ / Plant ID: T48-A0V F309 Limit Switches Located in the Torus Room Namco Model EA180-31302 & EA180-32302 Service: Purge Isolation to Torus TER EQUIPMENT ITEM NO: 68
- Plant ID
- T48-A0V F310 Limit Switches Located in the Torus Room Namco Model EA180-31302 & EA180-32302 Service: Torus Pressure Equal Isolation TER EQUIPMENT ITEM NO: 68 Plant ID: T48-A0V F318 Limit Swite'.ies Located in the Torus Room Namco Model EA180-31302 & EA180-32302 Service: Torus Discharge Isolation TER EQUIPMENT ITEM NO: 68 Plant ID: T48-A0V F324 Limit Switches Located in the Torus Room Namco Model EA180-31302 & EA180-32302 Service: Purge Isolation to Torus O
TER EQUIPMENT ITEM NO: 68 Plant ID: T48-A0V F326 Limit Switches Located in the Torus Room Namco Model EA180-31302 & EA180-32302 Service: Torus Discharge Isolation TER EQUIPMENT ITEM NO: 68 Plant ID: T48-A0V F332A,B Limit Switches Located in the Torus Room Namco Model EA180-24302 & EA180-25302 Service: Torus Bypass Isolation TER EQUIPMENT ITEM NO: 68 Plant ID: T48-A0V F333A,B Limit Switches Located in the Torus Room Names Model EA180-24302 & EA180-25302 Service: Torus Bypass Isolation
- iR EQUIPMENT ITEM NO: 69 tant ID: P33-A0V F007 Limit Switches Located in the Torus Room Namco Model EA180-31302 Service: H and 0 Torus Isolation 2 2
, TER EQUIPMENT ITEM NO: 69 Plant ID: P33-A0V F012
, Limit Switches Located in the Torus Room Namco Model EA180-31302 Service: H and 0 Return to Drywell Isolation 2 2 TER EQUIPMENT ITEM N0: 69 Plant ID: P33-A0V F014 Limit Switches Located in the Torus Room Namco Model EA180-31302 Service: H and 0 Drywell Isolation 2 2 TER EQUIPMENT ITEM NO: 69 Plant ID: P33-A0V F004 Limit Switches Located in the Torus Room Namco Model EA180-31302 Service: H and O Return to Drywell Isolation 2 2 TER EQUIPMENT ITEM NO: 69 Plant ID: P33-A0V F006 Limit Switches Located in the Torus Room Namco Model EA180-31302 Service: H and 0 Drywell Isolation 2 2 O
--,,-..r, - . - - . - - - , , , , - . , , - - - - - - , - - - - - - - - ~ - - . - -, - - - , , , - - - - . , - - - - - - - - , - - . - - - - - - - - - - ~ - - - - , - - , - - - . -
l O TER EQUIPMENT ITEM NO: 69 Plant ID: P33-A0V F015 Limit Switches Located in the Torus Room Namco Model EA180-31302 Service: H2 and 0 7Torus Iso 1'ation TER EQUIPMENT ITEM NO: 69 Plant ID: T48-A0V F113 Limit Switches Located in the Torus Room Namco Model EA180-31302 Service: Drywell Nitrogen Makeup Isolation TER EQUIPMENT ITEM NO: 69 Plant ID: T48-A0V F114 Limit Switches Located in the Torus Room Namco Model EA180-31302 Service: Drywell Nitrogen Makeup Isolatica TER EQUIPMENT ITEM NO: 69 Plant ID: T48-A0V F115 Limit Switches Located in the Torus Room Namco Model EA180-31302 Service: Torus Nitrogen Makeup Isolation nN. -
TER EQUIPMENT ITEM NO: 69 Plant ID: T48-A0V F116 Limit Switches Located in the Torus Room Namco Model EA180-31302 Se rvice: Torus Nitrogen Makeup Isolation TER EOUIPMENT ITEM No: 69 Plant ID: T48-A0V F321 Limit Switches Located in the Torus Room Namco Model EA180-31302 Service: Drywell Nitrogen Makeup Isolation TER EQUIPMENT ITEM NO: 69 Plant ID: T48-A0V F322 Limit Switches Located in the Torus Room Namco Model EA180-31302 Service: Drywell Nitrogen Makeup Isolation TER EQUIPMENT ITEM NO: 69 Plant ID: T48-A0V F325 I
Limit Switches Located in the Torus Room Namco Model EA180-31302 Service: Torus Nitrogen Makeup Isolation
~~-)
O TER EQUIPMENT ITEM NO: 69 Plant ID: T48-A0V F327 Limit Swi~tches Located in the Torus Room Namco Model EA180-31302 Service: Torus Nitrogen Makeup Isolation TER EQUIPMENT ITEM NO: 87 Plant ID: Ell-PS N017A,B C.D Pressure Switches Located in the Northeast and Southeast Corner Rooms Static-0-Ring Model 7924100 Service: RHR Service Water Valve F068A&B Permissive TER EQUIPMENT ITEM NO: 88,89 Plant ID: B21-PS N301A,B C.D E.F,G.H,J.K,L Pressure Switches Located in the Containment Pressure Controls Inc. Model A17-1P Service: SRV Monitoring TER EQUIPMENT ITEM NOS: 91,93 Plant ID: Terminal Tape Electrical Tape Located Inside the Drywell Okonite Model T95 Service: Insulation of Termination & Splices TER EQUIPMENT ITEM NOS: 92,90 Plant ID: Jacketing Tape Electrical Tape Located Inside the Drywell Okonite Model T35 Service: Protection of Termination & Splices TER EQUIPMENT ITEM NO: 95 Plant ID: C82 Control Switch Control Switch Located in the Reactor Building, Elev. 158' 0" Electro Switch Model Series 20 Service: Control Switch TER EQUIPMENT ITEM NO: 96 Plant ID: C82 Transfer Switch Control Switch Located in the Reactor Building, Elev. 158' 0" Electro Switch Model Series 40 Service: Transfer Switch 6
I TER EQUIPMENT ITEM NO: 100 Plant ID: Rll-S040 Transformer Located in the Reactor Building, Elev. 130' 0" Sorgel Model Serial No. 101023-5 Service: MCC R24-S012 TER EQUIPMENT ITEM NO: 100 Plant ID: R11-S039 Transformer Located in the Reactor Building, Elev. 130' 0" Sorgel Model Serial No. 101023-5 Service: MCC R24-S011 TER EQUIPMENT ITEM NO: 102 Plant ID: PWB Heat Shrink Electrical Cable Splice Located Outside the Drywell Raychem Model HVTIA20C Service: #2/0 and #3/0 Aug Wire, 8KV TER EQUIPMENT ITEM NOS: 103,104 Plant ID: PVT Heat Shrink Electrical Cable Splice Located Inside/Outside the Drywell Raychem Model WCSF0706N Service: #18 to #10 Awg Wire, 600 Volt TER EQUIPMENT ITEM NOS: 103,104 (m,/ Plant ID: PWH Heat Shrink Electrical Cable Splice Located Inside/Outside the Drywell Raychem Model WCSF0706N Service: #9 Avg Wire, 600 Volt TER EQUIPMENT ITEM NO: 104 Plant ID: PWK Heat Shrink Electrical Cable Splice Located Outside the Drywell Raychem Model WCSF0706N Service: 600 V TER EQUIPMENT ITEM NO: 104 Plant ID: PWJ Heat Shrink Electrical Cable Splice Located Outside the Drywell Raychem Model WCSF0706N i Service: #2, #1, #1/0 #2/0 Avg Wire, 600 V C
O TER EQUIPMENT ITEM NO: 104 Plant ID: PWI Heat Shrink Electrical Cable Splice Located Outside the Drywell Raychem Model WCSF0706N Service: #6 & #4 Awg Wire, 600 V TER EQUIPMENT ITEM NO: 105,106 Plant ID: D11-RE N003A,B Radiation Monitor Located in the Containment Victoreen Model 877-1 Service: Containment High Range Radiation Monitoring TER EQUIPMENT ITEM NO: 111,181 Plant ID: T48-LT N021A,B Level Transmitter Located in the Torus Room Rosemount Model 1153DB3 Service: Torus Water Level Narrow Range TER EQUIPMENT ITEM NO: 111;113 Plant ID: T48-LT N010A,B Level Transmitter Located in the Torus Room Rosemount Model 1153DB5 Service: Torus Water Level Wide Range TER EQUIPMENT ITEM NO: 117 Plant ID: T48-PT N003A,B Pressure Transmitter Located in the Reactor Building, Elev. 158' 0" Rosemount Model 1153GB7 Service: Containment Pressure Wide Range TER EQUIPMENT ITEM NO: 116,117 Plant ID: T48-PT N023A,B Pressure Transmitter Located in the Reactor Building, Elev. 158' 0" Rosemount Model 1153GB6 Service: Containment Pressure Mid-Range TER EQUIPMENT ITEM No: 113,117 Plant ID: T48-PT N020A,B Pressure Transnitter Located in the Reactor Building, Elev. 158' 0" Rosemount Model 1153GB5 Service: Containment Pressure Narrow Range k
U TER EQUIPMENT ITEM NO: 130 Plant ID: T52 Electrical Penetration located in Elev. 130' 0" General Electric Model F01 Service: Cable Penetration Inside/Outside Drywell TER EQUIPMENT ITEM NO: 132 Plant ID: RPT Switchgear Switchgear Located in the Reactor Building, Elev. 185' 0" Westinghouse Model 50DHP250 Service: Recirculation Pump Trip TER EQUIPMENT ITEM No: 133 Plant ID: R27-S005 Motor Starter Located in the Reactor Building, Elev. 130' 0" Allis Chalmers Model Valueline Mark I Service: Electrical Mctor Power TER EQUIPMENT ITEM NO: 134 Plant ID: R27-S035 Motor Starter Located in the Reactor Building, Elev. 130' 0" General Electric Model 378X938N01 Service: Electrical Power Distribution TER EQUIPMENT ITEM No: 135 l'sd) Plant ID: R27-S037 Motor Starter Located in the HPCI Room General Electric Model 378X938N01 Service: Motor Power TER EQUIPMENT ITEM NO: 135 Plant ID: R27-S036 Motor Starter Located in the HPCI Room General Electric Model 378X938N01 Service: Motor Power TER EQUIPMENT ITEM NO: 136 Plant ID: R27-S022 Motor Control Center Located in the Reactor Building, Elev. 130' 0" Cutler Hammer Model Unitrol Service: Electrical Power Distribution TER EQUIPMENT ITEM NO: 136 Plant ID: R24-S021A Motor Control Center Located in the Reactor Building, Elev. 130' 0" Cutler Hammer Model Unitrol Service: Electrical Power Distribution O
i TER EQUIPMENT ITEM NO: 137 Plant ID: R27-S006 Motor Starter Located in the Reactor Building, Elev. 130' 0" Allis Chalmers Model Valueline Mark I Service: Electrical Motor Power TER EQUIPMENT ITEM NO: 137 Plant ID: R24-S011 Motor Starter Located in the Reactor Building, Elev. 130' 0" Allis Chalmers Model Valueline Mark I Service: Electrical Power Distribution TER EQUIPMENT ITEM NO: 137 Plant ID: R24-S012 Motor Starter Located in the Reactor Building, Elev. 130' 0" Allis Chalmers Model Valueline Mark I Service: Electrical Power Distribution i
TER EQUIPMENT ITEM NO: 137 Plant ID: R24-S013 Motor Starter Located in the Reactor Building, Elev. 130' 0" Allis Chalmers Model Valueline Mark I Service: Electrical Power Distribution
/O TER EQUIPMENT ITEM NO: 137 U Plant ID: R24-S018A,B Motor Starters Located in the Reactor Building, Elev. 130' 0" Allis Chalmers Model Valueline Mark I Service: Electrical Power Distribution TER EQUIPMENT ITEM NO: 138 Plant ID: E21-C001A.B Electrical Motor located in the Northeast and Southeast Corner Rooms General Electric Model 5K6339XC92A Service: Core Spray System 1
TER EQUIPMENT ITEM NO: 139 Plant ID: E11-C002A,B,C D Electrical Motor Located in the Northeast and Southeast Corner Rooms General Electric Model SK6339XC89A Service: RHR System TER EQUIPMENT ITEM NO: 140 Plant ID: T46-C001A,B Electric Motor Located in the Reactor Building, Elev. 164' 0" Joy Manufacturing Model 18-14-3450
, Service:-Standby Gas Treatment System o
,-.-4 , __ - . -
9 TER EQUIPMENT ITEM NO: 141 Plant ID: T41-B003A B Electric Motor Located in the Northeast Corner Room Joy Manufacturing Series 1000 Axivance Fan Model 29k - 17h - 1750 Service: RHR/ Core Spray Pump Room Cooler TER EQUIPMENT ITEM NO: 141 Plant ID: T41-B004A,B Electric Motor Located in the RCIC (SW) Corner Room Joy Manufacturing Series 1000 Axivance Fan Model 29k 1750 Service: RCIC Pump Room Cooler TER EQUIPMENT ITEM NO: 141 Plant ID: T41-B005A,B Electric Motor Located in the HPCI Room Joy Manufacturing Series 1000 Axivance Fan Model 29k 1750 Service: HPCI Pump Room Cooler TER EQUIPMENT ITEM NO: 141 Plant ID: T41-B002A,B Electric Motor Located in the Southeast Corner Room Joy Manufacturing Series 1000 Axivance Fan Model 29k 1750
[s/ l Service: RHR/ Core Spray Pump Room Cooler TER EQUIPMENT ITEM No: 143 Plant ID: #14 SIS Vulkene Electric Cable Located Outside The Drywell General Electric Model SI5727511
. Service: General Electric Panel Wiring TER EQUIPMENT ITEM NO: 146 Plant ID: K1-01 Electrical Cable, Thermocouple Located Outside the Drywell Boston Insulated Wire 2/C - #16 Awg Service: Thermocouple Cable i
TER EQUIPMENT ITEM NO: 147 Plant ID: M27-16T Electrical Cable, Control Located Outside the Drywell Boston Insulated Wire Model 600V Service: Control Cable TER EQUIPMENT ITEM NO: 149 Plant ID: #14 SI5 Anaconda Electrical Cable, Control Located in the Reactor Building, Elev. 158' 0" Continental Wire Model # 39121090114XPSIS Service: Remote Shutdown Panel f,) .
L
A TER EQUIPMENT ITEM NO: 150 Plant ID: C17 Electrical Cable, Control Located Outside the Drywell Okonite Model 600 V Service: Control TER EQUIPMENT ITEM No: 150 Plant ID: C4-16T Electrical Cable, Control Located Outside the Drywell Okonite Model 600 V Service: Control TER EQUIPMENT ITEM NO: 150,152 Plant ID: C4-14T Electrical Cable, Control Located Inside/Outside the Drywell Okonite Model 4/C-14 Ak'G, 600V Service: Control TER EQUIPMENT ITEM NO: 152 Plant ID: C2-9T Electrical Cable, Control Located in the Torus Room Okonite Model 600 V Service: This Sheet Applies to Valve E11-A0V F065A,B C.D Only TER EQUIPMENT ITEM NO: 153,150,151
}
s_ ,e Plant ID: C7-14T Electrical Cable, Control Located Inside/Outside the Drywell Okonite Model 600 V Service: Control TER EQUIPMENT ITEM NO: 153,152 Plant ID: C9-14T Electrical Cable, Control Located Outside the Drywell Okonite Model 600 V Service: Control TER EQUIPMENT ITEM NO: 153 Plant ID: C7-12T Electrical Cable. Control Located Outside the Drywell l Okonite Model 600 V Service: Control TER EQUIPMENT ITEM NO: 153 Plant ID: C4-12T Electrical Cable, Control Located Outside the Drywell Okonite Model 600 V Service: Control i
TER EQUIPMENT ITEM No: 153 Plant ID: C2-12T
,[)v Electrical Cable, Control Located Outside the Drywell Okonite Model 600 V Service: Control
-y. - pp. + ,-.m-. - . - .y-..,-- - , , . ., - -- ., -.-t= ~w~-w Tm - g-c-4 -- -= g- pi.e-- --W-W-e--- --- + *-g
l O TER EQUIPMENT ITEM NO: 153 Plant ID: C4-9T Electrical Cable, Control Located Outside the Drywell Okonite Model 600 V Service: Power TER EQUIPMENT ITEM NO: 153 Plant ID: C7-9T Electrical Cable, Control Located Outside the Drywell Okonite Model 600 V Service: Power TER EQUIPMENT ITEM NO: 153 Plant ID: C4-6T Electrical Cable, Control Located Outside the Drywell Okonite Model 600 V Service: Power TER EQUIPMENT ITEM NO: 153 Plant ID: C1-02 Electrical Cable, Control Located Inside the Drywell Okonite Model 600 V Service: Power TER EQUIPMENT ITEM NO: 156 s ,_ Plant ID: N2-7 Electrical Cable Instrument Located Inside the Drywell Okonite Model 600 V PVC Service: Control TER EQUIPMENT ITEM No: 156,150 Plant ID: N2-5 2
Electrical Cable, Instrument Located Inside/Outside the Drywell Okonite Model 600 V PVC Service: Control TER EQUIPMENT ITEM NO: 156,150 Plant ID: C2-14T
- Electrical Cable, Instrument Located Inside/Outside the Drywell Okonite Model 600 V PVC Service: Control TER EQUIPMENT ITEM NO: 157,158 Plant ID: H04 Electrical Cable, Instrument Located Inside/Outside the Drywell Anaconda Wire and Cable Model 600 V Service: Instrumentation U
1
,- --. . -- - - . - - - - - - - . - - - - . . , , , - - - . , , . . , , , - - - , - - . , . - , - ,-,,-,,.---..n.--. .--, - - - - - - . -. - - - - -~.,---
i TER EQUIPMENT ITEM NO: 160 Plant ID: B22 Electrical Cable, Power Located Outside the Drywell Okonite Model 2000V Service: Power TER EQUIPMENT ITEM NO: 161 Plant ID: Al-03S Electrical Cable, Power Located Outside the Drywell Okonite Model 5000V Service: Power TER EOUIPMENT ITEM NO: 161 Plant ID: Al-250S Electrical Cable, Power Located Outside the Drywell Okonite Model 5000V Service: Power TER EQUIPMENT ITEM NO: 162' Plant ID: B3-350A Electrical Cable, Power Located Outside the Drywell Okonite Model 1000V Service: Power
) TER EQUIPMENT ITEM NO: 162 Plant ID: Dl-6 Electrical Cable, Power Located Outside the Drywell Okonite Model 1000V f Service: Power TER EQUIPMENT ITEM NO: 162 Plant ID: Dl-04 Electrical Cable, Power Located Outside the Drywell Okonite Model 1000V Service: Power TER EQUIPMENT ITEM NO: 162 Plant ID: Dl-02 Electrical Cable, Power Located Outside the Drywell l Okonite Model 1000V Service: Power TER EQUIPMENT ITEM NO: 162 l Plant ID: D3-500A Electrical Cable Power Lccated Outside the Drywell Okonite Model 1000V Service: Power l
l O
l I
L l - . - - , - -
TER EQUIPMENT ITEM NO: 162 Plant ID: B1-6 Electrical Cable, Power Located Outside the Drywell Okonite Model 1000V Service: Power TER EQUIPMENT ITEM NO: 162 Plant ID: B3-6A Electrical Cable, Power Located Outside the Drywell Okonite Model 1000V Service: Power TER EQUIPMENT ITEM NO: 162 Plant ID: B3-250A Electrical Cable, Power Located Outside the Drywell Okonite Model 1000V Service: Power TER EQUIPMENT ITEM NO: 162 Plant ID: B1-250 Electrical Cable, Power Located Outside the Drywell Okonite Model 1000V Service: Power f\' TER EQUIPMENT ITEM NO: 162 Plant ID: B3-2A Electrical Cable Power Located Outside the Drywell Okonite Model 1000V Service: Power TER EQUIPMENT ITEM NO: 163,162 Plant ID: N2-09 Electrical Cable, Power Located Outside the Drywell Okonite Model 1000V Service: Power TER EQUIPMENT ITEM No: 163,162 Plant ID: B3-9A Electrical Cable, Power Located Inside/Outside the Drywell Okonite Model 1000V Service: Power TER EQUIPMENT ITEM NO: 175,131 Plant ID: States Type NT
, Terminal Block Located Inside the Drywell States Model ZWM Service: Terminal Block O
= ,
TER EQUIPMENT ITEM NO: 176 Plant ID: D11-RE N003A,B (Cable)
Electrical Cable Located in the Containment Victoreen Model 87815 Service: Containment High Range Radiation Monitors TER EQUIPMENT ITEM NO: 177 Plant ID: T48-A0V F310 Solenoid Valve Located in the Torus Room
- ' ASCO Model NP8316A74E Service: Torus Pressure Equal Isolation TER EQUIPMENT ITEM NO: 177 Plant ID: T48-A0V F311 Solenoid Valve Located in the Torus Room ASCO Model NP8316A74E Service: Torus Pressure Equal Isolation TER EOUIPMENT ITEM NO: 179 Plant ID: P42-MOV F052 Motorized Valve Actuator Located in the Torus Room Limitorque Model SMB, AC Service, Class H Insulation Service: RBCCW Isolation from Primary Containment TER EQUIPMENT ITEM NO: 179 O)
(m- Plant ID: P42-MOV F051 Motorized Valve Actuator Located in the Torus Room Limitorque Model SMB, AC Service, Class H Insulation Service: RBCCW Isolation to Primary Containment TER EQUIPMENT ITEM NO: 180 Plant ID: Ell-MOV F104A,B Motorized Valve Actuator Located in the Northeast and Southeast Corner Rooms Limitorque Model SMB, AC Service, Class H Insulation Service: Residual Heat Removal Hx Ventilation Isolation i
V 4
i
1
( ';
Q) The following equipeent was not addressed in Franklin Research Center's 1
Technical Evaluation Report. f However, the equipment-is part of Georgia Power Company's I.E. Bulletin 79-01B Qualified Equipment List.
. ~
T48-A0V F103 Solenoid Valve Located in the Torus Room ,
ASCO Model NP206-380-3F '
Service: Drywell/ Torus Purge Isolation E41-A0V F025 Solenoid Valve Located in the HPCI Room ASCO Model NP206-381-3F /
Service: Condensate Pump Discharge Drain Isolation ,
E41-MOV F008 Motorized Valve Actuator Located in the HPCI Room '
Limitorque Model SMB, DC Service, Class B Insulation /
Service: Test Bypass Isolation to Condensate Storage frank Ell-MOV F010 Motorized Valve Actuator Located in the Torus Room Limitorque Model SMB, AC Service, Class B Insulation Service: RHR Cross Tie
("}
C12-14T s_- Control Cable Located Outside the Drywell '
Okonite Model 12/C #14 Awg 600 V Insulation Service: Control it
' \
T48-A0V F333B '
Solenoid Valve Located in the Torus Room "' '
ASCO Model N?206-380-6RF ,
t Service: Torus Bypass Operation ,
'e f ,
t e
w _r
i
/,..'
(
~
l
! /
1 t
7 . . , . . , - ~ , . , . , , .- ,
.+ , _ . , . . .. , , , . , . , . . . - , n - - -
\
k) -
The following equipment is part of new design changes and not presently installed. However, when installed this equipment will be added to the I. E.
Bulletin 79-01B Equipment List and will be qualified.
Plant ID: P70-PS N006A,B xPressure Switch Located in the Northwest Corner Room ITT Barton Model 580A-2 Service: Air Receiver P70-A001
- Plant ID: P70-FT N020A,B Flow Transmitter Located in Reactor Building
,o Rosemount Model;1153-DB3PA i
Service: Drywell Pneumatic System High Flow Isol.
f Plant ID: P70-FT N022A,B Flow Transmitter Located in Reactor Building
~
Rosemount Model 1153-DB3PA Service: Drywell Pneumatic Systen High Flow Isol.
/ /
I P1' ant ID: Cll-SV-F040 Solenoid Valve Located in the Reactor Building, Elev. 130' 0" ASCO Model NP8323A22E Service: Scram Discharge Valve Isol.
(
\~,/
} Plant ID: T41-A0V-F040A,B Solenoid Valve Located in the Reactor Building, Elev. 164' 0" ASCO Model NP8321A2E '
Service: Out to Stand By Cas Treatment System i
Plant ID: T41-A0V-F040A,B 5 Limit SwitcFe's bocated (in ;the Resctor Building, Elev. 164' 0" NAMCOModelEA180-31302\andEA180-32302 i Service: Out to'6tand By Gas Treatment System 4 oe r Plant ID: P70-SV-7005:
Solenoid Valves L/catel . Reactor Building
~
./ '
Target Rock Model-1121010 Service: Drywell Pneumatic System High Flow Isolation I
Plant ID: P70-SV-F066 Solenoid Valves Located Reactor Building Target Rock Model 1121010 Service: Drywell Pneumatic System High Flow Isolation Plant ID: P70-SV-F067 Solenoid Valves Located Reactor Building Target Rock Model 1121010 Service: Drywell Pneumatic System High Flow Isolation
- -~g Plant ID
- P70-SV-F004 4(lly ') Solenoid Valves Located Reactor Building Target Rock Model 1121010 (g g Service: Drywell Pneumatic System High Flow Isolation 4 I 5
? , ~ - .
O Plant ID: P70-SV-F001B Solenoid Valve Located in the Northwest Corner Room Valcor Model V526-5920-5 Service: Backup Nitrogen Supply Line l
l
}
)
1
)
O' r
O
SECTION C EQUIPMENT REQUIRING QUALIFICATION CLARIFICATIONS INTRODUCTION Thissectionprovidestheinformationandtheclar}ficationsrequiredtoaddress the discrepancies identified by the Nuclear Regulatory Commission (NRC) in the Environmental Qualification Safety Evaluation Report (SER).
Equipment identified by the NRC as requiring information and/or clarifications are those in NRC Qualification Categories I.b. - Ec.aipment Qualification Pending Modification, II.a. - Equipment Qualification Not Established, II.b - Equipment Not Qualified and II.c - Equipment satisfies all requirements except qualified life or replacement schedule justified. The NRC has not classified any Plant Hatch Unit 1 equipment as Qualification Category II.b Georgia Power Company's thirty (30) day response t the NRC Safety Evaluation Report, Revision 0, dated May 6, 1983 addresses the NRC Di,crepancy(s) for equipment in Qualification Categories I.b an II.a. Therefore, this section only addresses equipment in Qualification Category II.c.
The plant identification numbers, locations, manufacturers, model numbers, and plant services are listed for each individual TER equipment item number, followed by the discrepancy (s) noted in the Technical Evaluation Report (TER).
The NRC discrepancy (s) is (are) addressed in the clarification section.
O t
(
V TER EOUIPMENT ITEM NO. 1 Motorized Valve Actuator Located in the Peactor Building, Elev. 130'0" Plarc ID: T48-MOV F013A,B Limitorque Model SMB, Class H Insulation Service: Nitrogen Makeup Isolation NRC DISCREPANCY Aging Degradation Evaluated Adequately Qualified Life or Replacement Schedule Established A. The licensee has not provided documented evidence from the manufacturer that the installed equipment and the test specimen (s) in the referenced report (s) are similar. The licensee has also not identified any motori ed valve actuators that incorporate motor-brake assemblies, yet has referenced reports which tested motorized valve actuators with such devices. The licensee should obtain the information necessary to establish similarity, or submit the same if it is already in their central file (also referencing this information on the System Component Evaluation Worksheets (SCEWs)).
B. The licensee has cited B0058 in an effort to establish similarity between the installed equipment and that which has been tested by Limitorque. It
['} should be noted that Limitorque's generic qualification is acceptable, but
\s,/ that this report does not in itself establish similarity, nor does it establish a conservative qualified life for the equipment. In order to establish a qualified life estimate for this equipment, the licensee must completely identify the installed components (i.e. motor lead insulation.)
and then calculate a qualified life based on available information. This available information can come from either testing performed prior to environmental testing or from published data. None of the referenced reports have calculated a qualified life based on an acceptable technique. It should also be noted that the thermal aging that has been performed has been done on individual components or simulates only a fraction of the qualified life claimed. No basis has been stated in the report for the times or temperatures chosen for the thermal aging performed.
CLARIFICATION Documented evidence establishing similarity between the installed equipment and the test specimen is provided by the manufacturer and can be found in Georgia Power Company's Qualification Documentation Files.
O
\~
\
- _ . _ _ - _ - _ _ _ - _ . _ _ _ _ _ _ _ _ _ _. - . - . _ . . - _ . _ __ U
O TER EOUIPMENT ITEM NO. 1 (Continued)
Additionally, FRC states that a qualified life has not been established in an acceptable manner. The D0R Guidelines do not require a qualified life to be established for all equipment.
Georgia Power Company has performed further evaluation of age sensitive components and, using available test data and published data, established a qualified life in accordance with the requirements of the DOR Guidelines.
Therefore, this equipment is considered qualified and Justification for Continued Operation is not required.
O o
G
4 V)
[
TER EOUIPMENT ITEM NO. 4 Motorized Valve Actuator Located in the Pipe Penetration Room Plant ID: Ell-MOV F015A Limitorque Model SB3, AC Service, Class H Insulation Service: LPCI Discharge Isolation NRC DISCREPANCY Aging Degradation Evaluated Adequately Qualified Life or Replacement Schedule Established A. The licensee has not provided documented evidence from the manufacturer that the installed equipment and the test specimen (s) in the referenced report (s) are similar. The licensee has also not identified any motorized valve actuators that incorporate motor-brake assemblies, yet has referenced reports which tested motorized valve actuators with such devices. The licensee should obtain'the information necessary to establish similarity, or submit the same if it is already in their central file (also referencing this information on the System Component Evaluation Worksheets (SCEUs)).
B. The licensee has cited B0058 in an effort to establish similarity between
, the installed equipment and that which has been tested by Limitorque. It should be noted that Linitorque's generic qualification is acceptable, but l [\-)/
that this report does not in itself establish similarity, nor does it establish a conservative qualified life for the equipment. In order to establish a qualified life estimate for this equipment, the licensee must completely identify the installed components (i.e. motor lead insulation.)
and then calculate a qualified life based on available information. This available information can come from either testing performed prior to environmental testing or from published data. None of the referenced reports have calculated a qualified life based on an acceptable technique. It should also be noted that the thermal aging that has been performed has been done on
- individual components or simulates only a fraction of the qualified life claimed. No basis has been stated in the report for the times or temperatures
- chosen for the thermal aging performed.
l l CLARIFICATION l
Documented evidence establishing similarity between the installed equipment and the test specimen is provided by the manufacturer and can be found in Georgia Power Company's Qualification Documentation Files.
O TER EOUIPMENT ITEM NO. 4 (Continued)
Additionally, FRC states that a qualified life has not been established in an acceptable manner. The D0R Guidelines do not require a qualified life to be established for all equipment.
Georgia Power Company has performed further evaluation of age sensitive components and, using available test data and published data, established a qualified life in accordance with the requirements of the DOR Guidelines.
Therefore, this equipment is considered qualified and Justification for Continued Operation is not required.
O O
hiu si i u u aui . . .
p Q TER EQUIPMENT ITEM NO. 7 l
i Motorized Valve Actuator Located in the Reactor Building, Elev. 185'0" l Plant ID: Ell-MOV F023 Limitorque Model SMB, DC Service, Class B Insulation Service: Vessel Head Spray Header Isolation NRC DISCREPANCY Aging Degradation Evaluated Adequately Qualified Life or Replacement Schedule Established A. The licensee has not provided documented evidence from the manufacturer that the installed equipment and the test specimen (s) in the referenced report (s) are similar. The licensee has also not identified any motorized valve actuators that incorporate motor-brake assemblies, yet has referenced reports which tested motorized valve actuators with such devices. The licensee should obtain the information necessary to establish similarity, or submit the same if it is already in their central file (also referencing this information on the System Component Evaluation k'orksheets (SCEk's)).
B. The licensee has cited E0058 in an effort to establish similarity between the installed equipment and that which has been tested by Limitorque. It should be noted that Limitorque's generic qualification is acceptable, but
[mV} that this report does not in itself establish similarity, nor does it establish a conservative qualified life for the equipment. In order to establish a qualified life estimate for this equipment, the licensee must completely identify the installed components (i.e. motor lead insulation.)
and then calculate a qualified life based on available information. This available information can come from either testing performed prior to environmental testing or from published data. None of the referenced reports have calculated a qualified life based on an acceptable technique. It should also be noted that the thermal aging that has been performed has been done on l individual components or simulates only a fraction of the qualified life claimed. No basis has been stated in the report for the times or temperatures i chosen for the thermal aging performed.
However, it is noted that the accident environment is relatively "non-harsh" and that any combination of components which could be found in Limitorque motorized valve actuators should be able to withstand these conditions. due to this fact, the only deficiency that exists is that of qualified life.
CLARIFICATION Documented evidence establishing similarity between the installed equipment and the test specimen is provided by the manufacturer and can be found in Georgia Power Company's Qualification Documentation Files.
v
O TER EOUIPMENT ITEM NO. 7 (Continued)
Additionally, FRC states that a qualified life has not been established in an acceptable manner. The DOR Guidelines do not require a qualified life to be established for all equipment.
Georgia Power Company has performed further evaluation of age sensitive components and, using available test data and published data, established a qualified life in accordance with the requirements of the DOR Guidelines.
Therefore, this equipment is considered qualified and Justification for Continued Operation is not required.
O I
- O
~ - _ _ _ . - - _ , , . , _ _ . _ _ - - - . . _ . _ _ _ _ ,-
O TER EOUIPMENT ITEM NO. 11 Motorized Valve Actuator Located in the Northeast and Southeast Corner Rooms Plant ID: E21-MOV F001A,B Limitorque Model SMB, AC Service, Class B Insulation Service: Core Spray Pump Suction Isolation NRC DISCREPANCY Aging Degradation Evaluated Adequately Qualified Life or Replacement Schedule Established A. The licensee has not provided documented evidence from the manufacturer that the installed equipment and the test specimen (s) in the referenced report (s) are similar. The licensee has also not identified any motorized valve actuators that incorporate motor-brake assemblies, yet has referenced reports which tested motorized valve actuators with such devices. The licensee should obtain the information necessary to establish similarity, or submit the same if it is already in their central file (also referencing this information on the System Component Evaluation Worksheets (SCEWs)).
B. The licensee has cited B0058 in an effort to establish similarity between the installed equipment and that which has been tested by Limitorque. It
/ should be noted that Limitorque's generic qualification is acceptable, but
(. that this report does not in itself establish similarity, nor does it establish a conservative qualified life for the equipment. In order to establish a qualified life estimate for this equipment, the licensee must completely identify the installed components (i.e. motor lead insulation.)
and then calculate a qualified life based on available information. This available information can come from either testing performed prior to environmental testing or from published data. None of the referenced reports have calculated a qualified life based on an acceptable technique. It should also be noted that the thermal aging that has been performed has been done on individual components or simulates only a fraction of the qualified life claimed. No basis has been stated in the report for the times or temperatures chosen for the thermal aging performed.
However, it is noted that the accident environment is relatively "non-harsh" and that any combination of components which could be found in Limitorque motorized valve actuators should be able to withstand these conditions. Due to this fact, the only deficiency that exists is that of qualified life.
CLARIFICATION Documented evidence establishing similarity between the installed equipment and the test specimen is provided by the manufacturer and can be found in Georgia Power Company's Qualification Documentation Files.
O
~-
_-o._ ... ._ . . . . . .
f
(
TER EQUIPMENT ITEM NO. 11 (Continued) ,
l Additionally, FRC states that a qualified life has not been established in an acceptable manner. The DOR Guidelines do not require a qualified life to be established for all equipment.
Georgia Power Company has performed further evaluation of age sensitive
, components and, using available test data and published data, established a qualified life in accordance with the requirements of the DOR Guidelines.
Therefore, this equipment is considered qualified and Justification for Continued Operation is not required.
O i
i t
TER EQUIPMENT ITEM NO. 17 Motorized Valve Actuator Located in the HPCI Room Plant ID: E41-MOV F004 Limitorque Model SMB, DC Service, Class B Insulation Service: Condensate Storage Tank to Pump Suction Isolation Plant ID: E41-MOV F042 Limitorque Model SMB, DC Service, Class B Insulation Service: HPCI Pump Suction Isolation from Torus
- NRC DISCREPANCY Aging Degradation Evaluated Adequately Qualified Life or Replacement Schedule Established A. The licensee has not provided documented evidence from the manufacturer that the installed equipment and the test specimen (s) in the referenced report (s) are similar. The licensee has also not identified any motorized valve actuators that incorporate motor-brake assemblies, yet has referenced reports which tested motorized valve actuators with such devices. The licensee should obtain the information necessary to establish similarity,
/N or submit the same if it is already in their central file (also referencing
(,) B.
this information on the System Component Evaluation Worksheets (SCEWs)).
The licensee has cited B0058 in an effort to establish similarity between the installed equipment and that which has been tested by Limitorque. It should be noted that Limitorque's generic qualification is acceptable, but that this report does not in itself establish similarity, nor does it establish a conservative qualified life for the equipment. In order to establish a qualified life estimate for this equipment, the licensee must completely identify the installed components (i.e. motor lead insulation.)
and then calculate a qualified life based on available information. This available information can come from either testing performed prior to environmental testing or from published data. None of the referenced reports have calculated a qualified life based on an acceptable technique. It should also be noted that the thermal aging that has been performed has been done on individual components or simulates only a fraction of the qualified life claimed. No basis has been stated in the report for the times or temperatures chosen for the thermal aging performed.
However, it is noted that the accident environment is relatively "non-harsh" and that any combination of components which could be found in Linitorque motorized valve actuators should be able to withstand these conditions. Due to this fact, the only deficiency that exists is that of qualified life.
- The service has been expanded to provide clarity.
(G
O TER EQUIPMENT ITEM NO. 17 (Continued)
CLARIFICATION Documented evidence establishing similarity between the. installed equipment and the test specimen is provided by the manufacturer and can be found in Georgia Power Company's Qualification Documentation Files.
Additionally, FRC states that a qualified life has not been established in an acceptable manner. The DOR Guidelines do not require a qualified life to be established for all equipment.
Georgia Power Company has performed further evaluation of age sensitive components and, using available test data and published data, established a qualified life in accordance with the requirements of the DOR Guidelines.
Therefore, this equipment is considered qualified and Justification for Continued Operation is not required.
O O
O TER EQUIPMENT ITEM NO. 18 Motorized Valve Actuator Located in the Torus Room Plant ID: P41-MOV F050 Limitorque Model SMB, AC Service Class H Insulation Service: Service Water Isolation to Drywell Coolers
- Plant ID: P41-MOV F049 Limitorque Model SMB, AC Service, Class H Insulation Service: Service Water Isolation to Drywell Coolers
- Plant ID: Ell-MOV F119A,B Limitorque Model SMB, AC Service, Class H Insulation Service: Residual Heat Removal Exchanger Bypass NRC DISCREPANCY Aging Degradation Evaluated Adequately Qualified Life or Replacement Schedule Established A. The licensee has not provided documented evidence from the manufacturer that the installed equipment and the test specimen (s) in the referenced report (s) are similar. The licensee has also not identified any motorized O valve actuators that incorporate motor-brake assemblies, yet has referenced reports which tested motorized valve actuators with such devices. The licensee should obtain the information necessary to establish similarity, or submit the same if it is already in their central file (also referencing this information on the System Component Evaluation Worksheets (SCEWs)).
B. The licensee has cited B0058 in an effort to establish similarity between the installed equipment and that which has been tested by Limitorque. It should be noted that Limitorque's generic qualification is acceptable, but that this report does not in itself establish similarity, nor does it establish a conservative qualified life for the equipment. In order to establish a qualified life estimate for this equipment, the licensee must completely identify the installed components (i.e. motor lead insulation.)
and then calculate a qualified life based on available information. This available information can come from either testing performed prior to environmental testing or from published data. None of the referenced reports have calculated a qualified life based on an acceptable technique. It should also be noted that the thermal aging that has been performed has been done on individual components or simulates only a fraction of the qualified life claimed. No basis has been stated in the report for the times or temperatures chosen for the thermal aging performed.
- Service has been expanded for clarity.
O V
m ... . . _ . . _ . . _ . _ _ . _ - -
t' TER EQUIPMENT ITEM NO. 18 (Continued)
CLARIFICATION Documented evidence establishing similarity between the installed equipment and the test specimen is provided by the manufacturer and can be found in Georgia
, Power Company's Qualification Documentation Files.
Additionally, FRC states that a qualified life has not been established in an acceptable manner. The D0R Guidelines do not require a qualified life to be established for all equipment.
Georgia Power Company has performed further evaluation of age sensitive i components and, using available test data and published data, established a l
qualified life in accordance with the requirements of the DOR Guidelines.
Therefore, this equipment is considered qualified and Justification for Continued Operation is not required.
O t
O(~'T TER E0UIPMENT ITEM NO. 22 Motorized Valve Actuator Located in the HPCI Room Plant ID: E41-MOV F059 ,
Limitorque Model SMB, DC Service, Class H Insulation Service: HPCI Pump Discharge Isolation to Barometric Condenser Plant ID: E21-MOV F015A,B*
Limitorque Model SMB, DC Service, Class H Insulation Service: Test Bypass Isolation Plant ID: E21-MOV F031A,B*
Limitorque Model SMB, DC Service, Class H Insulation Service: Core Spray Pump Minimum Flow Bypass Isolation NRC DISCREPANCY Aging Degradation Evaluated Adequately Qualified Life or Replacement Schedule Established A. The licensee has not provided documented evidence from the manufacturer that the installed equipment and the test specimen (s) in the referenced
[-~s') report (s) are similar. The licensee has also not identified any motorized
\~ / valve actuators that incorporate motor-brake assemblies, yet has referenced reports which tested motorized valve actuators with such devices. The licensee should obtain the information necessary to establish similarity, or submit the same if it is alre'ady in their central file (also referencing this information on the System Component Evaluation Worksheets (SCZWs)).
B. The licensee has cited B0058 in an effo;t to establish similarity between the installed equipment and that which has been tested by Limitorque. It should be noted that Limitorque's generic qualification is acceptable, but that this report does not in itself establish similarity, nor does it establish a conservative qualified life for the equipment. In order to establish a qualified life estimate for this equipment, the licensee must completely identify the installed components (i.e. motor lead insulation.)
and then calculate a qualified life based on available information. This available information can come from either testing performed prior to environmental testing or from published data. None of the referenced reports have calculated a qualified life based on an acceptable technique. It should also be noted that the thermal aging that has been performed has been done on individual components or simulates only a fraction of the qualified life claimed. No basis has been stated in the report for the times or temperatures chosen for the thermal aging performed.
- The location given for valves is incorrect. The correct location is the Northeast and Southeast Corner Rooms.
v
-_____-____-_-_-____________________-______A
TER EQUIPMENT ITEM NO. 22 (Continued)
However, it is noted that the accident environment is relatively "non-harsh" and that any combination of components which could be found in Limitorque motorized valve actuators should be able to withstand these conditions. Due to this fact, the only deficiency that exists is that of qualified life.
CLARTFICATION Documented evidence establishing similarity between the installed equipment and the test specimen is provided by the manufacturer and can be found in Georgia Power Company's Qualification Documentation Files.
Additionally, FRC states that a cualified life has not been established in an acceptable manner. The DOR Guidelines do not require a qualified life to be established for all equipment.
Georgia Power Company has performed further evaluation of age sensitive components and, using available test data and published data, established a qualified life in accordance with the requirements of the DOR Guidelines.
Therefore, this equipment is considered qualified and Justification for Continued Operation is not required.
O O
TER EOUIPMENT ITEM NO. 24 Motorized Valve Actuator Located in the Northeast and Southeast Corner Rooms Plant ID: Ell-MOV F007A,B Limitorque Model SMB, AC Service Class B Insulation Service: RHR Pump Minimum Flow Bypass Isolation Plant ID: Ell-MOV F006A,B C.D Limitorque Model SMB, AC Service, Class B Insulation Service: RHR Pump Suction Isolation Plant ID: Ell-MOV F004A,B,C,D Limitorque Model SMB, AC Service, Class B Insulation Service: RHR Pump Suction Isolation Plant ID: Ell-MOV F003A,B Limitorque Model SMB, AC Service, Class B Insulation Service: Hx Discharge Isolation Plant ID: Ell-MOV F0llA,B Limitorque Model SMB, AC Service, Class B Insulation Service: RHR Hx Drain to Torus Isolation f~~N Plant ID: Ell-MOV F015B
() Limitorque Model SMB, AC Service, Class B Insulation Service: LPCI Discharge Isolation Plant ID: Ell-MOV F026A,B Limitorque Model SMB, AC Service, Class B Insulation Service: RHR Ex to Reactor Core Cooling Isolation Plant ID: Ell-MOV F048A,B Limitorque Model SMB, AC Service, Class B Insulation Service: RHR Hx Bypass Isolation Plant ID: Ell-MOV F047A,B Limitorque Model SMB, AC Service, Class B Insulation Service: RHR Ex Inlet Isolation Plant ID: Ell-MOV F068A,B Limitorque Model SMB, AC Service, Class B Insulation Service: RHR Service Water Flow Control Plant ID: Ell-MOV F103A,B Limitorque Model SMB, AC Service, Class B Insulation Service: RHR Ex Inlet Isolation O
l (O
O) TER EOUIPMENT ITEM NO. 24 (Continued)
NRC DISCREPANCY Aging Degradation Evaluated Adequately Qualified Life or Replacement Schedule Established A. The licensee has not provided documented evidence frem the manufacturer that the installed equipment and the test specimen (s) in the referenced report (s) are similar. The licensee has also not identified any motorized valve actuators that incorporate motor-brake assemblies, yet has referenced reports which tested motorized valve actuators with such devices. The licensee should obtain the information necessary to establish similarity, or submit the same if it is already in their central file (also referencing this information on the System Component Evaluation Worksheets (SCEWs)).
B. The licensee has cited B0058 in an effort to establish similarity between the installed equipment and that which has been tested by Limitorque. It should be noted that Limitorque's generic qualification is acceptable, but that this report does not in itself establish similarity, nor does it establish a conservative qualified life for the equipment. In order to establish a qualified life estimate for this equipment, the licensee must completely identify the installed components (i.e. motor lead insulation.)and then c available information can come from either testing performed prior to environmental testing or from published data. None cf the referenced reports r~ have calculated a qualified life based on an acceptable technique. It should Q] also be noted that the thermal aging that has been performed has been done on individual components or simulates only a fraction of the qualified life claimed. No basis has been stated in the report for the times or temperatures chosen for the thermal aging performed.
However, it is noted that the accident environment is relatively "non-harsh" and that any combination of components which could be found in Limitorque motorized valve actuators should be able to withstand these conditions. Due to this fact, the only deficiency that exists is that of qualified life.
p ARIFICATION Documented evidence establishing similarity between the installed equipment and the test specimen is provided by the manufacturer and can be found in Georgia Power Company's Qualification Documentation Files.
Additionally, FRC states that a qualified life has not been established in an acceptable manner. The D0R Guidelines do not require a qualified life to be established for all equipment.
Georgia Power Company has performed further evaluation of age sensitive components and, using available test data and published data, established a qualified life in accordance with the requirements of the D0R Guidelines.
Therefore, this equipment is considered qualified and Justification for Continued Operation is not required.
O V
O TER E0l'IPMENT ITEM NO. 39 Solenoid Valve Located Inside Containment Plant ID: B21-A0V F013A,C.E.F,J,K,L Target Rock Model 1/2 SMS-A-01-1 Service: Automatic Depressurization System NRC DISCREPANCY Qualified Life or Replacement Schedule Established Criteria Regarding Aging Simulation Satisfied.
- 1. The Licensee references the aging analysis performed by Target Rock as Appendix I of TRC 2063B as evidence of qualification for a 5 year replacement interval for this equipment. It is noted, however, that the test report summary did not present any evidence that the thermal aging time and temperature exposure was performed during the test program.
- 2. The radiation cr teria has not been met. A conservative qualified life estimate dictated by the Licensee's plant specific application aging analysis (provided the thermal aging of Appendix I mentioned above was performed) should alleviate this problem by reducing the radiation absorbed
/G during normal life.
b CLARIFICATION The Target Rock Test Report provides a list of the non-metallic materials in the solenoid valve, of which there are two (2): Polyimide and Silicon Rubber.
The solenoid valves were aged for 480 hours0.00556 days <br />0.133 hours <br />7.936508e-4 weeks <br />1.8264e-4 months <br /> @ 285* F which was based on the 10' C rule. (The calculation is shown in Appendix I of the Test Report.) Georgia Power Company has performed calculations using the above test data, plant specific temperatures, and the Arrehenius Equation to demonstrate a qualified life of 10 years for the silicon rubber 0-rings and gasket and 40 years for the polyimide.
The solenoid vaives were exposed to 3.26 x 10 radspuringtesting.7However, theplantspecifictotalintegrateddoseja4.4x10 rads (1.8 x 10 rads for l
40 years of normal operation and 2.6 x 10 rads for accident dose).
The radiation threshold of silicon rubber is less than 4.4 x 10 rads, 7
therefore, the silicon rubber shall not be exposed to more than 3.26 x 10 rads.
! Georgia Power Company has performed a calculation which demonstrates that i
replacing the 0-ringy every ten (10) years will keep the total integrated dose less than 3.26 x 10 rads.
Based on the above, Georgia Power Company has established a qualified life based i on methods acceptable to the NRC.
I
O TER EQUIPMENT ITEM NO. 51 Solenoid Valve Located Inside Containment Plant ID: E21-A0V F006A,B (E21-A0V F037A,B)
ASCO Model NP8344A73A Service: Core Spray Pump Discharge Isolation NRC DISCREPANCY Qualified Life or Replacement Schedule Established The NRC has stated that a specific qualified life has not been established for this equipment using plant specific parameters.
CLARIFICATION The manufacturer recommends replacement of non-metallic parts every four (4) years based on the results'of the Qualification Tests. Georgia Power Company has established a qualified life of greater than four (4) years based on activation energies of the non-metallic materials obtained from ASCO, the aging test time and temperature, plant specific normal temperatures, and the Arrhenius equation. However, Georgia Power Company is following the manufacturer's
( recommendations.
In accordance with the NRC recommendation, the replacement solenoid valves have been sealed at the conduit entrance with qualified materials which prevent moisture from entering the solenoid valve.
U
i b TER EOUIPMENT ITEM NO. 57 Limit Switches located inside Containment Plant ID: B21-A0V F022A,B,C.D NAMCO Model EA740-80000/EA740-80001 Service: Main Steam Line Isolation Plant ID: B21-A0V F028A,B.C D NAMCO Model EA740-80000/EA740-80001 Service: Main Steam Line Isolation NRC DISCREPANCY Aging Degradation Evaluated Adequately Qualified Life or Replacement Schedule Established
" Heat aging. The heat aging test consisted of holding the unit suspended over water in a tank at a temperature of 200*F for 200 hours0.00231 days <br />0.0556 hours <br />3.306878e-4 weeks <br />7.61e-5 months <br /> +
+ Heat aging conditions were taken from ANSI Draft Standard N278.2.1 (Draft
- 3. Rev. 0). The correlation between these conditions and the qualified life is not known.
[\' The licensee has referred to an " estimation of qualified life of EA740 Series Nuclear Switch" dated 2/27/1980. This NAMCO Report provides an estimated qualified life of 4.0 years at 104*F, assuming an activation energy of 0.958 eV for the NBR gasket material. The SCEW sheet states that the specified ambient temp. is 135*F. No estimation of qualified life at the specified service temperature is provided.
CLARIFICATION l Georgia Power Company has replaced these limit switches with upgraded limit switches of the same model but which are qualified per NAMCO Report QTR-lll.
The qualification report provides a temperature versus time curve based on the l test time and temperature and the Arrhenius equation. Georgia Power Company has established a qualified life for these switches using this curve.
In accordance with the NRC recommendation, the replacement limit switches have been sealed at the conduit entrance with qualified materials which prevent moisture from entering the limit switch, i
l J
L. J
l (3
TER EQUIPMENT ITEM NO. 179 Motorized Valve Actuator Located in the Torus Room Plant ID: P42-MOV F052 Limitorque Model SMB, AC Service, Class H Insulati Service: RBCCW Isolation from Primary Containment Plant ID: P42-MOV F051 Limitorque Model SMB, AC Service, Class H Insulation Service: RBCCW Isolation to Primary Containment NRC DISCREPANCY Aging Degradation Evaluated Adequately Qualified Life or Replacement Schedule Established A. The licensee has not provided documented evidence from the manufacturer that the installed equipment and the test specimen (s) in the referenced report (s) are similar. The licensee has also not identified any motorized valve actuaters that incorporate motor-brake assemblies, yet has referenced reports which tested motorized valve actuators with such devices. The licensee should obtain the information necessary to establish similarity,
("N or submit the same if it is already in their central file (also referencing i this information on the System Component Evaluation Worksheets (SCEWs)).
B. The licensee has cited B0058 in an effort to establish similarity between the installed equipnent and that which has been tested by Limitorque. It should be noted that Limitorque's generic qualification program is acceptable, but that this report does not in itself establish similarity, nor does it establish a qualified life estimate for this equipment. In order to establish a conservative qualified life for the equipment, the licensee must completely identify the installed components (i.e. motor lead insulation) and then calculate a qualified life based on available information. This available information can come from either testing performed prior to envfronmental testing or from published data. None of the referenced reports have calculated a qualified life based on an acceptable technique. It should also be noted that the thermal aging that has been performed has been done on individual components or simulates only a fraction of the qualified life claimed. No basis has been stated in the report for the times or temperatures chosen for the thermal aging performed.
CLARIFICATION Documented evidence establishing similarity between the installed equipment and the test specimen is provided by the manufacturer and can be found in Georgia Power Company's Qualification Documentation Files.
O U
TEF EQUIPMENT ITEM NO. 179 (Continued)
Additionally, FRC states that a qualified life has not been established in an acceptable manner. The DOR Guidelines do not require a qualified life to be i established for all equipment.
Georgia Power Company has performed further evaluation of age sensitive components and, using available test data and published data, established a qualified life in accordance with the requirements of the D0R Guidelines.
Therefore, this equipment is considered qualified and Justification for Continued Operation is not required.
O 4
4 O
U
i O
TER EQUIPMENT ITEM NO. 180 Motorized Valve Actuator Located in the Northeast and Southeast Corner Rooms Plant ID: Ell-MOV F104A,B Limitorque Model SMB, AC Service, Class H Insulation Service: RHR Hx Ventilation Isolation NRC DISCREPANCY Aging Degradation Evaluated Adequately Qualified Life or Replacement Schedule Established A. The licensee has not provided documented evidence from the manufacturer
! that the installed equipment and the test specimen (s) in the referenced report (s) are similar. The licensee has also not identified any motorized valve actuators that incorporate motor-brake assemblies, yet has referenced
- reports which tested motorized valve actuators with such devices. The licensee should obtain the information necessary to establish similarity,
- or submit the same if it is already in their central file (also referencing this information on the System Component Evaluation Worksheets (SCEWs)).
l B. The licensee has cited B0058 in an effort to establish similarity between O the installed and equipment and that which has been tested by Limitorque.
It should be noted that Limitorque's generic qualification is acceptable, but that this report does not in itself establish similarity, nor does it establish a qualified life estimate for this equipment. In order to establish a conservative qualified life estimate for this equipment, the licensee must completely identify the installed components (i.e. motor lead insulation) and then calculate a qualified life based on available information. This available information can come from either testing performed prior to environmental testing or from published data. None of the referenced reports have calculated a qualified life based on an acceptable technique. It should also be noted that the thermal aging that has been performed has been done on individual components or simulates only a fraction of the qualified life claimed. No basis has been stated in the report for the times or temperatures chosen for the thermal aging performed.
However, it is noted that the accident environment is relatively "non-harsh" and that any combination of components which could be found in Limitorque motorized valve actuators should be able to withstand these conditions. Due to this fact, the only deficiency that exists is that of qualified life.
i i
O
-_-= - . --
(D V
y EQUIPMENT ITEM NO. 180 (Continued)
CLARITICATION Documented evidence establishing similarity between the installed equipment and the test specimen is provided by the manufacturer and can be found in Georgia Power Company's Qualification Documentation Files.
Additionally, FRC states that a qualified life has not been established in an acceptable manner. The D0R Guidelines do not require a qualified life to be established for all equipment.
Georgia Power Company has performed further evaluation of age sensitive components and, using available test data and published data, established a qualified life in accordance with the requirements of the DOR Guidelines.
Therefore, this equipment is considered qualified and Justification for Continued Operation is not required.
i 2
O
SECTION D OPEN ITEM EQUIPMENT LIST INTRODUCTION This section provides, per the requirements of 10C'FR50.49, Paragraph (g), a list of electrical equipment important to safety, which has not yet been environmentally qualified by Georgia Power Company.
The equipment is identified by the TER Equipment Item Number (if applicable) and associated Plant Identification Number, followed by the Equipment Location, Equipment Description, and the Equipment Service.
The Corrective Action for resolving the Open Item and a schedule for completing that action is provided for the equipment.
The schedules provided for resolving the open items meet the requirements of 10CFR50.49, Paragraph (g).
l O
l 1
O t
L 9 I
TABLE D-1 >
7 t' '
OPEN ITEM EQUIPMENT LIST F
TER EQUIPMENT ITEM NO.: 2 Plant ID: E41-MOV F003 -
9 Motorized Valve Actuator Located in the Pipe Penetration Room i Limitorque Model SMB, Cless B Insulation '
/.
Service: Steam Supply Isolation -
CORRECTIVE ACTION: The motor for this motor operated valve will be replaced' ' '
with a qualified motor. prior to or during the Unit 1, 1984 Refueling Outage. '
?
. ,l TER EQUIPMENT ITEM No.: 3 Plant ID: B21-MOV F019 ' '
Motorized Valve Actuator Located in the Pipe Chase Limitorque Model SMB, DC Service, Class H Insulation Service: Drain Isolation CORRECTIVE ACTION: Tt.e motor for this motor operated valve will be replaced with a qualified motor prior to or during.the Unit 1, 1984 Refueling Outage.
f TER EQUIPMENT ITEM NO.: 6 Plant ID: E51-MOV F031 Motorized Valve Actuator Located in the Southwest Corner Room (RCIC)
Limitorque Model SMB, DC Service, Class B Insulation Service: RCIC Pump Suction Isolation from Torus CORRECTIVE ACTION: The motor for this untor operated valve will be replaced with a qualified motor prior to or during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 10 Plant ID: B31-MOV F031A,B Motorized Valve Actuator Located in the Containment Limitorque Model SMB 3. AC Service, Class H Insulation Service: Recirculation Pump Discharge Isolation '
CORRECTIVE ACTION: The actuator and motor for this motor operated valve will be replaced with a qualified actuator.and motor prior to or during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 13
Plant ID: G31-MOV F001 Motorized Valve Actuator Located in the Containment
Limitorque Model SMB, AC Service I i Service: RWCU Pump Suction Isolation CORRECTIVE ACTIbN: The motor for this motor operated valve will be replaced with a qualified motor prior to or during the Unit 1, 1984 Refueling Outage.
J r - , ,-,,,y---,-e~ .. - - -, - , - - , .-
e
, s
, 'y a > '
..T C\
TER EOUIPMENT ITEM NO.: 13
- ' Plant ID: Ell-MOV F022 Motorized Valve Actuator Located in the Containment Limitorque Model SMB, AC Service Service: Vessel Head Spray Heater Isolation CORRECTIVE ACTION: The notor for this motor operated valve will be replaced with a qualified motor prior to or during the Unit 1, 1984 Refueling Outage.
, TER EQUIPMEl;T ITEM NO.: 14 Plant ID: Ell-MOV F009 Motorized Valve Actuator Located in the Containment Limitorque.Model SMB, AC Service, Class H Insulation Service: Shutdown Cooling Suction Isolation CORRECTIVE ACTI N: The actuator and motor for this motor operated valve will be replaced with a qualified actuator and motor prior to or during the Unit 1, 1984 Refueling Outage.
.TER EQUIPMENT ITEM No.: 15 i Plant ID: E21-MOV F005A,E Hotorized Valve Actuator Located in the Reactor Building, Elev. 158' 0" Limitorque Model SMB, AC Service, Class B Insulation
,- ' Se rvice: Core Spray Pump Discharge Isolation
-- CORRECTIVE ACTION: The actuator and motor for this motor operated valve will be replaced with a qualified actuator and motor prior to or during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 15
- Plant ID: E21-MOV F004A,B'
< Notorized Valve Actuator Located in the Reactor Building, Elev. 158' 0" i
Limitorque Model SMB, AC Service, Class B Insulation l Service: Core Spray Pump Discharge Isolation
! - .u .
CO'RRECTIVE'A b TION: Ite actuator and motor for this motor operated valve will be replaced with/a qualified actuator and motor prior to or during the Unit 1, 1984 Refueling Outage.
l , -
l TER. EQUIPMENT ITEM NO.: 16 i Plant ID: E41-110V F041 Motorized Valve Actuator Located in the HPCI Room Limitorque Model SMB, DC Service, Class B Insulation Service: HFCI Pump Suction Isolation from Torus CORRECTIVE ACTION: The motor for this motor operated valve will be replaced l with a qualified motor prior to or during the Unit 1, 1984 Refueling Outage.
i F ss f% t
~
'd l
i l .
t
[ h
\~-)
TER EOUIPMENT ITEM NO.: 16 Plant ID: E51-MOV F008
+
Motorized Valve Actuator Located in the Pipe Chase
,Limitorque Model SMB, DC Service,' Class B Insulation Service: Steam Supply Isolation CORRECTIVE ACTION: The motor for this motor operated valve will be replated with a qualified motor prior to or during the Unit 1,~1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 16 Plant ID: G31-MOV F004 Motorized Valve Actuator Located it. the Reacter Building, Elev 158' 0" '
Limitorque Model SMB, DC Service, Class B Insulation Service: Reactor Water Cleanup Pump Suction Isolation CORRECTIVE ACTION: The motor for this motor operated valve will be replaced with a qualified motor prior to or during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 19 Plant ID: Ell-MOV F021A,B' Motorized Valve Actuator Located in the Reactor Water Cleanup Pump. Room Limitorque Model SMB, AC Service, Class F Insulation Service: Containeenc Spray Discharge Isolation ,
[ h ; CORRECTIVE ACTION: The actuator and motor for this motor operated' valve will be
\~ I replaced with a qualified actuator and motor prior to or during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 21 Plant ID: E41-MOV F001 Motorized Valve Actuator Located in the High Pressure Coolant Injection Room Limitorque Model SMB, DC Service, Class B Insulation Service: Turbine Steam Supply Isointion CORRECTIVE ACTION: The motor for this motor operated valve will be replaced '
with_a qualified motor prior to or during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 21 Plant ID: E41-MOV F012 Matorized Valve Actuator Located in the High Pressure Coolant Injection Room Limitorque Model SMB, DC Service, Class B Insulation Service: Minimum Flow Bypass CORRECTIVE ACTION': The notor'for this motor operated valve will be replaced
~
t with a qualified motor prior to or during the Unit 1,1984 Refueling Outage.
7 (_ /
' {: /
8
O TER EQUIPMENT ITEM No.: 21 Plant ID: E41-MOV P011 Motorized Valve Actuator Located in the High Pressure Coolant Injection Room Limitorque Model SMB, DC Service, Class B insulation -
Service: Test Bypass Valve to Condensate Storage CORRECTIVE ACTION: The motor for this motor operated valve will be replaced with a qualified motor prior to or during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 70 Plant ID: T41-TIS N022A,B Temperature Switch Located in the RCIC (SW) Corner Room Honeywell Model T654A1560 Service: RCIC Pump Room Cooler CORRECTIVE ACTION: The temperature indicating switch will be replaced with qualified PYCO temperature elements and qualified Sigma temperature indicating switches (located in the Main Control Room) during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 71 Plant ID: T41-TIS N019A,B Temperature Switch Located in the HPCI Room Honeywell Model T654A1560 Service: RPCI Pump Room Cooler CORRECTIVE ACTION: The temperature indicating switch will be replaced with qualified PYC0 temperature elements and qualified Sigma temperature indicating switches (located in the Main Control Room) during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 71 Plant ID: T41-TIS NO20A,B Temperature Switch Located in the SE Corner Room Honeywell Model T654A1560 Service: RHR/ Core Spray Pump Room Cooler CORRECTIVE ACTION: The temperature indicating switch will be replaced with qualified PYC0 temperature elements and qualified Sigma temperature indicating switches (located in the Main Control Room) during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 71 Plant ID: T41-TIS NO21A,B Temperature Switch Located in the NE Corner Room Honeywell Model T654A1560 Service: RHR/ Core Spray Pump Room Cooler CORRECTIVE ACTION: The temperature indicating switch will be replaced with qualified PYC0 temperature elements and qualified Sigma temperature indicating switches (located in the Main Control Room) during the Unit 1, 1984 Refueling Outage.
1
t TER EQUIPMENT ITEM No.: 72 Plant ID: E41-PS N010 Pressure Switch Located in the HPCI Room Static-0-Ring Model 6NAA21X10SITT Service: HPCI Pump Suction Low Pressure Panel H21-P014 CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 72 Plant ID: E41-PS N012A,B.C.D Pressure Switch Located in the HPCI Room Static-0-Ring Model 6NAA2X10SITT Service: Turbine Exhaust Ventilation CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 72 Plant ID: E41-PS N017A,B
/ t Pressure Switch Located in the HPCI Room
\s ) Static-0-Ring Model SNAA3X10SITT Service: HPCI Turbine Exhaust High Pressure Panel H21-P014 CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 73 Plant ID: C71-PS N002A,B,C D Pressure Switch Located in ihe Reactor Building, Elev. 158' 0" Static-0-Ring Model 12NBB4NX Service: Primary Containment High Pressure CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage.
O V
TER EQUIPMENT ITEM NO.: 74 Plant ID: E41-DPIS N005 Differential Pressure Indicating Switch Located in the Reactor Building, Elev.
130' 0" Barton Model 288 Service: HPCI Steam Line High Pressure Panel H21-r036 CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog i Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage.
l TER EQUIPMENT ITEM NO.: 74 Plant ID: E41-DPIS N004 Differential Pressure Indicating Switch Located in the Reactor Building, Elev.
130' 0" Barton Hodel 288 Service: HPCI Steam Line Low Pressure Panel H21-P016 CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the
() Unit 1, 1984 Refueling Outage.
TER EQUIPMEN" ITEM No.: 75 Plant ID: Ell-PS N016B,D Pressure Switch Located in the Northeast Corner Room Static-0-Ring Model SNAA3X10SITT Service: Pump Discharge Pressure Panel H21-P021 CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or durin; the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 75 Plant ID: Ell-PS N020B,D Pressure Switch Located in the Northeast Corn.er Room Static-0-Ring Model 5NAA3X10SITT Service: Pump Discharge Pressure Panel H21-P021 CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage.
O TER EQUIPMENT ITEM No.: 75 Plant ID: E21-PS N008A,B Pressure Switch Located in the Northeast Corner Room Static-0-Ring Model SNAA3X10SITT Service: Core Spray Pump Discharge CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 76 Plant ID: B21-DPIS N006A,B,C.D D/P Indicating Switch Located in the Reactor Building, Elev. 130' 0" Barton Model 288 Service: Main Steam Line High Flow CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 76 Plant ID: B21-DPIS N009A,B,C,D g'- ' D/P Indicating Switch Located in the Reactor Building, Elev. 130' 0" Barton Model 288 Service: Main Steam Line High Flow CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 76 -
Plant ID: B21-DPIS N008A,B C.D D/P Indicating Switch Located in the Reactor Building, Elev. 130' 0" Barton Model 288 Service: Main Steam Line High Flow CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the 4
Unit 1, 1984 Refueling Outage.
O TER EQUIPMENT ITEM NO.: 76
-Plant ID: B21-DPIS N007A,B.C D D/P Indicating Switch Located in the Reactor Building, Elev. 130' 0" Barton Model 288 Service: Main Steam Line High Flow CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 76 Plant ID: B21-PS N021C Pressure Switch Located in the Reactor Building, Elev. 130' 0" Barton Model 288 Service: Vessel Pressure CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 76 Plant ID: B21-PS N021B 9 Pressure Switch Located in the Reactor Building, Elev.
Barton Model 288 Service: Vessel Pressure 158' 0" CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a quelified Gereral Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 76 Plant ID: E51-DPIS N018 D/P Indicating Switch Located in the Reactor Building, Elev. 130' 0" Barton Model 288 Servi e: Steam Line High Differential Pressure Panel H21-P038 CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage.
O
v TER EQUIPMENT ITEM NO.: 76 Plant ID: E51-DPIS N017 D/P Indicating Switch Located in the Reactor Building, Elev. 130' 0" Barton Model 288 Service: Steam Line High Differential Pressure Panel H21-P035 CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 77 Plant ID: Ell-PS N010A,B,C D Pressure Switch Located in the Reactor Building, Elev. 158' 0" Static-0-Ring Model 12NAA5X9TT Service: Automatic Initiation Drywell High Pressure CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 77 Plant ID: Ell-PS N0llA,B,C.D (f-~s) Pressure Switch Located in the Reactor Building, Elev. 158' 0" N- ' Static-0-Ring Model 12NAA5X9TT Service: Automatic Initiation Drywell High Pressure CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Antlog Transmitter Trip System (ATTS). ATTS will be installed prior to or duri,g the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 78 Plant ID: B21-LITS NO37 Level Indicating Switch Located in the Reactor Building, Elev. 130' 0" Yarway Model 4418CE Service: Level in Shroud-RHR Initiation Panel H21-P009 CORRECTIVE ACTION: The switch will be replaced with a qualified' Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to er during the Unit 1, 1984 Refueling Outage.
(D V
- - - - - - - - _ _ _ - - - _ - - - - - _ __-__-_ -_ __--_-_ _ ---_- a
G TER E0UIPMENT ITEM NO.: 78 Plant ID: B21-LIS N042A,B Level Indicating Switch Located in the Reactor Building, Elev. 158' 0" Yarway Model 4418C Service: Automatic Blowdown Permissive CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 78 Plant ID: B21-LIS NO24A,B Level Indicating Switch Located in the Reactor Building Elev. 158' 0" Yarway Model 4418C Service: Scram-Primary Containment Isolation Panel H21-P004 CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 78 Plant ID: B21-LIS N025A,B
/' Level Indicating Switch Located in the Reactor Building, Elev. 158' 0" k_-
s Yarway Model 4418C Service: Scram-Primary Containment Isolation Panel H21-P005 CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 78 Plant ID: B21-LITS N026A,B Level Indicating Switch Located in the Reactor Building Elev. 158' 0" Yarway Model 4418CE Service: Reactor Water Level - RCIC CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 1 1984 Refueling Outage.
(
m_ --,
G/
TER EQUIPMENT ITEM NO.: 78 Plant ID: B21-LIS NO31A,B,C,D Level Indicating Switch Located in the Reactor Building, Elev. 158' 0" Yarway Model 4418C Service: Initiate kCIC, HPCI & RHR CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 78 Plant ID: B21-LITS N036 Level Indicating Switch Located in the Reactor Building, Elev. 130' 0" Yarway Podel 4418CE Service: Level in Shroud-RHR Initiation Panel H21-P010 CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 79 Plant ID: Ell-DPIS N021A,B
( D/P Indicating Switch Located in the Northeast and Southeast Corner Rooms
\- Barton Model 289 Service: RHR Pump Discharge Minimum Flow CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 79 Plant ID: E21-FIS N006A,B Flow Indicating Switch Located in the Northeast and Southeast Corner Rooms Barton Model 289 Service: Pump Outlet Flow CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage.
()\
L
l b
v TER EQUIPMENT ITEM NO.: 79 Plant ID: E41-FS N006 Flow Switch Located in the HPCI Room Barton Model 289 Service: Pump Discharge High/ Low Flow Panel H21-P104 CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 80 Plant ID: B21-LIS N017A,B C D Level Indicating Switch Located in the Reactor Building, Elev. 158' 0" Barton Model 288A Service: HPCI & RCIC Turbine CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analcg Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 81 Plant ID: B21-PS NO21A,E
[ ) Pressure Switch Located in the Reactor Building, Elev. 158' 0"
\J Barksdale Model B2TM12SS Service: Vessel Pressure CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 81 Plant ID: B21-PS N021D,F Pressure Switch Located in the Reactor Building, Elev. 130' 0" Barksdale Model B2TM12SS Service: Vessel Pressure CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage.
v
l
b) TER EQUIPMENT ITEM NO.: 82 Plant ID: E41-PS N027 Pressure Switch Located in the HPCI Room Barksdale Model B2TM12SS Service: Pump Discharge Pressure Panel H21-P014 CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 82 Plant ID: Ell-PS N020A,C Pressure Switch ~ Located in the Southeast Corner Room Barksdale Model B2TM12SS Service: Pump Discharge Pressure CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 82 Plant ID: Ell-PS N016A.C
( Pressure Switch Located in the Southeast Corner Room Barksdale Model B2TM12SS Service: Pump Discharge Pressurizer CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 82 Plant ID: E21-PS N009A,B Pressure Switch Located #n the Northeast and Southeast Corner Rooms Barksdale Model B2TM12SS Service: Core Spray Pump Discharge CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage.
~>
TER EQUIPMENT ITEM NO.: 82 Plant ID: E41-PS N001A,B.C,D Pressure Switch Located in the Reactor Building, Elev. 130' 0" Barksdale Model B2TM12SS Service: HPCI Low Pressure Isolation CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM No.: 82 Plant ID: E51-PS N019A,B,C,D Pressure Switches Located in the Reactor Bui1. ding, Elev. 130' 0" Barksdale Model B2TM12SS Service: Steam Line Low Pressure CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 83 Plant ID: E41-LS N015A,B Level Switch Located in the Torus Room
[\-)/ Robertshaw Model 83842A2 Service: Suppression Pool Level CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 84 Plant ID: T41-FS N005A,B Flow Switch Located in the HPCI Room Dietz Model 130DIMAS Service: HPCI Pump Room Cooler CORRECTIVE ACTION: Georgia Power Company is performing a documentation search to obtain additional data on the diaphragm material in order to address the effects of aging and radiation. The documentation search and any required analysis will be completed by no later than the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 84 Plant ID: T41-FS N004A,B Flow Switch Located in the RCIC (SW) Corner Rcom Dietz Model 130DIMAS Service: RCIC Pump Room Cooler CORRECTIVE ACTION: Georgia Power Company is performing a documentation search to obtain additional data on the diaphragm material in order to address the effects of aging and radiation. The documentation search and any required analysis will be completed by no later than the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 84 Plant ID: T41-FS N003A B Flow Switch Located in the Northeast Corner Room Dietz Model 130DIMAS Service: RHR/ Core Spray Pump Room Cooler CORRECTIVE ACTION: Georgia Power Company is performing a documentation search to obtain additional data on the diaphragm material in order to address the effects of aging and radiation. The documentation search and any required analysis will be completed by no later than the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 84 Plant ID: T41-FS N002A,B Flow Switch Located in the Southeast Corner Room
( Dietz Model 130DIMAS Service: RHR/ Core Spray Pump Room Cooler CORRECTIVE ACTION: Georgia Power Company is performing a documentation search to obtain additional data on the diaphragm material in order to address the effects of aging and radiation. The documentation search and any required analysis will be completed by no later than the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM No.: 84 Plant ID: T46-FS N0llA,B Flow Switch Located in the Reactor Building, Elev. 164' 0" Dietz Medel 130DIMA5 Service: Standby Cas Treatment Fan CORRECTIVE ACTION: Georgia Power Company is performing a documentation search to obtain additional data on the diaphragm material in order to address the ,
effects of aging and radiation. The documentation search and any required analysis will be completed by no later than the Unit 1,1984 Refueling Outage.
O
O
\~. J TER EQUIPMENT ITEM No.: 85 Plant ID: T48-DPS N210 D/P Switch Located in the Torus Room
! Barksdale Model DPD2TA3 Service: Primary Containment Purge Vacuum Breakers CORRECTIVE ACTION: The switch will be replaced with a qualified Rosemount Type 1153 transmitter (located in the Torus Room) and a Foxboro trip card (located in
- the Main Control Room) during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 85 Plant ID: T48-DPS N211 D/P Switch Located in the Torus Roon Barksdale Model DPD2TA3 Service: Primary Containment Purge Vacuum Breakers CORRECTIVE ACTION: The switch will be replaced with a qualified Rosemount Type 1153 transmitter (located in the Torus Room) and a Foxboro trip card (located in the Main Control Room) during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.': 86 Plant ID: E51-PS N012A,B,C D Pressure Switch Located in the RCIC (Sk')
s Earksdale Model D2HA150SS i Service: Turbine Exhaust Diaphragm CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 94 Plant ID: E41-C002 Turbine Located in the HPCI Room Terry Model CCS Service: HPCI System CORRECTIVE ACTION: An analysis, of the equipment associated with the HPCI turbine and required to mitigate the consequences of an accident, was performed i to determine the equipment for which qualification could be established.
Equipment, whose qualification cannot be established, will be replaced or relocated during the Unit 1, 1984 Refueling Outage.
+ + - -e - - - - - - -- -p - -- . - % ?+ +
O TER EQUIPMENT ITEM NO.: 97 Plant ID: Panel Board in MCC R24-S011/S012 Panel I&C Located in the Reactor Building, Elev. 130' 0" Westinghouse Model WEHB CKT BKR ERB Service: Power for P33-P001A/B only CORRECTIVE ACTION: The power distribution for the replacement H and 0 2
analyzers (see TER item No. 99) will be provided by transformers2and panelboards located in a mild environment. These transformers and panel boards will be replaced during the Unit 1, 1984 Refueling Outage. The transformers under TER Equipment Item No. 101 and the panel boards under TER Equipment Item No. 97 will not be required.
TER EQUIPMENT ITEM NO.: 98 Plant ID: T48-ROV F112A,B Hydraulic Operated Valve Located in the Reactor Building, Elev. 130' 0" Fisher Controls Model 350 Service: Nitrogen Makeup Control CORRECTIVE ACTION: The hydraulic operated valve (HOV) will be replaced with a Dragon Needle valve during the Unit 1, 1984 Refueling Outage. The valve and the instruments used in the flow control system for the valve will be deleted from the I. E. Bulletin 79-01B equipment list after replacement of the valve because-the needle valve is mechanical equipment, not Class 1E equipment.
TER EQUIPMENT ITEM NO.: 99 Plant ID: P33-P001A,B Hydrogen-Oxygen Analyzer Located in the Reactor Building, Elev. 158' 0" Hays Model E632II 0, Analyzer, SH643D H, Analyzer Service: Primary Containment Atmosphefe 2H and 02 Analyzer CORRECTIVE ACTION: The 2 H and 2
0 analyzer will be replaced with a qualified Comsip Type K-IV3H and 20 analyzer during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 101 Plant ID: R11-S039/R11-SO40 Transformer Located in the Reactor Building, Elev. 130' 0" Sorgel Model Serial No. 101023-5 Service: Power for P33-P001A/B Only CORRECTIVE ACTION: The power distribution for the replacement H and 0 analyzers (see TER item No. 99) will be provided by transformers 2and panelboards 2 located in a mild environment. These transformers and panelboards will be replaced during the Unit 1, 1984 Refueling Outage. The transformers under TER Equipment Item No. 101 and the panel boards under TER Equipment Item No. 97 will not be required.
s
TER EQUIPMENT ITEM NO.: 107 Plant ID: Ell-FT N015A,B Flow Transmitter Located in the Northeast / Southeast Corner Rooms Barton Model 368 Service: RHR Flow CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 108 Plant ID: C32-PT N005A,B Pressure Transmitter Located in the Reactor Building, Elev. 158' 0" GE/MAC Model 551032GKZZ2556 Service: Reactor Pressure CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog E
Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM No.: 109 Plant ID: B21-LT N027 Level Transmitter Located in the Reactor Building, Elev. 158' 0"
(,}/
/
_ GE/MAC Model 555111BDAA3PDF Service: Vessel Water Level Wide Range CORRECTIVE ACTION: The transmitter will be replaced with a qualified Barton transmitter as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM No.: 110 Plant ID: E41-FT N008 Flow Transmitter Located in the HPCI Room GE/MAC Model 555111BDAA4WAL Service: Pump Discharge flow Panel H21-P014 CORRECTIVE ACTION: The transmitter will be replaced with a qualified Barton transmitter as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 110 Plant ID: E21-FT N003A,B Flow Transmitter Located in the HPCI Room Bailey Meter Model 555111BDAA4WAL Service: Pumps Outlet Flow CORRECTIVE ACTION: The transmitter will be replaced with a qualified Barton transmitter as part of the Analog Transmitter Trip System (ATTS). ATTS will be
() installed prior to or during the Unit 1, 1984 Refueling Outage.
TER EOUIPMENT ITEM NO.: 112 Plant ID: T48-PT N001 Pressure Transmitter Located in the Reactor Building, Elev. 130' 0" GE/MAC Model 551 Service: Ny Makeup to Drywell and Torus CORRECTIVE ACTION: The transmitter will be replaced with a qualified Rosemount Type 1153 transmitter during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 114 Plant ID: Ell-DPT N002A,B D/P Transmitter Located in the Northeast and Southeast Corner Rooms Rosemount Model 1151DP7B22MB Service: Hest Exchanger Shell to Tube CORRECTIVE ACTION: The transmitter will be replaced with a qualified Barton transmitter as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 115 Plant ID: G31-FT N012 Flow Transmitter Located in the Reactor Building, Elev. 158' 0" GE/MAC Model 555111BCAA4WAK
~~ Service: Blowdown Flow Panel H21-P002 ss CORRECTIVE ACTION: The transmitter will be replaced with a qualified Barton ,
transmitter as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 115 Plant ID: G31-FT NO36 Flow Transmitter Located in the Reactor Puilding, Elev. 158' 0" GE/MAC Model 555111BCAA4WAK Service: Inlet Flow Panel H21-P002 CORRECTIVE ACTION: The transmitter will be replaced with a qualified Barton transmitter as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM No.: 115
. Plant ID: G31-FT N041 Flow Transmitter Located in the Reactor Building, Elev. 158' 0" GE/MAC Model 555111BCAA4WAK Service: Outlet Flow Panel H21-P002 CORRECTIVE ACTION: The transmitter will be replaced with a qualified Barton transmitter as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage.
I s _-
i V
TER EQUIPMENT ITEM NO.: 118 Plant ID: T48-E/S K011A,B Power Supply Located in the Reactor Building, Elev. 130' 0" Brooks Model 5523DX Service: Nitrogen Makeup Control CORRECTIVE ACTION: The hydraulic operated valve (HOV) will be replaced with a Dragon needle valve during the Unit 1, 1984 Refueling Outage. The valve and the instruments used in the flow control system for the valve will be deleted from I. E. Bulletin 79-01B equipment list after replacement of the valve because the needle valve is mechanical equipment, not Class 1E equipment.
TER EQUIPMENT ITEM NO.: 119 Plant ID: T48-FIT N014A,B Flow Indicating Transmitter Located in the Reactor Building, Elev. 130' 0" Brooks Model 3611 Service: Nitrogen Makeup Control CORRECTIVE ACTION: The hydraulic operated valve (HOV) will be replaced with a Dragon needle valve during the Unit 1, 1984 Refueling Outage. The valve and the instruments used in the flow control system for the valve will be deleted from I. E. Bulletin 79-01B equipment list after replacement of the valve because the needle valve is mechanical equipment, not Class 1E equipment.
O TER EQUIPMENT ITEM NO.: 120 Plant ID: T48-E/S K001 Power Supply Located in the Reactor Building,, Elev. 158' 0" GE Model 570062FAAC1 Service: N Makeup to Drywell and Torus 2
CORRECTIVE ACTION: The power supply will be replaced with a qualified Foxboro power distribution module during the Unit 1, 1984 Refueling Outage. The qualified power distribution module will be located in the Main Control Room which is a non-harsh environment. Therefore, this power supply will then be deleted from the I.E. Bulletin 79-01B equipment list.
TER EQUIPMENT ITEM NO.: 122 Plant ID: T48-TE N009A,B,&D Temperature Element Located in the Torus Room Rosemount Model 10414601 Service: Torus Water Temperature CORRECTIVE ACTION: The temperature element will be replaced with a qualified PYC0 temperature element during the Unit 1, 1984 Refueling Outage.
A i 4 d
O TER EQUIPMENT ITEM NO.: 123 Plant ID: T48-TE N009C Temperature Element Located in the Torus Room Rosemount Model 104AGP-4 Service: Torus Water Temperature CORRECTIVE ACTION: The temperature element will be replaced with a qualified PYC0 temperature element during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 124 Plant ID: T47-TE N008 Temperature Element Located in the Containment Rosemount Model 10414591 Service: Ambient Containment Temperature CORRECTIVE ACTION: The temperature element will be replaced with a qualified PYC0 temperature element during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 124 Plant ID: T47-TE N005 Temperature Element Located in the Containment Rosemount Model 10414591 Service: Ambient Containment Temperature
(' CORRECTIVE ACTION: The temperature element will be replaced with a qualified PYC0 temperature element during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 125 Plant ID: B21-TS N010A,B.C.D Temperature Switch Located in the Pipe Chase Fenwall Model 17002-40 Service: Main Steam Line Leak Detector CORRECTIVE ACTION: The temperature switch will be replaced with a qualified Weed temperature element and a qualified General Electric trip unit as part of the Analog Transmitter Trip Syrtem (ATTS). ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.- 125 l Plant ID: B21-TS N011A,B,C,D 1
Temperature Switch Located in the Pipe Chase Fenwall Model 17002-40 Service: Main Steam Line Leak Detector CORRECTIVE ACTION: The temperature switch will be replaced with a qualified Weed temperature element and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage.
n x-
U TER EQUIPMENT ITEM No.: 125 Plant ID: B21-TS N012A,B.C.D Temperature Switch Located in the Pipe Chase Fenwall Model 17002-40 Service: Main Steam Line Leak Detector CORRECTIVE ACTION: The temperature switch will be replaced with a qualified Weed temperature element and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM No.: 125 Plant ID: B21-TS N013A,B,C,D Temperature Switch Located in the Pipe Chase Fenwall Model 17002-40 Service: Main Steam Line Leak Detector CORRECTIVE ACTION: The temperature switch will be replaced with a qualified Weed temperature element and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 126 i Plant ID: E51-TE N026B,D Temperature Element Located in the Northeast Corner Room l
l
'} PYC0 Model N145C3224P1 l Service: Steam Leak Detector CORRECTIVE ACTION: The temperatura element will be replaced with a qualified l Weed temperature element as part of the Analog Transmitter Trip System (ATTS).
ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage.
l TER EQUIPMENT ITEM NO.: 126 Plant ID: E41-TE NO30A,B Temperature Element Located in the HPCI Room PYC0 Model N145C3224P1 Service: Steam Leak Detector CORRECTIVE ACTION: The temperature element will be replaced with a qualified Weed temperature element as part of the Analog Transmitter Trip System (ATTS).
ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 126 Plant ID: E41-TE N046A,B Temperature Element Located in the Pipe Penetration Room PYC0 Model N145C3224P1 Service: Steam Leak Detector CORRECTIVE ACTION: The temperature element will be replaced with a qualified Weed temperature element as part of the Analog Transmitter Trip System (ATTS).
('~3
_,) ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage.
l l
l
b i /
'~'
TER EQUIPMENT ITEM NO.: 127 Plant ID: ESI-TE N025A,B,C,D Temperature Element Located in the Torus Room PYC0 Model N145C3224P1 Service: Steam Leak Detector CORRECTIVE ACTION: The temperature element will be replaced with a qualified Weed temperature element as part of the Analog Transmitter Trip System (ATTS).
ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 128 Plant ID: E51-TE N027A,B,c,D Temperature Element Located in the Reactor Building, Elev. 130' 0" PYC0 Model N145C3224P1 Service: Steam Leak Detector CORRECTIVE ACTION: The temperature element will be replaced with a qualified Weed temperature element as part of the Analog Transmitter Trip System (ATTS).
ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 128 Plant ID: G31-TE N016A,B,D,E Temperature Element Located in the RWCU Hx Room PYC0 Model N145C3224P1 Service: RWCU System Leak Detector CORRECTIVE ACTION: The temperature element will be replaced with a qualified Weed temperature element as part of the Analog Transmitter Trip System (ATTS).
ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 128 Plant ID: G31-TE N022A.D Temperature Element Located in the RWCU Hx Room PYC0 Model N145C3224P1 Service: RWCU System Leak Detector CORRECTIVE ACTION: The temperature element will be replaced with a qualified Weed temperature element as part of the Analog Transmitter Trip System (ATTS).
ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 128 Plant ID: G31-TE N022B,C,E,F Temperature Element Located in the RWCU Pump Room PYC0 Model N145C3224P1 Service: RWCU System Leak Detector CORRECTIVE ACTION: The temperature element will be replaced with a qualified Weed temperature element as part of the Analog Transmitter Trip System (ATTS).
ATTS will be installed prior to or during the Unit 1 1984 Refueling Outage.
O
[\
v TER EQUIPMENT ITEM NO.: 128 Flant ID: G31-TE N023A.D Temperature Element Located in the RWCU Hx Room PYC0 Model N145C3224P1 Service: RWCU System Leak Detector CORRECTIVE ACTION: The temperature element will be replaced with a qualified Weed temperature element as part of the Analog Transmitter Trip System (ATTS).
ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 128 Plant ID: G31-TE N023B,C E.F Temperature Element Located in the Reactor Building, Elev. 158' 0" PYC0 Model N145C3224P1 Service: RWCU System Leak Detector CORRECTIVE ACTION: The temperatura element will be replaced with a qualified Weed temperature element as part of the Analog Transmitter Trip System (ATTS).
ATTS will be installed prio.r to or during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 129 Plant ID: E51-TE N026A.C Temperature Element Located in the Southwest Corner Room PYC0 Model N145C3224P1 Service: Steam Leak Detection
[ }
CORRECTIVE ACTION: The temperature element will be replaced with a qualified i Weed temperature element as part of the Analog Transmitter Trip System (ATTS).
ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 129 i Plant ID: E51-TE N021A,B Temperature Element Located in the Southwest Corner Room PYC0 Model N145C3224P1 Service: Steam Leak Detection CORRECTIVE ACTION: The temperature element will be replaced with a qualified Weed temperature element as part of the Analog Transmitter Trip System (ATTS).
ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 129 Plant ID: E51-TE N022A,B Temperature Element Located in the Southwest Corner Room PYC0 Model N145C3224P1 Service: Steam Leak Detection CORRECTIVE ACTION: The temperature element will be replaced with a qualified Weed temperature element as part of the Analog Transmitter Trip System (ATTS).
ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage.
(v
k TER EQUIPMENT ITEM NO.: 129 Plant ID: E51-TE N023A,B Temperature Element Located in the Southwest Corner Room PYC0 Model N145C3224P1 Service: Steam Leak Detection CORRECTIVE ACTION: The temperature element will be replaced with a qualified Weed temperature element as part of the Analog Transmitter Trip System (ATTS).
ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 144 Plant ID: Instrument Cables Electrical Cables Located Outside the Drywell Manufacturer and Model Not Known Service: GE Panel Wiring CORRECTIVE ACTION: The existing wire will be replaced with qualified wire during installation of the Analog Transmitter Trip System, which is scheduled for completion during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 148
, Plant ID: N3-04 Electrical Cable, Instrument Located Outside the Drywell
' Boston Insulated Wire 4/C #16 AWG Service: Instrumentation CORRECTIVE ACTION: The cable will be replaced with qualified cable prior to or during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM No.: 154 Plant ID: H1-16 Electrical Cable, Instrument Located in the Reactor Building, Elev. 130' 0" Okonite Model 600V PVC Service: Instrumentation P33-P001A/B Only CORRECTIVE ACTION: The cable will be replaced with qualified cable prior to or during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 178 Plant ID: Ell-MOV F008 Motorized Valve Actuator Located in the Pipe Penetration Room i Limitorque Model SMB, DC Service, Class B Insulation Service: Shutdown Cooling Suction Isolation CORRECTIVE ACTION: The motor for this motor operated valve will be replaced with <
a qualified motor prior to or during the Unit 1, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.: 181 Plant ID: T46-DPT N005B,C D/P Transmitter Located in the Reactor Building, Elev. 130' 0" l Rosemeunt Model 1151DP3B22LMMB Service: Pressure Reactor Building to Atmosphere Pressure CORRECTIVF ACTION: The transmitter will be replaced with qualified Rosemount
- Type 1153 transmitter during the Unit 1, 1984 Refueling Outage.
i l
I t
1
_ .. . . - . _ . . _ . . . - _ _ _ _ _ . . . . . . _ . . . . _ _ . . . _ _ _ . _ , . . . _ . , _ , . . _ _ _ _ . _ . _ . _ . _ . . . . . . _ _ _ _ , . . _ _ . . ~ - , _ _ _ . , ,
l 8
The following equipment was not addressed in Franklin Research Center's Technical Evaluation Report. However, the equipment is part of Georgia Power Company's I. E. Bulletin 79-01B Open Item List.
Plant ID: G31-TE N0160,F Temperature Element Located in the RWCU Pump Room PYC0 Model N145C3224P1 Service: RWCU System Leak Detector CORRECTIVE ACTION: The temperature element will be replaced with a qualified Weed temperature element as part of the Analog Transmitter Trip System (ATTS).
ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage.
Plant ID: P52-PIS N021 Pressure Indicating Switch Located in the Reactor Building, Elev. 130' 0" Ashcroft Model 1377TA Service: Instrument Air Pressure CORRECTIVE ACTION: The switch will be replaced with a qualified Rosemount Type 1153 transmitter and a Foxboro trip card (located in the Main Control Room)
During the Unit 1, 1984 Refueling Outage.
Plant ID: E41-MOV F006
\]-
- Motorized Valve Actuator Located in the Torus Limitorque Model SMB, DC Service, Class B Insulation Service: HPCI Pump Discharge Isolation CORRECTIVE ACTION: The motor for this motcr operated valve will be replaced with a qualified motor prior to or during the Unit 1, 1984 Refueling Outage.
Plant ID: E41-MOV F007 Motorized Valve Actuator Located in the HPCI Room Limitorque Model SMB, DC Service, Class B Insulation with Stearns Brake Service: HPCI Pump Discharge Isolation CORRECTIVE ACTION: The motor for this rootor operated valve will be replaced with a qualified motor prior to or during the Unit 1, 1984 Refueling Outage.
Q
O The following equipment was not addressed in Franklin Research Center's Technical Evaluation Report. However, the equipment is part of Georgia Power Company'1i I. E. Bulletin 79-01B Open Item Equipment List. l Plant ID: B31-PS N018A,B Pressure Switch Located in the Reactor Building Elev. 130' 0" Barksdale Model B2T-M12SS Service: Recirculation Suction Pressure CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 1, 1984 Refueling Outage. Justification for continued operation was provided by Georgia Power Company in the I.E. Bulletin 79-01B status update dated January 3, 1983 and is still applicable.
O O
1 .
[
l I
i i
.i k
l l
l
! GEORGIA POWER COMPANY i
I EDWIN 1. HATCH NUCLEAR PLANT - UNIT 2 s^
J.
l DOCKET: 50-366 1 .
~ - -
w I
1- ,
c-I ENVIRONMENTAL QUALIFICATION OF CLASS 1E EQUIPMENT'r "-
MAY 20, 1983 RESPONSE TO NRC SAFETY EVALUATION REPORT:
,1
\
l AND RULE 10CFR50.49 s ,j
[ .
G REVISION 0, MAY 20, 1983 --
, \ i-i i
d s .
i i
., 1 I E
g l .-'
t
' s t
l l
, GEORGIA POWER COMPANY i EDWIN 1. HATCH NUCLEAR PLANT - UNIT 2
- DOCKET: 50-366 MAT 20, 1983 RESPONSE TO NRC SAFETY EVALUATION REPORT AND RULE 10CFR50.49
\
TABLE OF CONTENTS i'
. Section A - Introduction o
Section B'-- Environmentally Qualified Equipment List
> , Introduction s Equipment List -
(g# Sectiori C - Equipment Requiring Qualification Clarifications
.g Introduction
,, Clarification i
~
Section D - Open Item Equipment List Introduction Equipment List d ,' '
i>
T l
1 l
l l
't 4 mm~ - - ~ ~,- '-,-e-r, , w w w - --,,---.---,---w .,, ar-,-- ~
P i
SECTION A INTRODUCTION i,
SCOPE ,
J This submittal is provided by Georgia Power Company as the May 20, 1983 Response co(theNuclearRegulatoryCommission(NRC)SafetyEvaluationReport (SER) for
_ Environmental Qualification of Safety Related Electrical 5<1uipment (I.E.
~
,/,I Bulletin 79,-01hj and the Rulemaking 10 CFR 50.49 for Edwin I. Hatch Nuclear
. -Plant - Unit 2. 7 BACKGROUND On October 31, 1980,: Georgia Power Company submitted to the NRC an Environmental Qualification submittal in response to I. E. Bulletin 79-01B for Edwin I. Hatch Nuclear Plant - Unit 2. ,
On February 1, 1981 Georgia Power Company submitted revision 1 of the Environmental Qualification submittal in response to I. E. Bulletin 79-01B.
This revision included a response to Supplement B of the bulletin regarding TMI Action Plan Equipment and Equipment required to achieve to I. E. Bulletin,79-01B. .
O On February 17, L981, Georgia Power Company submitted revision 2 of the Environmental Qualification submittal in response to I. E. Bulletin 79-01B.
Based on review of Georgia Power Company's submittals conducted by. Franklin Research; Center (FRC), the NRC issued a Safety Evaluation Report '(SER) on June 16, 1981.
l Georgia Power Company provided a response to the SER as part of revision 3 of I
the Environmental Oualification submittal to I. E. Bulletin 79-01B issued on September 14, 1981. ,
i On February 10, 1982, Georgia Power Company provided the NRC with additional qualification information. The NRC requested this information in order for FRC to complete the review of. the Environmental Qualification submittel provided by Georgia Power Compiny. ,
The Safety Evaluation Report (SER) together with a Technical Evaluation Report i l
(TER), was transmitted to Georgia Power Company by letter, dated March 31, 1983, l from Mr. John F. Stolz, CFief Operating Reactors Branch No. 4, Division of j
-/ Licensing to Mr. J. T. Br:.kham, Jr., Vice President Nuclear-Generation Georgia f . Poser. Company.
, 4
' E lOn May 6,1983. Georgia Power Company submitted the required Thirty (30) Day
- Response to the NRC Safety Evaluation Report.
g a g
, \, '
l
< l
SUBMITTAL This submittal is comprised of four (4) major sections; Section A -
Introduction Section B - Environmentally Qualified Equipment List, Section C -
j Equipment Requiring Qualification Clarifications, and Section D - Open Item Equipment List. [
Section B of this submittal provides a list of safety related equipment which Georgia Power Company considers environmentally qualified.
Section C of this submittal provides clarifications and additional information j required to address the NRC discrepancies listed for eq2ipment in NRC :
Qualification Category II.c. Clarifications for equipment in NRC Qualification
- Categories I.b. II.s. and II.b were provided in the Thirty (30) Day Recponse to the NRC Safety Evaluation Report.
]
i Section D of this submittal provides a list of safety related equipment which Georgia Power Company considers to have open items concerning Environmental ,
! Qualification. A Corrective Action is provided for each equipment item included i in this list.
Justifications for Continued Operation for the Equipment having open items concerning qualification were submitted in the Thirty (30) Day Response to the Safety Evaluation Report or were included in previous I. E. Bulletin 79-01B submittals and reaffirmed in the Thirty (30) Day Response.
0 "'scussto"s co"c'*"'"o autt"^x'"o to cra so
! Georgia Power Company's previous I.E. Bulletin 79-01B submittals have been
) reviewed against the requirements of paragraphs (a) and (b) of 10 CFR 5G.49 and i it is concluded that Georgia Power Company's program for Qualifying Electrical Equipment includes all harsh environment equipment (non-safety related as well as safety related equipment) that is relied upon to remain functional during and following a High Energy Line Break (HELB) or Loss of Coolant Accident (LOCA).
! A syscematic review of the control and power circuit for each component which is l associated with equipment covered in I.E. Bulletin 79-01B was completed. Each circuit was reviewed to assure that the failure of any component within the i circuit, which is located in a harsh environment, could w
- nrevent the I.E.
Bulletin 79-01B component from serving its safety relate r '* ion.
j Post-accident monitoring Equipment was included in Georgia Power Company's I.E.
l Bulletin 79-018 submittals to the extent thac it was identified using the
- methodology described above. Georgia Power Company is currently negotiating a schedule with the NRC staff for responding to Supplement 1 to NUREG-0737 (Reference Generic Letter 82-33). A portion of the response to the supplement will compare Hatch Nuclear Plant - Unit I with the " requirements" of Kegulatory i
Guide 1.97, Revision 2 and will justify any exceptions to the Regulatory Guide which are taken. In those cases where deviations cannot be justified, the 1 Regulatory Guide " requirements" will be met. If the instrument is located in a harsh environment and installed prior to May 23, 1980, qualification of the instrument will be evaluated against the D0R Guidelines. If the instrument was installed after May 23, 1980, qualification will be evaluated against i NUREG-0588, Category I or the 10CFR50.48 rule as applicable.
t
, i SECTION B ENVIRONMENTALLY QUALIFIED EQUIPMENT LIST INTRODUCTION This section provides, per the requirements of 10CFR 50.49. Paragraph'(g), a list of electrical equipmeni. important to safety, which Georgia Power Company considers environmentally qualified.
The environmentally qualified equipment is identified by the TER Equipment Item Number (if applicable) and associated Plant Identification Number, followed by the Equipment Location, Equipment Description and the Equipment Service.
O l
i O '
l l
e- v -- - -m-- --rm--- --e w -r- e 9 y--e- c -
S --
-w-e y-- - - , we - - - - -
->-w--- y-mwe --- - -wv-r- ----e------g
1 i
i i
TABLE B-1 ENVIRONMENTALLY QUALIFIED EQUIPMENT LIST ;
TER EQUIPMENT ITEM NO: 1 Plant ID: 2E11-MOV F049 Motorized Valve Actuator Located in the Torus Room Limitorque SMB, DC Service, Class B Insulation Service: Reactor Water Discharge Isolation Valve TER EQUIPMENT ITEM No: 2 Plant ID: 2E11-MOV F024A,B Motorized Valve Actuator Located in the Torus Room
.; Limitorque Model SMB, AC Service, Class RH Insulation Service: RHR Testline Valve i TER EQUIPMENT ITEM NO: 3
- Plant ID
- 2 Ell-MOV F023
- Motorized Valve Actuator Located in the Reactor Building, Elev. 185'0" j
Limitorque Model SMB, DC Service, Class H Insulation ,
l Service: Vessel Head Spray Isolation Valve TER EQUIPMENT ITEM No: 4 I
Plant ID: 2E41-MOV F003 Motorized Valve Actuator Located in the Pipe Penetration Room Limitorque Model SMB, DC Service, Class H Insulation -
Service: Steam Supply Outboard Isolation Valve TER EQUIPMENT ITEM NO: 9 Plant ID: 2G31-MOV F004 Motorized Valve Actuator Located in the Reactor Building, Elev. 158'0" Limitorque Model SMB, DC Service, Class H Insulation Service: Downstream Isolation Valve TER EQUIPMENT ITEM NO: 12
, Plant ID: 2E11-MOV F017A.B I Motorized Valve Actuator Located in the Pipe Penetration Room
- Limitorque Model SMB, AC Service, Class RH Insulation
. Service: LPCI Discharge Valve l TER EQUIPMENT ITEM NO: 13 Plant ID: 2 Ell-MOV F009 Motorized Valve Actuator Located in the Containment Limitorque Model SMB (SB, Size 2), AC Service, Class RH Insulation Service: Shutdown Cooling Isolation Valve TER EQUIPMENT ITEM NO: 13 l
, Plant ID: 2E41-MOV F002 '
Motorized Valve Actuator Located in the Containment Limitorque Model SMB (SB, Size 2), AC Service, Class RH Insulation O Service: Steam Line Isolation I
l
-ur -m v.7 ww e y e p .-e- ----.y- 7 --m-, . , --w-.g,m- ,,,p- m.. A.,.m,p-_,e,*-e. . - . , - .-w ,-, , ,w , , yw ,,w-.,-. w-g,,, p. ,,,,,wg.--we.--- w,-----w-- --r,,,,-, - - . ,-- , - - -, ,w,
l l
TER EQUIPMENT ITEM NO: 14 Plant ID: 2B21-MOV F019 Motorized Valve Actuator Located in the Pipe Chase Limitorque Model SMB, DC Service, Class H Insulation Service: Main Steam Line Isolation TER EQUIPMENT ITEM NO: 14 Plant ID: 2E51-MOV F008 Motorized Valve Actuator Located in the Pipe Chase Limitorque Model SMB, DC Service, Class H Insulation Service: Steam Supply Outboard Isolation Valve TER EQUIPMENT ITEM No: 15 Plant ID: 2E41-MOV F111 Motorized Valve Actuator Located in the Torus Room Limitorque Model SMB, AC Service, Class B Insulation Service: Vacuum Breaker Isolation TER EQUIPMENT ITEM NO: 15 Plant ID: 2E41-MOV F104 Motorized Valve Actuator Located in the Torus Room Limitorque Model SMB, AC Service, Class B Insulation Service: Vacuum Breaker Isolation TER EQUIPMENT ITEM NO: 17 ,
Plant ID: 2E41-MOV F001 Motorized Valve Actuator Located in the HPCI Room Limitorque Model SMB, DC Service, Class B Insulation Service: System Isolation Valve TER EQUIPMENT ITEM NO: 17 Plant ID: 2E41-MOV F041 Motorized Valve Actuator Located in the HPCI Room l Limitorque Model SMB, DC Service, Class B Insulation l Service: Pump Suction from Suppression Pool TER EQUIPMENT ITEM NO: 17 Plant ID: 2E41-MOV F059 l Motorized Valve Actuator Located in the HPCI Room l Limitorque Model SMB, DC Service, Class B Insulation l Service: Booster Pump Discharge to Barometric Condenser l TER EQUIPMENT ITEM NO: 17 Plant ID: 2E41-MOV F007 Motorized Valve Actuator Located in the HPCI Room Limitorque Model SMB, DC Service, Class B Insulation l Service: HPCI Pump Outboard Discharge Valve lC
E O
TER EQUIPMENT ITEM NO: 18 Plant ID: 2 Ell-MOV F011A B Motorized Valve Actuator Located in the Northeast and Southeast Corner Rooms Limitorque Model SMB, AC Service, Class B Insulation Service: RHR HX A&B to Core Spray TER EQUIPMENT ITEM NO: 18 Plant ID: 2 Ell-MJV F026A,B Motorized Valfe Actuator Located in the Northeast and Southeast Corner Rooms Limitorque Model SMB, AC Service, C1t.ss B Insulation Service: RHR HX A&B to RCIC TER EQUIPMENT ITEM NO: 18 Plant ID: 2 Ell-MOV F003B Motorized Valve Actuator Located in the Northeast and Southeast Corner Rooms Limitorque Model SMB, AC Service, Class B Insulation Service: HX Discharge TER EQUIPMENT ITEM NO: 18 Plant ID: 2 Ell-MOV F048A B Motorized Valve Actuator Located in the Northeast and Southeast Corner Rooms Limitorque Model SMB, AC Service, Class B Insulation Service: RHR HX A&B Bypass Valve TER EQUIPMENT ITEM NO: 18 Plant ID: 2 Ell-MOV F004A,B.C.D Motorized Valve Actuator Located in the Northeast and Southeast Corner Rooms Linitorque Model SM3, AC Service, Class B Insulation Service: RHR Pump C002A,B C,D Suction Valve TER EQUIPMENT ITEM NO: 18 Plant ID: 2 Ell-MOV F006B Motorized Valve Actuator Located in the Northeast and Southeast Corner Rooms Limitorque Model SMB, AC Service, Class RH Insulation Service: Shut Down Cooling Suction Isolation Valve TER EQUIPMENT ITEM NO: 18 Plant ID: 2 Ell-MOV F007A,B Motorized Valve Actuator Located in the Northeast and Southeast Corner Rooms Limitorque Model SMB, AC Service, Class B Insulation Service: Fump C002A,B,C,D Minimum Flow Bypass j TER EQUIPMENT ITEM NO: 18 Plant ID: 2 Ell-MOV F006A C.D
! Motorized Valve Actuator Located in the Nertheast and Southeast Corner Rooms Limitorque Model SMB, AC Service, Class B Insulation Service: Shut Down Cool Suction Isolation Valve
()
I
{
l l
_ _ - _ _ -- - . . . .- -. . . -. . _ _ . . ~ . -- .
s TER EQUIPMENT ITEM NO: 18 Plant ID: 2E11-MOV F047A,B Motorized Valve Actuator Located in the Northeast and Southeast Corner Rooms
, Limitorque Model SMB, AC Service, Class B Insulatio-Service: RHR RX A&B to Inlet Valve TER EQUIPMENT ITEM NO: 18 Plant ID: 2E21-MOV F001A,B
, Motorized Valve Actuator Located in the Northeast and Southeast Corner Rooms
! Limitorque Model SMB, AC Service, Class B Insulation
- Service
- Pump C001A & B Valve TER EQUIPMENT ITEM NO: 18 Plant ID: 2E21-MOV F015A B Motorized Valve Actuator Located in the Northeast and Southeast Corner Rooms Limitorque Model SMB, AC Service, Class B Insulation Service: Test Bypass Valve TER EQUIPMENT ITEM NO: 18 Plant ID: 2E21-MOV F031A,B Motorized Valve Actuator Located in the Northeast and Southeast Corner Rooms Limitorque Model SMB, AC Service, Class B Insulation Service: Minimum Flow Bypass Valve TER EQUIPMENT ITEM NO: 18 Plant ID: 2E11-MOV F104A,B Motorized Valve Actuator Located in the Northeast and Southeast Corner Rooms Limitorque Model SMB, AC Service, Class B Insulation Service: Residual Heat Removal HX A&B Ventilation TER EQUIPMENT ITEM NO: 18 Plant ID: 2E11-MOV F103A,B Motorized Valve Actuator Located in the Northeast and Southeast Corner Rooms Limitorque Model SMB, AC Service, Class B Insulation Service: Residual Heat Removal HK A&B Ventilation TER EQUIPMENT ITEM NO: 19 Plant ID: 2E11-MOV F091A,B Motorized Valve Actuator Located in the Torus Room Limitorque Model SMB, AC Service, Class RH Insulation Service: HPCI Discharge to HX A & HX B l~ TER EQUIPMENT ITEM NO: 23 Plant ID: 2E11-MOV F040 Motorized Valve Actuator Located in the Torus Room Limitorque Model SMB, AC Service, Class B Insulation Service: R. W. Discharge Isolation Valve L
_ _ _ _ ~- _ ____
E
! O TER EQUIPMENT ITEM NO: 23 Plant ID: 2E11-MOV F119A,B Motorized Valve Actuator Located in the Torus Room i Limitorque Model SMB, AC Servica, Class B Insulation Service: RHR HX Bypass TER EQUIPMENT ITEM NO: 23 i
Plant ID: 2 Ell-MOV F010 Motorized Valve Actuator Located in the Torus Room Limitorque Model SMB, AC Service, Class B Insulation Service: Residual Heat Removal System Cross-Tie TER EQUIPMENT ITEM NO: 24 Plant ID: 2E11-MOV F027B Motor'eed Valve Actuator Located in the Torus Room Limitorque Model SMB, AC Service, Class B Insulation Service: Suppression Pool Spray Valve TER EQUIPMENT ITEM NO: 24 Plant ID: 2Eli-MOV F073A,B Motorized Valve Actuator Located in the Torus Room 1 Limitorque Model SMB, AC Service, Class B Insulation Service: RHR Service Water Pump Discharge Valves l TER EQUIPMENT ITEM No: 24 Plant ID: 2E11-MOV F075A Motorized Valve Actuator Located in the Torus Room Limitorque Model SMB, AC Service, Class B Insulation Service: RHR Water Pump Discharge Valve i TER EQUIPMENT ITEM NO: 24 Plant ID: 2E32-MOV F003,B K.F.P Motorized Valve Actuator Located in the Torus Room Limitorque Model SMB, AC Service, Class B Insulation Service: Main Steam Line Leakage Control Isolation Valves TER EQUIPMENT ITEM NO: 26 Plant'ID: 2E51-MOV F007 Motorized Valve Actuator Located in the Containment Limitot:que Model SMB, AC Service, Class RH Insulation Servir.e: RCIC Steam Inboard Isolation Valve TER EQUIPMENT ITEM NA 27 Plant ID: 2G31-MOV F001 Motorized Valve Actuator Located in the Containment Limitorque Model ShB, AC Service, Class RH Insulation Service: Upstream Isolation Valve O
l
> l 1
O TER EQUIPMENT ITEM No: 28 Plant ID: 2B21-MOV F016 Motorized Valve Actuator Located in the Containment
. Limitorque Model SMB, AC Service, Class RH Insulation Service: Main Steam Line Isolation TER EQUIPMENT ITEM No: 29 Plant ID: 2T49-MOV F002A B
, Motorized Valve Actuator Located in the Reactor Building, Elev. 185'0" Limitorque Model SMB, AC Service, Class B Insulation Service: Cas from DW Outboard Isolation Valve TER EQUIPMENT ITEM NO: 29 Plant ID: 2T49-MOV F001A,B Motorized Valve Actuator Located in the Reactor Building, Elev. 185'0" Linitorque Model SMB, AC Service, Class B Insulation Service: Cas from DW Inboard Isolation Valve TER EQUIPMENT ITEM NO: 31 Plant ID: 2E11-MOV F068A,B Motorized Valve Actuator Located in the Northeast and Southeast Corner Rooms Limitorque Model SMB, AC Service, Class B Insulation Service: RHR Service Water Flow Control O TER EQUIPMENT ITEM NO: 31 1 Plant ID: 2T49-MOV F006A B Motorized Valve Actuator Located in the Northeast and Southeast Corner Rooms Limitorque Model SMB, AC Service, Class B Insulation Service: Feedwater from RHR to Cooler Isolation Valve TER EQUIPMENT ITEM NO: 33 Plant ID: 2E32-MOV F001B F,K.P Motorized Valve Actuater Located in the Pipe Chase Limitorque Model SMB, AC Service, Class RH Insulation Service: Main Steam Line Leakage Control Isolation Valve TER EQUIPMENT ITEM NO: 34 Plant ID: 2P42-MOV F052 -
Motorized Valve Actuator Located in the Torus Room Limitorque Model SMB, AC Service, Class B Insulation Service: System Inlet Containment Isolation TER EQUIPMENT ITEM NO: 34 Plant ID: 2P42-MOV F051 Motorized Valve Actuator Located in the Torus Room Limitorque Model SMB, AC Service, Class B Insulation Service: System Inlet Containment Isolation O
i
O TER EQUIPMENT ITEM NO: 35 Plant ID: 2T49-MOV F005A,B Hotorized Valve Actuator Located in the Torus Room Limitorque Model SMB, AC Service, Class B Insulation Service: Gas & Water Return to Torus Isolation Valve TER EQUIPMENT ITEM No: 35 Plant ID: 2T49-MOV F004A B Motorized Valve Actuator Located in the Torus Room Limitorque Model SMB, AC Service, Class B Insulation Service: Gas & Water Return to Torus Isolation Valve TER EQUIPMENT ITEM NO: 36 Plant ID: 2P64-MOV F047 Motorized Valve Actuator Located in the Reactor Building, Elev. 130'0" Limitorque Model SMB, AC Service, Class B Insulation i Service: Primary Containment Isolation TER EQUIPMENT ITEM NO: 36 Plant ID: 2P64-MOV F045 Motorized Valve Actuator Located in the Reactor Building Elev. 130'0" Limitorque Model SMB, AC Service, Class B Insulation Service: Primary Containment Isolation O TER EQUIPMENT ITEM NO: 37 l
Plant ID: 2E51-MOV F104 Motorized Valve Actuator Located in the Torus Room Limitorque Model SMB, AC Service, Class RH Insulation Service: Exhaust to Torus Penetration TER EQUIPMENT ITEM NO: 38 Plant ID: 2T48-A0V F335A,B Solenoid Valve Located in the Reactor Building, Elev. 185'0" ASCO Model NP8320A186E l Service: Containment Isolation Valve l
l TER EQUIPMENT ITEM NO: 38 l Plant ID: 2T48-A0V F334A,B Solenoid Valve Located in the Reactor Building, Elev. 185'0" ASCO Model NP8320A186E Service: Containment Isolation Valve TER EQUIPMENT ITEM NO: 38 Plant ID: 2T48-A0V F333A,B Solenoid Valve Located in the Torus Room ASCO Model NP8320A186E Service: Containment Isolation Valve O
s I _
. . - ~. - _ .-
1 O TER EQUIPMENT ITEM NO: 38 Plant ID: 2T48-A0V F332A,B Solenoid Valve Located in the Torus Room ASCO Model NP8320A186E
- Service: Containment Isolation Valve TER EQUIPMENT ITEM No: 38 Plant ID: 2T48-A0V F327 Solenoid Valve Located in the Torus Room ASCO Model NP206-380-3F Service: Containment Isolation Valve TER EOUIPMENT ITEM NO: 38 Plant ID: 2T48-A0V F325 Solenoid Valve Located in the Torus Room ASCO Model NP206-380-3F Service: Containment Isolation Valve TER EQUIPMENT ITEM No: 38 Plant ID: 2T48-A0V F322 Solenoid Valve Located in the Torus Room ASCO Model NP206-380-3F s Service: Containment Isolation Valve TER EQUIPMENT ITEM No: 38 ,
Plar.t ID: 2T48-A0V F321 Solenoid Valve Located in the Torus Room ASCO Model NP206-380-3F Service: Containment Isolation Valve TER EQUIPMENT ITEM NO: 38 Plant ID: 2T48-A0V F116 Solenoid Valve Located in the Torus Room ASCO Model NP206-380-3F Service: Containment Isolation Valve
. TER EQUIPMENT ITEM NO: 38 Plant ID: 2T48-A0V F115 Solenoid Valve Located in the Torus Room ASCO Model NP206-380-3F Service: Containment Isolation Valve TER EQUIPMENT ITEM No: 38 Plant ID: 2T48-A0V Fil4 Solenoid Valve Located in the Torus Room ASCO Model NP206-380-3F Service: Containment Isolation Valve gs !
w.-
i
O TER EQUIPMENT ITEM NO: 38 Plant ID: 2T48-A0V F113 Solenoid Valve Located in the Torus Room ASCO Model NP206-380-3F Service: Containment Isolation Valve TER EQUIPMENT ITEM NO: 38 Plant ID: 2P70-A0V F005 Solenoid Valve Located in the Torus Room ASCO Model NP206-380-3F Service: Containment Isolation Valve TER EQUIPMENT ITEM NO: 38 Plant ID: 2P70-A0V F004 Solenoid Valve Located in the Reactor Building, Elev. 158'0" ASCO Model NP206-381-3F Service: Containment Isolation Valve TER EQUIPMENT ITEM NO: 38 Plant ID: 2P70-A0V F001A Solenoid Valve Located in the Reactor Building, Elev. 158'0" ASCO Model NP206-381-3F s Service: Drywell Nitrogen Make-up
\
s,,, TER EQUIPMENT ITEM No: 39 -
Plant ID: 2T48-A0V F340 Solenoid Valve Located in the Reactor Building, Elev. 185'0" ASCO Model NP8320A186E Service: Containment Isolation valve TER EOUIPMENT ITEM NO: 39 Plant ID: 2T48-A0V F341 Solenoid Valve Located in the Torus Room ASCO Model NP8320A186E Service: Containment Isolation Valve TER EQUIPMENT ITEM No: 39 Plant ID: 2T48-A0V F103 Solenoid Valve Located in the Torus Room ASCO Model NP831654E Service: Drywell Torus Purge TER EQUIPMENT ITEM No: 39 Plant ID: 2T48-A0V F338 Solenoid Valve Located in the Torus Room ASCO Model NP8320A186E Service: Containment Isolation Valve V'
(
TER EQUIPMENT ITEM NO: 39 Plant ID: 2T48-A0V F339 Solenoid Valve Located in the Torus Room ASCO Model NP8320A186E l Service: Containment Isolation Valve TER EQUIPMENT ITEM NO: 39 Plant ID: 2T48-A0V Fil8A,B Solenoid Valve Located in the Torus Room ASCO Model NP206-380-3F Service: Containment Isolation Valve TER EQUIPMENT ITEM NO: 39 Plant ID: 2T48-A0V F104 Solenoid Valve Located in the Torus Room ASCO Model HP206-380-3F Service: Containment Isolation Valve TER EQUIPMENT ITEM NO: 39 Plant ID: 2P70-A0V F003 Solenoid Valve Located in the Reactor Building, Elev. 158'0" ASCO Model NP206-380-3F Service: Containment Isolation Valve s
TER EQUIPMENT ITEM No: 39 -
Plant ID: 2P70-A0V F002 Solenoid Valve Located in the Reactor Building, Elev. 158'0" ASCO Model NP206-380-3F Service: Containment Isolation Valve TER EQUIPMENT ITEM NO: 39 Plant ID: 2Dll-A0V F052 Solenoid Valve Located in the Reactor Building, Elev. 130'0" ASCO Model NP206-380-3F Service: Fission Products Sample Isolation Valve TER EQUIPMENT ITEM No: 39 Plant ID: 2D11-AOV F051 Solenoid Valve Located in the Pipe Penetration Room ASCO Model NP206-381-3F Service: Fission ?roducts Sample Isolation Valve TER EQUIPMENT ITEM NO: 39 Plant ID: 2D11-AOV F050 Solenoid Valve Located in the Reactor Building, Elev. 130'0" ASCO Model NP206-381-3F Service: Fission Products Sample Isolation Valve s
v
TER EQUIPMENT ITEM NO: 39 Plant ID: 2Dll-A0V F053 Solenoid Valve Located in the Pipe Penetration Room ASCO Model NP206-380-3F Service: Fission Products Sample Isolation Valve TER EQUIPMENT ITEM NO: 40 Plant ID: 2 Ell-A0V F065A,B C.D Solenoid Valve Located in the Torus Room ASCO Model NP831664E Service: RHR Pump C002A,B,C,D Suction Valve TER EQUIPMENT ITEM NO: 41 Plant ID: 2B31-A0V F019 Solenoid Valve Located in the Containment ASCO Model NP8320A186E Service: Sample Line TER EQUIPMENT ITEM NO: 42 Plant ID: 2 Ell-A0V F051A,B Solenoid Valve Located in the Northeast and Southeast Corner Rooms ASCO Model NP206-380-3F Service: Residual Heat Removal HX A&B in from HPCI O TER EQUIPMENT ITEM NO: 42 Plant ID: 2E11-A0V F053A,B Solenoid Valve Located in the Northeast and Southeast Corner Rooms ASCO Model NP206-380-3F Service: Residual Heat Removal HX A&B Discharge to RCIC TER EQUIPMENT ITEM No: 43 Plant ID: 2P41-A0V F040A,B Solenoid Valve Located in the RCIC (NW) Corner Room ASCO Model NP206-380-3F Service: RCIC Room Cooler Supply i TER EQUIPMENT ITEM NO: 44 Plant ID: 2T46-A0V F001B Solenoid Valve Located in the Reactor Building, Elev. 185'0" ASCO Model NP8320A188E i Service: Inlet Damper to Filter B TER EQUIPMENT ITEM NO: 45 Plant ID: 2B21-A0V F028A,B,C,D Solenoid Valve Located in the Pipe Chase ASCO Model NP8320A183V Service: Main Steam Line Isolation O
O TER EQUIPMENT ITEM NO: 46 Plant ID: 2B21-A0V F022A,B,C D Solenoid Valve Located in the Containment ASCO Model NP8320A183V Service: Main Steam Line Isolation TER EQUIPMENT ITEM NO: 47 Plant ID: 2T41-A0V F003B Solenoid Valve Located in the Reactor Building Elev. 203'0" ASCO Model NP8321A2E Service: Out. Refueling Floor Fans 2A, 2B TER EQUIPMENT ITEM NO: 47 Plant ID: 2T41-A0V F011B Solenoid Valve Located in the Reactor Building Elev. 185'0" ASCO Model NP8321A2E Service: Reactor Zone Support Fan Isolation Damper TER EQUIPMENT ITEM NO: 47 Plant ID: 2T41-A0V F023A Solenoid Valve Located in the Reactor Building, Elev. 203'0" ASCO Model NP8321A2E
- N Service: Ref. Floor Exhaust Isolation Damper Rx Bldg. Vent System
's s TER EQUIPMENT ITEM NO: 48 Plant ID: 2Cll-SV D117 Solenoid Valve Located in the Reactor Building, Elev. 130'0" ASCO Model HVA-90-405 Service: SCRAM Pilot Valve TER EOUIPMENT ITEM NO: 48 Plant ID: 2Cll-SV Dll8 Solenoid Valve Located in the Peactor Building, Elev. 130'0" ASCO Model HVA-90-405 Servic: SCRAM Pilot Valve TER EQUIPMENT ITEM NO: 48 Plant ID: 2C11-SV F009 Solenoid Valve Located in the Reactor Building, Elev. 130'0" ASCO Model NP8323A22E Service: SCRAM Volume Drain Pilot Valve TER EQUIPMENT ITEM NO: 49
- Plant ID
- 2T48-A0V F307 Solenoid Valve Located in the Torus Room ASCO Model NP8316A74E Service: Inlet Valve to Drywell h
i i
TER EQUIPMENT ITEM NO: 49 Plant ID: 2T48-A0V F308 Solenoid Valve Located in the Torus Room ASCO Model NP8316A74E Service: Drywell Purge Air Inlet TER EQUIPMENT ITEM NO: 49 Plant ID: 2T48-A0V F309 Solenoid Valve Located in the Torus Room ASCO Model NP8316A74E Service: Torus Purge Air Inlet TER EQUIPMENT ITEM NO: 49 Plant ID: 2T48-A0V F310 Solenoid Valve Located in the Torus Room ASCO Model NP8316A74E
- Service
- Torus Pressure Equalizer Valve TER EQUIPMENT ITEM NO: 49 Plant ID: 2T48-A0V F311 Solenoid Valve Located in the Torus Room ASCO Model NP8316A74E Service: Torus Pressure Equalizer Valve TER EQUIPMENT ITEM NO: 49 Plant ID: 2T48-A0V F318 Solenoid Valve Located in the Torus Room ASCO Model NP8316A74E Service: Outlet Valve from Torus TER EQUIPMENT ITEM NO: 49 Plant ID: 2T48-A0V F319 Solenoid Valve Located in the Reactor Building, Elev. 185'0" ASCO Model NP8316A74E Service: Outlet Valve from Drywell TER EQUIPMENT ITEM NO: 49 Plant ID: 2T48-A0V F320 Solenoid Valve Located in the Reactor Building Elev. 185'0" ASCO Model NP8316A74E Service: Outlet Valve from Drywell TER EQUIPMENT ITEM NO: 49 Plant ID: 2T48-A0V F324 Solenoid Valve Located in the Torus Room ASCO Model NP8316A74E Service: Torus Purge Air Inlet
~-)
-,.w,- - - , - r-, - - - - , ,r ,- -- , , , , - , , , - -
m
{>
x-TER EQUIPMENT ITEM NO: 49 Plant ID: 2T48-A0V F326 Solenoid Valve Located in the Torus Room ASCO Model NP8316A74E Service: batlet Valve from Torus TER EQUIPMENT ITEM NO: 50 Plant ID: 2T48-A0V F211 Solenoid Valve Located in the Torus Room ASCO Model NP831654E Service: Drywell Torus DP System TER EQUIPMENT ITEM NO: 50 Plant ID: 2T48-A0V F209 Solenoid Valve Located in the Pipe Penetration Room ASCO Model NP831654E Service: Drywell Torus DP System TER EQUIPMENT ITEM No: 50 Plant ID: 2T48-A0V F210 Solenoid Valve Located in the Pipe Penetration Room ASCO Model NP831654E s Service: Drywell Torus DP System C- TER EQUIPMENT ITEM NO: 50 '
Plant ID: 2T48-A0V F212 Solenoid Valve Located in the Torus Room ASCO Model NP831654E Service: Drywell Torus DP System TER EQUIPMENT ITEM NO: 51 Plant ID: 2E21-A0V F019A,B-Solenoid Valve Located in the Torus Room ASCO Model NP8321A2E Service: Suppression Chamber Isolation Valve TER EQUIPMENT ITEM No: 51 Plant ID: 2E41-A0V F051 Solenoid Valve Located in the Torus Room ASCO Model NP8321A2E Service: Suppression Pool Suction Isolation Valve TER ?QUIPMENT ITEM NO: 51 Plant ID: 2E51-A0V F003 Solenoid Valve Located in the Torus Room ASCO Model NP8321A2E Service: Suppression Pool Suction Isolation Valve J
)
TER EQUIPMENT ITEM No: 52
- Plant ID
- 2G51-AOV F011 Solenoid Valve Located in the Torus Room ASCO Model NP206-380-3F Service: Torus Water Cleanup Isolation Valve TER EQUIPMENT ITEM No: 52 Plant ID: 2G51-A0V F013 Solenoid Valve Located in the Northeast and Southeast Corner Rooms ASCO Model NP206-380-3F Service: Torus Water Cleanup Isolation Valve TER EQUIPMENT ITEM NO: 52 Plant ID: 2G51-A0V F012
- Solenoid Valve Located in the Torus Room ASCO Model NP206-380-3F Service
- Torus Water Cleanup Isolation Valve TER EQUIPMENT ITEM No: 53 Plant ID: 2G11-A0V F020 Solenoid Valve Located in the Torus Room ASCO Model NP831654E Service: Drywell Equipment Drain Isolation Valve TER EQUIPMENT ITEM NO: 53 '
l Plant ID: 2Gil-A0V F019 Solenoid Valve Located in the Torus Room ASCO Model NP831654E Service: Drywell Equipment Drain Isolation Valve TER EQUIPMENT ITEM NO: 53-Plant ID: 2Gil-A0V F004 Solenoid Valve Located in the Torus Room
( ASCO Model NP831654E Service: Drywell Floor Drain Pump Isolation Valve l
l TER EQUIPMENT ITEM NO: 53 l Plant ID: 2Gil-A0V F003 Solenoid Valve Located in the Torus Room j ASCO Mcdel NP831654E Service: Drywell Floor Drain Pump Isolation Valve l
TER EQUIPMENT ITEM NO: 54 Plant ID: 2B21-A0V F077A,B Solenoid Valve Located in the Pipe Chase ASCO Model NP8323A37E Service: Feed Water Check Valve
\
TER EQUIPMENT ITEM No: 54 Plant ID: 2B21-A0V F076A,B Solenoid Valve Located in the Pipe Chase ASCO Model NP8323A37E Service: Feed Water Check Valvc TER EQUIPMENT ITEM NO: 55 Plant ID: 2P41-A0V F066 Solenoid Valve Located in the Torus Room ASCO Model NP8320A188E Service: Plant Service Water Inlet Div. 1 TER EQUIPMENT ITEM NO: 55 Plant ID: 2P41-A0V F067 Solenoid Valve Located in the Torus Room ASCO Model NP8320A188E Service: Plant Service Water Inlet Div. 2 TER EQUIPMENT ITEM No: 56 Plant ID: 2T48-SV F380 Solenoid Valve Located in the Torus Room ASCO Model NP8320A185E
}
N--
Service: Solenoid Valve for Sensing Line Isolation Valve 2T48-F364B TER EQUIPMENT ITEM No: 56 Plant ID: 2T48-SV F379 Solenoid Valve Located in the Torus Room ASCO Model NP8320A185E
- Service
- Solenoid Valve for Sensing Line Isolation Valve 2T48-F364B TER EQUIPMENT ITEM NO: 56 Plant ID: 2T48-SV F378 Solenoid Valve Located in the Torus Room
- ASCO Model NP8320A185E
! Service: Solenoid Valve for Sensing Line Isolation Valve 2T48-F364A 1
l TER EQUIPMENT ITEM NO: 56 l Plant ID: 2T48-SV F377 Solenoid Valve Located in the Torus Room ASCO Model NP8320A185E I
Service: Solenoid Valve for Sensing Line Isolation Valve 2T48-F304A s
s-~m U TER EQUIPMENT ITEM No: 56 Plant ID: 2T48-SV F372 Solenoid Valve Located in the Torus Room ASCO Model NP8320A185E Service: Solenoid Valve for Sensing Line Isolation Valve 2T48-F362B TER EQUIPMENT ITEM NO: 56 Plant ID: 2T48-SV F371 Solenoid Valve Located in the Torus Room ASCO Model NP8320A185E Service: Solenoid Valve for Sensing Line Isolation Valve 2T48-F362B TER EQUIPMENT ITEM NO: 56 Plant ID: 2T48-SV F370 Solenoid Valve Located in the Torus Room ASCO Model NP8320A185E Service: Solenoid Valve for Sensing Line Isolation Valve 2T48-F362A TER EQUIPMENT ITEM No: 56 Plant ID: 2T48-SV F369 Solenoid Valve Located in the Torus Room ASCO Model NP8320A185E Service: Solenoid Valve for Sensing Line Isolation Valve 2T48-F362A
( _, ) TER EQUIPMENT ITEM NO: 56 ,
Plant ID: 2T48-SV F368 Solenoid Valve Located in the Torus Room ASCO Model NP8320A185E Service: Solenoid Valve for Sensing Line Isolation Valve 2T48-F361B TER EQUIPMENT ITEM NO: 56 Plant ID: 2T48-SV F367 Solenoid Valve Located in the Torus Room ASCO Model NP8320A185E Service: Solenoid Valve for Sensing Line Isolation Valve 2T48-F361B TER EQUIPMENT ITEM No: 56 Plant ID: 2T48-SV F366 Solenoid Valve Located in the Torus Room ASCO Model NP8320A185E l
Service: Solenoid Valve for Sensing Line Isolation Valve 2T48-F361A TER EQUIPMENT ITEM No: 56 Plant ID: 2T48-A0V F365 Solenoid Valve Located in the Torus Room ASCO Model NP8320A185E Service: Solenoid Valve for Sensing Line Isolation Valve 2T48-F361A a'
1
TER EQUIPMENT ITEM No: 57 !
Plant ID: 2T48-SV F373 Solenoid Valve Located in the Reactor Building, Elev. 130'0" ASCO Model NP8320A185E Service: Solenoid Valve for Sensing Line Isolation Valve 2T48-F363A TER EQUIPMENT ITEM NO: 5/
Plant ID: 2T48-SV F376 Solenoid Valve Located in the Reactor Building, Elev. 130'0" ASCO Model NP8320A185E Service: Solenoid Valve for Sensing Lina Isolation Valve 2T48-F363B TER EQUIPMENT ITEM NO: 57 Plant ID: 2T48-SV F3f5 Solenoid Valve Located in the Reac;. BuildinF;, Elev.130'0" ASCO Model NP8320A185!!
Service: Solenoid Valve for Sensir.g Line Isolation Valve 2I48-F363B TER EQUIPMENT ITEM No: 57 Plant ID: 2T48-SV F374 Solenoid Valve Located in the Reactor Building, Elev. 130'0" ASCO Model NP8320A185E Service: Solenoid Valve for Sensing Line Isolation Valve 2T48-F363A TER EQUIPMENT ITEM NO: 58 Plant ID: 2P41-A0V F039A,B Solenoid Valve Located in the Southeast Corner Room ASCO Model NP206-380-3F Service: RHR Core Spray Room Cooler 3A & 3B Inlet TER EQUIPMENT ITEM NO: 58 Plant ID: 2P41-A0V F037B.D Solenoid Valve Located in the Southeast Corner Room ASCO Model NP206-380-3F Service: RHR Pump Cooler C002B & D TER EQUIPMENT ITEM No: 58 Plant ID: 2P41-SV F037A.C Solenoid Valve Located in the Southeast Corner Room ASCO Model NP206-380-3F Service: RHR Pump Cooler C002A & C Inlet TER EQUIPMENT ITEM NO: 58 Plant ID: 2P41-A0V F036A,B Solenoid Valve Located in the Southeast Corner Room ASCO Model NP206-380-3F Service: RHR Core Spray Room Cooler 2A & 2B
. - _ ~ . - - . _ - _ _ . __ __ . _ . - - - .- _ .- .
i TER EQUIPMENT ITEM NO: 58 Plant ID: 2P41-A0V F035A,B Solenoid Valve Located in the Southeast Corner Room ASCO Model NP206-380-4F Service: HPCI Pump Room C/R B005A & B 4
TER EQUIPMENT ITEM No: 59 i Plant ID: 2B31-A0V F020 l Solenoid Valve Located in the Reactor Building, Elev. 185'0" i
ASCO Model NF206-380-3F Service: Reactor Water Sample Isolation Valve TER EQUIPMENT ITEM NO: 59 Plant ID: 2G51-A0V F017 Solenoid Valve Located in the Southeast Corner Room ASCO Model NP206-380-3F Service: Torus Water Clean-up Isolation TER EQUIPMENT ITEM No: 59 Plant ID: 2P33-A0V F015 Solenoid Valve Located in the Torus Room ASCO Model NP206-380-3F g Service: H yand 0 Containment 2
Isolation Valve TER EQUIPMENT ITEM NO: 59 -
Plant ID: 2P33-A0V F014 '
Solenoid Valve Located in the Torus Room ASCO Model NP206-380-3F Service: H 2and 0 Containment 2
Isolation Valve TER EQUIPMENT ITEM No: 59 Plant ID: 2P33-A0V F013 Solenoid Valve Located in the Torus Room ASCO Model NP206-380-3F Service: H 2and 0 Containment 2
Isolation Valve TER EQUIPMENT ITEM NO: 59 Plant ID: 2P33-A0V F012 Solenoid Valve Located in the Reactor Building, Elev. 130'0" ASCO Model NP206-380-3F Service: H yand 0 Containment 2
Isolation Valve TER EQUIPMENT ITEM No: 59 Plant ID: 2P33-AOV F011 Solenoid Valve Located in the Reactor Building, Elev. 130'0" ASCO Model NP206-380-3F Service: H yand 0 Containment 2
Isolation Valve h
J J
b
\
- TER EQUIPMENT ITEM NO
- 59 Plant ID: 2P33-A0V F010 Solenoid Valve Located in the Reactor Building, Elev.185'0" ASCO Model NP206-380-3F Service: H 2and 0 Containment Isolation Valve 2
TER EQUIPMENT ITEM NO: 59 Plant ID: 2P33-A0V F007 Solenoid Valve Located in the Torus Room ASCO Model NP206-381-3F Service: H 2and 0 Containment Isolation Valve 2
TER EQUIPMENT ITEM NO: 59 Plant ID: 2P33-A0V F006 Solenoid Valve Located in the Torus Room ASCO Medel NP206-381-3F Service: H 2and 0 Containment Isolation Valve 2
TER EQUIPMENT ITEM No: 59 Plant ID: 2P33-A0V F005 Solenoid Valve Located in the Torus Room ASCO Model NP206-381-3F Service: H and 0 Containment Isolation Valve O
2 2
, TER EQUIPMENT ITEM NO: 59 -
, Plant ID: 2P33-A0V F004 Solenoid Valve Located in the Reactor Building Elev. 130'0" ASCO Model NP206-381-3F Service: H and 0 Containment Isolation Valve 2 2 TER EQUIPMENT ITEM No: 59 Plant ID: 2P33-A0V F003 Solenoid Valve Located in the Reactor Building Elev. 130'0" 3SCO Model NP206-381-3F Service: H and O yContainment Isolation Valvi 2
TER EQUIPMENT ITEM NO: 59 Plant ID: 2P33-A0V F002
, Solenoid Valve Located in the Reactor Building Elev. 185'0" ASCO Model NP206-381-3F Service: H and 0 Containment Isolation Valve 2 2 TER EQUIPMENT ITEM NO: 60 Plant ID: 2E41-A0V F025 i Solenoid Valve Located in the HPCI Room ASCO Model NP206-381-3F Service: Condensate Pump Discharge Drain Isolation Valve l
('~
(
1
. - - - . . , . - - . - - - - -, -.- ,, =
i
/
N-J \
i TER EQUIPMENT ITEM NO: 60 Plant ID: 2E41-A0V F026 Solenoid Valve Located in the HPCI Room ASCO Model NP206-381-3F Service: Condensate Pump Discharge Drain Isolation Valve TER EQUIPMENT ITEM NO: 61 Plant ID: 2E41-A0V F029 Solenoid Valve Located in the HPCI Room ASCO Model NP206-381-3F Service: Steam Pot Drain Isolation Valve TER EQUIPMENT ITEM NO: 61 Plant ID: 2E41-A0V F028 Solenoid Valve Located in the HPCI Room ASCO Model Nd206-381-3F Service: Steam Poc Drain Isolation Valve TER EQUIPMENT ITEM NO: 62 Plant ID: 2 Ell-A0V F122A,B Solenoid Valve Located in the Containment ASCO Model NP8320A186V Service: Testable Check Bypass O TER EQUIPMENT ITh'M NJ: 62 Plant ID: 2E21-A0V F037A B Solenoid Valve Located in the Containment ASCO Model NP8320A186V Service: Testable Lheck Bypass TER EQUIPMENT ITEM NO: 63 Plant ID: 2 Ell-SV F079A,B Solenoid Valve Located in the Northeast and Southeast Corner Rooms Target Rock Model 75F004 Service: RRR HX Discharge Header Sample TER EQUIPMENT ITEM NO: 63 Plant ID: 2 Ell-SV F080A B Solenoid Valve Located in the Northeast and Southeast Corner Rooms Target Rock Model 75F004 Service: RHR HX Discharge Header Sample TER EQUIPMENT ITEM NO: 64 Plant ID: 2B21-A0V F013A C.E,H,K,L,M Solenoid Valve Located in the Containment Target Rock Model 1/2 SMS-A-01-1 Service: ADS v
('
TER EQUIPMENT ITEM NO: 65 Plant ID: 2E11-SV F074A,B Solenoid Valve Located in the Torus Room Target Rock Model 75F010 Service: Service Wster in HX A & B to Drywell TER EQUIPMENT ITEM NO: 66 Plant ID: 2E41-SV F053 Solenoid Valve Located in the HPCI Room Target Rock Model 75F005 Service: Condensate Drain Pot to Barometric Condenser TER EQUIPMENT ITEM NO: 67 Plant ID: 2B21-SV F112 Solenoid Valve Located in the Reactor Building, Elev. 130'0" Valcor Model V5266040 Service: Sample Isolation from Jet Pumps TER EQUIPMENT ITEri NO,1 68 Plant ID: 2B21-SV F111 Solenoid Valve Located in the Reactor Building, Elev. 130'0"
-s Valcor Model V5266040 f)
\s_/
Service: Sample Isolation from Jet Pumps TER EQUIPi!ENT ITEM No: 69 Plant ID: 2E41-SV F121 Solenoid Valve Located in the HPCI Room Valcor Model V5265295 Service: Sample Return Isolation to Torus TER EQUIPMENT ITEM NO: 70 Plant ID: 2G51-F013 Limit Switches Located in the Southeast Corner Room NAMCO Model EA740-20000/EA740-20100 Service: Torus Water Clean-up Isolation Valve i
TER EQUIPMENT ITEM NO: 73 Plant ID: 2B21-A0V F028A,B,C,D Limit Switches Located in the Pipe Chase NAMCO Model EA740-80000/EA740-80001 Service: Main Steam Line Isolation TER EQUIPMENT ITEM NO: 74 Plant ID: 2B21-A0V F022A,B C.D Limit Switches Located in the Containment NAMCO Model EA740-80000/EA740-80001 Service: Main Steam Line Isolation
O TER EQUIPMENT ITEM NO: 75 Plant ID: 2B21-A0V F077A,B Limit Switches Located in the Pipe Chase NAMCO Model EA180-31302 & EA180-32302 Service: Feedwater Check Valve TER EQUIPMENT ITEM No: 75 Plant ID: 2B21-A0V F076A,B Limit Switches Located in the Pipe Chase NAMCO Model EA180-31302 & EA180-32302 Service: Feedwater Check Valve TER EQUIPMENT ITEM NO: 76 Plant ID: 2G51-A0V F011 Limit Switches Located in the Torus Room NAMCO Model EA740-20000 Service: Torus Water Clean-up Isolation Valve TER EQUIPMENT ITEM NO: 76 Plant ID: 2G51-A0V F012 Limit Switches Located in the Torus Room NAMCO Model EA740-20000 Service: Torus Water Clean-up Isolation Valve TFR EQUIPMENT ITEM NO: 77 -
Plant ID: 2B31-A0V F019 Limit Switches Located in the Containment NAMCO Model EA180-31302 Service: Sample Line TER EQUIPMENT ITEM NO: 77 Plant ID: 2E11-A0V F122A,B Limit Switches Located in the Containment
, NAMCO Model EA180-31302 l Service: Testable Check Bypass TER EQUIPMENT ITEM NO: 77 Plant ID: 2E21-A0V F037A,B Limit Switches Located in the Containment NAMCO Model EA180-31302 Service: Testable Check Bypass TER EQUIPMENT ITEM NO: 78 i Plant ID: 2T48-A0V F341 Limit Switches Located in the Torus Room NAMCO Model EA180-31302 Service: Containment Isolation Valve d
/
TER EQUIPMENT ITEM NO: 78 s Plant ID: 2T48-A0V F103 Limit-Switches Located in the Torus Room NAMCO Model EA180-31302 & EA180-32302 - >
Service: Drywell Torus Purge s TER EQUIPMENT ITEM NO: 78 Plant ID: 2T48-A0V F364A,B Limit Switches Located in the Torus Room NAMCO Model EA180-31302. s Service: Sensing Line Isointion -
TER EQUIPMENT ITEM NO: 78 Plant ID: 2T48-A0V F362A,B Limit Switches Located in the Torus Room NAMCO Model EA180-31302 Service: Sensing Line Isolation TER EQUIPMENT ITEM NO: 78 Plant ID: 2T48-A0V F361A,B Limit Switches Located in the Torus Room NAMCO Model EA180-31302 Service: Sensing Line Isolation
(-~s
\v) TER EQUIPMENT ITEM NO: 79 Plant ID: 2E11-A0V F065A,B,C D
, Limit Switches Located in the Torua Room NAMCO Model EA180-31302 8,EA180-32302 Service: RHR Pump C002A,B.C.D Suction Valve TER EQUIPMENT ITEM NO: 79 Plant ID: 2E21-A0V F019A,B Limit Switches Located in the Toruc Room NAMCO Model EA180-31302 & EA180-32302 Service: Suppression Chamber Isolation Valve -
TER EQUIPMENT ITEM NO: 79 _
Plant ID: 2E41-A0V F051 Limit Switches Located in the Torus Room NAMCO Model EA180-31302 4 EA180-32302 Service: Suppression, Pool St(etion. Isolation Valve v;
s . _
TER EQUIPMENT ITEM NO: 79 , -
Plant ID: 2E51-A0V F003 Limit Switches Located in the Torus Room.
NAMCO Model EA180-31302 & EA180-32302 -
Service: Suppression Pool Suction Isolation Valve m.
~
A '%
"1 , ,. ~
._ r .,, . . _ _ . ~ , , _ , , _.. ,,- , , - - - .,
i
(
i (.;
a im -
t \
TER EQUIPMENT ITEM MO: 79 Plant ID: 2T48-A0V F311 Limit Switches Located in the Torus Room NAMCO Model EA180-31302 & EA180-32302 Service: Torus Pressure Equal. Valve TER EQUIPMENT ITEM NO: 79 g Plant ID: 2T48-A0V F310 Limit Switches Located in the Torus Room IIAMCO Model EA180-31302 & EA180-32302 Service: Torus Pressure Equal. Valve
\ TER EQUIPMENT ITEM NO: 79 N '
Plsnt ID: 2T48-A0V F309 Limit Switches Located in the Torus Room NAMCO Model EA180-31302 & EA180-32302
. - Service: Totus Purge Air Inlet
\
TER EQUIPMENT ITEM NO: 73
\ Plant ID: 2I48-A0V F308 u Limit Switches Located in the Torus Room NAMCO Model EA180-31302 & EA180-32302 Service: Drywell Purge Air Inlet 0\
TER EQUIPMENT ITEM NO: 79 -
o Plant ID: 2T48-A0V F307
, Limit Switch <m Located in the Torus Room
?
18JtCO Model EA180-31302 & EA180-32302
' Service: . Inlet Valve to Drywell w,
TER EQUIPMENT ITEM NO: 79 Plant ID: 2T48-A0V F318 Limit SwitcLes Located in the Torus Room i
NAMC0,Model EA180-31302 & EA180-32302
- Service Outlet Valve from Torus
. ,'TER_ EQUIPMENT ITEM NO: 79 x, Plant IDb 2T48-A0V F324 Limit 1Svitches Located in the Torus Room NAYCO Fodel EA180-31302 & EA180-32302
.s
( Seivice: Torus Purge Air Inlet Nej ~ ' TER EQUIPMENT ITEM NO: 79 J. .
Plant ID: 2T48-A0V F326
.C Limit: Switches Located in the Torus Room n ., ;NiciC0 Model EA180-31302 & EA180-32302 C4 Sctrice: Outlet Valve from Torus 1- , ,
J.\ (U my t V ,
'Y
- g. \ \
, .4 2 , , - - . . .
i 5;;
g ,,*
j
& A '
TER EQUIPMENT ITEMiNO: 80 Plant ID: 2Gil-F003 Limit Switches Located in the Torus Room NAMCO Model EA180-34302 Service: Drywell Floor Drain Pump Isolation Valve t
TER EQUIPMENT ITEM NO: 80 Plant ID: 2Gil-F004 Limit Switches Located in the Torus Room NAMCO Model EA180-34202 Service: Drywell Floor Drain Pump Isolation Valve TER EQUIPMENT ITEM NO: '80 Plant ID: 2Gil-F019 Limit Switches Located in the Torus Room NAMCO Model EA180-34302 Service: DrywellEquihmentDrainPumpIsolationValve
}TEREQUIPMENTITEMIDI}802(
Plant ID: 2G11-F029, ' , ,, ~
Limit Switches Located in the Torus Room NAMCO Model EA130-343024 m, Service: Drywell Et}gipment' Drain Isolation Valve
's
( ,,
t D~,
- TER;E(idIPMENT ITEM N05 ;' 80
[' -
Plane ID:, 2T48-A0V F212 Limit Switches Located in the Torus Room NAMCO Model EA180-34302 Service: Drywell Torus DP System ,
- ?: . ,
TER EOUl? MENT ITEM N0t 80 Plant ID: 2T48-A0V r209 Limit Switches Located in the Pipe Penetration Room 8
NAMCO Model EA180-34302 /
Service: Drywell Torus DP System 6' TER EQUIPMENT ITEM NO: 80 i Plant ID: 2T48-A0V F210 Limit Switches Located in the Pipe Penetration Room NAMCO Model EA180-34302 ;,
Service: Drywell Torus DP System (
- g, i TER EQUIPMENT ITEM NO: 80 .,
, Plant ID: 2T48-A0V F211 ,'
< Limit Switches Located in the Torus Room '
NAMCO Model EA180-34302 Service: Drywell Torus DP System
~
f '
)
(}- .
} 4 i '
. ' I ', , ! j g' /
./ . ; s
> j' o i
i
I V
TER EQUIPMENT ITEM NO: 81 Plant ID: 2T48-A0V F332A,B Limit Switches Located in the Torus Room NAMCO Model EA180-31302 Service: Containment Isolation Valve TER EQUIPMENT ITEM NO: 81 Plant ID: 2T48-A0V F333A,B Limit Switches Located in the Torus Room NAMCO Model EA180-31302 Service: Containment Ieolation Valve TER EQUIPMENT ITEM NO: 81 Plant ID: 2T48-A0V F339 Limit Switches Located in the Torus Room NAMCO Model EA180-31302 Service: Containment Isolation Valve TER EQUIPMENT ITEM NO: 81 Plant ID: 2T48-A0V F338 Limit Switches Located in the Torus Room NAMCO Model EA180-31302 Service: Containment Isolation Valve TER EQUIPMENT ITEM NO: 82 -
Plant ID: 2T48-A0V F363A B Limit Switches Located in the Reactor Building, Elev. 130'0" NAMCO Model EA180-31302 Service: Sensing Line Isolation TER EQUIPMENT ITEM NO: 83 Plant ID: 2E41-A0V F028 Limit Switches Located in the HPCI Room NAMCO Model EA180-31302 Service: Steam Fot Drain Isolation Valve TER EQUIPMENT ITEM NO: 83 Plant ID: 2E41-A0V F029 Limit Switches Located in the HPCI Room i
NAMCO Modcl EA180-31302
, Service: Steam Pot Drain Isolation Valve l TER EQUIPMENT ITEM NO: 83 l Plant ID: 2E41-A0V F026 l
Limit Switches Located in the HPCI Room NAMCO Model EA180-31302 Service: Condensate Pump Discharge Drain Isolation Valve lO
o TER EQUIPMENT ITEM NO: 83 Plant ID: 2E41-A0V F025 Limit Switches Located in the HPCI Room NAMCO Model EA180-31302 Service: Condensate Pump Discharge Drain Isolation Valve TER EQUIPMENT ITEM NO: 84 Plant ID: 2B31-A0V F020 Limit Switches Located in the Reactor Building, Elev. 185'0" NAMCO Model EA180-31302 Service: Reactor Water Sample Isolation Valve TER EQUIPMENT ITEM NO: 84 Plant ID: 2P33-A0V F002 Limit Switches Located in the Reactor Building, Elev. 185'0" NAMCO Model EA180-31302 Service: H and 0 Containment Isolation Valve 2 2 TER EQUIPMENT ITEM NO: 84 Plant ID: 2P33-A0V F010 Limit Switches Located in the Reactor Building Elev. 185'0" NAMCO Model EA180-31302 Service: H and 0 Containment Isolation Valve 2 2 TER EQUIPMENT ITEM NO: 84 Plant ID: 2P70-A0V F001A Limit Switches Located in the Reactor Building, Elev. 158'0" NAMCO Model EA180-31302 Service: Drywell Nitrogen Make-up IER EQUIPMENT ITEM NO: 84 Plant ID: 2P70-A0V F002 Limit Switches Located in the Reactor Building, Elev. 158'0" NAMCO Model EA183-31302 Service: Containment Isolation Valve TER EQUIPMENT ITEM No: 84 4 Plant ID: 2P70-A0V F003 l Limit Switches Located in the Reactor Building, Elev. 158'0" NAMCO Model EA180-31302 Service: Containment Isolation Valve TER EQUIPMENT ITEM NO: 84 Plant ID: 2P70-A0V F004 Limit Switches Located in the Reactor Buf1 ding, Elev. 158'0" NAMCO Model EA180-31302 Service: Containment Isolation Valve O
I
, _ . , _ _ _ , - , _ . - , ,_ .- ._ _ ., _ _ _ _ _ _ _ _ , . m
v TEP EQUIPMENT ITEM No: 84 Plant ID: 2P70-A0V F005 Limit Switches Located in the Reactor Building,.Elev. 158'0" NAMCO Model EA180-31302 Service: Containment Isolation Valve TER EQUIPMENT ITEM NO: 84 Plant ID: 2T41-A0V F003B Limit Switches Located in the Reactor Building, Elev. 203'0" NAMCO Model EA180-31302 & EA180-32302 Service: Out. Refueling Floor Fans 2A & 2B TER EyUIPMENT ITEM NO: 84 Plant ID: 2T41-A0V F011B Limit Switches Located ia the Reactor Building, Elev. 185'0" NAMCO Model EA180-31302 & EA180-32302 Service: Reactor Zone Sup. Fan Isolation Damper TER EQUIPMENT ITEM NO: 84 Plant ID: 2T41-A0V F023A Limit Switches Located in the Reactor Building, Elev. 203'0" NAMCO Model EA180-31302 & EA180-32302
-~g Servi:e: Refueling Floor Exhaust Isolation Damper Rea. Bldg. Vent System s- TER EQUIPMENT ITEM NO: 84 -
Plant ID: 2T48-A0V F319 Limit Switches Located in the F2 actor Building, Elev. 185'0" NAMCO Model EA180-31302 & EA180-32302 Service: Outlet Valve from Drywell TER EQUIPMENT ITEM NO: 84 Plant ID: 2T48-A0V F320 Limit Switches Located in the Reactor Building, Elev. 185'0" NAMCO Model EA180-31302 & EA180-32302 Service: Outlet Valve from Drywell TER EQUIPMENT ITEM NO: 85 Plant ID: 2D11-A0V F050 Limit Switches Located in the Reactor Building Elev. 130'0" NAMCO Model EA180-31302 Service: Fission Products Sample Isolation Valve TER EQUIPMENT ITEM NO: 85 Plant ID: 2D11-A0V F052 Limit Switches Located in the Reactor Building, Elev. 130'0" NAMCO Model EA180-31302 Service: Fission Products Sample Isolation Valve 4
a
(
TER EQUIPMENT ITEM No: 85 Plant ID: 2G51-A0V F017 Limit Switches Located in the Southeast Corner Room NAMCO Model EA180-31302 Service: Torus Water Clean-up Isolation TER EQUIPMENT ITEM NO: 86 Plant ID: 2T48-A0V F334A,B Limit Switches Located in the Reactor Building, Elev. 185'0" NAMCO Model EA180-31302 Service: Containment Isolation Valve TER EQUIPMENT ITEM NO: 86 Plant ID: 2T48-A0V F335A.B Limit Switches Located in the Reactor Building, Elev. 185'0" NAMCO Model EA180-31302 Service: Containment Isolation Valve TER EQUIPMENT ITEM NO: 86 Plant ID: 2T48-A0V F340 Limit Switches Located in the Reactor Building, Elev. 185'0" NAMCO Model EA180-31302 e- s Service: Containment Isolation Valve TER EQUIPMENT ITEM NO: 87 -
Plant ID: 2P33-A0V F007 Limit Switches Located in the Torus Room NAMCO Model EA180-31302 Service: H and 0 Containment Isolation Valve 2 2 TER EQUIPMENT ITEM NO: 87 Plant ID: 2P33-A0V F013 Limit Switches Located in the Tcrus Roon NAMCO Model EA180-31302 l
Service: H and 0 Containment Isolation Valve 2 2 TER EQUIPMENT ITEM NO: 87 Plant ID: 2P33-A0V F014 Limit Switches Located in the Torus Room NAMCO Model EA180-31302 Service: H 2and 0 Containment 2
Isolation Valve TER EQUIPMENT ITEM NO: 87 Plant ID: 2P33-A0V F015 l Limit Switches Located in the Torus Room l NAMCO Model EA180-31302 Service: H and 0 Containment Isolation Valve 2 2
(
TER EQUIPMENT ITEM NO: 87 Plant ID: 2T48-A0V F104 Limit Switches Located in the Torus Room NAMCO Model EA180-31302 Service: Containment Isolation Valve TER EQUIPMENT ITEM NO: 87 Plant ID: 2T48-A0V F113 Limit Switches Located in the Torus Room NAMCO Model EA180-31302 Service: Containment Isolation Valve TER EQUIPMENT ITEM NO: 87 Plant ID: 2T48-A0V F114 Limit Switches Located in the Torus Room NAMCO Model EA180-31302 Service: Containment Isolation Valve TER EQUIPMENT ITEM NO: 87 Plant ID: 2T48-A0V F115 Limit Switches Located in the Torus Room NAMCO Model EA180-31302 g'~N Service: Containment Isolation Vajve TER EQUIPMENT ITEM NO: 87 -
Plant ID: 2T46-A0V F116 Limit Switches Located in the Torus Room i
NAMCO Model EA180-31302 Service: Containment Isolation Valve TER EQUIPMENT ITEM NO: 87 Plant ID: 2T48-A0V F118A,B Limit Switches Located in the Torus Room NAMCO Model EA180-31302 Ser" ice: Containment Isolation Valve TER EQUIPMENT ITEM NO: 87 Plant ID: 2T48-A0V F321 Limit Switches Located in the Torus Room NAMCO Model EA180-31302 Service: Containment Isolation Valve TER EQUIPMENT ITEM NO: 87
! Plant ID: 2T48-A0V F322 l Limit Switches Located in the Torus Rooz l
NAMCO Model EA180-31302 Service: Containment Isolation Valve l
a l
l l
l t
O TER EQUIPMENT ITEM NO: 87 Plant ID: 2T48-A0V F325 Limit Switches Located in the Torus Room NAMCO Model EA180-31302 Service: Containment Isolation Valve TER EQUIPMENT ITEM NO: 87 Plant ID: 2T48-A0V F327 Limit Switches Located in the Torus Room NAMCO Model EA180-31302 Service: Containment Isolation Valve TER EQUIPMENT ITEM NO: 88 Plant ID: 2P33-A0V F003 Limit Switches Located in the Reactor Building, Elev. 130'0" NAMCO Model EA180-31302 Service: H 2and 0 Containment 2
Isolation Valve TER EQUIPMENT ITEM NO: 88 Plant ID: 2P33-A0V F004 Limit Switches Located in the Reactor Building, Elev. 130'0" NAMCO Mode] EA180-31302
"'s Service: H and 0 Containment Isolation Valve 2 2
- s. - -
TER EQUIPMENT ITEM NO: 88 Plant ID: 2P33-A0V F011 Limit Switches Located in the Reactor Building, Elev. 130'0" NAMCO Model EA180-31302 Service: H and 0 Containment Isolation Valve 2 2 TER EQUIPMENT ITEM NO: 88 Plant ID: 2P33-A0V F012 Limit Switches Located in the Reactor Building, Elev. 130'0" NAMCO Model EA180-31302 Service: H and 0 Containment Isolation Valve 2 2 TER EQUIPMENT ITEM NO: 89 Plant ID: 2P41-A0V F066 Limit Switches Located in the Torus Room NAMCO Model EA180-31302 & EA180-32302 Service: Plant Service Water Inlet Div. 1 TER EQUIPMENT ITEM No: 89 Plant ID: 2P41-A0V F067 Limit Switches Located in the Torus Room NAMCO Model EA180-31302 & EA180-32302 c Service: Plant Service Water Inlet Div. 2
m U
TER EQUIPMENT ITEM NO: 89 Plant ID: 2T46-A0V F001B Limit Switches Located in the Reactor Building, Elev. 185'0" NAMCO Model EA180-31302 & EA180-323302 Service: Inlet Damper to Filter B TER EQUIPMENT ITEM No: 90 Plant ID: C82 Transfer Switch Control Switch Located in the Reactor Building, Elev. 130'0" General Electric Model SBl Service: Transfer Switch TER EQUIPMENT ITEM NO: 100 Plant ID: 2B21-PS N301A,B,C D.E F,G.H,K,L,M Pressure Switch Located in the Containment Pressure Controls Inc. Model A17-1P Service: SRV Monitoring TER EQUIPMENT ITEM NO: 107 Plant ID: 2E11-PS N017A,B,C,D Pressure Switch Located in the Northeast & Southeast Corner Room Model: Static-Ring-0-Ring Model 7924-100 Service: RHR Service Water Valve F068A & B Permissive TER EQUIPMENT ITEM NO: 133,191 Plant ID: 2T48-PT N003A,B Pressure Transmitter Located in the Reactor Building, Elev. 158'0" Rosemount Model 1153GB7 Service: Drywell Pressure Wide Range TER EQUIPMENT ITEM NO: 133 Plant ID: 2T48-PT N023A,B Pressure Transmitter Located in the Reactor Building, Elev. 158'0" Rosemount Model 1153GB6 Service: Drywell Pressure Mid Range TER EQUIPMENT ITEM NO: 133 Plant ID: 2T48-LT N021A Pressure Transmitter Located in the RCIC (NW) Corner Room Rosemount Model 1153DB6 Service: Torus Water Level Narrow Range I
l l
l
- t-i
O TER EQUIPMENT ITEM NO: 133,191 Plant ID: 2T48-PT N020A,B Pressure Transmitter Located in the Reactor Building, Elev.158'0" Rosemount Model 1153GB5 Service: Containment Pressure Narrow Range TER EQUIPMENT ITEM NO: 133 Plant ID: 2T48-LT N010A Pressure Transmitter Located in the RCIC(NW) Corner Room Rosemour.t Model 1153DB5 Service: Torus Water Level Wide Range TER EQUIPMENT ITEM NO: 135 Plant ID: 2E21-C001A,B Electric Motor Located in the Northeast and Southeast Corner Rooms General Electric Model SK6339XC117A Service: Core Spray Pump TER EQUIPMENT ITEM No: 135 Plant ID: 2E11-C002A,B,C.D Electric Motor Located in the Northeast and Southeast Corner Rooms General Electric Model SK6339XC115A Service: RHR Pump
^
TER EQUIPMENT ITEM No: 138 Plant ID: 2T41-B002A,B Electrical Motor Located in the Southeast Corner Room Joy Manufacturing Reliance Model 36211750 Service: Core Spray and RHR Pump Room Cooling TER EQUIPMENT ITEM NO: 138 Plant ID: 2T41-B003A,B Electrical Motor Located in the Northeast Corner Room Joy Manufacturing Reliance Model 36211750 Service: Core Spray and RHR Pump Room Cooling TER EQUIPMENT ITEM NO: 138 Plant ID: 2T41-B004A,B Electrical Motor Located in the RCIC Room Joy Manufacturing Reliance Model 23141750 Service: RCIC Pump Room Coolers TER EQUIPMENT ITEM No: 138 Plant ID: 2T41-B005A,B l Electrical Motor Located in the HPCI Room Joy Manufacturing Reliance Model 23141750 Service: HPCI Pump Room Coolers
)
k TER EQUIPMENT ITEM NO: 140 Plant ID: 2T52
, Electrical Penetration Located Inside/Outside the Drywell, Elev.151'6" General Electric Model F01 Service: Cable Penetration TER EQUIPMENT ITEM NO: 141 Plant ID: 2E32-B001B,F K,P Electric Heater Located in the Torus Room General Electric Model 47D513673 Service: Heater for MSIV Leakage Control System TER EQUIPMENT ITEM NO: 144 Plant ID: 2D11-RE N003A,B Radiation Monitor Located in the Containment Victoreen Model 8771 Service: Containment High Range Radiation Monitoring TER EQUIPMENT ITEM NO: 145 Plant ID: 2R11-S033 Transformer Located in the Reactor Building Elevation 130'0" General Electric Model 9T23B3893 O Service: MCC 2R24-S012 TER EQUIPMENT ITEM NO:
Plant ID: 2R11-S031 145 '
Transformer Located in the Reactor Building Elevation 130'0" General Electric Model 9T23B3893 Service: MCC 2R24-S011 TER EQUIPMENT ITEM NO: 147 Plant ID: 2R24-S018B i Motor Control Center Located in the Reactor Building Elevation 130'0"
- Allis Chalmera Model Valueline Mark I Service
- Electrical Power Distribution I
TER EQUIPMENT ITEM NO: 147 Plant ID: 2R24-S018A Motor Control Center Located in the Reactor Building Elevation 130'0" Allis Chalmers Model Valueline Mark I Service: Electrical Power Distribution TER EQUIPMENT ITEM NO: 147 Plant ID: 2R24-S012 Motor Control Center Located in the Reactor Building Elevation 130'0" Allis Chalmers Model Valueline Mark I Service: Electrical Power Distribution l
l l
i
l
('~
\
l l
TER EQUIPMENT ITEM NO: 147 Plant ID: 2R24-S011 Motor Control Center Located in the Reactor Building Elevation 130'0" Allis Chalmers Model Valueline Mark I Service: Electrical Power Distribution TER EQUIPMENT ITEM NO: 148 Plant ID: 2R27-S093 Motor Starter, DC Located in the Reactor Building Elevation 130'0" General Electric Model 7700 Service: Electrical Power Distribution TER EQUIPMENT ITEM NO: 148 Plant ID: 2R27-SC96 Motor Starter, DC Located in the Reactor Building Elevation 130'0" General Electric Model 7700 Service: Electrical Power Distribution TER EQUIPMENT ITEM No: 148 Plant ID: 2R24-S022 Motor Starter DC Located in the Reactor Building Elevation 130'0" General Electric Model 7700 Service: Electrical Power Distribution O,' 148 '
TER EQUIPMENT ITEM NO:
Plant ID: 2R24-5021 Motor Starter, DC Located in the Reactor Building Elevation 130'0" General Electric Model 7700 Service Electrical Power Distribution TER EOUIPMENT ITEM NO: 149 Plant ID: 2R27-S095 Motor Starter, DC Located in the HPCI Room General Electric Model 7700 Service: Motor Power TER EQUIPMENT ITEM NO: 149 Plant ID: 2R27-S094 Motor Starter, DC Located in the HPCI Room General Electric Model 7700 Service: Motor Power TER EQUIPMENT ITEM NO: 150 Plant ID: RPT Switchgear Switchgear Located in the Reactor Building, Elev. 185'0" Westinghouse Model 50DHP250 Service: Recirculation Pump Trip O
V
b v
TER EQUIPMENT ITEM NO: 152,154,155 Plant ID: States Type NT Terminal Block Located Inside/Outside the Drywell States Model ZWM Service: Terminal Block TER EQUIPMENT ITEM NO: 156 Plant ID: PVC Heat Shrink Electrical Cable Splice Located Outside the Drywell Raychem Model HVMC5303000 Service: # 2-1/C # 250 MCM TER EQUIPMENT ITEM NO: 157 Plant ID: PWC Heat Shrink Electrical Cable Splice Located Outside the Drywell Raychem Model HVT I A 1 20C Service: # 2/0 & # 3/0 AWG, 8KV, #250 MCM, #350 MCM, #500 MCM TER EQUIPMENT ITEM NO: 158,159 Plant ID: PWH Heat Shrink Electrical Cable Splice Located Inside/Outside the Drywell Raychem Model WCSF1156N Service: # 9 AWG, 600V TER EQUIPMENT ITEM NO: 159 Plant ID: PVT Heat Shrink Electrical Cable Splice Located Inside/Outside the Drywell Raychem Model WCSF0706N Service: # 18 to # 10 Gauge Wire TER EQUIPMENT ITEM No: 159 Plant ID: PWJ Heat Shrink Electrical Cable Splice Located Outside the Drywell l Raychem Model WCSF0706N Service: # 2, # 1, # 10 & # 2/0 AWG 600V l TER EQUIPMENT ITEM NO: 159 l Plant ID: PWI Heat Shrink Electrical Cable Splice Located Outside the Drywell Raychem Model WCSF0706N Service: # 6 & # 4 AWG, 600V l TER EQUIPMENT ITEM NO: 159 Plant ID: PWL Heat Shrink Electrical Cable Splice Located Outside the Drywell Raychem Model WCSF0706N Service: # 350 & # 500 MCM, 600V O
l
O V
TER EQUIPMENT ITEM NO: 159 Plant ID: PWK Heat Shrink Electrical Cable Splice Located Outside the Drywell Raychem Model WCSF0706N Service: # 4/0 & 250 MCM, 600V TER EQUIPMENT ITEM NO: 167 Piant ID: H04 Electrical Cable Instrument Located Inside/Outside the Drywell Anaconda Wire and Cable Model 600V Service: Instrumentation TER EQUIPMENT ITEM NO: 168 Plant ID: N07 Electrical Cable, Instrument Located Outside the Drywell Brand - Rex Model 600V Service: Instrumentation TER EQUIPMENT ITEM NO: 168 Plant ID: N01 Electrical Cable Instrument Located Outside the Drywell Brand - Rex Model 600V Service: Instrumentation TER EQUIPMENT ITEM NO: 168 Plant ID: M19 Electrical Cable Instrument Located Outside the Drywell Brand - Rex Model 600V Service: Instrumentation TER EQUIPMENT ITEM NO: 168 Plant ID: H02 Electrical Cable Instrument Located Outside the Drywell Brand - Rex Model 600V Service: Instrumentation TER EQUIPMENT ITEM NO: 168 Plant ID: H01 Electrical Cable Instrument Located Outside the Drywell Brand - Rex Model 600V Service: Instrumentation TER EQUIPMENT ITEM NO: 169,170,171,172,174 Plant ID: # 14 SIS Vulkene Electri:al Cable Located Outside the Drywell General Electric Model ,I5727511 Service: G. E. Panel Wiring O
ss l TER EQUIPMENT ITEM NO:, 175 Plant ID: B09 Electrical Cable, PowI2r Located Outside the Drywell Okonite Model 1000V ;
Service: Power TER EQUIPMENT ITEM NO:, 175 Plant ID: B08 Electrical Cable, Pow 2r Located Outside the Drywell Okonite Model 1000V ,
Service: Power TER EQUIPMENT ITEM No':_ 175 Plant ID: B07 Electrical Cable, Pow tr Located Outside the Drywell Okonite Model 1000V Service: Power TER EQUIPMENT ITEM Noi 175 Plant ID: B06 :
Electrical Cable Powbr Located Outside the Drywell Okonite Model 1000V
('~'
Service: Power k
TER EQUIPMENT ITEM N0( 175 -
Plant ID: B04 Electrical Cable Powe r Located Outside the Drywell Okonite Model 1000V Service: Power TER EQUIPMENT ITEM NO:' 175 Plant ID: B03 Electrical Cable Power Located Outside the Drywell Okonite Model 1000V Service: Power TER EQUIPMENT ITEM NO: :175 Plant ID: B01 Electrical Cable, Power l Located Outside the Drywell Okonite Model 1000V Service: Power TFR EQUIPMENT ITEM No: 175 Plant ID: B17 Electrical Cable, Power Located Outside the Drywell Okonite Model 1000V Service: Power
TER EQUIPMENT ITEM NO: 175 Plant ID: B13 Electrical Cable, Power Located Outside the Drywell Okonite Model 1000V Service: Power TER EQUIPMENT ITEM No: 175 Plant ID: B12 Electrical Cable Power Located Inside/Outside the Drywell Okonite Model 1000V Service: Power TER EQUIPMENT ITEM No: 175 Plant ID: Bil Electrical Cable, Power Located Outside the Drywell Okonite Model 1000V Service: Power TER EQUIPMENT ITEM NO: 176 Plant ID: A05 Electrical Cable, Power Located Outside the Drywell Okonite Model 5000V Service: Power TER EQUIPMENT ITEM NO: 176 Plant ID: A06 Electrical Cable, Power Located Outside the Drywell Okonite Model 5000V Service: Power TER EQUIPMENT ITEM NO: 177,178 Plant ID: C20 Electrical Cable, Control Located Inside/Outside the Drywell Okonite Model 600V Service: Control TER EQUIPMENT ITEM NO: 177,178 Plant ID: C19 Electrical Cable Control Located Inside/Outside the Drywell Okonite Model 600V Service: Control l
O
l
('"') l s_/
s TER EQUIPMENT ITEM NO: 178 Plant ID: C18 Electrical Cable, Control Located Outside the Drywell Okonite Model 600V Service: This sheet applies to valves 2 Ell-A0V F065A,B,C D Only TER EQUIPMENT ITEM NO: 178 Plant ID: C17 Electrical Cable, Control Located Inside the Drywell Okonite Model 600V Service: Control TER EQUIPMENT ITEM NO: 178 Plant ID: C21 Electrical Cable, Control Located Outside the Drywell Okonite Model 600V Service: Control TER EQUIPMENT ITEM NO: 178 Plant ID: C25 Electrical Cable, Control Located Outside the Drywell Okonite Model 600V p Service: Control s- TER EQUIPMENT ITEM NO: 178 s Plant ID: C24 Electrical Cable. Control Located Outside the Drywell Okonite Model 600V Service: Control TER EQUIPMENT ITEM NO: 178 Plant ID: C22 Electrical Cable, Control Located Outside the Drywell Okonite Model 600V Service: Control TER EQUIPMENT ITEM NO: 178 Plant ID: C23 Electrical Cable, Control Located Outside the Drywell Okonite Model 600V Service: Control TER EQUIPMENT ITEM NO: 178 Plant ID: C33 Electrical Cable, Control Located Outside the Drywell Okonite Model 600V Service: Power h
/
~./
e 4
, - - - - ~
3 F - ,y - - y. - , .- - + -w-- - - - --.- - - - -- ---
O TER EQUIPMENT ITEM NO: 178 Plant ID: C30 Electrical Cable, Control Located Outside the Drywell Okonite Model 600V Service: Power TER EQUIPMENT ITEM NO: 178 Plant ID: C29 Electrical Cable. Contro? Located Outside the Drywell Okonite Model 600V Service: Power TER EQUIPMENT ITEM NO: 178 Plant ID: C27 Electrical Cable. Control Located Outside the Drywell Okonite Model 600V Service: Control TER EQUIPMENT ITEM NO: 178 Plant ID: C26 Electrical Cable, Control Located Outside the Drywell Okonite Model 600V f Service: Control
\
'- TER EQUIPMENT ITEM NO: 178 -
Plant ID: D09 Electrical Cable, Control Located Outside the Drywell Okonite Model 600V Service: Power TER EQUIPMENT ITEM NO: 178 Plant ID: D08 Electrical Cable, Control Located Outside the Drywell Okonite Model 600V Service: Power TER EQUIPMENT ITEM NO: 178 Plant ID: C42 Electrical Cable, Control Located Outside the Drywell Okonite Model 600V 4 Service: Power TER EQUIPMENT ITEM NO: 178 Plant ID: C40 Electrical Cable. Control Located Outside the Drywell Okonite Model 600V Service: Control L) i
I
\s_ /
TER EQUIPMENT ITEM NO: 178 Plant ID: B02 Electrical Cable Control Located Outside the Drywell Okonite Model 600V Service: Control TER EQUIPMENT ITEM NO: 178 Plant ID: C36 Electrical Cable, Control Located Outside the Drywell Okonite Model 600V Service: Power TER EQUIPMENT ITEM NO: 178 Plant ID: C32 Electrical Cable, Control Located Outside the Drywell Okonite Model 600V Service: Power TER EQUIPMENT ITEM NO: 178 Plant ID: M13 Electrical Cable Control Located Outside the Drywell Okonite Model 600V Service: Power TER EQUIPMENT ITEM NO: 178 -
Plant ID: C21 Electrical Cable Control Located Inside the Drywell Okonite Model 600V Service: Control TER EQUIPMENT ITEM NO: 178 Plant ID: C11 Electrical Cable Control Located Outside the Drywell Okonite Model 600V Service: Control TER EQUIPMENT ITEM No: 179 Plant ID: K01 Electrical Cable Instrument Located Outside the Drywell Samuel Moore Model 300v Service: Instrumentation TER EQUIPMENT ITEM NO: 180,173 Plant ID: 2Dil-RE N003A,B Electrical Cable, Located in the Containment Victoreen Model 878-1-5 Service: Radiation Monitoring s
I
()
TER EQUIPMENT ITEM NO: 187 Plant ID: 2E51-MOV F105 ,
Motorized Valve Actuator Located in the Torus Room 1 Limitorque Model SMB, AC Service, Class B Insulation Service: Exhaust to Torus Penetration TER EQUIPMENT ITEM NO: 187 Plant ID: 2 Ell-MOV F140A,B Motorized Valve Actuator Located in the Torus Room Limitorque Model SMB, AC Service, Class B Insulation Service: HPCI Discharge to HX A and HX B TER EQUIPMENT ITEM NO:' 188 Plant ID: 2 Ell-MOV F015A,B Motorized Valve Actuator Located in the Pipe Penetration Room Limitorque Model SMB, AC Service, Class RH Insulation Service: LPCI Discharge Valve TER EQUIPMENT ITEM NO: 189 Plant ID: 2T48-MOV F027 Motorized Valve Actuator Located in the Reactor Building, Elev. 130'0" Linitorque Model SMB00 Service: Nitrogen Inerting
() TER EQUIPMENT ITEM NO: 192 Plant ID: 2 Ell-MOV F028A,B Motorized Valve Actuator Located in the Torus Room Limitorque Model SMB, AC Service, Class B Insulation Service: Inlet to Support Pool l
v
O The following equipment was not addressed in Franklin Research Center's Technical Evaluation Report. However, the equipment is part of Georgia Power Company's I. E. Bulletin 79-OlB Qualified Equipment List.
Plant ID: 2D11-A0V F051 ,
Limit Switches Located in the Pipe Penetration Room NAMCO Model EA180-31302 Service: Fission Products Sample Isolation Viv.
Plant ID: 2Dil-A0V F053 Limit Switches Located in the Pipe Penetration Room NAMCO Model EA180-31302 Service: Fission Products Sample Isolation Viv.
Plant ID: 2P33-A0V F005 Limit Switches Located in the Torus Room NAMCO Model EA180-31302 Service: H and 0 Containment Isolation Viv.
2 2 Plant ID: C35 Power Cable Located Outside the Drywell Okonite Model 4/C - # 4 AWG 600-V Insulation Service: Power
() Plant ID: C41 Power Cable Located Outside the Drywell Okonite Model 5/C - # 9 AWG 600-V Insulation Service: Power Plant ID: PWD Heat Shrink Electrical Cable Splice Located Outside the Drywell Raychem Corp. Model HVT-I-A-1-20E Service: # 350 MCM, 8KV Plant ID: PWE Heat Shrink Electrical Cable Splice Sleeve Located Outside the Drywell Raychem Corp. Model HVT-I-A-2-20F Service: # 500 MCM, 8KV Plant ID: Terminal Tape Insulating Tape Located Outside the Drywell Okonite Model T95 Insulating Tape Service: Insulation of Termination and Splices Plant ID: Jacketing Tape Protective Tape Located Outside the Drywell Okonite Model T35 Jacketing Tape Service: Protection of Termination and Splices O
k Plant ID: PWD Heat Shrink Wire and Cable Located Outside the Drywell Raychem Corp. Model HVT-I-A-1-20E Service: # 350 MCM, 8KV Plant ID: PWE Heat Shrink Wire and Cable Sleeve Located Outside the Drywell Raychem Corp. Model HVT-I-A-2-20F Service: # 500 MCM, 8KV Plant ID: Terminal Tape Insulating Tape Located Outside the Drywell
_0konite Model T95 Insulating Tape Service: Insulation of Termination and Splices 4
Plant ID: Jacketing Tape Protective Tape Located Outside the Drywell Okonite Model T35 Jacketing Tape Service: Protection of Termination and Splices 1
1
O Plant ID: PWB Heat Shrink Electrical Cable Splice Located Outside the Drywell Raychem Corp. Model HVT-I-A-1-20C Service: Insulation of Termination and Splices f
J G
1
)
l 2
!O 1
I r\
( I N_/
s I l
The following equipment is part of new design changes and not presently I installed. However, when installed this equipment will be added to the I. E.
Bulletin 79-01B Equipment List and will be qualified.
Plant ID: 2P70-PS N006A,B Pressure Switch Located in Reactor Building, Elev. 158' 0" ITT Barton Model 580A-2 Service: Air Receiver 2P70-A001 Plant ID: 2P70-FT NO20A,B Flow Transmitter Located in Reactor Building, Elev. 158' 0" Rosemount Model 1153-DB3PA Service: Drywell Pneumatic System High Flow Isolation Plant ID: 2P70-FT NO22A,B Flow Transmitter Located in Reactor Building, Elev. 130' 0" Rosecount Model 1153-DB3PA Service: Drywell Pneumatic System High Flow Isolation Plant ID: 2C11-SV F040 Solanoid Valve Located in Reactor Building, Elev. 130' 0" ASCO Model NP8323A22E
'~' Service: Scram Discharge Valve Isolation Ss! Plant ID: 2P70-SV E004 -
Solenoid Valve Located in Reantor Building, Elev. 130' 0" Target Rock Model 1121010 Service: Drywell Pneumatic System High Y1owTs'Tation o
Plaat ID: 2P70-SV F005 Solenoid Valve Located in Reactor Building, Elev. 130' 0" Target Rock Model 1121010 i Service: Drywell Pneumatic System High Flow Isolation Plant ID: 2P70-SV F066 Solenoid Valve Located in Reactor Building, Elev. 158' 0" Target Rock Model 1121010 Service: Drywell Pneumatic System High Flow Isolation Plant ID: 2P70-SV F067 Solenoid Valve Located in Reactor Building, Elev. 158' 0" l Target Rock Model 1121010 Service: Drywell Pneumatic System High Flow Isolation Plant ID: 2P70-SV F001B Solenoid Valve Located in Reactor Building, Elev. 158' 0" Valcor Model V526-5920-5 Service: Backup Nitrogen Supply Line d
\
Plant ID: 2 Ell-SV F213 Solenoid Valve Located in Reactor Building, Elev. 130' 0" ASCO Model NP8320A185E
- Service
- Pilot Valve for Q2E11-A0V F041A Plant ID: 2 Ell-SV F214 Solenoid Valve Located in Reactor Building, Elev. 130' 0" ASCO Model NP8320A185E Service: Pilot Valve for Q2 Ell-A0V F041A Plant IL: 2 Ell-SV F215 Solenoid Valve Located in Reactor Building, Elev. 130' 0" ASCO Model NP8320A185E Service: Pilot Valve for Q2 Ell-A0V F041B Plant ID: 2E11-SV F216 Solenoid Valve Located in Reactor Building, Elev. 130' 0" ASCO Model NP8320A185E
, Service: Pilot Valve for Q2 Ell-A0V F041B Plant ID: 2E11-SV F217 Solenoid Valve Located in Reactor Building, Elev. 130' 0"
(
g ASCO Model NP8320A185E Service: Pilot Valve for Q2E11-A0V F041C N. ,
Plant ID: 2E11-SV F218 Solenoid Valve Located in Reactor Building, Elev. 130' 0" ASCO Model NP8320A185E Service: Pilot Valve for Q2 Ell-A0V F041C Plant ID: 2E11-SV F219 Solenoid Valve Located in Reactor Building, Elev. 130' 0" ASCO Model NP8320A185E Service: Pilot Valve for Q2E11-A0V F041D Plant ID: 2 Ell-SV F220 Solenoid Valve Located in Reactor Building, Elev. 130' 0"
'ASCO Model NP8320A185E Service: Pilot Valve for Q2E11-A0V F041D Plant ID: 2E11-A0V F041A,B,C,D Limit Switches Located in Reactor Building Elev. 130' 0" NAMCO Model EA180-31302 Service: Sensing Line Isolation V
SECTION C O EQUIPMENT REQUIRING QUALIFICATION CLARIFICATIONS INTRODUCTION This section provides the information and the clarifications required,to address the discrepancies identified by the Nuclear Regulatory Commission (NRC) in the Environmental Qualification Safety Evaluation Report (SER).
Equipment identified by the NRC as requiring information and/or clarifications are those in NRC Qualification Categories I.b. - Equipment Qualification Pending Modification, II.a. - Equipment Qualification Not Established, II.b - Equipment Not Qualified and II.c - Equipment satisfies all requirements except qualified life or replacement schedule justified. The NRC has not classified any Plant Hatch Unit 1 equipment as Qualification Category II.b Georgia Power Company's thirty (30) day response t the NRC Safety Evaluation Report, Revision 0, dated May 6, 1983 addresses the NRC, Discrepancy (s) for equipment in Qualification Categories I,b an II.a. Therefore, this section only addresses equipment in Qualification Category II.c.
The plant identification numbers, locations, manufacturers, model numbers, and plant services are listed for each individual TER equipment item number, followed by the discrepancy (s) noted in the Technical Evaluation Report (TER).
The NRC discrepancy (s) is (are) addressed in the clarification section.
I o
l i
TER EQUIPMENT ITEM NO. 2 Motorized Valve Actuator Located in the Torus Room Plant ID: 2 Ell-MOV F024A B '
Limitorque Model SMB, AC Service, Class RH Insulation Service: RHR Testline Valves NRC DISCREPANCY Aging Dogradation Evaluated Adequately Qualified Life or Replace.nent Scheduled Established A. The. licensee has not provided documented evidence from the manufac';urer that the installed equipment and the test specimen (s) in the referenced report (s) are similar. The licensee has identified only two motori::ed valve actuators that incorporates a motor-brake assembly, yet has reference several reports which tested motorized valve actuators equipped with such devices. The licensee should obtain the information necessary to establish similarity, or submit the same if it is already in their central file (also referencing this information on the System Component Evaluation Worksheets (SCEWs)).
l B. The licensee has cited B0058 for many equipment items in an effort to 4
establish similarity between the installed and tested equipment. It should be noted that Limitorque's generic qualification program is acceptable, but that this report does not in itself establish similarity, nor does it establish a qualified life estimate for this equipment. In order to l establish a qualified life estimate for this equipment, the licensee must completely identify the installed components (i.e. motor lead insulation, type of torque switch) and then calculate a qualified life cased on available information. This available information can come from either
, testing performed prior to environmental testing or from published data.
j None of the referenced reports have calculated a qualified life estimate
- based on an acceptable technique. It should also be noted that the thermal l
aging that has been performed has been done on individual components or simulates only a fraction of the qualified life claimed. No basis has been stated on the report (s) for the times or temperatures chosen for the thermal aging performed. Particular attention should be given to the motor-brake assembly (if any) and the motor lead insulation where Teflon has been used in some cases.
l -CLARIFICATION Documented evidence establishing similarity between the installed equipment and the test specimen is provided by the manufacturer and can be found in Georgia Power Company's Qualification Documentation Files.
l O
- , s a
c i e x f,,
r . N 9
f_.i. x
'\ , T$R EQUIPMENT ITEM NO. 2 (Continued)
':: \
- s. Additionally, FRC states that a qualified life has not been established in an s~ '
accentable manner. The DOR Cuidelines do not require a qualified life to be ,
L' '
l estab iphed for all equipment.'
Cecrgia Power Company has-yerfo:med further evaluation of age sensitive j
components. and, using cvetlable ' test data and published data, established a l
qualified life 'in accordance with.the requirements of the DOR Guidelines.
Therefore, this equipment is,censidered qualified and' Justification for ,
Continued Operation is not required. ,
s x
\ %g
's s s*. g
', i N
s
- 7.+
1, ,\ .
y.z. i . 1 \' ;
w s t s
~- '
- ',, ~ ' '
w s
_. s s ' _ ,
w \ **
\
- s 4
.p I
\
i i
I
/
I l
s i
I
-_ _ _ . , - - m._.,._ _ _ _ , . _. , , _ _ . . . , , _ _ _ , _ .
\ \
wg k
j s x TER EQUIPMENT ITEM NO. 3_
+
Motorized Valve Actuator Located in the Reactor Building Elev. 185'0" Y
Plant ID: 2E11-MOV F023 Limitorque Model SMB, .DC Service, Class R Insulation Service: Vessel Head Spray Isolation Valve i
N3 l NRC' DISCREPANCY f '(\- Aging Degradation. Evaluated Adequately Qualified Life or Replacement Scheduled Established
\ ,
A. The licensee has not provided documented evidence from the manufacturer
- that the installed equipment and the test specimen (s) in the referenced l report (s) are similar. The licensee has identified only two motorized valve actuators that incorporates a motor-brake assembly, yet has reference several reports which tested motorized valve actuators equipped with such devices. The licensee should obtain the information necessary to establish similarity, or submit the same if it is already'in their central file (also referencing this information on the System Component Evaluation Worksheets
^
(SCEWs)).
B. The licensee has cited B0058 for many equipment items in an effort to establish similarity between the installed and tested equipment. It should be noted that Limitorque's generic qualification program is acceptable, but L- that this report does not in itself establish similarity, nor does it l' establish a qualified life estimate for this equipment. In order to
- - e'stablish a qualified life estimate for this equipment, the licensee must 4
completely identify the installed components (i.e. motor lead insulation,
, type of torque switch) and then calculate a qualified life based or.
available information. This available information can come from either testing performed prior to environmental testing or from published data.
None of the referenced reports have calculated a qualified life estimate
- based on an acceptable technique. It should also be noted that the thermal aging that has been performed has been done on individual components or i simulates only a fraction of the qualified life claimed. No basis has been stated on the report (s) for the times or temperatures chosen for the thermal aging performed. Particular attention should be given to the l motor-brake assembly (if any) and the motor lead insulation where Teflon has been used in some cases.
CLARIFICATION o Documented evidence establishing similarity between the installed equipment and the test. specimen ~fs-provided by the manufacturer and can be found in Georgia Power Company's Oualification Documentation Files.
\
s,.
v b
L .
I i . . ,
.t s -
) . / -
TER EQUIPMENT ITEM N0.d.(Continued) s' s Additionally FRC states'that a qualffied life has not been established in an acceptable manner. The DOR'Cuidelines do not require a qualified life to be established for all equipment. g F
Georgfa Power Company has performed further evaluation of age sensitive components and, using available test data and published data, established a qualified life in accordance with the reqpirements of the DOR Guidelines.
Therefore, this equipment is considered qualified and Justification for Continued Operation is not required. , .
c t
N l t >
s 4
1 t
[
1 l
l l
l l
l l
-+w----we e--e-- -e yv w-g --
pwa- -g--.,-y m- -y ,---
[
l TER EQUIPMENT ITEM NO. 4 Motorized Valve Actuator Located in the Pipe Penetration Room ;
Plant ID: 2E41-MOV F003 Limitorque Model SMB, DC Service, Class H Insulation Service: Steam Supply Outboard Isolation Valve i,
NRC DISCREPANCY Aging Degradation Evaluated Adequately Qualified Life or Replacement Scheduled Established ,
A. The licensee has not provided documented eviden :e from the manufacturer that the installed equipment and the test spect sn(s) in the referenced report (s) are similar. The licensee has identified only two motorized valve actuators that inccrporates a motor-brake assembly, yet has reference several reports which tested motorized valve actuators equipped with such devices. The licensee should obtain the information necessary to establish similarity, or submit the same if it is already in their central file (also referencing this information on the System Component Evaluation Worksheets
'p (SCEWs)).
B. The licensee has cited B0058 for many equipment items in an effort to ,
establish similarity between the installed and tested equipment.- It should '
be noted that Limitorque's generic qualification program is acceptable, but that this report does not in itself establish similarity, nor does it I establish a qualified life estimate for this equipment. In order to 4
establish a qualified life estimate for this equipment, the licensee must completely identify the installed components (i.e. motor lead insulation, type of torque switch) and then calculate a qualified life based on available information. Ihis available information can come from either :
l testing performed prior to environmental testing or from published data.
None of the referenced reports have calculated a qualified life estimate based on an acceptable technique. It should also be noted that the thermal l c aging that has been performed has been done on individual components or i
simulates only a fraction of the qualified life claimed. No basis has been stated on the report (s) for the times or temperatures chosen for the thersal aging performed. Particular attention shoald be given to the motor-brake assembly (it any) and the motor lead insulation where Teflon has been used in some cases, j CLARIFICATION
- l Documented evidence establishing similarity between the installed equipment and ,
the test specimen is provided by the manufacturer and can be found in Georgia l Power Company's Qualification Documentation Files. l l
I l 1
i i
TER EQUIPMENT ITEM NO. 4 (Continued)
Additionally, FRC states that a qualified life has not been establishad in an acceptable manner. The DOR Guidelines do not require a qualified life to be established for all equipment.
Georgia Power Company has performed further evaluation of age sensitive components and, using available test data and published data, established a qualified life in accordance with the requirements of the DOR Guidelines.
Therefore, this equipment is considered qualified and Justification for Continued Operation is not required.
I
'O t
I 1
l l
l f
L t
\
. - . _ - - . _ . - _ _ _ _ =
O b
TER EQUIPMENT ITEM NO. ,9_
Motorized Valve Actuator Located in the Reactor Building, Elev. 158'0" Plant ID: 2G31-MOV F004 Limitorque Model SMB, DC Service Class H lasulation Service: Downstream Is,olation Valve l
NRC DISCREPANCY I Aging Degradation Evaluated Adequately n Qualified Life or Replacement Scheduled Established A. The licensee has not provided documented evidence from the manufacturer I
that the installed equipment and the test specimen (s) in the referenced report (s) are similar. The licensee has identified only two motorized valve actuators that incorporates a motor-brake assembly, yet has reference several reports which tested motorized valve actuators equipped with such devices. The licensee should obtain the information necessary to establish similarity, or submit the same if it is already in their central file (also referencing this information on the System Component Evaluation Worksheets (SCEWs)).
B. The licensee has cited B0058 for many equipment items in an effort to establish similarity between the installed and tested equipment. It should be noted that Limitorque's generic qualification program is acceptable, but that this report does not in itsclf establish similarity, nor does it i establish a qualified life estimate for this equipment. In order to
! establish a qualified life estimate for this equipment, the licensee must l completely identify the installed components (i.e. motor lead insulation,
, type of torque switch) and then calculate a qualified life based on
! available information. This aiailable information can come from either l testing performed prior to environmental testing or from published data.
- None of the referenced reports have calculated a qualified life estimate
, based on an acceptable technique. It should also be noted that the thermal j aging that has been parformed has been done on individual components or j simulates only a fraction of the qualified life claimed. No basis has been j stated on the report (s) for the ti:nes or temperatures chosen for the d
thermal aging performed. Particular attention sheuld be given to the motor-brake assembly (if any) and the motor lead insulation where Teflon j has been used in some cases.
I j CLARIFICATION l Documented evidence esta'olishing similarity between the installed equipment and j the test specimen is provided by the manufacturer and can be found in Georgia Power Company's Qualification Documentation Files.
i i
TER EQUIPMENT ITEM NO. 9 (Continued)
Additionally, FRC states that a qualified life has not been established 11. an acceptable manner. The DOR Guidelines do not require a e,ualified life to be established for all equipment.
Georgia Power Company has performed further evaluation of age sensitive components and, using available test data and published data, established a qualified life in accordance with the requirements of the DOR Guidelines.
Therefore, this equipment is considered qualified and Justification for Continued Operation is not required.
i g
I
v TER EQUIPMENT ITEM NO. 11 Motorized Valve Actuator Located in the RWCU HX Room Plant ID: 2E21-MOV F004B Limitorque Model SMB, AC Service, Class H Insulation Service: Core Spray Outboard Valve Plant ID: 2E21-MOV F004A*
Limitorque Model SMB, AC Service, Class H Insulation Service: Core Spray Outboard Valve NRC DISCREPANCY Aging Degradation Evaluated Adequately Qualified Life or Replacement Scheduled Established A. The licensee has not provided documented evidence from the manufacturer that the installed equipment and the test specimen (s) in the referenced report (s) are similar. The licensee has identified only two motorized valve actuators that incorporates a motor-brake assembly, yet has reference several reports which tested motorized valve actuators equipped with such devices. The licensee should obtain the information necessary to establish O. similarity, or submit the same if it is already in their central file (also referencing this information on the System Component Evaluation Worksheets (SCEWs)).
B. The licensee has cited B0058 for many equipment items in an effort to establish similarity between the installed and tested equipment. It should be noted that Limitorque's generic qualification program is acceptable, but that this report does not in itself establish similarity, nor does it establish a qualified life estimate for this equipment. In order to establish a qualified life estimate for this equipment, the licensee must completely identify the installed components (i.e. motor lead insulation,
! type of torque switch) and then calculate a qualified life based on l available information. This available information can come from either testing performed prior to environmental testing or from published data.
None of the referenced reports have calculated a qualified life estimate based on an acceptable technique. It should also be noted that the thermal aging that has been performed has been done on individual components or simulates only a fraction of the qualified life claimed. No basis has been stated on the report (s) for the times or temperatures chosen for the thereal aging performed. Particular attention should be given to the motor-brake assembly (if any) and the motor lead inquiation where Teflon has been used in some cases.
- The location for this valve is Reactor Building Elev. 158'0" O
3 O TER EQUIPMENT ITEM NO. 11 (Continued)
C. However, it is noted that the accident environment is relatively "r on-harsh" and that any combination of components which could be found in Limitorque motorized valve actuators should be able to withstand these conditions. Due to this fact, the only deficiency that exists is that of qualified life.
CLARIFICATION Georgia Power Company has identified the above equipment as not having sufficient documentation to establish qualification. The actuator and motor for the MOV will be replaced with a qualified actuator and motor prior to or during the Unit 2 - 1984 Refueling Outage.
Justification for Continued Operation for this item has been previously submitted to the NRC in Georgia Power Company's response to NRC I. E. Bulletin 79-01B - Environmental Qualification of Class 1E Equipment, Revision 4, dated January 8, 1982 for Edwin I. Hatch Nuclear Plant - Unit 2. The Justification can be found in Section B.3.1.1, on Page 21 and is still applicable.
s -
C j
m a
TER EQUIPMENT ITEM NO. 12 Motorized Valve Actuator Located in the Pipe Penetration Room Plant ID: 2E11-MOV F017A,B Limitorque Model SMB, AC Service, Class RH Insulation Service: LPCI Discharge Valve NRC DISCREPANCY Aging Degradation Evaluated Adequately Qualified Life er Replacement Scheduled Established A. The licensee has not provided documented evidence from the manufacturer that the installed equipment and the test specimen (s) in the referenced report (s) are similar. The licensee has identified only two motorized valve actuators that incorporates a motor-brake assembly, yet has reference several reports which tested motorized valve actuators equipped with such devices. The licensee should obtain the information necessary to establish similarity, or submit the same if it is already in their central file (also referencing this information on the System Component Evaluation Worksheets (SCEWs)).
[ B. The licensee has cited B0058 for many equipment items in an effort to N establish similarity between the installed and tested equipment.' It should be noted that Limitorque's generic qualification program is acceptable, but that this report does not in itself establish similarity, nor does it establish a qualified life estimate for this equipment. In order to establish a qualified life estimate for this equipment, the licensee must completely identify the installed components (i.e. motor lead insulation, type of torque switch) and then calculate a qualified life based on available information. This available information can come from either testing performed prior to environmental testing or from published data.
None of the referenced reports have calculated a qualified life estimate based on an acceptable technique. It should also be noted that the thermal aging that has been performed has been done on individual components or simulates only a fraction of the qualified life claimed. No basis has been stated on the report (s) for the times or temperatures chosen for the thermal aging performed. Particular attention should be given to the motor-brake assembly (if any) and the motor lead insulation where Teflon has been used in some cases.
C_U RIFICATION Documented evidence establishinF similarity between the installed equipment and the test specimen is provided by the manufacturer and can be found in Georgia Power Company's Qualification Documentation Files.
/
O
l l
l l
TER EQUIPMENT ITEM NO. 12 (Continued)
Additionally, FRC states that a qualified life has not been established in an acceptable manner. The DOR Guidelines do not require a qualified life to be established for all equipment.
Georgia Power Company has performed further evaluation of age sensitive components and, using available test data and published data, established a qualified life in accordance with the requirements of the DOR Guidelines.
i Therefore, this equipment is considered qualified and Justification for Continued Operation is not required.
i
(} ,
,--,--------,,,,,,,,-,,,,,,,.,,,-,,,...,-,-,,,,-,,,--,,...,-,,,,_.,,-,,.,-,,------,--n-,- - --
v TER EQUIPMENT ITEM NO. 16 Motorized Valve Actuator Located in the RWCU HX Room Plant ID: 2E21-MOV F005B Limitorque Model SMB, AC Service, Class RH Insulation Service: Core Spray laboard Valve Plant ID: 2E21-MOV F005A*
Limitorque Model SMB, AC Service, Class RH Insulation Service: Core Spray Inboard Valve NRC DISCREPANCY Aging Degradation Evaluated Adequately Qualified Life or Replacement Scheduled Established A. The licensee has not provided documented evidence from the manufacturer that the installed equipment and the test specimen (s) in the referenced report (s) are similar. The licensee has identified only two motorized valve actuators that incorporates a motor-brake assembly, yet has reference p several reports which tested motorized valve actuators equipped with such V)
( devices. The licensee should obtain the information necessary to establish similarity, or submit the same if it is already in their central file (also referencing this information on the System Component Evaluation Worksheets (SCEWs)).
H. The licensee has cited B0058 for many equipment items in an effort to establish similarity between the installed and tested equipment. It should be noted that Limitorque's generic qualification program is acceptable, but that this report does not in itself establish similarity, nor does it establish a qualified life estimate for this equipment. In order to establish a qualified life estimate for this equipment, the licensee must completely identify the installed components (d..e. motor lead insulation,
)' type of torque switch) and then calculate a qualified lifr, based on available information. This available information can come from either testing performed prior to environmental testing or from published data.
None of the referenced reports have calculated a qualified life estimate i based on an acceptable technique. It ehould also be noted that the thermal l
aging that has been performed has been done on individus1 components or simulates only a fraction of the qualified life claimed. No basis has been stated on the report (s) for the times or temperatures chosen for the thermal aging performed. Particular attention should be given to the i motor-brake assembly (if any) and the motor lead insulation where Teflon has been used in some cases.
I Q
- Location of this valve is Reactor Bulding. Elev.158'0" e
r {
\
I l
J TER EQUIPMENT ITEM NO. 16 (Continued) 1 CLARIFICATION
- Georgia Power Company has identified the above equipment as not having sufficient documentation to establish qualification. The actuator ani motor for the MOV will be replaced with a qualified actuator and motor prior to or during
~
the Unit 2 - 1984 Refueling Outage.
Justification for Continued Operation for this item has been previously submitted to the NRC in Georgia Power Company's response to NRC I. E. Bulletin 79-01B - Environmental Qualification of Class IE Equipment, Revision 4, dated January 8, 1982 for Edwin I. Hatch Nuclear Plant - Unit 2. The Justification can be found in Section B.3.1.1, on Page 21 and is still applicable.
O l
l l
O
- - . .- --_- . = -_- - . -..
I i
i l TER EQUIPMENT ITEM NO. 17 Motorized Valve Actuator Located in the HPCI Room Plant ID: 2E41-MOV F001 Limitorque Model SMB, DC Service, Class B Insulation
- Service
- System Isolation Valve Plant ID: 2E41'MOV F041 Limitorque Model SMB, DC Service, Class B Insulation Service: Pump Suction from Suppression Pool 1
I Plant ID: 2E41-MOV F059 Limitorque Model SMB, DC Service, Class B Insulation Service: Booster Pump Discharge to Barometric Condenser Plant ID: 2E41-MOV F007 Limitorque Model SMB, DC Service, Class B Insulation Service: HPCI Pump Outboard Discharge Valve 1 NRC DISCREPANCY
/ Aging Degradation Evaluated Adequately Qualified Life or Replacement Scheduled Established -
A. The licensee has not provided documented evidence from the manufacturer that the installed equipment and the test specimen (s) in the referenced report (s) are similar. The licensee has identified only two motorized valve actuators that incorporates a motor-brake assembly, yet has reference several reports which tested motorized valve actuators equipped with such devices. The licensee should obtain the information necessary to establish similarity, or submit the same if it is already in their central file (also referencing this information on the System Component Evaluation Worksheets (SCEWs)) .
- B. The licensee has cited B0058 for many equipment items in an effort to i
establish similarity between the installed and tested equipment. It should be noted that Limitorque's generic qualification program is acceptable, but that this report does not in itself establish similarity, nor does it establish a qualified life estimate for this equipment. In order to l establish a qualified life estimate for this equipment, the licensee must completely identify the installed components (i.e. motor lead insulation, i
type of torque switch) and then calculate a qualified life based on l available information. This available information can come from either testing performed prior to environmental testing or from published data.
I None of the referenced reports have calculated a qualified life estimate based on an acceptable technique. It should also be noted tnat the thermal i aging that has been performed has been done on individual ccoponents or f ' simulates only a fraction of the qualified life claimed. Ne basis has been stated on the report (s) for the times or temperatures choseri for the thermal aging performed. Particular attention should be giyen to the j motor-brake assembly (if any) and the motor lead insulationgwhere Teflon j has been used in some cases.
-,.----+----.e. -- - - - - -
-.,.-mg- yw ct 3 w.---m -
--m----- y,- a-- ,w-, - =.4w% ui e e.-, . ,aw.my -y igi,-m-am ee- - -ww-.e.m _-we--w-,-i- m-e +
I I
i TER EQUIPMENT ITEM NO. 17 (Continued)
C. However, it is noted that the accident environment is relatively "non-harsh" and that any combination of components which could be found in Limitorque motorized valve actuators should be able to withstand these l conditions. Due to this fact, the only deficiency that exists is that of j qualified life.
CLARIFICATION Documented evidence establishing similarity between the installed equipment and the test specimen is provided by the manufacturer and can be found in Georgia Power Company's Qualification Documentation Files.
Additionally, FRC states that a qualified life has not been established in an acceptable manner. The DOR Guidelines do not require a qualified life to be established for all equipment.
J Georgia Power Company has performed further evaluation of age sensitive
~
l components and, using available test data and published data, established a qualified life in accordance with the requirements of the DOR Guidelines.
Therefore, this equipment is considered qualified and Justification for
~'
Continued Operation is not required.
O V
i
l l
)
%./
TER EQUIPMENT ITEM NO. 10 Motorized Valve Actuator Located in the Northeast and Southeast Corner Rooms Plant ID: 2E11-MOV F011A,B Limitorque Model SMB, AC Service, Class B Insulation Service: RHR HX A & B to RCIC Plant ID: 2 Ell-MOV F026A B Limiterque Model SMB, AC Service, Class B Insulation Service: RHR HX A & B to RCIC Plant ID: 2E11-MOV F003B Limitorque Model SMB, AC Service Class B Insulation Service: Heat Exchanger Discharge Valve Plant ID: 2E11-MOV E048A,B Limitorque Model SMB, AC Service, Class B Insulation Service: RHR HX A & B Bypass Valve Plant ID: 2E11-MOV F004A,B,C,D Limitorque Model SMB, AC Service, Class B Insulation
_s Service: RHR Pump C002A,B,C,D Suction Valve T
s,,,/ Plant ID: 2 Ell-MOV F006B -
Limitorque Model SMB, AC Service, Class B Insulation Service: Shutdown Cooling Suction Isolation Valve Plant ID: 2E11-MOV F007A.B Limitorque Model SMB, AC Service, Class B Insulation Service: Pump C002A&C Minimum Flow Bypass Plant ID: 2 Ell-MOV F006A.C.D Limitorque Model SMB, AC Service, Class B Insulation Service: Shutdown Cooling Suction Isolation Valve i Plant ID: 2E11-MOV F047A,B Limitorque Model SMB, AC Service, Class B Insulation Service: RHR HX A 1 B to Inlet Valve Plant ID: 2E21-MOV F001A,B Limitorque Model SMB, AC Service, Class B Inselation Service: Pump C001A,B Valve l
l Plant ID: 2E21-MOV F015A.B l Limitorque Model SMB, AC Service, Class B Insulation j Service: Test Bypass Valve Plant ID: 2E21-MOV F031A,B Limitorque Model SMB, AC Service, Class B Insulation
.'s- Service: Minimum Flow Bypass Valve i
_ _ _ _ ~_ _ . _ _ _ _ _. _ _ _ _ _ _ _ _ . . . . ._ _ . _
O TER EQUIPMENT ITEM NO. 18 (Continued)
Plant ID: 2E11-MOV F104A B Limitorque Model SMB, AC Service Class B Insulation a
Service: RHR HX A & B Ventilation >
i Plant ID: 2E11-MOV F103A,B Limitorque Model SMB, AC Service, Class B Insulation i Service: RHR HX A & B Ventilation NRC DISCREPA11Y Aging Degradation Evaluated Adequately Qualified Life or Replacement Scheduled Established A. The licensee has not provided documented evidence from the manufacturer that the installed equipment and the test specimen (s) in the referenced report (s) are similar. The licensee has identified only two motorized valve actuators that incorporates a motor-brake assembly, yet has reference several reports which tested motorized valve actuators equipped with such devices. The licensee should obtain the information necessary to establish similarity, or submit the same if it is already in their central file (also referencing this information on the System Component Evaluation Worksheets
-(SCEWs)).
B. The ifcensee has cited B0058 for many equipment items in an effort to establish similarity between the installed and tested equipment. It should be noted that Limitorque's generic qualification program is accepttble, but that this report does not in itself establish similarity, nor does it establish a qualified life estimate for this equipment. In order to establish a qualified life estimate for this equipment, the licensee must completely identify the installed components (i.e. motor lead insulation, type of torque switch) and then calculate a qualified life based on available information. This available information can come from either testing performed prior to environmental testing or from published data.
None of the referenced reports have calculated a qualified life estimate based on an acceptable technique. It should also be noted that the thermal aging that has been performed has been done on individual components or aimulates only a fraction of the qualified life claimed. No basis has been stated on the report (s) for the times or terperatures chosen for the thermal aging performed. Particular attention should be given to the motor-brake assembly (if any) and the motor lead insulation where Teflon has been used in some cases.
C. However, it is noted that the accident environment is relatively "non-harsh" and that any combination of components which could be found in Limitorque motorized valve actuators should be able to withstand these conditions. Due to this fact, the only deficiency that exists is that of qualific.d life.
O
i TER EQUIPMENT ITEM NO. 18 (Continued)
CLARIFICATION Documented evidence establishing similarity between the installed equipment and the test specimen is provided by the manufacturer and can be found in Georgia Power Company's Qualification Documentation Files.
l Additionally, FRC states that a qualified life has not been established in an acceptable manner. The DOR Guidelines do not require a qualified life to be established for all equipment.
Georgia Power Company has performed further evaluation of age sensitive components and, using available test data and published data, established a qualified life in accordance with the requirements of the DOR Guidelines.
Therefore, this equipment is considered qualified and Justification for Continued Operation is not required.
E
\w
i TER EQUIPMENT ITEM NO. 19 Motorized Valve Actu 2or Located in the Torus Room Plant ID: 2E11-MOV F091A,B Limitorque Model SMB, AC Service, Class RH Insulation Service: HPCI Discharge to HX A & B NRC DISCREPANCY Aging Degradation Evaluated Adequately Qualified Life or Replacement Scheduled Established A. The licensee has not provided documented evidence from the manufacturer
- that the installed equipment and the test specimen (s) in the referenced report (s) are similar. The licensee has identified only two motorized valve actuators that incorporates a motor-brake assembly, yet has reference several reports which tested motorized valve actuators equipped with such devices. The licensee should obtain the information necessary to establish similarity, or submit the same if it is already in their central file (also j referencing this information on the System Component Evaluation Worksheets i[ '
B.
(SCEWs)).
The licensee has cited B0058 for many equipment items in an effort"to establish similarity between the installed and tested equipments It should be noted that Limitorque's generic qualification program is acceptable, but that this report does not in itself establish similarity, nor does it establish a qualified life estimate for this equipment. In order to establish a qualified life estimate for this equipment, the licensee must completely identify the installed components (i.e. motor lead insulation, type of torque switch) and then calculate a qualified life based on available information. This available information can come from either testing performed prior to environmental testing or from published data.
None of the referenced reports have calculated a qualified life estimate based on an acceptable technique. It should also be noted that the thermal aging that has been performed has been done on individual components or simulates only a fraction of the qualified life claimed. No basis has been stated on the report (s) for the times or temperatures chosen for the thermal aging performed. Particular attention should be given to the motor-brake assembly (if any) and the motor lead insulation where Teflon has been used in some cases.
CLARIFICATION j Documented evidence establishing similarity between the installed equipment and the test specimen is provided by the manufacturer and can be found in Georgia Power Company's Qualification Documentation Files.
.. = . .- _ . _ - .
, \s_
TER EQUIPMENT ITEM NO. 19 (Continued)
Additionally FRC states that a qualified life has not been established in an acceptable manner. The DOR Guidelines do not require a qualified life to be established for all equipment.
Georgia Power Company has performed further evaluation of age sensitive components and, using available test data and published data, established a qualified life in accordance with the requirements of the DOR Guidelines. ,
Therefore, this equipment is considered qualified and Justification for Continued Operation is not required.
m, -. . . _ . . - - - , - - . -.v._. .- .._,4w--* ..m.. m- --.-4, ----.-. ---- -- ---.---,--- .__ _ _ _ _______ - _ _ - __
O TER EQUIPMENT ITEM NO. 29 Motorized Valve Actuator Located in the Reactor Building, Elev. 185'0" Plant ID: 2T49-MOV F002A,B Limitorque Model SMB, AC Service, Class B Insulation Service: Gas from Drywell Outboard Isolation Valve Plant ID: 2T49-MOV F001A,B Limitorque Model SMB, AC Service, Class B Insulation Service: Gas from Drywell Outboard Isolation Valve NRC DISCREPANCY Aging Degradation Evaluated Adequately Qualified Life or Replacement Scheduled Established
, A. The licensee has not provided documented evidence from the manufacturer that the installed equipment and the test specimen (s) in the referenced report (s) are similar. The licensee has identified only two motorized valve actuators that incorporates a motor-brake assembly, yet has reference several reports which tested motorized valve actuators equipped with such devices. The licensee should obtain the information necessary to establish similarity, or submit the same if it is already in their central file (also
, referencing this information on the System Component Evaluation Worksheets i (SCEWs)).
B. The licensee has cited B0058 for many equipment items in an effort to establish similarity between the installed and tested equipment. It should be noted that Limitorque's generic qualification program is acceptable, but that this report does not in itself establish similarity, nor does it establish a qualified life estimate for this equipment. In order to itablish a qualified life estimate for this equipment, the licensee must ompletely identify the installed components (i.e. motor lead insulation,
- cype of torque switch) and then calculate a qualified life based on available information. This available information can come from either testing performed prior to environmental testing or from published data.
None of the referenced reports have calculated a qualified life estimate based on an acceptable technique. It should also be noted that the thermal aging that has been performed has been done on individual components or simulates only a fraction of the qualified life claimed. No basis has been stated on the report (s) for the times or temperatures chosen for the thermal aging performed. Particular attention should be given to the motor-brake assembly (if any) and the motor lead insulation where Teflon has been used in some cases.
l l
0
TER EQUIPMENT ITEM NO. 29 (Continued)
C. However, it is noted that the accident environment is relatively "non-harsh" and that any combination of components which could be found in Limitorque motorized valve actuators should be able to withstand these conditions. Due to this fact, the only deficiency that exists is that of qualified life.
CLARIFICATION Documented evidence establishing similarity between the installed equipment and the test specimen is provided by the manufacturer and can be found in Georgia Power Company's Qualification Documentation Files.
Additionally, FRC states that a qualified life has not been established in an acceptable manner. The DOR Guidelines do not require a qualified life to be established for all equipment.
Georgia Power Company has performed further evaluation of age sensitive j
components and, using available test data and published data, established a qualified life in accordance with the requirements of the DOR Guidelines.
Therefore, this equipment is considered qualified and Justification for Continued Operation.is not required.
l l
l k
l TER EQUIPMENT ITEM NO. 31 Motorized Valve Actuator Located in the Northeast and Southeast Corner Rooms Plant ID: 2 Ell-MOV F068A,B Limitorque Modsl SMB, AC Service, Class B Insulation Service: RHR Service Water Flow Control Plant ID: 2T49-MOV F006A,B Limitorque Model SMB, AC Service Class B Insulation Service: Feedwater from RHR to Cooler Isolation Valve NRC DISCREPANCY Aging Degradation Evaluated Adequately Qualified Life or Replacement Scheduled Established
, A. The licensee has not provided documented evidence from the manufacturer that the installed equipment and the test specimen (s) in the referenced report (s) are similar. The licensee has identified only two motorized valve actuators that incorporates a motor-brake asseably, yet has reference several reports which tested motorized valve actuators equipped with such devices. The licensee should obtain the information necessary to establish similarity, or submit the same if it is already in their central file (also referencing this information on the System Component Evaluation Worksheets (3CEL)).
B. The licensee has cited B0058 for many equipment items in an affort to establish similarity between the installed and tested equipment. It should be noted that Limitorque's generic qualification program is acceptable, but that this report does not in itself establish similarity, nor does it establish a qualified life urimate for this equipment. In order to establish a qualified life estimate for this equipment, the licensee must completely identify the installed components (i.e. motor lead insulation, type of torque switch) and then calculate a qualified life based on available information. This available information can come from either testing performed prior to environmental testing or from published data.
None of the referenced reports have calculated a qualified life estimate based on an acceptable technique. It should also be noted that the thermal aging that has been performed has been done on individual components or simulates only a fraction of the qualified life claimed. No basis has been stated on the report (s) for the times or temperatures chosen for the thertaal aging performed. Particular attention should be given to the motor-brake essembly (if any) and the motor lead insulation where Teflon has been used in some cases.
O
O TER EQUIPMENT ITEM NO. 31 (Continued)
C. However, it $s noted that the accident environment is relatively "non-harsh" and that any combination of components which could be found in Limitorque motorized valve actuators should be able to withstand these conditions. Due to this fact, the only deficiency that exists is that of qualified life.
CLARIFICATION Documented evidence establishing similarity between the installed equipment and the test specimen is provided by the manufacturer and can be found in Georgia Power Company's Qualification Documentation Files.
Additionall7, FRC states that a qualified life has not been established in an acceptable manner. The D0R Guidelines do not require a qualified life to be established for all equipment.
Georgia Power Company has performed further evaluation of age sensitive components and, using available test data and published data, established a qualified life in accordance with the requirements of the DOR Guidelines.
Therefore, this equipment is considered qualified and Justification for Continued Operation is not required.
\ -
d
O TER EQUIPMENT ITEM No. 36 Mo?.orized Valve Actuator Located in the Reactor Building, Elev. 130'0" Plant !D: 2P64-MOV F047 Limitorque Model SMB, AC Service, Class B Insulation Service: Primary Containment Isolation Plant ID: 2P64-MOV F045 Limitorque Model SMB, AC Service, Class B Insulation Service: Primary Containment Isolation NRC DISCREPANCY Aging Degradation Evaluated Adequately Oualified Life or Replacement Scheduled Established A. The licensee has not provided documented evidence from the manufacturer that the installed equipment and the test specimen (s) in the referenced report (s) are similar. The licensee has identified only two motorized valve actuators that incorporates a motor-brake assembly, yet has reference several reports which tested motorized valve actuators equipped with such devices. The licensee should obtain the information necessary to establish
(, similarity, or submit the same if it is already in their centra ( file (also referencing this information on the System Component Evaluation Worksheets (SCEWs)).
B. The licensee has cited B0058 for many equipment items in an effort to establish similarity between the installed and tested equipment. It should be noted that Limitorque's generic qualification program is acceptable, but that this report does not in itself establish similarity, nor does it establish a qualified life estimate for this equipment. In order to establish a qualified life estimate for this equipment, the licensee must completely identify the installed components (i.e. motor lead insulation, type of torque switch) and then calculate a qualified life based on available information. This available information can come from either testing performed prior to environmental testing or from published data.
None of the referenced reports have calculated a qualified life estimate based on an acceptable technique. It should also be noted that the thermal aging that has been performed has been done on individual components or simulates only a fraction of the qualified life claimed. No basis has been stated on the report (s) for the times or temperatures chosen for the thermal aging performed. Particular attention should be given to the motor-brake assembly (if any) and the motor lead insulation where Teflon has been used in some cases.
O lV l
l
[
V TER EQUIPMENT ITEM NO. 36 (Continued)
C. However, it is noted that the accident environment is relatively "non-harsh" and that any combination of components which could be found in Limitorque mottrized valve actuators should be able to withstand these conditions. Due to this fact, the only deficiency that exists is that of qualified life.
CLARIFICATION Documented evidence establishing similarity between the installed equipment and the test specimen is provided by the manufacturer and can be found in Georgia Power Company's Qualification Documentation Files.
Additionally, FRC states that a qualified life has not been established in an acceptable manner. The DOR Guidelines do not require a qualified life to be established for all equipment.
Georgia Power Company has performed further evaluation of age sensitive components and, using available test data and published data, established a qualified life in accordance with the requirements of the DOR Guidelines.
Therefore, this equipment is considered qualified and Justification for
/'~ Continued Operation is not required.
\ s i
l l
l l
1 l
l 1
l 0
O 1 l
l
O TER EQUIPMENT ITEM No. 37 Motorized Valve Actuator Located in the Torus Room Plant ID: 2E51-MOV 7104 Limitorque Model SMB, AC Service, Class RH Insulation Service: Exhaust to Torus Penetration NRC DISCREPANCY Aging Degradation Evaluated Adequately Qualified Life or Replacement Scheduled Established A. The licensee has not provided documented evidence from the manufacturer that the installed equipment and the test specimen (s) in the referenced report (s) are similar. The licensee has identified only two motorized valve actuators that incorporates a motor-brake assembly, yet has reference several reports which tested motorized valve actuators equipped with such devices. The licensee should obtain the information necessary to establish similarity, or submit the same if it is already in their central file (also referencing this information on the System Component Evaluation Worksheets (SCEWs)).
O B. The licensee has cited B0058 for many equipment items in an effort to establish similarity between the installed and tested equipments It should be noted that Limitorque's generic qualification program is acceptable, but that this report does not in itself establish similarity, nor does it establish a qualified life estimate for this equipment. In order to establish a qualified life estimate for this equipment, the licensee must completely identify the installed components (i.e. motor lead insulation, type of torque switch) and then calculate a qualified life based on available information. This available information can come from either testing performed prior to environmental testing or from published data.
None of the referenced reports have calculated a qualified life estimate based on an acceptable technique. It should also be noted that the thermal aging that has been performed has been done on individual components or simulates only a fraction of the qualified life claimed. No basis has been i stated on the report (s) for the times or temperatures chosen for the j thermal aging performed. Particular attention should be given to the motor-brake assembly (if any) and the motor lead insulation where Teflon has been used in some cases. :
CLARIFICATION Documented evidence establishing similarity between the installed equipment and the test specimen is provided by the manufacturer and can be found in Georgia Power Company's Qualification Documentation Files.
l I
i i
l TER EQUIPMENT ITEM NO. 37 (Continued) l l
Additionally, FRC states that a qualified life has not been established in an
! acceptable manner. The DOR Guidelines do not require a qualified life to be established for all equipment.
i Georgia Power Company has performed further evaluation of age sensitive components and, using available test data and published data, established a qualified life in accordance with the requirements of the DOR Guidelines.
- Therefore, this equipment is considered qualified and Justificatien for Continued Operation is not required.
.G
. - ~ - . ,..,.--,w, c.. ,, -- - ---- --. , , . . - - - , - - .,-- . , - . , - - -
y ,7 - -
i w! -
i
- s s'
it ,- '
}-
N
~ ,.- ,
m - ., ',
\. .' , - - c L% %
'y _
\ .- .
m 'N p ; - -
. s.c \ . 4 s,
- TER EQUIPMENT ITEM No. 53 .
T .. , 1 3 Solenoid Val.ve Located in the Torus. m Room w g g-Plant ID: 2G11-A0V F020 i' s '< '
ASCO Model NP831654E 2,' l ., ..
Service: Drywell Equipment Drain Isolation~-Valve',0
, s.
Plant ID: 2G11-A0V F019 , ', ', \y 1 .
'~ '
ASCO Model NP831654E w,,,,. ' ~ _
V .
1 Service: Drywell Equipment Drain Isolation Valve '- -
s t 3 ,. ..,
1 1 Plant ID: 2G11-A0V F004 ; .
ASCO Model NP831654E ',,_ .'
- iService
- Drywell Floor Drain Pump Isolation Valve J.
3 t ', . '. t;
- l. Plant ID: 2011-A0V F003 .
s -
l ASCO Model NP831654E , 'N '
.\ s' N l Service: Drywell Equipment Drain Isolation Valve ,
', s
- - ;'m, u
\~
, s _
NRC DISCREPANCY D, s E ,
(\ t it -
' Nf -
Qualified Life or Replacement 00hedule Established N 5 ,
q s --
x . , .
The licensee should estab'lish a qualified life eistimate based.' on actual ' '
operating temperatures (i.e. ambient plus heat rice) if normall'y energized and
the available test data.1 \,. , ', - '
CLARIFICATION Themanufacturerrecommendsreplacementofnon-metallicpartsevery'four(4) i s
s
\_'s j years based on the results of the Qualificatioc Tests. Georgia Power Company si t
has established a qualified life of greater than four (4) yurs .. based on ,
activation energies of the non-metallic materials obtained from'ASCO, the aging test time.and f.emperature, plant specific normal temperatures', and the Arrhenius '
s equation.( However, Georgia Power Company is following the manufacturers ,s .
recommendations. ' ' l
. s.
In accordance with the NRC recommendation,' the replacement solenoid valves have been sealed at the conduit entrance with qualified materials which prevent moisture from entering the solenoid valve. ',-
\
i
_ _ . __m-m.-_ . - . - - _ - _ _ _ _ . ____. _.____--m_ - . _ . _ - _ _ . - _ _ _ _ _ - - - - - _ - - - - _-
h yv
\
\ \
O D ;i{
L
_i sq
. \ ('l k g TER EQUIPMENT ITEM NO. 54 Soleno; Valve Located in the Pipe Chase Plant ID: 2B21-A0V F077A,B ASCO Model NP8323A37E Service: Feedwater Check Valve Plant ID: 2B21-A0V F076A,B ASCO Model NP8323A37E Service: Feedwater Check Valve NRC DISCREPANCY Qualified Life or Replacement Schedule Established The licensee should establish a qualified life estimate based on actual operating temperatures (i.e. ambient plus heat rise) if normally energized and the available test data.
CLARIFICATION n
The manufacturer recommends replacement of non-metallic parts every four (4)
(. years based on the results of the Qualiilcation Tests. Georgia Power Company has established a qualified life of greater than four (4) years based on activation energies of the non-metallic materials obtained from ASCO, the aging test time and temperature, plant specific normal temperatures, and the Arrhenius equation. However, Gecrgia Power Company is following the manufacturers recommendations.
In accordance with the NRC recommendation, the replacement solenoid valves have
, been sealed at the conduit entrance with qualified materials which prevent moisture from entering the solenoid valve.
I
I l
r%
,~
TER EQUIPMENT ITEM NO. 64 Solenoid Valve Located Inside Coratinment Plant ID: 2B21-A0V F031A,C,E Target Rock Model 1/2 SMS-A-01-1 Service: Automatic Depressurization System NRC DISCREPANCY Qualified Life or R2 placement Schedule Established Criteria Regarding Aging Simulation Satisfied.
- 1. The Licensee references the aging analysis performed by Target Rock as Appendix I of TRC 2063B as evidence of qualification for a 5 year replacement interval for this equipment. It is noted, however, that the test report summary did not present cny eviderce that the thermal aging time and tempert.ture exposure was performed during the test progrr.m.
- 2. The radiation criteria has not been met. A conservative qualified life estimate dictated by the Licensee's plant specific application aging analysis (provided the thermal aging of Appendix I mentioned above was
, p g 3 performed) should alleviate this problem by reducing the radiation absorbed during normal life.
V -
CLARIFICATION The Target Rock Test Report provides a list of the non-metallic materials in the solenoid valve, of which there are two (2): Polyimide and Silicon Kubber.
The solenoid valves were aged for 480 hours0.00556 days <br />0.133 hours <br />7.936508e-4 weeks <br />1.8264e-4 months <br /> @ 285* F which was based on the 10' C rule. (The calculation is shown in Appendix I of the Test Report.) Georgia Pcwer Company has performed calculations using the above test data, plant specific temperatures, and the Arrehenius Equation to demonstrate a qualified life of 10 years for the silicon rubber 0-rings and gasket and 60 years for the polyimide.
7 The soler.oid valves were exposed to 3.26 x 10 radsfuringtesting.7However, the plant specific total integrated dose rads (1.8 x 10 rads for 40yearsofnormaloperationand2.6x10{s4.4x10 rads for accident dose).
The radiation threshold of silicon rubber is less than 4.4 x 10 rads, 7
tharefore, the silicon rubber shall not be exposed to more than 3.26 x 10 rads.
Georgia Power Company has performed a calculation which demonstrates that replacing the 0-ring 9 every ten (10) years will keep the total integrated dose less than 3.26 x 10' rads.
q Based on che above, Georgia Power Company has established a qualified life based on methods acceptable to the HRC.
m
l
[
U TER FQUIPMENT ITEM NO. 70 .
Limit Switches located in the Northeast Corner Room Plant ID: 2G51-F013 NAMCO Hodel EA740-20000/EA740-20100 Service: Torus Water Clean-up Isolation NRC DISCREPAMCY Aging Degradation Evaluated Adequately Qualified Life or Replacement Schedule Established The report states " Heat aging. The heat aging test consisted of holding the unit suspended over water in a tank at a temperature of 200*F for 200 hours0.00231 days <br />0.0556 hours <br />3.306878e-4 weeks <br />7.61e-5 months <br />.+
+ Heat aging conditions were taken from ANSI Draft Standard N278.2.1 (Draft '
3, Rev. 0). The correlation between these conditions and the qualified life is not known.
The licensea has referred to an "estimatiot. of gralified life of EA740 Series Nuclear $ witch" dated 2/27/1980. This NAMCO Report provides an estimated qualified life of 4.0 years at 104*F, assuming an activation energy of 0.958 eV t i for the NBR gasket material. The SCEW sheet states that the specified ambient
\s_,/ temp. is 135'F. No estimation of qualified life at the specified sesvice temperature is provided.
CLARIFICATION The normal operating temperature for the limit switch on valve 2G51-A0V F013 is 104*F. Therefore, the estimation of qualified life provided by NAMCO is applicable to Plant Haten for these liuit switches.
NAMCO is in the process of increasing the qualified life of these switches by using a different gasket material. When testing is complete, Georgia Power Company will review the report and if acceptable, vill modify these limit switches.
In accordance with the MRC recommendation, the teplacement limit awitches have been saaled at the conduit entrance with qualified materials which prevent moisture from entering the limit switch.
Georgia Power Company cor.siders these limit switches qualifed. Therefore, justification for Continued Operation is not required.
f C
)
i l
l 1
I.
(
TER EQUIPMENT ITEM NO. 73 Limit Switches located in the Pipa Chase Plant ID: 2B21-F028A,B.C.D NAMCO Model EA740-80001/EA740-80100 Service: Main Steam Line Isolation NRC DISCREPANCY Aging Degradation Evaluated Adequately Qualified Lifa or Replacement Schedule Established The repoic states " Heat aging. The heat aging test consisted of holding the unit suspended over water in a tank at a temperature of 200*F for 200 hours0.00231 days <br />0.0556 hours <br />3.306878e-4 weeks <br />7.61e-5 months <br />.+
+ Heat aging conditions were taken from ANSI Draft Standard N278.2.1 (D aft 1, Rev. 0). The correlation between these conditions and the qualified life in not known.
The licensee has referred to an " estimation of gralified life of EA740 Series Nuclear Switch" dated 2/27/1980. This NAMCO Report provides an estimated qualified life of 4.0 years at 104*F, assuming an activation energy of 0.958 eV
[ } for the NBR gasket material. The SCEW sheet states that the specified ambient
( ,1 temp. is 135'F. No estimation of qualified life at the epecified service temperature is provided.
CLARIFICATIO_N_
Georgia Power Company has replaced these limit switches with upgraded limit switches of the same model but which are qualified per NAMCO Report QTR-111.
The qualification report provides a temperature versus time curve based on the test time and temperature and the Arrhenius equation. Georgia Power has established a qualified life for these switenes using this curve.
In accordance with the NRC recommendation, the replacement limit switches have been sealed at the conduit entrance with qualified materials which prevent moisture from e::tering the limit switch.
l 4
m
V TER EQUIPMENT ITEM NO. 74_
Limit Switches located in the Containment Plant ID: 2B21-A0V F022A,B.C.D NAMCO Model FA740-80100/EA740-80001 Service: Main Steam Line Isolation NRC DISCREPANCY Aging Degradation Evaluated Adequately Qualified Life or Replacement Schedule Established l
The report states " Heat aging. The heat aging test consisted of hc3 ding the unit suspended over water in a tank at a temperature of 200*F for 200 hours0.00231 days <br />0.0556 hours <br />3.306878e-4 weeks <br />7.61e-5 months <br />.+
+ Heat aging conditions .ere taken from ANSI Draft Standard N278.2.1 (Draft 3, Rev. 0). The correlaticn between these conditions and the qualified life is not known.
The licensee has referred to an " estimation of qualified life of EA740 Series Nuclear Switch" dated 2/27/1980. This NAMCO Report provides an estimated es qualified life of 4.0 years at 104*F, assuming an activation energy of 0.958 eV
[\s_,/
T for the NBR gasket material. The SCEW rheet states that the specified ambient temp. is 135*F. No estimation of qualified life at the specified service temperature is provided.
CLARIFICATION Georgia Power Company has replaced these limit switches with upgraded limit switches of the same model but which are qualified per NAMCO Report QTR-111.
The qualification report provides a temperature versus time curve based on the test time and temperature and the Arrhenius equation. Georgia Power has established a qualified life for these switches using this curve.
In accordance with the NRC recommendation, the replacement limit switches have been sealed at the conduit entracce with qualified materials which prevent moisture from entering the limit switch.
\
j
(
(
TER EQUIPMENT ITEM NO. 76 Limit Switches located in the Torus Room Plant ID: 2G51-A0V F011 NAMCO Model EA740-20000 Service: Torus Water Clean-up Isolation Valve Plant ID: 2G51-A0V F012 FAMCO Model EA740-20000 Service: Torus Water Clean-up Isolation Valve NRC DISCREPANCY Aging Degradation Evaluated Adequately Qualified Life or Replacement Schedule Established The report states " Heat aging. The heat aging test consisted of holding the unit suspended over water in a tank at a temperature of 200*F for 200 hours0.00231 days <br />0.0556 hours <br />3.306878e-4 weeks <br />7.61e-5 months <br />.+
+ Heat aging conditions were taken from ANSI Draft Standard N278.2.1 (Draft 3, Rev. 0). The correlation between these conditions and the qualified life is not known.
V '
The licensee has referred to an " estimation of qualified life of EA740 Series Nuclear Switch" dated 2/27/1980. This NAMCO Report provides an estimated qualified life of 4.0 years at 104*F, assuming an activation energy of 0.958 eV for the NBR gasket material. The SCEW sheet states that the specified ambient temp. is 135'F. No estimation of qualified life at the specified service temperature is provided.
CLARIFICATION The normal operating temperature for the limit switch on valves 2G51-A0V F011 and F012 is 104*F. Therefore, the estimation of qualified life provided by NAMCO is applicable to Plant Hatch for these linit switches.
NAMCO is in the process of increasing the qualified life of these switches by using a different gasket material. When testing is complete, Ceorgia Power Company will review the report and if acceptable, will modify these limit switches.
In accordance with the NRC recommendation, the replacement limit switches have been sealed at the conduit entrance with qualified materials which prevent moisture from entering the limit switch.
Georgia Power Company censiders these limit switches qualified. Therefore, justification for Continued Operation is not required.
1 TER EQUIPMENT ITEM NO. 80 ,
Limit Switches located in the Torus Room l Plant ID: 2G11-F003 NAMCC Model EA18034302 Service: Drywell Floor Drain Pump Isolation Valve Plant ID: 2G11-F004 NAMCO Model EA18034302 Service: Drywell Floor Drain Pump Isolation Valve Plant ID: 2G11-F019 NAMCO Model EA18034302 Service: Drywell Equipment Drain Pump Isolation Valve Plant ID: 2G11-F020 NAMCO Model EA18034302 Service: Drywell Equipment Drain Pump Isolation Valve Plant ID: 2T48-F212 NAMCO Model EA18034302 Service: Drywell-Torus DP System
(' Plant ID: 2T48-F209 NAMCO Model EA18034302 Service: Drywell-Torus DP System Plant ID: 2T48-A0V F210 NAMCO Model EA18034302 Service: Drywell-Torus DP System Plant ID: 2T48-A0V F211 NAMCO Model EA18034302 Service: Drywell-Torus DP System NRC DISCREPANCY Aging Degradation Evaluated Adequately Qualified Life or Replacement Schedule Established The report states " Heat aging. The heat aging test consisted of holding the unit suspended over water in a tank at a temperature of 200*F for 200 hours0.00231 days <br />0.0556 hours <br />3.306878e-4 weeks <br />7.61e-5 months <br />.+
+ Heat aging conditions were taken from ANSI Draft Standard N278.2.1 (Draft
- 3. Rev. 0). The correlation between these conditions and the qualified life is not known.
O b
O)
TER EQU1PMENT ITEM NO. 80 (Continued)
The licensee has referred to an " estimation of qualified life of EA740 Series Nuclear Switch" dated 2/27/1980. This NAMCO Report provides an estimated qualified life of 4.0 years at 104'F, assuming an activation energy of 0.958 eV for the NBR gasket material. The SCEW sheet states that the.specified ambient temp. is 135'F. No estimation of qualified life at the specified service temperature is provided.
CLARIFICATION Georgia Power Company has replaced these limit switches with upgraded limit switches of the same model but which are qualified per NAMCO Report QTR-105.
The qualification report provides a temperature versus time curve based on the test time and temperature and the Arrhenius equation. Georgia Power has established a qualified life for these switches using this curve.
In accordance with the NRC recommendation, the replacement limit switches have been sealed at the conduit entrance with qualified materials which prevent moisture from entering the limit switch.
[G -
l t i v
l
O TER EQUIPMENT ITEM NO. 188 Motorized Valve Actuator Located in the Pipe Penetration Room Plant ID: 2 Ell-MOV F015A,B Limitorque Model SMB, AC Service, Class RH Insulation Service: LPCI Discharge Valve NRC DISCREPANCY Aging Degradation Evaluated Adequately Qualified Life or Replacement Scheduled Established A. The licensee has not provided documented evidence from the manufacturer that the installed equipment and the test specimen (s) in the referenced report (s) are similar. The licensee has identified only two motorized valve actuators that incorporates a motor-brake assembly, yet has reference
, several reports which tested motorized valve actuators equipped with such devices. The licensee should obtain the information necessary to establish similarity, or submit the same if it is already in their central file (also referencing this information on the System Component Evaluation Worksheets
.(SCEWs)).
B. The lit.ensee has cited B0058 for many equipment items in an effort to establish similarity between the installed and tested equipment. It should be noted that Limitorque's generic qualification program is acce'ptable, but that this report does not in itself establish similarity, nor does it l establish a qualified life estimate for this equipment. In order to establish a qualified life estimate for this equipment, the licensee must completely identify the installed components (i.e. motor lead insulation, type of torque switch) and then calculate a qualified life based on available information. This available information can come from either testing performed prior to environmental testing or from published data.
None of the referenced reports have calculated a qualified life estimate based on an acceptable technique. It should also be noted that the thermal aging that has been performed has been done on individual components or simulates only a fraction of the qualified life claimed. No basis has been stated on the report (s) for the times or temperatures chosen for the thermal aging performed. Particular attention should be given to the motor-brake assembly (if any) and the motor lead insulation where Teflon 3
has been used in some cases.
CLARIFICATION Documented evidence establishing similarity between the installed equipment and the test specimen is provided by the manufacturer and can be found in Georgia Power Company's Qualification Documentation Files.
] w
}
TER EQUIPMENT ITEM NO. 188 (Continued)
Additionally, FRC states that a qualified life has not been established in an acceptable manner. The DOR Guidelines do not require a qualified life to be established for all equipment.
Georgia Power Company has performed further evaluation of age sensitive components and, using available test data and published data, established a qualified life in accordance with the requirements of the DOR Guidelines.
Therefore, this equipment is considered qualified and Justification for 1 Continued Operation is not required.
s -
SECTION D OPEN ITDi EQUIPMENT LIST INTRODUCTION This section provides, per the requirements of 10CFR50.49, Paragraph (g), a list of electrical equipment important to safety, which has not yet been
- environmentally qualified by Georgia Power Company.
The equipment is identified by the TER Equipment Item Number (if applicable) and associated Plant Identification Number, followed by the Equipment Lccation, Equipment Description, and the Equipment Service.
The Corrective Action for resolving the Open Item and a schedule for completing that action is provided for the equipmca;.
The schedules provided for resolving the open items meet the requirements of 10CFR50.49, Paragraph (g).
O v
i O
,.,-.--.,--,---m
]
TABLE D-1 OPEN ITEM EQUIPMENT LIST TER EQUIPMENT ITEM NO. 5 Plant ID: 2E11-MOV F016B Motorized Valve Actuator Located in the RWCU HX Room Limitorque Model EMB, AC Service, Class B Insulation Service: Containment Spray Discharge Isolation Valve
_C_0RRECTIVE ACTION: The actuator and motor for chis motor operated valve will be ,
replaced with a qualified actuator and motor prior to or during the Unit 2, 1984 l Refueling Outage. '
TER EQUIPMENT ITEM NO. 6 Plant ID: 2E51-MOV F031 Motorized Valve Actuator Located in the RCIC (Northwest) Corner Room Limitorque Model SMB, DC Service, Class B Insulation Service: RCIC Pump Suction Valve from Suppression Pool CORRECTIVE ACTION: The motor for this motor operated valve vill be replaced with a qualified motor prior to or during the Unit 2, 1984 Refueling Outage, a 1 MV b75B Motyrized Valve Actuator Located in the Tcrus Room Limitorque Model SMB, AC Service, Class F Insulation Service. RHR Service Water Pump Discharge Valve CORFECTIVE ACTION: The motor for this noter operated valve will be replaced with a qualified motor prior to or during the Unit 2, 1983 Refueling Outage.
TER TQUIPHENT ITEM NO. 8 Plan: ID: 2E11-MOV F027A Motorized Valve Actuator Located in the Torus Room Limiterque Model SMB, AC Service Service: Suppression Pool Spray Valve CORRECTIVE ACTION: The motor for this motor operated valve will be replaced with a qualified motor prior to or during the Unit 2, 1983 Refueling Outage.
TER EQUIPMENT ITEM NO. 10 Plant ID: 2E51-MOV F013 Motorized Valve Actuator Located in the Terus Room Limitorque Model SMB, DC Service, Class B Insulation Service: RCIC Pump Inbcard Discharge Valve CORRECTIVE ACTICit: The notor for this motor operated valve will be replaced with a qualified motor prior to or during the Unit 2, 1983 Refueling Outage.
,e--
/
TER EQUIPMENT ITEM NO. 11 Plant ID: 2E21-MOV F004B Motorized Valve Actuator Located in the RWCU HX Room Limitorque Model SMB, AC Service, Class H Insulation Service: Core Spray Outboard Valve CORRECTIVE ACTION: The actuator and motor for this motor operated valve will be replaced with a qualified actuator and motor prior to or during the Unit 2, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO. 11 Plant ID: 2E21-MOV F004A Motorized Valve Actuator located in the Reactor Building Elev.158'0" Limitorque Model SMB, AC Service, Class H Insulation Service: Core Spray Outboard Valve CORRECTIVE ACTION: The actuator and motor for this motor operated v.11ve will be replaced with a qualified act.uator and motor prior to or during the Unit 2,1984 Refueling Outage.
TER EQUIPMENT ITEM NO. 16 Plant ID: 2E21-MOV F005B Motorized Valve Actuator Located in the RWCU liX Room
\ Limitorque Model SMB, AC Service, Class RH Insulation
_, ) Service: Core Spray Inboard Valve ,
CORRECTIVE ACTION: The actuator and motor for this motor operated valve will be replaced with a qualified actuator and motor prior to or during the Unit 2, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO. 16 Plant ID: 2E21-MOV F005A Motorized Valve Actuator Located in the Reactor Building, Elev. 158'0" Limitorque Model SMB, AC Service, Class RH Insulation Service: Core Spray Inboard Valve CORRECTIVE ACTION: The actuator and motor for this motor operated valve will be replaced with a qualifica actuator and motor prior to or durin3 the Unit 2, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO. 20 Plant ID: 2E11-MOV F008 Motorized Valve Actuator Located in the Torus and Pipe Penetration Rooms Limitorque Model SMB, DC Service, Class B Insulation Service: Shutdown Cooling Suction Isolation CORRECTIVE ACTION: The actuator and motor for this motor operated valve will be replaced with a qualified actuator and motor prior to or during the Unit 2, 1984 Refueling Outage.
e
O TER EQUIPMENT ITEM NO. 20 Plant ID: 2E41-MOV F006 Motorized Valve Actuator Located in the Torus and Pipe Penetration Rooms Limitorque Model SMB, DC Service, Class B Insulation Service: HPCI Pump Inboard Discharge Valve CORRECTIVE ACTION: The actuator and motor for this motor operated valve will be replaced with a qualified actuator and motor prior to or during the Unit 2, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO. 21 Plant ID: 2E11-MOV F003A Motorized Valve Actuator Located in the Northeast & Southeast Corner Rooms Limitorque Model SMB, AC Service, Class F Insulation Service: HI Discharge CORRECTIVE ACTION: The motor for this motor operated valve will be replaced with a qualified motor prior to or during the Unit 2, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO. 21 Plant ID: 2E11-MOV F021B Motorized Valve Actuator Located in the RWCU Hx Room
()
Limitorque Model SMB, AC Service, Class F Insulation Service: Containment Spray Discharge Valve CORRECTIVE ACTION: The actuator and motor for this motor operated valve will be replaced with a qualified actuator and motor prior to or during the Unit 2, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO. 22 Plant ID: 2E41-MOV F008 Motorized Valve Actuator Located in the HPCI Room Limitorque Model SMB, DC Service, Class B Insulation Service: Test Bypass Valve to Condensate Storage CORRECTIVE ACTION: The actuator and motor for this motor operated valve will be replaced with a qualified actuator and motor prior to or during the Unit 2, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO. 22 Plant ID: 2E41-MOV F004 Motorized Valve Actuator Located in the HPCI Room Limitorque Model SMB, DC Service, Class B Insulation Service: Pump Suction from Condensate Storage Tank CORRECTIVE ACTION: The motor for this motor operated valve will be replaced with a qualified motor prior to or during the Unit 2, 1984 Refueling Outage.
O
\
/
TER EQUIPMENT ITEM NO. 22 Plant ID: 2E41-MOV F042 Motorized Valve Actuator Located in the HPCI Room Limitorque Model SMB, DC Service, Class B Insulation Service: Pump Suction from Suppression Pool ,
CORRECTIVE ACTION: The motor for this motor operated valve will be replaced with a qualified motor prior to or during the Unit 2, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO. 25 Plant ID: 2 Ell-MOV F016A Motorized Valve Actuator Located in the Pipe Penetration Room Limitorque Model SMB, AC Service, Class B Insulation Service: Containment Spray Discharge Valve CORRECTIVE ACTION: The actuator and motor for this motor operated valve will be replaced with a qualified actuator and motor prior to or during the Unit 2, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO. 25 Plant ID: 2 Ell-MOV F021A Motorized Valve Actuator Located in the Pipe Penetration Room Limitorque Model SMB, AC Service, Class B Insulatien Service: Containment Spray Discharge Valve CORRECTIVE ACTION: The actuator and motor for this motor operated va'ive will be replaced with a qualified actuator and motor prior to or during the Unit 2, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO. 30 Plant ID: 2B31-MOV F031A.B Motorized Valve Actuator Located in the Containment Limitorque Model SMB, AC Service, Class H Insulation Service: Recirculation Pump Discharge Isolation CORRECTIVE ACTION: The actuator and motor for this motor operated valve will be replaced with a qualified actuator and motor prior to or during the Unit 2, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO. 32 Plant ID: 2E41-MOV F012 Motorized Valve Actuator Located in the HPCI Room Limitorque Model SMB, DC Service Service: Minimum Flow Bypass CORRECTIVE ACTION: The actuator and motor for this motor operated valve will be replaced with a qualified actuator and motor prior to or during the Unit 2, 1984 Refueling Outage.
m n
\
TER EQUIPMENT ITEM NO. 32 Plant ID: 2E41-MOV F011 Motorized Valve Actuator Located in the HPCI Room Limitorque Model SMB, DC Service Service: Test Bypass Valva to Condensate Storage CORRECTIVE ACTION: The actuator and motor for this motor operated valve will be replaced with a qualified actuator and motor prior to or during the Unit 2, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO. 91 Plant ID: 2T48-DPS N210 D/P Switch Located in the Reactor Building, Elev. 130'0" Static-0-Ring Model 22R3K614CIAPP Service: Torus to ATM Hi DP CORRECTIVE ACTION: The switch will be replaced with a qualified Rosemount Type 1153 transmitter and a Foxboro trip card (located in the Main Control room) during the Unit 2, 1984 Refueling Outage.
TFR EQUIPMENT ITEM NO. 91 Plant ID: 2T48-DPS N211 gg D/P Switch Located in the Reactor Building Elev. 130'0"
( ) Static-0-Ring Model 22R3K614CITX3
\s,,/ Service: Torus to ATM Hi DP -
CORRECTIVE ACTION: The switch will be replaced with a qualified Rosemount Type 1153 transmitter and a Foxboro trip card (located in the Main Control room) during the Unit 2, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO. 92 Plant ID: 2E41-DPIS N005 D/P Switch Located in the Reactor Building, Elev. 130'0" Barton Model 288 Service: HPCI Steam Line Hi Differential Press CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 2, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO. 92 Plant ID: 2E41-DPIS N004 D/P Switch Located in the Reactor Building, Elev. 130'0" Barton Model 288 Service: HPCI Steam Line Hi Differential Press CORRECTIVE ACTION: The switch will be replaced with a qualified Barton
['~') transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the
\~/
1 Unit 2, 1984 Refueling Outage.
D TER EQUIPMENT ITEM NO. 93 Plant ID: 2E41-FS N006 Flow Switch Located in the HPCI Room Barton Model 289 Service: HPCI Pump Discharge H1/ Low Flow CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 2, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO. 94 Plant ID: 2E21-FIS N006A,B Flow Switch Located in the Northeast & Southeast Corner Rooms Barton Model 289 Service: Pumps Outlet Flow CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 2, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO. 95 Plant ID: 2E41-LS N015A,B
( _
Level Switch Located in the Torus Rocm ,
Magnetrol Model 35751 MPG Service: Suppression Pool Hi Level Signal to Open Valve CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 2, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO. 96 Plant ID: 2B21-LIS N042A,B Level Indicating Switch Located in the Reactor Building, Elev. 158'0" Yarway Model 4418C Service: Auto. Blowdown Permissive CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 2, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO. 96 Plant ID: 2B21-LIS NO31A,B,C,D Level Indicating Switch Located in the Reactor Building, Elev. 158'0" Yarway Model 4418C Service: Init. RCIC HPCI & RHR Sys.
Ns-CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 2, 1984 Refueling Outage.
, TER EQUIPMENT ITEM NO. 97 i
Plant ID: 2B21-LITS NO37 Level Indicating Switch Located in the Reactor Building. Elev. 130'0" ,
1 Yarway Model 4418CE t Service: Shroud Level-RHR Interlock CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior tc. or during the Unit 2 1984 Refueling Outage.
TER EQUIPMENT ITEM NO. 98 Plant ID: 2B21-LITS NO36 Level Indicating Switch Located in the Reactor Building, Elev. 130'0" Yarway Model 4418CE Service: Shroud Level-RHR Interlock CORRECTIVE ACTION: The switch will be replaced with a qualified Barton
. transmitter and a qualified General Electric trip unit as part of the Analog Trant: sitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 2, 1984 Refueling Outage.
n 2-LSNb17,BC.D
.(') Level Indicating Switch Located in the Reactor Building, Elev. 158'0"'
Barton Model 288A Service; Trip RCIC & HPCI Turbine CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 2, 1984 Refueling Outage.
I TER EQUIPMENT ITEM NO. 101 Plant ID: 2E11-PS N010A,B.C.D Pressure Switch Located in the Reactor Building, Elev. 158'0" i Barksdale Model D2HM18SS Service: Auto Initiating Hi Drywell Press.
l CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog i- Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 2, 1984 Refueling Outage.
1 p
r I
- .. - - - - . .- .. ..-.-. .. _ . : - . . . . _ . - . ~ . . - . . . . . - . , _ . - , , - _ - - , _ _ - .-
O TER EQUIPMENT ITEM NO. 101 Plant ID: 2 Ell-PS N011A,B,C.D Pressure Switch Located in the Reactor Building, Elev. 158'0" Barksdale Model D2HM18SS Service: Auto Initiating Hi Drywell. Press.
CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trio unit as part of the Analog Transtitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 2, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO. 102 Plant ID: 2C71-PS N002A,B C.D Pressure Switch Located in the Reactor Building, Elev. 158'0" Barksdale Model D2HM18SS Service: Primary Containment Hi Pressure Switch CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog a Transmitter Trip System (ATTS). ATTS will be installed prior to or d r ing the Unit 2, 1984 Refueling Outage. .
TER EQUIPMENT ITEM NO. 103 Plant ID: 2E51-PS N012A,B.C.D Pressure Switch Located in the RCIC (Northwest) Corner Room Barksdale Model D2HM80SS Service: Turbine Exhaust Diaphragm 1
CCRRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog
- Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 2, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO. 104 Plant ID: 2E21-PS N009A,B Pressure Switch Located in the Northeast and Southeast Corner Rooms Barksdale Model B2IM12SS Service: Core Spray Pump Outlet Pressure CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 2, 1984 Refueling Outage.
O E __- ._ _ _ __ ___ _ _ _ - _ _ _
c O
TER EQUIPMENT ITEM NO. 104 Plant ID: 2E21-PS N008A,B ,
Pressure Switch Located in the Northeast and Southeast Corner Rooms Barksdale Model B2TM12SS Service: Core Spray Pump Outlet Pressure CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 2, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO. 104 Plant ID: 2E11-PS N020A,B,C,D Pressure Switch Located in the Northeast and Southeast Corner Rocas Barksdale Model B2TM12SS Service: RHR Pump Discharge Pressure CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 2, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO. 104 Plant ID: 2E11-PS N016A,B,C.D
,/ P ressure Switch Located in the Northeast and Southeast Corner Rooms l Barksdale Model B2TM12SS Service: RHR Pump Discharge Pressure CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog l Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 2, 1984 Refueling Outage.
l TER EQUIPMENT ITEM NO. 105 l Plant ID: 2E41-PS N001A,B,C D l Pressure Switch Located in the Reactor Building, Elev. 130'0" l Barksdale Model B2TM12SS Service: HPCI Low Pressure Isolation Signal CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit es part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 2, 1984 Refueling Octage.
, .(_l
I TER EQUIPMENT ITEM NO. 105 1 Plant ID: 2E51-PS N019A,B,C.D 1 i Pressure Svitch Located in the Reactor Building, 21ev. 130'0" ,
Barksdale Model B2TM12SS '
l Service: RCIC Steam Header Pressure Low !
CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 2, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO. 105 Plant ID: 2B21-PS N021D,F Pressure Switch Locatad in the Reactor Building, Elev. 130'0"
. Barksdale Model B2TM12SS Service: Cora Spray & RHR Valve OP Perm.
CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Tran:nitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 2, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO. 108 Plant ID: 2E41-PS N012A,B.C.D Pressurr Switch Located in the HPCI Room i k s_^ Barksdale Model D2HM150SS I
) Service: HPCI Turbine Exhaust Hi Pressure i
CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 2, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO. 109 Plant ID: 2E41-PS N010 Pressure Switch Located in the HPCI Room Static-0-Ring Model 6NAA21X9VSTT Service: HPCI Pump Suction Pressure Low CORRECTIVE ACTION: The switch will *oe replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 2, 1984 Refueling Outage.
TER EQUIPMENI ITEM NO. 110 Plant ID: 2B21-PS N021A E Pressure Switch Located in ttc Reactor Building, Elev. 158'0" Barksdale Model B2TM12SS Service: Cort. Spray and RHR Valve OP Perm.
%- CORRECTIVE ACTION: The switch will be replaced with a goalified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 2, 1984 Refueling Outage.
_ f
t L) TER EQUIPMENT ITEM NO. 112 Plant ID: 2E41-PS N017A B Pressure Switch Located in the HPCI Room Barksdale Model B2TM12SS Service: HPCI Turbine Exh. Hi Pressure Trip CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 2, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO. 112 Plant ID: 2E41-PS N027 Pressure Switch Located in the HPCI Room Barksdale Model B2TM12SS Service: HPCI Pump Discharge Pressure CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 2, 1984 Refueling Outage.
TER EOUIPMENT ITEM NO. 113
['~'\ Plant ID: 2B21-TS N010A,B,C,D
\_) Temperature Switch Located in the Pipe Chase Fenwall Model 1700240 Service: Main Steam Line Leak Detection CORRECTIVE ACTIONi The temperture switch will be replaced with a qualified Weed temperature element and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 2, 1984 Refueling Outage, l
i TER EQUIPMENT ITEM NO. 113 l Plant ID: 2B21-TS N011A,B C.D l Temperature Switch Located in the Pipe Chase l Fenwall Hodel 1700240
! Service: Main Steam Line Leak Detection
! CORRECTIVE ACTION: The temperture switch will be replaced with a qualified Wec.d l temperature element and a qualified General Electric trip unit as part of the
! Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or j during the Unit 2, 1984 Refueling Outage.
i l
v
v TER EQUIPMENT ITEM NO. 113 i
Plant ID: 2B21-TS N012A,B,C,D Temperature Switch Located in the Pipe Chase Fenwall Model 1700240 1 Service: Main Steam Line Leak Detection I
CORRECTIVE ACTION: The temperature switch will be replaced with a qualified Weed temperature element and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 2, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO. 113 Plant ID: 2B21-TS N013A,B C,D Temperature Switch Located in the Pipe Chase Fenwall Model 1700240 Service: Main Steam Line Leak Detection CORRECTIVE ACTION: The temperature switch will be replaced with a qualified Weed temperature element and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or
- during the Unit 2, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO. 114 Plant ID: 2E41-TE NO30A,B x
Temperature Element Located in the HPCI Room ,
PYC0 Model N145C3224P1 Type T Thermocouple Service: HPCI Area Leak' Detection CORRECTIVE ACTION: The temperature element will be replaced with a qualified Weed temperature element as part of the Analog Transmitter Trip System (ATTS).
ATTS will be installed prior to or during the Unit 2, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO. 115 Plant ID: 2E41-TE N046A,B Temperature Element Located in the Pipe Penetration Room PYC0 Model N145C3224P1 Type T Thermocouple Service: HPCI Steam Leak Detection CORRECTIVE ACTION: The temperature element will be replaced with a qualified Weed temperature element as part of the Analog Transmitter Trip System (ATTS).
ATTS will be installed prior to or during the Unit 2, 1984 Refueling Outage.
j TER EQUIPMENT ITEM NO. 116 Plant ID: 2E51-TE N023A,B Temperature Element Located in the RCIC (NW) Corner Room PYC0 Model N145C3224P1 Type T Thermocouple Service: RCIC Area Steam Leak Detection i CORRECTIVE ACTION: The temperature element will be replaced with a qualified -
j Weed temperature element as part of the Analog Transmitter Trip System (ATTS).
N- ATTS will be installed prior to or during the Unit 2, 1984 Refueling Outage.
I we ,e e---w e - , . v p <- - w w m-w w- m -- ow n ,-,-e,~ ~w-w,m--,,--~,-, mew-- -rw~, --wn ,- e w -w,---- v,-*e-m ------,---w--w-,, -w --- ------
O TER EQUIPMENT ITEM NO. 116 Plant ID: 2E51-TE N022A,B Temperature Element Located in the RCIC (NW) Corner Room PYC0 Model N145C3224P1 Type T Thermocouple Service: RCIC Area Steam Leak Detection CORRECTIVE ACTION: The temperature element will be replaced with a qualified Weed temperature element as part of the Analog Transmitter Trip System (ATTS).
ATTS will be installed prior to or during the Unit 2, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO. 116 Plant ID: 2E51-TE N021A,B Temperature Element Located in the RCIC (NW) Corner Room PYC0 Model N145C3224P1 Type T Thermocouple Service: RCIC Area Steam Leak Detection CORRECTIVE ACTION: The temperature element will be replaced with a qualified Weed temperature element as part of the Analog Transmitter Trip System (ATTS).
ATTS will be installed prior to or during the Unit 2, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO. 117 Plant ID: 2E51-TE N026A,B.C.D Temperature Element Located in the Torus Room PYC0 Model N145C3224P1 Type T Thermocouple Service: RCIC Area Steam Leak Detection ,
CORRECTIVE ACTION: The temperature element will be replaced with a qualified Weed temperature element as part of the Analog Transmitter Trip System (ATTS).
ATTS will be installed prior to or during the Unit 2, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO. 117 Plant ID: 2E51-TE N027A,B,C,D Temperature Element Located in the Torus Room PYCO Model N145C3224P1 Type T Thermocouple Service: RCIC Area Steam Leak Detection CORRECTIVE ACTION: The temperature element will be replaced with a qualified Weed temperature element as part of the Analog Transmitter Trip System (ATTS).
ATTS will be installed prior to or during the Unit 2, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO. 117 Plant ID: 2E51-TE N025A,B C.D Temperature Element Located in the Torus Room PYCO Model N145C3224P1 Type T Thermocouple Service: RCIC Area Steam Leak Detection CORRECTIVE ACTION: The temperature element will be replaced with a qualified Weed temperature element as part of the Analog Transmitter Trip System (ATTS).
] ATTS will be installed prior to or during the Unit 2,1984 Refueling Outage.
O TER EQUIPMENT ITEM NO. 118 Plant ID: 2G31-TE N016C,D,E,F Temperature Element Located in the RWCU HX Roon PYC0 Model N145C3224P1 Type T Thermocouple Service: Clean-up System Leak Detection CORRECTIVE ACTION: The temperature element will be replaced with a qualified Weed temperature element as part of the Analog Transmitter Trip System (ATTS).
ATTS will be installed prior to or during the Unit 2,1984 Refueling Outage.
TER EQUIPMENT ITEM NO. 118 Plant ID: 2G31-TE N022A,B Temperature Element Located in the RWCU Pump Room PYC0 Model N145C3224P1 Type T Thermocouple Service: Clean-up System Leak Detection CORRECTIVE ACTION: The temperature element will be replaced with a qualified Weed temperature element as part of the Analog Transmitter Trip System (ATTS).
ATTS will be installed prior to or during the Unit 2, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO. 118 Plant ID: 2G31-TE N022C,D,E,F Temperature Element Located in the RWCU HK Room PYC0 Model N145C3224P1 Type T Thermocouple O Service: Clean-up System Leak Detection
- CORRECTIVE ACTION
- The temperature element will be replaced with a qualified Weed temperature element as part of the Analog Transmitter Trip System (ATTS).
ATTS will be installed prior to or during the Unit 2, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO. 118 Plant ID: 2G31-TE N023A,B,C Temperature Element Located in the Reactor Bulding, Elev. 158'0"
. PYC0 Model N145C3224P1 Type T Thermocouple Service: Clean-up System Leak Detection CORRECTIVE ACTION: The temperature element will be replaced with a qualified Weed temperature element as part of the Analog Transmitter Trip System (ATTS).
ATTS will be installed prior to or during the Unit 2,1984 Refueling Outage.
l TER EQUIPMENT ITEM NO. 118 i Plant ID: 2G31-TE N023D E Temperature Element Located in the RWCU HX Room PYC0 Model N145C3224P1 Type T Thermocouple i Service: Clean-up System Leak Detection CORRECTIVE ACTION: The temperature element will be replaced with a qualified Weed temperature element as part of the Analog Transmitter Trip System (ATTS).
ATTS will be installed prior to or during the Unit 2, 1984 Refueling Outage.
4
-- ,---,--,--,--,-,--n, - - , - - ..c., ,n---- - , - ,
t I
TER EQUIPMENT ITEM NO. 118 Plant ID: 2G31-TE NO23F Temperature Element Located in the Reactor Building, Elev. 185'0" PYC0 Model N145C3224P1 Type T Thermocouple
-l Services Clean-up System Leak Detection CORRECTIVE ACTION: The temperature element will be replaced with a qualified Weed temperature element as part of the Analog Transmitter Trip System (ATTS).
ATTS will be installed prior to or during the Unit 2,1984 Refueling Outage.
TER EQUIPMENT ITEM NO. 118
, Plant ID: 2G31-TE N016A,B Temperature Element Located in the RWCU Pump Room PYC0 Model N145C3224P1 Type T Thercocouple Service: Clean-up System Leak Detection 1
CORRECTIVE ACTION: The temperature element will be replaced with a qualified Weed temperature element as part of the Analog Transmitter Trip System (ATTS).
l.
s ATTS will be installed prior to or during the Unit 2,1984 Refueling Outage.
TER EQUIPMENT ITEM NO. 119 Plant ID: 2T48-TE N009A Temperature Element Located in the Torus Room Rosemount Model 885190
- Service: Torus Water Temperatere -
- CORRECTIVE ACTION
- The temperature element will be replaced by a qualified PYC0 temperature element during the Unit 2, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO. 120 Plant ID: 2T48-TE N009B.C Temperature Element Located in the Torus Room Rosemount Model 88136 Service: Torus Water Temperacure CORRECTIVE ACTION: The temperature element will be replaced by a qualified PYC0 temperature element during the Unit 2, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO. 120 Plant ID: 2T48-TE N075 Temperature Element Located-in the Torus Room Rosemount Model 88136 Service: Torus Water Temperature CORRECTIVE ACTION: The temperature elenent will be replaced by a qualified PYCO
~teeperature element during the Unit 2, 1984 Refueling Outage.
'\
\v TER EQUIPMENT ITEM NO. 121 Plant ID: 2T47-TE N001L Temperature Element Located in the Containment Rosemount Model 885217 Service: Containmen; Air Temperature CORRECTIVE ACTION: The temperature element will be replaced by a qualified PYC0 ternperature element during the Unit 2, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO. 121 Plant ID: 2T47-TE N007 Temperature Element Located in the Containment Rosemount Model 885217 Service: Containment Air Temperature CORRECTIVE ACTION: The temperature element will be replaced by a qualified PYC0 temperature element during the Unit 2, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO. 122 Plant ID: 2G31-FT NO36 Flow Transmitter Located in the Reactor Building, Elev. 158'0" General Electric Model 555111BCAA4WAK Service: HPCI Pump Discharge In. Flow
\g I CORRECTIVE ACTION: The transmitter will be replaced with a qualifie( Barton transmitter as part of the Analog transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 2, 1984, Refueling Outage.
TER EQUIPMENT ITP J0. 122 Plant ID: 2G31-Fi N012 Flow Transmitter Located in the Reactor Building, Elev. 158'0" General Electric Model 555111BCAA4WAK Service: Flow to Cond. & Waste Collection
, CORRECTIVE ACTION: The transmitter will be replaced with a qualified Barton transmitter as part of the Analog transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 2, 1984, Refueling Outage.
TER EQUIPMENT ITEM NO. 122 Plant ID: 2G31-FT N041 Flow Transmitter Located in the Reactor Building, Elev. 158'0" General Electric Model 555111BCAA4WAK l
Service: HPCI Pump Discharge Out Flow CORRECTIVE ACTION: The tr&nsmitter will be replaced with a qualified Barton transr.itter as part of the Analog transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 2, 1984, Refueling Outage.
b 1 . - - . - . -. -.- - .- __ - - _ _ -- - . - - __ . .. . - - - - . _ _ .
$1' ft & s Y#h>%f/ IMAGE EVALUATION f 64 1, TEST TARGET (MT-3) (([// gY ' ,$ @
6 kg 7
%'t /gf/
t?> %'*4 1.0 E2 M yljE4 i,i j m Ele d
'I.25 1.4 i.6
_ _ . _ l{.
I 4 150mm 4 6"
+< 4 +4%
- ?hhVh/f' w,,
'4<>%[h' v
m 4&
% s
- IMAGE EVALUATION (([/ j 6 , {?f4 ' f $
g f77 ; c/
pf TEST TARGET (MT-3)
+#+ <e%e l.0 9 2 UE lc al gu rm j,j E m EM l.8 1.25 1.4
{' l.6 4 150mm E'
6"
%% ++/4 05 b Q
~Y>,i;,
'%v>(b
(
TER EQUIPMENT ITEM NO. 123 Plant ID: 2E11-FT N015A,B Flow Transmitter Located in the Northeast & Southeast Corner Rooms Barton Model 368 Service: RRR Flow CORRECTIVE ACTION: The transmitter will be replaced with a qualified Barton transmitter as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 2, 1984, Refueling Outage.
TER EQUIPMENT ITEM NO. 124 Plant ID: 2E21-FT N003A.B Flow Transmitter Located in the Northeast & Southeast Corner Rooms GE/MAC Model 555111BDAA4WAL Service: Pumps Outlet Flow CORRECTIVE ACTION: The transmitter will be replaced with a qualified Barton transmitter as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 2, 1984, Refueling Outage.
l TER EQUIPMENT ITEM NO. 125 Plant ID: 2E32-FE N006B.F.K,P l Flow Element Located in the Torus Room l Ametek Model 103K16HC177 Service: Inboard System Leakage Flow ,
CORRECTIVE ACTION: The cabla and connector associated with the flow element will be replaced with a qualified cable and connector during the Unit 2, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO. 126 Plant ID: 2B21-LT N027 Level Transmitter Located in the Reactor Building, Elev. 158'0" GE/MAC 555111BDAA4WAJ Service: - Vessel Water Level (Wide Range) 1 l CORRECTIVE ACTION: The transmitter will be replaced with a qualified Barton transmitter as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 2, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO. 127 Plant ID: 2E32-PT N061B,F.K.P
! Pressure Transmitter Located in the Torus Room Rosemount Model 1151GP6A52T0003PB Service: Inboard Main Steam Line Pressure CORRECTIVE ACTION: The transmitter will be replaced with a qualified Barton l transmitter as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 2, 1984 Refueling Outage, s
-y-- - . . _ _ _ ,,_--_-._.--_,,_-...--__-,.--.-m._,._,...---.--,_ . - - - .
TER EQUIPMENT ITEM NO. 127 Plant ID: 2E32-PI N051B.F.K,P Pressure Transmitter Located in the Torus Room i Rosemount Model 1151GP6A52T0003PB Service: Main Steam Line Pressure CORRECTIVE ACTION: The transmitter will be replaced with a qualified Barton transmitter as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 2, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO. 128 Plant ID: 2B21-PT N051A,B Pressure Transmitter Located in the Reactor Building, Elev. 158'0" Bailey Meter Model 163C1292P004 Service: Reactor Pressure CORRECTIVE ACTION: The transmitter will be replaced with a qualified Barton transmitter as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 2, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO. 129 Plant ID: 2E41-FT N008 Flow Transmitter Located in the HPCI Room Bailey Meter Model 555111BDAA4WAL Service: Pump Discharge Flow Signal to Turbine ,
CORRECTIVE ACTION: The transmitter will be replaced with a qualified Barton transmitter as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 2, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO. 130 Plant ID: 2 Ell-DPT N002A,B D/P Transmitter Located in the Northeast and Southeast Corner Rooms Rosemount Model 1151DP7B22MB Service: HX-Shell to Tube CORRECTIVE ACTION: The transmitter will be replaced with a qualified Barton transmitter as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 2, 1984 Refueling Outage.
I TER EQUIPMENT ITEM NO. 132 Plant ID: 2E32-PT N060 Pressure Transmitter Located in the Reactor Building, Elev. 158'0" Rosemount Model 1151GP6A52T0003PB Service: Reactor Vessel Pressure Inboard CORRECTIVE ACTION: The transmitter will be replaced with a qualified Barton transmitter as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 2, 1584 Refueling Outage.
f TER EQUIPMENT ITEM NO. 132 Plant ID: 2E32-PT N058 Pressure Transmitter Located in the Reactor Building, Elev. 158'0" Rosemount Model 1151GP6A52T0003PB Service: Reactor Vessel Pressure Outboard CORRECTIVE ACTION: The transmitter will be replaced with a qualified Barton transmitter as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 2, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO. 132 Plant ID: 2E32-PT N050 Pressure Transmitter Located in the Reactor Building, Elev. 158'0" Rosemount Model 1151GP6A52T0003PB Service: Reactor Vessel Pressure Inboard CORRECTIVE ACTION: The transmitter will be replaced with a qualified Barton transmitter as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 2, 1984 Refueling Outage.
TER EQUIPMENT ITEM FO. 134 Plant ID: 2E41-C00I71 Electric Motor Located in the HPCI Room General Electric Model CD259AT e Service: Auxiliary Lube Oil Pump Motor ,
CORRECTIVE ACTION: an analysis, of the equipment associated with the HPCI turbine and required to mitigate the consequences of an accident, was performed to determine the ec.:Ipmefa for which qualification could be established.
Equipment, whose qualJfication can not be established, will be replaced or relocated during :14 Unit 2,1984 Refueling Outage.
TEP EQUIPMENT ITEM NO. 136 Plant ID: 2E41-C002-3 Electric Motor Located in the HPCI Room General Electric Model 1610ATC Service: Glano Seal Pump Motor CORRECTIVE ACTION: An analysis, of the equipment associated with the HPCI turbine and required to mitigate the consequences of an accident, was performed to determine the equipment for which qualification could be established.
Equipment, whose qualification can not be established, will be replaced or relocated during the Unit 2, 1984 Refueling Outage.
i
l TER EQUIPMENT ITEM NO. 137 Plant ID: 2E41-C002-2 i Electric Motor Located in the HPCI Room Reliance Electric Model 215AY Service: Condensate Vacuum Pump Motor
, CORRECTIVE ACTION: An analysis, of the equipment associated with the HPCI turbine and required to mitigate the consequences of an accident, was performed I
to determine the equipment for which qualification could be established.
Equipment, whose qualification can not be established, will be replaced or relocated during the Unit 2, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO. 139 Plant ID: 2E32-C001 Electric Motor Located in the Torus Room Siemans-Allis Model 2CH60421U Service: Inboard Leak Control Blower CORRECTIVE ACTION: Georgia Power Company has reviewed summaries of the qualification documentation and found them acceptable. Georgia Power Company has received the qualification documentation and will complete the review by June 10, 1983.
TER EQUIPMENT ITEM NO. 139 Plant ID: 2E32-C002A.E Electric Motor Located in the Torus Room Siemans-Allis Model 2CH60421U Service: Outboard Leak Control Blower l CORRECTIVE ACTION: Georgia Power Company has reviewed summaries of the
, qualification documentation and found them acceptable. Georgia Power Company has received qualification documentation and will complete the review by June 10, 1983.
TER EQUIPMENT ITEM NO. 142 Plant ID: 2P33-P001A,B Hydrogen-Oxygen Analyzer Located in the Reactor Building, Elev. 158'0" Comsip-Delphi Model H2CDIB561B6C/02CDIB6G1B6C Service: Primary Containment H2and 0 Analyzer 2 CORRECTIVE ACTION: The 2 H and 2
0 analyzer will be replaced with a qualified Comsip Type K-IV H2 ""d 02 analyzer during the Unit 2, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO. 151 Plant ID: 2E41-C002 Turbine Located in the HPCI Room Terry Model CCS Service: HPCI Turbine CORRECTIVE ACTION: An analysis, of the equipment associated with the HPCI Turbine and required to mitigate the consequences of an accident, was performed to determine the equipment for which qualification could be established.
Equipment, whose qualification can not be established, will be replaced or relocated during the Unit 2, 1984 Refueling Outage.
TER EQUIPMENT ITEM No. 153 Plant ID: Buchanan Phenolic Terminal Block Located Inside and Outside the Drywell Amerace Model 515,222 and 212 Service: Terminal Blocks CORRECTIVE ACTION: Georgia Power Company is in the process of obtaining Qualification Test Reports for Buchanan Terminal Blocks. Upon receipt of the test report Georgia Power Company will evaluate the test report against the plant specific parameters. The evaluation of these test reports will be
- completed by the Unit 2, 1984 Refueling Outage.
T TER EQUIPMENT ITEM NO. 181 ,
Plant ID: 2B21-LITS N026A,B Level Transmitter Switch Located in the Reactor Building, Elev. 158'0" Yarway Model 4418CE Service: Reactor Level - RCIC CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 2, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO. 182 Plant ID: 2B21-LIS N025A B Level Indicating Switch Located in the Reactor BJilding, Elev. 158'0" Yarway Model 4418C Service: SCRAM-Close Main Steam Isolation Valve CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 2, 1984 Refueling Outage.
l
TER EQUIPMENT ITEM NO. 182 Plant ID: 2B21-LIS N024A,B Level Indicating Switch Located in the Reactor Building, Elev. 158'0" Yarway Model 4418C Service: SCRAM-Close Main Steam Isolation Valve CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part ef the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 2, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO. 183 Plant ID: 2E11-DPIS N021A,B D/P Switch Located in the Northeast and Southeast Corner Rooms Barton Model 289 Service: Heat Exchanger Discharge Header CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 2, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO. 184 Plant ID: 2E51-DPIS N017 D/P Switch Located in the Reactor Building, Elev. 130'0" ,
Barton Model 288 Service: RCIC Steam Line Hi Diff. Press.
CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the j Unit 2, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO. 184 Plant ID: 2E51-DPIS N018 D/P Switch Located in the Reactor Building, Elev. 130'0" Barton Model 288 Service: RCIC Steam Line Hi Diff. Press.
i CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 2, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO. 185 Plant ID: 2B21-DPIS N009A.B.C.D D/P Switch Located in the Reactor Building, Elev. 130'0"
! Barton Model 288 Service: Main Steam Flow Indicating Switch l
CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 2, 1984 Refueling Outage.
i
TER EQUIPMENT ITEM No. 185 Plant ID: 2B21-DPIS N008A,B.C.D D/P Switch Located in the Reactor Building, Elev. 130'0" Barton Model 288 Service: Main Steam Flow Indicating Switch CORRECTIVE ACTION: The switch will be r2placed with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 2, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO. 185 Plant ID: 2B21-DPIS N007A,B,C.D D/P Switch Located in the Reactor Building, Elev. 130'0" Barton Model 288 Service: Main Steam Flow Indicating Switch CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 2, 1984 Refueling Outage.
TER EQUIPMENT ITEM No. 185 Plant ID: 2B21-DPIS N006A,B.C.D D/P Switch Located in the Reactor Building, E12v. 130'0" ,
Barton Model 288 Service: Main Steam Flow Indicating Switch CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 2, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO.186 Plant ID: 2B21-PS N021C Pressure Switch Located in the Reactor Building, Elev. 130'0"
- Barton Model 288 Service
- Core Spray and RHR Valve OP Perm.
CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 2, 1984 Refueling Outage.
4 i
e
l TER EQUIPMENT ITEM NO. 186 Plant ID: 2B21-PS N021B Pressure Switch Located in the Reactor Building, Elev. 158'0" Barton Model 288 Service: Core Spray and RER Valve OP Perm.
CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 2, 1984 Refueling Outage.
TER EQUIPMENT ITEM NO. 190 Plant ID: 2E32-MOV F002B,F,K,P Motorized Valve Actuator Located in the Pipe Chase Limitorque Model SMB, AC Service, Class B Insulation Service: Main Steam Line Leakage Control Isolation Valve CORRECTIVE ACTION: The motor for this motor operated valve will be replaced with a qualified motor prior to or during the Unit 2, 1983 Refueling Outage.
TER EQUIPMENT ITEM NO. 190 Plant ID: 2E32-MOV F009 Motorized Valve Actuator Located in the Pipe Chase Limitorque Model SMB, AC Service, Class B Insulation Service: Main Steam Line Leakage Control Isolation Valve l
CORRECTIVE ACTION: The motor for this motor operated valve will be replaced with a qualified motor prior to or during the Unit 2, 1983 Refueling Outage.
TER EQUIPMENT ITEM NO. 190 Plant ID: 2E32-MOV F008 l Motorized Valve Actuator Located in the Pipe Chase Limitorque Model SMB, AC Service, Class B Insulation Service: Main Steam Line Leakage Control Isolation Valve CORRECTIVE ACTION: The motor for this motor operated valve will be replaced with a qualified motor prior to or during the Unit 2, 1983 Refueling Outage.
TER EQUIPMENT ITEM NO. 190 l
Plant ID: 2E32-MOV F007 Motorized Valve Actuator Located in the Pipe Chase Limitorque Model SMB, AC Service, Class B Insulation Service: Main Steam Line Leakage Control Isolation Valve CORRECTIVE ACTION: The motor for this motor operated valve will be replaced with a qualified motor prior to or during the Unit 2, 1983 Refueling Outage.
l
t TER EQUIPMENT ITEM NO. 190 Plant ID: 2E32-MOV F006 Motorized Valve Actuator Located in the Pipe Chase Limitorque Model SMB, AC Service, Class B Insulation Service: Main Steam Line Leakage Control Isolation Valve CORRECTIVE ACTION: The motor for this motor operated valve will be replaced with a qualified motor prior to or during the Unit 2, 1984 Refueling Outage.
l l
l l
l l
l
I The following equipment was not addressed in Franklin Research Center's Technical Evaluation Report. However, the equipment is part of Georgia Power Company's I.E. Bulletin 79-01B Open Item Equipment List.
Plant ID: 2PS2-PS N002 Pressure Suitch Located in the Reactor Building, Elev. 130'0" Static-O-Ring Model 6V2-EE5-CGGTTX5 Service: Non-Interruptible CORRECTIVE ACTION: The transmitter will replaced with a qualified Rosemount Type 1153 transmitter during the Unit 2, 1984 Refueling Outage. Justification for Continued Operation for this item has been previously submitted to the NRC in Georgia Power Company's response to NRC 1. E. Bulletin 79-01B - Environmental Qualification of Class 1E Equipment, Revision 4, dated January 8, 1982 for Edwin I. Hatch Nuclear Plant - Unit 2. The Justification can be found in Section B.3.1.1, on Page 19 and is still applicable.
Plant ID: 2B31-PS-N018A,B Pressure Switch Located in the Reactor Building Elev. 130' 0" Barksdale Model B2T-M12SS Service: Recirculation Suction Pressure.
CORRECTIVE ACTION: The switch will be replaced with a qualified Barton transmitter and a qualified General Electric trip unit as part of the Analog Transmitter Trip System (ATTS). ATTS will be installed prior to or during the Unit 2, 1984 Refueling Outage. Justification for Continued Operation was providied by Georgia Power Company in the I. E. Bulletin 79-01B Status Update, dated January 3, 1983 and is still applicable.
b