HL-1250, Forwards Post-Refueling Outage Startup Test Rept,Unit 1 Cycle 13, Per Tech Spec 6.9.1.1.Rept Presents Static & Dynamic Functional Core Tests Performed During Startup from Spring 1990 Maint/Refueling Outage

From kanterella
Jump to navigation Jump to search
Forwards Post-Refueling Outage Startup Test Rept,Unit 1 Cycle 13, Per Tech Spec 6.9.1.1.Rept Presents Static & Dynamic Functional Core Tests Performed During Startup from Spring 1990 Maint/Refueling Outage
ML20059C644
Person / Time
Site: Hatch Southern Nuclear icon.png
Issue date: 08/27/1990
From: Hairston W
GEORGIA POWER CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20059C648 List:
References
HL-1250, NUDOCS 9009050235
Download: ML20059C644 (2)


Text

yy < <

.-m e '- - -

h/f- , [o .. Georg.a Power Company.  ;

]

D

t4N ' * ' ' - -

t 333 Piedmont Avenue - ' '

'f

, ' Atlanta. Georp<a 30308 --'

, _ Tschone 474 526 3195 I:- JU C ~ l Ma+ng Aposs .

.~.

G' do inwrness Conter Parkway - A. : 1 h Post Offce Box 1295 " b

~

,l

, - Ermingham. Abbama 35201 - .

! Tetephone 205 608 5581 .i

$hy

  • the soutten elect'c system -

W. G. Hairston, HI

. Senior Vce Presdont '!

- Nuclear Oystions .  ;

F HL-1250 l

  1. ,, _000925_

August 27, 1990 {

i' LU.S.: Nuclear Regulatory Commission ,

. ATTN: . Document Control Deak Washington, D.C. 20555 H -PLANT HATCH - UNIT 1

,, NRC DOCKET 50-321 5 OPERATING LICENSE DPR-57 i PLANT'STARTUP TEST

SUMMARY

REPORT Gentlemen: ,

Per _ 'the ' requirements of Plant Hatch Unit 1 Technical Specification 6.9.1.1, Georgia Power Company (GPC) hereby submits a Plant Startup Test

t iSummary. Report. The report presents the results of the static'and dynamic ,

functional' core tests performed during startup from the Spring 1990 Unit 1 -,

" maintenance / refueling (M/R) outage. The unit .is not o)erating in l

- Cycle 13. . .The report is being subsD.:ed since a-reinnd batc1 of-General t Electric' GE-9 fuel bundles .are inclv.ed in this reload core. . This fuel-  !

bundlet design has'been reviewed and approved by the NRC via NEDE-24011-P, "Generai . Electric Standard Application of Reactor Fuel.'" As expected, the i testing ' identified no unexpected behavior of the reactor core and instrumentation. l Please contact this office if you have questions.

Sincerely, [

-i A.ph h

> W. G. Hairston, III -i r

GKM/eb

Enclosure:

Post Refueling Outage Startup Test Report - Unit 1 Cycle 13 M c: (See next page.)

p,., >

900905023L 90082'7 / '(

PDR ADOCK 05000321 p PDC

~

,+ .

y{T w . ,:-  :

GeolplaPour Ab  !

Ib !l D ~ U.S. Nuclear Regulatory Commission.

l August > 27, 1990 ,

Page :Two I

c: _ Georaia Power comoany Mr. H. C. Nix, General Manager - Nuclear Plant Mr. J.-D. Heidt, Manager Engineering and Licensing - Hatch , 1 GO-NORMS

. U.S. Nuclear Reaulatory Commission. Washindton. 'D.C.' ' -i Mr. L. P. Crocker,-Licensing Project Manager - Hatch U.S.' Nuclear Reaulatory Commission. Reaion II- '

j Mr.-5..D.:Ebneter, Regional Administrator

=i r Senior Resident Inspector - Hatch l

i i

r k

000925