Forwards Reg Guide 1.97 Rept Re Emergency Response Capability/Instrumentation
ML20112G402
Person / Time
Site: Fort Saint Vrain Xcel Energy icon.png
Issue date: 02/28/1985
From: Warembourg D
PUBLIC SERVICE CO. OF COLORADO
To: Johnson E
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
Shared Package
ML20112G407 List:
References
RTR-REGGD-01.097, RTR-REGGD-1.097 GL-82-33, P-85065, TAC-51092, NUDOCS 8504010108
Download: ML20112G402 (1)


Text

-

, , a.4 Public Service Company cf Odlcredo V February 28, 1985 Fort St. Vrain Unit No. 1 P-85065 Regional Administrator _

Region IV mM@MDURN Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 1000 ggg

(

Arlington, Texas 76011 u\_ -

Attention: Mr. Eric H. Johnson DOCKET NO. 50-267

SUBJECT:

Emergency Response Capabilities, Regulatory Guide 1.97

REFERENCES:

(1) Generic Letter 82-33 (G-83009) Dated 12/17/82 (2) PSC Letter P-83147, Lee to Denton, Dated 4/14/83 (3) PSC Letter P-84079, Brey to Collins, Dated 3/09/84

Dear Mr. Johnson:

The purpose of this letter is to provide you with Public Service Company's report regarding Regulatory Guide 1.97 Instrumentation.

If you have any questions, please contact Mr. M. H. Holmes at (303) 571-8409.

Very truly yours,

h. $-

D. W. Warembourg, U Manager, Nuclear Engineering Division DWW/ MEN /ksc attachment o

I

( b Ho e #

R82 *1 &1 !!888867 F PDR gd# og_i d