ML20065S264: Difference between revisions

From kanterella
Jump to navigation Jump to search
(StriderTol Bot insert)
 
(StriderTol Bot change)
 
(One intermediate revision by the same user not shown)
(No difference)

Latest revision as of 04:11, 6 January 2021

Forwards Ltr Requesting Temporary Approval for Use of Betz Products Peco 3,PEC10 & PEC12 for 6-month Period.Chemicals Replacements for Currently Used Peco 4 & Peco 5 & Will Be Used for Corrosion & Deposition Control in CWS
ML20065S264
Person / Time
Site: Limerick  Constellation icon.png
Issue date: 05/11/1994
From: Matty R
PECO ENERGY CO., (FORMERLY PHILADELPHIA ELECTRIC
To: Garg S
PENNSYLVANIA, COMMONWEALTH OF
References
NUDOCS 9405170251
Download: ML20065S264 (17)


Text

. . -. . . . .

L . ,

_s PECO ENERGY "e m --

2301 Market Street Po Box 8699 Phiadelphra. PA 19101 4699 215 841 4000 May 11,1994 Mr. Sohan Garg Bureau cf Water Management Department of Environmental Resources Suite 6010, Lee Park 555 North Lane Conshohocken, PA 19428

Dear Mr. Garg:

Subject:

Limerick Generating Station NPDES Pennit No. PA0051926 As per our recent meeting at Limerick Generating Station, enclosed is a letter requesting a temporary approval for the use of Betz products PECo 3, PEC10 and PECl2. The chemicals are replacements for the currently used PECo 4 and PECo 5 and will be used for corrosion and deposition control in the cooling water system. As.

was discussed at our meeting, the current fonnulations have performed well, however,

. the active components are not combined to provide Dexibility in optimizing chemical l usage. By using the same active components in a three product program, we can j improve performance of the program, reduce costs, and reduce environmental discharges.

We are requesting that the approval be for a 6-month period. During this time, a competitive bid process for a replacement program will be completed. At that time, we will petition the Department for a permanent amendment to the permit.

Enclosed is additional infonnation concerning usage rates, Material Safety Data ,

Sheets, and Aquatic Toxicity Data. Since this program will result in significant benefits to both station operations and the environment, your immediate attention to this matter would be appreciated.

A copy'of this letter (including any attachments or enclosures) is being sent to the U.S. Nuclear Regulatory Commission (USNRC) in accordance with the Limerick Generating Station, Units 1 and 2, Environmental Protection Plan, Section 3.2, which stipulates that USNRC shall receive a copy of any proposed changes to the NPDES permit at the same time that the permitting agency is notified.

940517o251 DR 940511 p ADOCK 05000352 0' PDR

If you have any questions or require additional information, please contact me at (215) 841-5177.

Sincerely, hMW .

Robert M. Matty, Jr.

Engineer Environmental Affairs f

i l

i Attachment ec: U.S. Nuclear Regulatory Commission, Document Control Desk (Docket Nos. 50-352 and 50-353 & License Nos. NPF-39 and NPF-85)

T. T. Martin, Administrator, USNRC, Region 1 N. S. Perry, USNRC Senior Resident Inspector, LGS

L1MER1Cx GENERATING STATION PLANT DIVISION Chemistry Section April 14, 1994 FROM: R. W. Boyce TO: G. M. Morley SUELTECT: LGS NPDES PERMIT PA0051926 REVISION -

Currently, both LGS cooling towers are treated with two +

blended products, PECo4 and PECo5, for the control of cooling water system corrosion and deposition. While these products have .

performed well, it has become apparent that the active components are not combined to provide the most flexibility in optimizing -

chemical usage. As a result, at times the products must be either

overfed or underfed, in an attempt to satisfy both treatment needs and discharge limitations.

While this situation has inherent plant corrosion and fouling concerns, it also does not provide the fullest capability to optimize chemical usage. After extensive evaluations with our water treatment vendor, we have concluded that the same active ,

components could be added via a three product program. The flexibility of this three product program will enable us to better tailor our addition to daily conditions, thus improving '

performance, reducing our costs, and reducing environmental discharges. Since both the reissuance of our new NPDES permit and the rebidding of our cooling water treatment contract will not be completed for a number of months, we wish to implement this change as an interim measure, so that these benefits can be realized.

The three new products would be BETZ PECo 3, PEC10, and PEC12.

A discussion on each follows, and a summary of the requested limits is attached. These limits were derived from the equivalent active ingredients in our currently approved discharges. Thus this request does not involve additional levels of chemical discharges.  ;

1) PECo3--This product is a copper corrosion inhibitor, and is 50% sodium tolyltriazole (TTA). PECoS is 5% TTA.

Since there is no environmentally ~ approved test method for TTA, we request a gallon per day usage limit on PECo3. In the event that discharge limits are imposed, we request that they be one ' tenth of the current PECo5 limits, with the understanding that an unapproved method will be used.

2) PEC10--This product is a blend of orthophosphate and zinc, and is specifically for carbon steel corrosion control.

Currently, PECo4 contains the zinc, and PECoS~ the orthophosphate. The current configuration often prevents chemical treatment reductions due to the potential impact on J

l

1 l

, i l

  • l the levels of the other active components. For example, cooler weather, and/or increases in naturally occurring river phosphate levels, requires less corrosion inhibitor. We currently cannot respond to these situations, due to the need to maintain the fouling control agents at an acceptable level. <

Our requested PEC10 limits are based on the equivalent $

orthophosphate levels in our current PECoS usages and  !

discharges. We intend to monitor zine levels as the means of determining PEC10 concentration. Please note, however, that the limits correspond to a monthly average zinc concentration ,

that is within the 0.7 ppm limit proposed in our pending NPDES '

permit revision. ,

3) PEC12--This product contains the organic polymer, HPS-1, i currently added through PECo4, and a scale inhibitor, HEDP, '

currently added via PEco5, at 5% strength. Since HPS-1 is essentially non-toxic, the PECl2 toxicity is due to HEDP. Our requested limits were based on the equivalent amount of HEDP  ;

that is currently added via PECo5. Since both of these j analytical methods are not highly accurate, we would prefer a  !

usage rate only. However, in the event that discharge limits  !

are imposed, the limits requested are based on equivalent' '

amounts of HEDP in'our current products.

In summary, these changes represent a_ less adverse environmental impact, imp::oved quality, and improved cost performance. Furthermore, this plan was discussed on 3/31/94 with  :

Sohan Garg, of the PADER, ar.d Bob Matty, from your staff, during a meeting to review the forthcoming permit reissuance. Schan was very receptive to the merits of this change, and indicated that -

approval could be granted relatively quickly, especially on a trial basis. Therefore, we request approval for a 6 month trial. It is our intention to have completed the competitive bidding process within that time period, and to have requested permanent approval for this program or a similar program provided by another vendor. <

A favorable response to this request is desired by 5/13/94.

Attached is the necessary product information, and our BETZ representative, Steve Jordan, is available to resolve any questions the PADER may have, as has been done in the past. If there are any questions, please contact Steve Dietch at extension'2711.

, f- .

h- Robert W. Boyce Plant Manager cc: J. L. Kantner I K. S. Kemper l C. G. Diehl I i

- 1 , , ,

S S U U O l O l EM / EM /

l ,

NU g NU g /

AM g A m AM m A m TI / TI NX NX /

AA N 6 6 N 8

. AA 9

_ TM 9 TM . 0 S 4 S .

N 4 7 N

I I Y Y L c L I n I A i l l l Z / A D g D /

g /

g E l m E m A m _

G / G /

A g 7 7 N 4 R m . A 9 9 R .

M E E .

2 V 0 2 2 V 4 A A 1 A

R M

_ G A E E O G R G A A R R G R -

E l E l 1 l P V / O V / / /

A g g g g A m A m R m m Y / Y T L N 8 P L 8 7 2 H 9 H 9 . .

N T 1 T . 8 8 e N N 1 2 E O W O M M +

R E R N U

T T C I I MM d d MM UI p p UI d d d ML ML p p p I g g g g g I

XE 0 0 XE .

AG 0 0 AG 0 7 1 MA 4 4 MA 4 7 7 S S 1 5 U U

) *

) s 1 ) o s -

- h) ))

. S o Pc 1P m

) P h) ) n D cH n

PP) A Oi SE DA T Z PH i% OET T  % H w

4 z5 S HT 3 05% 2  % ,

o . o% o% 1 5 1%5 C%3 C0%% C0 C2 . C1 . -

E51 E155 E5 E27 E23 P(( P((( P( P(( P((

4

_ . . __ . ___ - . ___ ._ . - ._ __ m . _ . _ . . .

BETZ LABORATORIES,INC.

4636 SOMERTON ROAD, TREVOSE, PA. 19053 l BETZ MATERIAL SAFETY DATA SHEET EMERGENCY TELEPHONE (HEALTH / ACCIDENT) 800-877-1940 )

(PAGE 1 OF 3)' t PRODUCT : POWERLINE PEC03 EFFECTIVE.DATE:04-02-93 PRINTED: 04-02-93 REVISIONS TO SECTIONS: ; EDIT: PROD. APP.

PRODUCT APPLICATION: WATER-BASED CORROSION INHIBITOR.


SECTION 1-----------HAZARDOUS INGREDIENTS---------------------------

INFORMATION ON PHYSICAL HAZARDS, HEALTH HAZARDS, PEL'S AND TLV'S FOR SPECIFIC PRODUCT INGREDIENTS AS REQUIRED BY THE OSHA HAZARD COMMUNICATIONS STANDARD'IS LISTED. REFER TO SECTION 4 (PAGE 2) FOR OUR ASSESSMENT OF THE POTENTIAL ACUTE AND CHRONIC HAZARDS OF THIS FORMULATION.

BENZOTRIAZOLE, METHYL, SODIUM SALT ***CAS# 64665-57-2; CORROSIVE TO EYES AND SKIN; TOXIC (ORAL INGESTION); PEL:NOT DETERMINED;TLV:NOT-DETERMINED I

r r


SECTION 2- ---------TYPICAL PHYSICAL DATA--------------------------

PH: AS IS (APPROX. ) 13.0 ODOR: MILD +

FL.PT.(DEG.F): ) 200 SETA(CC) SP.CR.(70F): 1.192 VAPOR PRESSURE (mmHG): ND VAPOR DENSITY (AIR =1): ND VISC cps 70F: 78  % SOLUBILITY (WATER): 100.0 EVAP RATE: ( 1.00(ETHER =1) APPEARANCE: AMBER '

PHYSICAL STATE: LIQUID FREEZE POINT (DEG.F): -25.00


SECTION 3- ---------REACTIVITY DATA--------------------------------

STABLE.MAY REACT WITH ACIDS.DO NOT CONTAMINATE. BETZ TANK. CLEAN-OUT CATEGORY 'C' ,

THERMAL DECOMPOSITION (DESTRUCTIVE FIRES) YIELDS ELEMENTAL OXIDES.

i s

-- , , , +,-_ w

4 BETZ MATERIAL SAFETY DATA SHEET (PAGE 2 OF 3)

PRODUCT : POWERLINE PEC03 .


SECTIONJ4---------HEALTH HAZARD EFFECTS--------------------------- t

- ACUTE SKIN EFFECTS PRIMARY ROUTE OF EXPOSURE

-CORROSIVE TO' SKIN

. ACUTE EYE EFFECTS *** '

CORROSIVE TO THE EYES ACUTE RESPIRATORY EFFECTS ***

MISTS / AEROSOLS CAUSE IRRITATION TO UPPER RESPIRATORY TRACT

' CHRONIC EFFECTS OF OVEREXPOSURE ***

PROLONGED OR REPEATED CONTACT MAY CAUSE TISSUE-NECROSIS.

MEDICAL CONDITIONS AGGRAVATED ***

NOT KNOWN SYMPTOMS OF EXPOSURE ***

CAUSES REDNESS OR ITCHING OF SKIN,POSSIBLY LEADING TO BURNS, DEPENDENT'ON LENGTH OF EXPOSURE.

~ PRECAUTIONARY STATEMENT BASED ON TESTING RESULTS MAY BE TOXIC IF ORALLY INGESTED. i


SECTION 5-----------FIRST AID INSTRUCTIONS------- --------------- -----

SKIN CONTACT * *

  • REMOVE CLOTHING. WASH AREA WITH LARGE AMOUNTS OF SOAP SOLUTION OR WATER FOR 15 MIN.IMMEDIATELY CONTACT PHYSICIAN EYE CONTACT *** i IMMEDIATELY FLUSH EYES WITH WATER FOR 15 MINUTES.IMMEDIATELY CONTACT A PHYSICIAN FOR ADDITIONAL TREATMENT INHALATION EXPOSURE ***

REMOVE VICTIM FROM CONTAMINATED AREA. APPLY NECESSARY FIRST AID ,

TREATMENT.IMMEDIATELY CONTACT A PHYSICIAN.  ;

INGESTION ***

DO NOT FEED ANYTHING BY MOUTH TO AN UNCONSCIOUS OR CONVULSIVE VICTIM DO NOT-INDUCE VOMITING.IMMEDIATELY CONTACT PHYSICIAN. DILUTE CONTENTS OF STOMACH USING 3-4 GLASSES MILK OR WATER


SECTION 6-----------SPILL, DISPOSAL AND FIRE INSTRUCTIONS------- ---

SPILL INSTRUCTIONS ***

VENTILATE, AREA,USE SPECIFIED PROTECTIVE EQUIPMENT.CONTAIN AND ABSORB ON ABSORBENT MATERIAL. PLACE IN WASTE DISPOSAL CONTAINER.THE WASTE CHARACTERISTICS OF THE ABSORBED MATERIAL,OR ANY CONTAMINATED SOIL SHOULD BE DETERMINED IN ACCORDANCE WITH RCRA REGULATIONS.

FLUSH AREA WITH WATER. WET AREA MAY BE SLIPPERY. SPREAD SAND / GRIT. 3 DISPOSAL INSTRUCTIONS ****

WATER CONTAMINATED WITH THIS PRODUCT MAY BE SENT TO A SANITARY SEWER TREATMENT FACILITY,IN ACCORDANCE WITH ANY LOCAL AGREEMENT,A PERMITTED WASTE TREATMENT FACILITY OR DISCHARGED UNDER A NPDES PERMIT PRODUCT (AS IS) -

INCINERATE OR BURY IN APPROVED LANDFILL FIRE EXTINGUISHING INSTRUCTIONS ***

FIREFIGHTERS SHOULD WEAR POSITIVE PRESSURE SELF-CONTAINED BREATHING APPARATUS (FULL FACE-PIECE TYPE). PROPER FIRE EXTINGUISHING MEDIA:

DRY CHEMICAL, CARBON DIOXIDE, FOAM OR WATER

.- - - . - . _~ .. _~ . ,

t BETZ MATERIAL SAFETY DATA SHEET (PAGE 3 OF 3)

. PRODUCT : POWERLINE'PEC03 .


SECTION 7-----------SPECIAL PROTECTIVE EQUIPMENT-------------

USE PROTECTIVE EQUIPMENT IN ACCORDANCE WITH 29CFR SECTION 1910.132-134.USE RESPIRATORS WITHIN USE LIMITATIONS OR ELSE USE SUPPLIED AIR RESPIRATORS. '

VENTILATION PROTECTION ***

ADEQUATE VENTILATION ,

RECOMMENDED RESPIRATORY PROTECTION *** i IF VENTILATION IS INADEQUATE OR SIGNIFICANT PRODUCT EXPOSURE IS LIKELY, USE A RESPIRATOR WITH. DUST / MIST FILTERS.

' RECOMMENDED SKIN PROTECTION ***

GAUNTLET-7YPE RUBBER GLOVES, CHEMICAL RESISTANT APRON

-WASH OFF AFTER EACH USE REPLACE AS NECESSARY. ,

RECOMMENDED EYE PROTECTION ***

SPLASH PROOF CHEMICAL GOGGLES. FACE SHIELD


SECTION 8-----------STORAGE AND HANDLING PRECAUTIONS----------------- -,

~ STORAGE INSTRUCTIONS ***

KEEP CONTAINERS CLOSED WHEN NOT IN USE.

STORE IN COOL VENTILATED LOCATION. STORE AWAY FROM OXIDIZERS HANDLING INSTRUCTIONS ***  ;

ALKALINE. CORROSIVE (SKIN / EYES).DO NOT MIX WITH ACIDIC MATERIAL.

THIS MSDS WAS WRITTEN TO COMPLY WITH THE OSHA HAZARD COMMUNICATION STANDARD .;

APPENDIX: REGULATORY INFORMATION -

THE CONTENT OF THIS APPENDIX REPRESENTS INFORMATION KNOWN TO BETZ ON THE EFFECTIVE DATE OF THIS MSDS. THIS INFORMATION IS BELIEVED TO BE ACCURATE. ,

ANY CHANGES IN REGULATIONS WILL RESULT IN UPDATED VERSIONS OF THIS DOCUMENT.

...TSCA: ALL COMPONENTS OF THIS PRODUCT ARE LISTED IN THE TSCA INVENTORY ';

... REPORTABLE QUANTITY (RQ) FOR UNDILUTED PRODUCT:

NOT APPLICABLE

... RCRA: IF THIS PRODUCT IS DISCARDED AS A WASTE,THE RCRA HAZARDOUS WASTE IDENTIFICATION NUMBER IS:D002= CORROSIVE (SKIN,PE) .

... DOT HAZARD /UN#/ER GUIDE # IS : CORROSIVE TO SKIN /UN1760/#60

. . . CALIFORNIA SAFE DRINKING WATER ACT- (PROPOSITION 65) MATERIALS:NONE

. .. SARA SECTION 302 CHEMICALS:NONE-

. .. SARA SECTION 313 CHEMICALS:NONE

.. SARA SECTION 312 HAZARD CLASS:IMMEDIATE(ACUTE); DELAYED (CHRONIC)

. .. MICHIGAN CRITICAL MATERIALS: NONE

~ NFPA/HMIS : HEALTH - 3; FIRE '- 1; REACTIVITY - 0; SPECIAL - CORR; PE - D i

\

I 1

I l

T BETZ LABORATORIES.INC.

4636 SOMERTON ROAD, TREVOSE. PA. 19053 BETZ MATERIAL SAFETY DATA SHEET EMERGENCY TELEPHONE (HEALTH / ACCIDENT) 800-877-1940 (PAGE 1 OF 3)

. PRODUCT : POWERLINE PEC10 EFFECTIVE DATE:12-AUG-92 DATE PRINTED: 12-AUG-92 PRODUCT APPLICATION : FUEL TREATMENT


SECTION 1-----------HAZARDOUS INGREDIENTS---------------------------

t' INFORMATION ON PHYSICAL HAZARDS, HEALTH HAZARDS. PEL'S AND TLV'S FOR SPECIFIC PRODUCT INGREDIENTS AS REQUIRED BY THE OSHA HAZARD COMMUNICATIONS STANDARD IS LISTED. REFER TO SECTION 4 (PAGE 2) FOR OUR ASSESSMENT OF THE POTENTIAL ACUTE AND CHRONIC HAZARDS OF THIS FORMULATION.

PHOSPHORIC ACID ***CAS# 7664-38-2; CORROSIVE; PEL:1MG/M3iTLV:1MG/M3:

ZINC SULFATE ***CAS# 7733-02-0; SEVERE IRRITANT: POTENTIAL REPRODUCTIVE TOXIN;PEL:NONE;TLV:NONE; i


SECTION 2-----------TYPICAL PHYSICAL DATA--------------------------

PH: AS IS(APPROX.) 1.4 ODOR: NONE FL.PT.(DEG.F);> 200 SETA(CC) SP.GR.(70F): 1.398 VAPOR PRESSURE (mmHG): 18.0 VAPOR DENSITY (AIR =1) : < 1.00 VISC cps 70F: 15  % SOLUBILITY (WATER) : 100.0 EVAP RATE: < 1.00(ETHER =1) APPEARANCE: COLORLESS PHYSICAL STATE: LIQUID FREEZE POINT (DEG.F) : -13.00


SECTION 3-----------REACTIVITY DATA--------------------- ----------

STABLE. BETZ TANK CLEAN-OUT CATEGORY 'B'

' THERMAL DECOMPOSTION (DESTRUCTIVE FIRES) YIELDS ELEMENTAL. OXIDES.

I i

I i

. -. - -. . . - - . , .~ .

. } ,

  • a BETZ MATERIAL SAFETY DATA SHEET (PAGE 2 OF 3)

LPRODUCT-: POWERLINE PEC10-


SECTION~4---------HEALTH HAZARD EFFECTS-------------- ------------

ACUTE SKIN EFFECTS *** PRIMARY ROUTE OF EXPOSURE MAY'CAUSE MODERATE IRRITATION TO THE SKIN ACUTE EYE EFFECTS ***  !

SEVERE IRRITANT TO THE EYES, POSSIBLY CORROSIVE

' ACUTE RESPIRATORY EFFECTS ***

MISTS / AEROSOLS,CAUSE IRRITATION TO UPPER RESPIRATORY TRACT

~

CHRONIC EFFECTS OF OVEREXPOSURE *** j PRODUCT OR PRODUCT COMPONENT MAY CAUSE REPRODUCTIVE TOXICITY AT MATERNAL TOXIC LEVELS (BASED ON ANIMAL TESTING).

MEDICAL CONDITIONS AGGRAVATED *** l NOT KNOWN SYMPTOMS OF EXPOSURE ***

MAY CAUSE REDNESS OR ITCHING OF SKIN.


SECTION 5-----------FIRST AID INSTRUCTIONS- --------------------------- '

SKIN CONTACT *** l REMOVE CONTAMINATED CLOTHING. WASH EXPOSED AREA WITH A LARGE QUANTITY OF SOAP SOLUTION OR WATER FOR 15 MINUTES EYE CONTACT ***

  • IMMEDIATELY FLUSH EYES WITH WATER FOR 15 MINUTES.IMMEDIATELY CONTACT A PHYSICIAN FOR ADDITIONAL TREATMENT ,

INHALATION. EXPOSURE ***

REMOVE VICTIM FROM CONTAMINATED AREA TO FRESH AIR. APPLY APPROPRIATE FIRST AID TREATMENT AS NECESSARY  ;

' INGESTION ***

DO NOT FEED ANYTHING BY MOUTH TO AN UNCONSCIOUS OR CONVULSIVE VICTIM DO NOT INDUCE VOMITING.IMMEDIATELY CONTACT PHYSICIAN. DILUTE CONTENTS OF i STOMACH USING 3-4 GLASSES MILK OR WATER i


SECTION 6-----------SPILL, DISPOSAL AND FIRE INSTRUCTIONS----------- .

SPILL INSTRUCTIONS *** .

]

VENTILATE, AREA,USE SPECIFIED PROTECTIVE EQUIPMENT.CONTAIN AND ABSORB ON ABSORBENT MATERIAL. PLACE IN WASTE DISPOSAL CONTAINER.THE WASTE  !

CHARACTERISTICS OF THE ABSORBED MATERIAL,OR ANY CONTAMINATED SOIL  !

SHOULD BE DETERMINED IN ACCORDANCE WITH RCRA REGULATIONS.

FLUSH AREA WITH WATER. WET AREA MAY BE SLIPPERY. SPREAD SAND / GRIT.

DISPOSAL INSTRUCTIONS ****

WATER CONTAMINATED WITH THIS PRODUCT MAY BE SENT TO A SANITARY SEWER TREATMENT FACILITY,IN ACCORDANCE WITH ANY LOCAL AGREEMENT,A PERMITTED WASTE TREATMENT FACILITY OR DISCHARGED UNDER A NPDES PERMIT PRODUCT (AS IS)-

INCINERATE OR BURY IN APPROVED LANDFILL FIRE EXTINGUISHING INSTRUCTIONS ***

FIREFIGHTERS SHOULD WEAR POSITIVE PRESSURE SELF-CONTAINED BREATHING APPARATUS (FULL PACE-PIECE ' TYPE) . PROPER FIRE EXTINGUISHING MEDIA: j DRY CHEMICAL, CARBON DIOXIDE, FOAM OR WATER '

4 a

4

- . - ~ - . . . - . - . . _. .

BETZ MATERIAL SAFETY DATA: SHEET (PAGE 3 OF 3)

PRODUCT : 'POWERLINE PEC10 --


SECTION 7-----------SPECIAL PROTECTIVE EQUIPMENT-----------

1910.132-134.USE USE PROTECTIVE EQUIPMENT-IN ACCORDANCE WITH 29CFR SECTION RESPIRATORS WITHIN USE LIMITATIONS'OR ELSE USE SUPPLIED AIR RESPIRATORS.

VENTILATION PROTECTION ***

ADEQUATE-VENTILATION TO MAINTAIN AIR CONTAMINANTS BELOW EXPOSURE LIMITS RECOMMENDED RESPIRATORY PROTECTION ***

IF-VENTILATION IS INADEQUATE OR SIGNIFICANT PRODUCT EXPOSURE IS LIKELY, .

USE HIGH EFFICIENCY PARTICULATE CARTRIDGES RECOMMENDED SKIN PROTECTION *** '

' RUBBER GLOVES 4 WASH OFF AFTER EACH USE REPLACE AS NECESSARY.

RECOMMENDED EYE PROTECTION *** J

-SPLASH PROOF CHEMICAL GOGGLES t


SECTION 8----- -----STORAGE AND HANDLING PRECAUTIONS--------- -------

STORAGE INSTRUCTIONS ***

KEEP CONTAINERS CLOSED WHEN NOT IN USE.

PROTECT FROM FREEZING HANDLING INSTRUCTIONS *** -

ACIDIC. CORROSIVE (METAL).DO NOT MIX WITH ALKALINE MATERIAL. ,

THIS MSDS WAS WRITTEN TO COMPLY WITH THE OSHA HAZARD COMMUNICATION STANDARD APPENDIX: REGULATORY INFORMATION ,

LTHE CONTENT OF THIS APPENDIX REPRESENTS INFORMATION KNOWN TO'BETZ ON.THE '

EFFECTIVE DATE OF THIS MSDS. THIS INFORMATION IS BELIEVED TO BE ACCURATE.

100( CHANGES IN REGULATIONS WILL RESULT IN UPDATED VERSIONS OP THIS DOCUMENT.

...TSCA: ALL COMPONENTS OF THIS PRODUCT ARE LISTED IN THE TSCA' INVENTORY 9

. . . REPORTABLE QUANTITY (RQ) FOR UNDILUTED PRODUCT:

1,852 GALLONS DUE TO PHOSPHORIC ACID;417' GALLONS DUE TO ZINC' SULFATE;

... RCRA: IF THIS PRODUCT IS DISCARDED AS A WASTE,THE RCRA HAZARDOUS WASTE-- >

IDENTIFICATION NUMBER IS : D0 0 2= CORROSIVE (PH , STEEL) .

... DOT HAZARD /UN#/ER GUIDE # IS : CORROSIVE TO STEEL /UN1805/#60

... CALIFORNIA SAFE DRINKING WATER ACT (PROPOSITION 65) MATERIALS:NONE

... SARA SECTION 302 CHEMICALS:NONE

... SARA SECTION 313 CHEMICALS: PHOSPHORIC ACID (CAS#~ 7664-38-2), 21.0-30.0%

ZINC SULFATE (CAS# 7733-02-0), 21.0-30.0% '

... SARA SECTION 312 HAZARD CLASS:IMMEDIATE(ACUTE); DELAYED (CHRONIC)

,.. MICHIGAN CRITICAL MATERIALS: ZINC SULFATE (CAS# 7733-02-0)

NFPA/HMIS : HEALTH - 2; FIRE - 0; REACTIVITY - 0; SPECIAL - CORR; PE - B a + ,

'?

, _ _ - - - m., . .. ~. . , _ - - _ - - - _ .

,- - . .- . _. - . - . - . - . - . . . ~ . . _ . . .-

BETZ LABORATORIES,INC.

4636.SOMERTON-ROAD, TREVOSE, PA. 19053 BETZ MATERIAL SAFETY DATA SHEET EMERGENCY TELEPHONE (HEALTH / ACCIDENT) 800-877-1940

~(PAGE 1 OF 3)

PRODUCT : POWERLINE PEC12 EFFECTIVE DATE 04-03-92 PRINTED: 6-Apr-1992 PRODUCT APPLICATION : WATER-BASED CORROSION INHIBITOR.


SECTION 1-----------HAZARDOUS INGREDIENTS---------------

INFORMATION ON PHYSICAL HAZARDS, HEALTH HAZARDS, PEL'S AND TLV'S FOR SPECIFIC PRODUCT INGREDIENTS AS REQUIRED BY THE OSHA HAZARD COMMUNICATIONS STANDARD IS LISTED. REFER TO SECTION 4 (PAGE 2) FOR OUR ASSESSMENT:OF THE POTENTIAL ACUTE

.AND CHRONIC HAZARDS OF THIS FORMULATION.

PHOSPHONIC ACID, (1-HYDROXYETHYLIDINE) BIS- (HEDP) * *

  • CAS# 280 9- 21-4 ; EYE IRRITANT:PEL:NONE;TLV:NONE.

SECTION 2-----------TYPICAL PHYSICAL DATA------------------------- ^-

PH: AS IS (APPROX.) 5.4 ODOR: MILD FL.PT.(DEG.F): >200 P-M(CC) SP.GR. (7 0F) OR DENSITY: 1.122 VAPOR PRESSURE (mmHG): 18 VAPOR DENSITY (AIR =1): <1 VISC cps 70F: 22  % SOLUBILITY (WATER) : 100 EVAP. RATE: ND WATER =1 APPEARANCE: YELLOW PHYSICAL STATE: LIQUID FREEZE POINT (DEG.F): 28


SECTION.3-----------REACTIVITY DATA------------------- ----------

STABLE.MAY REACT WITH STRONG OXIDIZERS.DO NOT CONTAMINATE.BETZ-TANK CLEAN-OUT CATEGORY 'B' THERMAL DECOMPOSITION (DESTRUCTIVE FIRES) YIELDS ELEMENTAL OXIDES.

9 BETZ MATERIAL SAFETY DATA SHEET (PAGE 2 OF 3)

' PRODUCT: POWERLINE PEC12


SECTION 4----------~ HEALTH HAZARD EFFECTS------------------------

! ACUTE SKIN-EFFECTS *** PRIMARY ROUTE OF EXPOSURE SLIGHTLY IRRITATING ***

TO THE SKIN ACUTE EYE' EFFECTS MODERATELY IRRITATING TO THE EYES

! ACUTE RESPIRATORY EFFECTS MISTS / AEROSOLS MAY CAUSE IRRITATION TC UPPER RESPIRATORY TRACT CHRONIC EFFECTS OF OVEREXPOSURE ***

NO EVIDENCE OF POTENTIAL CHRONIC EFFECTS.

MEDICAL CONDITIONS AGGRAVATED ***

NOT KNOWN SYMPTOMS OF EXPOSURE *** '

MAY CAUSE REDNESS OR ITCHING OF SKIN.

. -----SECTION 5- ----------FIRST AID INSTRUCTIONS--------- ------- ----

SKIN CONTACT ***

REMOVE CONTAMINATED CLOTHING. WASH EXPOSED AREA WITH A LARGE QUANTITY OF SOAP SOLUTION OR WATER FOR 15 MINUTES I EYE CONTACT ***

IMMEDIATELY FLUSH EYES WITH WATER FOR 15 MINUTES.IMMEDIATELY CONTACT A PHYSICIAN FOR ADDITIONAL TREATMENT INHALATION EXPOSURE ***

REMOVE VICTIM FROM CONTAMINATED AREA TO FRESH AIR. APPLY APPROPRIATE

-FIRST AID TREATMENT AS NECESSARY

. INGESTION *** .

DO NOT FEED ANYTHING BY MOUTH TO AN UNCONSCIOUS OR CONVULSIVE VICTIM DILUTE CONTENTS OF STOMACH. INDUCE VOMITING BY ONE OF THE STANDARD METHODS.IMMEDIATELY CONTACT A PHYSICIAN


SECTION 6--- -------SFILL, DISPOSAL AND FIRE INSTRUCTIONS---------

SPILL INSTRUCTIONS ***

VENTILATE AREA,USE SPECIFIED PROTECTIVE EQUIPMENT.CONTAIN AND ABSORB ON ABSORBENT MATERIAL. PLACE IN WASTE DISPOSAL CONTAINER. THE WASTE CHARACTERISTICS OF THE ABSORBED MATERIAL,OR ANY CONTAMINATED SOIL, SHOULD BE DETERMINED IN ACCORDANCE WITH RCRA REGULATIONS.

FLUSH AREA WITH WATER. WET AREA MAY BE SLIPPERY. SPREAD SAND / GRIT.

DISPOSAL INSTRUCTIONS ***

WATER CONTAMINATED WITH THIS PRODUCT MAY BE SENT TO A SANITARY SEWER TREATMENT FACILITY,IN ACCORDANCE WITH ANY LOCAL AGREEMENT,A PERMITTED WASTE TREATMENT FACILITY OR DISCHARGED UNDER A NPDES PERMIT PRODUCT (AS IS)-

INCINERATE OR BURY IN APPROVED LANDFILL FIRE EXTINGUISHING INSTRUCTIONS ***

FIREFIGHTERS SHOULD WEAR POSITIVE PRESSURE SELF-CONTAINED BREATHING

~

- APPARATUS (FULL FACE-PIECE ' TYPE) . PROPER FIRE EXTINGUISHING MEDIA:

DRY CHEMICAL, CARBON DIOXIDE, FOAM OR WATER

. BETZ MATERIAL-SAFETY DATA SHEET (PAGE 3 OF 3)

PRODUCT: POWERLINE PEC12

~


SECTION 7-----------SPECIAL PROTECTIVE EQUIPMENT----------------- -

USEt PROTECTIVE EQUIPMENT IN ACCORDANCE WITH 29CFR SECTION 1910.132-134. USE

- RESPIRATORS WITHIN-USE LIMITATIONS OR ELSE USE SUPPLIED AIR RESPIRATORS.

VENTILATION PROTECTION ***

ADEQUATE VENTILATION RECOMMENDED RESPIRATORY PROTECTION ***

IF VENTILATION IS INADEQUATE OR SIGNIFICANT PRODUCT EXPOSURE IS LIKELY, USE A RESPIRATOR WITH DUST / MIST FILTERS.

RECOMMENDED SKIN PROTECTION ***

RUBBER GLOVES WASH OFF AFTER EACH USE. REPLACE AS NECESSARY

' RECOMMENDED EYE PROTECTION"**

SPLASH PROOF CHEMICAL GOGGLES


SECTION 8--- -------STORAGE AND HANDLING PRECAUTIONS-------------

STORAGE INSTRUCTIONS ***

KEEP DRUMS & PAILS CLOSED WHEN NOT IN USE. '

IX) NOT FREEZE.IF FROZEN, THAW AND MIX COMPLETELY PRIOR TO USE HANDLING INSTRUCTIONS ***

NORMAL CHEMICAL HANDLING ~

THIS MSDS WAS WRITTEN TO COMPLY WITH THE OSHA HAZARD COMMUNICATION STANDARD APPENDIX: REGULATORY INFORMATION THE CONTENT OF THIS APPENDIX REPRESENTS INFORMATION KNOWN TO BETZ ON THE r EFFECTIVE DATE OF TH:S ME7S. THIS INFORMATION IS BELIEVED TO BE ACCURATE.

ANY CHANGES IN REGULATIONS WILL RESULT IN UPDATED VERSIONS OF THIS DOCUMENT.

...TSCA: ALL COMPONENTS OF THIS PRODUCT ARE LISTED ON THE TSCA INVENTORY

... REPORTABLE QUANTITY (RQ).FOR UNDILUTED PRODUCT:

.NOT APPLICABLE

... RCRA: IF THIS PRODUCT IS DISCARDED AS A WASTE,THE RCRA HAZARDOUS WASTE IDENTIFICATION NUMBER IS: NOT APPLICABLE i

... DOT HAZARD /UN#/ER GUIDE # IS: NOT APPLICABLE

... CALIFORNIA SAFE DRINKING WATER ACT (PROPOSITION 65) MATERIALS: NONE I

.... SARA SECTION 302 CHEMICALS: NONE .

... SARA SECTION 313 CHEMICALS: NONE l

... SARA SECTION 312 HAZARD CLASS: IMMEDIATE(ACUTE) l

... MICHIGAN CRITICAL MATERIALS: NONE 1 NFPA/HMIS : HEALTH - 1 ; FIRE - 1 ; REACTIVITY - 0 : SPECIAL - NONE ; PE - B j i

4

-- , w _ _ _ _ , _ _, ,

l BETZ LABORATORIES 4636 SOMERTON ROAD , TREVOSE, PA 19053 PRODUCT: POWERLINE PEC03 AQUATIC TOXICOLOGY j Daphnia magna 48 Hour Static Acute Bioassay LC50: 311.2 MG/L No effect level: 210 MG/L Bluegill Sunfish 96 Hour Static Acute Bioassay LC50: 109.3 MG/L No effect level: 42 MG/L ,

MAMMALIAN TOXICOLOGY Oral LD50 RAT: >1,400 MG/KG NOTE: ESTIMATED VALUE Dermal LD50 RABBIT: >4,500 MG/KG NOTE: ESTIMATED VALUE t

_ ____. _______ ___.__ . ___ _j

_ _ _ - ~ . . . _ . _ _ - _ . - - - - -

+ ..

i .

l, i

4 i BETZ LABORATORIES 4636 SOMERTON ROAD , TREVOSE, PA 19053 h PRODUCT: POWERLINE PEC12 l AQUATIC TOXICOLOGY l

Daphnia magna (Data generated on similar product)

NOTE: Due to the acidic nature of the test solutions, pH l' was adjusted to levels commonly encountered in treatment waters j

l 48 Hour Static Acute Bioassay j LC50: 1600 MG/L No effect level: 870 MG/L Rainbow Trout (Data generated on similar product)

NOTE: Due to the acidic nature of the test solutions, pH i

was adjusted to levels commonly encountered in treatment waters 1

l 48 Hour Static Screen i 100% Mortality: 10000 MG/L

! No effect level: 4000 MG/L Fathead Minnow (Data generated on similar product) j N3TE: Due to the acidic nature of the test solutions, pH was adjusted to levels commonly encountered in treatment waters 96 Hour Static Acute Bioassay LCSO: 4950 MG/L l No effect level: 2400 MG/L i

MAMMALIAN TOXICOLOGY Oral LD50 RAT: >2,000 MG/KG NOTE: ESTIMATED VALUE I, Dermal LD50 RABBIT: >2,000 MG/KG NOTE: ESTIMATED VALUE i

i-e 0

,-- .~, .-,.,...... _ .. ..-- .. . - _ ,.., ..-,--. _ ___ __._....__ _ __.-____ _ - -

. _ . . . . _ - . _ . . . . ._ ._ . . _ .. _ _ _ _. ._._..m.

~, ,,

i BETZ LABORATORIES 4636 SOMERTON ROAD , TREVOSE, PA 19053 PRODUCT: POWERLINE PEC10 AQUATIC T0XICOLOGY Rainbow Trcut 96 Hour Static Acute Gioassay LC50: 21.3 MG/L No effect level: 15.5 MG/L Daphnia magna 48 Hour Static Acute Bioassay LC50: 3.8 MG/L No effect level: <3.2 MG/L MAMMALIAN TOXICOLOGY NO DATA AVAILABLE i

i l

1 l

l l

n w -s-m- - .-s , e m + en- , ,- - -

-,,- y