Requests That LGS NPDES Permit PA0051926 Be Amended to Allow Use of Chemical Additive Betz Bio-Trol 88P in Cooling Water Sys at LGS
ML20094D990
Person / Time
Site: Limerick  
Issue date: 10/19/1995
From: Matty R
PECO ENERGY CO., (FORMERLY PHILADELPHIA ELECTRIC
To: Garg S
PENNSYLVANIA, COMMONWEALTH OF
References
NUDOCS 9511060328
Download: ML20094D990 (11)


Text

2 v

PECO ENERGY c

esco e,e'ev o c v 2301 Market Street PO Box 6699 FMacelDNa, PA 19101 8699 215 841 4000 October 19,1995 Mr. Sohan Garg Department of Environmental Protection Bureau of Water Quality Management Lee Park, Suite 6010 555 North Lane Conshohocken, PA 19428

Dear Mr. Garg:

Subject:

Limerick Generating Station NPDES Permit No. PA0051926 Pursuant to Chapter 92.7, " Reporting of New or increased Discharges," we are requesting the subject permit be amended to allow the use of the chemical additive Betz Bio-Trol 88P in the cooling water system at Limerick Generating Station. The additive will be used as an attemative to the chlorine and bromine system currently permitted for control of condenser biofouling. Current permit discharge limits for total residual oxidants (TRO) should be applicable for the Betz product.

Usage rate of Bio-Trol 88P is estimated to be 400 lbs/ day as a maximum. This will result in a maximum residual of 0.2 mg/l or less as TRO at outfall 001. As stated earlier, this is consistent with current permit conditions. The additive has been approved by the Depatiment for use at Cromby, Delaware, Schuylkill and Eddystone Stations. Enclosed are the Material Safety Data Sheet and Aquatic Toxicity Data for the additive.

Based on this information and due to recurring problems with the current chlorine and bromine system, we would appreciate a favorable response by November 2,1995.

A copy of this letter (including any attachments or enclosures) is being sent to the U.S.

Nuclear Regulatory Commission (USNRC) in accordance with the Limerick Generating Station, Units 1 and 2, Environmental Protection Plan, Section 3.2, which stipulates that USNRC shall receive a copy of any proposed changes to the NPDES permit at the same time that the permitting agency is notified.

If you have any questions or require additionalinformation, please contact me at (215) 841-5177.

Sincerely, SW Robert M. Matty, r.

Engineer Environmental Affairs gh 9511060328 951019

} }

PDR ADOCK 0500o352 1

P PDR

Attachment

.cc:

U.S. Nuclear Regulatory Commission, Document Control Desk (Docket Nos. 50-352 and 50-353 & License Nos. NPF-39 and NPF-85)

T. T. Martin, Administrator, USNRC, Region 1 N. S. Perry, USNRC Senior Resident Inspector, LGS i

I i

t l

9 4

e 1

i j

pgsy rga w Uto Us vwww Em wwemmrevt5

--w - --

~

~ ~ ~

we BETZ MATERIAL SAFETY DATA SHEET EFFECTIVE DATE: 08-SEP 1995 PRINTED DATE: 08-SEP-1995

1) CHEMICAL PRODUCT AND COMPANY IDENTIFICATION PRODUCT NAME : BIO-TROL 88P REAGENT CODE #

PRODUCT APPLICATION AREA: SOLID MICROBIAL CONTROL AGENT.

COMPANY ADORESS:

Betz Laboratories, Inc.

4636 Somerton Road, Trewse, Pa.19053 Information phone number: (215) 355 3300 EMERGENCY TELEPHONE (HEALTH / ACCIDENT): (800N77-1940 (USA)

2) COMPOSITION / INFORMATION ON INGREDIENTS Information for specrfic product ingredients as required by the OSHA HAZARD COMMUNICATIONS STANDARD is listed. Refer to additional secnons of this MSDS for our assessment of the potential hazards of this formulation.

t HAZARDOUS INGREDIENTS:

CAS*

CHEMICAL NAME 32718 18-6 1-BROMO-3-CHLORO 5,5-OlMETHYLHYDANTOIN Oxidizer; imtant (eyes and skin)

No component is considered to be a carcinogen by the NationalToxicology Program, the Intemational Agency for Research on Cancer, or the Occuoational Safety and Health Administration at OSHA thresholds for carcinogens.

l

____________.-m_________

OCT 24 '95 10 12 FROM LG5 MADWASTE TO 90148062 ~

-- PRUE.YMJ-C-e...

..o

......,n>.,- ---,_v_..-

9.gymm,m3.,3megyppyg4 gmmm PAGE 1 COtJTINUED e

f

'h e

~ V 2

/

.s 9

i 0

e 1

ggir 80 0 @9 1@ s 88 BC2@R 6@g wMgaesnng- --- --- ---- wer s'~~"""~ ~ ~ ' ' ' "'

=

PRODUCT.NAME : BIO. TROT. 88P REAGENT CODE # :

EFFECTIVE DATE:08 SEP.1995

3) HAZARDS IDENTIFICATION

. ~. -...

EMERGENCY OVERVIEW DANGER Moderately irritating. May be corrosive in contact with moist skin.

Severe irritant to the eyes. Dusts cause initation to the upper respiratory trad.

DOT hazard: Oxjdizer Emergency Response Guide #35 Odor: S5ght; Appearance: White, Granules Fire fighters should wear positive pressure self-contained breathing apparatus (fur face piece type). Proper fire-extinguishing media:

Flood with water. Use of CO2 or foam may not be effedive.

POTENTIAL HEALTH EFFECTS ACUTE SKIN EFFECTS:

Primary route of exposure; Moderately imtating. May be corrosive in contact with moist skin.

ACUTE EYE EFFECTS:

Severe irritant to the eyes.

ACUTE RESPIRATORY EFFECTS.

l Du;is cause initabon to the upper resperatory tract.

INGESTION EFFECTS:

May cause severe irritation or buming of the gastrointestinal tact.

TARGET ORGANS:

No evidence of potential chronic effects.

MEDICAL CONDITIONS AGGRAVATED:

Not known.

I SYMPTOMS OF EXPOSURE:

May cause redness or itching of skin.

PAGE 2 CONTINUED I

ocT 24 *@5 16 1 PJ 0$d@R LWN VW7:MWWas r=_ m-~w wv e w / w - =^~ ~ ' '

PRODUCThAME: BIO TROL 88P REAGEN7 CODE # :

EFFECTIVE DATE: 08 SEP 1995

4) FIRST AfD MEASURES SKIN W T ACT:

R: mow dothing. Wash area with large amounts of soap so!ution or water for 15 min. Immediately contact physician.

EYE CONTACT; immediately fbsh eyes with water for 15 minutes, immediately contact a physician for additional treatment.

INHALATION.

R: mow vicilm from contaminated area. Apply necessary first aid trealment. Immediately contact a physidan.

INGESTION.

Do not feed anything by mouth to an unconscious or convulsive vidim. Do not induce vomiting. Immediately contact phys' clan.

Ditute contents of stomach using 3 4 glasses milk or water.

5) FIRE FIGHTING MEASURES FIRE FIGHTING INSTRUCTIONS:

Fire fighters should wear positive pressure self-contained breathing appartus (full face piece type).

EXTINGUISHING MEDIA:

Flood with water, Use of CO2 or foam may not be effedive.

HAZARDOUS DECOMPOSITION PRODUCTS:

Th:rmal decomposition (destruchve fires) yields elemental oxides.

FLASH POINT:

> 200F P-M(CC)

MISCELLANEOUS:

Oxidizer UN1479; Emergency Response Guide #35

6) ACCIDENTAL RELEASE MEASURES PROTECTON AND SPILL CONTAINMENT; Vantilate area. Use specified protedive equipment. Contain and rosorb on absorbent material Place in waste disposal container.

Produd releases chlorine when wet. Spiti resicue may be neutralized with 3% hydrogen peroxide solution.

DISPOSAL INSTRUCTIONS:

Wt t:r contaminated with this product may be sent to a sanitary sewer treatment fadlity.in accordance with any local agreement,a permitted i

waste treatment facility or discharged under a permit. Produd al b Dispose of in approved pesticide facility or according to lao 11 instructions.

j i

PAGE 3 CONTINUED

OCT 24 oG5 1W 3 BJ t$WUW b@s MQ98%TG3 nen:Mrut*Ts

...~.-.~~ ~ ~- ;, :. u,. _. c.

. u..

... " ' ~.

, }~,

j u

l PRODUCT NAME : BIO TROL 88P l

REAGENT CODE #:

EFFECTIVE DATE: 08-SEP 1995 i

)

7) HANDLING A'NO STORAGE HANDLING Oxidizer. Avoid all contact with reducing agents, oils, greases, crganics and acids.

STORAGE:

Keep containers closed when not in use. Keep dry. Do not store at high temperature or near oxidizables or combustibles.

8) EXPOSURE CONTROLS / PERSONAL PROTECTION EXPOSURE LIMITS CHEMICAL NAME 1-BROMO 3-CHLORO-5.5-DIMETHYLHYDANTOIN PEL (OSHA): NOT DETERMINED TLV (ACGlH): NOT DETERMINED MISC: Note. manufacturer's recommended exposure hmit: 0.2 mg/m3.

ENGINEERING CONTROLS:

AdIquate ventilation to maintain air contaminants be, low exposure limits.

PERSONAL PROTECTIVE EQUIPMENT:

Use protective equipment in accordance with 29CFR 1910 Subpart i RESPIRATORY PROTECTION.

A respiratory protection program that meets OSHA's 29 CFR 1910.134 and ANSI Z88.2 requirements must be followed whenever workplace conditions warrant a respirator's use. Use air-punfying respirators within use limitations associated with the equipment or else use supplied air respirators. If air.

purifying respirator use is appropriate, use respirator with acid gas cartridges & dust / mist prefilters.

SKIN PROTECTION:

Gauntiel. type rubber gloves, chemical resistant apron. Wash j

off after each use. Replace as necessary.

)

EYE PROTECTION:

Antight chemical goggles, i

1 l

i pAGE 4 CONTINUED

@@T M

.g

---wa,.a s",,.%, w. : c

..-e a--

43:

R.'? 'd.BS crw EL ?.t v OCT-P W, m 20 Pace i

PRODUCT NAME : BIO-TROL 88P REAGENT CODE # :

EFFECTIVE DATE: 08 SEP 1995

9) PHYSICAL AND CHEMICAL PROPERTIES Density NO DATA Vapor Pressure (mmHG)

<1.0 Freeze Poid (F)

NA Vapor Deruity (air =1) < 1.00 Vacosity (cps 70F) NA

% Solubility (water) 0.2 Odor Slight Appe:rance White Physical State Granules Rash Point (F)

> 200 P-M(CC) pH 5% Disp. (approx.)

4.7 Evaporation Rate (Ether =1)

<1.00 NA = not applicable ND = not determined

10) STABILITY AND REACTIVITY STABILITY:

Stable HAZARDOUS POLYMERIZATION:

Wi!! not occur.

INCOMPATIBILITIES:

Slowly releases halogen gases when contaminated with moisture. May read with alkalles, acids. organics or reducing agents.

DECOMPOSITION PRODUCTS:

Th2rmal decomposition (destructive fires) yields elemental oxides.

BETZ INTERNAL PUMPOUT/ CLEANOUT CATEGORIES:

"B" l

PAGE 5 CONTINUED

@G;V se "ww 3t4 Bar~'WWTd:n*JsswsY13 w w nr w m vwet-mwwwtna

,.a..'

..s.... >...

PRO 6UCT.NAME : BIO-TROL 88P REAGENT CODE # :

EFFECTIVE DATE: 08-SEP 1995

11) TOXICOLOGICAL INFORMATION OralLD60 RAT:

578 mg'kg NOTE 600 mg/kg per alt. source; dehalogenated byproduct rat oral LD50: >4,000 mg/kg Dermal LD50 RABBIT:

>2,000 mg/kg NOTE - ARemate source concurs inhalation LC50 RAT:

1.88 mg/L/4hr NOTE >3.2 mg/U4hr al 100 ppm (no deaths) per alternate source Skin irritation Score RABBIT:

6.1 NOTE - 6.98 per alternate source; reversible; dehalogenated byproduct score: 0.8 Eye irritation Score RABBIT:

103 NOTE - 14 day-ineversible max.at day 3; dehalogenated byproduct score: 12.8-rewrsible 90 D:y Feed Study RAT:

NO DATA NOTE Dehalogenated byproduct 90-day oral LD50: >2,000 mg/kg/ day Skin Sensitization G. PIG:

POSITNE NOTE - Buehler Test: Dehalogenated byproduct was negative in Bu:hier Test Ames AssayBACTERIA:

NEGATNE NOTE +/- metabotic activation: Dehalogenated byproduct: negative Non-Ames Mutagonicity YEAST:

NEGATNE NOTE - Dehalogenated byproduct negative for. Mouse Lymphoma, SCE, Call Transformation Tcratology RAT:

NO DATA NOTE Dehalogenated byproduct study had terata (secondary) at matimal toxic doses R: productive Toxicity RAT:

4,500 mg/kg/ day NOTE Dehalogenated byproduct study had no adverse reproductive toxicity DAGE 6 CONTINUED

OCT 24 *95'10 13 ~ @0SCM b@G 12MLGi&5Y13 MWWUJbes em

]

~

PROD" CT t.4AME : BIO-TROL 88P U

REAGENT CODE # :

EFFECTIVE DATE: 08-SEP 1995 i

12) ECOLOGICAL INFORMATION AQUATIC TOXICOLOGY Rainbow Trout 96 Hour Static Acute Bioassay LC50. 84 mg/L j

Fcthead Minnow 96 Hour Static Acute Bloassay LC50; 2.19 mg/L Daphnia magna 48 Hour Static Acute Bicassay LC50:.45 mg/L She:pshead Minnow 96 Hour Static Acute Bioassay LCSO: 19.5 mg/L BIODEGRADATION COD (mg/gm):

938 TOC (mg/gm):

255 BOD-5 (mg/gm):

6 BOD-28 (mg/gm):

11

,13) DISPOSAL CONSIDERATIONS If this undiluted product is discarded as a waste, the US RCRA haztrdous waste identification number is -

D001 =lgnitable.

Please be advised: however, that state and local requirements for wasta disposal may be more restrictive or otherwise different from federal regulations. Consuit state and local regulations regarding tha proper disposal of this material

14) TRANSPORT INFORMATION DOT HAZARD Oxidizer UN / NA NUMBER-UN1479 DOT EMERGENCY RESPONSE GUIDE a: 35 PAGE 7 CONTINUED

esY so VJTTN 3 eJ UM9W 1CMF~M@ANGYtB ncnsmu*m

- #-~ * -

__= _

.. _ __ z., m_ = w_

w w c a *=dnesa5+= ~ ~ ~ '

PRODUCT 14AME : BIO. TROL 88P REAGENT CODE # :

EFFECTIVE DATE:08.SEP.1995

15) REGULATORY INFORMATON TSCA:

This is an EPA registered biocide and is exempt from TSCA inventory requirements.

CERCLA AND/OR SARA REPORTABLE QUANTITY (RQ):

No regulated constituent present at OSHA thresholds FIFRA REGISTRATON NUMBER:

3876 150 SARA SECTION 312 HAZARD CLASS:

Immediale(acute), Fire SARA SECTION 302 CHEMICALS:

No regulated constituent present at OSHA thresholds SARA SECTION 313 CHEMICALS:

Na regulated constituent present at OSHA thresholds CALIFORNIA REGU'JTORY INFORMATION CALIFORNIA SAFE DRINKING WATER AND TOXIC.

ENFORCEMENT ACT (PROPOSITION 65) CHEMICALS PRESENT:

No regulated constituent present at OSHA thresholds MICHIGAN REGULATORY INFORMATION No regulated constituent present at OSHA thresholds

16) OTHER INFORMATON NFPA/HMIS CODE TRANSLATON H3:lth 2

Moderate Hazard fee 1

Slight Hazard RiactMty 1

Slight Hazard Special OXY DOT or NFPA Oxicizer (1) Protective Equipment C Goggles, Gloves, Apron (1) refer to section 8 of MSDS for additional protective equipment recommendations.

CHANGE LOG EFFECTIVE DATE REVISIONS TO SECTION:

SUPERCEDES MSDS ctatus: 22-AUG.95 REVISED FORMAT DAGE 8

    • TOTAL PAGE.010 **