Requests That Chemical Additive Betz Deposi-Trol 855D Added to Plant NPDES Permit PA0051926
ML20108B319
Person / Time
Site: Limerick  
Issue date: 04/23/1996
From: Matty R
PECO ENERGY CO., (FORMERLY PHILADELPHIA ELECTRIC
To: Garg S
PENNSYLVANIA, COMMONWEALTH OF
References
NUDOCS 9605030254
Download: ML20108B319 (13)


Text

A YECO ENERGY

gof,;;g;7
  • PO Box 8699 Philadelphia, PA 19101 8699 215 841 4000 April 23,1996 Mr. Sohan Garg Department of Environmental Protection Bureau of Water Management Lee Park, Suite 6010 555 North Lane Conshohocken, PA 19428

Dear Mr. Garg:

Subject:

Limerick Generating Station NPDES Permit No. PA0051926 Chemical Additive Betz Deposi-Trol 855D As per our recent telephone conversations, we are requesting that the chemical additive Betz Deposi-Trol 855D be added to Limerick Generating Station's NPDES Permit. The product was originally approved by the Department in 1992 (see attached approval letter). However, it was not included in the new permit issued January 1.1995. The product was approved as a developmental product, Betz DE-1579. Betz has since renamed the product to Deposi-Trol 855D. There is no change in the chemical properties (see attached Betz letter).

In addition, the original approval contained the condition that during use of the product, outfall 001 shall be sampled for totaliron and dissolved iron. The concentrations of the metals are not to exceed 1.5 mg/l and 0.3 mg/l, respectively. We are requesting that the monitoring condition for total and dissolved iron be moved from outfall 001 to the emergency spray pond discharge. Since the additive will be discharged through the spray pond, monitoring at the pond discharge (prior to mixing with cooling tower blowdown) will provide better data concerning iron levels that result due to use of the product. Also, due to varying levels of iron in the river, the specified limits may be exceeded at outfall 001 with no direct correlation to the use of the additive or plant operations.

Enclosed is a copy of the Material Safety Data Sheets (MSDS) and the Aquatic Toxicity Data for the product. At this time, there is a need to treat an emergency diesel generator cooling system with the chemical additive. Since this product has been previously approved, we would appreciate your immediate attention to this matter.

46856 030041 I

4 9605030254 960423 I

PDR ADOCK 05000352 P

PDR

)

j i

A copy of this letter (including any attachments or enclosures) is being sent to the U.S. Nuclear Regulatory Commission (USNRC) in accordance with the Limerick Generating Station, Units 1 and 2, Environmental Protection Plan, Section 3.2, which stipulates that the USNRC shall receive a copy of any proposed changes to the NPDES permit at the same time that the permitting agency is notified.

If you have any questions or require additional information, please contact me at (215) 841-5177.

l Sincerely, A %.

Robert M. Matty, Jr.

Engineer Environmental Affairs Attachment cc:

U.S. Nuclear Regulatory Commission, Document Control Desk (Docket Nos. 50-352 and 50-353 & License Nos. NPF-39 and NPF-85)

T. T. Martin, Administrator, USNRC, Region 1 N. S. Perry, USNRC Senior Resident inspector, LGS 1

l

9 COMMONWEALTH OF PENNSYLVANIA RE EIVED DEPARTMENT OF ENVIRONMENTAL RESOURCES ggp

d. }392 PE N N SYLVANI A M RLEY 60 e

555 North Lane

[M[

Conshohocken, PA 19428 215 832-6130 l

August 31, 1992 Mr. George M. Morley Director, Environmental Affairs Philadelphia Electric Company 2301 Market Street P.O. Box 8699 Philadelphia, PA 19101 Re:

IW NPDES Permit No. PA0051926 Limerick Generating Station Limerick Township Montgomery County

Dear Mr. Morley:

7 This is in response to your June 12, 1992 letter requesting an approval to use chemical additive Betz DE-1579 for the cleaning of a heat exchanger tube at the Limerick Generating Station.

We have completed our review and hereby approve your request. The wastewater will continue to discharge on an average rate of 14.27 million gallons per day I

to the Schuylkill River through Outfall 001. The approval is subject to the following conditions:

1.

The approved additive and usage rate are as follows:

Name Usage Rate (gallons / day)

Betz DE-1579 600 2.

Discharges containing chemical additives to control corrosion, sealing, algae, slime, fouling, oxygen, etc., shall be managed by the permittee to ensure that toxic effects in the receiving stream are prevented.

Usage rates shall be limited to the minimum amount necessary to accomplish the intended purposes of chemical addition.

3.

Accurate records of usage (name of additive, quantity added, date added) of the approved chemical additive and blow down discharge volumes must be maintained and kept onsite by the permittee.

4.

Outfall 001 shall be sampled and analyzed daily for total iron and dissolved iron, tM concentrations for these metals shall not exceed 1.5 mg/l and 0.3 mg/l respcr.tively.

Recycled Paper

l.

l V.

l Mr. George M. Morley August 31, 1992 The existing NPDES Permit will be revised to include this approval once our review of the permit renewal application is completed.

If you have any questions, please feel free to contact Sohan Garg of our. Permits Section.

Very truly yours, JOS PH A. FEOLA Regional Water Quality Manager cc: Limerick Generating Station Limerick Township EPA DRBC Permits & Compliance Re 30 (SH)230.8 i

i

I=11:C1fF4 Water Management Group a.

April 22,1996 Mr. Dave Piller PECO Energy Company Limerick Generating Station Evergreen & Sanatoga Roads Sanatoga, PA 19464

\\

\\

Dear Dave,

3 This is'to confirm that Betz DE1579, which was a developmental cleaning product, was renamed to Betz 855D upon upgrade to full " product" status. There is no difTerence what so ever in the chemical properties of these two products.

Sincerely, Steve Jorda Area Manager Delaware Valley District 1

I APR 22 '96 !!843 FROM LGS RADWASTE TO 8014062 PAGE.001/008 5ETN MkTERfA'L SAFETY DATA SHEET EFFECTIVE DATE: 29-AUG-1995 PRINTED DATE: 09-APR-1996 l

1) CHEMICAL PRODUCT AND COMPANY IDENTIFICATION PRODUCT NAME : DEPOSI-TROL 855D PRODUCT APPLICATION AREA: CHEMICAL CLEANING COMPOUND.

COMPANYADDRESS:

Betz Water Managenwat Group, Division Betz Laboratories,inc.

l 200 Witmer Road Horsham, PA 19044 Information phone number (215) 773-6131 EMERGENCY TELEPHONE (HEALTH / ACCIDENT): (800)-877-1MO (USA) l l

2) COMPOSITION / INFORMATION ON INGREDIENTS Information for specific product ingredients as required by the l

OSHA HAZARD COMMUNICATIONS STANDARD is listed. Refer to additional l

sections of this MSDS for our assessment of the potential hazards of this formulation. This product is subject to the Pennsylvania and New Jersey Worker and Community Right to Know Law.

j HAZARDOUS INGREDIENTS:

l CAS#

CHEMICAL NAME TRADE SECRET INGREDIENT (E195) iTSRN 125438 - 511, lP Irritant (eyes)

TRADE SECRET INGREDIENT (122) ;iTSRN 125438 - 521<iP Potential irritant (eyes)

No component is considered to be a carcinogen by the National Toxicology Program, the Intemational Agency for Research on Cancer, or the Occupational Safety and Health Administration at Pennsylvania thresholds for carcinogens.

t

- - - - ~ - - - - - - - - - ~ ~

RPR 22 '96 11843 FROM LGS RADWASTE TO 8014002 PAGE.002/008 PRODUCT NAME : DEPOSI-TROL 865D EFFECTIVE DATE: 29-AUG-1996 NON-HAZARDOUS INGREDIENTS:

N#

CHEMICAL NAME 7732-18-S WATER TRADE SECRET (NK55) TSRN: 125438 - 5628P l

PAGE 2 CONTINUED l

APR 22 '96 11: 43 FROM LG5 RADWA5TE TO B014062 PAGE.003/008 PR,ODUCT NAM,E : DEPOSI-TROL 855D EFFECTIVE DATE: 29-AUG-1996 i

i

3) HAZARDS IDENTIFICATION u..>

EMERGENCY OVERVIEW WARNING May cause slight irritation to the skin. Severe imtant to the eyes. Vapors, gases, mists and/or aerosols cause irritation to the upper respiratory tract.

DOT hazard: Corrosive to steel i

Emergency Response Guide #

Odor: Pungent; Appearance: Colorless To Green,1.iquid Fire fighters should wear positive pressure self-coritained breathing apparatus (full face-piece type). Proper fire-extingui shing media:

Dry chemical, carbon dioxide, foam or water.

x.e-POTENTIAL HEALTH EFFECTS ACUTE SKIN EFFECTS:

Primary route of exposure; May cause slight irntation to the skin.

ACUTE EYE EFFECTS:

Severe irritant to the eyes, r

ACUTE RESPIRATORY EFFECTS:

Primary route of exposure; Vapors, gases, mists and/or aerosols caum kritation to the upper respiratory tract.

I INGESTION EFFL. TS:

May cause slight gastrointestirul irritation with possible nausea, vomiting, diarrhea, incoordination, mental confusion, dizziness and lethargy.

TARGET ORGANS:

Prolonged or repeated exposures may cause primary imtant derma' itis and/or toxicity to the lung.

i MEDICAL CONDITIONS AGGRAVATED:

Not known.

SYMPTOMS OF EXPOSURE: I i

inhalation may cause irritation Af the respiratory tract. Skin contact may cause itching and/or redness, A

APR 22 *ss 11:43 FROM LGS RRDWASTE TO 8014062 PRGE.004/008 7

PR000CT NAME.: DEPOSI-TROL 855D EFFECTWE DATE: 29-AUG-1996 i

i

- ) FIRST AfD MEASURES 4

i SKIN CONTACT:

' Remove contaminated clothing. Wash exposed area with a large quantity of soap solution or water for 15 minutes, i

EYE CONTACT:

Immediately flush eyes with water for 15 minutes. Immediately j

contad a physician for additional treatment, j

INHALATION:

i Remove victim from contaminated area to fresh air. Apply i

appropriate first aid treatment as necessary.

I INGESTION:

l Do not feed anything by mouth to an unconscious or convulsive victim. Do not induce vomiting. Immediately contad physician j

Dilute contents of stomach using 3-4 glasses mik or wate.

5) FIRE FIGHTING MEASURES FIREFIGHTINGINS 30CTIONS:

Fire fighters should wear positive pressure self-contained breathing appertus (full facerpiece type).

i l

EXTINGUISHING MEDIA:

Dry chemical, carbon dioxide, foam or water.

j HAZARDOUS DECOMPOSITION PRODUCTS:

Thermal decomposition (destructive fires) yields elemental oxides.

l FLASH POINT:

l

> 200F P44(CC)-

l MISCELLANEOUS:

l Corroswo steel

[

UN1760, Emergency Response Guide #

e i

I

6) ACCIDENTAL RELEASE MEASURES i

j PROTECTION AND SPlLL CONTAINMENT:

Ventilate area. Use specified protodive equipm' sit. Caitain and i

absorb on absorbent material. Place in waste disposal container.

Flush area with water. Wet area may be slippery. Spread sand / grit.

DISPOSAL INSTRUCTIONS:

Water contaminated rda this product may be sent to a sanstery sewer i

treatment facility,in accordance with any local agreement,a permitted waste treatment faciisty or disdiarged under a permit Product L-as is - Inanerate or land dispose in an approved landfill.

t t

7) HANDLING AND STORAGE i

H A N nt Ih r,--

APR 22 '96.!! 43 FROM LGS RADUASTE TO 8014062 PAGE.005/008 PRODUCT NAME ; DEPOSI-TROL 855D EFFECTIVE DATE: 29-AUG-1995

8) EXPOSURE CONTROLS / PERSONAL PROTECTION EXPOSURE LIMITS CHEMICAL NAME TRADE SECRET INGREDIENT (E195);TSRN 125438 - 5118P

]

PEL (OSHA): NOT DETERMINED

]

TLV(ACGlH): NOT DETERMINED f

TRADE SECRET INGREDIENT (122);;TSRN 125438 - 5214P PEL (OSHA): NUISANCE DUST i

TLV (ACGlH): 5 MG/M3 MISC: Note: manufacturer's recommended exposure limit: 10 mg/m3.

J h

ENGINEERING CONTROLS:

Adequate ventilation to maintain air contaminants below exposure lirnits.

j PERSONAL PROTECTIVE EQUIPMENT:

Use protective equiprnent in accordance with 29CFR 1910 Subpart !

RESPIRATORY PROTECTION:

A respiratory protection program that meets OSHA's 29 CFR 1910.134 and ANSI Z88.2 requirements must be followed whenever workplace conditions warrant a respirator's use. Use air-

]

purifying respirators within use limitations associated with i

the equipment or else use supplied air fespirators, if air-i punfying resprator use is appropriate, use a respirator with dust / mist filters.

{

SKIN PROTECTION:

~

Neoprene gloves. Wash off after each use. Replace as j

i rwessary j

EYE PROTECTION:

}

Splash proof memical goggles.

I

9) PHYSICAL AND CHEMICAL PROPERTIES

}

Specific Grav. (70F) 1.070 Vapor Pressure (mmHG)

- 36.0

)

1 Freeze Point (F) 27.00 Vapor Density (air =1)

< 1.00 Viscosity (cps 70P) 9

% Solubility (water) 100.0 i

Odor Pungent Appearance Colorless To Green Physical State Liquid Flesh Point (F)

> 200 P-M(CC) pH As Is (approx. )

1.4 i

Evaporation Rate (Er.her=1)

< 1.00 4

h 3 Rfgk gg%p%N#t h IS kSO - sam 4 M m e a M S ** - **

L

APR 22 '96 11: 43 FROM LG5 RADWASTE-TO 8014062 PAGE.006/008 PRODUOT NAME : DEPOS-TROL 8550 EFFECTWE DATE: 29-AUG-1995 l

l

10) STABILITY AND REACTIVITY STABluTY:

Stable HAZARDOUS POLYMERIZATION:

VWil not occur.

INCOMPATIBluTIES:

May react with strong ox' izers.

d DECOMPOSIDON PRODUCTS:

Thermal decomposition (destructive fires) yields elemental oxides.

BETZ INTERNAL PUMPOUT/ CLEANOUT CATEGORIES:

4"

11) TOXICOLOGICAL INFORMATION l

i Oral LD50 RAT:

6,829 mg/kg Denral LD50 RABBIT:

>S,000 mg/kg l

NOTE - Estimated value

12) ECOLOGICAL INFORMATiON AQUATIC TOXICOLOGY Fathead Minnow 96 Hour Static Screen 0% Mortality: 1500 mg/L i

Daphnia magna 48 Hour Static Screen 0% Mortality: 1000 mga.

f j

BIODEGRADARON 4

No Data Available, s

l i

13) DISPOSAL CONSIDERATIONS i

i If this undiluted product is decarded as a waste, the US RCRA 1

hazarrious wasiciderN% lumberis :

[

D002= Corrosive (pH, steel).

Plesdk$ be advised; however, that state and local requrements for.

j waste deposal may be mone restnctive or otherwise ddarent from federal regulations. Consult state art:f local reA regarding the proper disposal of this material.

L

APR 22 '96 15 44 FROM LG5 RADWASTE TO 9014062 PAGE.007/008 PRODUCT NAME : DEPQSI-TROL 855D EFFECTIVE DATE: 29-AUG-1995 2

14) TRANSPORT INFORMATION DOT HAZARD:

Corrosive to steel UN / NA NUMBER:

UN1760 DOT EMERGENCY RESPONGE GUIDE #: Not applicable i

i

15) REGULATORY INFORMATION TSCA:

All components of this product are IUed in the TSCA inventory.

CERCLA AND/OR SARA REPORTABLE QUANTTTY(RQ):

11,224 gallons due to (122);

SARA SECTION 312 HAZARD CLASS:

immediate(acute); Delayed (Chronic)

{

SARA SECTION 302 CHEMICALS:

No regulated constituent present at OSHA th:ssholds i

SARA SECTION 313 CHEMICALS:

No regulated mnstituent present at OSHA thretholds 4

i CAllFORNIA REGULATORYINFORMATION CALIFORNIA SAFE DRINKING WATER AND TOXIC ENFORCEMENT ACT(PROPOSITION 65) CHEMICALS PRESENT:

No regulated constituent present at OSHA thresholds MICHIGAN REGULATORY INFORMATION No regulated constituent present at OSHA thresholds i

l 1

i t

+

APR 22 'SS 11244 FROM LOS RADWASTE TO 8014062 PAGE.008/008

. PRODUCT NAME ; DEPOSI-TROL 8550 EFFECTIVE DATE: 29-AU2-1995

16) OTHER INFORMATION NFPA/HMIS CODE TRANSLATION Health 2

Moderate Hazard Fire 1

Slight Hazard Reactivity 0

Minimal Hazard Special CORR DOT corrosive (1) Protective Equipment B

Goggles, Gloves (1) refer to section 8 of: CDS for additional protective equipment recommendations.

CHANGE LOG EFFECTIVE DATE REVISIONS TO SECTION:

SUPERCEDES MSDS status: 22-AUG-95 REVISED PORMAT i

i' i