PNO-I-86-075, on 860916,operators Removed Unit 1 from Svc to Repair Steam Leak on High Pressure Turbine Steam Return Line.Leak Caused by Steam Erosion on Section of 20-inch Pipe.Affected Section of Pipe Replaced

From kanterella
(Redirected from PNO-I-86-075)
Jump to navigation Jump to search
PNO-I-86-075:on 860916,operators Removed Unit 1 from Svc to Repair Steam Leak on High Pressure Turbine Steam Return Line.Leak Caused by Steam Erosion on Section of 20-inch Pipe.Affected Section of Pipe Replaced
ML20214P515
Person / Time
Site: Salem PSEG icon.png
Issue date: 09/18/1986
From: Norrholm L, Roxanne Summers
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To:
References
PNO-I-86-075, PNO-I-86-75, NUDOCS 8609230205
Download: ML20214P515 (1)


i I h DCS No: 50272860916 Data: September 18, 1986 PRELIMINARY NOTIFICATION OF EVENT OR UNUSUAL OCCURRENCE--PNO-I ) (I This preliminary notification constitutes EARLY notice of events of POSSIBLE safety er public interest significance. The information is as initially received without v;rification or evaluation, and is basically all that is known by the Region I staff on this date.

Facility: Licensee Emergency Classification:

Public Service Electric & Gas Company Notification of Unusual Event Salem Generating Station - Unit 1 Alert Hancocks Bridge, New Jersey Site Area Emergency D/N 50-272 General Emergency X Not Applicable

Subject:

UNPLANNED SHUTDOWN IN EXCESS OF 48 HOURS

'On September 16, 1986, at 9:13 p.m., operators removed Salem Unit I from service.to repair a steam leak on the high pressure turbine steam return line to the moisture separator / reheaters (MSR) and reheat steam system.

Return to service is not expected until September 21 or 22. The cause of the leak was determined to be steam erosion on a section of 20-inch pipe that connects to the 44-inch MSR piping. The licensee is replacing the affected section of pipe (approxima-tely 12 inches in length). Welding will require pre and post weld heat treatment. The licensee is also examining other' areas of piping for similar problems.

The resident inspector is following the licensee's actions.

Tha States of New Jersey and Delaware have been notified.

CONTACT: R. Summers L. Norrholm (215) 488-1115 (215) 488-1114 DISTRIBUTION: #

H. St. k MNBB Phillips E/W Willste Mail: ADM:DMB Chairman Zech ED0 NRR IE NMSS DOT:Trans only Comm. Bernthal PA OIA RES C:mm. Roberts ELD AE00 Comm. Asselstine Ctmm. Carr 7.'3 ;L ACRS Air Rights INP0----

SECY SP NSAC D L3 D CA PDR Regional Offices TMI Resident Section 3"3 b RI Resident Office Licensee: ~

(Reactor Licensees)

R2gion I Form 83 (Rev. July 1986) 8609230205 860918 9'$