Text

- _ _ _ - _

-

.

i

..

.

,

t U.S. NUCLEAR REGULATORY COMMISSION-

REGION I

Report No.

50-272/87-27 Docket No..50-272

?

License No,'DPR-70 Licensee:

Public Service Electric and Gas Company P. O. Box 236 Hancocks Bridge, New Jersey 08038 Facility.Name: Salem Generating Station, Unit 1 Inspection Ati Hancocks Bridge, New Jersey Inspection Conducted:

September 21-25, 1987J M

/0 o/f 7 Inspectors:henr1F.vanKessel,IReactorEngineer

-

.

.

date'

'

Approved by:

k. kdlo

/O e

8-

Dr. PT K. Eaperi, Chief, Special Test Programs date Section, EB, DRS Inspection Summary:

Routine Unannounced Inspection on September 21-25, 1987

,

(Inspection No. 50-272/87-27)

Areas Inspected:

Post Modification Test Program for.the forthcoming refueling j

' outage, including the Engineering Change (IEC) packages, the modification test

'

procedures, the Test Specifications and the schedule for installation.

Results:

No violations were identified, h

G

,

-

-

- _ - _ _ - _ _ _ _ _ _ _ _ _ -

J 3.

g;~ y l

'

DETAILS

!

h 1;-

Persons Contacted I

~ Public Service Electric and Gas Company L'

<0 Bhahnani,--Senior Staff Engineer L

R.LBaumert,. Senior Staff Engineer M..Danak', Senior Engineer -

M dray, Licens'.ng Engineer -

.

K.;Hedjar, Engineer

-

_

l

~L.-Fry,-Station Planning Manager

"

K. King,: Engineer

"

.T. Lutkehaus,~ Assistant to P&S. Manager i

M. Morroni, System Engineer

--

D.-Perkins, Manager Station QA G. Roggio, Licensing Engineer

, J.LSawhaney, Senior. Staff Engineer

'

_

J. W.> Zupko, -Jr.: General Manager Salem Operations

.

U.S.' Nuclear Regula' tory' Commission

,.

K. Halvey Gibson, Resident Inspector Salem 2.

Design Change and Modification Program The purpose 'of'this inspection was to assess the effectiveness of licensee's

activities 'to support' modifications and testing planned for the upcoming j

outage.

A number of design changes and modifications are planned for execution / installation during the forthcoming' refueling outage..The

!

' inspector randomly selected 10 modification packages for review. -These

-

packages are-identified in Attachment A.

Specifically, the inspector reviewed'the post. modification test specifications for adequacy and compliance with regulatory requirements.

It was noted that seven packages requi. red functional component tests.

Test procedures were not available

'for the three remaining modification packages.

The inspector identified the generic procedures to be used for the functional component tests. They are listed with the applicable work packages in i

Attachment A.

These generic procedures were used routinely for testing after maintenance or repair.

The system test procedures for IEC-2173,

'1890,land 2232, were not available in (PORC) approved form at the time of this infpection.

,

.

.

I

____

_ _ - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _.

.

.

In.the review of modification package IEC-2202 it was noted that the torque switch settings for the new Jamesbury valves (butterfly valves) of the emergency service water system will not be supplied by the vendor.

For that reason, the as found values will be used for torque switch setting.

However, the licensee did not establish the engineering basis for using the as found values.

This item remains unresolved pending licensee action to establish the engineering basis for the use of as-found values for the torque switch settings (Unresolved Item 87-27-01).

No violations or deviation.s were observed by the inspector during this review.

3.

Independent Inspection Effort The licensee recently installed Pulsation dampeners on the suction and discharge of the Charging Pump (reciprocating pump) of Salem-2.

Vibration data had been obtained at various points in the system, before and after the installation of the pulsation chambers.

These data showed a significant reduction in the pulsation pressure ripple typical for reciprocating pumps.

Piping fatigue failures had been experienced at both units as a result of the induced vibration in the piping.

',

Considering these favorable test results it was decided to install the same pulsation dampeners on the suction and discharge of the Charging Pump of Salem-1. The pulsation dampener for the discharge side will be installed during the forthcoming refueling outage.

If there is time available the suction side will be done as well.

The inspector noted that the test specifications for the Salem-1 instal-lations (IEC-2065) does not include a post modification vibration test as l

was done for Salem-2. The licensee decided not to include the test re-l quirement in the test specification based on the successful installation I

and testing of dampeners at Salem-2.

Upon identification of this concern

!

by the inspector a licensee representative informed the inspector that this vibration test will be done after completion of the installation and the test specification will be revised to include this requirement.

No violations or deviations were observed by the inspector.

4.

qA/QC Interface All of the test specifications in the modification packages listed in Attachment A were reviewed for QA interface requirements.

The installation specifications of the same packages were reviewed for QC interface requirement _ _ _ _ _ _ _. _ _ - - _

g;[e

'

r

,

4'

.-

,

It w'as found th'at the test specifications ano.their attached data' sheets '

all~had:provided space for.QA sign:off after'the' collection of test-data.

In all cases appropriate holdpoints and acceptance criteria were provided.- In the case of the installation specifications holdpoints and~

'signoff space-for QC also were provided.

No violations or deviations were observed by the inspector.

,

' 5;.

Plant Tours The inspector made several tours of the plant: including the control room, switchgear rooms, auxiliary building, service building, turbine building,_

and safeguards areas to observe work in progress, housekeeping and

_

cleanliness.

No unacceptable conditions were noted.

6.

Unresolved Items Unresolved items are matters'about which more information is required in Jorder to determine whether they are acceptable, an item of noncompliance,

'.

or a deviation. Two unresolved-items were identified, as discussed in section 2 of this report.

7.

Exit Interview At the conclusion of 'the site inspection, on September 25, 1987, an exit interview was conducted with the licensee's senior site representatives (denoted in Section 1) to discuss the findings.

.

At no time during this. inspection.was written material provided to the

-

-

. licensee by the inspector.

Based on the NRC Region I review of this

.

report and discussions held-with licensee representatives during this inspection, it was determined that this report does not contain information subject to 10 CFR 2.790 restrictions.

1

,

Lj d

q

-

n

,

.-

..

I

-

j

..

(

)

Attachment A Review of Modification Packages EC NO.

Description Type *

Proc. No. 1 or 2 2202 Pratt SW Valve Replacements FCT M-13-PTP-401, -202; IVP-502 for ISI i'

leak test.

2261 U Bolt Local Stress Problem N/A-Torque Verif. Program S-C-VAR-NFD-460 Rev. 2, 8-13-87, > 3" only.

1979 Eliminate Noise DC Relays FCT Later 2065

. Pulsation Dampener Charging Pump FCT Test Spec 87-N.018 I

M13-IVP-502 GEN 1914A Core Exit Thermocouple B/U Display FCT M13-PTP-202, 303 2173 ATWS Mitigation System Act. Gravity FCT&ST W (later)

1890 Modify T Hot + T Cold Indicators FCT&ST M13-PTP-201, 202, 303,

)

103

,

i 2210 Replace Type 12 CDF 22 Relays FCT W Doc SD2 for SA-1 i

Gen.'Diff. Relay for class IE applic.

2223 False Loads Power Suppl. in C Rod N/A None(NSR)

Cabinets 2232 Bottom Mounted Inst. System FCT&ST 5587-ICE-35303, Rev. O, CE Doc.,

l appr. 7-22-87

  • FCT, Functional Component Test; ST, System test.

i i

--- __-._-__.