CAROLINA POWER & LIGHT COMPANY BRUNSWICK STEAM ELECTRIC PLANT UNIT 0 ALTERNATE BORON INJECTION EMERGENCY OPERATING PROCEDURE:

E0P-01-LEP-03 VOLUME VI Rev. 003 FOR W O 0{,{,,y d##

y;t to te v"3 g3,e:wm ms**f.u-se nW

,,,,pcttst*"-

c;. su [?}f[,1 ce;.;s e.:TS-

,s u v : >

fA [7!*\\9 l/![ T[

Dates Approved By:

//

Gener&1 Manager /')

Manager - Operations 1 of 21 8811110146 091025 PDR ADOCK 05000324 P

f*DR

LIST OF EFFECTIVE PAGES E0P-01-LEP-03 Page(s)

Revision 1-21 3

l l

l l

l BSEP/VOL, VI/EOP-01-LEP-03 2 of 21 Rev. 3

[

1 A.

TITLE - Alternate Boron Injection B.

ENTRY CONDITION 1.

Boron injection is required AND the SLC system is NOT available.

2.

The SLC tank is empty and CANNOT be refilled AND further boron injection is required.

C.

OPERATOR ACTIONS 1.

INJECT boron with one or more of the following systems.

Selection

~

of system (s) used should be based upon system availability and accessibility.

a.

RWCU via SLC tank Section'1 on page 4.

l b.

RWCU with borax, Section 2 on page 9.

l c.

Condensate System, Section 3 on page 14.

l i

d.

HPCI/RCIC, Section 4 on page 18.

l e.

CRD. Section 5 on page 20.

I 2.

IF RWCU with borax OR Condensate System is used,'THEN NOTIFY Stores

~

~

To~ reman and Securit to coordinate delivery of borax to the chosen area.

BSEP/VOL. VI/EOP-01-LEP-03 3 of 21 Rev. 3

SECTION 1 - Boron Injection f rom RWCU via the SLC Tank 1.

IF reactor vessel level is being maintained below +112 inches OR

~~~

reactor vessel level was deliberately lowered, THEN BYPASS Group 3 isolation by installing the following jumpers:

a.

In Panel H12-P622, between Terminals 52 and 53 on Terminal

~~~

Board AA.

i b.

In Panel H12-P623, between Terminals 52 and 53 on Terminal Board AA.

i 2.

RESET Group 3 isolation.

3.

PLACE RWCU System in service with return to vessel.

(OP-14) i 4.

IF RWCU filters are in service, THEN NOTIFY the Control Room to open

~~'

FILTER BYPASS VLV, G31-F044, as necessary to maintain system flow.

5.

PLACE the filter flow controllers for both F/Ds to "MAN" and REDUCE

~~~

flow to a minimum.

6.

DEPRESS the HOLD START push button for both F/Ds.

7.

PLACE both F/Ds INFLUENT & EFFLUENT switch to "ISOLATE."

8.

CLOSE the following valves:

a.

F/D A Effluent Valve, G31-2002-AO-41A b.

F/D B Effluent Valve, G31-2002-AO-41B 9.

SELECT one F/D to fill with boron.

10.

OPEN or VERIFY OPEN the following valves for the selected F/D:

a.

T/D A(B) Drain Valve, G31-2002-AO-33A(B) b.

F/D A(B) Air Inlet / Vent Valve, G31-2002-AO-30A(B) c.

T/D A(B) Dome Drain Valve, G31-2002-AO-29A(B) d.

F/D A(B) Precoat Return Valve, G31-2002-AO-34A(B) e.

Precoat Pump Dischstge Isolation Valve, G31-Z002-15 f.

Air Inlet Valve, SA-V395 g.

Demineralized Water Supply to RWCU Isolation Valve. DW-V377 3

h.

T/D A(B) Precoat Supply Valve, G31-ZOO 2-AO-38A(B)

BSEP/VOL, VI/EOP-01-LEP-03 4 of 21 Rev. 3 I

i k

4 i.

Precoat Pump Seal Water Isolation Valve. DW-376 J.

Precoat Pump Suction Isolation Valve, 031-2002-55 CAUTION The backvash receiving tank will overflow at approximately 65%, resulting in high radiation levels around the RBEDT.

11.

For the selected F/D, PRESS the BACKWASH START push button and UOLD for 15 seconds Ojt until the red BACKWASH light stays on.

12.

OBSERVE the following automatic actions Depressurization of the selected F/D through automatic opening s.

of F/D A(B) Dome Drain Valve, C31-Z002-12A(B).

b.

The holding pump continues to run.

c.

F/D A(B) A0 Air Inlet Valve, C31-2002-13A(B), opens and liquid is ejected through the F/D A(B) Dome Drain Valve, C31-2002-12A(B).

d.

The dome drain closed and the F/D vessel is charged to 90 psig minimum air pressure.

e.

Holding pump A(B) stops and F/D A(B) Holding Pump Discharge Valve, C31-2002-14 A(B), closes.

f.

The contents of the F/D are rapidly forced to the BVRT by the high differential pressure created when F/D A(B) A0 Drain Valve, C31-Z002-8A(B), opens. This "bumps" the cake off the septums.

13. VMEN the F/D A(B) Precoat Return Valve, 031-Z002-10A(B) closes after completing its first bump, drain, rinse, and refill cycle; THEN PERFORM the following stepet s.

CLOSE Demineralized Water Supply To RWCU Isolation Valve, DW-V377.

b.

ALLOW the F/D to advance through the backwash cycle UNTIL the F/D sees into SHUTDOWN.

14 CLOSE the following valvest s.

F/D A(B) Drain Valve, C31-2002-AO-33A(B) b.

T/D A(B) Dome Drain Valve, 031-2002-AO-29A(B)

BSEP/VOL. VI/EOP-01-LEP-03 5 of 21 Rev. 3 l

j c.

T/D A(B) Precoat Return Valve, 031-Z002-AO-34A(B) d.

Air Inlet Valve, SA-V395

15. OPEN Precoat Tank Drain Valve To CRW, G31-2002-46.
16. WHEN the RWCU precoat tank is empty, THEN CLOSE C31-2002-46.
17. REMOVE the top hatch from the SLC tank.

NOTE The submersible pump is located in the LEP tool box on Reactor Building 80 foot east.

l

18. LOWER a submersible pump into the SLC tank.
19. ROUTE the discharge of the submersible pump to the RWCU precoat tank.

20.

START the submersible pump.

21. WHEN the RWCU precoat tank fills to the overflow pipe THEN STOP the submersible pump.
22. CLOSE the following valvest a.

REJECT TO COND VLV, G31-T034 b.

REJECT TO RADWASTE VLV, C31-P035

23. Manually OPERATE switches to OPEN the following valves:

a.

F/D A(B) A0 Done Vent Valve, 031-2002-7A(B).

b.

T/D A(B) A0 Precoat Supply Valve, C31-2002-11A(B).

, NOTE The ptacoat pump control switch is spring return to "AUTO."

The switch will have to be held in the "RAND" position for the pump to continue running.

24 PLACE the PREC0AT PUMP control switch to "RAND."

25. WHEN the precoat tank lov level annunciator alarms THEN PLACE the

~

YiiEC0AT PUMP control switch to "AUTO."

26. TILL the RWCU precoat tank from the SLC tank by REPEATING Steps 20 thru 25 UNTIL F/D A(B) is full as indicated by RWCU-FS-4869 (RWCU-FS-4871).

BSEP/VOL, VI/EOP-01-LEP-03 6 of 21 Rev. 3 l

27. OPERATE switches to CLOSE the following valves F/D A(B) A0 Precoat Supply Valve, G31-2002-11A(B) a.

b.

F/D A(B) A0 Dome Vent Valve, G31-2002-7A(B)

28. CLOSE the following valves:

F/D ALB) Precoat Supply Valve, G31-2002-AO-38A(B) a.

b.

F/D A(B) Air Inlet / Vent Valve C31-2002-AO-30A(B) c.

Precoat Pump Discharge Isolation Valve, G31-2002-15 29.

PLACE the F/D A(B) into "HOLD" by performing the following:

a.

SET the resin precoat timer to O minutes, b.

DEPRESS the PREC0AT START push button and HOLD for ten seconds OR UNTIL the red PREC0AT light comes on.

c.

ALLOW the F/D to advance through the precoat cycle.

30. PLACE F/D A(B) INFLUENT & EFFLUENT switch to "NORMAL.','
31. PRESS the FILTER START push button.
32. VHEN the F/D has pressurized to reactor pressure. THEN OPEN the F/D A(B) Effluent Valve, G31-2002-AO-41A(B).
33. NOTIFY Control Room to throttle FILTER RYPASS VLV G31-F044, as necessary to maintain system flov.
34. ADJUST the manual F/D flow controller to estabitsh 100 gpm flow through the f11ter.
35. MAINTAIN 100 gpm flow through the F/D for 10 minutes.

NOTE The F/D not being used may be backvashed while injecting boron with the in-service F/D.

36. REPEAT Sceps 4 through 35 of this section UNTIL:

a.

All control rods are fully inserted, 3 b.

E&RC saeples indicate boron concentration in reactor coolant is greater than 600 ppa, ej c.

The SLC tank is empty.

BSEP/VOL. VI/EOP-01-LEP-03 7 of 21 Rev. 3 f

I c

37.

IF the SLC tank is empty AND additional boron injection is required, TR2N RETURN to Section C E pare 3 of this procedure.

38. WHEN boron injection with the RWCU systeu is no longer required, l

YiIBI PERFORM the following stepst

~

I a.

NOTIFY Radvaste that the BVRT and RBEDT are potentially f

borated.

b.

RESTORE RWCU to the appropriate line-up per SOS.

l c.

NOTIFY E&RC to refill the SLC tank.

}

d.

IF jumpers were installed to bypass the Group 3 isolation, THEN lI IEMOVE the following jumperst

/

(1)

In Panel M12-7622, between Terminals 52 and 53 on Terminal InE Wr.

Board AA.

i i

/

(2)

In Panel H12-P6*t, between Terutnals 52 and 53 on Terminal l

InE Wr.

Board AA.

!'{

c k

[

f i

f f

f k

f f

I t.

i i

l I

i i

l 1

i l

BSEP/VOL. VI/EOP-01-LEP-03 8 ef 21 Rev. 3 l

9 SECTION 2 - Boron Injection with RWCU System Using Borax 1.

IF reactor vessel level is being maintained below +112 inches OR

~

reactor vessel level was deliberately lowered. THEN BYPASS Gro p 3 isolation by installing the following jumpers s.

In Panel H12-P622, between Terminals 52 and 53 on Terminal Board AA.

b.

In Panel H12-P623 between Terminals 52 and 53 on Terminal

~~"

Board AA.

i 2.

RESET Group 3 isolation.

3.

PLAUE RWCU System in service with return to vessel.

(OP-14) 4.

CLOSE the following valves:

a.

REJECT TO COND VLV. G31-F034 b.

REJECT TO RADWASTE VLV. G31-F035 5.

FILL the RWCU precoat tank to 75% vith demineralized water or fire.

water.

NOTE For a water temperature of 80'F. 250 pounds of borax is required for saturation.

If water temperature is more than 80*F. more borax is required for saturation.

If water temperature is less than 80'F. less borax is required for saturation.

Monitor the tank for undissolved borax to determine when the solution becomes saturated.

Boric acid may be used, in combination with borax, for pH control.

6.

START the RWCU precoat tank agitation and ADD borax to the precoat tank UNTIL the solution becomes saturated.

7.

IF RWCU filters are in service. THEN NOTIFY the Control Room to open FILTER BYPASS VLV. G31-F044, as necessary, to maintain system flow.

8.

PLACE the filter flow controllers for both F/Ds to "MAN" and REDUCE flow to minimum.

9.

DEPRESS the HOLD START push button on both F/Ds.

10. PLACE both F/Ds INFLUENT 6 EFFLUENT switch to "ISOLATE."

BSEP/VOL, VI/EOP-01-LEP-03 9 of 21 Rev. 3 l

i

11. CLOSE the following valves:

a.

F/D A Etfluent Valve, C31-2002-AO-41A i

b.

F/D 5 Effluent Valve, 031-2002-AO-41B I

12. SELECT one F/D to fill with boron.

~

t

13. OPEN or VERITY OPEN the following valves for the selected RWCU F/D:

l t

a.

F/D A(B) Drain Valve, C31-2002-AO-33A(B) l b.

F/D A(B) Air Inlet / Vent Valve. G31-Z002-AO-30A(B) c.

F/D A(B) Dome Drain Valve, G31-2002-AO-29A(B) d.

Precoat Return Valve, 031-Z002-AO-34A(B) l l

e.

F/D A(B) Precoat Pump Discharge Isolation Valve, G31-2002-15 f.

Air Inlet Valve. SA-V395 g.

Demineralized Water Supply To RWCU Isolation Valve. DW-V377 i

h.

F/D A(B) Prc. coat Supply Valve C31-2002-AO-38A(B) i.

Precoat Pump Seal Water Isolation Valve. DW-376 i

l j.

Precoat Pump Suction Isolation Valve. C31-2002-55

      • enen******eene********... eeeeeeeeeeeeeeeee*******ee********ene******enene CAUTION f

i The backwash receiving tank will overflow at approximately 65%, resulting in high radiation levels around the RBGT.

  • eenaseene******ene******ee****.en**eeeeee*********ee*****eeeeeeeeeeee**en****

[

l 14 For the selected F/D. PRESS the BACKWASH START push button and H01.D for 15 seconds 3 UNTIL the red BACKWASH light stays on.

15. OBSERVE the following automatic actionst a.

Depressurization of the selected F/D through automatic opening of F/D A(B) Dome Drain Valve G31-2002-12A(B) b.

The holding pump continues to run.

c.

F/D A(B) Air Inlet Valve. G31-2002-13A(B) opens and liquid is ejected through the F/D A(B) Dome Drain Valve. 031-ZOO 2-12A(B).

d.

The dome drain closes and the F/D vessel is charged to 90 psig minimum air pressure.

BSEP/VOL. VI/EOP-01-LEP-03 10 of 21 Rev. 3 l

l I

Holding Pump A(B) stops and F/D A(B) Holding Pump Discharge e.

Valve, C31-2002-14A(B), closes.

f.

The contents of the F/D are rapidly forced to the BVRT by the high dif ferential pressure created when F/D A(B) A0 Drain Valve, C31-2002-8A(B), opens quickly. This "bumps" the cake off the septums.

16. WHEN the F/D A(B) Precoat Return Valve, C31-2002-10A(B) closes af ter completing its first bump, drain, rinse, and refill cycle. THEN f

~

PERFORM the following stepst l

a.

CLOSE Domineralized Water Supply To RWCU Isolation Valve. DW-V377.

i b.

ALLOW the F/D to advance through the backwash cycle UNTIL the

~

F/D goes into "$HUTDOWN".

t

17. CLOSE the following valves a.

F/D A(B) Drain Valve, 031-Z002-AO-33A(B)

[

t b.

F/D A(B) Dome Drain Valve, G31-2002-AO-29A(B) f c.

F/D A(B) Precoat Return Valve, G31-ZOO 2-AO-34A(B) i i

d.

Air Inlet Valve. SA-V395 t

e.

REJECT TO COND VLV, G31-F034

{

f.

REJECT TO RADVASTE VLV, C31-T035 r

18. Manually OPERATE switches to open the following valves

[

t a.

F/D A(B) A0 Done Vent Valve, G31-Z002-7A(B)

I b.

F/D A(B) A0 Precoat Supply Valve, G31-2002-11A(B) t I

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeenenneenennene***neeeeeeeeeeeeemene***eneesee*

f CAUTION f

The precoat tank level vill rapidly decrease upon starting the precoat pump.

Adding water to the precoat tank should begin ismediately after starting the l

precoat pump.

einneenaanneeeeeeeeeeeeeeeeeeeeeee**eeneneenneneeseeeeeeeeeeeeeeeeeeeeeeme****

7 i

NOTE I

The precoat pump control switch is spring return l

to "AUTO."

The switch will have to be held in the "HAND" position for the pump to continue running.

i 19.

PLACE the PREC0AT PUMP control switch to "HAND."

BSEP/VOL. VI/EOP-01-LEP-03 11 of 21 Rev. 3 l

[

i f

20.

MAINTAIN the precoat tank level with dt:41neralized water or fire water.

21. WHIN the F/D is full as indicGed by RWCU-FS-4869 (RWCU-PS-4871),

THEN a.

PLACE the PREC0AT PUMP control switch to "AUTO."

b.

OPERATF. switches to close the following valves:

(1) F/D A(B) A0 Precoat Supply Valve, C31-2002-11A(B)

(2) F/D A(B) A0 Dome Vent Valve. C31-Z002-7A(B)

22. CLOSE the following valves:

a.

F/D A(B) Precoat Supply Valve, 031-2002-AO-38A(B) b.

F/D A(B) Air Inlet / Vent Valve C31-2002-AO-30A(B) c.

Precoat Pump Discharge Isolation valve, C31-2002-15 23.

PLACE the F/D A(B) into "HOLD" by performing the following:

a.

SET the resin precoat timer to 0 minutes.

b.

DEPRESS the PREC0AT START push button and HOLD for ten seconds 0_R UNTIL the red PREC0AT light comes on.

R c.

ALLOW the F/D to advance through the precoat cycle.

24 PLACE F/D A(B) INFLUENT and EFFLUENT switch to "NOPL".

25. PRESS the FILTER START push button.
26. WHEN the F/D has pressurized to reactor pressure. THEN OPEN the F/D A(B) Ef fluent Valve, C31-2002-41 A(B).

1 l

l

27. NOTIFY Control Room to throttle the FILTER BYPASS VLV, G31-T044, as necessary, to maintain system flow.

1 l

28. ADJUST the manual F/D flow controller to establish 100 spa flow through the filter.

l

29. MAINTAIN 100 spa flow through the F/D for ten minutes.

BSEP/VOL. VI/EOP-01-LEP-03 12 of 21 Rev. 3 l

l l

L

NOTE It will.equire approximately 2520 pounds of borax to obtain hot shutdown and 5030 pounds of borax to obtain cold shutdown.

30. REPEAT Steps 3 through 29 of this see. tion WTILt a.

All control rods are fully inserted. OR, b.

E&RC samples indicate boron concentration in reactor coolant is

~

greater than 600 ppe.

31. WEN boron injection with the RVCU system is no lonRer required, YlilN PERFORM the following stepet

~

a.

NOTIFT Radv ste that the BWRT and the RBEDT are potentially

]

borated.

j b.

RESTbRERWCUtotheappropriateline-uppertheSOS, c.

IF jumpers were installed to bypass the Group 3 isolation. THEN l

HM07E the following jumperst

/

(1)

In Panel H12-P622, between Terminals 52 and 53 en Terminal 3

InE W r.

Board AA.

j

/

(2)

In Panel M12-P623, between Terminals 52 and 53 on Teminal i

InE W r.

Loard AA.

i i

i 1

BSEP/vot. VI/EOP-01-LEP-03 13 of 21 Fev. 3 l

g ;g i 7tf ~

y

=

  • (,l'

./o SECTIQ 3 - 3oron Injection With' Condensate System 1.

CLOSE. Condensate Rejo t V21ve To Condensate Storage Tank,

~-

CO-LV-1-1.

OPEN CDD BYPASS VLV, CD-PV-401.

ISOLATE all CDDs.

4 OPEN SJAE Condensate Recirculation Valve, CO-TV-49-1 and CO-TV-49-2,

~

to maintain the condensato pomp discharge pressure between 150 and 190 psig.

5.

BYPASS one condensate booster pump as follows:

a.

TRIP all condensate booster pumps.

b.

REMOVE control power fuses from'the selected pump's 4KV breaker.

c.

PLACE the control switch for the selected pump in "AUTO."

d.

VERIFY the pump's discharge valve is open and the auxiliary oil pump is running.

6.

CLOSE the following valves:

a.

STARTUP LEVEL CONTROL VLV, FW-LIC-3269 b.

FEEDWATER RECIRC TO CONDENSER VLV, FW-FV-177 c.

FW-FV-177 ISOL VLV, FW-V10 7.

BYPASS the feedwater heaters and RFPs by OPENING the following valves:

j a.

FW HTRS 1 & 2 BYP VLV, COD-V183 b.

FW HTR 3A & 3B BYP VLV, COD-V186 c.

RFP.fPASS VLV, FW-V13 8.

ISOLATE feedwater heatecs and RF?s by CLOSING the following valves:

a.

RFP A SUCTION VI-V, COD-V49 t

.b.

RFP A DISCH VLV, FW-V3 c.

RFP B SUCTION VLV, COD-V50

{

d.

RFP B DISCH VLV, FW-V4 BSFP/VOL. VI/EOP-01-LEP-03 14 of 21 Rev. 3 i

HTR DRN COOLER A INLET VLV, COD-V181 e.

f.

HTR DRN COOLER B INLET VLV, COD-V182 g.

W HTR 2A OUTLET VLV, COD-V12 h.

FW HTR 2B OUTLET VLV, COD-V13 i.

FW HTR 3A INLET VLV, COD-V184 j.

FW HTR 3B INLET VLV, COD-V185 k.

FW HTR 3A OUTLET VLV, COD-V10 l.

FW HTR 33 OUTLET VLV, COD-V11 a.

FW HTR SA OUTLET VLV, W-V6 n.

FW HTR 5B OUTLET VLV, FW-V8 o.

FW HTR 4A INLET VLV, FW-Vil8 FW HTR 49 INLET VLV, FW-V119 p.

9.

VERIFY ON or START one condensate pump.

10.

IF a backwashcd CFD is NOT available,,Tj' N BACKWASH one CFD as follows:

a.

OPEN the following valves:

(1 Manual Vent Headec Isolation Valve, CFD-V427 (2) Manual Drain Header Isolation Valve, CFD-V428 b.

PLACE the VESSEL SELECTOR switch on the local control panel to the desired vessel.

PLACE the COMMON VESSEL CYCLE SELECTOR switch to "CLEAN."

c.

d.

PLACE the COMMON VESSEL CYCLE switch to "START."

e.

RUN the FILL timers to "O" minutes.

f.

WHEN the cycle complete alarm sounds, THEN the CFD is ready for a precoat.

11. PREC0AT the backwashed CFD with borax or boric acid as follows:

FILL the CFD precoat tank 75% with demineralized water or fire a.

water.

BSEP/VOL. VI/EOP-01-LEP-03 15 of 21 Rev. 3 l

l NOTE For a water temperature of-80'F, 400 pounds of borax is required for saturation.

If water temperature is more than 80*F more borax is required for saturation.

If water temperature is less than 80*F, less borax is required for saturation.

Monitor the tank for undis-solved borax to determine when the solution becomes saturated.

Boric acid may be used, in combination with borax, for pH control.

b.

START the agitator and ADP borax to the precoat tank UNTIL the solution becomes saturated.

c.

VERIFY or POSITION the VESSEL SELECTOR switch on the local

~~~

control panel to the backwashed CFD.

d.

POSITION the COMMON VESSEL CYCLE switch to "START."

e.

RUN all PILL timers to "0" minutes.

f.

CLOSE the Filter Demin A(B, C, D) Precoat Outlet And Backwash Inlet Valve, CFD-VWA(B, C, D).

g.

MAINTAIN precoat tank water level with the Condensate Supply To Precoat Tank Vent Valve, CFD-VP.

h.

WHEN the CFD is full (as indicated by CFD-PI-18,19, 20, or 21 reading equal to precoat pump discharge pressure), THEN perform the following steps:

(1) PLACE the Filter Demin A(B, C, D) Precoat Outlet And Backwash Inlet Valve, CFD-VWA(B, C D), to "AUT0".

(2) POSITION the PLACE IN STANDBY switch to "START."

12. OPEN STARTUP LEVEL CONTROL VLV, FW-LIC-3269.
13. CLOSE SJAE Condensate Recirculation Valves, CO-TV-49-1 and CO-TV-49-2, as required to ar.intain condensate pressure above reactor pressure.
14. PLACE the CFD that was precoated with borox or boric acid in service for at least 15 minutes.

BSEP/VOL. VI/EOP-01-LEP-03 16 of 21 Rev. 3 l

c NOTE It will require approximately 2520 pounds of-borax to obtain hot shutdown and approximately 5030 pounds of borax to obtain cold shutdown.

15.

REPEAT Steps 4 through 14 of this section UNTIL:

s.

All control rods are fully inserted, Olt b.

E&RC samples' indicate boron concentration is greater than 600 ppm.

16.

WHEN boron injection with the Condensate System is no longer required, THEN REALIGN the Condensate System as required for plant conditions.

(OP-32)

BSEP/VOL. VI/EOP-01-LEP-03 17 of 21 Rev. 3 l

SECTION 4 - Boron Injection With HPC1/RCIC l

1.

ESTABLISH a flow path from the SLC tank to HPCI/RCIC.. tion line as

~~~

follows:

a.

LOWER one end of a hose (stored in LEP tool box on 50 foot

~-"

elevation) from the 50 foot Reactor Building elevation through the southeast pipe chase to the -17 foot elevation, b.

CONNECT one end of the hose to the HPCI And RCIC CST Suction Vent Valve, CO-V301, and the other end tc 4he SLC tank drain line on the Reactor Building 50 foot elevation.

c.

OPEN HPCI And RCIC CST Suction Vent Valve, CO-V301.

d.

UNLOCK and OPEN SLC Pump Suction Header Drain Isolation Valve, C41-F015, (located 80 foot east elevation of Reactor Building).

.t************************************

CAUTION Djl NOT OPERATE HPCI or RCIC in CST recire while suction is aligned to SLC tank.

MINIMIZE operation with minimum flow valve open.

NOTE It is desirable to operate RCIC at the minimum flow necessary to maintain reactor vessel level in order to maximize boron injection concentration.

2.

START HPCI and/or RCIC as necessary to maintain reactor vessel level.

3.

IP the SLC tank level decreases to 0% AND additional boron injection is required, THEN RETURN to Section C on page 3 of this procedure.

(

l BSEP/VOL. VI/EOP-01-LEP-03 18 of 21 Rev. 3 l

1

l w

4.

ifs a.

ALL control rods are fully inserted, OR b.

E&RC samples indicate boron concentration is greater than 600 ppm, 0_RR c.

SLC tank level reaches 0%,

THEN PERFORM the following steps:

a.

CLOSE HPCI And RCIC CST Suction Vent Valve, CO-V301.

b.

CLOSE and LOCK CLOSED SLC Pump Suction Header Drain Isolation Valve, C41-F015.

c.

NOTIFY E&RC to refill the SLC tank.

d.

FLUSH the hoes used for boron injection as followsr (1) DISCONNECT the hose from the SLC tank drain line.

(2) CONNECT the hose to a demineralized water supply station.

(3) OPEN HPCI And RCIC CST Suction Vent Valve, CO-V301.

(4)

OPEN the demineralized water supply to flush hope for at least 15 minutes.

(5) CLOSE HPCI And RCIC CST Suction Vent Valve, CO-V301, and the demineralized water supply.

(6) REMOVE the hose and RETURN the hose to storage.

BSEP/VOL, VI/E0P-01-LEP-03 19 of 21 Rev. 3 l

l l

SECTION 5 - Boron Injection With CRD System l

,1.

ESTABLISH a flow path from the SLC tank to CRD Pumps suction as follows:

LOWER one end of a hose (stored in LEP tool box on 50 foot a.

elevation) from the 50 foot Reactor Building elevation through

~

the pipe chase to the CRD pump suction filters.

b.

CONNECT one end of the hose to Cordensate Supply Header Vent Valve, CO-V304, and the other end to the SLC tank drain line on the Reactor Building 50 foot elevation.

OPEN Condensate Supply Header Vent Valve, CO-V304.

c.

d.

UNLOCK and CLOSE the following valves:

(1) CRD Fuing A Recirculation Line Isolation Valve, C11(C12)-F015A (2) CRD Pump B Recirculation Line Isolation Vsive.

C11(C12)-F015B e.

UNLOCK and OPEN SLC Pump Suction Header Drain Isolation Valve, C41-F015 (located on Reactor Building 80 foot east elevation).

2.

IF annunciator CRD PUMP INLET FILTER AP HICH (A-5 6-1) alarms. THEN OPEN CRD Pump Suction Filter Byp0ss Valve, CO-V306.

l 3.

VERIFY ON or START one CRD pump.

4.

IF the SLC tank level decreases to 0% AND t.dditional boron injection is required, THEN RETURN to Section C on page 3 of this procedure.

5.

IF l

r a.

All control rods are fully inserted, E b.

E&RC samples indicate boron concentration is greater than 600 ppm,,0_R, c.

SLC tank level reaches 0%,

THDi PERFORM the following steps:

CLOSE Condensate Supply Header Vent Valve, Co-V304.

a.

b.

CLOSE and LOCK CLOSED SLC Pump Suction Header Drain Isolation Valve, C41-F015.

c.

NOTIFY E&RC to refill SLC tank.

BSEP/VOL. VI/EOP-01-LEP-03 20 of 21 Rev. 3 l

E' -

Y d.

OPEN and LOCK OPEN the following valves:

(1) CRD Pump A Recir:ulation Line Isolation Valve, C11(C12)-F015A (2) CRD Pump B Recircu*ation Line Isolation Valve, C11(Cl2)-F015B FLUSH the hose used for boron injection as follows:

e.

(1) utsCONNECT the hose from the SLC tank drain line.

(2) CONNECT the hose to a domineralized water supply station.

(3) OPEN Condensate Supply Header Vent Valve, Co-V304.

(4) OPEN the domineralized water supply to flush hose for at les=L 15 minutes.

(5) CLOSE Condensate Supply Header Vent Valve, Co-V304, end the oemineralized water supply.

(6) REMOVE the hose and RETURN the hose to storage.

i l

l l

BSEP/VOL. VI/EOP-01-LEP-03 21 of 21 Rev. 3 l

_______i____________.___________._____________-_._-._____________.______.___________

p-v

  • L CAROLINA POWER &' LIGHT COMPANY BRUNSWICK STEAM ELECTRIC PLANT UNIT 0 t

ALTERNATE BORON INJECTION EMERGENCY OPERATING PROCEDURE:

E0P-01-LEP-03 VOLUME VI Rev. 003 FOR INFO ONLY tests,sen1 aftt4*

Ri Not to te estd to perferm msintenance,m optratt or easip'Jit p!ut systswrits l

lf!AM Datet I[

Approved By:

A

[/

Gener&1 Manager /i Manager - Operatibns 1 of 21

~

\\

LIST OF EFFECTIVE PAGES

~

\\

i E0P-01-LEP-03 Page(s)

Revision 1-21 3

BSEP/VOL VI/EOP-01-LEP-03 2 of 21 Rev. 3

(

~

1 A.

TITLE - Alternate -Boron Injection l

B.

ENTRY CONDITION 1.

Boron injection is required AND the SLC system is NOT available.

2.

The SLC tank is empty and CANNOT be refilled AND furthsr boron injection is required.

C.

OPERATOR ACTIONS 1.

INJECT boron with one or more of the following systems.

Sele.cion cf pystem(s) used should be based upon system availability and accessibility.

s.

RWCU via SLC cank, Section 1 on page 4.

l' b.

RWCU with torax, Section 2 on page 9.

l c.

Condensate System, Section 3 on page 14.

l l

d.

HPCI/RCIC, Section 4 on page 18.

e.

CRD, Section 5 on page 20.

I 2.

IF RWCU with borax OR Condensate System is used, THEN NOTIFY Stores Foreman and Security to coordinate delivery of borax to the chosen

area, i

i i

L I

r i

h i

BSEP/VOL. VI/EOP-01-LEP-03 3 of 21 Rev. 3

SECTION 1 - Boron Injection from RWCU via the SLC Tank

'1.

IF reactor vessel level is being maintained below +112 inches OR

~

~~

reactor vessel level was deliberately lowered, THEN BYPASS Grou 3 isolation by installing the following jumpers:

a.

In Panel H12-P622, between Terminals 52 and 53 on Terminal

~""

Board AA.

i b.

In Panel H12-P623, between Terminals 52 and 53 on Terminal Board AA.

t 2.

RESET Group 3 isolation.

3.

PLACE RWCU System in service with return to vessel.

(OP-14) 4 IF RWCU filters are in service, THEN NOTIFY the Control Room to open FILTER BYPASS VLV, G31-F044, as necessary to maintain system flow.

5.

PLACE the filter flow controllers for both F/Ds to "MAN" and REDUCE

~~~

flow to a minimum.

6.

DEPRESS the HOLD START push button for both F/Ds.

7.

PLACE both F/Ds INFLUENT & EFFLUENT switch to "ISOLATE."

8.

CLOSE the following valves:

a.

F/D A Effluent Valve, G31-2002-AO-41A b.

F/D B Effluent Valve, G31-2002-AO-41B 9.

SELECT one F/D to fill with boron.

10.

OPEN or VERIFY OPEN the following valves, for the selected F/D:

s.

F/D A(B) Drain Valve, G31-2002-AO-33A(B) b.

F/D A(B) Air Inlet / Vent Valve, G31-ZOO 2-AO-30A(B) c.

F/D A(B) Dome Drain Valve, G31-2002-AO-29A(B) d.

F/D A(B) Precoat Return Valve, G31-2002-AO-34A(B) e.

Precoat Pump Discharge Isolation Valve, G31-ZOO 2-15 f.

Air Inlet Valve SA-V395 3.-

Domineralized Water Supply to RWCU Isolation Valve DW-V377 h.

F/D A(B) Precoat Supply Valve, G31-Z002-AO-38A(B)

BSEP/VOL, VI/EOP-01-LEP-03 4 of.21 Rev. 3

~

i.

Precoat Pump Seal Water Isolation Valve, DW-376 j.

Precoat Pump Suction Isolation Valve, 031-2002-55 CAUTICN The backwash receiving tank will overflow at approximately 65%, resulting in high radiation levels around the RBFDT.

11.

For the selected F/D, PRESS the BACKWASH START push button and HOLD

~~'

for 15 seconds oft until the red BACKWASH light stays on.

12.

OBSERVE the following automatic actions:

a.

Depressurization of the selected F/D through automatic opening

~~'

of F/D A(B) Dome Drain Valve, G31-ZOO 2-12A(B).

b.

The holding pump continues to run.

c.

F/D A(B) A0 Air Inlet Valve, G31-ZOO 2-13A(B), opens and liquid is ejected through the F/D A(B) Doce Drain Valve, 031-2002-12A(B).

d.

The dome drain closed and the F/D vessel is charged to 90 psig minimum air pressure.

e.

Holding pump A(B) stops and F/D A(B) Holding Pump Discharge Valve, G31-2002-14A(B), closes.

f.

The contents of the F/D are rapidly forced to the BWRT by the high differential pressure created when F/D A(B) A0 Drain Valve, G31-2002-8A(B), opens.

This "bumps" the cake off 'the septums.

13.

WHEN the F/D A(B) Precoat Return Valve, 031-2002-10A(B) closes after completing its first bump, drain, rinse, and refill cycle; THEN PERFORM the following steps:

s.

CLOSE Demineralized Water Supply To RWCU Isolation Valve DW-V377.

b.

ALLOW the F/D to advance through the backvash cycle UNTIL the F/D goes into SHUTDOWN.

14 CLOSE the following valves:

a.

F/D A(B) Drain Valve, G31-Z002-AO-33A(B) b.

F/D A(B) Dome Drain Valve, G31-Z002-AO-29A(B)

BSEP/VOL. VI/EOP-01-LEP-03 5 of 21 Rev. 3 l

c.

F/D A(B) Precoat Return Valve, G31-ZOO 2-AO-34A(B) d.

Air Inlet Valve, SA-V395

15. OPEN Precoat Tank Drain Valve To CRW, G31-2002-46.
16. WHEN the RWCU precoat tank is empty, THEN CLOSE G31-Z002-46.

17.

REMOVE the top hatch from the SLC tank.

NOTE The submersible pump is located in the LEP tool box on Reactor Building 80 foot east.

I 18.

LOWER a submersible pump into the SLC tank.

19.

ROUTE the discharge of the submersible pump to the RWCU precoat tank.

20.

START the submersible pump.

21.

WHEN the RkCU precoat tank fills to the overflow pipe, THEN STOP the submersible pump.

22.

CLOSE the following valvest a.

REJECT TO COND VLV, G31-F034 b.

REJECT TO RADWASTE VLV, G31-F035

23. Manually OPERATE switches to OPEN the following valves a.

F/D A(B) A0 Dome Vent Valve, G31-Z002-7A(B).

b.

F/D A(B) A0 Precoat Supply Valve, G31-2002-11A(B).

, NOTE The precost pump control switch is spring return to "AUTO."

The switch will have to be held in the "HAND" position for the pump to continue running.

24. PLACE the PREC0AT PUMP control switch to "RAND."
25. WHEN the precoat tank low level annunciator alarms, TWEN PLACE the

~

PREC0AT PUMP control switch to "AUTO."

i i

26.

FILL the RWCU precoat tank from the SLC tank by REPEATING Steps 20 t

thru 25 UNTIL F/D A(B) is full as indicated by RWCU43-4869 (RWCU-FS-4871).

j l

BSEP/VOL. VI/EOP-01-LEP-03 6 of 21 Rev. 3

-l

7 1

~

~27.

OPERATE switches to CLOSE the following valves:

a.

F/D A(5) A0 Precoat Supply Valve, G31-2002-11A(B)

~

b.

F/D A(B) A0 Dome Vent Valve, G31-2002-7A(B) l 28.

CLOSE the following valves:

~

a.

F/D A(B) Precoat Supply Valve, G31-2002-AO-38A(B) l b.

F/D A(B) Air Inlet / Vent Valve G31-2002-AO-30A(B)

[

[

c.

Precoat Pump Discharge Isolation Valve, G31-ZOO 2-15 r

29.

PLACE the F/D A(B) into "HOLD" by performing the following:

'I

[

a.

SET the resin precoat timer to 0 minutes.

b.

DEPRESS the PREC0AT START push button and HOLD for ten seconds i

OR UNTIL the red PREC0AT light comes'on.

~

i c.

ALLOW the F/D to advance through the precoat cycle.

l 30.

PLACE F/D A(B) INFLUENT & EFFLUENT switch to "NORMAL.'.'

31.

PRESS the FILTER START push button.

32. WHEN the F/D has pressurized to reactor pressure, THEN OPEN the F/D A(B) Effluent Valve, G31-2002-AO-41A(B).
33. NOTIFY Control Room to throttle FILTER BYPASS VLV, G31-F044, as necessary to maintain system flow.
34. ADJUST the manual F/D flow controller to establish 100 gpm flow through the filter.
35. MAINTAIN 100 spm flow through the F/D for 10 minutes.

NOTE The F/D not being used may be backwashed while injecting boron with the in-service F/D.

36.

REPEAT Steps 4 through 35 of this section UNTIL:

a.

All control rods are fully inserted, CR, b.

I4RC samples indicate boron concentration in reactor coolant is greater than 600 ppa,,0_RR c.

The SLC tank is septy.

BSEP/VOL. VI/EOP-01-LEP-03 7 of 21 Rev. 3

[

~

37.

IF the SLC tank is empty AND additional boron injection is required, TEEN RETURN to Section C on page 3 of this procedure.

~~

38. WHEN boron injection with the RWCU system is no longer required, I

~~

THEN PERFORM the following steps:

a.

NOTIFY Radwaste that the BWRT and RBEDT are potentially borated.

b.

RESTORE RWCU to the appropriate line-up per SOS.

c.

NOTIFY E&RC to refill the SLC tank, d.

IF jumpers were installed to bypass the Group 3 isolation, THEN ll REMOVE the following jumpers

/

(1)

In Panel H1?-P622, between Terminals 52 and 53 on Terminal In27 Yar.

Board AA.

__/__

(2)

In Panel H12-P623, between Terminals 52 and 53 on Terminal Ind. Ver.

Board AA.

i BSEP/VOL. VI/EOP-01-LEP-03 8 of 21 Rev. 3 l

SECTION 2 - Boron Injection with RWCU System Using Borax 1.

IF reactor vessel level is being maintained below +112 inches OR

~~~

reactor vessel level was deliberately lowered, THEN BYPASS Group 3 isolation by installing the following jumpers:

a.

In Panel H12-P622, between Terminals 52 and 53 on Terminal

~~~

Board AA.

b.

In Panel H12-P623, between Termintis 52 and 53 on Terminal

~~~

Board AA.

i 2.

. RESET Group 3 isolation.

3.

PLACE RWCU System in service with return to vessel.

(OP-14) 4 CLOSE the following valves:

a.

REJECT TO COND VLV, G31-F034 b.

REJECT !0 RADWASTE VLV, G31-F035 5.

FILL the RWCU precoat tank to 75% with demineralized water or fire.

water.

NOTE For a water temperature of 80*F, 250 pounds of borax is required for saturation.

If water temperature is more than 80'F, more borax is required for saturation.

If water temperature is less than 80'F, less borax is required for saturation.

Monitor the tank for undissolved borax to determine when the solution becomes satti?sted.

Boric acid may be used,1:i combination with borax, for pH control.

6.

START the RWCU precoat tank agitation and ADD borax to the precoat tank UNTIL the solution becomes saturated.

f.[ RWCU filters are in service. THEN NOTIFY the Control Room to open 7.

j FILTER BYPASS VLV, G31-F044, as necessary, to maintain system flow.

8.

PLACE the filter flow controllers for both F/Ds to "MAN" and REDUCE flow to minimum.

9.

DEPRESS the HOLD START push button on both F/Ds.

10.

PLACE both F/Ds INFLUENT & EFFLUENT switch to "ISOLATE."

BSEP/VOL. VI/EOP-01-LEP-03 9 of 21 Rev. 3 l

~

11.

CLOSE the following valves:

a.

F/D A Effluent valve, G31-ZOO 2-AO-41A b.

F/D B Effluent Valve, G31-2002-AO-41B 12.

SELECT one F/D to fill with boron.

13.

OPEN or VERIFY OPEN the following valves for the selected RWCU F/D:

a.

F/D A(B) Drain Valve, G31-2002-AO-33A(B) b.

F/D A(B) Air Inlet / Vent Valve, G31-2002-AO-30A(B) c.

F/D A(B) Dome Drain Valve, G31-2002-AO-29A(B) d.

Precoat Return Valve, 031-Z002-AO-34A(B) e.

F/D A(B) 2recoat Pump Discharge Isolation Valve, G31-2002-15 f.

Air Inlet Valve, SA-V395 g.

Demineralized Water Supply To RWCU Isolation Valve, DW-V377 h.

F/D A(B) Preceat Supply Valve, G31-ZOO 2-AO-38A(B) i.

Precoat Pump Seal Water Isolation Valve DW-376 j.

Precoat Pump Suction Isolation Valve, G31-Z002-55

  • 2****************************************************************************

CAUTION The backwash receiving tank will overflow at approximately 65%, resulting in high radiation levels around the RBEDT.

14.

For the selected F/D, PRESS the BACXWASH START push button and HOLD frr 15 seconde 0_R UNTIL the red BACKWASH light stays on.

R e

15.

OBSEh7E the following automatic actions:

a.

Depresa rization of the selected F/D through automatic opening of F/D A(B) Dome Drain Valve, G31-ZOO 2-12A(B) b.

The holding tump contiaues to run.

c.

F/D A(B) Air Inlet Valve, G31-2002-13A(B) opens and liquid is ejected through the F/D A(B) Dome Drain Valve, G31-2002-12A(B).

d.

The dome drain closes and the F/D vessel is charged to 90 psig minimum air pressure.

BSEP/VOL. VI/EOP-01-LEP-03 10 of 21 Rev. 3 l

f e.

Holding Pump A(B) stops and F/D A(B) Holding Pump Discharge Valve, G31-Z002-14A(B), closes.

f.

The contents of the F/D are rapidly forced to the BWRT by the high differential pressure created when F/D A(B) A0 Drain Valve, 031-ZOO 2-8A(B), opens quickly.

This "bumps" the cake off the septums.

16.

WHEN the F/D A(B) Precoat Return Valve, G31-2002-10A(B) closes af ter completing its first bump, drain, rinse, and refill cycle, THEN

~~~

PERFORM the following steps:

s.

CLOSE Demineralized Water Supply To RWCU Isolation Valve DW-V377.

b.

ALLOW the F/D to advance through the backwash cycle UNTIL the F/D goes into "SHUTDOWN".

17.

CLOSE the following valves:

s.

F/D A(B) Drain Valve, G31-2002-AO-33A(B) b.

F/D A(B) Dome Drain Valve, G31-2002-AO-29A(B) c.

F/D A(B) Precoat Return Valve, G31-2002-AO-34A(B) d.

Air Inlet Valve, SA-V395 e.

REJECT TO COND VLV, G31-F034 f.

REJECT TO RADWASTE VLV, G31-F035 18.

Manually OPERATE switches to open the following valves:

a.

F/D A(B) A0 Dome Vent Valve, G31-2002-7A(B) b.

F/D A(B) A0 Precoat Supply Valve, G31-Z002-11A(B)

CAUTION The precoat tank level will rapidly decrease upon starting the precoat pump.

Adding water to the precoat tank should begin immediately after starting the precost pump.

NOTE The precoat pump control switch is spring return to "AUTO."

The switch will have to be held in the "MAND" position for the pump to continue running.

19.

PLACE the PREC0AT PUMP control switch to "MAND."

BSEP/VOL. VI/EOP-01-LEP-03 11 of 21 Rev. 3 l

~

e 20.

MAINTAIN the precoat tank level with demineralized water or fire water.

21.

WHEN the F/D is full as indicated by RWCU-FS-4869 (RWCU-FS-4871),

THEN:

a.

PLACE the PREC0AT PUMP control switch to "AUTO."

b.

OPERATE switches to close the following valves:

(1)

F/D A(B) A0 Precoat Supply Valve, G31-ZOO 2-11A(B)

(2)

F/D A(B) A0 Dome Vent Valve, G31-Z002-7A(B) 22.

CLOSE the following valves:

a.

F/D A(B) Precoat Supply Valve, G31-ZOO 2-AO-38A(B) b.

F/D A(B) Air Inlet / Vent Valve, G31-2002-AO-30A(B) c.

Precoat Pump Discharge Isolation valve, G31-ZOO 2-15 23.

PLACE the F/D A(B) into "HOLD" by performing the following:

s.

SET the resin precoat timer to O minutes.

t b.

DEPRESS the PREC0AT START push button and HOLD for ten seconds

~~~

fyt UNTIL the red PREC0AT light comes on.

c.

ALLOW the F/D to advance through the precoat cycle.

24.

PLACE F/D A(B) INFLUENT and EFFLUENT switch to "NORMAL".

25.

PRESS the FILTER START push button.

l l

26.

WHEN the F/D has pressurized to reactor pressure, THEN OPEN the F/D A(B) Effluent Valve, G31-2002-41A(B).

27.

NOTIFY Control Room to throttle the FILTER BYPASS VLV, G31-F044, as i

necessary, to maintain system flow.

28.

ADJUST the manual F/D flow controller to establish 100 spm flow through the filter.

29.

MAINTAIN 100 spm flow through the F/D for ten minutes.

BSEP/VOL. VI/EOP-01-LEP-03 12 of 21 Rev. 3 l

_q - -

NOTE It will require approximately 2520 pounds of borax to obtain hot shutdown and 5030 pounds of borax to obtain cold shutdown.

i 30.

REPEAT Steps 3 through 29 of this section UNTIL:

s.

All control rods are fully inserted, Oft,

b.

E&RC samples indicate boron concentration in reactor coolant is

~~

greater than 600 ppe.

31. WHEN boron injection with the RWCU system is no longer required,

~~

THEN PERFORM the following steps:

s.

NOTIFY Radwaste that the BWRT and the RBEDT are potentially borated.

b.

RESTORE RWCU to the appropriate line-up per the SOS.

c.

IF jumpers were installed to bypass the Group 3 isolation, THEN l

IEMOVE the following jumpers

__/__

(1)

In Panel H12-P622, between Terminals 52 and 53 on Terminal Ind. Ver.

Board AA.

/

(2)

In Panel H12-P623, between Terminals 52 and 53 on Terminal Ind~ Wr.

Board AA.

~

BSEP/VOL. VI/EOP-01-LEP-03 13 of 21 Fev. 3 l

SECTION 3 - Boron Injection With' Condensate System 1.

CLOSE Condensate Reject Valve To Condensate Storage Tank,

~

CO-LV-1-1.

2.

OPEN CDD BYPASS VLV, CD-PV-401.

3.

ISOLATE all CDDs.

4.

OPEN SJAE Condensate Recirculation Valve, CO-TV-49-1 and CO-TV-49-2,

~

to maintain the condensate pump discharge pressure between 150 and 190 psig.

5.

BYPASS one condensate booster pump as follows:

a.

TRIP all condensate booster pumps.

b.

REMOVE control power fuses from the selected pump's 4KV breaker.

c.

PLACE the control switch for the selected pump in "AUTO."

d.

VERIFY the pump's discharge valve is open and the auxiliary oil pump is running.

6; CLOSE the following valves:

a.

STARTUP LEVEL CONTROL VLV, FW-LIC-3269 b.

FEEDWATER RECIRC TO CONDENSER VLV, FW-TV-177 c.

FW-FV-177 ISOL VLV, FW-V10 7.

BYPASS the feedwater heaters and RFPs by OPENING the following valves:

a.

FW HTRS 1 & 2 BYP VLV, COD-V183 b.

FW HTR 3A & 3B BYP VLV, COD-V186 c.

RTP BYPASS VLV, FW-V13 8.

ISOLATE feedwater heaters and RFPs by CLOSING the following valves:

a.

RFP A DISCH VLV, FW-V3 c.

RFP B SUCTION VLV, COD-V50 d.

RTP B DISCH VLV, FW-V4 BSEP/VOL. VI/EOP-01-LEF-03 14 of 21 Rev. 3

[

l

~

HTR DRN COOLER A INLET VLV, COD-V181 e.

f.

HTR DRN COOLER B INLET VLV, COD-V182 g.

W HTR 2A OUTLET VLV, COD-V12 h.

FW HTR 25 OUTLET VLV, COD-V13 i.

W HTR 3A INLLT VLV, COD-V184 l

j.

FW HTR 3B INLET VLV, COD-V185 k.

W HTR 3A OUTLET VLV, COD-V10 1.

FW HTR 3B OUTLET VLV, COD-V11 u.

FW HTR 5A OUTLET VLV, FW-/6 n.

FW HTR 5B OUTLET VLV, TW-V8 o.

FW HTR 4A INLET VLV, FW-Vil8 p.

FW HTR 45 INLET VLV, FW-V119 9.

VERIFY ON or START one condensate pump.

10.

IF a backwashed CFD is NOT available. THEN BACKWASH one CFD as follows:

a.

OPEN the following valves (1) Manual Vent Header Isolation Valve, CFD-V427 (2) Manual Drain Header Isolation Valve, CFD-V428 b.

PLACE the VESSEL SELECTOR switch on the local control panel to the desired vessel.

c.

PLACE the COMMON VESSEL CYCLE SELECTOR switch to "CLEAN."

d.

PLACE the COMMON VESSEL CYCLE switch to "START."

e.

RUN the FILL timers to "0" sinutes.

f.

WHEN the cycle complete alarm sounds, THEN the CFD is ready for a precoat.

11.

PREC0AT the backwashed CIV with borax or boric acid as follows:

FILL the C7V precoat tank 75% vith demineralized water or fire a.

water.

BSEP/VOL. VI/EOP-01-LEP-03 15 of 21 Rev. 3 l

t l

l 1

s NOTE For a water temperature of-80'F, 400 pounds of borax is required for saturation.

If water temperature is more than 80*F, more borax is required for saturation.

If water temperature is less than 80*F less borax is required for saturation.

Monitor the tank for undis-solved borax to determine when the solution becomes saturated.

Boric acid may be used, in combination with borax, for pH control.

b.

START the agitator and ADD borax to the precoat tank UNTIL the solution becomes saturated.

c.

VERITY or POSITION the VESSEL SELECTOR switch on the local

~~~

control panel to the backwashed CFD.

d.

POSITION the COMMON VESSEL CYCLE switch to "START."

e.

RUN all FILL timers to "0" minutes.

f.

CLOSE the Filter Demin A(B, C. D) Precoat Outlet And Backwash Inlet Valve, CFD-VVA(B, C, D).

3 MAINTAIN precoat tank water level with the Condensate Supply To Precoat Tonk Vent Valve, CFD-VP.

h.

WHEN.he CFD is full (as indicated by CFD-PI-18,19, 20, or 21 readf ag equal to precoat pump discharge pressure), THEN perform the tollowing oteps:

(1)

PLACE the Filter Domin A(B, C, D) Precoat Outlet And Backwash Inlet Valve, CFD-VVA(B, C, D), to "AUT0".

I (2)

POSITION the PLACE IN STANDBY switch to "START."

12.

OPEN STARTUP LEVEL CONTROL VLV, FW-LIC-3269.

13.

CLOSE SJAE Condensate Recirculation Valves, CO-FV-49-1 and CO-TV-49-2, as required to maintain condensate pressore above reactor pressure.

1 14.

PLACE the CFD that was precoated with borox or boric acid in service f

for at least 15 minutes.

I i

ll BSEP/VOL. VI/EOP-01-LEP-03 16 of 21 key. 3 1

s NOTE l

It will require approximately 2520 pounds of borax to obtain hot shutdown and approximately 5030 pounds of c..ax to obtain cold shutdown.

15.

REPEAT Steps 4 through 14 of this section UNTIL:

s.

All control rods are fully inserted, OJL b.

E&RC samples indicate boron concentration is greater than 600 ppa.

16.

WHEN boron injection with the Condensate System is no longer required, THEN REALIGN the Condensate System as required for plant conditions.

(OP-32)

BSEP/VOL. VI/ EOF-01-LEP-03 17 of 21 Rev. 3 l

o SECTION 4 - Bo'ron Injection With HPCI/RCIC l

1.

ESTABLISH a flow path from the SLC tank to HPCI/RCIC suction line as follows:

a.

LOWER one end of a hose (stored in LEP tool box on 50 foot

~~~

elevation) from the 50 foot Reactor Building elevation through the southeast pipe chase to the -17 foot elevation.

b.

CONNECT one end of the hose to the HPCI And RCIC CST Suction

~~~

Vent Valve, CO-V301, and the other end to the SLC tank drain line on the Reactor Building 50 foot elevation.

c.

OPEN HPCI And RCIC CST Suction Vent Valve, CO-V301.

d.

UNLOCK and OPEN SLC Pump Suction Header Drain Isolation Valve,

~~~

C41-F015, (located 80 foot east elevation of Reactor Building).

                                                                          • +4***************************************

i CAU ION DC NOT OPERATE HPCI or RCIC in CST re',li. shile suction is aligned to SLC tank. MINIMIZE operation with mi-laum flow valve open.

                                                                              • xe*************************************

F NOTE It is desirable to operate RCIC at the minimum flow necessary to maintain reactor vessel level in order tv maximize boron injection concentration.

2.

START HPCI and/or RCIC as necessary to maintain reactor vessel level.

3.

IF the SLC tank level decreases to 0% AND additional boron injection is required, THEN RETURN. to Section C on page 3 of this procedure.

LSEP/VOL. VI/E3P-01-LEP-03 18 of 21 Rev. 3 l

q.

a 4.

IF a.

ALL control rods are fully inserted, OR b.

E&RC samples indicate boron concentration is greater than

~

~

600 ppm,,0_RR c.

SLC tank level reaches 0%,

THEN PERFORM the following steps:

a.

CLOSE HPCI And RCIC CST Suction Vent Valve, CO-V301.

i b.

CLOSE and LOCK CLOSED SLC Pump Suction Header Drain Isolation

~

Valve, C41-F015.

c.

NOTIFY E&RC to refill the SLC tank.

d.

FLUSH the hose used for boron injection as followst'

{

(1) DISCONNECT the hose from the SLC tank drain line.

(2) CONNECT the hose to a domineralized water supply station.

(3) OPEN HPCI And RCIC CST Suction Vent Valve, Co-V301.

(4) OPEN the demineralized water supply to flush hose for at least 15 minutes.

(5) CLOSE HPCI And RCIC CST Suction Vent Valve, CO-V301, and

~

the domineralized water supply.

(6) REMOVE the hose and RETURN the hose to storage.

I l

I i

i l

l lf SSEP/VOL. VI/EOP-01-LEP-03 19 of 21 Rev. 3

s SECTION 5 - Boron Injection With CRD System l

1.

ESTABLISH a flow path from the SLC tank to CRD Pumps suction as follows:

a.

LOWER one end of a hose (stored in LEP tool box on 50 foot elevation) from the 50 foot Reactor Building elevation through the pipe chase to the CRD pump suction filters.

b.

CONNECT one end of the hose to Condensate Supply Header Vent Valve, Co-V304, and the other end to the SLC tank drain line on the Reactor Building 50 foot elevation.

c.

OPEN Condensate Supply Header Vent Valve, CO-V304.

d.

UNLOCK and CLOSE the following valves:

(1) CRD Pump A Recirculation Line Isolation Valve, C11(C12)-F015A (2) CRD Pump B Recirculation Line Isolation Valve, C11(C12)-F015B e.

UhLOCK and OPEN SLC Pump Suction Header Drain Isolation Valve, C41-F015 (located on Reactor Building 80 foot east elevation).

2.

IF annunciator CRD PUMP INLET FILTER AP HICH (A-5 6-1) alarus, THEN OPEN CRD Pump Suction Filter Bypass Valve, CO-V306.

3.

VERITY ON or START one CRD pump.

4 IF the SLC tank level decreases to 0% AND add aional boron injection is required, THEN RETURN to Section C on page 3 of this procedure.

I.

IF:

a.

All control rods are fully inserted E b.

E&RC samples indivete boron concentration is greater than 600 ppe, E c.

SLC tank level reaches 0%,

THDI PERFORM the following steps:

a.

CLOSE Condensate Supply Header Vent Valve, Co-V304.

b.

CLOSE and LOCK CLOSED StC Pump Suction Header Drain Isolation Valve, C41-F013.

c.

NOTIFY E&RC to refill SLC tank.

SSEP/VOL. V1/EOP-01-LEP-03 20 of 21 Rev. 3 l

.P o..

d.

Ol'EN and LOCK OPEN the following valvest (1) CRD Pump A Recirculation Line Isolation Valve, C11(C12)-F015A (2) CRD Pump B Recirculation Line Isolation Vaive, i

i C11(C11)-F0158 e.

FLUSH the hose used for boron injaction as follows:

i (1) DISCONNECT the hose from the SLC tank drain line.

(2) CONNECT the base to a domineralized water supply station.

t (3) OPEN Condensate Supply Header Vent Valve, CO-V304.

(4) OPEN the domineralized water supply to flush hose for at least 15 minutes.

(5) CLOSE Condensate Supply Header Ven'. Val' CC-i304, and the domineralized water suppt,y.

i (6)

REMOVE thw hose and RETURN the hose to starage.

~

r i

h Y

f I

f l

i t

L i

I i

BSEP/VOL. VI/EOP-01+LEP-03 21 of 21 Rev. 3 l