MONTHYEARML20212J9991999-10-0101 October 1999 Responds to Recent Ltr to President Clinton,H Clinton, Chairman Jackson &/Or Wd Travers Expressing Concern Re Millstone Npps.Nrc Continues to Monitor Performance of Plant to Ensure That Public Health & Safety Adequately Protected ML20212L1831999-10-0101 October 1999 Responds to Recent Ltr to Wd Travers Expressing Concerns Re Millstone NPPs & Continued Lack of Emergency Mgt Plan for Eastern Long Island.Nrc Continues to Monitor Performance of Millstone to Ensure Adequate Protection to Public Health ML20212L2081999-10-0101 October 1999 Responds to Recent Ltrs to President Wj Clinton,Chairman Jackson & Commissioners & Wd Travers,Expressing Concerns Re Millstone NPPs & Continued Lack of Mgt Plan for Eastern Long Island.Nrc Continues to Monitor Plant Performance ML20212L2171999-10-0101 October 1999 Responds to Recent Ltr to President Wj Clinton,Chairman Jackson & Commissioners,Wd Travers & Ferc,Expressing Concerns Re Millstone NPPs & Continued Lack of Emergency Mgt Plan for Eastern Long Island ML20212L1971999-10-0101 October 1999 Responds to Recent Ltr to Chairman Jackson & Commissioners Expressing Concerns Re Millstone NPPs & Continued Lack of Emergency Mgt Plan for Eastern Long Island.Nrc Continues to Monitor Plant Performance to Ensure Public Health & Safety ML20212K1241999-10-0101 October 1999 Responds to Recent Ltrs to Chairman Jackson,Commissioners & Wd Travers,Expressing Concern Re Millstone Npps.Nrc Continues to Monitor Performace of Millstone to Ensure That Public Health & Safety,Adequately Protected ML20112E8911996-05-24024 May 1996 FOIA Request to Inspect & Copy Original OL Issued by Aec/Nrc for Util & EPP Issued as App B to Plant OL SNRC-2192, Forwards Both Copies,Signed by Util President Cv Giacomazzo, of Amend 7 to Indemnity Agreement B-87.Util Returning Copies Because Effective Date Left Blank1995-05-15015 May 1995 Forwards Both Copies,Signed by Util President Cv Giacomazzo, of Amend 7 to Indemnity Agreement B-87.Util Returning Copies Because Effective Date Left Blank ML20082B9131995-03-13013 March 1995 Submits Corrected Page for Insertion Into Final Rept Re Confirmatory Survey of RB & Phase 4 Systems at Plant ML20081A9321995-03-0707 March 1995 Forwards Final Rept Orise 95/B-81, Confirmatory Survey of Reactor Bldg & Phase 4 Sys Shoreham Nuclear Power Station Brookhaven,Ny ML20081A6531995-03-0707 March 1995 Forwards Final Rept Orise 95/B-80, Confirmatory Survey of Radwaste Bldg,Suppression Pool,Phase 2 Phase 3 Sys,Shoreham Nuclear Power Station,Brookhaven,Ny ML20081A6841995-02-21021 February 1995 Forwards Final Rept Confirmatory Survey of Radwaste Bldg, Suppression Pool,Phase 2 & Phase 3 Sys,Shoreham Nuclear Power Station,Brookhaven,Ny ML20081B5801995-02-21021 February 1995 Forwards Final Rept Confirmatory Survey of Reactor Bldg & Phase 4 Sys Shoreham Nuclear Power Station Brookhaven,Ny ML20081A7001995-01-30030 January 1995 Forwards Rev 1 to Draft Rept Confirmatory Survey of Radwaste Bldg,Suppression Pool,Phase 2 & Phase 3 Sys, Shoreham Nuclear Power Station,Brookhaven,Ny ML20081A7111995-01-30030 January 1995 Forwards Rev 1 to Draft Rept Confirmatory Survey of Reactor Bldg & Phase 4 Sys,Shoreham Nuclear Power Station, Brookhaven,Ny SNRC-2189, Forwards Shoreham Nuclear Power Station Radiological Environ Monitoring Program,Annual Radiological Environ Operating Rept, Jan-June 19941995-01-20020 January 1995 Forwards Shoreham Nuclear Power Station Radiological Environ Monitoring Program,Annual Radiological Environ Operating Rept, Jan-June 1994 SNRC-2188, Responds to NRC Request for Addl Info Re Certain Elevated Levels Found During Phase 4 Confirmatory Survey1995-01-20020 January 1995 Responds to NRC Request for Addl Info Re Certain Elevated Levels Found During Phase 4 Confirmatory Survey SNRC-2187, Forwards Snps Annual Man-Rem Rept, Including Individuals for Whom Personnel Monitoring Provided During CY94,per 10CFR20.407(a) & (B).Rept Also Includes Individuals Identified in 10CFR20.202(a),who Require Monioring1995-01-11011 January 1995 Forwards Snps Annual Man-Rem Rept, Including Individuals for Whom Personnel Monitoring Provided During CY94,per 10CFR20.407(a) & (B).Rept Also Includes Individuals Identified in 10CFR20.202(a),who Require Monioring SNRC-2182, Forwards Final Annual Radioactive Effluent Release Rept for Cy 1994, Including Last Revised Copies of ODCM & Pcp.Rept Prepared for Closeout Purposes as Part of Completion of Plant Decommissioning1994-11-0101 November 1994 Forwards Final Annual Radioactive Effluent Release Rept for Cy 1994, Including Last Revised Copies of ODCM & Pcp.Rept Prepared for Closeout Purposes as Part of Completion of Plant Decommissioning ML20077L3331994-10-25025 October 1994 Forwards Revised Proposed Confirmatory Survey Plan for Reactor Bldg Shoreham Nuclear Power Station Brookhaven,Ny ML20076K3881994-10-20020 October 1994 Forwards Proposed Confirmatory Survey Plan for Reactor Bldg, Shoreham Nuclear Power Station,Brookhaven,Ny,For Review & Comment ML20077M8351994-10-20020 October 1994 Forwards Draft Rept, Confirmatory Survey of Radwaste Bldg, Suppression Pool & Phase 2 Systems,Shoreham Nuclear Power Station,Brookhaven,Ny SNRC-2184, Forwards Shoreham Decommissioning Project Termination Survey Final Rept Phase 4. Portions Withheld1994-10-12012 October 1994 Forwards Shoreham Decommissioning Project Termination Survey Final Rept Phase 4. Portions Withheld SNRC-2185, Summarizes Results from Revised Exposure Pathway Analysis Using Corrected Dcf for External Exposure for Cs-137.Rev 1 to Analysis of Bulk Matl Reconcentration Potential & Possible Exposure Pathways Encl1994-10-0404 October 1994 Summarizes Results from Revised Exposure Pathway Analysis Using Corrected Dcf for External Exposure for Cs-137.Rev 1 to Analysis of Bulk Matl Reconcentration Potential & Possible Exposure Pathways Encl ML20076F9251994-09-26026 September 1994 Forwards Final Rept Orise 94/I-80, Confirmatory Survey of Turbine Bldg,Site Grounds & Site Exteriors Shoreham Nuclear Power Station Brookhaven,Ny SNRC-2183, Forwards Amend 6 to Indemnity Agreement B-871994-09-23023 September 1994 Forwards Amend 6 to Indemnity Agreement B-87 SNRC-2181, Notifies of Equipment Changes to Shoreham Facility Which Have Occurred Subsequent to Rept on Phase I Final Survey Status,Provided in Util .Equipment Changes Described in Encl Table 11994-09-14014 September 1994 Notifies of Equipment Changes to Shoreham Facility Which Have Occurred Subsequent to Rept on Phase I Final Survey Status,Provided in Util .Equipment Changes Described in Encl Table 1 SNRC-2180, Forwards 940829 Memo Entitled, Technical Evaluation of Dusting from Concrete Blocks, Addressing Issue Discussed in Insp Rept 50-332/94-021994-09-0101 September 1994 Forwards 940829 Memo Entitled, Technical Evaluation of Dusting from Concrete Blocks, Addressing Issue Discussed in Insp Rept 50-332/94-02 SNRC-2179, Proposes That Release Criterion for Soil Be Applied to Certain Other Bulk Matls Which Will Remain at Plant Upon Completion of Decommissioning.Analysis of Bulk Matl Reconcentration Potential & Possible Exposure Pathways Encl1994-09-0101 September 1994 Proposes That Release Criterion for Soil Be Applied to Certain Other Bulk Matls Which Will Remain at Plant Upon Completion of Decommissioning.Analysis of Bulk Matl Reconcentration Potential & Possible Exposure Pathways Encl SNRC-2178, Forwards Proprietary Response to NRC Concerns Re Survey Instruments Used for Termination Survey.Extensive Discussion Provided in Interest of Rapidly Bringing Outstanding Concerns to Close.Response Withheld (Ref 10CFR2.790(a)(4))1994-08-17017 August 1994 Forwards Proprietary Response to NRC Concerns Re Survey Instruments Used for Termination Survey.Extensive Discussion Provided in Interest of Rapidly Bringing Outstanding Concerns to Close.Response Withheld (Ref 10CFR2.790(a)(4)) ML20072P1591994-08-17017 August 1994 Forwards Revised, Confirmatory Survey Plan for Radwaste Bldg & Suppression Pool for Plant SNRC-2176, Informs of near-term Completion of Decommissioning of Shoreham Nuclear Power Station & Hereby Respectfully Requests Support in Achieving Timely Termination of Facility possession-only License NPF-821994-08-0404 August 1994 Informs of near-term Completion of Decommissioning of Shoreham Nuclear Power Station & Hereby Respectfully Requests Support in Achieving Timely Termination of Facility possession-only License NPF-82 SNRC-2177, Forwards Rev 3 to Shoreham Decommissioning Project Termination Survey Plan. Portions of Rept Withheld1994-08-0404 August 1994 Forwards Rev 3 to Shoreham Decommissioning Project Termination Survey Plan. Portions of Rept Withheld ML20071L8741994-07-29029 July 1994 Forwards Confirmatory Survey Plan for Radwaste Building & Suppression Pool for Review & Comment SNRC-2175, Provides Notification of Survey Location Changes to Shoreham Facility Which Have Occurred Subsequent to Repts on Phases 1,2 & 3 Final Survey Status Provided in Refs 1,2 & 3 Respectively1994-07-18018 July 1994 Provides Notification of Survey Location Changes to Shoreham Facility Which Have Occurred Subsequent to Repts on Phases 1,2 & 3 Final Survey Status Provided in Refs 1,2 & 3 Respectively SNRC-2173, Forwards Termination Survey Final Rept Phase 3. Proprietary Pages to Rept Also Encl.Proprietary Pages Withheld (Ref 10CFR2.790)1994-06-14014 June 1994 Forwards Termination Survey Final Rept Phase 3. Proprietary Pages to Rept Also Encl.Proprietary Pages Withheld (Ref 10CFR2.790) SNRC-2172, Certifies That All SNM as Irradiated Fuel Permanently Removed from Site & That Decommissioning/Decontamination Work on Biological Shield Wall Complete,In Accordance W/Nrc Approving Amend 11 to Pol NPF-821994-06-0707 June 1994 Certifies That All SNM as Irradiated Fuel Permanently Removed from Site & That Decommissioning/Decontamination Work on Biological Shield Wall Complete,In Accordance W/Nrc Approving Amend 11 to Pol NPF-82 SNRC-2171, Submits Resolution of Items Identified by NRC Region I Project Inspector,Pertaining to Planned Final Draindown & Discharge of Spent Fuel Storage Pool,Following Complete Removal of Irradiated Fuel1994-06-0202 June 1994 Submits Resolution of Items Identified by NRC Region I Project Inspector,Pertaining to Planned Final Draindown & Discharge of Spent Fuel Storage Pool,Following Complete Removal of Irradiated Fuel SNRC-2170, Requests Approval of Proposed Change to Shoreham Decommissioning Plan for Addl Remedial Decontamination of Shoreham Spent Fuel Storage Pool Beyond That Originally Specified in Decommissioning Plan1994-05-20020 May 1994 Requests Approval of Proposed Change to Shoreham Decommissioning Plan for Addl Remedial Decontamination of Shoreham Spent Fuel Storage Pool Beyond That Originally Specified in Decommissioning Plan SNRC-2168, Notification to NRC of Transfer of Device Containing 30 Uci Cs-137 Source.Device Transferred to JW Merkel,Terra Analytics,Inc1994-05-13013 May 1994 Notification to NRC of Transfer of Device Containing 30 Uci Cs-137 Source.Device Transferred to JW Merkel,Terra Analytics,Inc SNRC-2169, Advises of Listed Clarification to Util Re Resignation of Jc Brons from Position of Executive Vice President of Shoreham Decommissioning Project1994-05-11011 May 1994 Advises of Listed Clarification to Util Re Resignation of Jc Brons from Position of Executive Vice President of Shoreham Decommissioning Project ML20029E1731994-05-11011 May 1994 Informs That Based on Recent Discussions Between Officials, Licensee Decided to Retain Organizational Position at Least Until Fuel Removed from Site ML20029D1991994-04-29029 April 1994 Forwards Shoreham Nuclear Power Station Radiological Environ Monitoring Program Annual Radiological Environ Operating Rept Jan-Dec 1993. ML20029D2571994-04-28028 April 1994 Advises That Jc Brons Resigned to Pursue Employment W/ Another Util Co,Effective 940429 ML20029C7111994-04-22022 April 1994 Submits Technical Info on Biological Shield Wall Blocks to Be Surveyed SNRC-2163, Provides Notification of Equipment Changes to Facility Which Have Occurred Subsequent to Report on Phase I Final Survey Status Provided in Util1994-04-21021 April 1994 Provides Notification of Equipment Changes to Facility Which Have Occurred Subsequent to Report on Phase I Final Survey Status Provided in Util ML20065M3701994-04-20020 April 1994 Responds to NRC Verbal Request for Info Re Estimated Cost for Decommissioning SNRC-2161, Forwards 1994 Internal Cash Flow Projection for Shoreham Nuclear Power Station1994-03-30030 March 1994 Forwards 1994 Internal Cash Flow Projection for Shoreham Nuclear Power Station SNRC-2160, Forwards Financial Info Required by 10CFR50.71(b)1994-03-30030 March 1994 Forwards Financial Info Required by 10CFR50.71(b) SNRC-2148, Forwards Info Supporting Licensee Proposed Amend,Submitted on 941104.Specifically,info Supports Estimates & Conclusions Re Small Quantity of Remaining Radioactive Matl & Low Radiological Significance of Potential Accident Releases1994-03-0808 March 1994 Forwards Info Supporting Licensee Proposed Amend,Submitted on 941104.Specifically,info Supports Estimates & Conclusions Re Small Quantity of Remaining Radioactive Matl & Low Radiological Significance of Potential Accident Releases 1999-10-01
[Table view] Category:NRC TO UTILITY
MONTHYEARML20058J0591990-11-19019 November 1990 Forwards NRC Public Notice of 901108 License Amend Request Re Shipment of Fuel Support Pieces to Low Level Radwaste Disposal Repository at Barnwell,Sc ML20058H8091990-11-14014 November 1990 Responds to Indicating Desire to Ship 137 Fuel Support Castings & 12 Peripheral Pieces to Low Level Radwaste Repository ML20062B6631990-10-12012 October 1990 Extends Invitation to Attend 910220-21 Util Symposium/ Workshop in King of Prussia,Pa Re Engineering Role in Plant Support ML20059M7901990-09-27027 September 1990 Advises That 880708 Response to NRC Bulletin 88-004 Re Potential safety-related Pump Loss Acceptable ML20059M4991990-09-20020 September 1990 Forwards Insp Rept 50-322/90-02 on 900606-0825.No Violations Noted ML20056B4481990-08-21021 August 1990 Forwards Exemption from fitness-for-duty Requirements Re 10CFR26,per .Exemption Requested to Limit Scope of Program to Persons W/Unescorted Access to Area Containing Equipment Necessary to Support & Maintain Storage of Fuel ML20059A6491990-08-16016 August 1990 Grants Waiver of Compliance from Limiting Condition for Operation 3.7.1.2.b.3 of Tech Spec on Plant Svc Water Sys, Per 900810 & 15 Ltrs.Waiver Allows Performance of Underwater Radiation Survey & Physical Insp of Selected Fuel Elements ML20059A6351990-08-15015 August 1990 Forwards Notice of Consideration of Issuance of Amend to License NPF-82 & Proposed NSHC Determination & Opportunity for Hearing Re 900105 Application ML20059A7151990-08-14014 August 1990 Expresses Appreciation for Remarks on Status & Schedules During drop-in Visit at Region I on 900731.Summary of Discussion Encl ML20058N8391990-08-13013 August 1990 Forwards Environ Assessment & Finding of No Significant Impact Re 900315 Request for Exemption from Full Scope of Fitness for Duty Requirements of 10CFR26 ML20058P1921990-08-0707 August 1990 Forwards Insp Rept 50-322/90-03 on 900710-13.No Violations Noted.One Unresolved Item Noted ML20058M5951990-08-0606 August 1990 Discusses Licensee Engineering Initiatives.Encourages Initiation of Initiative Similar to Region V Licensees Establishment of Engineering Mgrs Forum to Foster Disciplined & Coordinated Approach to Initiatives ML20056A1971990-07-31031 July 1990 Forwards Amend 6 to License NPF-82,safety Evaluation,Notice of Issuance & Exemption Re Defueled Emergency Preparedness License Condition.Proposed Changes Would Allow Util to Cease Offsite Emergency Preparedness Activities ML20055G5691990-07-19019 July 1990 Grants Util 15-day Extension of 900619 Waiver of Compliance Re OL Paragraph 2.C.(13) Quarterly Drills License Condition. Extension Will Allow NRC to Complete Review of Associated Request to Cease Offsite Emergency Preparedness Activities ML20055D2911990-06-27027 June 1990 Forwards Review of Util 900105 Request to Amend Tech Specs to Reflect Plant Protracted Defueled Condition.Meeting Should Be Scheduled at Site on 900719 & 20 to Discuss Finalizing Plant Defueled Tech Specs ML20055E3591990-06-25025 June 1990 Forwards Amend 5 to License NPF-82 & Safety Evaluation.Amend Changes Administrative Section of Tech Specs & Moves Procedural Details Involving Radioactive Effluent Monitoring Instrumentation & Equipment Requirements to ODCM ML20055C8281990-06-19019 June 1990 Grants 900530 Request for Waiver of Compliance from License NPF-82,Paragraph 2.C.(13) Re Quarterly Drills License Condition,Pending NRC Action on 891215 Request to Cease Offsite Emergency Preparedness Activities ML20248C0531989-09-26026 September 1989 Forwards Amend 4 to Indemnity Agreement B-87,reflecting Changes to 10CFR140.Amend Reflect Increase in Primary Layer of Nuclear Energy Liability Insurance Provided by ANI & Maelu ML20248G9331989-09-25025 September 1989 Forwards Safeguards Insp Rept 50-322/89-08 on 890821-24.No Violations Noted ML20247L3011989-09-15015 September 1989 Forwards J Mcgranery & L Bickwit 10CFR2.206 Petitions & Suppls & Requires,Under 10CFR50.54 (F) Provisions,That Licensee Address Each Concern Raised within 30 Days of Ltr Receipt ML20246K8301989-08-30030 August 1989 Requests to Provide NRC W/Written Commitment to Assure That Items Listed Satisfied for Extended Period & to Provide Info Re Processes Followed in Selecting Operating Status & in Determining Intended Staffing Changes,Per 890630 Commitment ML20246J3341989-08-18018 August 1989 Clarifies NRC Position Re Definition of Extremity for Purpose of Setting Occupational Exposure Limits.Regulation Specifies That Extremity Dose Limits Apply to Hands & Forearms,Feet & Ankles,Per Info Notice 81-26,Part 3 ML20245K3781989-08-0909 August 1989 Submits Guidelines to Be Used for Submittal & Review of Objectives & Scenario Packages Prior to Emergency Exercise & Provides List of Individuals to Receive Scenario in Lieu of Normal Distribution ML20247E4661989-07-24024 July 1989 Submits Response to Requesting Exemption from Payment of Annual License Fees for Plant.Util Failed to Demonstrate Under 10CFR171.11 an Adequate Basis to Support Exemption Request,Therefore,Request Denied ML20246J0901989-07-0707 July 1989 Denies Util 890522 Request for Exemption from 10CFR50.54(W) Re Required Amount of Onsite Insurance Coverage.Insurance Requirements of 10CFR50.54(W) Appropriate for Plants W/Full Power OLs ML20246E9611989-07-0606 July 1989 Forwards Ack Receipt of Petition Filed by Ecology Ctr of Southern California Under 2.206 ML20245D3081989-06-19019 June 1989 Forwards Request for Addl Info to Continue Review of Response to Generic Ltr 88-01, IGSCC Problems in BWR Austenitic Stainless Steel Piping. Response Should Also Be Submitted to Viking Sys Intl at Listed Address ML20244B8901989-05-25025 May 1989 Forwards Director'S Decision 89-03 & Fr Notice Re Hiatt 10CFR2.206 Petition Expressing Concern Re 880309 Power Oscillation Event at LaSalle Unit 2.Petition Denied. Request to Reopen Proceeding Re ATWS Treated Per 10CFR2.802 IR 05000322/19890041989-05-25025 May 1989 Forwards Insp Rept 50-322/89-04 on 890221-0505.No Violations Noted ML20247C3001989-05-18018 May 1989 Discusses Util 890221 Response to Generic Ltr 88-14, Instrument Air Supply Sys Problems Affecting Safety-Related Equipment. Util Taking Correct & Positive Measures Towards Ensuring That Plant Does Not Experience Subj Problems ML20247A4641989-05-12012 May 1989 Grants 881118 Request for Exemption from Licensing Fees for 890422-0630.Prorated Invoice for Portion of Third Quarter of FY89 Encl ML20246E1591989-05-0404 May 1989 Requests That Util Proceed to Implement Conceptual Design for Core Spray Injection Valve Low Pressure Permissive Logic & Setpoint Before Startup After First Refueling Outage,Per 830218 Commitment ML20246J4531989-05-0404 May 1989 Advises That Financial Info for 1989 Submitted in Util Satisfies 10CFR140.21 Requirement That Licensee Maintain Approved Guarantee of Payment of Deferred Premiums for Each Operating Reactor Over 100 Mwe Owned ML20247A7481989-05-0303 May 1989 Extends Invitation to Power Reactor Operator Licensing Seminar on 890531 in King of Prussia,Pa.Meeting Agenda Encl NUREG-1357, Forwards Tech Specs (NUREG-1357) & Sser 10.W/o Encls1989-05-0303 May 1989 Forwards Tech Specs (NUREG-1357) & Sser 10.W/o Encls ML20245B8851989-04-21021 April 1989 Forwards License NPF-82,nonradiological Environ Protection Plan,Notice of Issuance of Ol,Amend 3 to Indemnity Agreement B-87 & Sser 10.W/o Sser 10 ML20244D2371989-04-11011 April 1989 Forwards Environ Assessment & Finding of No Significant Impact Re 860327 & 850619 Requests for Exemption from 10CFR50.44(c)(3)(i) to Permit Reactor to Operate for 120 EFPD Before Containment Atmosphere Must Be Inerted ML20248G7131989-04-0404 April 1989 Forwards Operational Readiness Assessment Team Insp Rept 50-322/89-80 on 890311-27.Listed Items Require Resolution W/Nrc Prior to Operation Above 5% Power ML20248J5481989-03-31031 March 1989 Forwards Safety Insp Rept 50-322/89-05 on 890314-17.No Violations Noted ML20247L3781989-03-29029 March 1989 Discusses FEMA Review of Rev 10 to Offsite Emergency Plan & FEMA Exercise Assessment.Fema Continues to Support Overall Finding of Reasonable Assurance Transmitted to NRC on 880909 ML20247E2991989-03-28028 March 1989 Ack Receipt & Review of Changes to Jan 1989 Rev 9 to Emergency Preparedness Plan.Changes Consistent W/ Requirements of 10CFR50.54(q) & Acceptable ML20236B9471989-03-13013 March 1989 Forwards Safety Insp Rept 50-322/89-02 on 890109-13.No Violations Noted ML20236B9331989-03-13013 March 1989 Forwards Safeguards Insp Rept 50-322/89-03 on 890213-16.No Violations Noted ML20236E1731989-03-10010 March 1989 Requests Review of Encl camera-ready Tech Specs to Document & Certify Accuracy W/Facility Usar,Per 890301 Meeting ML20235Y9391989-03-0202 March 1989 Forwards Insp Rept 50-322/89-01 on 890104-0220.No Violations Noted.Matter Noted in Rept Detail 4.1 Re Specific Recurrent Failure of Valve to Seat Properly Will Be Evaluated Further by NRC as Measure of Licensee Performance ML20235S2741989-02-17017 February 1989 Forwards Exam Rept 50-322/88-12OL of Exam Administered During Wk of 881212 ML20235M1811989-02-0808 February 1989 Forwards SER Accepting Util 880909 & 1221 Responses to NRC Bulletin 88-005, Nonconforming Matls Supplied by Piping Supplies,Inc at Folsom,Nj & West Jersey Mfg Co at Williamstown,Nj. Issue Considered Resolved ML20196E5641988-11-30030 November 1988 Forwards Amend 10 to License NPF-36 & Safety Evaluation. Amend Changes Definition of Core Alteration in Tech Specs to Include Certain Exceptions & Changes Footnotes in Tech Specs to Be Consistent W/New Definition ML20196B6581988-11-30030 November 1988 Forwards Amend 9 to License NPF-36 & Safety Evaluation.Amend Revises Attachment 3 to Plant License Re Maint & Surveillance for Tdi Emergency Diesel Generators ML20206J4981988-11-23023 November 1988 Forwards Radiological Safety Insp Rept 50-322/88-09 on 881017-21.No Violations Noted 1990-09-27
[Table view] Category:OUTGOING CORRESPONDENCE
MONTHYEARML20212J9991999-10-0101 October 1999 Responds to Recent Ltr to President Clinton,H Clinton, Chairman Jackson &/Or Wd Travers Expressing Concern Re Millstone Npps.Nrc Continues to Monitor Performance of Plant to Ensure That Public Health & Safety Adequately Protected ML20212K1241999-10-0101 October 1999 Responds to Recent Ltrs to Chairman Jackson,Commissioners & Wd Travers,Expressing Concern Re Millstone Npps.Nrc Continues to Monitor Performace of Millstone to Ensure That Public Health & Safety,Adequately Protected ML20212L1971999-10-0101 October 1999 Responds to Recent Ltr to Chairman Jackson & Commissioners Expressing Concerns Re Millstone NPPs & Continued Lack of Emergency Mgt Plan for Eastern Long Island.Nrc Continues to Monitor Plant Performance to Ensure Public Health & Safety ML20212L2171999-10-0101 October 1999 Responds to Recent Ltr to President Wj Clinton,Chairman Jackson & Commissioners,Wd Travers & Ferc,Expressing Concerns Re Millstone NPPs & Continued Lack of Emergency Mgt Plan for Eastern Long Island ML20212L1831999-10-0101 October 1999 Responds to Recent Ltr to Wd Travers Expressing Concerns Re Millstone NPPs & Continued Lack of Emergency Mgt Plan for Eastern Long Island.Nrc Continues to Monitor Performance of Millstone to Ensure Adequate Protection to Public Health ML20212L2081999-10-0101 October 1999 Responds to Recent Ltrs to President Wj Clinton,Chairman Jackson & Commissioners & Wd Travers,Expressing Concerns Re Millstone NPPs & Continued Lack of Mgt Plan for Eastern Long Island.Nrc Continues to Monitor Plant Performance ML20059J8101994-01-26026 January 1994 Responds to 930701 & 16 Ltrs Re Changes to Shoreham Nuclear Power Station Revised Security Plan for Long Term Defueled Condition,Fuel Storage in Spent Fuel Identified as Rev 2. Changes Acceptable ML20058P2831993-12-0808 December 1993 Advises That Rev 2 to Security Plan for Long Term Defueled Condition,Fuel Storage in Spent Fuel Pool Consistent W/ Provisions of 10CFR50.54(p) & Acceptable for Inclusion Into Plan W/Encl Exceptions.Exceptions Withheld Per 10CFR73.21 ML20058D1971993-11-22022 November 1993 Forwards Insp Rept 50-322/93-03 on 930801-1008.No Violations Noted.Weaknesses Were Identified in Initial Fuel Shipment at Shoreham Station ML20058K7301993-11-16016 November 1993 Informs That Case 93-4269,State of Nj Vs Long Island Power Authority Filed on 930921,seeking to Prevent Barge Shipments of Slightly Spent Fuel from Defunct Shoreham Nuclear Power Plant to Limerick Plant Dismissed on 931021 ML20062J7981993-11-0505 November 1993 Forwards EA & Finding of No Significant Impact in Response to 930706 Request for Exemption from Revised Requirements of 10CFR20 for Unit 1.Schedular Exemption Granted ML20059B2231993-10-22022 October 1993 Ack Receipt of 931008 Petition Filed W/Edo,Requesting That Commission Take Immediate Action to Halt Ongoing Shipments of Fuel ML20057F2071993-09-30030 September 1993 Forwards Exemption from Emergency Preparedness Requirements of 10CFR50.54(q),per 930126 Request & SER ML20057B7201993-09-14014 September 1993 Forwards EA & Finding of No Significant Impact in Response to 930126 Request for Exemption from Emergency Preparedness Requirements of 10CFR50.54(q).Informs That After EA & Fonsi Published in Fr,Exemption Can Be Granted ML20057D8981993-09-13013 September 1993 Forwards Enclosure (8) to SECY-93-166 Re Proposed Characteristics of Design Basis Vehicle.W/O Encl ML20056H5131993-08-26026 August 1993 Accepts Changes to Safeguards Contingency Plan Identified as Rev 6.Changes Consistent w/10CFR50.54(p) ML20056H1991993-08-26026 August 1993 Responds to Re Changes to Shoreham Nuclear Power Station Guard Training & Qualification Plan Identified as Rev 6.Rev Consistent W/Provisions of 10CFR50.54(p) & Acceptable for Inclusion Into Plan IR 05000322/19930021993-08-16016 August 1993 Ack Receipt of Informing NRC of Steps Taken to Correct Violations Noted in Insp Rept 50-322/93-02 ML20056C7151993-07-14014 July 1993 Forwards Amend 10 to License NPF-82 & Se.Amend Revises Defueled TS by Deleting Requirement That Radioactive Effluent Release Rept Be Submitted on Semiannual Basis & Eliminates Requirements for Ac Sources ML20056G0041993-06-25025 June 1993 Submits Info Re Implementation of Training Rule 10CFR50.120 for Licensees of Plant in Decommissioning Process ML20058M0361993-04-12012 April 1993 Partial Response to FOIA Request for Documents.Forwards Records in App L Which Are Being Withheld Partially for Listed Reasons,(Ref FOIA Exemptions 5) ML20128G6271993-02-0202 February 1993 Forwards Insp Rept 50-322/92-05 on 921013-1231.No Violations Noted.One Unresolved Item Described.Decommissioning Activities Generally Well Managed ML20128H2951993-01-29029 January 1993 Informs That NRC Has Reviewed & Approved Licensees Ltr LSNRC-2019 Dtd 921230,requesting Change to Shoreham Decommissioning Plan in Accordance W/Condition 4 for Decommissioning Order ML20126G9351992-12-22022 December 1992 Submits Results of Review of 921204 & 14 Requests for Approval of Changes to Decommissioning Plan Covering Decommissioning of Existing Liquid Radwaste Redundant Sys. Removal of Redundant Sys Approved ML20126F9431992-12-16016 December 1992 Provides Interim Response to Re Transnuclear Inc Application for License to Export Irradiated Fuel from Facility in New York to Cogema in France ML20126G9231992-12-16016 December 1992 Forwards Comments Per Review of Rev 0 to Decommissioning Project Termination Survey Plan,Submitted Via . Addl Info Needed to Complete Review of Proposal to Exclude Fe-55 from Consideration W/Surface Contamination Limits ML20128E1061992-12-0202 December 1992 Forwards Insp Rept 50-322/92-04 on 920627-1012 & Notice of Violation ML20133N0981991-08-27027 August 1991 Forwards Viewgraphs Used by Long Island Lighting Power Assoc During Meeting W/Nrc on 910816 ML20058J0591990-11-19019 November 1990 Forwards NRC Public Notice of 901108 License Amend Request Re Shipment of Fuel Support Pieces to Low Level Radwaste Disposal Repository at Barnwell,Sc ML20058H8091990-11-14014 November 1990 Responds to Indicating Desire to Ship 137 Fuel Support Castings & 12 Peripheral Pieces to Low Level Radwaste Repository ML20062F4301990-11-0808 November 1990 Advises That Ofc of General Counsel Designated to Review & Resolve Six Petitions Filed by Scientists & Engineers for Secure Energy & Stated School District Re Amends to Ol. W/Certificate of Svc.Served on 901109 ML20062C1901990-10-24024 October 1990 Advises That Commissioner Jr Curtiss Will Visit Plant on 901113 to Tour Facility & Meet W/Lilco Mgt & Operating Personnel to Review General Status of Activities at Plant. W/Certificate of Svc.Served on 901024 ML20058G4471990-10-18018 October 1990 Forwards Sept 1990 Rept to Commission on Implementation of TMI Action Plan Items,Per 900320 Commitment.W/O Encl.Review Concluded for All But Two Units ML20062B6631990-10-12012 October 1990 Extends Invitation to Attend 910220-21 Util Symposium/ Workshop in King of Prussia,Pa Re Engineering Role in Plant Support ML20059M7901990-09-27027 September 1990 Advises That 880708 Response to NRC Bulletin 88-004 Re Potential safety-related Pump Loss Acceptable ML20059M4991990-09-20020 September 1990 Forwards Insp Rept 50-322/90-02 on 900606-0825.No Violations Noted ML20056B4481990-08-21021 August 1990 Forwards Exemption from fitness-for-duty Requirements Re 10CFR26,per .Exemption Requested to Limit Scope of Program to Persons W/Unescorted Access to Area Containing Equipment Necessary to Support & Maintain Storage of Fuel ML20059A6491990-08-16016 August 1990 Grants Waiver of Compliance from Limiting Condition for Operation 3.7.1.2.b.3 of Tech Spec on Plant Svc Water Sys, Per 900810 & 15 Ltrs.Waiver Allows Performance of Underwater Radiation Survey & Physical Insp of Selected Fuel Elements ML20059A6351990-08-15015 August 1990 Forwards Notice of Consideration of Issuance of Amend to License NPF-82 & Proposed NSHC Determination & Opportunity for Hearing Re 900105 Application ML20059A7151990-08-14014 August 1990 Expresses Appreciation for Remarks on Status & Schedules During drop-in Visit at Region I on 900731.Summary of Discussion Encl ML20058N8391990-08-13013 August 1990 Forwards Environ Assessment & Finding of No Significant Impact Re 900315 Request for Exemption from Full Scope of Fitness for Duty Requirements of 10CFR26 ML20058P1921990-08-0707 August 1990 Forwards Insp Rept 50-322/90-03 on 900710-13.No Violations Noted.One Unresolved Item Noted ML20058M5951990-08-0606 August 1990 Discusses Licensee Engineering Initiatives.Encourages Initiation of Initiative Similar to Region V Licensees Establishment of Engineering Mgrs Forum to Foster Disciplined & Coordinated Approach to Initiatives ML20056A1971990-07-31031 July 1990 Forwards Amend 6 to License NPF-82,safety Evaluation,Notice of Issuance & Exemption Re Defueled Emergency Preparedness License Condition.Proposed Changes Would Allow Util to Cease Offsite Emergency Preparedness Activities ML20055G5691990-07-19019 July 1990 Grants Util 15-day Extension of 900619 Waiver of Compliance Re OL Paragraph 2.C.(13) Quarterly Drills License Condition. Extension Will Allow NRC to Complete Review of Associated Request to Cease Offsite Emergency Preparedness Activities ML20055D2911990-06-27027 June 1990 Forwards Review of Util 900105 Request to Amend Tech Specs to Reflect Plant Protracted Defueled Condition.Meeting Should Be Scheduled at Site on 900719 & 20 to Discuss Finalizing Plant Defueled Tech Specs ML20055E3591990-06-25025 June 1990 Forwards Amend 5 to License NPF-82 & Safety Evaluation.Amend Changes Administrative Section of Tech Specs & Moves Procedural Details Involving Radioactive Effluent Monitoring Instrumentation & Equipment Requirements to ODCM ML20055C8281990-06-19019 June 1990 Grants 900530 Request for Waiver of Compliance from License NPF-82,Paragraph 2.C.(13) Re Quarterly Drills License Condition,Pending NRC Action on 891215 Request to Cease Offsite Emergency Preparedness Activities 1999-10-01
[Table view] |
Text
. -
q
/yun na 'o, UNITED STATES
! 'y. , y } NUCLEAR REGULATORY COMMISSION 3 g "), 5 I REGION I 8,
% . . . . . ,'f KING oF PRUSSIA, PENNSYLVANIA 1e406 Docket No. 50-322 APR 121983 EA 83-20 Long Island Lighting Company ATTN: Mr. M. S. Pollock Vice President Nuclear 175 East Old Country Road Hicksville, New York 11801 Gentlemen:
Subject:
Inspection No. 50-322/82-35 This refers to the NRC inspection conducted between November 30 and December 31, 1982 at the Long Island Lighting Company's (LILCO) Shoreham Nuclear Station, Shoreham, New York, of activities authorized by NRC Con-struction Permit No. CPPR-95. The report of this inspection was forwarded to -
you on February 24, 1983. You have provided us a written reply to this report SNRC-859 dated March 16, 1983. During the 1.1spection, a violation of NRC requirements was identified involving inadequate review and approval of the results of a preoperational test of a diesel generator. This violation was discussed during a management meeting held with you and other members of your staff on January 25, 1983, at an enforcement conference held on March 24, 1983, and during a subsequent phone conversation' cn March 25, 1983 between Messrs. J. Allan and E. Greenman of Region I and yourself.
This violation, which is desgribed in the attached Notice of Violation and Proposed Imposition of Civil Penalty (Notice), involved the performance of a preoperational test of a diesel generator in which the test results indicated that one of the test requirements was not satisfied. Furthermore LILCO personnel approved the recults despite the fact that the test criterion was not satisfied.
l The Test Engineer, Lead Startup Engineer, Startup Manager, and Joint Test l Group all approved the test results during the preoperational testing review process. Additionally, an Operational Quality Assurance (0QA) inspector witnessed the test and signed the test documentation. A second OQA inspector signed the test documentation accepting the results. The approval'of the results of a test performed to confirm a safety system's capability of meeting design safety requirements, when, in fact, test .results presented to the Joint -
Test Group (JTG) have not satisfied all requirements, is of significant concern to the NRC.
We recognize that high speed chart recorder data traces were taken during por-tions of the two-nour load test run. However, these recorder traces were not specifically addressed in the test acceptance criterion and were not reviewed by the JTG. Additionally, our review indicates that these traces show that portions of the test were run at generator load values less than the minimum specified by procedure.
CERTIFIED MAIL RETURN RECEIPT REQUESTED
( 9305040785 830425 PDR ADDCK, 05000322 G PDR
Long Island Lighting Company 2 We also recognize that at the time of our inspection, additional audit / reviews of the completed test results by Cperational Quality Assurance (0QA) and the -
Review of Operations Committee (ROC) had not been performed. It is not clear to us, however, that these additional audit / reviews would hav'e identified 'the' problems. For example, the Chairman of the JTG, which approved the test data, also serves as Chairman of the ROC, and OQA personnel had previously reviewed and signed the test procedure.
During meetings held on January 25, March 24, 1983 and during a phone conver-sation on March 25, 1983, we discussed our concerns with you regarding this violation. We have reviewed your written response and corrective actions',
documented in letter SNRC-859 which discusses, in part, the issues noted above. Based on the evaluations conducted by you to date, you conclude that the circumstances discussed in inspection report 82-35 are an isolated instance.
We also note your commitment to the NRC Senior Resident Inspector to reperform electrical preoperational testing.of Diesel Generator 102 prior to. fuel load.
Additionally, as a. result of NRC inquiries into diesel generator problems
- noted during inspection 83-07, LILCO has conducted additional evaluations and, in response to NRC concerns, is developing a reliability program for the diesel. generators. These actions are subject to review by Region I.
While we have considered the above remedial actions, the diesel generator testing violation demonstrates a . lack of aggressiveness on the part of LILCO to pursue, identify and resolve associatWd problems that can affect the reli-ability of the diesel generators, including attention to detail during per-formance, data review, and approval of the test results sof your preoperational test program. These actions are necessary to demonstrata lhat the compcnents will perform satisfactortly in service. , " '
In order to emphasize the need for more attention to' detail during review and, approval of test results, I have been authorized, after consultation with the l Director of the Office of Inspection and Enforcement, to issue the attached i
Notice of Violation and Proposed Imposition of Civil Penaity in the amountio f Forty Thousand Dollars ($40,000) for the violation descrited'in The attached Notice. This violation has been classified at Severity Level 'III in accordance with Section C.2 of Supplement II of the NRC Enforcement Policy (10 CFR part 2, Appendix C), published in the Feceral Register,147 FR 9987 (March 9,1932).
You are required to rescond to'the attached Notice'an,d should follow the in-structions specified therein when preparing your-r3spcase. In your, response, you should indicate the specific actions that you have taken, or will take, to assure that preoperational test results are adequately reviewed, and that approval of results is given only after adequate review. Your reply to this i letter and the results of ' future inspections will be considered in determining I whether further enforcement is appropriate. v fn accordance with 10 CFR.2.790 of the NRC's " Rules of Practice," Part 2, Title 10, Code of Federal Regulations, a copy of this letter and its enclosure l will be placed in the NRC Oublic Document Room.
k
__. , . _ _ , _ . , . - - - - - - - . . - - .1 --- - - - -- , - - - - - - ~ - - - - - ~ ~ - - - ' ' - ' ' - * ' " - " ~ - - - ' - * - - ~ - ~ * " ' " " - "
,~- .
s Long Island Lighting Company 3 The responses directdd by this letter and the attached Notice are not subject to the clearance procedures of the Office of Management and Budget, otherwise required by the Paperwork Reduction Act of'1980, PL 96-511.
Sincerely,
\l s ,
n b J 81
,' es M. Allan 1 Acting Regional Administrator
Enclosure:
Notice of Violation and Proposed Imposition of Civil Penalty cc w/encis: '.
J. Rivello, Plant Manager J. L. Smith, Manager of Special Projects Edward ~M. Barrett, Esq.
Jeffrey L. Futter, Esq.
I. F. Gerecke, Manager, QA Department L. Brenner, ASLB J. Carpenter, ASLB I- ,
P. Morris, ASLB Public Document Room (PDR)
Local Public Document Room (LPDR)
Nuclear Safety Information Center (NSIC)
NRC Resident Inspector State of New York Director, Power Division, PSC Shoreham Hearing Service List ,
i l
i
\
_ . . _ _ _ -