APPENDIX A NOTICE OF VIOLATION Portland General Electric Company Docket No. 50-344 121 S. W. Salmon Street License No. NPF-1 Portland, Oregon 97204 As a result of inspections conducted March 17-21, 1986, and in accordance with the NRC Enforcement Policy, 10 CFR 2, Appendix C, the following violation was identified.

Technical Specification 3.3.3.11, " Radioactive Gaseous Process and Effluent Monitoring Instrumentation," requires in section b. that:

"With the inoperable instrument channels identified in Table 3.3-13 items 1, 2, 3c, 4 and 5 not returned to OPERABLE status within 30 days, identify the cause of the inoperable channels in the Semiannual Radiological Environmental Report in lieu of any other report."

Contrary to the above, the licensee failed to report the status and identify the cause of an inoperable radioactive gaseous effluent monitoring channel (FR-3100) in the Semiannual Radiological Enviroamental Report for the period of July 1, 1985 through December 31, 1985, dated February 28, 1986.

Specifically, the moisture removal system for PRM-6 became operational during July 1985 and Channel FR-3100 was not made operable as of March 17, 1986.

This is a Severity Level V Violation (Supplement I) in view of the immediate corrective actions taken during the inspection which j

were verified by the inspector prior to leaving the site, no response to this Notice is required.

APR 111986

[g

/

Dated F. A. Wenslawski, Chief Emergency Preparedness and Radiological Protection Branch 8604250224 860411 PDR ADOCK 05000344 G

PDR

.