A 5b-3M

,f B ALTIMORE '

GAS AND ELECTRIC CHARLES CENTER. P.O. BOX 1475 BALTIMORE, MARYLAND 21203 ELECTnsc ENGINEERING July 30, 1980 g,,,,,,,

Mr. Boyce H. Grier, Director Office of Inspection and Enforcement Region 1, USNRC 631 Park Avenue King of Prussia, PA 19h06

Dear Mr. Grier:

Subject:

Calvert Cliffs Nuclear Power Plant Units Nos.1 and 2 License Nos.

DPR-53 and 69 Nonroutine Radiological Environmental Operating Report This report is submitted in duplicate to comply with the require-ments of Appendix B Environmental Technical Specifications Section 5.6.2.b.

The Oyster sarples were collected on June 2h, 1980 from the Camp Conoy sampling location and analyzed for gamma-emitting radionuclides as l

required. The results of the analyses showed the presence of Ag-110m at 78t7 pCi/Kg(vet).

The oyster samples collected on the same date from the Kenwood Beach sampling location (the background location) showed Ag-110m at

$ 5 pCi/Kg(vet).

Based on the observed levels of Ag-110m during this sampling period, for an average adult consuming one kilogram of oysters per year the doses to lessthan7x10gWholeBodyareestimatedatlessthan5x10-3 mrem /yearand the GI Tract an mrem / year, respectively. These are very small fractions of the allovable 25 mrem / year (GI Tract) and 25 mrem / year (Whole Body) doces to members of the general public, (k0 CFR Part 190 Environmental Radiation Protection Standards for Nuclear Power Operations) and are therefore considered to be of no consequence to the health and safety of the public.

Very truly yours, 4/

-s J. W. Stout, Jr.

Chief Environmental Engineer cc:

Director Office of Nuclear Reactor Regulation Washington, D. C.