CALVERT CLIFFS NUCLEAR POWER PLANT CORE OPERATING LIMITS REPORT for UNIT 2, CYCLE 13 REVISION 0 l
i 1 A. /d)
'Of199 RbSPONSIBLE ENGINEER / DATE UMd.b 4/91 INDEPEdd)ENT REVIEWER / DATE 1 4 pall D 7 PRINCIPAL ENGINEER-NEU / DATE A
30 Calvert Cliffs 2, Cycle 13 COLR Page 1 of 23 Rev.O
r-l I
I l
CORE OPERATING LIMITS REPORT CALVERT CLIFFS UNIT 2, CYCLE 13 l
)
l The following limits are included in this Core Operating Limits Report:
4 Soecification Title East Introduction.....
De fi n i t i o n s.....................................................
.. 5 3.1.1 Shutdown Margin (SDM)........................
...........6 3.1.3 Moderator Temperature Coefficient (MTC)...
........6 3.1.4 Control Element Assembly (CEA) Alignment......
.. 6 3.1.6 Regulating Control Element Assembly (CEA) Insertion Limits......
... 6 3.2.1 Linear Heat Rate (LHR)..................................
.... 6 T
3.2.2 Total Planar Radial Peaking Factor (Fxy )......
..... 7 T
3.2.3 Total Integrated Radial Peaking Factor (Fr ).......
.... 7 3.2.5 Axial Shape index (ASI)..........
.7 3.3.1 Reactor Protective System (RPS) Instrumentation - Operating....
.... 7 3.9.1 Boron Concentration..................................
... 7 List of Approved Methodologies.......................
.. 20 The following figures are included in this Core Operating Limits Report:
Number Illic Eage Figure 3.1.1 Shutdown Margin vs. Time in Cycle.......
.. 8 Figure 3.1.4 Allowable Time To Realign CEA Versus 7
Initial Total Integrated Radial Peaking Factor (F, )......
..........9 Figure 3.1.6 CEA Group Insertion Limits vs. Fraction of Rated Thermal Power.........
.10 Figure 3.2.1-1 Allowable Peak Linear Heat Rate vs. Time in Cycle..
.1 I Figure 3.2.1-2 Linear Heat Rate Axial Flux Offset Control Limits..
.12 T
Figure 3.2.1-3 Total Planar Radial Peaking Factor (Fxy ) vs.
i Maximum Allowable Fraction of Rated Thermal Power.
...........13 T
Figure 3.2.2 Total Planar Radial Peaking Factor (F,y ) vs. Allowable Fraction of Rated Tbermal Power...................
... 14 T
Figure 3.2.3 Total Integrated Radial Peaking Factor (F, ) vs.
Allowable Fraction of Rated Thermal Power...........
.15 Figure 3.2.5 DNB Axial Flux Offset Control Limits...............
..............16 Figure 3.3.1-1 Axial Power Distribution - High Trip Setpoint Peripheral Axial Shape Index vs. Fraction of Rated Thermal Power......
.. 17 l
Figure 3.3.1-2 Thermal Margin / Low Pressure Trip Setpoint - Part 1.....
. 18 Figure 3.3.1-3 Thermal Margin / Low Pressure Trip Setpoint - Part 2.
. 19 -
Calvert Cliffs 2, Cycle 13 COLR Page 2 of 23 Rev.O
[
l l
I UNIT 2 CORE OPERATING LIMITS REPORT LIST OF EFFECTIVE PAGES Page No.
Rev. No.
1 0
2 0
3 0
4 0
5 0
6 0
7 0
8 0
9 0
10 0
11 0
12 0
13 0
14 0
15 0
16 0
17 0
18 0
19 0
20 0
21 0
22 0
23 0
l t
f
~
?
Calvert Cliffs 2, Cycle 13 COLR Page 3 of 23 Rev.O
r 1
l j
L l
INTRODUCTION l'
This report provides the cycle-specific limits for operation of Calvert Cliffs Unit 2, Cycle 13. It contains the limits for:
Moderator Temperature Coefficient (MTC) i Control Element Assembly (CEA) Alignment Regulating Control Element Assembly (CEA) Insertion Limits Linear Heat Rate (LHR)
Total Planar Radial Peaking Factor (F '(7) 7) x Total Integrated Radial Peaking Factor F, l
Axial Shape Index (ASI)
Reactor Protective System (RPS) Instrumentation - Operating Boron Concentration In addition, this report contains a number of figures which give limits on the parameters listed above. If any of the limits contained in this report are exceeded, corrective action will be taken as defined in the Technical Specifications.
i This report has been prepared in accordance with the requirements of Technical Specifications.
The cycle specific limits have been developed using the NRC-approved methodologies given in j
the " List of Approved Methodologies" section of this report anc. m the Technical Specifications.
COLR Revision 0 1
Initial Release of Unit 2 Cycle 13 COLR (Safety Evaluation SE00345).
i 1
l Calvert Cliffs 2, Cycle 13 COLR Page 4 of 23 Rev.0 1
l.
r l
DEFINITIONS
' Axial Shape Index (ASI) i ASI shall be the power generated in the lower half of the core less the power generated in the upper half of the core, divided by the sum of the power generated in the lower and upper halves of the core.
ASI = 3 Wer-upper, y lower + upper The Axial Shape Index (Y ) used for the trip and pretrip signals in the Reactor Protection i
System (RPS) is the above value (Yc) modified by an appropriate multiplier (A) and a constant (B) to determine the true core axial power distribution for that channel.
Y = AYs + B i
Total Integrated Radial Peaking Factor-F[
The Total Integrated Radial Peaking Factor is the ratio of the peak pin pnwer to the average pin power in an unrodded core, Total Planar Radial Peaking Factor - F,y' The Total Planar Radial Peaking Factor is the maximum ratio of the peak to average power density of the individual fuel rods in any of the unrodded horizontal planes.
l
. Calvert Cliffs 2, Cycle 13 COLR Page 5 of 23 Rev.O
.=
j.
l I
CYCLE SPECIFIC LIMITS FOR UNIT 2, CYCLE 13 l
3.1.1 Shutdown Margin (SDM)(SR 3.1.1.1)
Tavg > 200 *F-Afodes 3 and 4:
The shutdown margin shall be equal to or greater than the limit line of COLR Figure 3.1.1.
Tavg S 200 F-Afode 5:
The shutdown margin shall be 2 3.0% Ap.
3.1.3 Moderator Temperature Coefficient (MTC) (SR 3.1.3.2)
The Moderator Temperature Coefficient (MTC) shall be less negative than -3.0 x 10-4 Ap/ F at rated thermal power.
'3.1.4 Control Element Assembly (CEA) Alignment (Action 3.1.4.B.1)
The allowable time to realign a CEA may be provided by the full core power distribution monitoring system (Better Axial Shape Selection System - BASSS) or COLR Figure 3.1.4,
" Allowable Time to Realign CEA Versus Initial Total Integrated Radial Peaking Factor (F,T)." If COLR Figure 3.1.4 is used, the pre-misaligned F, value used to determine the allowable time to realign the CEA shall be the latest measurement taken within 5 days prior to the CEA misalignment, if no measurements have been taken within 5 days prior to the misalignment and the full core power distribution monitoring system is unavailable then the time to realign is zero(0) minutes.
3.1.6 Regulating Control Element Assembly (CEA) Insertion Limits (SR 3.1.6.1 and SR 3.1.6.2)
The regulating CEA groups insertion limits are shown on COLR Figure 3.1.6.
3.2.1 Linear Heat Rate (LHR)(SR 3.2.1.2 and SR 3.2.1.4)
The linear heat rate shall not exceed the limits shown on COLR Figure 3.2.1-1.
The axial shape index power dependent control limits are given in COLR Figure 3.2.1-2.
When using the excore detector monitorine system (SR 3.2.1.2):
The alarm setpoints are equal to the ASI limits, therefore when the alarms are adjusted, they provide indication to the operator when ASI is not with the limits.
The maximum allowable fraction of rated thermal power vs. F,[ is shown in COLR Figure 3.2.1-3.
The axial shape index alarm setpoints are shown on COLR Figure 3.2.1-2.
When using the incore detector monitoring system (SR 3.2.1.4):
The alarm setpoints are adjusted to protect the Linear Heat Rate limits shown on COLR Figure 3.2.1-1 and uncertainty factors are appropriately included in the setting of these alarms.
~
Calvert Cliffs 2, Cycle 13 COLR Page 6 of 23 Rev.O
?
CYCLE SPECIFIC LIMITS FOR UNIT 2, CYCLE 13 The uncertainty factors for the incore detector monitoring system are:
1.
A measurement-calculational uncertainty factor of 1.062, 2.
An engineering uncertainty factor of 1.03, 3.
A linear heat rate uncertainty factor of 1.002 due to axial fuel densification and thermal expansion, and 4.a For measured thermal power less than or equal to 50 percent but greater than 20 percent of rated full core power a thermal power measurement uncertainty factor of 1.035.
4.b For measured thermal power greater than 50 percent of rated full core power a thermal power measurement uncertainty factor of 1.020.
3.2.2 Total Planar Radial Peaking Factor (F ')(SR 3.2.1.1 and SR 3.2.2.1) xy T
The calculated value of Fxy shall be limited to s 1.65.
T The allowable combination of thermal power and Fxy are shown on COLR Figure 3.2.2.
3.2.3 Total Integrated Radial Pealdng Factor (F,T) (SR 3.2.3.1)
The calculated value of F,7 shall be limited to s 1.65.
The allowable combinations of thermal power and F,' are shown on COLR Figure 3.2.3.
3.2.5 Axial Shape Index (ASI) (SR 3.2.5.1)
The axial shape index and thermal power shall be maintained within the limits established by the Better Axial Shape Selection System (BASSS) for CEA insenions of the lead bank of <
55% when BASSS is operable, or within the limits of COLR Figure 3.2.5 for CEA insertions specified by COLR Figure 3.1.6.
3.3.1 Reactor Protective System (RPS) Instrumentation - Operating (Reactor Trip Setpoints) (TS Table 3.3.1-1)
The Axial Power Distribution - High trip setpoint and allowable values are given in COLR Figure 3.3.1-1.
The Thermal Margin / Low Pressure (TMILP) trip setpoint is given in COLR Figures 3.3.1-2 and 3.3.1-3. The allowable values are to be not less than the larger of(l) 1875 psia or (2) the value calculated from COLR Figures 3.3.1-2 and 3.3.1-3.
3.9.1 Boron Concentration (SR 3.9.1.1)
The refueling boron concentration shall be maintained uniform and sufficient to ensure that the boron concentration is 2 2323 ppm. This refueling boron concentration credits 48 control element assemblies and the boron concentration at 19.8 a/o B' t
l Calvert Cliffs 2, Cycle 13 COLR Page 7 of 23 Rev.0 1
1 6
ACCEPTABLE 5--
OPERATION o
REGION (EOC,4.5) k
%4 da b
(BOC,3.5)
E
@3-MINUMUM SHUTDOWN MARGIN 1
ig2 "
UNACCEPTABLE y
OPERATION g
REGION 1--
TIME IN CYCLE Figure 3.1.1 Shutdown Margin vs. Time in Cycle
~
1 Calvert Cliffs 2, Cycle 13 COLR Page 8 of 23 Rev.O
70 60 e (1.53,60) 50 --
g l
40 --
~
T b
[ 978 -600 Fr Z
30 --
a 6
20 --
a 10 "
ALLOWED REGION O--
(1.63, 0) 1.50 1,55 1.60 1.65 1.70 MEASURED PRE MISALIGNED TOTAL INTEGRATED RADIAL PEAKING FACTOR Figure 3.1.4 Allowable Time to Realign CEA Versus initial Total Integrated Radial Peaking Factor (F/)
Calvert Cliffs 2, Cycle 13 COLR Page 9 of 23 Rev.0 1
!' ' r
0U' 0*"# 8 0 **
I 1.000 e I
I l
l i
e 1
I t
([#0'U""P50 0.000-x y*
t h
.800 l
0 k
j, (0.75, G[oup 5@50%)
'IU'7("*"P80OU"I 0.700 i
i (0.55, Group 5 @ 85%)
la 8
s g
W
(
l
{
( 56, Group 4 @ 50%)
$ 0.500 -
!: Long Tb Steady 5
l l
ls State Insertion Umit, i
l i
mup @ 5%
l 1
0.400 -
i i
j i
i 1
i O
' e i 8
I i
/a-l 0.300 i
f8 f
O e
e i
f O.200
'\\
' (0.20, Gmup s @ s0N '
i Shod Te Steady l
State insenion umn, 0.100 -
a Group 4 @ 20%
4 -l (Group 5 @ $5%)
u (0.00. Gmup 3 @ 60W 0.000 Allowable BASSS Operating Region 5
3 1
1 I
I I
I I
I I
I I
I I
I I
I I
I I
O 20 40 60 80 100 0
20 40 60 80 100 0
20 40 60 80 100 136.0 108.8 81.6 64.4 27.2 0.0 136.0 108.8 81.6 54.4 27.2 0.0 136.0 108.8 81.6 54.4 27.2 0.0 4
2 I
I I
I I
I LI I
I I
I 0
20 40 60 80 100 0
20 40 60 80 100 136.0 108.8 81.6 54.4 27.2 0.0 136.0 108.8 81.6 54.4 27.2 0.0
%CEA INSERTION INCHES CEA WITHDRAWN (Note that 0% insertion is defined in NEOP-23 as ARO)
Figure 3.1.6 CEA Group insertion Limits vs. Fraction of Rated Thermal Power Calve
.'ffs 2, Cycle 13 COLR Page 10 of 23 Rev.O
I l
{
{
1 1
1 l
l 17.0 t
i t
16.5 5
l l
N 216.0 IS l'
i l
-g 6 w15.5 zo i
"h b +15.0 Eo I
i y$
UNACCEPTABLE OPERATION g y14.5 l
'J 3 *14.3 C
- )
i ACCEPTABLE OPERATION m 214.0
<~
it o
l
-j 13.5 i
i 13.0 BOC EOC TIME IN CYCLE Figure 3.2.1-1 Allowable Peak Linear Heat Rate vs. Time in Cycle Calvert Cliffs 2, Cycle 13 COLR Page 11 of 23 Rev.0
t 1.100 1.050 --
1.000 --
(-0.06,1.00)
(0.12,1.00) 0.950 --
UNACCEPTABLE UNACCEPTABLE O'900 --
OPERATION OPERATION REGION REGION 0.850 --
n:
l 0.800 --
O
] 0.750 --
g 0.700 --
(-0.3, 0.70)
K (0.3,0.70)
W l
g 0.650 --
ACCEPTABLE 3 0,600 OPE WlON g
REGION 3 0.550 --
o d 0.500 --
(-0.3, 0.50) o 0.450 --
2 y 0.400 --
O g 0.350 --
u 0.300 --
0.250 --
0.200 --
0.150 --
(-0.45, 0.15) 0.100 --
0.050 e
-0.60
-0.40
-0.20 0.00 0.20 0.40 0.60 PERIPHERAL AXIAL SHAPE INDEX, Yi Figure 3.2.1-2 l
l Linear Heat Rate Axial Flux Offset Control Limits Calvert Cliffs 2, Cycle 13 COLR Page 12 of 23 Rev.O
I E
1.00 e a.
.J!w h
0.90 --
0 5
0.80 -
zOP 1
o ACCEPTABLE VALUE 0.70 --
m E$
B B
l Q 0.60 --
EoER<E 0.50 a
1.40 1.45 1.50 1.55 1.60 1.65 1.70 1.75 1.80 T
Fxy Figure 3.2.1-3 l
l T
Total Planar Radial Peaking Factor (F,y ) vs.
Maximum Allowable Fraction of Rated Thermal Power j
j
. Calvert Cliffs 2, Cycle 13 COLR Page 13 of 23 Rev.O I
I e
l i
l I
i i
1 I
l (1.65,1.00)
UNACCEPTABLE 12: 1.00 e OPERATION I
REGION O
n.
.J(
g OSO "
F,/ LIMITCURVE w
h 8
H (1.7325,0.80) g 0.80 "
ACCEPTABLE g
OPERATION z
REGION 0
P i
0 0.70 --
5 u.
3m<
!E 0.60 --
9 4
0.50 l
l c
1.60 1.65 1.70 1.75 1.80 T
Fxy Figure 3.2.2 Total Planar Radial Peaking Factor (F ') vs.
y l
Allowable Fraction of Rated Thermal Power
~
Calvert Cliffs 2, Cycle 13 COLR Page 14 of 23 Rev.O
F
.o l
I
=
s (1.65,1.00)
UNACCEPTABLE 1.00 c:
OPERATION g
g REGION 2
a j 0.90 --
F,'
LIMIT CURVE 5
5 O
- 0.80 --
(1.7325,0.80) 55 5
ACCEPTABLE F
OPERATION O 0.70 --
REGION E
5 E
Bg 0.60 --
4 0.50 1.60 1.65 1.70 1.75 1.80 T
F, Figure 3.2.3 Total Integrated Radial Peaking Factor (F,') vs.
l Allowable Fraction of Rated Thermal Power 1
I i
(
Calvert Cliffs 2, Cycle 13 COLR Page 15 of 23 Rev.O
I' l.
en l
l
~
1.100 1.050 --
1.000 --
(-0.03,1.00)
(0.15,1.00) 0.950 -- UNACCEPTABLE UNACCEPTABLE 0.900 OPERATION OPERATION REGION REGION
{
0.850 --
y 0.800 --
(0.3,0.80)
$ 0.750 --
2 0.700 --
(-0.3, 0.70) m J
ACCEPTABLE
$ 0.650 --
OPERATION 5
REGION 3 0.600 --
a 0.550 --
y 0.500 -.
(-0.3, 0.50) f 53 0.450 --
u.
O 0.400 --
O P 0.350 --
o f 0.300 --
0.250 --
i 0.200 -
0.150 --
(-0.45, 0.15) 0.100 --
0.050 e :
u
-0.60
-0.40
-0.20 0.00 0.20 0.40 0.60 PERIPHERAL AXIAL SHAPE INDEX, Ye Figure 3.2.5 DNB Axial Flux Offset Control Limits 1
Calvert Cliffs 2, Cycle 13 COLR Page 16 of 23 Rev.0 l
i 1.300 4
1.250 1.200 UNACCEPTABLE UNACCEPTABLE 1.150 OPERATION OPERATION REGION REGION 1.100 1.050 1.000
(-0.2,1.00)
(0.2,1.00)
E 0 h
.950 o 0.000 n.
0.850 h
g 0.800 b
0.750 C
- 0.700 5
0.650 u.o 2 0.600 ACCEPTABLE p
0.550 OPERATION REGION
@ 0.500 0.450 0.400
(-0.6, 0.40)
(0.6, 0.40) 0.350 0.300 i
0.250 0.200 0.150 e
-0.80
-0.60
-0.40
-0.20 0.00 0.20 0.40 0.60 0.80 PERIPHERAL AXIAL SHAPE INDEX, Yi Figure 3.3.1-1 Axial Power Distribution - High Trip Setpoint Paripheral Axial Shape index vs. Fraction of Rated Thermal Power Calvert Cliffs 2, Cycle 13 COLR Page 17 of 23 Rev.O
i i
1 l
l 1.60 i
P #f= 2869.5 x (A1) x (QR1) + 17.98 x Tin - 10820 1.50 O g A1 x QR1 g
1.40 I
i 1.30 <
(-0.6, 1.3) l E
1.20 I
A1 $ +0.1667 x ASI + 1.0 l
1 10 A1 = d0.5 x ASi + 1.0 i
I 1.00 (0.0,1'.0) l i
0.90
-0.60 -0.50 -0.40 -0.30 -0.20 -0.10 0.00 0.10 0.20 0.30 0.40 0.50 0.60 ASI Figure 3.3.1-2 Thermal Margin / Low Pressure Trip Setpoint - Part 1 (ASI vs. A )
1
~
l Calvert Cliffs 2, Cycle 13 COLR Page 18 of 23 Rev.0
4 1.2
, (1.2,1.2) 1,1 l
l 444%)-
1.0 0.9 l
0.8 (0.6, 0.85) i 0.7 f
l g 0.6 g
0.5 l
0.4 /,
i 0.3 ( -(04;4.4)
P[r = 2869.5 x (A1) x (OR1) + 17.98 x Tin - 10820 y
0.2 Oggg A1 x QR1 0.1 0.0 l
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 FRACTION OF RATED THERMAL POWER Figure 3.3.1-3 Thermal Margin / Low Pressure Trip Setpoint - Part 2 (Fraction of Rated Thermal Power vs. QR )
1
~
~ Calvert Cliffs 2, Cycle 13 COLR Page 19 of 23 Rev.O L
r l
LIST OF APPROVED METHODOLOGIES I
(1)
CENPD-199-P, Rev l-P-A,"C-E Setpoint Methodology: C-E Local Power Density and DNB i
LSSS and LCO Setpoint Methodology for Analog Protection Systems," January 1986 (Methodology for Specifications 3.3.1,3.1.6,3.2.1,3.2.2,3.2.3,3.2.5)
(2)
CEN-124(B)-P," Statistical Combination of Uncertainties Methodology Part 1: C-E Calculated Local Power Density and Thermal Margin / Low Pressure LSSS for Calvert Cliffs Units I and !!,"
December 1979 (Methodology for Speci0 cations 3.3.1,3.1.6,3.2.2,3.2.3)
(3)
CEN-124(B)-P, " Statistical Combination of Uncertainties Methodology Part 2: Combination of System Parameter Uncenainties in Thermal Margin Analyses for Calvert Cliffs Units 1 and 2,"
January 1980 (Methodology for Specifications 3.3.1,3.1.6,3.2.3,3.2.5)
(4)
CEN-124(B)-P, " Statistical Combination of Uncertainties Methodology Pan 3: C-E Calculated Departure from Nucleate Boiling and Linear lieat Rate Limiting Conditions for Operation for Calvert Cliffs Units I and 2," March 1980 (Methodology for Speci6 cations 3.1.6,3.2.1,3.2.2, 3.2.3, 3.2.5)
(5)
CEN-191(B)-P,"CETOP-D Code Structure and Modeling Methods for Calvert Cliffs Units 1 and 2 " December 1981 (Methodology for Specifications 3.3.1,3.1.6,3.2.3,3.2.5)
(6)
Letter from Mr. D. H. Jaffe (NRC) to Mr. A. E. Lundvall, Jr. (BG&E), dated June 24,1982, Unit 1 Cycle 6 License Approval (Amendment No. 71 to DPR-53 and SER)[ Approval to CEN-124(B)-P (three parts) and CEN-191(B)-P)]
(7)
CEN-348(B)-P, " Extended Statistical Combination of Uncertainties," January 1987 (Methodology for Specifications 3.3.1,3.1.6,3.2.3,3.2.5)
(8)
Letter from Mr. S. A. McNeil, Jr. (NRC) to Mr. J. A. Tiernan (BG&E), dated October 21,1987, Docket Nos. 50-317 and 50-318, " Safety Evaluation of Topical Report CEN-348(B)-P, Extended Statistical Combination of Uncertainties" (9)
CENPD-161-P-A, " TORC Code, A Computer Code for Determining the Thermal Margin of a Reactor Core," April 1986 (Methodology for Specincations 3.3.1,3.1.6,3.2.3,3.2.5)
(10)
CENPD-162-P-A," Critical Heat Flux Correlation of C-E Fuel Assemblies with Standard Spacer Grids Pan 1, Uniform Axial Power Distribution," April 1975 (Methodology for Specifications 3.3.1, 3.1.6, 3.2.3, 3.2.5)
(11)
CENPD-207-P-A," Critical Heat Flux Correlation for C-E Fuel Assemblies with Standard Spacer Grids Part 2, Non-Uniform Axial Power Distribution," December 1984 (Methodology for Specifications 3.3.1, 3.1.6, 3.2.3, 3.2.5) l (12)
CENPD-206-P-A, " TORC Code, Verification and Simplified Modeling Methods," June 1981 (Methodology for Specifications 3.3.1,3.1.6,3.2.3,3.2.5)
(13)
CENPD-225-P-A, " Fuel and Poison Rod Bowing," June 1983 (Methodology for Specification,s 3.3.1, 3.1.6, 3.2.3, 3.2.5) l l
Calvert Cliffs 2, Cycle 13 COLR Page 20 of 23 Rev.O
r-4
+
(14)
CENPD-266-P-A, "The ROCS and DIT Computer Code for Nuclear Design," April 1983 (Methodology for Specifications 3.3.1,3.1.6,3.2.1,3.2.2,3.2.3,3.2.5)
-(15)
CENPD-275-P-A, "C-E Methodology for Core Designs Containing Gadolinia - Urania Burnable Absorbers," May 1988 (Methodology for Specifications 3.3.1,3.1.6,3.2.1,3.2.2,3.2.3,3.2.5)
(16)
CENPD-382-P-A, " Methodology for Core Designs Containing Erbium Burnable Absorbers," August 1993 (Methodology for Specifications 3.3.1,3.1.6,3.2.1,3.2.2,3.2.3, 3.2.5)~
(17)
CENPD-139-P-A, "C-E Fuel Evaluation Model Topical Report," July 1974 (Methodology for Specifications 3.3.1,3.1.6,3.2.1,3.2.2)
(18)
CEN-161-(B)-P-A, " Improvements to Fuel Evaluation Model," August 1989
_ (Methodology for Specifications 3.3.1,3.1.6,3.2.1,3.2.2)
(19)- CEN-161-(B)-P, Supplement 1-P, " Improvements to Fuel Evaluation Model," April 1986 (Methodology for Specifications 3.3.1,3.1.6,3.2.1,3.2.2)
'(20)
Letter from Mr. S. A. McNeil, Jr. (NRC) to Mr. J. A. Tiernan (BG&E), dated February 4, 1987, Docket Nos. 50-317 and 50-318, " Safety Evaluation of Topical Report CEN-161-
. (B)-P, Supplement 1-P, Improvements to Fuel Evaluation Model" (Approval of CEN-161(B), Supplement 1-P)
(21)
CEN-372-P-A, " Fuel Rod Maximum Allowable Gas Pressure," May 1990 (Methodology for Specifications 3.3.1,3.1.6,3.2.1,3.2.2)
(22) ~ Letter from Mr. A. E. Scherer (CE) to Mr. J. R. Miller '(NRC) dated December 15,1981, LD-81-095, Enclosure 1-P, "C-E ECCS Evaluation Model Flow Blockage Analysis" (Methodology for Specifications 3.2.1,3.2.2)
(23)
CENPD-132, Supplement 3-P-A, " Calculative Methods for the C-E Large Break LOCA Evaluation Model for the Analysis of C-E and E Designed NSSS," June 1985 (Methodology for Specifications 3.2.1,3.2.2 and approval of Letter LD-81-095, dated l
December 15,1981)
(24). CENPD-133, Sup )lement 5, "CEFLASH-4A, a FORTRAN 77 Digital Computer Program for Reactor Blowc.own Analysis," June 1985 (Methodology for Specifications 3.2.1, 3.2.2) l.
(25)
CENPD-134, Supplement 2, "COMPERC-II, a Program for Emergency Refill-Reflood of the Core," June 1985 (Methodology for Specifications 3.2.1,3.2.2)
(26) ' Letter from Mr. D. M. Crutchfield (NRC) to Mr. A. E. Scherer (CE), dated July 31,1986,
" Safety Evaluation of Combustion Engineering ECCS Large Break Evaluation Model and Acceptance for Referencing of Related Licensmg Topical Reports (Approval of CENPD-133, Supplement 5 and CENPD-134, Supplement 2)
-(27). CENPD-135, Supplement 5-P, "STRIKIN-II, A Cylindrical Geometry Fuel Rod Heat Transfer Program," April 1977 (Methodology for Specifications 3.2.1,3.2.2)
'Calvert Cliffs 2, Cycle 13 COLR Page 21 of 23 Rev.O e
[4 (28)
Letter from Mr. R. L. Baer (NRC) to Mr. A. E. Scherer (CE) dated September 6,1978,
" Evaluation of Topical Report CENPD-135, Supplement 5" (29)
CENPD-137, Supplement 1-P, " Calculative Methods for the C-E Small Break LOCA Evaluation Model," January 1977 (Methodology for Specifications 3.2.1,3.2.2)
(30) CENPD-133, Supplement 3-P, "CEFLASH-4AS, "A Computer Program for the Reactor Blowdown Analysis of the Small Break Loss of Coolant Accident," January 1977 l
(Methodology for Specifications 3.2.1,3.2.2) l.
(31)
Letter from Mr. K. Kniel (NRC) to Mr. A. E. Scherer (CE), dated September 27,1977,
" Evaluation of Topical Reports CENPD-133, Supplement 3-P and CENPD-137, Supplement 1-P" (32)
CENPD-138, Supplement 2-P, " PARCH, A FORTRAN-IV Digital Program to Evaluate Pool Boiling, Axial Rod and Coolant Heatup," January 1977 (Methodology for Specifications 3.2.1,3.2.2)
(33)
Letter from Mr. C. Aniel (NRC) to Mr. A. E. Scherer, dated April 10,1978. " Evaluation of Topical Report CENPD-138, Supplement 2-P" (34)- Letter from Mr. A. E. Lundvall, Jr. (BG&E) to Mr. J. R. Miller (NRC) dated February 22, 1985, "Calvert Cliffs Nuclear Power Plant Unit 1; Docket No. 50-317, Amendment to Operating License DPR-53, Eighth Cycle License Application" (Section 7.3.2 contains Methodology for Specifications 3.1.1 and 3.1.3 and 3.1.6)
(35)
Letter from Mr. D. H. Jaffe (NRC) to Mr. A. E. Lundvall, Jr. (BG&E), dated May 20, 1985," Safety Evaluation Report Approving Unit 1 Cycle 8 License Application" (36)
Letter from Mr. A. E. Lundvall, Jr. (BG&E) to Mr. R. A. Clark (NRC), dated September 22,1980, " Amendment to Operating License No. 50-317, Fifth Cycle License Application"(Section 7.1.2 contains Methodology for Specifications 3.1.1,3.9.1) l (37)
L'etter from Mr. R. A. Clark (NRC) to Mr. A. E. Lundvall, Jr. (BG&E), dated December 12,1980, " Safety Evaluation Report Approving Unit 1, Cycle 5 License Application" (38)
Letter from Mr. J. A. Tiernan (BG&E) to Mr. A. C. Thadani (NRC), dated October 1, 1986, "Calvert Cliffs Nuclear Power Plant Unit Nos.1 & 2, Docket Nos. 50-317 &
50-318, Request for Amendment" (Methodology for Specifications 3.1.4)
(39) ' Letter from S. A. McNeil, Jr. (NRC) to Mr. J. A. Tiernan (BG&E), dated July 7,1987, Docket Nos. 50-317 and 50-318, Approval of Amendments 127 (Unit 1) and 109 (Unit 2)
(Support for Specification 3.1.4)
(40)
CENPD-188-A,"HERMITE: A Multi-Dimensional Space-Time Kinetics Code for PWR Transients," July 1976 (Methodology for Specifications 3.3.1,3.1.6,3.2.1,3.2.2, 3.2.3, 3.2.5) l l
l Calvert Cliffs 2. Cycle 13 COLR Page 22 of 23 Rev.O
a (41)
The power distribution monitoring system referenced in various specifications and the BASES, is described in the following documents:
i.
CENPD-153-P, Revision 1-P-A, " Evaluation of Uncertainty in the Nuclear Power Peaking Measured by the Self-Powered, Fixed Incore Detector System," May 1980 (Methodology for Specifications 3.3.1,3.1.6,3.2.1,3.2.2,3.2.3,3.2.5) ii.
CEN-119(B)-P, "BASSS, Use of the Incore Detector System to Monitor the DNB-LCO on Calvert Cliffs Unit I and Unit 2," November 1979 (Referenced in Appendix B of Unit 2 Cycle 9 License Application) lii.
Letter from Mr. G. C. Creel (BG&E) to NRC Document Control Desk, dated February 7,1989, "Calvert Cliffs Nuclear Power Plant Unit No. 2; Docket No. 50-318, Request for Amendment, Unit 2 Ninth Cycle License Application" (Appendix B contains Methodologies for Specifications 3.1.4,3.2.2,3.2.3,3.2.5) iv.
Letter from Mr. S. A. McNeil, Jr. (NRC) to Mr. G. C. Creel (BG&E), dated January 10,1990, " Safety Evaluation Report Approving Unit 2 Cycle 9 License Application" (42)
Letter from Mr. D. G. Mcdonald, Jr. (NRC) to Mr. R. E. Denton (BGE), dated May 11, 1995," Approval to Use Convolution Technique in Main Steam Line Break Analysis -
Calvert Cliffs Nuclear Power Plant, Unit Nos. I and 2 (TAC Nos. M90897 and M90898)"
(Methodology for Specification 3.2.3).
l 1
~
Calvert Cliffs 2, Cycle 13 COLR Page 23 of 23 Rev.O L