._ _

.s - -

~

- lRegul: tory Fila Cy,

"" ~

(' ,

n-b ,.p' .--

sc h M.r, D

\

',  ; 2.".T:t

.>a se..n. w. we..n \ _' '

  • 7 <' <r v,e. eres,a.nr '

General Omces. 212 West Micnigan Avenue. Jackson. Michsgan 49201 e Area Coce $17 788-0550 January 22, 19'74 MIDIAliD PINIT .-- %

Safety Analyses N Docket Nos 50-329 and 50-330 , ,

Mr. A. Giambusso, Deputy Director Reactor Projects

[ (/,

t. JANOS MP -

Directorate of Licensing Office of Regulation

@Q ***$Y Q . hg

__h d

b c., maa uEast tyj k '

US Atcmic Energy Comm4ssion '

61 - h W tat wm g

.z d c)

Washington, DC 20543

/'

%g. .

e

/ p /

.g~e

Dear Mr. Gianbusso:

b h/

e/r[TiB Babcock & Wilcox has notified us oI a change they are making in the specific heat curve for UO2 fuel as utili::ed in some of their transient computer codes. This change will be reflected in the higher value of the specific heat for elevated fuel temperatures.

The studies necessary to quantify the i= pact that this revi-sion may have on the safety analyses reported in the Preliminary Safety Analysis Report are under way. The general effect will be a change in the level of stored energy of fuel as well as in the time response of some transients. 3ased on Babcock & Wilcom's present evaluation, this revision will not affect the steady state analysis because the basic data from which the curve is derived are valid. It is these basic data that are used for the steady state calculations. The particular effect on kinetic behavior is determined only by an evaluation of the safety analyses. To indicate the magnitude of this revision, preliminary calcu-lations on Oconee 2 show that a reduction in the maximum linear heat rate of less than 1.0 MT/ft should offset the effects of this cir.nge in the specific heat.

We will revise the safety analyses to reflect these changes and submit the revised analyses with the Final Safety Analysis Report. We understand that 3abcock & Wilcox will be discussing this information with you on a generic basis in an effort to keep you fully informed of further developments.

Yours very tray, m _g- - ,

_3 3-~.-

s  %-

~

Sh3/sjb 8006090 [20

) -

~ #

" AEC P"9TRIEUTION FOR P ART 50 DOCKET P'7 RIAL (TD!PORARY F0Tdi) CONTROL NO: 720 FILE:

4 FROM: DATE OF DOC DATE REC'D LTR MD10 RPT OTHER Consumers Power Company Jackson, Michigan Stephan H. Howell 1-22-74 1-25-74 X TO: ORIG CC OTHER SENT AEC PDR XXX A Giambusso 1 signed CLASS UNCLASS PROP INFO IITPUT NO CYS REC'D DOCKET NO:

XXX 1 " 30 DESCRIPIION: ENCLCSU?SS:

Ltr advising that, changes in the specific heat curve for UO2 fuel will be submitted TA N0i L.sm ,/2 with the FSAR ---

PLANT NAME: MIDLAND UNITS 1 & 2

%CKNOWLEDGED FOR ACTION /INTOM'.ATION 1-28-74 GMC BUTLER (L) SCIL'ENCER(L) ZIDIANN(L) REGAN(E)

W/ Copics W/4 Copies W/ Copies W/ Copies CL/Kd(L) S10LZ(L) DICl2R(E)

W/ Copics W/ Copies W/ Copies W/ Copies GOLLER(L) VASSALLO(L)- KNIGHION(E)

W/ Copics W/ Copics f / Copics W/ Ccpics 101IEL(L) SCHDIEL(L) W YOUNG 3LOOD(E)

W/ Copics W/ Copics W/1 Copics info W/ Copies

/

INTE2"AL DISTRIEUTIO" W" "(2) /JECH REVIDI DE'; TON A/T 7"D JAEC PDR' (2) #HENDRIE GRIMES LIC ASST ggg77,;33 OGC, ROOM P-500A SCHRCEDER GA121ILL DIGGS (L) SALEMAN MUNIZING/ STAFF MACCARY KAST"ER jGEARIN (L) B. HURT ASE 12:IGilT BALLARD (GOULEQURNE (L) gggg GI/11BUSSO PAULICKI SPANGLER LEE (L)

BOYD SHA0 VMCDONALD MAIGRET (L) DUBE w/ Input

. MCORE (L)(ENR) STELLO jENVIRO SERVICE (L)

DEYOUNG(L)(PWR) liOUSTON VMULLER SHEPPARD (E) INFO SKOVHOLT (L) NOVAK DICKER SMITH (L) C. !!ILES P. COLLINS ROSS KNIGHTON TEETS (L)- B. KING DENISE IPPOLITO YOU"GELOOD WADE (E)

EG OPR TEDESCO REGAN WILLIAMS (E)

FILE & REGION (2) LONG PROJECT LDR WILSON (L)

MORPlS LAINAS .

STEELE BENAROYA HARLESS VOL12'ER ,

/ EXTER"AL DISTRIBUTION (.,6 V1 - LOCAL PDR _ MIDLAND, MICH 1 - DTIE(AU::R'iATHY) (1)(2)(10)-NATIONAL LAB'S 1-PDR-SAN /LA/NY a

1 - USIC(EUCHA"AN) 1-ASLBP(E/W Eld;;,Rm 529) 1-GERALD LELLCUCI'E 1 - ASLB(YORE /SAYRE/ l-W. PENNI"GTON, Rm E-201 GT BR00:2AVEN NAT. LAB WOODARD/"It" ST. 1-CONSULTANT' S 1-AGMED(Ruth Gussmac 16 - CYS ACRS HOLDING NEWMARK/DLL*ME/AGBABIAN 101- B-127, GT.

T 1-GERALD ULRIKSON. . .ORNL 1-RD.. MULLER..F-309

-