ML19323B828
ML19323B828 | |
Person / Time | |
---|---|
Site: | 05000128 |
Issue date: | 04/01/1980 |
From: | Madsen G NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV) |
To: | Berg R TEXAS A&M UNIV., COLLEGE STATION, TX |
Shared Package | |
ML19323B829 | List: |
References | |
NUDOCS 8005140313 | |
Download: ML19323B828 (2) | |
Similar Documents at 05000128 | |
---|---|
Category:CORRESPONDENCE-LETTERS
MONTHYEARML20211Q4001999-09-0707 September 1999
[Table view]Forwards Final Version of Nuclear Science Ctr TS Pending Official Approval from Nrc.Revised TS Simply Incorporates Changes That Were Proposed in Previous Ltrs with Exception of Minor Mod ML20209F0171999-07-0909 July 1999 Forwards Insp Rept 50-128/99-201 on 990608-10.No Safety or Noncompliance Concerns Identified.Various Aspects of Reactor Health Physics & Safeguards Programs Inspected ML20195J4391999-06-10010 June 1999 Forwards Initial Exam Rept 50-128/OL-99-01 Administered During Wk of 990405 to Employees of Facility Who Had Applied for License to Operate Texas A&M Univ Reactor ML20195J9881999-06-10010 June 1999 Forwards Results of Operator Initial Exam Conducted at Texas A&M Univ on 990405-06.Without Encl ML20205R2391999-04-14014 April 1999 Informs That DOE Was Unable to Fund Conversion of Tx A&M Univ Nuclear Science Center Reactor to Low Enrichment U Fuel in FY98 ML20202J6071999-02-0404 February 1999 Advises of Arrangements Made with a Sanchez for Administration of Operator Licensing Exam Wk of 990329. Forwards Ref Matl for RSO & RO Licensing Exam,Administration of Written Exam & Procedures for Administration of Exam ML20197H0921998-12-0808 December 1998 Forwards Insp Rept 50-128/97-201 on 971103-05 & 981102-05.No Significant Safety Issues Were Identified & No Reply Required ML20155A4221998-10-22022 October 1998 Forwards Comment on Rev to Nuclear Science Center Physical Security Plan Submitted by Ltr Dtd 980916.Use Guidance Provided in Reg Guide 5.59 to Address Development of Rev to Security Plan in Response to Comments ML20154L2231998-10-14014 October 1998 Forwards RO License Certificate for CM Lemons,Newly Licensed Individual at Texas A&M Univ ML20153C9791998-09-22022 September 1998 Forwards Copy of Results of Operator Initial Exam Conducted at Texas A&M Univ on 980914.Without Encl ML20154F5391998-09-22022 September 1998 Forwards Inital Exam Rept 50-128/OL-98-02 Administered During Week of 980914 to Employee of Facility Who Applied for License to Operate Texas A&M Univ Reactor ML20153B7501998-09-16016 September 1998 Informs That Nuclear Science Ctr Has Reviewed & Revised Physical Security Plan to Fully Implement NRC Comments & Recommendations,With Exception of One General Comment. Encl Withheld ML20237D6541998-08-20020 August 1998 Discusses Arrangements Made W/A Sanchez,For Administration of Operating Licensing Exams at Texas A&M Univ During Wk of 980914.Matl Furnished for Exam Administered in May 1998 Will Be Used ML20236Q3181998-07-0909 July 1998 Forwards Comments Re Rev to Nuclear Science Ctr Physical Security Plan.Comments Requested to Be Included in Rev to Plan ML20236N0041998-06-22022 June 1998 Forwards SRO Certificates to B Correll,P Pratt & J Stone. W/O Encls ML20249A6101998-06-12012 June 1998 Informs That During Week of 980525,NRC Administered Initial Exam to Employees of Facility Who Applied for License to Operate Texas A&M University Reactor ML20249A6291998-06-12012 June 1998 Forwards Copy of Results of Operator Initial Exam Conducted at Texas A&M Univ on 980526-28.W/o Encl ML20249A6081998-06-11011 June 1998 Forwards Request for Addl Info Re 980126 Application for Amend to Texas A&M Triga Research Reactor License Dealing W/Production of I-125 ML20217M7531998-03-30030 March 1998 Informs That DOE Will Be Unable to Fund Conversion of Texas A&M Univ Nuclear Science Ctr Reactor to Low Enrichment U Fuel in FY97,IAW 10CFR50.64 ML20217F1801998-03-24024 March 1998 Informs That Ltr Submitted W/Nuclear Science Reactor Physical Security Plan Failed to Mention That Changes to Plan Do Not Reduce Effectiveness of Plan & Plan Submitted IAW 10CFR50.90 ML20217Q0831998-03-0202 March 1998 Forwards Nuclear Science Ctr Physical Security Plan.Changes on Copy Designated by Black Vertical Lines in Right Margin. Encl Withheld ML20203J0521998-02-25025 February 1998 Informs That Data Contained in Pages 2,3 & 4 of License Amend Application Submitted by Will Be Withheld from Public Disclosure,Per 10CFR2.790 ML20202G2151998-02-0808 February 1998 Requests That Specific Parts of SE Accompanying 980126 Request for Amend to TS Be Withheld from Public Disclosure Per 10CFR9.17 & 10CFR2.790 ML20199J2841998-01-29029 January 1998 Transmits SRO License Certificate to Th Fisher.W/O Encl ML20199K5241998-01-29029 January 1998 Forwards Revised Ts,Including Minor Changes Made to Sections 3.5.2,6.6.1.f.1 & 6.6.2 ML20199D7801998-01-23023 January 1998 Forwards Revised Safeguard Contingency Plan for Nuclear Science Ctr at Tx A&M Univ,Per 10CFR50.54(p).Changes Do Not Reduce Effectiveness of Security Plan.W/O Encl ML20199C1941997-11-13013 November 1997 Forwards Senior Reactor Operator License Certificates to AB Caldwell & Bk Correll.W/O Encl ML20199B2141997-11-0303 November 1997 Confirms Arrangements Between W Eresian & a Sanchez for Administration of Operator Licensing Exam.Final Applications Certifying Training Must Be Completed & Submitted at Least 14 Days Before First Exam Date ML20211A7141997-09-17017 September 1997 Forwards Signed Amend 19 to Indemnity Agreement E-12 ML20216E9741997-09-0404 September 1997 Forwards Results of Operators Initial Exam Conducted at Facility on 970825-26.W/o Encl ML20149F3461997-07-15015 July 1997 Forwards Amend 19 to Indemnity Agreement E12,amend 14 to License R-83 & Se.Amend Modifies License Conditions to Allow Greater Flexibility in Possession & Storage of Radioactive Matls Used to Support Research & Development within Site ML20141C6271997-06-16016 June 1997 Responds to NRC Ltr Re Violations Noted in Insp Rept 50-128/97-01 on 970317-21.Corrective Actions:Requalification Program Implementation Responsibility Has Been Assigned to Individual Designated as Reactor Administrative Assistant ML20140D2811997-06-0404 June 1997 Informs of Arrangements Made for Administration of Operator Licensing Exams for Wk of 970825.Ref Matls for Exam,Facility Review of Written Exams,Administration of Written Exams & Procedures for Administration of Written Exams Encl ML20148F1151997-05-29029 May 1997 Forwards Insp Rept 50-128/97-01 on 970317-21 & Notice of Violation.Nrc Will Use Facility Response to Determine Whether Further Enforcement Action Will Be Needed.Mgt Meeting W/Nrc Scheduled for 970619 to Discuss Insp Findings ML20138C8741997-04-25025 April 1997 Informs That DOE Will Be Unable to Fund Conversion of Texas A&M Univ Nuclear Science Ctr Reactor to Low Enrichment U Fuel in FY97 ML20137Y0301997-04-16016 April 1997 Forwards Rev 4 to Nuclear Science Center Senior Reactor Operator & Reactor Operator Requalification Program ML20137T9251997-04-11011 April 1997 Forwards Reactor Operator License Certificate to Dj Beckel, Newly Licensed Individual at Texas Engineering Experiment Station Reactor.W/O Encl ML20137L3321997-04-0303 April 1997 Forwards Retaken Exam Rept 50-128/OL-97-01 on 970324.Exam Administered to Employee,To Operated Texas A&M Triga Reactor ML20137R4221997-04-0303 April 1997 Forwards Results of Operator Initial Exam Conducted at Facility on 970324.W/o Encl ML20137C9001997-03-19019 March 1997 Forwards Reactor Operator License Exam,Category B,To Be Administered to D Beckel on 970324.Pre-exam & post-exam Security Agreement Also Encl for Signature & to Be Returned W/Exam Matls ML20135D5391997-02-25025 February 1997 Requests That Indemnity Agreement E-12 Be Changed as Listed ML20147E2351997-02-13013 February 1997 Forwards Reactor Operator License Certificates to Listed Individuals.W/O Encl ML20135E9411996-12-0909 December 1996 Forwards Initial Exam Rept 50-128/OL-96-02 Administered to Employees Who Had Applied for License to Operate Texas A&M Reactor During Wk of 961118 ML20135D8671996-12-0606 December 1996 Forwards Results of Operator Initial Exam Conducted on 961119-21.W/o Encl ML20135E1591996-12-0505 December 1996 Ack Receipt of Informing NRC of Steps Taken to Correct Violations Noted in Insp of License R-83 ML20134M7061996-11-21021 November 1996 Forwards Request for Addl Info,In Order to Complete Review of 960715 Application to Increase Power Level of Texas A&M Univ Sys Nuclear Science Center Reactor Up to 1,500 Kilowatts ML20134L6851996-11-18018 November 1996 Forwards Certificates to Two Newly Licensed Individuals at Texas A&M University System.W/O Encls ML20129A8591996-10-17017 October 1996 Informs NRC of Reportable Occurrence Re Violation of Tech Specs LCO on 961015.Automatic Ventilation Sys Shutdown Bypassed During Air Monitor Check Prior to Reactor Startup ML20129F0981996-09-27027 September 1996 Informs of Arrangements Made W/B Asher for Administration of Operator Licensing Exam During Wk of 961118 ML20115D0351996-07-0808 July 1996 Informs NRC That Name of Level 1 Licensee for Tx A&M Univ Sys/Tx Engineering Experiment Station Nuclear Science Ctr, Now Bd Russell,Effective 960701 1999-09-07 Category:NRC TO EDUCATIONAL INSTITUTION MONTHYEARIR 05000128/19900021990-05-30030 May 1990
[Table view]Ack Receipt of Informing NRC of Steps Taken to Correct Violations & Deviations Noted in Insp Rept 50-128/90-02 ML20034C1141990-04-17017 April 1990 Forwards Insp 50-128/90-02 on 900221-23 & Notice of Violation & Deviation ML20034A5291990-04-16016 April 1990 Requests Util Provide Ref Matls Listed in Encl for Licensing Exam Scheduled for Wk of 900625.Completed Operator License Applications Must Be Submitted 30 Days Before First Exam Date ML20033F3661990-03-0808 March 1990 Provides Corrected Listed Info to Insp Rept 50-128/90-01,per 900227 Telcon ML20012A1081990-02-21021 February 1990 Forwards Insp Rept 50-128/90-01 on 900110-12.Violations Noted.Nrc Concerned Re Vacant Position for Nuclear Science Ctr Physicist ML20042D2061990-01-0202 January 1990 Forwards Amend 12 to License R-83 & Safety Evaluation.Amend Modifies Organizational Structure & Changes Name of Licensee to Texas Engineering Experiment Station/Texas A&M Univ Sys Instead of Texas A&M Univ ML20011D4681989-12-18018 December 1989 Advises That Licensing Exams Will Be Administered During Wk of 900305.Ref Matl,Listed on Encl,Should Be Provided by 891230 & Completed Reactor Operator & Senior Reactor Operator Applications Should Be Sent 30 Days Prior to Exam ML20248C3591989-08-0101 August 1989 Advises of Reactor & Senior Reactor Operator Licensing Exams Scheduled for Wk of 891030.Ref Matl Requirements, Requirements & Procedures for Administration of Written Exams & Requirements for Facility Review Encl ML20245J3411989-05-0101 May 1989 Advises That Reactor Operator Exams Scheduled for Wk of 890612.Encl Ref Matl Requested by 890512 in Order to Meet Schedule ML20154K9221988-09-20020 September 1988 Ack Receipt of & Check in Payment for Civil Penalties in Amount of $5,000.Ack Receipt of 880728 Response to Notice of Violation ML20151V0661988-08-11011 August 1988 Confirms NRC Agreement to Extend Response to 880713 Notice of Violation Until 880901,per G Sanborn 880810 Request ML20151F0291988-07-13013 July 1988 Discusses Insp Repts 50-128/88-01 & 50-128/88-03 on 880307- 09 & 0411-12 & Forwards Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $5,000.Violations Indicate Failure to Exercise Adequate Mgt Control ML20195C2541988-06-13013 June 1988 Forwards Insp Rept 50-128/88-03 on 880411-12.Violations Will Be Addressed in Separate Correspondence ML20195D6401988-06-10010 June 1988 Advises That Term Explosive Matls Used in Tech Specs Means Class a Explosives Per DOT Regulation 49FR Chapter 1. Matls Not Defined as Class a Explosives Must Be Reviewed Per Tech Spec Section 4.6 Prior to Being Placed in Reactor ML20153G1501988-05-0505 May 1988 Forwards Insp Rept 50-128/88-02 on 880405-07.No Violations or Deviations Noted ML20151T9401988-04-21021 April 1988 Forwards Summary of 880405 Enforcement Conference in Region 4 Ofc Re Violations Noted in Insp Rept 50-128/88-01 ML20151L6451988-03-23023 March 1988 Forwards Amend 11 to License R-83 & Safety Evaluation.Amend Modifies Title of One Position in Organizational Structure for Station ML20148J0101988-03-17017 March 1988 Confirmatory Action Ltr 88-03 Re 880316 Conversation That Listed Actions Being Taken in Response to Concerns in Insp on 880306-09.Nuclear Science Ctr Reactor Safety Committee Will Perform Detailed Review If Neutron Diffraction Studies ML20237D4161987-12-16016 December 1987 Confirms That Operator Licensing Exams Scheduled for Wk of 880229.Util Should Make Available at Site Approved Ref Matl Listed in Encl 1 by 880115.Exam Requirements Also Encl ML20236G0771987-10-26026 October 1987 Confirms That Jl Pellet Will Assume Position & Duties of Section Chief of Operator Licensing Section in Div of Reactor Safety Effective on 871025 to Replace R Cooley ML20215A7111987-06-11011 June 1987 Ack Receipt of Util 870408 & 0512 Ltrs Responding to 870311 Notice of Violation & NRC 870311 & s & Informing NRC of Corrective Actions Re Violations.One Violation Withdrawn & Second to Be Reviewed During Insp ML20215D2031987-06-11011 June 1987 Informs That T Micheal Assigned as Project Manager for Facility Due to NRR Reorganization IR 05000128/19870011987-04-28028 April 1987 Ack Receipt of Informing NRC of Steps Taken to Correct Violations Noted in Insp Rept 50-128/87-01.Requests Records Substantiating That Bromine Experiment Reviewed by Nuclear Science Ctr Before Bromine Irradiated in Reactor ML20205Q6601987-03-30030 March 1987 Informs That 870224 Request to Modify Emergency Plan Changing Annual Renewal of Agreements W/Offsite Support Agencies to Multiple Yr or Open Renewal Would Decrease Effectiveness of Plan & Unacceptable ML20212P5401987-03-11011 March 1987 Forwards Insp Rept 50-128/87-01 on 870112-14 & Notice of Violation.One Unresolved Item Identified in Paragraph 4.g of Rept ML20212A1821987-02-24024 February 1987 Advises That Applications for Reactor Operator & Senior Operator Licensing Exam Scheduled for 870330 Received in Timely Manner.List of Ref Matl Requirements for Exam & Requirements for Administration of Written Exams Encl ML20207N9581987-01-12012 January 1987 Forwards Order Imposing Civil Monetary Penalty in Amount of $833 Based on 860918 Responses to 860722 Notice of Violation & Proposed Imposition of Civil Penalty Re 860505 Insp. Violation C Withdrawn & Violations a & B Reclassified ML20214M4391986-09-0404 September 1986 Forwards Insp Rept 50-128/86-02 on 860729-30.No Violations or Deviations Noted.Status of Items Identified During Previous Insp Findings Examined ML20206Q2131986-08-27027 August 1986 Forwards Environ Assessment & Notice of Finding of No Significant Environ Impact Re 860711 Proposed Amend to License R-83 to Increase Mass for Fueled Experiments IR 05000128/19860061986-08-20020 August 1986 Grants 30-day Extension Until 860922 for Reply to 860722 Notice of Violation & Proposed Imposition of Civil Penalty Re Insp Rept 50-128/86-06 & EA-86-105,per 860811 Request ML20211Q9701986-07-22022 July 1986 Discusses Insp on 860505 & Forwards Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $1,250. Confirmation of Action Ltr Transmitted on 860507 & Enforcement Conference Conducted on 860521 ML20198A0661986-05-15015 May 1986 Forwards Insp Rept 50-128/86-01 on 860505 & Notice of Violation.Enforcement Conference Scheduled on 860521 to Discuss Violations,Reasons & Corrective Actions.Concern Expressed Re Lack of Discipline Exhibited by Staff ML20210H9271986-03-27027 March 1986 Lists Change in Telephone Number for H Bernard,Facility Project Manager,Due to NRR Reorganization.D Tondi New Nonpower Reactors & Safeguards Licensing Section Leader. Correspondence Should Be Sent to Listed Address ML20138N0611985-12-17017 December 1985 Discusses NRC 850927 Order to Show Cause Why All Excess High Enriched U Fuel Should Not Be Removed to Secure Facility Away from Reactor Site.Consent to Order Understood, Since Hearing Not Requested,Nor Order Contested ML20133F8751985-10-0808 October 1985 Forwards Chronology of Commission Approved Physical Security Plan for Texas A&M Univ AGN-201M Reactor Facility IR 05000128/19820031983-05-0404 May 1983 Ack Receipt of Informing NRC of Steps Taken to Correct Violations Noted in IE Insp Rept 50-128/82-03 ML20058B4721982-07-16016 July 1982 Forwards Amend 8 to License R-83.Amend Changes Tech Specs Re Administrative Organizational Controls ML20054M4011982-07-0808 July 1982 Forwards IE Insp Rept 50-128/82-01 on 820604.No Noncompliance Noted ML20054L3881982-06-16016 June 1982 Ltr to All Research & Test Reactor Licensees Requesting That Reg Guide 2.6 (for Comment) & ANSI/ANS-15.16 (Draft II Dtd 811129) Be Used to Meet Requirement of Final Amend to 10CFR50.54(r) Re Emergency Planning.Fr Notice Encl ML20052D6371982-04-16016 April 1982 Ack Receipt of Pertaining to Concern of Training, Research & Test Reactor Community About NRC Proposed Amends to Physical Security Requirements for Nonpower Reactor Licensees IR 05000128/19810021982-02-0202 February 1982 Forwards IE Insp Rept 50-128/81-02 on 811207-10.No Noncompliance Noted.Major Areas Inspected:Programs & Activities to Protect Against Industrial Sabotage & to Safeguard Snm.Insp Rept Withheld (Ref 10CFR73.21) ML20032C7391981-10-13013 October 1981 Forwards Fr Notice & Press Release Re Proposed Addl Safeguards for Research Reactors ML20010B9741981-07-31031 July 1981 Forwards IE Info Notice 81-22, Sections 235 & 236 Amend to Atomic Energy Act of 1954. Info Should Be Brought to Attention of Employees.No Other Action Required IR 05000128/19810011981-06-0303 June 1981 Forwards IE Insp Rept 50-128/81-01 on 810507-08.No Noncompliance Noted.Insp Rept Withheld (Ref 10CFR2.790) ML19350B3391981-02-0909 February 1981 Forwards IE Circular 81-02, Performance of NRC-Licensed Individuals While on Duty. No Written Response Required ML19331C0911980-06-24024 June 1980 Forwards IE Circular 80-14, Radioactive Contamination of Plant Demineralized Water Sys & Resultant Internal Contamination of Personnel. No Response Required IR 05000128/19800011980-05-30030 May 1980 Ack Receipt of 800414 & 0523 Ltrs Informing NRC of Steps Taken to Correct Violations Noted in IE Insp Rept 50-128/80-01 ML19323G4591980-05-15015 May 1980 Ack Receipt of in Response to NRC & Notice of Violation.Requests Addl Info to Properly Evaluate Adequacy of Corrective Action,Including Corrective Steps Taken,Results & Steps Taken to Avoid Further Violations ML19323B8281980-04-0101 April 1980 Forwards IE Insp Rept 50-128/80-01 on 800304-06 & Notice of Violation ML19344D1381980-02-0101 February 1980 Forwards IE Circular 80-02, Nuclear Power Plant Staff Work Hours. No Written Response Required 1990-05-30 Category:OUTGOING CORRESPONDENCE MONTHYEARML20209F0171999-07-0909 July 1999
[Table view]Forwards Insp Rept 50-128/99-201 on 990608-10.No Safety or Noncompliance Concerns Identified.Various Aspects of Reactor Health Physics & Safeguards Programs Inspected ML20195J4391999-06-10010 June 1999 Forwards Initial Exam Rept 50-128/OL-99-01 Administered During Wk of 990405 to Employees of Facility Who Had Applied for License to Operate Texas A&M Univ Reactor ML20195J9881999-06-10010 June 1999 Forwards Results of Operator Initial Exam Conducted at Texas A&M Univ on 990405-06.Without Encl ML20202J6071999-02-0404 February 1999 Advises of Arrangements Made with a Sanchez for Administration of Operator Licensing Exam Wk of 990329. Forwards Ref Matl for RSO & RO Licensing Exam,Administration of Written Exam & Procedures for Administration of Exam ML20197H0921998-12-0808 December 1998 Forwards Insp Rept 50-128/97-201 on 971103-05 & 981102-05.No Significant Safety Issues Were Identified & No Reply Required ML20155A4221998-10-22022 October 1998 Forwards Comment on Rev to Nuclear Science Center Physical Security Plan Submitted by Ltr Dtd 980916.Use Guidance Provided in Reg Guide 5.59 to Address Development of Rev to Security Plan in Response to Comments ML20154L2231998-10-14014 October 1998 Forwards RO License Certificate for CM Lemons,Newly Licensed Individual at Texas A&M Univ ML20154F5391998-09-22022 September 1998 Forwards Inital Exam Rept 50-128/OL-98-02 Administered During Week of 980914 to Employee of Facility Who Applied for License to Operate Texas A&M Univ Reactor ML20153C9791998-09-22022 September 1998 Forwards Copy of Results of Operator Initial Exam Conducted at Texas A&M Univ on 980914.Without Encl ML20237D6541998-08-20020 August 1998 Discusses Arrangements Made W/A Sanchez,For Administration of Operating Licensing Exams at Texas A&M Univ During Wk of 980914.Matl Furnished for Exam Administered in May 1998 Will Be Used ML20236Q3181998-07-0909 July 1998 Forwards Comments Re Rev to Nuclear Science Ctr Physical Security Plan.Comments Requested to Be Included in Rev to Plan ML20236N0041998-06-22022 June 1998 Forwards SRO Certificates to B Correll,P Pratt & J Stone. W/O Encls ML20249A6101998-06-12012 June 1998 Informs That During Week of 980525,NRC Administered Initial Exam to Employees of Facility Who Applied for License to Operate Texas A&M University Reactor ML20249A6291998-06-12012 June 1998 Forwards Copy of Results of Operator Initial Exam Conducted at Texas A&M Univ on 980526-28.W/o Encl ML20249A6081998-06-11011 June 1998 Forwards Request for Addl Info Re 980126 Application for Amend to Texas A&M Triga Research Reactor License Dealing W/Production of I-125 ML20203J0521998-02-25025 February 1998 Informs That Data Contained in Pages 2,3 & 4 of License Amend Application Submitted by Will Be Withheld from Public Disclosure,Per 10CFR2.790 ML20199J2841998-01-29029 January 1998 Transmits SRO License Certificate to Th Fisher.W/O Encl ML20199C1941997-11-13013 November 1997 Forwards Senior Reactor Operator License Certificates to AB Caldwell & Bk Correll.W/O Encl ML20199B2141997-11-0303 November 1997 Confirms Arrangements Between W Eresian & a Sanchez for Administration of Operator Licensing Exam.Final Applications Certifying Training Must Be Completed & Submitted at Least 14 Days Before First Exam Date ML20216E9741997-09-0404 September 1997 Forwards Results of Operators Initial Exam Conducted at Facility on 970825-26.W/o Encl ML20149F3461997-07-15015 July 1997 Forwards Amend 19 to Indemnity Agreement E12,amend 14 to License R-83 & Se.Amend Modifies License Conditions to Allow Greater Flexibility in Possession & Storage of Radioactive Matls Used to Support Research & Development within Site ML20140D2811997-06-0404 June 1997 Informs of Arrangements Made for Administration of Operator Licensing Exams for Wk of 970825.Ref Matls for Exam,Facility Review of Written Exams,Administration of Written Exams & Procedures for Administration of Written Exams Encl ML20148F1151997-05-29029 May 1997 Forwards Insp Rept 50-128/97-01 on 970317-21 & Notice of Violation.Nrc Will Use Facility Response to Determine Whether Further Enforcement Action Will Be Needed.Mgt Meeting W/Nrc Scheduled for 970619 to Discuss Insp Findings ML20137T9251997-04-11011 April 1997 Forwards Reactor Operator License Certificate to Dj Beckel, Newly Licensed Individual at Texas Engineering Experiment Station Reactor.W/O Encl ML20137R4221997-04-0303 April 1997 Forwards Results of Operator Initial Exam Conducted at Facility on 970324.W/o Encl ML20137L3321997-04-0303 April 1997 Forwards Retaken Exam Rept 50-128/OL-97-01 on 970324.Exam Administered to Employee,To Operated Texas A&M Triga Reactor ML20137C9001997-03-19019 March 1997 Forwards Reactor Operator License Exam,Category B,To Be Administered to D Beckel on 970324.Pre-exam & post-exam Security Agreement Also Encl for Signature & to Be Returned W/Exam Matls ML20147E2351997-02-13013 February 1997 Forwards Reactor Operator License Certificates to Listed Individuals.W/O Encl ML20135E9411996-12-0909 December 1996 Forwards Initial Exam Rept 50-128/OL-96-02 Administered to Employees Who Had Applied for License to Operate Texas A&M Reactor During Wk of 961118 ML20135D8671996-12-0606 December 1996 Forwards Results of Operator Initial Exam Conducted on 961119-21.W/o Encl ML20135E1591996-12-0505 December 1996 Ack Receipt of Informing NRC of Steps Taken to Correct Violations Noted in Insp of License R-83 ML20134M7061996-11-21021 November 1996 Forwards Request for Addl Info,In Order to Complete Review of 960715 Application to Increase Power Level of Texas A&M Univ Sys Nuclear Science Center Reactor Up to 1,500 Kilowatts ML20134L6851996-11-18018 November 1996 Forwards Certificates to Two Newly Licensed Individuals at Texas A&M University System.W/O Encls ML20129F0981996-09-27027 September 1996 Informs of Arrangements Made W/B Asher for Administration of Operator Licensing Exam During Wk of 961118 ML20058L3911993-12-13013 December 1993 Forwards Results for Operator Initial Exam Conducted at Facility on 931109.W/o Encl ML20058L3631993-12-0909 December 1993 Forwards Initial Exam Rept 50-128/OL-93-03 Administered During Wk of 931108 ML20058L3611993-12-0909 December 1993 Forwards Initial Exam Rept 50-128/OL-93-03 Administered During Wk of 931108.W/o Encl ML20059F9971993-10-26026 October 1993 Forwards Amend 18 to Indemnity Agreement E-12,amend 13 to License R-83 & Se.Amend Modifies License Conditions to Allow Greater Flexibility in Possession & Storage of Radioactive Matls Used to Support Research & Development ML20056E6161993-08-0909 August 1993 Requests Response to Encl Ref Matl Request for Ro/Sro Licensing Exams Scheduled for 931108.Info on Administration of Written Exams & Rules & Guidelines Also Encl ML20056C4551993-06-0808 June 1993 Forwards Initial Exam Rept 50-128/OL-93-02 on 930518 ML20044G1621993-05-24024 May 1993 Ack Receipt of in Response to Two EP Weaknesses Identified in Insp Rept 50-128/93-01 .Notifies That NRC Acceptance of C/A for Subj Weakness Does Not Constitute Preapproval of Revised Classification Guide ML20035E9461993-04-0909 April 1993 Forwards Insp Rept 50-128/93-01 on 930315-16.No Violations Noted.Listed Weaknesses Identified & Discussed in Encl Rept ML20036B5211993-03-30030 March 1993 Forwards Senior Operator License Certificate to Be Presented to Listed Individual in Recognition of Protecting Public Health & Safety.W/O Encl ML20056C1341993-03-23023 March 1993 Confirms Meeting Between Wd Reece & B Murray on 930428 to Discuss NRC Mgt Personnel Opportunity to Review & Discuss Performance Perspectives of Licensed Activities ML20034H3621993-03-11011 March 1993 Forwards Results of Initial Exam Rept 50-128/OL-93-01 on 930225.W/o Encl IR 05000128/19920021993-01-19019 January 1993 Ack Receipt of Informing NRC of Steps Taken to Correct Violations Noted in Insp Rept 50-128/92-02 ML20044E6131992-10-26026 October 1992 Forwards Certificates for Bs Carlisle & Wd Reece in Recognition of Important Role Licensed Operators Fulfill in Protecting Health & Safety of Public.W/O Encls ML20044E3581992-07-0606 July 1992 Forwards Reactor/Senior Reactor Operator License Certificates for KA Roady & AA Sanchez,Per Commission Request.W/O Encl ML20044B5051992-04-0606 April 1992 Transmits SRO License Certificates for Th Fisher & Mh Guillory,In Recognition of Important Role Licensed Operators Fulfill in Protecting Health & Safety of Public. W/O Encl ML20029B3671991-03-0101 March 1991 Advises That Change to Add Physical Security Training to Operator Requalification Program,Acceptable,Per 10CFR55 1999-07-09 |
See also: IR 05000128/1980001
Text
,- -
_-
. _ _ _ .
i
77C
558 "8%
UNITED STATES
2[' -) #
Io,,
NUCLEAR REGULATORY COMMISSION
8005146 3 { 3
.
R EGION IV
n
2 I
o
611 RYAN PLAZA oRIVE,SulTE 1000
5 D.
Aj
ARLINGTON, TEXAS 76012
o, b
g
%, %+..../
April 1, 1980
In Reply Refer to:
Docket No. 50-128/80-01
Texas A&M University
ATTN:
Dr. Robert R. Berg, Director
Office of University Research
College Station, Texas 77843
Gentlemen:
This refers to the inspection conducted by ';. L. Constable and S. R. Dean
of this office, and J. W. Craig of the Inspection and Enforcement Headquarters
staff during March 4-6, 1980, at the Nuclear Science Center of activities
authorized by NRC Operating License No. R-83 and to the discussion of findings
held with Dr. R. R. Berg and other university representatives at the conclusion
cf the inspection.
Areas examined during the inspection and our findings are discussed in the
enclosed inspection report. Within these areas, the inspection consisted of
selective examination of procedures and representative rec 7rds, interviews
with personnel, and observations by the inspectors.
Based on the results of this inspection, it appears that one of your activities
was not conducted in full compliance with NRC requirements. The item and
references to the pertinent requirements are listed in Enclosure i to this
letter. This notice is sent to you pursuant to the provisions of Section
2.201 of the NRC's " Rules of Practice," Part 2, Title 10, Code of Federal
Regulations.
Section 2.201 requires you to submit to this office, within 20
days of your receipt of this notice, a written statement of explanation in
reply including:
(1) corrective steps which have been or will be taken by
you, and the results achieved; (2) corrective steps which will be taken to
avoid further violations; and (3) the date when full compliance will be achieved.
l
I
__
-
,
-2-
In accordance with Section 2.790 of the NRC's " Rules of Practice," Part 2,
Title 10, Code of Federal Regulations, a copy of this letter and the enclosed
inspection report will be placed in the NRC's Public Document Room.
If this
report contains any information that you believe to be proprietary, it is
necessary that you make a written application within 20 days to this office to
withhold sach information from public disclosure.
Any such application must
include a full statement of the reasons it is claimed that the information is
proprietary.
It should be prepared so that proprietary information identified
is contained in a separate part of the document, since the application,
excluding this separate part, will also be placed in the Public Document Room.
If we do not hear from you in this regard within the specified period, the
report will be placed in the Public Document Room.
Should you have any questions concerning this inspection, we will be pleased
to discuss them with you.
Sincerely,
G. L. Madsen, Chief
Reactor Operations and
Nuclear Support Branch
Enclosures:
1.
2.
IE Inspection Report
No. 50-128/80-01
l
1