ML19209A866

From kanterella
Jump to navigation Jump to search
Responds to NRC Re Violations Noted in IE Insp Repts 50-373/78-28 & 50-374/78-20.Corrective Actions: Repair Made to Root of Feedwater safe-end 150-degree Azimuth in Question
ML19209A866
Person / Time
Site: LaSalle  
Issue date: 07/30/1979
From: Reed C
COMMONWEALTH EDISON CO.
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML19209A855 List:
References
NUDOCS 7910050496
Download: ML19209A866 (1)


Text

_ Commonwealth Edison One First National Plaza, Chicago, tilinois Address Reply to: Post Office Box 767 Chicago, Illinois 60690 July 30, 1979 Mr. J. G. Keppler, Director Directorate of Inspection and Enforcement - Region III U.S. Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, Illinois 60137

Subject:

LaSalle County Station Units 1 and 2 Supplemental Response to IE Inspection Report Nos. 50-373/78-28 and 50-374/78-20 NRC Docket Nos. 50-373 and 50-374 Reference (a) :

G. Fiorelli letter to B. Lee, Jr.

dated February 2, 1979

Dear Mr. Keppler:

In order to resolve the open issue relative to weld repair records which was addressed in Reference (a), General Electric Company issued Nonconformance Report (NCR) LSFW1-2 for the feedwater safe-end weld in question.

The resolution of that NCR documents the repair made to the root of that feedwater safe end (150 azimuth).

This documentation is available at LaSalle County Station for review by Region III.

Please direct any additional questions you may have in this regard to this office.

Very truly yours,

&h

/ce/ Cordell Reed Assistant Vice-President i127 153 AUG II9 79100bD09k