Forwards Relief Request RV-57 for Emergency Fuel Pool Makeup Crosstive Vent Valve 1(2)E12-F097.Expedious Review of Request Requested Because Valve 1(2)E12-F097 Inoperable & Will Remain So Until NRC Approval Received
ML20043E865
Person / Time
Site: LaSalle  
Issue date: 06/07/1990
From: Morgan W
COMMONWEALTH EDISON CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
NUDOCS 9006130473
Download: ML20043E865 (2)


Text

  1. .- %

/

\\ Commonw alth Edle:n

-/

) 1400 Opus Pitce-

" } Dowr.;rs Grova, Illinois 60515

\\

- yNs June 7, 1990 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D.C.

20555 l

Subject:

LaSalle County Station Units 1 and 2 In-service Testing Program Relief Request RV-57 NRC Docket Nos. 50-353 and 50-354 r

Reference:

(a) W.E. Morgan letter to T.E. Murley dated October 2, 1989 (LaSalle County Station Units 1 and 2 IST Program Rev. 2).

Dear Sir:

Reference (a) submitted Commonwealth Edison's LaSalle County Station In-service Testing Program Revision 2.

The following attachment provides relief request RV-57 for the Emergency Fuel Pool Makeup Crosstive Vent Valves, 1(2) E12-F097.

For the reasons given in the request, the necessary testing required by ASME Section XI, 1980 Edition through Winter '80' Addenda, cannot be performed.

Commonwealth Edison requests an expedious review of this request because the Valves 1(2) E12-F097 have been declared inoperable, and will remain so until NRC approval is received. Once approval is received, LaSalle

' Station will revise the inservice testing program to incorporate the relief request.

Please direct any question you may have regarding this matter to this q

office.

Very truly yours, W

LN a

W.E. Morgan Nuclear Licensing Administrator cc:

R. Pulsifer - Project Manager, NRR h

j Senior-Resident Inspector - LSCS t

\\

/Imw:1068T

{d DR ADOC 0

F

L g

I Od);

LASALLE COUNTY STATI(N.

IMIT 01'and 2 Page 1 of 1 Vit.W RELIEF EREST/

AppfDML/IEFElBCE DOCl#ENT(s): Not Approved-

. COLD S UTD0lM JUSTIFICATION: RV-57 t

AFFECTED COMP 0ENT(s):

j t

COMPOIUTEpH CLASS / CATE60RY DEllDN 1(2)E12-F097

'3

/ B Feel pool Energency Nakeup Crosstle Vent i -

AGIE SECTION !! TEST EGulROOT: Stroke Time powe Operated Valves, IW-3413.

BASISFORRELIEF: The seergency fuel pool makeup system provides an seergency source of water to the fuel pool and -

also provides contairment f;ooding water for post-accident recovery.. To prevent inadvertent injection of lake mater into the reactor or spent fuel pool, spool pieces are 1nstalled on the outlet of the seergency makeup pumps for isolation. These spool pieces are located in the D6 1

building and can be installed in case of an accident. The seergency makeup line for containment flooding is connected to the 'B' residual heat removal loop via two nereally closed motor operated Date valves (F093 and F094) and a testable check valve (F089). The F097 is a soleniod operated valve installed in the vent line between the F093 and F094 valves. The valve does not have a control switch and is interlocked with the control switches of the F093 and F094.'.Each control switch has a contact in series with the solenled of the F097 valve, which closes when the associated control switch is.in the closed position. There are no position indicator switches that provide for remote indication of valve position. Therefore, there is no way to stroke time the L

valve. Furthermore,thereisnospecificrequiredfunctionalvalteoffull-stroketimeforthe l-valvel as long as the valve closes, its function is demonstrated, y

l

. ALTERNAT!W TEST: perform an exercise test on a quarterly basis per IW-3412 to verify valve operability, s

1:

L