Letter Sequence RAI |
---|
|
Initiation
- Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request
- Acceptance...
- Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement
Results
Other: ML110620203, ML11140A163, ML11224A265, ML11230A003, ML11318A121, ML11318A122, ML11318A123, ML11318A124, ML11318A125, ML11318A126, ML11318A127, ML11318A128, ML11318A129, ML11318A130, ML11318A131, ML11318A132, ML11318A133, ML11318A135, ML11318A136, ML11318A138, ML11318A139, ML11318A140, ML11318A141, ML11318A142, ML11318A143, ML11318A144, ML11318A145, ML11318A146, ML11318A147, ML11318A148, ML11318A149, ML11318A150, ML11318A151, ML11318A152, ML11318A153, ML11318A154, ML11318A155, ML11318A156, ML11318A157, ML11318A158, ML11318A159, ML11318A160, ML11318A161, ML11318A162, ML11318A163, ML11318A164, ML11318A165, ML11318A166, ML11318A167, ML11318A168... further results
|
MONTHYEARML1106202032011-03-17017 March 2011 License Renewal Application Online Reference Portal Project stage: Other ML1108907642011-04-14014 April 2011 Request for Additional Information for the Review of the South Texas Project, License Renewal Application-Electrical Branch Scoping Project stage: RAI ML1108205792011-04-14014 April 2011 Request for Additional Information for the Review of the South Texas Project, License Renewal Application -Section 2.4 Structural (TAC Nos. ME4936, ME4937) Project stage: RAI ML1108309782011-04-14014 April 2011 Request for Additional Information for the Review of the South Texas Project, License Renewal Application, Fire Protection and Component Integrity (TAC Nos. ME4536 ME4637 Project stage: RAI NOC-AE-11002670, Response to Request for Additional Information for License Renewal Application2011-05-0505 May 2011 Response to Request for Additional Information for License Renewal Application Project stage: Response to RAI NOC-AE-11002672, Response to Request for Additional Information for Licence Renewal Application2011-05-12012 May 2011 Response to Request for Additional Information for Licence Renewal Application Project stage: Response to RAI ML11137A0922011-05-24024 May 2011 Request for Additional Information for the Review of the South Texas Project, Units 1 and 2, License Renewal Application Future Consideration of Operating Experience Project stage: RAI ML11140A1632011-06-0606 June 2011 Plan for the Aging Management Program Regulatory Audit Regarding the South Texas Project, Units 1 and 2 License Renewal Application Review (TAC Nos. ME4936 and ME4937) Project stage: Other NOC-AE-11002681, Amendment 2 to the License Renewal Application2011-06-16016 June 2011 Amendment 2 to the License Renewal Application Project stage: Other NOC-AE-11002683, Response to Request for Additional Information for License Renewal Application (TAC Nos. ME4936 and ME4937)2011-06-23023 June 2011 Response to Request for Additional Information for License Renewal Application (TAC Nos. ME4936 and ME4937) Project stage: Response to RAI ML11154A0132011-07-0606 July 2011 Summary of Telephone Conference Call Held on May 23, 2011, Between the NRC and STPNOC, Concerning Requests for Additional Information Pertaining to the South Texas Project, LRA-Future Consideration of Operating Experience Project stage: RAI ML11166A2392011-07-12012 July 2011 Letter Request for Additional Information for South Texas Project Electric Generating Station, Units 1 and 2 License Renewal Application - Scoping and Screening Balance of Plant (TAC Nos. ME4936 and ME4937) Project stage: RAI ML11201A0552011-07-28028 July 2011 Requests for Additional Information for the Review of the South Texas Project, License Renewal Application - Scoping and Screening Audit (TAC Nos. ME4936 and ME4937) Project stage: RAI NOC-AE-11002702, Response to Request for Additional Information for the Review of the South Texas Project License Renewal Application2011-08-0909 August 2011 Response to Request for Additional Information for the Review of the South Texas Project License Renewal Application Project stage: Response to RAI ML11214A0882011-08-15015 August 2011 Request for Additional Information for the Review of the South Texas Project, Units 1 and 2 License Renewal Application - Aging Management Programs Audit, Plant Systems (TAC ME4936 and ME4937) Project stage: RAI ML11214A0052011-08-15015 August 2011 Requests for Additional Information for the Review of the South Texas Project, Units 1 and 2 License Renewal Application - Aging Management Programs Audit, Structures/Electrical (TAC ME4936 and ME4937) Project stage: RAI ML11214A0272011-08-15015 August 2011 Requests for Additional Information for the Review of the South Texas Project, Units 1 and 2 License Renewal Application - Aging Management Programs Audit, Reactor Systems (TAC Nos. ME4936 and ME4937) Project stage: RAI NOC-AE-11002716, Response to Request for Additional Information for the South Texas Project License Renewal Application (TAC ME4936 and ME4937)2011-08-18018 August 2011 Response to Request for Additional Information for the South Texas Project License Renewal Application (TAC ME4936 and ME4937) Project stage: Response to RAI ML1123000162011-08-18018 August 2011 License Renewal - Errata in AMP RAI Package Project stage: RAI NOC-AE-11002714, Response to Request for Additional Information for the South Texas Project License Renewal Application (TAC ME4936 and ME4937)2011-08-23023 August 2011 Response to Request for Additional Information for the South Texas Project License Renewal Application (TAC ME4936 and ME4937) Project stage: Response to RAI ML11230A0032011-09-0606 September 2011 Scoping and Screening Audit Report Regarding the South Texas Project, Units 1 and 2 (TAC Nos. ME4936 and ME4937) Project stage: Other NOC-AE-11002730, Response to Request for Additional Information for License Renewal Application (TAC Nos. ME4936 and ME4937)2011-09-15015 September 2011 Response to Request for Additional Information for License Renewal Application (TAC Nos. ME4936 and ME4937) Project stage: Response to RAI NOC-AE-11002731, Response to Requests for Additional Information for License Renewal Application (TAC Nos. ME4936 and ME4937)2011-09-15015 September 2011 Response to Requests for Additional Information for License Renewal Application (TAC Nos. ME4936 and ME4937) Project stage: Response to RAI ML1124402012011-09-21021 September 2011 Request for Additional Information for the Review of the South Texas Project, Units 1 and 2 License Renewal Application - Aging Management Review, Set 2 (TAC Nos. ME4936, ME4937) Project stage: RAI ML11250A0432011-09-22022 September 2011 Requests for Additional Information for the Review of the South Texas Project, Units 1 and 2 License Renewal Application - Aging Management Review, Set 1 (TAC Nos. ME4936 and ME4937) Project stage: RAI ML11224A2652011-09-22022 September 2011 Aging Management Programs Audit Report Regarding the South Texas Project, Units 1 and 2, Station License Renewal Application (TAC Nos. ME4936 and ME4937) Project stage: Other ML11258A1612011-09-22022 September 2011 Request for Additional Information for the Review of the South Texas Project, Units 1 and 2 License Renewal Application - Aging Management Review, Set 3 (TAC Nos. ME4936 and ME4937) Project stage: RAI ML11272A1652011-10-0404 October 2011 Summary of Telephone Conference Call Held on September 28, 2011, Between the NRC and STP Nuclear Operating Company, Concerning Request for Additional Information Pertaining to the South Texas Project, LRA (TAC Nos. ME4936 and ME4937) Project stage: RAI NOC-AE-11002732, Response to Requests for Additional Information for the License Renewal Application2011-10-10010 October 2011 Response to Requests for Additional Information for the License Renewal Application Project stage: Response to RAI ML11273A0172011-10-11011 October 2011 Requests for Additional Information for the Review of the South Texas Project, Units 1 and 2, License Renewal Application - Aging Management Review, Set 5 (TAC Nos. ME4936 and ME4937) Project stage: RAI ML11273A0082011-10-11011 October 2011 Requests for Additional Information for the Review of the South Texas Project, Units 1 and 2, License Renewal Application - Aging Management Review, Set 4 (TAC Nos. ME4936 and ME4937) Project stage: RAI NOC-AE-11002737, Supplement to License Renewal Application (TAC Nos. ME4936 and ME4937)2011-10-18018 October 2011 Supplement to License Renewal Application (TAC Nos. ME4936 and ME4937) Project stage: Supplement ML11277A0472011-10-18018 October 2011 Requests for Additional Information for the Review of the South Texas Project, Units 1 and 2, License Renewal Application - Aging Management Program, Set 6 Project stage: RAI ML11305A0762011-10-25025 October 2011 Response to Requests for Additional Information for License Renewal Application (TAC ME4936 and ME4937) Project stage: Response to RAI NOC-AE-11002756, Contact Information Change, License Renewal Application (TAC ME4936 and ME4937)2011-10-26026 October 2011 Contact Information Change, License Renewal Application (TAC ME4936 and ME4937) Project stage: Other ML11318A1792011-11-0303 November 2011 Drawing No. LR-STP-WL-7R309F90021#2, Rev. 1, Piping and Instrumentation Diagram Liquid Waste Processing System Project stage: Other ML11318A1802011-11-0303 November 2011 Drawing No. LR-STP-WS-6R329F05048#1, Rev. 1, Piping and Instrumentation Diagram Solid Waste Processing System Project stage: Other ML11318A1762011-11-0303 November 2011 Drawing No. LR-STP-WL-7R309F05024#2, Rev. 1, Piping and Instrumentation Diagram Liquid Waste Processing System Project stage: Other ML11318A1652011-11-0303 November 2011 Drawing No. LR-STP-PS9Z329Z00047#1, Rev. 1, Piping and Instrumentation Diagram Primary Sampling System. Project stage: Other ML11318A1642011-11-0303 November 2011 Drawing No. LR-STP-PS-5Z329Z00045#2, Rev. 1, Piping & Instrumentation Diagram Primary Sampling System. Project stage: Other ML11318A1782011-11-0303 November 2011 Drawing No. LR-STP-WL-7R309F90021#1, Rev. 1, Piping and Instrumentation Diagram Liquid Waste Processing System Project stage: Other ML11318A1682011-11-0303 November 2011 Drawing No. LR-STP-RC-5R149F05004#2, Rev. 1, Piping and Instrumentation Diagram Acs Pressurizer Relief Tank. Project stage: Other ML11318A1722011-11-0303 November 2011 Drawing No. LR-STP-WL-5R309F05022#2, Rev. 1, Piping and Instrumentation Diagram Liquid Waste Processing System. Project stage: Other ML11318A1702011-11-0303 November 2011 Drawing No. LR-STP-RM-5R279F05033#2, Rev. 1, Piping & Instrumentation Reactor Makeup Water System. Project stage: Other ML11318A1602011-11-0303 November 2011 Drawing No. LR-STP-IA-8Q119F05050#2, Rev. 1, Piping & Instrumentation Diagram Mechanical Aux. Building Instrument Air. Project stage: Other ML11318A1472011-11-0303 November 2011 Drawing No. LR-STP-ED-5Q069F90011#1, Revision 1, Piping & Instrumentation Diagram Radioactive Vent and Drain System Fuel Handling Building Gravity Drains. Project stage: Other ML11318A1742011-11-0303 November 2011 Drawing No. LR-STP-WL-5R309F05027#2, Rev. 1, Piping & Instrumentation Diagram Auxiliary Steam and Condensate Return System (Lwps) Project stage: Other ML11318A1462011-11-0303 November 2011 Drawing LR-STP-ED-5Q069F05030 #2, Rev. 17, Piping & Instrumentation Diagram Radioactive Vent & Drain System Sump Pumps. Project stage: Other ML11318A1552011-11-0303 November 2011 Drawing No. LR-STP-FP-7Q272F00046, Rev. 1, Piping and Instrumentation Diagram Fire Protection Loop. Project stage: Other ML11318A1482011-11-0303 November 2011 Drawing No. LR-STP-ED-5Q069F90011#2, Revision 1, Piping & Instrumentation Diagram Radioactive Vent and Drain System Fuel Handling Building Gravity Drains. Project stage: Other 2011-06-16
[Table View] |
|
---|
Category:Conference/Symposium/Workshop Paper
MONTHYEARML22153A2942022-06-17017 June 2022 richardsd-hv-th28 ML16074A0412016-03-14014 March 2016 Summary of a Call Held on March 10, 2016, between USNRC and STPNOC, Concerning the Staff's Upcoming Audit Regarding the Amp for the Loss Of Material Due to Selective of Al-Br Welds in the ECW System for the STP LRA (TAC Nos. ME4936 And ME4937) ML15308A0112015-11-30030 November 2015 Record of Conference Call on STP Request for Additional Information Set 34 ML12312A2342012-11-13013 November 2012 Memo to File Summary Verbal Authorization Provided on 11/6/12 for Relief Request RR-ENG-3-10, RPV Head Flange O-Ring Leakoff Lines NDE, Third 10-Year Inservice Inspection Interval ML12261A3012012-09-21021 September 2012 Notice of Forthcoming Public Meeting Via Conference Call with STP Nuclear Operating Company to Discuss Risk-Informed GSI-191, Assessment of Debris Accumulation on Pressurized-Water Reactor (PWR) Sump Performance, Resolution Approach ML12080A0422012-04-19019 April 2012 STP - Record of Conference Call-02062012 on NRC-Mgt Concerns on Open Items ML12067A1272012-04-19019 April 2012 January 18, 2012, Summary of Telephone Conference Call Held Between the U.S. Nuclear Regulatory Commission and STP Nuclear Operating Company, Regarding Applicant Response Related to High-Strength Bolts, for the South Texas Project, Units 1 ML12047A2852012-02-29029 February 2012 January 17, 2012, Summary of Telephone Conference Call Held Between the U.S. Nuclear Regulatory Commission & STP Nuclear Operating Company, Concerning Requests for Additional Information Pertaining to the South Texas Project License Renewal ML1200901012012-01-10010 January 2012 Notice of Forthcoming Public Meeting Via Conference Call with South Texas Project Nuclear Operating Company ML11348A0392012-01-0404 January 2012 and 12/1/11, Summary of Telephone Conference Calls Between the U.S. Nuclear Regulatory Commission and STP Nuclear Operating Company, Concerning Requests for Additional Information Pertaining to the South Texas Project LRA - Set 9 ML11335A0762011-12-0606 December 2011 Summary of Telephone Conference Call Held on November 17, 2011, Between the U.S. Nuclear Regulatory Commission and STP Nuclear Operating Company, Concerning Clarifications to Some Responses to Requests for Additional Information - South Tex ML11320A1162011-12-0505 December 2011 November 9, 2011, Summary of Telephone Conference Call Held Between the U.S. Nuclear Regulatory Commission and STP Nuclear Operating Company, Concerning Requests for Additional Information Pertaining to the South Texas Project Units 1 and 2 ML1116402112011-06-24024 June 2011 Notice of Conference Call with STP Nuclear Operating Company to Discuss Risk-Informed GSI-191, Assessment of Debris Accumulation on Pressurized-Water Reactor (PWR) Sump Performance, Resolution Approach for South Texas, Units 1 & 2 ML11143A1662011-06-17017 June 2011 May 18, 2011, Summary of Telephone Conference Call Held Between the NRC and STP, Concerning Request for Additional Information Pertaining to the STP, LRA - SAMA RAI ML1109404772011-04-22022 April 2011 03/29/11 & 03/31/11 Summary of Telephone Conference Calls Held Between NRC and STP Nuclear Operating Company, Concerning Requests for Additional Information Pertaining to the South Texas Project, Units 1 and 2 License Renewal Application ML0805902832008-03-0606 March 2008 02/19-02/21/2008 Nrc/Doe Workshop Presentation: Life Beyond 60 - Sheppard 2022-06-17
[Table view] Category:Meeting Summary
MONTHYEARML22252A0432022-09-12012 September 2022 Summary of August 31, 2022, Webinar with STP Nuclear Operating Company to Discuss a Proposed LAR to Revise the Dose Consequence Analysis for Main Steam Line Break and Locked Rotor Analysis Events for STP, Units 1 & 2 ML22147A0932022-06-0606 June 2022 2021 Annual Assessment Public Meeting Summary ML21236A3082021-09-10010 September 2021 Regulatory Audit Summary Regarding License Amendment Request to Revise Moderator Temperature Coefficient Surveillance Requirements ML21222A1192021-08-12012 August 2021 Summary of Meeting with STP Nuclear Operating Company Regarding the License Amendment Request to Revise the Moderator Temperature Coefficient Surveillance Requirements for South Texas Project, Units 1 and 2 ML21140A3892021-05-24024 May 2021 Riv Column 1 EOC 2020 Public Meeting Summary ML20279A8152020-10-20020 October 2020 Summary of September 14, 2020, Presubmittal Teleconference with STP Nuclear Operating Company Regarding the Proposed LAR to Revise the Moderator Temperature Coefficient Surveillance Requirement for South Texas Project, Units 1 and 2 (EPID L ML20189A2832020-07-0707 July 2020 Summary of Region IV Annual Assessment Public Meeting ML20163A5522020-06-12012 June 2020 Summary of April 21, 2020, Teleconference with STP Nuclear Operating Company to Discuss the License Amendment Request to Revise the Emergency Plan for South Texas Project, Units 1 and 2 ML20140A2612020-05-27027 May 2020 May 5, 2020, Summary of Teleconference with STP Nuclear Operating Company to Discuss a Proposed Exigent License Amendment Request to Revise the Pressure of the Safety Injection Accumulators for South Texas Project, Unit 1 ML20107J5482020-04-15015 April 2020 Teleconference Regarding NRC Observations on the March 30, 2020, License Amendment Request to Revise the Emergency Plan STP Nuclear Operation Company South Texas Project, Units 1 and 2, Dockets 50-498 and 50-499 ML20049A0572020-02-26026 February 2020 Summary of February 6, 2020, Meeting with STP Nuclear Operating Company to Discuss a Proposed License Amendment Request to Revise the Emergency Plan for South Texas Project, Units 1 and 2 (EPID L- 2020-LRM-0004) ML19350C5902019-12-17017 December 2019 12/3/19, Summary of Teleconference with STP Nuclear Operating Company to Discuss a Proposed License Amendment Request to Revise the Emergency Plan for South Texas Project, Units 1 and 2, ML19102A0162019-04-16016 April 2019 4/10/2019 Summary of Public Teleconference Regarding Potential Submission of a Relief Request to Allow Use of Carbon Fiber Reinforced Polymer for Selected Piping Repairs at South Texas, Units 1 and 2 ML17005A1002017-01-18018 January 2017 January 4, 2017, Summary of Meeting to Discussion Stp'S Response to Request for Additional Information the Revised Aluminum Bronze Selective Leaching Aging Management Program for All Potentially Susceptible Welds Throughout the Facility ML16279A3312016-10-27027 October 2016 Summary of Public Meeting with STP Nuclear Operating Company Regarding Open Items, Risk-Informed Generic Safety Issue (GSI) 191 Application and Supplements for South Texas Project, Units 1 and 2 (CAC Nos. MF2400-MF2409) ML16272A4362016-10-14014 October 2016 Summary of Public Preapplication Meeting with STP Nuclear Operating Company to Discuss Possible License Amendment Request to Modify Emergency Response Organization for South Texas Project, Units 1 and 2 ML16246A0222016-10-0505 October 2016 Summary of Public Meeting with STP Nuclear Operating Company Regarding Open Items Related to Risk-Informed Generic Safety Issue (GSI) 191 Application and Supplements for South Texas Project, Units 1 and 2 (CAC Nos. MF2400 - MF2409) ML16238A5272016-09-0101 September 2016 Summary of 7/28/16, Public Meeting with STP Nuclear Operating Company to Discuss the License Amendment and Exemption Requests to Use a Risk-Informed Approach to the Resolution of GSI-191 (CAC Nos. MF2400 - MF2409) ML16218A3672016-08-30030 August 2016 07/21/2016 Summary of Public Teleconference Meeting with STP Nuclear Operating Company Discussing Revisions to License Renewal Application Aluminum Bronze Selective Leaching Aging Management Program and Background Document ML16236A0322016-08-23023 August 2016 08/18/2016 Summary of Conference Call With STP Nuclear Operating Company Concerning the Aluminum Bronze Selective Leaching Aging Management Program in the South Texas Project, License Renewal Application ML16236A3042016-08-23023 August 2016 08/11/2016 Summary of Conference Call Between NRC and STP Nuclear Operating Company Concerning the 2016 Annual Update to the South Texas Project License Renewal Application ML16180A0142016-07-25025 July 2016 Summary of Meeting Discussion Between South Texas Project, Units 1 and 2, and NRC Staff Regarding the Revised Aluminum Bronze Selective Leaching Aging Management Program for All Potentially Susceptible Welds Throughout the Facility ML16190A0082016-07-13013 July 2016 Summary of 6/22/2016 Public Meeting with STP Nuclear Operating Company Regarding Open Items, Risk-Informed Generic Safety Issue (GSI) 191 Application and Supplements for South Texas Project, Units 1 and 2 (CAC Nos. MF2400-MF2409) ML16188A0072016-07-0707 July 2016 Summary of Telecon Held on July 5, 2016 With STP Nuclear Operating Company, Concerning Additional Information Pertaining to the STP, License Renewal Application (TAC. Nos. ME4936, ME4937) ML16188A0112016-07-0707 July 2016 Summary of Telecon Held on July 5, 2016 With STP Nuclear Operating Company, Concerning Additional Information Pertaining to the STP, License Renewal Application (TAC Nos. ME4936, ME4937) ML16188A0092016-07-0707 July 2016 Summary of Telecon Held on July 5, 2016 with STP Nuclear Operating Company, Concerning Additional Information Pertaining to the STP, License Renewal Application (Tac. Nos. ME4936, ME4937) - Enclosure 1 ML16175A1082016-06-24024 June 2016 Summary of 4/21/2016 Public Meeting with STP Nuclear Operating Company Regarding Open Items, Risk-Informed Generic Safety Issue (GSI) 191 Application and Supplements for South Texas Project, Units 1 and 2 ML16166A0272016-06-14014 June 2016 Summary of Telephone Conference Call Held on 06/08/2016, Between the USNRC and STP Nuclear Operating Company Response to Request for Additional Information B2.1.18-6 Pertaining to the South Texas Project License Renewal Application ML16092A0852016-04-13013 April 2016 3/17/2016 Summary of Public Meeting with STP Nuclear Operating Company Regarding Open Items, Risk-Informed Generic Safety Issue (GSI) 191 Application and Supplements for South Texas Project, Units 1 and 2 (CAC Nos. MF2401-MF2409) ML16092A0442016-04-11011 April 2016 Summary of 3/3/2016 Public Meeting with STP Nuclear Operating Company Regarding Open Items, Risk-Informed Generic Safety Issue (GSI) 191 Application and Supplements for South Texas Project, Units 1 and 2 (CAC Nos. MF2400-MF2409) ML16088A2432016-04-0101 April 2016 2/18/2016, Summary of Public Meeting with STP Nuclear Operating Company Regarding Open Items, Risk-Informed Generic Safety Issue (GSI) 191 Application and Supplements for South Texas Project, Units 1 and 2 (CAC Nos. MF2400-MF2409) ML16081A2052016-03-24024 March 2016 Summary of Meeting with STP Nuclear Operating Company to Discuss Potential License Amendment Request for South Texas Project, Unit 1 Regarding Permanent Operation with 56 Control Rods ML16074A0412016-03-14014 March 2016 Summary of a Call Held on March 10, 2016, between USNRC and STPNOC, Concerning the Staff's Upcoming Audit Regarding the Amp for the Loss Of Material Due to Selective of Al-Br Welds in the ECW System for the STP LRA (TAC Nos. ME4936 And ME4937) ML16060A1272016-03-0707 March 2016 February 23, 2016, Summary of Conference Calls Held between NRC and STP Concerning Staff's Review of Submerged Closure Bolting Portion of 2014 Annual Update for STP License Renewal Application (TAC ME4936 And ME4937) ML16028A1522016-02-18018 February 2016 1/14/2016 Summary of Public Meeting with STP Nuclear Operating Company Regarding Modifications to the Licensee'S Risk-Informed Generic Safety Issue (GSI) 191 Application and Supplements for South Texas Project, Units 1 and 2 ML16035A4802016-02-12012 February 2016 Jsc Meeting Summary Attachment ML16011A0612016-02-0202 February 2016 Summary of 10/1/15 Meeting with STP Nuclear Operating Company to Discuss Revised Pilot Submittal and Request for Exemptions for a Risk-Informed Approach to Resolve Generic Safety Issue (GSI)-191 at South Texas Project, Units 1 and 2 (CAC MF ML16011A0702016-01-28028 January 2016 Summary of Preapplication Meeting with STP Nuclear Operating Company to Discuss Exigent License Amendment Request to Operate Following Removal of a D6 Control Rod at South Texas Project, Unit 1 ML16033A0072016-01-19019 January 2016 January 19, 2016, Summary of Public Meeting with STP to Discuss the Plant-Specific Aging Management Program, Selective Leaching of Aluminum Bronze, Associated with STP's License Renewal Application ML16013A0662016-01-14014 January 2016 Summary of 11/9 and 12/30/15 Conference Calls with STP Nuclear Operating Company to Discuss the Fall 2015 Steam Generator Tube Inspection Activities (CAC No. A11018) ML15308A0112015-11-30030 November 2015 Record of Conference Call on STP Request for Additional Information Set 34 ML15201A0032015-07-30030 July 2015 7/2/15 Summary of Meeting with STP Nuclear Operating Company to Discuss Revised Pilot Submittal and Request for Exemptions for a Risk-Informed Approach to Resolve Generic Safety Issue (GSI)-191 at South Texas, Units 1 and 2 ML15177A1042015-07-21021 July 2015 4/22/2015 Summary of Meeting with STP Nuclear Operating Company to Discuss Revised Pilot Submittal and Request for Exemptions for a Risk-Informed Approach to Resolve Generic Safety Issue (GSI)-191 at South Texas, Units 1 and 2 (TAC MF2400 t ML15177A2742015-07-21021 July 2015 5/6/2015 Summary of Meeting with STP Nuclear Operating Company to Discuss Revised Pilot Submittal and Request for Exemptions for a Risk-Informed Approach to Resolve Generic Safety Issue (GSI)-191 at South Texas, Units 1 and 2 (TAC Nos. MF24 ML15180A2732015-07-15015 July 2015 6/3/2015 Summary of Meeting with STP Nuclear Operating Company to Discuss Revised Pilot Submittal and Request for Exemptions for a Risk-Informed Approach to Resolve Generic Safety Issue (GSI)-191 at South Texas, Units 1 and 2 (TAC MF2400 to ML15139A3442015-06-11011 June 2015 Summary of Telephone Conference Call Held on May 12, 2015 Between the U.S. Nuclear Regulatory Commission and STP Nuclear Operating Company, Concerning Request for Additional Information, Set 31, Pertaining to the South Texas Project, Licens ML15103A0022015-05-13013 May 2015 Summary of 4/8/15 Meeting with STP Nuclear Operating Company to Discuss Revised Pilot Submittal and Request for Exemptions for a Risk-Informed Approach to Resolve Generic Safety Issue (GSI)-191 at South Texas, Units 1 and 2 ML15084A0032015-04-0606 April 2015 2/4/15 Summary of Meeting with STP Nuclear Operating Company to Discuss Revised Pilot Submittal and Request for Exemptions for a Risk-Informed Approach to Resolve Generic Safety Issue (GSI)-191 at South Texas, Units 1 and 2 (TAC MF2400-MF24 ML15084A0042015-04-0101 April 2015 2/5/2015 Summary of Presubmittal Meeting with STP Nuclear Operating Company to Discuss Integrated Leak Rate Testing Program License Amendment Request for South Texas, Units 1 and 2 ML15020A1062015-02-19019 February 2015 12/1-3/2014 Summary of Meeting with STP Nuclear Operating Company to Discuss Revised Pilot Submittal and Request for Exemptions for a Risk-Informed Approach to Resolve Generic Safety Issue (GSI)-191 at South Texas, Unit 1 and 2 (TAC MF2400- 2022-09-12
[Table view] Category:Request for Additional Information (RAI)
MONTHYEARML24024A1162024-01-24024 January 2024 STP Unit 2 Request for Information ML23334A0062023-11-29029 November 2023 NRR E-mail Capture - South Texas Project - Request for Additional Information - Proposed Alternative to ASME BPV Code Requirements ML23319A4442023-11-15015 November 2023 NRR E-mail Capture - South Texas Project - Draft Request for Additional Information - Proposed Alternative to ASME BPV Code Requirements ML23278A1532023-10-0505 October 2023 NRR E-mail Capture - South Texas Project Request for Additional Information - Request for Indirect Transfer of Licenses and Conforming Amendments (L-2023-LLM-0004) ML23264A0972023-09-21021 September 2023 NRR E-mail Capture - South Texas Project - Request for Additional Information - License Amendment Request to Revise the Alternate Source Term Dose Calculation (L-2023-LLA-0047) ML23255A2862023-09-12012 September 2023 NRR E-mail Capture - South Texas Project Draft Request for Additional Information License Amendment Request to Revise the Alternate Source Term Dose Calculation (L-2023-LLA-0047) ML23145A1872023-05-24024 May 2023 July 2023 Emergency Preparedness Program Inspection - Request for Information ML22255A1542022-09-13013 September 2022 Operating Company Information Request for the Cyber Security Baseline Inspection 05000498/2022401 and 05000499/2022401 ML22206A0142022-07-20020 July 2022 NRR E-mail Capture - South Texas Project - Request for Additional Information - 10 CFR 20.2002 Alternate Disposal Request ML22194A0502022-07-0707 July 2022 NRR E-mail Capture - South Texas Project - Updated Draft Request for Additional Information - 10 CFR 20.2002 Alternate Disposal Request ML22194A0492022-06-0808 June 2022 NRR E-mail Capture - South Texas Project - Draft Request for Additional Information - 10 CFR 20.2002 Alternate Disposal Request ML22123A3272022-05-0303 May 2022 STP EP Exercise Inspection July 2022 RFI ML22084A0762022-04-0404 April 2022 Notification of NRC Design Bases Assurance Inspection (Team) (05000498/2022012 and 05000499/2022012) and Request for Information ML21286A5732021-10-18018 October 2021 Notification of NRC Design Bases Assurance Inspection (Programs) (05000498/2022011 and 05000499/2022011) and Request for Information ML21166A2392021-06-16016 June 2021 Notification of Inspection (NRC Inspection Report 05000498/2021003 and 05000499/2021003) and Request for Information ML21160A1522021-06-0909 June 2021 Request for Information NRC Inspection 2021-003 Public Radiation Safety ML21133A2372021-05-0505 May 2021 Request for Additional Information: STP EP Exercise Inspection - July 2021 ML21039A8902021-02-0808 February 2021 NRR E-mail Capture - South Texas Project - Request for Additional Information - 1RE22 Inspection Summary Report for Steam Generator Tubing ML21029A3312021-01-29029 January 2021 NRR E-mail Capture - South Texas Project - Draft Request for Additional Information - 1RE22 Inspection Summary Report for Steam Generator Tubing ML20280A5452020-08-17017 August 2020 STP 2020 PIR Request for Information ML20111A0052020-04-17017 April 2020 NRR E-mail Capture - South Texas Project - Request for Additional Information - Proposed Alternative to ASME OM Code 2012 Edition - Relief Request PRR-01 ML20070N0222020-03-10010 March 2020 NRC Selection for Onsite Review ML20057G4612020-02-26026 February 2020 05000498/499 Request for Information - Occupational Radiation Safety Inspection ML20045E2172020-02-13013 February 2020 Licensed Operator Positive Fitness-For-Duty Test ML20036F5862020-02-0404 February 2020 Request for Additional Information - Proposed Alternative to ASME Code Requirements for the Repair of Essential Cooling Water System Class 3 Buried Piping (EPID L-2019-LLR-0096)Redacted ML19165A1032019-06-14014 June 2019 NRR E-mail Capture - Draft RAI for STP TS 3.8.1.1 Sbdg SR Change ML19081A1512019-03-21021 March 2019 NRR E-mail Capture - Draft Round 2 RAI - Sbdg Voltage and Frequency LAR (L-2018-LLA-0078) ML18283B9522018-10-10010 October 2018 NRR E-mail Capture - Final RAI - South Texas Standby DG TS Change (L-2018-LLA-0078) ML18263A1432018-09-12012 September 2018 NRR E-mail Capture - Final RAI for South Texas Project RR-ENG-E-16 (L-2018-LLR-0097) ML18197A4172018-07-17017 July 2018 Notification of NRC Triennial Heat Sink Performance Inspection (05000498/2018003 and 05000499/2018003) and Request for Information ML18003B4222018-01-0303 January 2018 NRR E-mail Capture - Final Request for Additional Information Amendment Request to Modify the Emergency Response Organization for South Texas Project ML17229B4672017-08-16016 August 2017 Notification of NRC Inspection 05000499/2017008 and Request for Information ML17132A0712017-05-15015 May 2017 Information Request the Cyber Security Baseline Inspection, Notification to Perform Inspection 05000498/2017407; 05000499/2017407 ML17103A6272017-04-13013 April 2017 Notification of Evaluations of Changes, Tests, and Experiments Inspection (05000498/2017007 and 05000499/2017007) and Request for Information ML16351A1502016-12-16016 December 2016 Correction Letter Closeout of Request for Information Questions That Are No Longer Applicable Associated with the Resolution of Generic Safety Issue 191 (CAC Nos. MF2400 - MF2409) ML16302A4532016-12-12012 December 2016 Closeout of Request for Additional Information Questions That Are No Longer Applicable, Resolution of Generic Safety Issue (GSI) 191 (CAC Nos. MF2400-MF2409) ML16343A0422016-12-0808 December 2016 Request for Additional Information for the Review of the South Texas Project, Units 1 and 2 License Renewal Application (CAC NOS. ME4936, ME4937) ML16340A1022016-12-0505 December 2016 Requests for Additional Information for the Review of the South Texas Project License Renewal Application (CAC Nos. ME4936 and ME4937) ML16246A0952016-09-15015 September 2016 Correction to 8/26/16 Request for Additional Information Enclosure, License Amendment Request to Revise Technical Specification 5.3.2 to Allow Operation with 56 Full-Length Control Rod Assemblies ML16214A2912016-08-26026 August 2016 Summary of June 28-30, 2016, Regulatory Audit at Westinghouse in Rockville, MD, License Amendment Request to Revise Technical Specification 5.3.2 to Allow Operation with 56 Full-Length Control Rod Assemblies ML16187A0522016-07-0707 July 2016 Request for Additional Information Regarding License Renewal Application ML16141B0812016-05-31031 May 2016 Audit Summary, Risk Audit on April 12-13, 2016, at Alumni Center at the University of Texas, Austin, Tx; Pilot Generic Safety Issue 191 Submittal and Exemption Request, and Draft Request for Additional Information ML16125A2902016-05-26026 May 2016 Request for Additional Information, Risk Review, Exemption and License Amendment Request for a Risk-Informed Approach to Resolve Generic Safety Issue (GSI)-191 (CAC Nos. MF2400-MF2409) ML16127A4522016-05-12012 May 2016 Supplemental Information Needed for Acceptance of Requested Licensing Action, Amendment Request to Revise Technical Specification 5.3.2 to Allow Operation with 56 Full-Length Control Rod Assemblies ML16104A3522016-04-22022 April 2016 Requests for Additional Information Set 35 for the Review of the South Texas Project License Renewal Application (Tac Nos. ME4936, ME4937) ML16082A5072016-04-11011 April 2016 Request for Additional Information, Phased Response Requested, Exemption and License Amendment Request for a Risk-Informed Approach to Resolve Generic Safety Issue (GSI)-191 (CAC Nos. MF2400-MF2409) ML16082A4842016-03-22022 March 2016 NRR E-mail Capture - South Texas Project Units 1 & 2, Draft Request for Additional Information for Risk Review for GSI-191 ML16081A0042016-03-18018 March 2016 NRR E-mail Capture - South Texas Project Units 1 & 2, Draft Request for Additional Information for Thermal-hydraulic Review for GSI-191 ML16053A1872016-03-0101 March 2016 Request for Additional Information, Request to Revise Technical Specification 6.8.3.j, Containment Leakage Rate Testing Program, to Extend Integrated Leak Rate Test Interval from 10 to 15 Years (CAC MF6176-MF6177) ML16060A2872016-02-29029 February 2016 NRR E-mail Capture - Request for Additional Information - STP LRA Safety Review 2024-01-24
[Table view] |
Text
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 November 30, 2015 LICENSEE: STP Nuclear Operating Company FACILITY: South Texas Project
SUBJECT:
SUMMARY
OF CONFERENCE CALLS HELD ON OCTOBER 15 AND 27, 2015 BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION AND STP NUCLEAR OPERATING COMPANY, CONCERNING SET 34, REQUEST FOR ADDITIONAL INFORMATION FOR THE SOUTH TEXAS PROJECT, LICENSE RENEWAL APPLICATION (TAC. NOS. ME4936 AND ME4937)
The U.S. Nuclear Regulatory Commission (NRC or the staff) and representatives of STP Nuclear Operating Company (STPNOC or the applicant) held a telephone conference call on October 15, 2015, and a follow-on call on October 27, 2015, to discuss and clarify the staffs requests for additional information (RAIs), Set 34, concerning the South Texas Project, license renewal application. The discussions were useful in clarifying the intent of the staffs RAIs. provides the participants and Enclosure 2 contains the RAIs discussed with the applicant, including a brief description on the status of the items.
The applicant had an opportunity to comment on this summary.
/RA/
John W. Daily, Senior Project Manager Reactor Projects Branch 1 Division of License Renewal Office of Nuclear Reactor Regulation Docket Nos.: 50-498 and 50-499
Enclosures:
- 1. List of Participants
- 2. List of Requests for Additional Information cc: Listserv
ML15308A011 Publicly Available Non-Publicly Available Sensitive Non-Sensitive To receive a copy of this document, indicate in the concurrence box C = Copy without attach/encl, E = Copy with attach/encl, N = No copy
- Concurred via e-mail OFFICE LA:DLR* PM:RPB1:DLR* BC:RPB1:DLR PM:RPB1:DLR*
NAME YEdmonds JDaily YDiaz-Sanabria JDaily DATE 11/ 19 /15 11/ 20 /15 11/ 25 /15 11/ 30 /15 TELEPHONE CONFERENCE CALL, RAI SET 34 SOUTH TEXAS PROJECT LICENSE RENEWAL APPLICATION LIST OF PARTICIPANTS OCTOBER 15, 2015 PARTICIPANTS AFFILIATIONS John Daily Nuclear Regulatory Commission (NRC)
Jim Medoff NRC Ganesh Cheruvenki NRC Bill Holston NRC Arden Aldridge STP Nuclear Operating Company (STPNOC)
Gary Warner Worley Parsons Cheryl Boggess Westinghouse Karli Szweda Westinghouse Taylor Terek Westinghouse Mary Ann Walsh Westinghouse LIST OF PARTICIPANTS (FOLLOW-ON CALL FOR B2.1.13-5a)
OCTOBER 27, 2015 PARTICIPANTS AFFILIATIONS John Daily NRC Bill Holston NRC Arden Aldridge STPNOC Gary Warner Worley Parsons ENCLOSURE 1
CONFERENCE CALL ON REQUEST FOR ADDITIONAL INFORMATION RAI SET 34 LICENSE RENEWAL APPLICATION OCTOBER 15 AND 27, 2015 The U.S. Nuclear Regulatory Commission (NRC or the staff) and representatives of STP Nuclear Operating Company (STPNOC or the applicant) held a telephone conference call on October 15, 2015, and a follow-on call on October 27, 2015, to discuss and clarify the staffs requests for additional information (RAIs), Set 34, concerning the South Texas Project, license renewal application. The discussions were useful in clarifying the intent of the staffs RAIs.
Discussion The staff and the applicant held discussions on the draft RAIs contained in RAI Set 34 in order to clarify and ensure a common understanding of the information being requested. The issues, requests, and pertinent discussions are presented below.
The follow-on call was conducted on October 27, 2015, to finish discussion of RAI B2.1.13-5a.
The staff agreed to look further into some of the points raised as presented below, prior to issuing the final version of the requests. Actions or changes agreed to in the call, or resolved shortly thereafter, are presented as part of the respective RAIs discussion.
The applicant agreed to take the staffs concerns into consideration as it prepares its responses.
Individual RAI drafts RAI 3.0.3.3.6 Components within the scope of the AMP Issue:
The population of components in MRP-227-A includes Primary, Expansion, Existing Program and No Additional Measures category components, even though No Additional Measures components are not included as part of the sample of components that will be inspected in accordance with the MRP-227-A methodology. The Scope of Program program element for the PWR Reactor Internals Program does not include No Additional Measures components as part of the population of components that is included within the scope of the AMP. The methodology in MRP-227-A does not preclude the possibility that the some components identified as No Additional Measures components in MRP-227-A are ASME Section XI Examination Category B-N-2 or B-N-3 components for the STP units.
Request:
Justify the basis for omitting No Additional Measures components from the scope and population of components in the PWR Reactor Internals Program. Clarify whether any of the RVI No Additional Measures components at STP are defined as ASME Section XI Examination Category B-N-2 or B-N-3 components. If so, identify which No Additional ENCLOSURE 2
Measures components are within the scope of the ASME Section XI Examination Category B-N-2 or B-N-3 requirements, and clarify whether the components will be inspected in accordance with the ASME Section XI Inservice Inspection, Subsections IWB, IWC, and IWD Program (LRA AMP B2.1.1).
Discussion:
The staff and the applicant agreed that no additional clarification was needed.
RAI 3.0.3.3.6 Apparent component categorization inconsistencies Issue:
In MRP-227-A, the EPRI MRP identifies XL lower core plates in Westinghouse-designed PWR as Existing Program components that are inspected in accordance with ASME Section XI Examination Category B-N-3 requirements and does not define these components as Expansion components. To be consistent with this protocol, the reactor vessel internals inspection plan (RVIIP), as submitted in the letter of June 30, 2015, identifies that the XL lower core plates are Existing Program components that will be inspected in accordance with ASME Section XI Examination Category B-N-3 requirements. Thus, there is an apparent inconsistency between the category identified for the XL lower core plates in the Scope of Program element and the category for these components identified in the RVIIP.
Request:
Clarify whether the XL lower core plates (one plate in each unit) are Expansion components or Existing Program components for the PWR Reactor Internals Program, or both. If the plates are Expansion components, identify and justify the basis for selecting the Primary components that are linked to the XL lower core plates as Expansion components for the AMP and the RVIIP.
Discussion:
The staff and the applicant agreed that no additional clarification was needed.
RAI 3.0.3.3.6 Response to A/LAI #1 - Lack of an MRP Letter 2013-025 Assessment Issue:
The letter of June 30, 2015, does not include an assessment of the three parameters identified by Westinghouse for bounding RVI component design, as recommended in MRP Letter No.
2013-025.
Request:
Provide the basis why the response basis to A/LAI #1 in the letter of June 30, 2015, did not include an assessment of the three parameters identified above, in accordance with
recommendations in EPRI MRP Letter No. 2013-025. Justify why such an assessment would not be needed as part of the basis for concluding that the assumptions used to develop MRP-227-A are bounding for the design of the RVI components at STP Units 1 and 2.
Discussion:
The staff and the applicant agreed that no additional clarification was needed.
RAI 3.0.3.3.6 Topic - Response to A/LAI #2 - Comparison to UFSAR Information Issue:
In Section 4.1 of the UFSAR, the applicant identifies RVI design assembly or component modifications that have been or will be implemented in the units. Based on the UFSAR statements, the staff need to understand: (a) whether the specific RVI assemblies at STP include any design configurations that deviate from the RVI design assemblies and assembly components that were generically evaluated in the MRP-191, MRP-232, and MRP-227-A reports or were not evaluated in these reports, and (b) whether these deviations (if they exist) should have been more definitively assessed in the response that was provided to A/LAI #2.
Apparent deviations for lower core support structure components are addressed in RAI 3.0.3.3.6-5.
Request:
Identify all RVI design assembly component configurations (other than those for the deviations on lower core support structure assembly components) that have not been evaluated by or differ from those generically evaluated in the MRP-191, MRP-232, and MRP-227-A reports, other than those for lower core support assembly components (which are the topic of RAI 3.0.3.3.6-5).
For components that have corresponding components in the generic MRP evaluations but differ from the configurations in the generic evaluation, clarify how the stress levels and neutron fluences for these components compare to those assessed for corresponding components in the generic MRP design evaluations. Based on this comparison, justify why augmented inspection protocols for the components would not need to be proposed for the components on a plant-specific basis for the AMP. Similarly, for components not analyzed in the MRP reports, justify why plant-specific aging management criteria would not need to be proposed for the components on a plant-specific basis for the AMP.
Discussion:
The staff and the applicant agreed that no additional clarification was needed.
RAI 3.0.3.3.6 Topic - Response to A/LAI #2 - Lower Core Support Assembly Deviations Issue:
These deviations were not identified in the response to A/LAI #2 and change a number of generic Primary to Expansion category relationships for the RVIIP from those defined in the MRP-227-A report for these Westinghouse-designed internal
Request:
Justify why the response to A/LAI #2 has not identified the lack of a lower core support structure assembly and lower core support column bodies and bolts (MRP-227-A Expansion components) as a deviations from the assessments in the MRP-191, MRP-232, and MRP-227-A reports. Clarify how these deviations would change the Primary to Expansion category relationships that need to be defined for the AMP and RVIIP when compared to those normally defined in the MRP-227-A report for Westinghouse-designed internals. Provide the basis why alternative Expansion component substitutions for these components would not need to be proposed for the AMP and RVIIP in order to be consistent with the total number of Expansion components defined in MRP-227-A for Westinghouse-designed internals.
Discussion:
The staff stated that it found apparent conflicting statements concerning the design of the STP core barrels and lower support structure assemblies; the staff noted these could create deviations from the generic Westinghouse PWR-designed components as reflected in MRP-227-A. The applicant agreed to supply a justification that explains why the components designs are not deviations from the MRP-227-A report.
RAI 3.0.3.3.6 Topic - Response to A/LAI #3 - Use of Inspection Data for CRGT Split Pins Issue:
- 1. The EPRI MRP has yet to identify in MRP-227-A or in the background reports for MRP-227-A that augmented inspections are part of the programmatic criteria for managing cracking or wear in replaced Westinghouse-design CRGT split pins made from Type 316 cold-worked stainless steel materials or that such data will be collected by the EPRI MRP for distribution to and evaluation by the industry licensee. Thus, some additional information is needed to clarify how the applicant will implement its process for collecting and assessing CRGT split pin inspection data in accordance with the PWR Reactor Internals Program.
- 2. If the CRGT splits pins are defined as ASME Section XI Examination Category B-N-3 removable core support structure components, the applicant will be required to inspect the components in accordance with their ISI program requirements for B-N-3 inspections, independent of the position taken in MRP-227-A for replaced split pins made from Type 316 cold-worked stainless steel materials.
Request:
- 1. Identify the plants that will be performing inspections of their replaced Type 316 cold-worked CRGT split pins which the applicant will use as the lead operating experience for managing aging in the CRGT split pins at STP Units 1 and 2. Identify the process or processes that will be used in accordance with the Administrative Controls or Confirmation Process elements of the PWR Reactor Internals Program to collect and compile the inspection data from these plants.
Identify the criteria that will be implemented in accordance with the monitoring and trending
program element of the AMP. Identify the plant-specific acceptance criteria that will be used to assess such data and the corrective actions that will be taken if the acceptance criteria are not met.
- 2. Clarify whether the replaced CRGT split pins at STP are categorized as ASME Section XI Examination Category B-N-3 components (i.e., ASME removable core support structure components). If the split pins are defined as ASME removable core support structure components, justify why the components would not need to be inspected and managed for aging using either the Existing Program criteria in the PWR Reactor Internals Program (LRA B.2.1.35) or the ASME Section XI Inservice Inspection, Subsections IWB, IWC, and IWD Program (i.e., the ISI Program in LRA Section B2.1.1).
Discussion:
The staff and the applicant agreed that no additional clarification was needed.
RAI 3.0.3.3.6 Topic - Response to A/LAI #5 - Comparison to UFSAR Information Issue:
In UFSAR Section 4.1, the applicant discusses changes to the configuration of the hold-down springs which eliminated the use of screws for retention of the springs.
Request:
Clarify whether the change in the component configuration for the hold-down springs (as described in UFSAR Section 4.1) impacts the loading and FMECA assessments for Type 403 martensitic stainless steel hold-down springs in the MRP-191 report. Based on this review, clarify whether the basis for omitting physical measurements of the hold-down springs remains valid in light of the information provided about the hold-down spring design in Section 4.1 of the UFSAR. Justify your response to this RAI.
Discussion:
The staff and the applicant discussed the 2 types of hold-down springs, the one for the internals package as a whole and the ones for individual fuel assembly bundles. Since the internals package hold-down spring has no associated screws or bolts, this RAI is not necessary and will be dropped.
RAI 3.0.3.3.6 Topic - Response to A/LAI #7 -Thermal Aging of CASS Upper Internals Issue:
The response to A/LAI #7 uses the criteria in NRC License Renewal Issue 08-0030 (dated May 19, 2000) as the basis for concluding that thermal aging embrittlement will not be an aging management issue for RVI upper internals assembly support columns or column bases.
Additional data is necessary to verify that thermal aging embrittlement will not be an aging mechanism of concern for these components during the period of extended operation.
Request:
Provide the plant-specific delta-ferrite contents for the CASS CF8 materials used to fabricate upper internals assembly support columns or column bases, and the equational criteria and plant specific chemistry alloy content data used to calculate the delta-ferrite contents of these components. As an alternative basis for resolving this issue (if applicable), the applicant may demonstrate that these components were appropriately evaluated in MRP-227-A or the background reports for MRP-227-A and were placed into FMECA Category A and No Additional Measures categories based on the conclusions that there are no consequences on RVI component intended functions if these components fail to maintain their structural integrity.
Discussion:
The staff and the applicant agreed that no additional clarification was needed.
RAI 3.0.3.3.6 Topic - Response to A/LAI #8, Item 5 - RVI Environmentally-Assisted Fatigue Issue:
Although the scope of LRA AMP B3.1 includes activities to monitor the impacts of environmentally-assisted fatigue on the CUF analyses for reactor coolant pressure boundary components, it is not evident whether similar activities will be applied to the CUF analyses for the RVI components listed in the background section of this RAI, and if so, how such activities will be applied to the cycle counting and CUF reanalysis criteria defined in the AMP.
Request:
Clarify whether the AMPs monitoring and trending activities for monitoring the impacts of environmental effects of the adequacy of components with CUF analyses are being extended to those RVI components with a CUF analysis. If not, identify the activities that will be performed to analyze or manage environmentally-assisted fatigue in the RVI components. Justify the response to this RAI.
Discussion:
The staff and the applicant agreed that no additional clarification was needed.
RAI 3.0.3.3.6 Topic - Adequacy of UFSAR Supplement Section A1.35 Issue:
In the letter of June 30, 2015, the applicant did not administratively update LRA Section A1.35, PWR Reactor Internals, to be consistent with the updated version of the PWR Reactor Internals Program (LRA Section B2.1.35) provided in the letter of June 20, 2015. Thus, the current version of LRA UFSAR Supplement Section A1.35, PWR Vessel Internals, is out of date and must be updated to reflect the status of the AMP and reactor vessel internals inspection plan (RVIIP) that were submitted in the letter of June 30, 2015.
Request:
Justify why LRA Section A1.35 has not been updated to reflect that the current status of the AMP and RVIIP submitted in the letter of June 30, 2015. Specifically, justify why the USFAR supplement in Section A1.35 has not been updated to reflect the following aspects of the program:
- Appropriate referenced ERPI Report for the AMP and UFSAR Supplement for the AMP is EPRI Technical Report No. 1022863, Materials Reliability Program: Pressurized Water Reactor Internals Inspection and Evaluation Guideline (MRP-227-A)
- Protocols and activities for implementing the AMP and RVIIP in accordance with methodology in MRP-227-A are appropriately adjusted to account for deviations from the generic design and inspection and evaluation criteria in MRP-227-A or for the applicants response bases for resolving specific Applicant/Licensee Action Items in the MRP-227-A report, as identified in the NRC safety evaluation for MRP-227-A dated December 16, 2011
- Population of components in the AMP include Primary, Expansion, Existing Program, and No Additional Measures category components for the AMP Discussion:
The staff and the applicant agreed that no additional clarification was needed.
RAI B2.1.35-11/B3.1 This RAI is a duplicate request to RAI 3.0.3.6-9 and therefore is deleted.
RAI B2.1.13-5a - Topic - LR-ISG-2013 Inspection Frequency Followup Issue:
(1) LR-ISG-2013-01, Aging Management of Loss of Coating or Lining Integrity for Internal Coatings/Linings on In-Scope Piping, Piping Components, Heat Exchangers, and Tanks, AMP XI.M42, Internal Coatings/Linings for In-Scope Piping, Piping Components, Heat Exchangers, and Tanks, recommends that when peeling, delamination, blisters, or rusting are observed during inspections or when cracking and flaking that does not meet acceptance criteria is observed during inspections, the subsequent inspection interval is 4 years instead of 6 years.
The responses to RAI 3.0.3-2a Part (d) and RAI B2.1.13-5a state that the specific degraded coatings will be replaced. However, with a known degradation mechanism potentially occurring in other locations with the same coating and environment, the staff concluded that inspections should be conducted more frequently than if no degradation was noted in prior inspections. The staff lacks sufficient information to conclude that a 6-year inspection interval is adequate when the extent of coating degradation, similar to the observed degradation that was repaired, is not known. In addition, an adequate basis for inspecting the EW pump internal coatings every 10 years was not provided.
And:
(2) The extent of blistering, peeling, and delamination is not typically detectable by visual inspection alone. The corrective actions program element of LR-ISG-2013-01, Aging Management of Loss of Coating or Lining Integrity for Internal Coatings/Linings on In-Scope Piping, Piping Components, Heat Exchangers, and Tanks, AMP XI.M42, Internal Coatings/Linings for In-Scope Piping, Piping Components, Heat Exchangers, and Tanks, recommends that testing or examination be conducted to ensure that the extent of repaired coatings/linings encompasses sound material.
Request:
- 1) Respond to the following:
a) With the exception of the internal coatings for the fire water storage tanks, state and justify the basis for how the extent of coatings that could be experiencing similar degradation to the coating areas that were repaired will be determined in a reasonable time frame.
b) State the basis for inspecting the EW pump internal coatings every 10 years in lieu of every 6 years.
c) State the basis for not stating the periodicity of EW pump internal coating inspections in the Open-Cycle Cooling Water System Program.
- 2) State whether: (a) testing and examination will be conducted prior to and during the repair to ensure that replaced coatings encompasses sound coating material; and (b) the testing will include physical techniques in addition to visual examination.
Discussion:
The issues as originally presented in the draft were agreed to be clear. Most of the discussion centered upon various aspects of the staff requests.
Request 1(a): The applicant stated that it inspects one train of ECW components each year (6 trains between the two units combined), thus the combination of component, coating, and environment is inspected annually. In addition the applicant stated that when degradation is detected, it is repaired to original condition.
Requests 1(b) and 1(c):
The applicant stated that it does not credit the EW pump internal coating with a license renewal function (i.e., it is not relied upon for pressure boundary retention), however the coating is covered under the 10-year pump overhaul schedule. The staff stated that, in that case, could the coating, while not in-scope, nevertheless become a clogging hazard to downstream components? The applicant stated that it credits the downstream self-cleaning strainers which have a mesh size smaller than the minimum diameter of any downstream in-scope components.
Request 2:
Discussion of this item revolved around sub part (b), with the applicant stating that it repairs all degradation that is found during inspections. Therefore, the staff and the applicant agreed that sub part (b) is not needed and can be dropped.
Following the October 15 call, the staff revised Issue 3/Request 3. A follow-on call was held on October 27, 2015, to discuss the revisions.
[Issue 3]:
Although the ECW pumps are located upstream of self-cleaning strainers, this in and of itself is not a sufficient basis to justify a nominal 10-year inspection frequency. The staff lacks sufficient information to conclude that the strainers will provide an effective barrier to flow blockage of downstream heat exchangers. Plant-specific operating experience of the ECW coatings has revealed degraded coatings. Degraded coatings can lead to loss of material of the base material. A basis was not provided for how loss of material will be monitored given that the coatings will be inspected on a nominal 10-year frequency.
[Request 3]:
State:
- a. What backup indications are available to determine that fouling is not occurring on the self-cleaning strainers.
- b. State the interval of inspection of the strainer elements on the self-cleaning strainers.
- c. State the results of a plant-specific review of strainer differential pressure results.
[Finally,] Given that prior plant-specific inspections of the ECW pump internal coatings have revealed degradation, state the basis for why there is reasonable assurance that the pressure boundary function of the pump and associated piping components will be maintained between inspection intervals.
During the October 27 call, the applicant explained that the ECW pump strainer has a control room alarm on high-DP, and operators routinely check on the strainer during their rounds. In addition, the applicant stated that the strainer is maintained under its Maintenance Rule programs and is inspected at a 3-year interval for holes and other issues. The applicant stated that it manages loss of material by the periodic overhaul of the pumps. The staff sought confirmation that the ECW pumps are constructed of aluminum bronze material, which is generally corrosion resistant. The applicant confirmed this to be the case and stated this had been provided in an earlier response; the staff agreed to look into the earlier responses to verify this, and if so, then requests 3(c) and the final paragraph would be dropped as not needed.
SUBJECT:
SUMMARY
OF CONFERENCE CALLS HELD ON OCTOBER 15 AND 27, 2015 BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION AND STP NUCLEAR OPERATING COMPANY, CONCERNING SET 34, REQUEST FOR ADDITIONAL INFORMATION FOR THE SOUTH TEXAS PROJECT, LICENSE RENEWAL APPLICATION (TAC. NOS. ME4936 AND ME4937)