Summary of Conference Call with STP Nuclear Operating Company Concerning the Aluminum Bronze Selective Leaching Aging Management Program in the South Texas Project, License Renewal Application
ML16236A032
Person / Time
Site: South Texas  STP Nuclear Operating Company icon.png
Issue date: 08/23/2016
From: Lois James
Division of License Renewal, License Renewal Projects Branch 1
To: Gerry Powell
South Texas
Lois James, 301-415-3306
References
TAC ME4936, TAC ME4937
Download: ML16236A032 (6)


Text

James, Lois From:

James, Lois Sent:

Tuesday, August 23, 2016 9:49 AM To:

gtpowell@STPEGS.COM Cc:

James, Lois; Diaz-Sanabria, Yoira K; Tran, Tam; Holston, William; Homiack, Matthew; Hovanec, Christopher; Morey, Dennis; McIntyre, David; Regner, Lisa; Taylor, Nick; Proulx, David; Janicki, Steven; Money, Shawn; Sanchez, Alfred; Hernandez, Nicholas; Maier, Bill; Dricks, Victor; Pick, Greg; Graves, Samuel; Aldridge, Arden J; 'Gonzales, Rafael'; Sterling, Lance; Murray, Michael; RidsNrrDlr Resource; RidsNrrDlrRpb1 Resource; RidsNrrDlrRerb Resource; RidsNrrDlrRarb Resource; RidsNrrDlrRasb Resource; RidsNrrDlrRsrg Resource; RidsNrrPMSouthTexas Resource; RidsOgcMailCenter Resource; Wentzel, Michael

Subject:

SUMMARY

OF A CONFERENCE CALL HELD ON AUGUST 18, 2016, BETWEEN THE NRC AND STPNOC, CONCERNING THE ALUMINUM BRONZE SELECTIVE LEACHING AGING MANAGEMENT PROGRAM IN THE SOUTH TEXAS PROJECT, LICENSE RENEWAL APPLICATION (TAC. NOS. ME4936 AND ME4937)

Attachments:

Summary of Conference Call on August 18, 2016, re clarification to Al-Brz Selective Leaching AMP - enclosure 1.pdf; Summary of Conference Call on August 18, 2016, re clarification to Al-Brz Selective Leaching AMP - enclosure 2.pdf UNITEDSTATES NUCLEARREGULATORYCOMMISSION WASHINGTON,D.C.205550001 August 23, 2016 LICENSEE: STP Nuclear Operating Company FACILITY: South Texas Project

SUBJECT:

SUMMARY

OF A CONFERENCE CALL HELD ON AUGUST 18, 2016, BETWEEN THE U.S.

NUCLEAR REGULATORY COMMISSION AND STP NUCLEAR OPERATING COMPANY, CONCERNING THE ALUMINUM BRONZE SELECTIVE LEACHING AGING MANAGEMENT PROGRAM IN THE SOUTH TEXAS PROJECT, LICENSE RENEWAL APPLICATION (TAC.

NOS. ME4936 AND ME4937)

The U.S. Nuclear Regulatory Commission (NRC or the staff) and representatives of STP Nuclear Operating Company (STPNOC or the applicant) held a telephone conference call on August 18, 2016, to clarify changes made to Aluminum Selective Leaching Aging Management Program as amended by letter dated July 28, 2016 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML16221A391).

provides a listing of the participants and Enclosure 2 contains a listing of the items discussed with the applicant, including a brief description on their status.

The applicant had an opportunity to comment on this summary.

Lois M. James, Sr. Project Manager Projects Branch 1

ML16236A032 *concurrence via email OFFICE PM:RPB1:DLR RARB:DLR PM:RPB1:DLR BC:RPB1:DLR PM:RPB1:DLR NAME LJames WHolston*

MWentzel*

YDiaz-Sanabria LMJ for LJames DATE 8/22/2016 8/23/2016 8/23/2016 8/23/2016 8/23/2016

TELEPHONE CONFERENCE CALL SOUTH TEXAS PROJECT LICENSE RENEWAL APPLICATION LIST OF PARTICIPANTS AUGUST 18, 2016 PARTICIPANT AFFILIATION Lois M. James U.S. Nuclear Regulatory Commission (NRC)

William Holston NRC Christopher Hovanec NRC Brian Allik NRC Arden Aldridge South Texas Project Nuclear Operating Rafael Gonzales STPNOC Rob Engen STPNOC Richard Kersey STPNOC Russ Cipolla Intertek Gary Warner Worley Parsons

ENCLOSURE 2

SUMMARY

OF TELEPHONE CONFERENCE CALL SOUTH TEXAS PROJECT LICENSE RENEWAL APPLICATION AUGUST 18, 2016 The U.S. Nuclear Regulatory Commission (NRC or the staff) and representatives of South Texas Project (STP) Nuclear Operating Company (STPNOC or the applicant) held a telephone conference on August 18, 2016, to clarify changes made to Aluminum Selective Leaching Aging Management Program (AMP) as amended by letter dated July 28, 2016 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML16221A391).

Background:

By letter dated October 25, 2010 (Accession No. ML103010256), the applicant submitted a License Renewal Application (LRA) pursuant to Title 10 of the Code of Federal Regulations (CFR) Part 54 for review by the U.S. Nuclear Regulatory Commission (NRC or the staff), to renew operating licenses NPF-76 and NPF-80 for South Texas Project, Units 1 and 2, for an additional 20 years.

By letter dated July 28, 2016, the applicant amended the plant-specific AMP which addresses selective leaching of aluminum bronze. The revisions to the program were based on a public meeting that was held between the NRC staff and the applicant on June 21, 2016 (ADAMS Package Accession No. ML16180A015), and a telephone conference held on July 5, 2016 (ADAMS Package Accession No. ML16188A012).

Discussion:

1. Modification to the Corrective Actions Program Element of the Selective Leaching of Aluminum Bronze Program The staff noted that the corrective actions program element of the Selective Leaching of Aluminum Bronze Program was modified by letter dated July 28, 2016 (ADAMS Accession No. ML16221A391). Specifically, the staff noted that the corrective actions program element does not state the specific corrective actions that will be taken if the results of a structural integrity evaluation are not acceptable. The staff recognizes that a structural integrity evaluation will be performed if: (a) there is a through-wall leak of an above or below ground weld; (b) an aluminum bronze weld is found to have an indication that does not meet acceptance criteria; or (c) a destructive examination does not meet acceptance criteria. The structural integrity evaluation is performed in order to confirm that the load carrying capacity of the welds that are still in-service remain adequate to support the intended function of the essential cooling water (ECW) system.

The staff stated that a generic reference to entering the failure of the structural integrity evaluation in corrective action program was insufficient detail for the staff to reach a conclusion that reasonable assurance that the ECW system will meet its intended function exists. The staff suggested that appropriate corrective actions could be but are not limited to shortening the duration between visual inspections and addressing functionality of a header if a leaking weld is detected. No conclusions or clarifications were reached during this discussion. The staff and the applicant agreed to potentially hold a separate telecom on this question.

2. Modification to the Acceptance Criteria for Destructive Examinations The staff noted that the Selective Leaching of Aluminum Bronze AMP acceptance criteria program element was revised by letter dated July 28, 2016 (ADAMS Accession No. ML16221A391) to state, in part, that:

The acceptance criterion for destructive examinations is no loss of material due to selective leaching penetrating 80% of the root-pass region and non-propagating* (surrounded by a resistant phase distribution). The microstructure of the weld root region exhibits a non-continuous phase distribution consistent with the metallurgical technical basis report.

Further, the staff noted that the Selective Leaching of Aluminum Bronze AMP corrective actions program element states, in part, that when, [a] destructive examination does not meet acceptance criteria. Perform five additional destructive examinations until no unacceptable selective leaching is found to assess extend of condition and cause.

Based on the information provided, the staff stated that it is unclear if the acceptance criteria for destructive examinations includes phase distribution. The corrective actions and expansion criteria associated with not meeting the phase distribution acceptance criteria are also unclear. The staff stated that an appropriate phase distribution was central to demonstrating that the root pass of welds is less susceptible to selective leaching.

The applicant agreed to integrate the words phase distribution into the AMP.

3. Modification to the Parameters Monitored and Inspected Program Element of the Selective Leaching of Aluminum Bronze Program The staff noted that the parameters monitored and inspected program element of the Selective Leaching of Aluminum Bronze program was revised by letter dated July 28, 2016 (ADAMS Accession No. ML16221A391) to state that the welds subject to volumetric examination will be selected based on, construction and size distributions. Further, the staff noted this program element also states that the welds subject to destructive examination will be randomly selected.

The staff requested clarification on the basis for not providing a reason for why the welds subject to destructive examination would be randomly selected. Parameters that could impact the susceptibility of the final weld properties should be considered.

The applicant agreed to revise the AMP to address the selection of welds to be destructively examined.

4. Components in the Scope of Program Program Element of the Selective Leaching of Aluminum Bronze Program The staff noted that Enclosure 1 of the letter dated July 28, 2106 (ADAMS Accession No. ML16221A391), describes how the extruded tee weld repair sizes will be characterized.

However, the scope of program program element of the Selective Leaching of Aluminum Bronze program does not include how the extruded tee weld repair sizes will be characterized. The staff requested clarification.

The applicant stated that the AMP would be include a description of how the extruded tee weld repair sizes will be characterized under the scope of program program element.

5. Modification to the Detection of Aging Effects Program Element of the Selective Leaching of Aluminum Bronze Program The staff noted that the detection of aging effects program element was modified by letter dated July 28, 2016 (ADAMS Accession No. ML16221A391) to require that a volumetric examination be conducted to determine if loss of material or cracking has occurred in the vicinity of degraded coatings on buried ECW piping. The volumetric examinations is also cited in Commitment No. 39. The staff requested clarification on how loss of material due to selective leaching will be detected by volumetric inspections. In addition, the staff noted that there is no acceptance criteria for the extent of loss of material due to selective leaching of the external surfaces of buried ECW piping.

The applicant stated that it understood the clarification and would revise the program element.

6. Consistency between the UFSAR Supplement and Selective Leaching of Aluminum Bronze Program The staff noted that LRA Section A1.37 was modified by letter dated July 28, 2016 (ADAMS Accession No. ML16221A391) to state that visual inspections will be conducted every six months, not to exceed nine months. The staff further noted that LRA Section B2.1.37 states that visual inspections will be conducted every six months. The staff requested clarification on this inconsistency.

The applicant stated that it understood the clarification and would revise the program element.