ML12227A560

From kanterella
Jump to navigation Jump to search

Summary of Telephone Conference Call Held on August 9, 2012, Between NRC and STPNOC, Concerning Clarification of One Part of Response to RAI 4.3-13. Pertaining to the STP, Units 1 and 2, LRA
ML12227A560
Person / Time
Site: South Texas  
(NPF-076, NPF-080)
Issue date: 09/12/2012
From: Daily J
License Renewal Projects Branch 1
To:
South Texas
Daily J, 415-3873
References
TAC ME4936, TAC ME4937
Download: ML12227A560 (5)


Text

~"p. REGu(

UNITED STATES o,~~~'-

"/'>-°11...

NUCLEAR REGULATORY COMMISSION t!!

(1 WASHINGTON, D.C. 20555-0001

<If 0

\\

I September 12, 2012 V-

~

~"

~o

        • 1<

LICENSEE:

STP Nuclear Operating Company FACILITY:

South Texas Project, Units 1 and 2

SUBJECT:

SUMMARY

OF TELEPHONE CONFERENCE CALL HELD ON AUGUST 9, 2012, BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION AND SOUTH TEXAS PROJECT NUCLEAR OPERATING COMPANY, CONCERNING CLARIFICATION OF ONE PORTION OF THE RESPONSE TO RAI4.3-13, PERTAINING TO THE SOUTH TEXAS PROJECT, UNITS 1 AND 2, LICENSE RENEWAL APPLICATION (TAC NOS. ME4936 AND ME4937)

The U.S. Nuclear Regulatory Commission (NRC or the staff) and representatives of South Texas Project Nuclear Operating Company (STPNOC or the applicant) held a telephone conference call on August 9, 2012, to discuss clarification of one portion of the applicant's response to Request for Additional Information (RAI) 4.3-13, for the South Texas Project, Units 1 and 2, license renewal application (LRA). The telephone conference call was useful in clarifying the response to the RAI. provides a listing of the participants and Enclosure 2 contains a summary of the discussion.

The applicant had an opportunity to comment on this summary.

John Daily, Senior Project Ma ager Projects Branch 1 Division of License Renewal Office of Nuclear Reactor Regulation Docket Nos. 50-498 and 50-499

Enclosures:

As stated cc w/encls: Listserv

TELEPHONE CONFERENCE CALL SOUTH TEXAS PROJECT LICENSE RENEWAL APPLICATION LIST OF PARTICIPANTS August 9, 2012 PARTICIPANTS AFFI LlATIONS John Dailv U.S. Nuclear Reaulatorv Commission (NRC)

Allen Hiser I NRC OnYee NRC Arden Aldridae STP Nuclear Operatina Comoanv (STPNOC)

Ken Taplett STPNOC Dave Gerber

! Structurallntearitv Associates ENCLOSURE 1

SUMMARY

OF TELEPHONE CONFERENCE CALL FOR CLARIFICATION OF ONE PORTION OF THE RESPONSE TO RAI4.3-13, PERTAINING TO THE SOUTH TEXAS PROJECT, UNITS 1 AND 2, LICENSE RENEWAL APPLICATION August 9, 2012 The U.S. Nuclear Regulatory Commission (NRC or the staff) and representatives of South Texas Project Nuclear Operating Company (STPNOC or the applicant) held a telephone conference call on August 9, 2012, to discuss clarification of one portion of the applicant's response to Request for Additional Information (RAI) 4.3-13, for the South Texas Project, Units 1 and 2, license renewal application (LRA). The telephone conference call was useful in clarifying the response to the RAI.

Discussion The staff noted that the applicant, in its response to RAI 4.3-13 by letter dated November 21, 2011, stated concerning Transient 11 and its associated stress fatigue: "... Transient 11 number of cycles is beyond the endurance limit of the ASME fatigue curves... " (page 41 of 103) When compared to the American Society of Mechanical Engineers (ASME) fatigue curve, the staff was unable to determine the meaning of the applicant's statement. The staff and the applicant discussed this in order for the staff to obtain clarification as to the applicant's intended response.

The applicant stated that the intent of the statement was to read as follows: liThe stress range of Transient 11 is below the endurance limit of the ASME fatigue curves, therefore this transient is not significant to fatigue." The applicant also stated that it did not believe that the LRA required changing because table 4.3.2 lists the transient and the current footnote for transient 11 in Table 4.3.2 appeared to be adequate. The staff agreed to this position.

The staff agreed with the clarification and stated that it would reference this record of conference call, as necessary, in its evaluation of the issue for the Safety Evaluation with Open Items.

ENCLOSURE 2

September 12, 2012 LICENSEE:

STP Nuclear Operating Company FACILITY:

South Texas Project, Units 1 and 2

SUBJECT:

SUMMARY

OF TELEPHONE CONFERENCE CALL HELD ON AUGUST 9, 2012, BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION AND SOUTH TEXAS PROJECT NUCLEAR OPERATING COMPANY, CONCERNING CLARIFICATION OF ONE PORTION OF THE RESPONSE TO RAI 4.3-13, PERTAINING TO THE SOUTH TEXAS PRO~IECT, UNITS 1 AND 2, LICENSE RENEWAL APPLICATION (TAC NOS. ME4936 AND ME4937)

The U.S. Nuclear Regulatory Commission (NRC or the staff) and representatives of South Texas Project Nuclear Operating Company (STPNOC or the applicant) held a telephone conference call on August 9, 2012, to discuss a clarification of one portion of the applicant's response to Request for Additional Information (RAI) 4.3-13, for the South Texas Project, Units 1 and 2, license renewal application (LRA). The telephone conference call was useful in clarifying the response to the RAI. provides a listing of the participants and Enclosure 2 contains a summary of the discussion.

The applicant had an opportunity to comment on this summary.

IRA!

John Daily, Senior Project Manager Projects Branch 1 Division of License Renewal Office of Nuclear Reactor Regulation Docket Nos. 50-498 and 50-499

Enclosures:

As stated cc w/encls: Listserv DISTRIBUTION: See next page ADAMS Accession No. IVIL12227 A560

  • concurred via email OFFICE LA: RPB 1 : DLR*

PM:RPB1 :DLR BC:RPB1 :DLR PM:RPB1 :DLR NAME YEdmonds

~IDaily DMorey JDaily DATE 8/16/12 8/28/12 9/11/12 9/12/12 OFFICIAL RECORD COpy

Memorandum to STP Nuclear Operating Company from J. Daily dated September 12, 2012

SUBJECT:

SUMMARY

OF TELEPHONE CONFERENCE CALL HELD ON AUGUST 9, 2012, BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION AND SOUTH TEXAS PROJECT NUCLEAR OPERATING COMPANY, CONCERNING CLARIFICATION OF ONE PART OF RESPONSE TO RAI4.3-13, PERTAINING TO THE SOUTH TEXAS PROJECT. UNITS 1 AND 2. LICENSE RENEWAL APPLICATION (TAC NOS. ME4936 AND ME4937)

DISTRIBUTION:

HARDCOPY:

DLR RF E-MAIL:

PUBLIC RidsNrrDlr Resource RidsNrrDlrRpb1 Resource RidsNrrDlrRpb2 Resource RidsNrrDlrRerb Resource RidsNrrDlrRpob Resource RidsNrrDraApla Resource RidsOgcMailCenter JDaily TTran AHiser OYee DMclntyre. OPA BSingal. DORL

\\N\\Nalker, RIV JDixon, RIV BTharakan, RIV WMaier, RIV VDricks, RIV NOKeefe, RIV AVegel, RIV GPick, RIV